kitchen RoomTable of contentsProject Cover1Table of contents2Luminaire parts list3PHILIPS FBS285/218 NORMALLuminaire Data Sheet4FBS285/218 NORMALLDC (Polar)5LDC (Linear)6UGR-Table7Summary8Luminaire parts list9Photometric Results103D Rendering11Room SurfacesIsolines (E, Perpendicular)12Value Chart (E, Perpendicular)13Room 1

kitchen RoomCalculation Surface 2

kitchen Room / Luminaire parts list

2 PiecesPHILIPS FBS285/218 NORMALSee our luminaire

Article No.:catalog for an image of

Luminous flux (Luminaire): 1356 lmthe luminaire.

Luminous flux (Lamps): 2400 lm

Luminaire Wattage: 48.0 W

Luminaire classification according to CIE: 100

CIE flux code: 56 89 98 100 57

Fitting: 2 x PL L 18W (Correction Factor 1.000).

PHILIPS FBS285/218 NORMAL / Luminaire Data Sheet

kitchen Room

See our luminaire catalog for an image of the luminaire.

Luminaire classification according to CIE: 100CIE flux code: 56 89 98 100 57

Luminous emittance 1:

Luminous emittance 1:

PHILIPS FBS285/218 NORMAL / LDC (Polar)

Luminaire: PHILIPS FBS285/218 NORMAL Lamps: 2 x PL L 18W

PHILIPS FBS285/218 NORMAL / LDC (Linear)

Luminaire: PHILIPS FBS285/218 NORMAL Lamps: 2 x PL L 18W

PHILIPS FBS285/218 NORMAL / UGR-Table

Luminaire: PHILIPS FBS285/218 NORMAL Lamps: 2 x PL L 18W

The UGR values have been calculated according to CIE Publ. 117 Spacing-to-Height-Ratio = 0.25.

Height of Room: 3.000 m, Mounting Height: 3.000 m, Light loss factor:0.67

Values in Lux, Scale 1:39

Surface [%]Eav [lx]Emin [lx]Emax [lx]u0

Workplane/108301290.277

Floor30513.98860.078

Ceiling322519350.764

Walls (4)32623.63154/

Workplane:Height:

0.760 m

Grid:Boundary Zone:128 x 128 Points0.000 m

Illuminance Quotient (according to LG7): Walls / Working Plane: 0.710, Ceiling / Working Plane: 0.234.

Luminaire Parts List

No.PiecesDesignation (Correction Factor) (Luminaire) [lm] (Lamps) [lm]P [W]

12PHILIPS FBS285/218 NORMAL (1.000)1356240048.0

Total: 2712Total: 480096.0

Specific connected load: 16.00 W/m = 14.86 W/m/100 lx (Ground area: 6.00 m)

Room 1 / Luminaire parts list

2 PiecesPHILIPS FBS285/218 NORMALSee our luminaire

Article No.:catalog for an image of

Luminous flux (Luminaire): 1356 lmthe luminaire.

Luminous flux (Lamps): 2400 lm

Luminaire Wattage: 48.0 W

Luminaire classification according to CIE: 100

CIE flux code: 56 89 98 100 57

Fitting: 2 x PL L 18W (Correction Factor 1.000).

Room 1 / Photometric Results

Total Luminous Flux: 2712 lm Total Load: 96.0 W Light loss factor: 0.67Boundary Zone: 0.000 m

Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m]Workplanedirect86indirect21total108//

Calculation Surface 29022113//

Floor391251304.88

Ceiling0.002525322.57

Wall 1422163326.38

Wall 2491967326.83

Wall 3311849324.98

Wall 4491867326.81

Uniformity on the working plane u0: 0.277 (1:4)Emin / Emax: 0.232 (1:4)

Illuminance Quotient (according to LG7): Walls / Working Plane: 0.710, Ceiling / Working Plane: 0.234. Specific connected load: 16.00 W/m = 14.86 W/m/100 lx (Ground area: 6.00 m)

Room 1 / 3D Rendering

Room 1 / Calculation Surface 2 / Isolines (E, Perpendicular)

Position of surface in room: Marked point:(-0.008 m, -0.002 m, 0.760 m)

Values in Lux, Scale 1 : 22

Grid: 32 x 32 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax113 83 129 0.739 0.645

Room 1 / Calculation Surface 2 / Value Chart (E, Perpendicular)

Not all calculated values could be displayed. Position of surface in room:Marked point:(-0.008 m, -0.002 m, 0.760 m)

Values in Lux, Scale 1 : 22

Grid: 32 x 32 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax113 83 129 0.739 0.645