KoKo Fit Club - Marlin Design Build · 2012-09-28 · Location/Key Plan Scale : N.T.S. 1 A0.1...

5
Location/Key Plan Scale : N.T.S. 1 A0.1 RENOVATED TENANT SPACE - (shown cross hatched) 7412 Creedmoor Rd.. - Proposed tenant space for new KoKo Fitclub EXISTING BUILDING SITE - Wake County Gis Pin # 0797582288 - no alteration on exterior of building or site North EXISTING BUILDING - allowable area calculations on sheet A1.0 are based upon this area. Existing Parking Creedmoor Rd. Harris Teeter Bridgeport Dr. Stonehenge Dr. Ladd Family Martial Arts Harris Teeter Suntan City Debby's Hallmark Unleashed - the Dog & Cat Store The Barbershop Nail Castle Outdoor Bird KoKo Fitclub Orchid Japanese Restaurant Gigi's Boutique Orchid Japanese Restaurant Wine n' Things Building Key Plan Overall Building - building as listed on Appendix B (shown shaded), based upon information available on Wake County GIS website Scale : N.T.S. DRAWING INDEX ARCHITECTURAL A0.1 Cover Sheet, Location / Key Plan, Drawing Index A1.0 Code Summary - Appendix "B" A1.1 Life Safety Plan A2.0 First Floor Plan, Schedules, Wall Types, Interior Finishes A2.1 Ceiling Plan, Interior Casework Details KoKo Fit Club Up-fit for Stonehenge Market OWNER/TENANT: KoKo Fit Club CONTRACTOR: Marlin Design/Build ARCHITECT: John L. Harvey Architecture + Design, Inc. Hillsborough, NC 27278 MEP ENGINEERING: Maple Engineering, PLLC, Raleigh, NC 27605 Sam Mobley A 0.1 Cover Sheet, Key Plan, Drawing Index 12038 Sept. 25, 2012 Permit Set © JLH Architecture + Design, Inc. expressly reserves its common law copyright & other property rights in these plans. These plans are not to be reduced, changed or copied in any form or matter whatsoever, nor are they to be assigned to any third party without first obtaining the expressed written permission & consent of JLH Architecture + Design, Inc. Sheet Title: Sheet Number: Date: Project: Revisions No. / Description / Date This sheet is formatted for a 24" x 36" print. If this print does not measure that - refer to the graphic scale. john l. harvey Architecture + Design, Inc. 2128 Old Forest Drive Hillsborough, NC 27278 office: (919) 883-1966 cell: (919) 323-1473 email: [email protected] www.harveyarchitecture.com KoKo Fitclub New Upfit - Stonehenge Market 7428 Creedmoor Road Raleigh, North Carolina 27613 1 Revised per review comments 5/21/2012

Transcript of KoKo Fit Club - Marlin Design Build · 2012-09-28 · Location/Key Plan Scale : N.T.S. 1 A0.1...

Page 1: KoKo Fit Club - Marlin Design Build · 2012-09-28 · Location/Key Plan Scale : N.T.S. 1 A0.1 RENOVATED TENANT SPACE - (shown cross hatched) 7412 Creedmoor Rd..- Proposed tenant space

Location/Key PlanScale : N.T.S.

1A0.1

RENOVATED TENANT SPACE - (shown cross hatched)7412 Creedmoor Rd.. - Proposed tenant space for newKoKo Fitclub

EXISTING BUILDING SITE - Wake County Gis Pin #0797582288 - no alteration on exterior of building or site

North

EXISTING BUILDING - allowable area calculations onsheet A1.0 are based upon this area.

ExistingParking

Creedm

oor Rd.

HarrisTeeter

Bridgeport Dr.

Stonehenge Dr.

Ladd FamilyMartial Arts

Harris TeeterSuntan CityDebby's HallmarkUnleashed - the Dog & Cat StoreThe BarbershopNail Castle

Outdoor Bird

KoKo Fitclub

Orchid Japanese RestaurantGigi's BoutiqueOrchid Japanese Restaurant

Wine n' Things

Building Key Plan

Overall Building - building as listed onAppendix B (shown shaded), basedupon information available on WakeCounty GIS website

Scale : N.T.S.

DRAWING INDEX ARCHITECTURAL A0.1 Cover Sheet, Location / Key Plan, Drawing Index A1.0 Code Summary - Appendix "B" A1.1 Life Safety Plan A2.0 First Floor Plan, Schedules, Wall Types, Interior Finishes A2.1 Ceiling Plan, Interior Casework Details

KoKo Fit ClubUp-fit for Stonehenge Market

OWNER/TENANT: KoKo Fit ClubCONTRACTOR: Marlin Design/BuildARCHITECT: John L. Harvey Architecture + Design, Inc.Hillsborough, NC 27278MEP ENGINEERING: Maple Engineering, PLLC, Raleigh,NC 27605

Sam Mobley

A 0.1

Cover Sheet, KeyPlan, DrawingIndex

12038

Sept. 25, 2012

Permit Set

©JL

H A

rchi

tect

ure

+ D

esig

n, In

c. e

xpre

ssly

rese

rves

its

com

mon

law

cop

yrig

ht &

oth

er p

rop

erty

rig

hts

in th

ese

pla

ns. T

hese

pla

ns a

re n

ot to

be

red

uced

, cha

nged

or c

opie

d in

any

form

or m

att

er w

hats

oeve

r, no

r are

they

to b

e as

signe

d to

any

third

par

ty w

ithou

t firs

t obt

aini

ng th

e ex

pres

sed

writ

ten

perm

issio

n &

con

sent

of J

LH A

rchi

tect

ure

+ D

esig

n, In

c.

Sheet Title:

Sheet Number:

Date:

Project:

Revisions

No. / Description / Date

This sheet is formatted for a24" x 36" print. If this printdoes not measure that -

refer to the graphic scale.

john l. harveyArchitecture + Design, Inc.

2128 Old Forest DriveHillsborough, NC 27278office: (919) 883-1966cell: (919) 323-1473email:[email protected]

www.harveyarchitecture.com

Ko

Ko

Fit

clu

bN

ew U

pfit

- S

ton

ehen

ge

Mar

ket

74

28 C

ree

dm

oor

Road

Ra

leig

h,

No

rth C

aro

lina 2

7613

1 Revised perreview comments

5/21/2012

Click t

o buy NOW!

AcroPlot Pro

w

ww.cadzation.com Click t

o buy NOW!

AcroPlot Pro

www.cadzation.com

Page 2: KoKo Fit Club - Marlin Design Build · 2012-09-28 · Location/Key Plan Scale : N.T.S. 1 A0.1 RENOVATED TENANT SPACE - (shown cross hatched) 7412 Creedmoor Rd..- Proposed tenant space

CITY OF RALEIGHBUILDING CODE SUMMARY

FOR ALL COMMERCIAL PROJECTSNC 2012 BUILDING CODE

(EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)(Reproduce the following data on the building plans sheet 1 or 2.)

Name of Project: __KoKo Fit Club__________________________________________________________________Address: __7428 Creedmoor Road, Raleigh NC 27613__________________________Suite #:____________Owner or Authorized Agent: __Britt Spivey Phone: (919) 796-6405Email: [email protected]____________________ Fax: ______________________________Owned By: Privately City/CountyStateCode Enforcement Jurisdiction: City CountyCity/CountyName of Jurisdiction: City of Raleigh

PROJECT SUMMARY: The space is currently vacant and the tenant would like to up-fit the space intoa B occupancy for a new KoKo Fitclub franchise.

Building Description: Existing 1 story shopping center IIB construction– no change in building shell orstructure

Scope of Work: Tenant will rework the entire existing space to include new reception space, exercisearea, dressing room, and restroom. New walls, ceiling tile, casework, equipment, toilet fixtures, lightfixtures, mechanical diffusers, and exercise equipment will be installed.

Code Compliance Summary: Upfit to be B occupancy

Alternative Means of Compliance Request:

LEAD DESIGN PROFESSIONAL: John HarveyDESIGNER FIRM NAME LICENSE # TELEPHONE # E-MAILArchitectural JLH Architecture + Design, Inc. John Harvey 9918 (919) 883-1966 [email protected] __N/A______________ ____________ ____________ (____)_______ ______________Electrical Maple Engineering, PLLC Zack Tomlin 037509 (919) 341-4247 [email protected] Alarm __N/A______________ ____________ ____________ (____)_______ ______________Plumbing Maple Engineering, PLLC Zack Tomlin 037509 (919) 341-4247 [email protected] l Maple Engineering, PLLC Zack Tomlin 037509 (919) 341-4247 [email protected] N/A_____________ ____________ ____________ (____)_______ ______________Structural __N/A______________ ____________ ____________ (____)_______ ______________Retaining Walls >5' High __N/A_______ ____________ ____________ (____)_______ ______________Other __N/A______________ ____________ ____________ (____)_______ ______________

Note: Special Inspections and Inspectors to be listed at end of this document.

Building Code: 2012 North Carolina State Building Code (NCSBC)

2009 North Carolina State Building Code (NCSBC)

2006 North Carolina State Building Code (NCSBC)

2009 NC Rehab 2006 NC Rehab

2009 Chapter 34 (Attach Summary) 2006 Chapter 34 (Attach Summary)

1995 Existing Building Code Volume 9

New Building: New Building Shell Building First Time Interior Completion

Addition Alteration to Shell

Accessibility Compliance Form (when applicable)

Existing Building: Renovation Interior Completion Tenant Alteration Reconstruction Repair Alteration to Shell Change of Use Tenant Space Change of Occupancy

Note: Zoning Review May Be Required for Change of Use or Occupancy

Original Occupancy: ______________

Proposed Occupancy: _ B- Business_______________

OCCUPANCY INFORMATIONPrimary Occupancies: Assembly: A-1 A-2 A-3 A -4 A-5

Business Educational Factory-Industrial: F-1 F-2High-Hazard: H-1 H-2 H-3 H-4 H-5Institutional: I-1 I-2 I-3 I-4

I-3 USE CONDITION: 1 2 3 4 5 Mercantile Residential: R-1 R-2 R-3 R-4

Storage: S-1 S-2 High-piledS-1 SPECIAL CONDITION : Repair Garage (406.6)S-2 SPECIAL CONDITION -- Parking Garage: Open (406.3) Enclosed (406.4)

Utility and MiscellaneousOther Uses:

Accessory Uses (Indicate Percentages): _ _____________Incidental Uses: __________________________________________________________________

Special Occupancies: 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421

Group A motion picture (507.10); Malls (507.11); and H-2 aircraft paint hangers (507.8).4 Maximum Building Area = total number of stories in the building x E but not greater than 3 x E.5 The maximum area of parking garages must comply with 406.3.5. The maximum area of air traffic control towersmust comply with 412.1.2.

ALLOWABLE HEIGHT

MOST RESTRICTIVE USE(GROUP )

ALLOWABLE HEIGHT(TABLE503)

INCREASE FOR SPRINKLERS SHOWN ON PLANS CODEREFERENCE

Type of Construction Type _IIB Type _IIB_ Table 601

Building Height in Feet H = _55_ ft H + 20 ft = _75_ ft H = 25 ft Table 503Building Height in Stories S = _2___ S + 1 = _3___ S = 1 Table 503

BUILDING DATATHIS SECTION REQUIRED FOR ALL PROJECTS

Construction Type: I -A I-B II-A II-B III-A III-B IV-HT V-A V-B

Mixed construction: No Yes Types _____________________________Sprinklers: No Yes NFPA 13 NFPA 13R

Partially Sprinklered Special SuppressionStandpipes: No Yes Class: I II III Wet DryFire District: No Yes (Appendix D) Flood HazardBuilding Height: _25_ Feet _1__ StoryBasement: No YesMezzanine: No YesHigh Rise: No Yes Life Safety Plan Sheet # (if provided): __A1.1_______________

Gross Building Area:FLOOR EXISTING (SQ FT) NEW (SQ FT) SUB-TOTALBasement

Ground Floor 32,760 (2,023 Tenant) 0 32,760

(2,023 Tenant)Mezzanine2nd Floor 3rd Floor 4th Floor

TOTAL 32,760 (2,023 Tenant)

0 32,760 (2,023 Tenant)

Area of Project Tenant/Alteration/Renovation: ____Existing Tenant Space 2,023 s.f._____________Area of Construction: ______2,023 s.f.____________________________________________________

FIRE PROTECTION REQUIREMENTSTHIS SECTION REQUIRED FOR ALL PROJECTS

Life Safety Plan Sheet #, if Provided A1.1 - no change to the existing building shell

RATI NGBUILDINGELEMENT

FIRESEPARATION

DISTANCE(FEET)

R EQ'D* PROVIDED(W/____ HR*REDUCTION)

DETAIL #AND

SHEET #

DESIGN #FOR

RATEDASSEMBLY

DESIGN # FORRATED

PENETRATION

DESIGN#FOR

RATEDJOINTS

Bearing walls Exterior

North 30 0 N/C

East 30 0 N/CWest 30 0 N/CSouth 30 0 N/C

Interior Bearing Walls 0 N/CNonbearing walls Exterior

North 30 0 N/C

East 30 0 N/C

West 30 0 N/CSouth 30 0 N/C

Interior Non Bearing Walls 0 N/CStructural frame, includingcolumns, girders, trusses 0 N/C

Floor construction, includingsupporting beams and joists. Listconstruction type.

0 N/C

Floor Ceiling Assembly 0 N/C

Columns Supporting Floors 0 N/C

Roof construction, includingsupporting beams and joists ** 0 N/C

Roof Ceiling Assembly 0 N/C

Columns Supporting Roof 0 N/C

Shafts – Exit Enclosures 0 N/CShafts – Other (describe) 0 N/CShafts – Other (describe) 0 N/CCorridor Separation 0 N/COccupancy Separation 0 N/CParty/Fire Wall Separation 0 N/CIncidental Use Separation 0 N/CDwelling/Sleeping unit Separation 0 N/CSmoke Barrier Separation 0 N/CTenant Separation 0 N/C

* Indicate section number permitting reduction** Indicated if using Table 601 Note C exception

PERCENTAGE OF WALL OPENING CALCULATIONSTHIS SECTION FOR ADDITIONS, NEW AND CHANGE OF USE

Allowable openings per Table 704.8 No LimitFire separation distance is greater than 30’

WALL LEGENDSTHIS SECTION REQUIRED FOR ALL PROJE CTS

CHECK IF THE FOLLOWING ARE PRESENT AND INDICATE BY A WALL LEGEND ON ALL PLANS Fire Par titions 708 Fire Walls 705 Fire Barriers 706 Smoke Partitions 710 Smoke Barr iers 709 Shaft Enclosure 707

LIFE SAFETY SYSTEM REQUIREMENTSTHIS SECTION REQUIRED FOR ALL PROJE CTS

Emergency Lighting: No YesExit Signs: No YesFire Alarm: No YesSmoke Detection Systems: No YesPanic Hardware: No Yes

EXIT REQUIREMENTSNUMBER AND ARRANGEMENT OF EXITS

THIS SECTION REQUIRED FOR ALL PROJE CTSSEE SHEET A1.1

MINIMUM2

NUMBER OF EXITSTRAVEL DISTANCE ARRANGEMENT MEANS OF

EGRESS1,3 (SECTION 1015.2)FLOOR, ROOMAND/O R SPACEDESIGNATION REQUIRED SHOWN ON

PLANSALLOWABLE

TRAVEL DISTANCE(TABLE 1015.1)

ACTUAL TRAVELDISTANCESHOWN ON

PLANS

REQUIREDDISTANCEBETWEEN

EXIT DOORS

ACTUALDISTANCESHOWN ON

PLANS

FIRSTFLOOR

1 3 300’ 53’ N/A N/A

1 Corridor dead ends (Section 1017.3)2 Single exits (Section 1015.1; Section 1019.2)3 Common Path of Egress Travel (Section 1014.3)

OCCUPANT LOAD AND EXIT WIDTHTHIS SECTION REQUIRED FOR ALL PROJECTS

SEE SHEET A1.1(a) (b) (a b) (c) EXIT WIDTH (in)2,3,4,5

EGRESS WIDTHPER OCCUPANT(TABLE1005.1)

REQUIRED WIDTH(SECTION 1005.1)

(a b) x c

ACTUAL WIDTHSHOWN ON PLANS

USE GROUP

AND/OR SPACEDESI GNATION

AREA1

SQ. FT.AREA1

PEROCCU-PANT

NUMBEROF

OCCU-PANTS

STAIR LEVEL STAIR LEVEL STAIR LEVEL

EXERCISE

SPACE1,500 50 30 .15 4.5” 36”

STORAGE 280 300 1 .15 .15 36”TOTAL 31

1 See Table 1004.1.1 to determine whether net or gross area is applicable.2 Minimum stairway width (Section 1009.1); min. corridor width (Section 1017.2); min. door width (Section 1008.1.1)3 Minimum width of exit passageway (Section 1021.2)4 The loss of 1 means of egress shall not reduce the available capacity to less than 50 percen t of the total required (Section 1005.1)5 Assembly occupancies (Section 1025)

ASSEMBLY OCCUPANCY INFORMATIONTHIS SECTION FOR ASSEMBLY USE AREA(S)

Space Area - SF Occupant Occupant Exit ExitDescription Load Factor Load Width Quantity__B_____ __1,500__ _Existing _31____ _36” min._ 1 ExistingTOTAL___31 occupants__

PLUMBING FIXTURE REQUIREMENTSTHIS SECTION REQUIRED FOR ALL PROJECTS

See sheet A 1.1 for more information on square footage per occupancy

BUILDINGDRAIN SIZE

NUMBER OFBUILDINGDRAINS

TOTALFIXTURE UNIT

LOAD

WATERSERVICE SIZE

NUMBER OFWATER

SERVICES

TOTALFIXTURE

UNIT LOAD

NOTES

WATERCLOSETS LAVATORIES DRINKING FOUNTAINSOCCUPANCYMALE FEM ALE

URINALSMALE FEMALE

SHOWERS/TUBS REGULAR ACCESSIBLE

Storage - 329 s.f.1 occupantBusiness - 392 s.f.4 occupantsA-3 - 1010 s.f.20 occupantsTotal Occupants for

plumbing - 251 Unisex 0 1 0 0 0

Total Required 1 0 1 0 0 0Total Provided 1 Unisex 0 1 0 0 0

Structural Design Loads

1Structure Conforms to "Conventional Light Frame Provisio ns of 2308 __Yes, continue __No , Go to Line 9

2 Roof Live Load = PSF

3 Floor Live Load = PSF

4 Ground Snow Load (Pg) = PSF

5 Basic Wind Speed, 3 sec. Gust = MPH

6 Seismic Site Class =7 Seismic Design Category =8 Go to Line 449 Live Loads Area

10 Floor Live Load (indicate area) = PSF11 Floor Live Load (indicate area) = PSF

12 Floor Live Load (indicate area) = PSF

13 Live Load Reduction used in Design Yes No

14 Roof Live Load = PSF15 Roof Snow Load Data16 Flat-Roof Snow Load (Pf) = PSF

17 Snow Exposure Factor (Ce) =

18 Snow Importance Factor (Is) =19 Thermal Facto r (Ct) =

20 Wind Design Data

21 Basic Wind Speed, 3 sec. Gust = MPH

22 Wind Importance Factor (Iw) =23 Wind Exposure (If multiple exposures are used indicate directions)

24 Internal Pressure Coefficient

25 Componen ts and Cladding Loads =(If elements are not designed by the registered designprofessional)

26 Wind Base Shear, Wx KIPS27 Wind Base Shear, Wyx KIPS

28 Earthquake Design Data

29 Seismic Important Factor (Ie) =

30 Occup ancy Category31 Mapped Spectral Response Acceleration Ss

32 Mapped Spectral Response Acceleration S1

33 Site Class (Pro vid e soils report if Site Class is n ot "D")

34 Spectral Response Coefficient, Sds =35 Spectral Response Coefficient, Sd1 =

36 Seismic Design Category =

37 Buildin g (Structural) System

38 Basic Seismic Force Resisting Sy stem39 Seismic Response Coefficient (Cs) =

40 Response Modification Factor, R =

41 Analysis Procedure Used =42 Seismic Base Shear, Sx KIPS43 Seismic Base Shear, Sy KIPS44 Soil Data

45 Presumptive Soil Bearing Pressure = PSF46 Bearing Pressure per Soils Report PSF47 Deep Foundation Type48 Deep Foundation Allowable Loads TONS, downward49 Uplift KIPS50 Lateral KIPS

ACCESSIBLE PARKING

LOT OR PARKINGAREA

TOTAL # OF PARKING SPACES # OF ACCESSIBLE SPACES PROVIDED TOTAL #ACCESSIBLEPROVID ED

REQUIRED PROVIDED REGULAR WITH 5'ACCESS AISLE

VAN SPACES WITH 8'ACCESS AISLE

TOTAL NO CHANGE IN EXISTING PARKING

SPECIAL APPROVALS

(Describe special approvals from local jurisdictions, County or State Departmen t of Health, NC Department ofInsurance, International Code Council, etc.)

_____________________________________________________________________________________________

_____________________________________________________________________________________________

ENERGY SUMMARYTHIS SECTION FOR NEW, ADDITIONS CHANGE OF USE, AND INTERIOR COMPLETION

ENERGY REQUIREMENTS:The following data shall be considered minimum and any special attribute required to meet the energy codeshall also be provided. Each Designer shall furnish the required portions of the project information for theplan data sheet. If energy cost budget method, state the annual energy cost budget vs. allowable annualenergy cost budget.

THERMAL ENVELOPE

Method of Compliance:Prescriptive Performance Energy Cost Budget

Roof/ceiling Assembly (each assembly)Description of assembly ____________________________________________________________________________________________________

U-Value of total assembly __________________________R-Value of insulation ________________________Skylights in each assembly

U-Value of skylight __________Total square footage of skylights in each assembly ____________

Exterior Walls (each assembly)Description of assembly ____________________________________________________________________________________________________

U-Value of total assembly __________________________R-Value of insulation ________________________Openings (windows or doors with glazing)

U-Value of assembly _____________________Shading coefficient ______________________Projection factor ________________________Low-e required, if applicable _______________

Door R-Values________________________________________________

Walls adjacent to unconditioned space (each assembly)Description of assembly ____________________________________________________________________________________________________

U-Value of total assembly __________________________R-Value of insulation ___________________________Openings (windows or doors with glazing)

U-Value of assembly _____________________Low-e required, if applicable _______________

Door R-Values________________________________________________

Walls below grade (each assembly)Description of assembly ____________________________________________________________________________________________________

U-Value of total assembly __________________________R-Value of insulation ____________________________

Floors over unconditioned space (each assembly)Description of assembly ____________________________________________________________________________________________________

U-Value of total assembly __________________________R-Value of insulation ____________________________

Floors slab on grade (each assembly)Description of assembly ____________________________________________________________________________________________________

U-Value of total assembly __________________________R-Value of insulation ____________________________Horizontal/Vertical requirement ___________________Slab heated ___________

ELECTRICAL SUMMARY

ELECTRICAL SYSTEM AND EQUIPMENTTHIS SECTION REQUIRED FOR ALL PROJECTS THAT INCLUDE ELECTRICAL DESIGN

Method of Compliance:Prescriptive Performance Energy Cost Budget

Lighting ScheduleLamp type required in fixture ___________________________Number of lamps in fix ture _____________________________Ballast type used in the fixture ___________________________Number of ballasts in f ixture ____________________________Total wattage per fixture ________________________________Total interior wattage specified vs. allowed _________________Total exterior wattage specified vs. allowed _________________

Equipment schedules with motors (not used for mechanical systems)Motor horsepower ______________________________Number of phases ______________________________Minimum efficiency ____________________________Motor type ____________________________________No. of poles ___________________________________

MECHANICAL SUMMARY

MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENTTHIS SECTION REQUIRED FOR ALL PROJECTS THAT INCLUDE MECHANICAL DESIGN

Method of Compliance:Prescriptive Performance Energy Cost Budget

Thermal zoneWinter dry bulb _______________________________Summer dry bulb _______________________________

Interior design conditionsWinter dry bulb _______________________________Summer dry bulb _______________________________Relative humidity _______________________________

Building heating loadBuilding cooling loadMechanical Spacing Conditioning System

Unitary ______________________________ Description of unit ______________________________

Heating efficiency ______________________________ Cooling efficiency ______________________________

Heat output of unit ______________________________Cooling output of unit ______________________________Boiler __________________________________________Total boiler output. If oversized, state reason ___________________________Chiller __________________________________________Total chiller capacity. If oversized, state reason _________________________

List equipment efficienciesEquipment schedules with motors (mechanical systems)

Motor horsepower _______________________________Number of phases _______________________________Minimum efficiency _______________________________Motor type _____________________________________# of poles _____________________________________

Shell Variable FormRequired for all Shell, Alteration to Shell and Interior Completion Permits

Check each applicable line to match scope of work. Edit as necessary to provide clear detail of installation.Reproduce on Cover SheetMechanical____No work____Equipment set __with __without power____Trunk line installed __with __without outlets____Gas Line____ Install complete operational systemOther___________________________________________________________________________________ ___________________________________________________________________________________

Plumbing____No work____Install water service and sewer____Install building drain __and __or water distribution main __with __without branches____Install complete p lumbing systemOther________________________________________________________________________________________________________________________________________________________________________________Sprinkler____Install complete sprinkler system

Building____Install slab __partial __complete____Install demising walls____Install interior partitioning __partial __complete____Install Ceilings____White box (additional interior completion permits are required for Certificate of Occupancy and power)Other_____________________________________________________________________________________________________________________________________________________________________________________

Electrical____House panel____Service laterals to meter centers/panels located on buildings____Demise wall and ceilings only____Conduit, duct, raceway in slab____Power and lighting circuits to “J” Box____Install light fixtures____Install __Heat/Ac __ Elevator __Generator __Parking lot lighting____Install complete system

Other____________________________________________________________________________________

Please provide full information on any alternate methods and means incorporated into the design ofthis project. Provide specific details and incorporate into plan submittal any support ing documentsor agreement letters.

Special Inspections Chapter 17SPECIAL INSPECTIONS SHALL BE CONDUCTED ON ALL PROJECTS THAT FALL WITHIN BUILDING CATEGORIES AND/OR

CONTAIN ELEMENTS SUBJECT TO SPECIAL INSPECTIONS AS PRESCRIBED BY REVISED SECTION 1704.

To schedule a required pre-construction meeting with the City of Raleigh, please call Steve Luxton at(919) 516-2183 or Willis Stancil at (919) 516-2187. The main line number for the Development ServicesCustomer Service Center is (919) 516-2495.

List whom will inspect the required special inspections:

Fabricator of load bearing components

Soil tests

Concrete, caissons, piles, piers, pre-cast

Post tension concrete

Modular construction

Steel and connections, welds, bolts, anchors

Fire spray tests

Smoke control

Seismic, wind designs, Quality Assurance

Retaining walls

Masonry

Wood

Alternate Methods

EFIS

Other (describe)

Other (describe)

Owner or agent___________________________________________________________

Mixed Occupancy: No Yes Separation: NoneException: ___________________________________________________

Non-Separated M ixed Occupancy (508.3.2) Separated Mixed Occupancy (508.3.3)

Actual Area of Occupancy A + Actual Area of Occupancy B … Allowable Area of Occupancy A Allowable Area of Occupancy B

ALLOWABLE AREA AND HEIGHT CALCULATIONSTHIS SECTION FOR NEW, ADDITION, CHANGE OF USE, AND INTERIOR COMPLETIONS

EXTER IORWALL

ACTUALLENGTH

OPENLENGTH

WIDTH OFPUBLIC WAY OR

OPEN SPACE

North 124’ 0’ 0’ South 187’ 0’ 0’East 326’ 326’ 30’West 877’ 877’ 30’Total 1514’ P 1203’ F 30 W

INCREASE FRONTAGE _______54___________%SPRINKLERS _____ _________300____________%FRO M PREVIOUS PERMIT

FRONTAGE INCREASE FORMULA ALO WA BL E AREA FORMU LA

I f = 100( F – 0.25) WP 30

< 1

BOTH BUILDING AND TENANT MUST BE INDICATED ON CHART BELOW

STORYNO .

OCCU PANCY(A)

BLDG AREAPER ST ORY(ACTU AL)

(B)TABLE

5035 ARE A

(C)% OPENSP ACE

INCREASE1

(D)%

SPRINKLERINCREASE 2

(E )ALLOWABLEFL OOR ARE A

ORUNLIM ITED 3

RATIO OFACTUAL

/ALLO WABLE

(F)MAX IM UMBUILD ING

A REA4

SEPARATIONRA TING

REQ UIRED

1 M 32,760 12,500 6,750 37,500 44,250 .74 44,250 N/A1 B 2,023 23,000 0 69,000 69,000 .02 69,000 N/A

1 Open space area increases from Section 506.2 are computed thus:a. Perimeter which fronts a public way or open space having 20 feet minimum width = M=1203’/B=40’ ft (F)b. Total Building Perimeter = ___ M=1514’/B=238’__ ft (P)c. Ratio (F/P) = __. M=.97/A-2=-.16___ (F/P)d. W = Minimum width of public way = __30’___ ft (W)e. Percent of frontage increase If = 100 [ F/P - 0.25] x W/30 = ___ M=54%/B=0%__ (%)

2 The sprinkler increase per Section 506.3 is as follows:a. Multistory building Is = 200 percentb. Single story building Is = 300 percent

3 Unlimited area applicable under conditions of Sections Group B, F, M, S, A-4 (507.1, 507.2, 507.3, 507.4, 507.7); Group A motion picture (507.10); Malls (507.11); and H-2 aircraft paint hangers (507.8).

< 1

Appendix B

A 1.0

12038

Sept. 25, 2012

Permit Set

©JL

H A

rchi

tect

ure

+ D

esig

n, In

c. e

xpre

ssly

rese

rves

its

com

mon

law

cop

yrig

ht &

oth

er p

rop

erty

rig

hts

in th

ese

pla

ns. T

hese

pla

ns a

re n

ot to

be

red

uced

, cha

nged

or c

opie

d in

any

form

or m

att

er w

hats

oeve

r, no

r are

they

to b

e as

signe

d to

any

third

par

ty w

ithou

t firs

t obt

aini

ng th

e ex

pres

sed

writ

ten

perm

issio

n &

con

sent

of J

LH A

rchi

tect

ure

+ D

esig

n, In

c.

Sheet Title:

Sheet Number:

Date:

Project:

Revisions

No. / Description / Date

This sheet is formatted for a24" x 36" print. If this printdoes not measure that -

refer to the graphic scale.

john l. harveyArchitecture + Design, Inc.

2128 Old Forest DriveHillsborough, NC 27278office: (919) 883-1966cell: (919) 323-1473email:[email protected]

www.harveyarchitecture.com

Ko

Ko

Fit

clu

bN

ew U

pfit

- S

ton

ehen

ge

Mar

ket

74

28 C

ree

dm

oor

Road

Ra

leig

h,

No

rth C

aro

lina 2

7613

Click t

o buy NOW!

AcroPlot Pro

w

ww.cadzation.com Click t

o buy NOW!

AcroPlot Pro

www.cadzation.com

Page 3: KoKo Fit Club - Marlin Design Build · 2012-09-28 · Location/Key Plan Scale : N.T.S. 1 A0.1 RENOVATED TENANT SPACE - (shown cross hatched) 7412 Creedmoor Rd..- Proposed tenant space

Life Safety Plan

MAIN EXITExercise SpaceReception

Passage

Dressing

Utility

Restroom

Storage

0 1' 2' 4' 8' 12'

Graphic Scale

Scale : 1/4" = 1'-0"1

A1.1

Life Safety Plan

A 1.1

12038

Sept. 25, 2012

Permit Set

©JL

H A

rchi

tect

ure

+ D

esig

n, In

c. e

xpre

ssly

rese

rves

its

com

mon

law

cop

yrig

ht &

oth

er p

rop

erty

rig

hts

in th

ese

pla

ns. T

hese

pla

ns a

re n

ot to

be

red

uced

, cha

nged

or c

opie

d in

any

form

or m

att

er w

hats

oeve

r, no

r are

they

to b

e as

signe

d to

any

third

par

ty w

ithou

t firs

t obt

aini

ng th

e ex

pres

sed

writ

ten

perm

issio

n &

con

sent

of J

LH A

rchi

tect

ure

+ D

esig

n, In

c.

Sheet Title:

Sheet Number:

Date:

Project:

Revisions

No. / Description / Date

This sheet is formatted for a24" x 36" print. If this printdoes not measure that -

refer to the graphic scale.

john l. harveyArchitecture + Design, Inc.

2128 Old Forest DriveHillsborough, NC 27278office: (919) 883-1966cell: (919) 323-1473email:[email protected]

www.harveyarchitecture.com

Ko

Ko

Fit

clu

bN

ew U

pfit

- S

ton

ehen

ge

Mar

ket

74

28 C

ree

dm

oor

Road

Ra

leig

h,

No

rth C

aro

lina 2

7613

Click t

o buy NOW!

AcroPlot Pro

w

ww.cadzation.com Click t

o buy NOW!

AcroPlot Pro

www.cadzation.com

Page 4: KoKo Fit Club - Marlin Design Build · 2012-09-28 · Location/Key Plan Scale : N.T.S. 1 A0.1 RENOVATED TENANT SPACE - (shown cross hatched) 7412 Creedmoor Rd..- Proposed tenant space

0 1' 2' 4' 8' 12'

Graphic Scale

First Floor PlanScale : 1/4" = 1'-0"

1A2.0

First Floor 2,023 s.f. (gross - based upon field measurements)

Exercise SpaceReception

Passage

Dressing

Utility

Restroom

Storage

Interior Elevation - RestroomScale : 1/4" = 1'-0"

2A2.0

BA

First Floor Plan,Schedules &Interior Finishes

A 2.0

12038

Sept. 25, 2012

Permit Set

©JL

H A

rchi

tect

ure

+ D

esig

n, In

c. e

xpre

ssly

rese

rves

its

com

mon

law

cop

yrig

ht &

oth

er p

rop

erty

rig

hts

in th

ese

pla

ns. T

hese

pla

ns a

re n

ot to

be

red

uced

, cha

nged

or c

opie

d in

any

form

or m

att

er w

hats

oeve

r, no

r are

they

to b

e as

signe

d to

any

third

par

ty w

ithou

t firs

t obt

aini

ng th

e ex

pres

sed

writ

ten

perm

issio

n &

con

sent

of J

LH A

rchi

tect

ure

+ D

esig

n, In

c.

Sheet Title:

Sheet Number:

Date:

Project:

Revisions

No. / Description / Date

This sheet is formatted for a24" x 36" print. If this printdoes not measure that -

refer to the graphic scale.

john l. harveyArchitecture + Design, Inc.

2128 Old Forest DriveHillsborough, NC 27278office: (919) 883-1966cell: (919) 323-1473email:[email protected]

www.harveyarchitecture.com

Ko

Ko

Fit

clu

bN

ew U

pfit

- S

ton

ehen

ge

Mar

ket

74

28 C

ree

dm

oor

Road

Ra

leig

h,

No

rth C

aro

lina 2

7613

Click t

o buy NOW!

AcroPlot Pro

w

ww.cadzation.com Click t

o buy NOW!

AcroPlot Pro

www.cadzation.com

Page 5: KoKo Fit Club - Marlin Design Build · 2012-09-28 · Location/Key Plan Scale : N.T.S. 1 A0.1 RENOVATED TENANT SPACE - (shown cross hatched) 7412 Creedmoor Rd..- Proposed tenant space

0 1' 2' 4' 8' 12'

Graphic Scale

Ceiling PlanScale : 1/4" = 1'-0"

1A2.0

Ceiling Plan,Interior CaseworkDetails

A 2.1

12038

Sept. 25, 2012

Permit Set

©JL

H A

rchi

tect

ure

+ D

esig

n, In

c. e

xpre

ssly

rese

rves

its

com

mon

law

cop

yrig

ht &

oth

er p

rop

erty

rig

hts

in th

ese

pla

ns. T

hese

pla

ns a

re n

ot to

be

red

uced

, cha

nged

or c

opie

d in

any

form

or m

att

er w

hats

oeve

r, no

r are

they

to b

e as

signe

d to

any

third

par

ty w

ithou

t firs

t obt

aini

ng th

e ex

pres

sed

writ

ten

perm

issio

n &

con

sent

of J

LH A

rchi

tect

ure

+ D

esig

n, In

c.

Sheet Title:

Sheet Number:

Date:

Project:

Revisions

No. / Description / Date

This sheet is formatted for a24" x 36" print. If this printdoes not measure that -

refer to the graphic scale.

john l. harveyArchitecture + Design, Inc.

2128 Old Forest DriveHillsborough, NC 27278office: (919) 883-1966cell: (919) 323-1473email:[email protected]

www.harveyarchitecture.com

Ko

Ko

Fit

clu

bN

ew U

pfit

- S

ton

ehen

ge

Mar

ket

74

28 C

ree

dm

oor

Road

Ra

leig

h,

No

rth C

aro

lina 2

7613

Click t

o buy NOW!

AcroPlot Pro

w

ww.cadzation.com Click t

o buy NOW!

AcroPlot Pro

www.cadzation.com