Softstart Installation and maintenance instruction PS D75 ... 840 PS ...
KLIMA KLIMACOMPACTCHILLERS KALTWASSERSATZE · klima klimacompactchillers kaltwassersatze.....
Transcript of KLIMA KLIMACOMPACTCHILLERS KALTWASSERSATZE · klima klimacompactchillers kaltwassersatze.....
KLIMAKLIMA COMPACT CHILLERSKALTWASSERSATZE
..
16,000 - 60,000 BTU 4.7 - 18 KW
SOFT START STANDARD ON 1-PHASE CHILLERS SOFTSTART - FUR WECKSELSTROM CHILLER
AVAILABLE IN 50 OR 60 HZ OPTIONS PRODUKT FUR 50 HZ ODER 60 HZ..
..
..
KUHLGAS R22 ODER R407C..
REFRIGERANT GAS R22 OR R407C
RAUMSPARENDES KOMPAKT DESIGNSPACE SAVING COMPACT DESIGN
PLATTEN WARMETAUSCHERPLATE TYPE HEAT EXCHANGER
KUNDENDIENST WELTWEITWORLD WIDE SERVICE NETWORK
INNOVATION IN CHILLER SYSTEM AIRCONDITIONING A WORLD PRODUCT
Customerexpectations
Features
Soft starting
Gas free cabins, quietAirHandlers and individual zone climatecontrol. To satisfy these expectations maximum “GreenCooling Power” isprovided within the smallestpossible space.
HFLCompact Chillers provide this high level of comfort, beingdesigned for reverse cycle, i.e. for cooling & heating. Theyguarantee cabins are kept free of refrigeration gas and are veryquiet in operation. Each unit is based on a high efficiencycompressor, cupro-nickel condenser and plate type heat-exchanger. State of the art refrigeration technology ensuressuperior performance.
of HFL Compact Chillers is now standard on allsingle phase units. This eliminates the high starting currentsassociatedwith the cutting in of the Chiller compressor, therebygreatly reducing the strain imposed upon on board generatorsor shore supply. Larger units are in 3-phase power supply.
Kundenerwartungen
Design
Kühlgas freie Kabinen, leiser Lauf der Air Handlers undindividuelle Zonen – Klimatisierung in jeder Kabine. Um diesehohen Erwartungen unserer Kunden zu erfüllen, liefern wirmaximale „GreenCooling Power“ auf geringstem Raum.
HFL Compact Chillers sind für Komfort an Bord konzipiert. Siewerden für Revers – Cycle, d. h., Heizen und Kühlenausgelegt. Sie garantieren Kühlgas freie Kabinen und leisenLauf im Betrieb. Jeder Kaltwassersatz basiert auf einemH o c h l e i s t u n g s k o m p r e s s o r , K u p f e r - N i c k e l -Seewasserkondensator sowie einem Plattenwärmetauscher.Dieser aktuelle Stand in der Kühltechnologie garantierthervorragendeLeistung im Betrieb.Softstart ist für unsere Wechselstrom - Kompressoren jetztStandard. Hierdurch werden die hohen Anlaufströme derKompressoren eliminiert, so daß der plötzliche Stromschlagbeim Einschalten am Generator sowie dem Landstrom entfällt.
22Cool
Heat
Automatic
Away
Operating
Ready
Temperature C
1 2 3 4 5 6Select Up
On/Off Down
KLIMA CHILLER CONTROL PANEL DIGITAL AIRHANDLER CONTROL PANELSOFT START
Cooling and heating capacities are quoted at nominal ratings of 100 F, 38 Ccondensing temperature and 35F, 2 C evaporating temperature.ElectricalBox remotely mounted.Standard models operate at 50 Hz with an increase in output when used witha 60Hzsupply.Dedicated 60 Hzmodels are available onrequest.
Kuhl und Heizleistungen sind basierend auf einer Kondensationstemperaturvon 38 C sowie einer Verdampfungstemperatur von 2 CDer Anschlussschaltkasten ist lose.Standard Modelle basieren auf 50 Hz, einige Modelle konnen jedoch mit60 Hz betrieben werden.60 Hz Modelle als Standard erhaltlich.
Installation
Additional Heat
Quality Guarantee
The central feature of a chiller installation is the chiller itself, this is known as acondensing unit. The chiller is supplied pre-charged with refrigeration gas andfactory tested. Experienced refrigeration engineers are not an essentialrequirement for installation on board. The process of installation is similar to theinstallation of a self-contained compact air conditioner.Attention must be paid to theseawater pumps and the layout of the chilled water circulation system.The main attraction of this system is the ability to direct the generated cold energyinto thosecabins, where it ismostrequired.These cabinsarethereforerefrigerationgas free. Since no compressor is required in the accommodation areas theequipmentrunsvery quietly.
If requested, selective Air Handlers can be fitted with water valves and electricheating elements, which allow the selected cabins on board to be heated whilst therest of the remainder of the craft is air conditioned. An attractive feature to furtherenhance climate control onboard.
Each Chiller ispre-charged and factory testedCompliance regarding ABYC, U.S. Coast Guard regulations, CE marking andgeneralAirConditioningandRefrigeration Industry(ARI) standards is ensured.
Model KCC KCC KCC
Einbau
Zusatzwärme
Qualitätsgarantie
Die Zentraleinheit einer Chiller Installation ist der Kaltwassersatz. Dieser istbefüllt mit Kühlgas und wird in der Fabrik aufgefüllt und getestet. Der Einbauist daher ohne erfahrene Kühltechniker an Bord möglich. Es ergeben sich diegleichen Kriterien wie bei dem Einbau von Kompaktgeräten. Die Auslegungder Seewasserpumpen und der Chiller Umwälzpumpen ist besonderssorgfältig auszuführen. Die vom Kaltwassersatz erzeugte Kühlenergie wirdüber eine Wasserringleitung in den einzelnen Kabinen verteilt, und über diedort installierten Wärmetauscher abgenommen. Daher gelangt kein Kühlgasin die Kabinen. Da die Kompressoreinheit im Motorraum untergebracht wird,ist die Laufruhe in den Kabinen äußerst gering. Sie wird lediglich von derLuftström-Geschwindigkeit bestimmt.
Falls erforderlich können einzelne Kabinen mit zusätzlicher elektrischerWärme beheizt werden. Dies ist eine interessante Variante für den Fall, daßKranke an Bord sind. Die übrigen Kabinen können gleichzeitig gekühltwerden.
Jeder Chiller ist fabrikseitig aufgefüllt und getestet. Er entspricht denVorschriften von ABYC, U. S. Coast Guard Bestimmungen, CE Vorschriftensowie dengenerellen Standards der Klima- und Kühlindustrie (ARI)
KCC KCC KCC16KHZ 24KHZ 32KHZ 40KHZ 50KHZ 60KHZ Modell
Capacity Kuhlleistung..
Spannung
Frequenz
Phase
Laufstrom
Anlass Strom
BTU4700 7000 9400 11700 14600 17600
220 - 240 220 - 240 220 - 240 220 - 240 220 / 380 220 / 380
50 50 50 50 50 50
1 1 1 1 3 3
7.5 15 18 25
62 70.5
3 x 10 3 x 12
Soft Soft Soft Softstart start start start
16000 24000 32000 40000 50000 60000 BTUWatt Watt
Voltage V V
HZ HZ
PH PH
In A In A
Id A Id A
Frequency
Phase
Current
CurrentStarting
Dimensions Abmessungen
L W
H
L W
H
Technical Data Dimensions May Be Altered Without Notice Technische Daten
KCC KCC KCC KCC KCC KCC16KHZ 24KHZ 32KHZ 40KHZ 50KHZ 60KHZ Modell
Length 420 420 420 550 550 550310 310 310 310 310 310
31 52 61 66 72 78
5/8” 5/8” 5/8” 3/4”
5/8” 1” 1”
1” 1”
1” 1 1/4”5/8”
21 32 42
40 50
53 66 80
6016 20 26960 1200
1280 1920 2560 3200 4000 4800
3000 360024001560
320 360 360 450 470 470
L mmW mmH mmKgInch
Inch
DIA
DIA
L / min
L / min
L / hr
L / hr
LangeL mmB mmH mmKgZoll
Zoll
L / min
L / min
L / Std
L / Std
GewichtSeewasserAnschlussChillerLeitungs-AnschlussMin
Min
Seewasser
Chillwasser
Fluss
Fluss
..
..
..
BreiteHohe
..
..Width
WeightSeawater
Seawater
Chillwater
ChillerPipe -
Flow
Flow
ConnectionMinimum
Minimum
Pipe Conn.
Height
Model
O
O
TECHNOLOGYWORKING FORYOU