Kipp and Zonen Catalogo Complementos 2014

download Kipp and Zonen Catalogo Complementos 2014

of 18

Transcript of Kipp and Zonen Catalogo Complementos 2014

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    1/18

    2014

    Customer Services Price ListEective 1 April 2014Test & Calibration, Spares & Repairs

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    2/18

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    3/18

    3

    Prices

    All prices are in Euro and are ex-works Delft and ex-taxes.

    Prices are per single unit unless otherwise listed.

    Note: Orders of less than 50.00 Euro incur a charge of

    15.00 for administration costs, except where noted.

    Value Added Tax (VAT)

    Please note that for service orders within the European

    Union we are required to charge Value Added Tax (VAT)

    on the labour content, at the rate currently in force in

    The Netherlands.

    Validity

    This price list is valid for quotations and pro-forma

    invoices made by Kipp & Zonen or its representatives

    from 1 April 2014 until 31 December 2014, subject to

    changes that will be notified in advance in the form of

    an updated price list with a later issue letter.

    Shipping

    Please specify INCOTERMS for delivery and shipping

    address, where applicable, in order for us to quote for

    shipping and insurance costs. These will be itemised

    on quotations and proforma invoices.

    Special Documents

    If special documentation, such as a notarised Certificate

    of Origin, is required by the customer or for customs

    purposes the documentation fees will be itemised on

    quotations and proforma invoices.

    CE CertificationAll products in this price list have appropriate CE

    certification.

    Quality

    Kipp & Zonen B.V. is an ISO 9001:2008 certified

    company.

    Warranty

    All spare parts in this price list have a 2 year warranty

    valid from the date of invoice. Warranty on desiccant

    and repairs is 3 months from the date of invoice.

    Calibration

    All factory tests and calibrations of customer radiometers

    are carried out using the same equipment and procedures

    as for new instruments and are delivered with appropriate

    certificates. Calibration is valid for 1 year from first use,

    subject to the variations in performance due to specificoperating conditions that are given in the instrument

    specifications. Calibration is recommended every 2 years.

    For calibration please quote the part number plus the

    instrument model and serial number.

    Delivery Time

    Tests and calibrations of customer radiometers are

    scheduled in with new instrument production. The

    delivery time depends upon the individual product

    and the test or calibration required.

    Specification

    The specifications quoted in the price list are correct

    at the date of issue. Kipp & Zonen reserves the right to

    change specifications without notice due to product

    changes and improvements. For this reason there may

    sometimes be dierences between the price list and

    the published brochures.

    Conditions

    All oers made by Kipp & Zonen and all ordersacknowledged as accepted are done so in accordance

    with the General Conditions of Sale of Kipp & Zonen

    pertaining at that time (copy available upon request).

    COPYRIGHT 2014 Kipp & Zonen B.V.

    Customer Services Price ListEective from 1 April 2014Test & Calibration, Spares & Repairs

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    4/18

    4

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    5/18

    Table of contents

    Radiometer Test & CalibrationSensitivity Calibration

    Temperature Tests

    Directional Error Test

    Data Logger Calibration

    Hand-Held Calibration

    Amplifier Calibration

    Replacement Certificate

    Trackers, LoggersSOLYS 2 Sun Tracker

    2AP Sun Tracker

    SOLYS 2 & 2AP Sun Trackers

    SOLRAD

    LOGBOX SD

    Radiometer Spare Parts Radiometer Housing

    Fixing KitsSun Shields

    Levelling and Fixed Feet

    Screw-in Drying Cartridge Kits

    Clip-in Drying Cartridge Kit

    Desiccant

    Bird Stick

    Radiometer Spare Parts Domes, Windows & Ventilation UnitsReady-to-fit Glass Domes

    Ready-to-fit Quartz Domes

    Window

    Ventilation Units

    Shadow Rings

    Radiometer Spare Parts CablesMetal Plug & Yellow Cable 2-pin for CMP 3, CMP 6, CMP 11 / CUV 4, CUV 5

    Metal Plug & Yellow Cable 4-pin for CMA 6, CMA 11 / CMP 21, CMP 22 (10K) / CGR 3, CGR 4 (10K) / CNR 2 / CNF 4

    Metal Plug & Yellow Cable 8-pin for CMP 21, CMP 22 (Pt-100) / SMP3, 11 / CGR 3, CGR 4 (Pt-100) / CHP 1 / SHP1 / CNR 4

    Metal Plug & Yellow Cable 8-pin for UVS

    Metal Plug & Yellow Cable 8-pin for CSD 3

    Metal Plug & Yellow Cable 8-pin for CVF 3

    Radiometer Repairs Connectors, NR Lite / NR Lite2 CableConnector Conversions

    Replace Cable

    Radiometer Repairs Inspection, Domes, Windows, Bubble LevelsInspection

    Single Dome and Window Replacement

    Outer Dome ReplacementInner Dome Replacement

    Bubble Level Replacement

    Radiometer Repairs DetectorsDetector Replacement

    Radiometer Repairs Temperature Sensors, CNR 1, CSD, UVS, NR Lite / NR Lite2Temperature Sensor Replacement

    Smart Interface Board Replacement

    CNR 1 Repairs

    CSD Repairs

    UVS Repairs

    NR Lite Repairs

    5

    88

    8

    8

    8

    8

    8

    8

    99

    9

    9

    9

    9

    10

    1010

    10

    10

    10

    10

    10

    1111

    11

    11

    11

    11

    1212

    12

    12

    12

    12

    12

    1313

    13

    1414

    14

    1414

    14

    1515

    1616

    16

    16

    16

    16

    16

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Using this table

    Click on any item in the table of contents to be taken directly to the relevant page.

    Click on the Kipp & Zonen logo at the bottom of any page to be taken back to the table of contents.

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    6/18

    6

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    7/18

    7

    Solar Instruments

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    8/18

    When ordering please quote the calibration part number(s) plus the instrument model and serial number.

    8

    for the general conditions of sale of Kipp & Zonen B.V. please visit www.kippzonen.com

    Sensitivity Calibration0999910-1 Sensitivity calibration Pyranometers CM, CMP and SMP series 215,00

    0334710 Sensitivity calibration Pyrheliometers CH 1, CHP 1, SHP1 215,00

    0342710 Sensitivity calibration Sunshine Duration SensorsCSD 1, 2, 3 215,00

    0999910-7 Sensitivity calibration AlbedometersCMA 6, 11 360,00

    0999910-4 Matched sensitivity calibration Albedometers CM 7, 7B, 14, 14B 400,00

    0339710 Sensitivity calibration SP Lite, SP Lite2 110,00

    0348710 Sensitivity calibration PAR Lite, PQS 1 110,00

    0344710 Sensitivity calibration NR Lite , NR Lite2 300,00

    0311710 Sensitivity calibration Laboratory Thermopile CA 2 180,00

    0999910-5 Infrared source sensitivity calibration Pyrgeometers CG(R) 1, 3 215,00

    0999915 Outdoor sensitivity calibration (under clear skies for increased accuracy) Pyrgeometers CG(R) 1, 3, 4 365,00

    0999910-6 Infrared source matched sensitivity calibration Net Pyrgeometer CG 2 400,00

    0340720 Matched sensitivity calibration Net Radiometer CNR 1 540,00

    0366710 Sensitivity calibration Net Radiometer CNR 2 430,00

    0369702 Sensitivity calibration Net Radiometer CNR 4 495,00

    0337710 Sensitivity calibration Broadband UV Radiometers CUV 4, 5 265,00

    0354710 Basic sensitivity calibration UVS-E-C only 440,00

    0354711 Sensitivity calibration Single-band UVS(spectral response and air mass / ozone column correction factors) 550,00

    0354712 Sensitivity calibration Dual-band UVS(spectral response and air mass / ozone column correction factors) 660,00

    Temperature Tests0999920-1 Temperature test Pyranometers CM(P) 21, 22, 31; Pyrgeometers CG(R) 1, 2, 4 (from -20 C to +50 C in 8 steps of 10 C) 175,00

    0999920-2 Extended temperature test Pyranometers CM(P) 21, 22, 31; Pyrgeometers CG(R) 1, 2, 4 (from -40 C to +50 C in 10 steps of 10 C) 385,00

    0999920-4 Temperature test High Temperature Pyranometer CM 4 only (from -25 C to +150 C in 8 steps of 25 C) 485,00 Note: After a temperature test, a sensitivity calibration must be made

    Directional Error Test0999930 Directional error test Pyranometers CM(P) 21, 22, 31 (measured at 4 zenith angles and 4 azimuth angles) 145,00

    Data Logger Calibration0372700 Calibration and function check Data logger LOGBOX SD 150,00

    Hand-Held Calibration0365711 Calibration and function check Solar integrator SOLRAD 195,00

    0365712 Calibration and function check Irradiance meter / data logger METEON 195,00

    Amplifier Calibration0365714 Calibration Signal Amplifier AMPBOX 60,00

    Replacement Certificate0999911 Replacement Calibration Certificate (Please quote the instrument model and serial number) 25,00

    Note: Copies of the original factory calibration certificates are only available for 2 years from the date of calibration No minimum order charge

    Radiometer Test & Calibration

    Description Unit Price Part number

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    9/18

    The spare parts listed below can be fitted by the customer or by a Kipp & Zonen distributor.

    9

    for the general conditions of sale of Kipp & Zonen B.V. please visit www.kippzonen.com

    SOLYS 2 Sun Tracker0367711 Tripod Stand including 2 levelling screws 800,00

    0367715 Shading Assembly Spare Screw Kit 95,00

    All the screws and other items for putting together the SOLYS 2 sun tracker Shading Ball Assembly

    2523146 Waterproof 8-pin plug supplied loose, no cable 25,00

    For SOLYS 2 Sun Sensor cable, the cable is captive in the sensor and is not replaceable by the customer or by a Kipp & Zonen distributor

    2523148 Waterproof AC Power Connector 4-pin female plug 30,00

    2523153 Waterproof DC Power Connector 4-pin male plug 30,00

    2523131 Waterproof Ethernet Cable Cover protective cap for Ethernet cable and connector 30,00

    This also includes the Ethernet chassis socket and internal cable, which normally do not need replacing

    0016519 Levelling Screw for tripod stand, 2 per tripod 60,00

    0367719 Cable Fixing Kit items for securing radiometer cables to the sun tracker 20,00

    2523170 GPS Antenna and Cable 30,00

    Occasionally, the GPS antenna may be damaged by an accident. It is glued on and the old adhesive must be removed and the new

    antenna fitted with fresh silicon adhesive. The cable connects to the interface board inside the SOLYS 2.

    2AP Sun Tracker0353773 Motor Gearwheel Replacement Kit 195,00

    For 2 AP-GD sun trackers of Serial Number 010190 and higher. If the plastic gear wheels on the azimuth and zenith drive motors

    become worn they can be replaced by the stainless steel gears used in current production. The kit includes all the items necessary

    to replace both the gearwheels in a 2AP-GD gear drive sun tracker and full fitting instructions.

    0353770 Motor Driver Mounting Kit for 2AP-GD 495,00

    Kit includes all the items necessary to replace both the motor drivers in a 2AP-GD gear drive sun tracker and full fitting instructions

    0353771 Motor Driver Mounting Kit for 2AP-BD 495,00

    Kit includes all the items necessary to replace both the motor drivers in a 2AP-BD belt drive sun tracker and full fitting instructions0353772 Firmware Upgrade Kit for 2AP-GD 35,00

    The kit upgrades the firmware in the 2AP-GD to the latest version

    0353774 Shading Assembly Spare Screw Kit 295,00

    All the screws and other items for putting together the 2AP sun tracker Shading Ball Assembly

    SOLYS 2 & 2AP Sun Trackers0367716 Pyrheliometer Spare Screw / Clip Kit 35,00

    Screws, washers and clamp strips for fitting a CH(P) 1, SHP1 pyrheliometer to the two mounting brackets of the SOLYS2 and 2AP sun trackers

    SOLRAD2547126 Universal Mains Adapter 115/230 VAC 115,00

    3329203 RS 232 Communication Cable 9 pins, 3 m long 40,00

    LOGBOX SD3303091 Mounting Bracket Aluminium mounting bracket with stainless steel clamps for fixing LOGBOX SD to masts up to 50 mm 30,00

    Note: A mounting bracket is supplied included with all new LOGBOX SD data loggers

    Trackers, Loggers

    Description Unit Price Part number

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    10/18

    10

    for the general conditions of sale of Kipp & Zonen B.V. please visit www.kippzonen.com

    The housing spare parts listed below can be fitted by the customer or by a Kipp & Zonen distributor.

    Fixing Kits0339800 SP / PQS Fixing Kit 5,00

    3 stainless steel M5 x 25 levelling screw, 2 each stainless steel M5 x 40 mm screw and nut, 4 x flat washer for SP Lite2 / PQS 1

    0338100 Small Radiometer Fixing Kit 5,00

    2 each of stainless steel M5 x 30, 40 and 50 mm screw, nut, flat washer; for CMP 3 / SMP3 / CGR 3

    0362100 Large Radiometer Fixing Kit 2 each of stainless steel M5 x 80 mm screw, nut, flat washer, nylon insulation rings 5,00

    for CM 6B, 11, 11B, 21, 22, 31 / CG 1, 4 / CUV 3, 4, 5 / CMP 6, 11, 21, 22 / SMP11 / CGR 4

    Sun Shields9016355 Sun Shield Small snap-on fixing for CMP 3 / SMP3 / CGR 3 20,00

    9016381 Sun Shield Large snap-on fixing for CMA 6, 11 / CMP 6, 11, 21, 22 / SMP11 / CGR 4 / CUV 4, 5 25,00

    and replaces original types (no longer available)for CM 6B, 7B, 11, 11B, 14, 14B, 21, 22, 31 / CG 1, 2, 4 / CUV 3, A1, B1

    0016583 Sun Shield CNR 4 Net Radiometer 25,00

    0016584 Sun Shield CNF 4 ventilation unit 20,00

    0305722 Lower Glare Screen Kit fit to downward-facing radiometers (not for CMP 3, SMP3, CGR 3) 125,00

    for CM / CMP / SMP / CG / CGR / CUV

    Levelling and Fixed Feet0016357 Levelling Screw Small, 2 per instrument for CMP 3 / SMP3 / CGR 3 14,00

    0016358 Fixed Foot Small, 1 per instrument for CMP 3 / SMP3 / CGR 3 7,00

    0016400 Levelling Screw Large, 2 per instrument (not for CMP 3, SMP3 and CGR 3) 16,00

    for CM / CMP / SMP / CG / CGR / CUV / UVS / CV 2, CVF 3

    0016401 Fixed Foot Large, 1 per instrument (not for CMP 3, SMP3 and CGR 3) 9,00

    for CM / CMP / SMP / CG / CGR / CUV / UVS / CV 2, CVF 3

    Screw-in Drying Cartridge Kits0362702 Drying Cartridge Kit CMA 6, CMA 11 / CMP 6, CMP 11, CMP 21, CMP 22 / SMP11 / CGR 4 / CHP 1 / SHP1 / CUV 4, CUV 5 22,00

    0356111 High Temperature Drying Cartridge Kit CM 4 only 78,00

    0354110 Drying Cartridge Kit UVS-X-T 110,00

    0354111 Drying Cartridge Kit UVS-X-C only 80,00

    Note: Kits include cartridge, cover, o-ring - but not desiccant

    Clip-in Drying Cartridge Kit0305720 Drying Cartridge Kit CM 6B, 7B, 11, 11B, 14, 14B, 21, 22, 31 / CG 1, 2, 4 / CUV 3 / CH 1 / CSD 1, 2 25,00

    Note: Kit includes cartridge, cover, o-ring, clamp spring - but not desiccant

    0305165 Drying Cartridge Clamp Spring for Clip-in Drying Cartridge Kit (0305720) 10,00

    Desiccant2643960 Desiccant Refill Pack All instruments (contains 10 sachets) 10,00

    4250024 Drying Cartridge CSD 3 and CNR 4 (minimum order 5 cartridges) 4,00

    4250025 Drying Cartridge CNR 2 (minimum order 5 cartridges) 4,00

    Bird Stick0015456 Bird Stick NR Lite, NR Lite2 15,00

    Radiometer Spare Parts Radiometer housing

    Description Unit Price Part number

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    11/18

    11

    for the general conditions of sale of Kipp & Zonen B.V. please visit www.kippzonen.com

    The domes and CV 2 / CVF 3 parts listed below can be fitted by the customer or by a Kipp & Zonen distributor.

    Ready-to-fit Glass Domes

    0362417 Outer Dome Kit CMP 6, CMP 11, CMP 21 / SMP11 / CMA 6, CMA 11 / CUV 5 295,00

    Glass dome, 50 mm diameter, 2 mm thick, fitted to mounting ring

    0305168 Outer Dome Kit CM 6B, 7B, 11, 11B, 14, 14B, 21 Glass dome, 50 mm diameter, 2 mm thick, fitted to mounting ring 295,00

    Note: All dome kits include fixing screws and o-ring seal

    Note: Domes for the CUV 4 are no longer available in the original glass. These instrumentsmust be returned to the factory for fitting of a new dome and recalibration

    Ready-to-fit Quartz Domes

    0362416 Outer Dome Kit CMP 22 Quartz dome, 50 mm diameter, 4 mm thick, fitted to mounting ring 1.565,00

    0351401 Outer Dome Kit CM 22 Quartz dome, 50 mm diameter, 4 mm thick, fitted to mounting ring 1.565,00

    0305173 Outer Dome Kit CM 31 Quartz dome, 50 mm diameter, 2 mm thick, fitted to mounting ring 1.295,00

    0354100 Dome Kit UVS Series Quartz dome, 36 mm diameter, 1.5 mm thick, fitted to mounting ring 855,00

    Note: All dome kits include fixing screws and o-ring seal.

    Window

    0311720 Window Kit CA 2 Glass window and mounting ring 45,00

    0368700 Calcium Fluoride Window Kit CHP 1 / SHP1 345,00

    Tube end-cap with Calcium Fluoride (CaF)window to replace standard end-cap with Quartz window

    Spectral range 0.2 - 9.5 m (50% points)

    Note: Calcium Fluoride is soft and slightly hygroscopic and is not suitable for long-term outdoor use

    Ventilation Units

    0016609 Cover CVF4 25,00

    0015601 Cover CV 2 / CVF 3 100,00

    0016584 Sun Shield CNF 4 20,000349710 CV 2 Modification Kit for old units with push-on cover 68,00

    Updates mounting of CV 2 cover to CVF 3 method for easier removal of cover where problems are experienced due to harsh

    environmental conditions. Includes soft o-ring, grease, special mounting bolts for radiometer, special retaining screws for cover

    and instructions does not include cover

    0378700 CVF4 Fixing Kit Screws and washers for securing the CVF4 feet to a mounting plate 10,00

    2682048 Ventilation Fan CNF 4 / CVF4 Fan including tacho output 55,00

    Note: The tacho output is not connected for the CNF 4, the original non-tacho fan is no longer supplied

    2682044 Ventilation Fan CV 2 / CVF 3 Fan including tacho output 85,00

    Note: The tacho output is not connected for the CV 2, the original non-tacho fan is no longer supplied

    2682046 Spare Filter Cap Assembly CNF 4 / CVF4 Black plastic cap/grille, coarse plastic mesh filter and fine foam filter 35,00

    2682047 Spare Filters CNF 4 / CVF4 Set of 5 spare ventilation fan inlet filters 20,00

    2682916 Spare Filters CV 2 / CVF 3 Set of 5 spare ventilation fan inlet filters 20,00

    Shadow Rings

    0346700 Ventilation Unit Adapter CM 121B 395,00

    Converts CM 121B shadow ring into CM 121C, to enable fitment of a CV 2, CVF 3 or CVF4 ventilation unit

    Radiometer Spare Parts Domes, Windows & Ventilation Units

    Description Unit Price Part number

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    12/18

    12

    for the general conditions of sale of Kipp & Zonen B.V. please visit www.kippzonen.com

    The cables and connectors listed below directly replace those originally supplied with the radiometer.

    Metal Plug & Yellow Cable 2-pin for CMP 3, CMP 6, CMP 11 / CUV 4, CUV 52523144 Waterproof 2-pin plug supplied loose, no cable 15,00

    0362601 Waterproof 2-pin plug supplied pre-wired with 10 m cable 73,00

    0362603 Waterproof 2-pin plug supplied pre-wired with 25 m cable 160,00

    0362604 Waterproof 2-pin plug supplied pre-wired with 50 m cable 305,00

    0362605 Waterproof 2-pin plug supplied pre-wired with 100 m cable 595,00

    Metal Plug & Yellow Cable 4-pin for CMA 6, CMA 11 / CMP 21, CMP 22 (10K) / CGR 3, CGR 4 (10K) / CNR 2 / CNF 42523145 Waterproof 4-pin plug supplied loose, no cable 19,00

    0362611 Waterproof 4-pin plug supplied pre-wired with 10 m cable 77,00

    0362613 Waterproof 4-pin plug supplied pre-wired with 25 m cable 164,00

    0362614 Waterproof 4-pin plug supplied pre-wired with 50 m cable 309,00

    0362615 Waterproof 4-pin plug supplied pre-wired with 100 m cable 599,00

    Metal Plug & Yellow Cable 8-pin for CMP 21, CMP 22 (Pt-100) / SMP3, 11 / CGR 3, CGR 4 (Pt-100) / CHP 1 / SHP1 / CNR 4 2523146 Waterproof 8-pin plug supplied loose, no cable 25,00

    0362621 Waterproof 8-pin plug supplied pre-wired with 10 m cable 83,00

    0362623 Waterproof 8-pin plug supplied pre-wired with 25 m cable 170,00

    0362624 Waterproof 8-pin plug supplied pre-wired with 50 m cable 315,00

    0362625 Waterproof 8-pin plug supplied pre-wired with 100 m cable 605,00

    Metal Plug & Yellow Cable 8-pin for UVS2523146 Waterproof 8-pin plug supplied loose, no cable 25,00

    0362621 Waterproof 8-pin plug supplied pre-wired with 10 m cable 83,00

    0362623 Waterproof 8-pin plug supplied pre-wired with 25 m cable 170,00 Note: Cable length for UVS is limited to 25 m of this type of cable because of voltage drop on the temperature stabilisation power supply wires

    Metal Plug & Yellow Cable 8-pin for CSD 32523146 Waterproof 8-pin plug supplied loose, no cable 25,00

    0362622 Waterproof 8-pin plug supplied pre-wired with 15 m cable 112,00

    0362623 Waterproof 8-pin plug supplied pre-wired with 25 m cable 170,00

    Note: Cable length for CSD 3 is limited to 25 m of this type of cable because of voltage drop on the heater power supply wires

    Metal Plug & Yellow Cable 8-pinfor CVF 32523146 Waterproof 8-pin plug supplied loose, no cable 25,00

    0362621 Waterproof 8-pin plug supplied pre-wired with 10 m cable 83,00

    0362623 Waterproof 8-pin plug supplied pre-wired with 25 m cable 170,00

    0362624 Waterproof 8-pin plug supplied pre-wired with 50 m cable 315,00

    Note: Cable length for CVF 3 is limited to 50 m of this type of cable because of voltage drop on the heater power supply wires

    Radiometer Spare Parts Cables

    Description Unit Price Part number

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    13/18

    When ordering please quote the test, calibration, repair and spare part numbers that are required (if known) plus the instrument model and serial number.

    The repair items listed on these pages CANNOT be fitted by the customer or by a Kipp & Zonen distributor.

    After some types of repair a factory test and/or calibration must be carried out and this is shown where required. The test and/or calibration is not

    included in the repair cost. Any spare parts required during the repair are fitted at the list price without any labour charge.

    Connector ConversionsFor radiometers with captive cables fitted in glands, and for older CSD 3 and UVS, the original style of cable is no longer available. These instruments

    can be converted at the factory to use the latest style metal plugs with yellow cables. Instruments with plastic cable glands have an adaptor fitted for

    the connector socket, instruments with metal cable glands have the housing modified and the socket fitted directly to the housing.

    Note: The part numbers and prices below do not include a plug and cable. Matching plugs having the correct number of pins and with cable(s) of the desired

    length must be ordered separately. Refer to the 'Radiometer Spare Parts - Cables' page of this Price List.

    13

    for the general conditions of sale of Kipp & Zonen B.V. please visit www.kippzonen.com

    Radiometer Repairs Connectors, NR Lite / NR Lite2 Cable

    0305750 CM 6B, CM 11, CM 11B modify housing or fit adaptor. New connector socket, 2 pins. New style sun shield 215,00

    0305751 CM 7B, CM 14, CM 14B, CM 21, CM 22, CM 31 / CG 1, CG 4 255,00

    Modify housing or fit adaptor. New connector socket, 8 pins. New style sun shield

    0305752 CG 2 modify housing or fit 2 adaptors.2 new connector sockets, 8 pins. New style sun shield 375,00

    0337751 CH 1 modify housing or fit adaptor. New connector socket, 8 pins 325,00

    0337752 CUV 3 modify housing or fit adaptor. New connector socket, 2 pins. New style sun shield 215,00

    0340750 CNR 1 modify housing or fit 2 adaptors. 2 new connector sockets, 8 pins 375,00

    0342750 CSD 1, CSD 2 replace bottom plate and mounting arm with later type. New connector socket, 8 pins 290,00

    0342751 CSD 3 with orange plug replace bottom plate. New connector socket, 8 pins 260,00

    0354750 UVS with LEMO connector modify housing or fit adaptor. New connector socket, 8 pins. Modify internal wiring 340,00

    Replace Cable0344750 NR Lite, NR Lite2 replace 15 m cable 135,00

    Description Unit Price Part number

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    14/18

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    15/18

    15

    for the general conditions of sale of Kipp & Zonen B.V. please visit www.kippzonen.com

    Detector Replacement

    0305760 CM 6B replace detector assembly 270,000305761 CM 11 replace detector assembly 420,00

    0305762 CM 11B replace detector assembly 465,00

    0305763 CM 21 replace detector assembly 520,00

    0305764 CM 22 replace detector assembly, new inner quartz dome 1.040,00

    0305765 CM 31 replace detector assembly 520,00

    0362760 CMP 6 replace detector assembly 270,00

    0362761 CMP 11 / SMP11 replace detector assembly 465,00

    0362762 CMP 21 (10K) replace detector assembly 465,00

    0362763 CMP 21 (Pt-100) replace detector assembly 465,00

    0362764 CMP 22 (10K) replace detector assembly, new inner quartz dome 1.040,00

    0362765 CMP 22 (Pt-100) replace detector assembly, new inner quartz dome 1.040,00

    0305766 CG 1 replace detector assembly 280,00

    0305770 CG 2 replace one detector assembly 280,00

    0345760 CG 4 replace detector assembly 525,00

    0363760 CGR 4 (10K) replace detector assembly 525,00

    0363761 CGR 4 (Pt-100) replace detector assembly 525,00

    0334760 CH 1 replace detector assembly 705,00

    0368750 CHP 1 / SHP1 replace detector assembly 705,00

    0305767 CM 7B replace one detector assembly 270,00

    0305768 CM 14 replace one detector assembly 420,00

    0305769 CM 14B replace one detector assembly 465,00

    0362766 CMA 6 replace one detector assembly 270,00

    0362767 CMA 11 replace one detector assembly 465,00

    0342760 CSD 1, CSD 2, CSD 3 replace complete 3-detector assembly 520,00

    0364760 CUV 4, CUV 5 replace detector assembly 360,000354760-A UVS-A-C replace detector assembly 835,00

    0354760-B UVS-B-C replace detector assembly 835,00

    0354760-E UVS-E-C replace detector assembly 835,00

    0354761-A UVS-A-T / UVS-A replace detector assembly 1.030,00

    0354761-B UVS-B-T / UVS-B replace detector assembly 1.030,00

    0354761-E UVS-E-T / UVS-E replace detector assembly 1.030,00

    0354762-AB UVS-AB-T / UVS-AB replace detector assembly 1.455,00

    0354762-AE UVS-AE-T / UVS-AE replace detector assembly 1.455,00

    Note: After detector replacement, a sensitivity calibration must be made

    For CM(P) 21, 22, 31, CH 1, CG(R) 1, 2, 4 a standard or extended temperature test must also be made

    For CM(P) 21, 22, 31 a directional error test is recommended

    Radiometer Repairs Detectors

    Description Unit Price Part number

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    16/18

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    17/18

    17

  • 8/9/2019 Kipp and Zonen Catalogo Complementos 2014

    18/18

    Go to www.kippzonen.com for your local distributor or contact your local sales office

    Passion for PrecisionKipp & Zonen is the leading company in measuring solar

    radiation and atmospheric properties. Our passion for

    precision has led to the development of a large range of

    high quality instruments, from all weather radiometers to

    complete measurement systems.

    We promise our customers guaranteed performance and

    quality in: Meteorology, Climatology, Hydrology, Industry,

    Renewable Energy, Agriculture and Public Health.

    We hope you will join our passion for precision.

    HEAD OFFICE

    Kipp & Zonen B.V.

    Delftechpark 36, 2628 XH Delft

    P.O. Box 507, 2600 AM Delft

    The Netherlands

    T: +31 (0) 15 2755 210

    F: +31 (0) 15 2620 351

    [email protected]

    Kipp & Zonen Asia Pacific Pte. Ltd.

    10 Ubi Crescent Lobby E

    #02-93 Ubi Techpark

    Singapore 408564

    T: +65 (0) 6748 4700

    F: +65 (0) 6748 6098

    [email protected]

    Kipp & Zonen USA Inc.

    125 Wilbur Place

    Bohemia

    NY 11716United States of America

    T: +1 (0) 631 589 2065

    F: +1 (0) 631 589 2068

    [email protected]

    Kipp & Zonen France S.A.R.L.

    88 Avenue de lEurope77184 Emerainville

    France

    T: +33 (0) 1 64 02 50 28F: +33 (0) 1 64 02 50 29

    [email protected]

    SALES OFFICES

    Pricelist-V14