KIP Liquid Level Contents - IMI Precision Engineeringcdn.norgren.com/pdf/KIP liquid level.pdf8- 1...
Transcript of KIP Liquid Level Contents - IMI Precision Engineeringcdn.norgren.com/pdf/KIP liquid level.pdf8- 1...
8-1
KIP Liquid Level Contents
8
KIP Liquid Level
HermeticallySealed
Reed SwitchPermanent
Magnet
Float
RED
RED
Series Float Material Pressure Temperature Page
Design Considerations 8-3
Electrical Data 8-4
LS Series 1 Polypro, PBT Up to 150 psi Up to 225°F 8-5Buna N, Teflon®
LS11 Polypro, PBT 100 psi Up to 150°F 8-8
BN Series Teflon, Buna N Up to 1000 psi Up to 300°F 8-9Stainless steel
SS Sereis Stainless steel, Up to 750 psi Up to 300°F 8-12Buna
TT Series PFA 70 psi 300°F 8-15
80% Shut-off switch Stainless steel 400 psi Up to 221°F 8-16
627 Series Miniature Buna N, Polypro, PBT 400 psi Up to 300°F 8-18Multi-point Switches Stainless steel, PVC
Standard Multi-point Stainless steel, 750 psi Up to 300°F 8-20switches Buna N, PVC
8-2
KIP LIQUID LEVEL
8
www.norgren.com/fluid
Plastic Liquid Level Switches
Teflon Liquid Level Switches
Liquid Level Switches for All Your Applications
Multi Level Liquid Level Switches
8-3
KIP LIQUID LEVEL
8
High Quality Liquid Level SwitchesEngineered for Extended Service
Design Considerations• Pressure• Temperature• Mounting• Termination• Media Characteristics, such as
- Specific gravity- Corrosive characteristics- Viscosity
• Actuation Point(s)• Materials of construction• Switch life/Switch load
Norgren liquid level switches are designed to meet a completerange of application requirements. Norgren has the designengineering and application engineering expertise to help youselect the best level control for your application.
The switch contact ratings, as listed in the switch data chart, arebased on use with a resistive type load. For applications requiringthe control of an inductive or capacitance load, additionalinterface circuitry may be required. Please contact Norgren forassistance or to have a life-cycle test performed on your loadwith Norgren Leveline switches.
OperationThe hermetically sealed reed switch located inside the stem isactuated by a magnetic field created by a magnet equipped float.As the float rises and falls the magnetic field passing the switchin the stem causes the switch to either close or open.
HermeticallySealed
Reed SwitchPermanent
Magnet
Float
Norgren switches can be mounted from tank top or tank bottom orcan be adapted for side mounting. Switches will operate normallywith up to a 30° tilt from vertical .
Most single point switches operate in either a Normally Open (NO) orNormally Closed (NC) mode. Selecting the mode is as easy asremoving the retaining clip and reversing the float on the stem.Norgren switches are shipped normally open as standard. However,some are non reversible and must be ordered as NO, NC or SPDT.
Design Flexibility
Interface DetectionMany Norgren models can be modified to detect the level oftwo dissimilar liquids such as oil and water.
Mounting StylesOther mounting configurations are available such asflanges, bent stem, different NPT, straight thread andmetric size mounting plugs.
TerminationsA variety of wire terminations, custom lead lengths, cablejackets and connectors are also available.
In addition to single point detectors, Norgren also offers multipointproducts for OEM applications. Complete the Application InquirySheet on page 26 and fax to 860-677-4999 or call Norgren at 800-722-5547.
8-4
KIP LIQUID LEVEL
8
www.norgren.com/fluid
Electrical Data
Norgren Standard Reed Switches are SPST or SPDT.The Diagrams Below Show the Typical Wiring.
Form A SPST - Single Pole / Single Throw
Normally Open Dry
Normally Closed Dry
Form C SPDT - Single Pole / Double Throw
SPDT Dry Condition
Each Norgren level switch varies in rating depending on the unit, seethe chart below for electrical ratings.
RED
RED
RED
RED
BLACK
REDN.O.
N.C.COM.WHITE/RED
The reed switch is designed for reliability to millions of cycles. Toensure long life and repeatability, see the contact protectioninformation below.
Contact ProtectionIn order to take advantage of the long life, highly reliablecharacteristics of a reed switch, it is essential to provide protectionwhen switching inductive loads.
When current is interrupted, the inductance of the load generates ahigh frequency voltage, which appears across the switch contacts.If the voltage is large enough, it can cause arcing. Arcing can causethe contacts to weld to each other resulting in unreliable switchingperformance. It is essential to protect the circuit by suppressing thevoltage to prevent arcing. This can easily be accomplished throughthe use of a diode for DC circuits (Figure 1) and a resistor-capacitornetwork for AC circuits (Figure 2).
+ -
Reed Switch
Inductive Load
Figure 1D.C. Contact Protection
Figure 2A.C. Contact Protection
1N4004
+ -
Reed Switch
InductiveLoad
1
Contacts
Magnet
N
S
Hermetically Sealed Glass
Common
Magnet
N
S
Hermetically Sealed Glass
Normally Open Blade
NormallyClosed Blade
NOTE: Above ratings are for resistive loads only
Switch Ratings Max - Resistive LoadsContact Rating Volts Amps AC Amps DC
10 VA0-50 .20 .13120 .08 .05240 .04 N/A
20 VA0-50 .40 .30120 .17 .13240 .08 .06
50 VA0-50 .50 .50120 .41 .41240 .20 .20
100 VA120 .83 N/A240 .41 N/A
8-5
KIP LS 1 Series
8
LS 1 Series Level SwitchesCompact, Rugged, Yet Economical!
The LS 1 Series of liquid level switches from Norgren provide areliable, compact, low cost solution to liquid-level control for theselective OEM. This family of plastic level switches offers a broadvariety of answers to many of today’s demanding applications.Whether your problem is size, material compatibility, or wave motionsfalsely actuating switches, your answer should be found on thesepages or through a quick conversation with Norgren. A variation tothese standards will surely solve the most discriminating application.
Small, compact size with small displacementHighly reliable, yet inexpensiveSeamless cellular constructionTemperature range up to 225°FExcellent chemical resistanceNSF ApprovedUnique hex designed stem
SpecificationsMaximum Pressure @70° F
Foamed Float 150 PSI (10.3 bar)Hollow Float 10 PSI (.69 bar)
Temp. Operating RangeFoamed Float -40° to 150° F (-40° to 66° C)
LeadwirePolypro Units 22 AWG, 24" long
Recommended Minimum Liquid SP GRFoamed Polypro Float .72Hollow Polypro Float .55
PolypropyleneFoamed Float
1.00
(25)
A
1.58
(40)
1.00 (25)
9/16 Hex
1/8 NPT
9/16 Hex
7/16-20 UNF
LS 1 Series Ordering Numbers:
* UL and CSA switch ratings are 20VA pilot duty rated; 120VAC - 240VAC† “NSF Certified” - These products conform to the requirements of NSF Criteria C2 - Special
and/or Devices.- For NSF label add prefix N to the part number when ordering.
A - actuation point isapproximately midway offloat travel in liquid witha specific gravity of 1.0.
UL RecognizedFile No. E 129277
CSA ApprovedFile No. LR 90981
PolypropyleneHollow Float
Part Number MTGStem
Material Float Material
OtherWettedParts
SwitchRating
0255-024† 1/8" NPT Polypro Polypro Polypro 20VA*
0342-024 1/8" NPT Polypro Buna Polypro 20VA*
0506-024† 1/8" NPT Polypro Polypro 316 SS 10VA
0507-024† 1/8" NPT Polypro Polypro Polypro 10VA
0615-024† 7/16-20 UNF Polypro Polypro Polypro 20VA*
0689-024† 1/8" NPT Polypro Polypro Polypro 3VA SPDT
2574-024 1/8 " NPT Polypro Hollow polypro Polypro 20VA
2839-024 7/16-20 UNF Polypro Hollow polypro Polypro 20VA
8-6
KIP LS 1 Series
8
www.norgren.com/fluid
LS 1 Series with Slosh ShieldThe LS 1 Series with Slosh Shield Provides a Means of DampeningTurbulent Fluids...All Polypropylene construction ideal for beverage dispensingand ice machinesCompact size allows for minimum displacementEasily adaptable to other switch types and float combinationsfor OEM applications
SpecificationsMaximum Pressure @70° F
Foamed Float 150 PSI (10.3 bar)Hollow Float 10 PSI (.69 bar)
Temp. Operating RangeFoamed Float -40°F to 150° F (-40°C to 66° C)Hollow Float (PP) -40°F to 150° F (-40°C to 66° C)
LeadwirePolypro Units 22 AWG, 24" long
Recommended Minimum Liquid SP GRFoamed Polypro Float .72Hollow Polypro Float .55
1.00
(25)
A
1.58
(40)
.75 (19)
9/16 Hex
A
1.58
(40)
1.38 (35)
9/16 Hex
Mini LS 1 SeriesThe LS 1 Series with a Float Diameter of .75 Fits Into Those Hard toReach Places...Ultra compact size fits through small bottle or tank openingsSeamless cellular construction for a rugged float designIdeal for food and beverage applicationsUnique hex stem design minimizes potential for liming
SpecificationsMaximum Pressure 150 PSI (10.3 bar) @ 70°FTemp. Operating Range -40°F to 150°F (-40°C to 66°C)Mounting 1/8" NPT or 7/16 - 20 UNFLeads 22 AWG, 24" longRecommended Minimum
Liquid SP GR .90Float Material Seamless Cellular PolypropyleneStem and Other Parts Polypropylene
A - actuation point isapproximately midway of floattravel in liquid with a specificgravity of 1.0.
UL RecognizedFile No. E 129277
CSA ApprovedFile No. LR 90981
A - actuation point isapproximately midway offloat travel in liquid with aspecific gravity of 1.0.
UL RecognizedFile No. E 129277
CSA ApprovedFile No. LR 90981
LS 1 Series with Slosh Shield:
† “NSF Certified” - these products conform to the requirements of NSF Criteria C2 - Specialand/or Devices.
- for NSF label add prefix N to the part number when ordering.
† “NSF Certified” - these products conform to the requirements of NSF Criteria C2 - Specialand/or Devices.
- for NSF label add prefix N to the part number when ordering.
Mini LS 1 Series Ordering Numbers:Part Number MTG Material Switch Rating
0763-024† 1/8" NPT Polypro 20VA
1340-024† 7/16-20 UNF Polypro 20VA
OtherPart Stem Float Wetted Switch
Number MTG Material Material Parts Rating1347-001† 1/8" NPT Polypro Polypro Polypro 20VA1347-002† 7/16-20 UNF Polypro Polypro Polypro 20VA2841-024 1/8" NPT Polypro Hollow Polypro Polypro 20VA2842-024 7/16-20 UNF Polypro Hollow Polypro Polypro 20VA
8-7
KIP LS 1 Series
8
LS 1 Series - SidemountSidemounted Unit Ideal for Tight Spaces
Sidemount design fits small vesselsMinimal float travel and displacementHighly chemical resistant
SpecificationsMaximum Pressure Type B 70 PSI (4.8 bar)
Type P 40 PSI (2.8 bar)Temperature Range Type B -40°F to 176°F (-40° to 80°C)
Type P -40°F to 176°F (-40° to 80°C)Mounting PF 1/4Leads 22 AWG, 24" longRecommended Minimum Type B .60
Liquid SP GR Type P .80
LS 1 Series Ultra Low LevelWhen You Just Can’t Detect Low Enough - The Norgren Ultra LowLevel Switch Can Detect Liquids as Low as 5/8"
Due to the float shape and displacement, the reed switch isactivated with float riding close to the surface of the liquidVariety of stem materials to meet your specific requirementsFloat can be combined with other floats on a miniature multi-level control only (see pages 18-19) for a custom liquid levelsensor to meet your needsAvailable in different lead wire lengths, with connectors forOEM’s
SpecificationsMaximum Pressure 50 PSI (3.4 bar)Temp. Operating Range -40° to 150°F in Water (-40° to 82°C)
-40° to 225°F in Oil (-40° to 107°C)(Stainless and Brass)
Mounting 1/8" NPTLeads 22 AWG, 24" long
1.22
(31)
1.26 (32)
2.36 (60)
.87 (22)
PF 1/4
Type B
Type P
LS 1 Series Ultra Low Level:
1.00
(25)
1.58
(40)
1.88 (48)
1/8 NPT
LS 1 Sidemount Ordering Numbers
Part Number Stem Material Float Material Other Material Switch Rating
0768-024 Polypro Buna N 316 SS 20VA N.C.
0769-024 Brass Buna N 316 SS 20VA N.C.
0774-024 316 SS Buna N 316 SS 20VA N.C.
PartNumber
StemMaterial
FloatMaterial
Other WettedParts
SwitchRating
0508-024 Polyacetal Buna N 316 SS 20VA0509-024 Polypro Polypro Polypro 20VA
8-8
KIP LS 11 Series
8
www.norgren.com/fluid
1.90
(48)
.68
(17)
4.03 (102)
1.00 (25) 2.87 (73)
2.37 (60)
5/8-11 UNC
1.90
(48)
.68
(17)
4.00 (102)
2.87 (73)
2.37 (60)
1/2" NPT
All Dimensions in Inches (mm)
LS 11 Plastic SidemountDirect side mounted level controls in Polypropylene and PBTAll polypropylene construction offers broadfluid compatibilitySingle unit offers normally open or normally closed operationMounting available internally or directexternal entry
Normally Open Dry Condition:Float rises with liquid level to stop, where upon switch closes.
Normally Closed Dry Condition:Float falls with liquid level to stop, where uponswitch closes.
Actuation point is 15° +10° of float arc.
SpecificationsMaximum Pressure 100 PSI (6.9 bar) @ 70°FTemp. Operating Range -40°F to 150°F (-40° to 66°C)
Polypro-40°F to 225°F (-40° to 107°C) PBT
Leads 22 AWG, 24" longRecommended Minimum
Liquid SP GR .65
LS 11 Ordering Numbers:
† “NSF Certified” - these products conform to the requirements of NSF CriteriaC2 - Special and/or Devices.
- for NSF label add prefix N to the part number when calling
Part Number Mounting Material Switch Rating1870-024† 1/2" NPT Polypro 20VA1871-024 1/2" NPT PBT 20VA1872-024† 5/8-11 UNC Polypro 20VA1873-024 5/8-11 UNC PBT 20VA
8-9
KIP 25 BN Series
8
1.00
(25)
A
1.50
(38)
.85 (22)
1/8 NPT
1/2 Hex
1.00
(25)
A
1.50
(38)
1.00 (25)
1/8 NPT
1/2 Hex
A - actuation point isapproximately midway offloat travel in liquid witha specific gravity of 1.0.
A - actuation point is approximately midway of float travel inliquid with a specific gravity of 1.0.
UL RecognizedFile No. E 129277
CSA ApprovedFile No. LR 90981
25 BN Series—Teflon® FloatNorgren Offers Its 25 BN Series with a Spring Biased TEFLON® Floatfor High Pressure Applications
Small float design (.850 Dia.) provides flexibility for those tightspacesSolid Teflon® float design for pressures up to 1000 PSIVariety of stem float combinations to meet your technical and costrequirements
SpecificationsSwitch Rating SPST 20VAOperating Pressure 1000 PSI Maximum (68.9 bar)Operating Temperature -40° to 300°F (-40 to 149°C)Float Material Teflon®Other Wetted Materials 300 Series Stainless, EpoxyLeads 22 AWG, 24" longRecommended Minimum
Liquid SP GR .75
25 BN Series Ordering Numbers:
* UL and CSA switch ratings are 20VA pilot duty rated; 120VAC - 240VAC® Teflon is a registered trademark of E.I. Dupont De Nemours Co.
25 BN Series Ordering Numbers:
25 BN SeriesBuna N General Purpose Single Point Detector
Small, compact sizePrecise repeatabilityReliable, long-life performanceHighly resistant to shock and vibrationStem available in 316 SS or Brass
SpecificationsMaximum Pressure 150 PSI (10.3 bar)Temperature Operating Range -40° to 225°F (-40° to 107°C) in oil
to 180°F (82°C) in waterMounting 1/8" NPTLeads 22 AWG, 24" longRecommended Minimum
Liquid SP GR .50
Part Number Stem Material Switch Rating1275-024 316 SS 20VA N.O. DRY*1276-024 316 SS ?20VA N.C. DRY*
PartNumber
StemMaterial
FloatMaterial
OtherWetted Parts
SwitchRating
0105-024 316 SS Buna N 316 SS 20VA0106-024 Brass Buna N 316 SS 20VA
8-10
KIP 50 BN Series
8
www.norgren.com/fluid
1.88
(48)
A
2.70
(69)
1.88 (48)
1/4 NPT
Moisture Resistant Shrink Tubing
5/8 Hex
50 BN Moisture Resistant Liquid Level SwitchConstruction Provides Maximum Resistance to Moisture,Condensation or Water.
Ideal for use in sumps or bilgesConstruction can be adapted to other Norgren switchesDual wall polyolefin shrink tubing resists moisture
SpecificationsMaximum Pressure 150 PSI (10.3 bar)Temperature -40°F to 225°F (-40°C to 107°C) in oil
Operating Range -40°F to 180°F (-40°C to 82°C) in waterMounting 1/4" NPTLeads 18 AWG, 36" longRecommended Minimum
Liquid SP GR .55
Liquid Level Switch Ordering Numbers:
A - actuation point isapproximately midway offloat travel in liquid witha specific gravity of 1.0.
PartNumber
Stem / FloatMaterial
Other WettedMounting Material
SwitchRating
1344-001 Brass / Buna Stainless / Epoxy SPST 20VA1344-002 Brass / Buna Stainless / Epoxy SPST 100VA1344-003 304 SS / Buna Stainless / Epoxy SPST 20VA1344-004 304 SS / Buna Stainless / Epoxy SPST 100VA1344-005 304 SS / 316 SS 316 SS SPST 20VA1344-006 304 SS / 316 SS 316 SS SPST 100VA
8-11
KIP 50 BN Series
8
50 BN Series LargeLarge Size General Purpose Detector
Large float provides maximum displacement in high viscosityfluids
Can be easily extended to multiple float arrangement up to 72"long
Rugged design for heavy duty service
SpecificationsMaximum Pressure 150 PSI (10.3 bar)Temp. Operating Range -40°F to 225°F (-40°C to 107°C) in oil
-40°F to 180°F (-40°C to 82°C) in waterMounting 1/4" NPTLeads 18 AWG, 24" longRecommended Minimum
Liquid SP GR .55
50 BN Series IntermediateIntermediate Size General Purpose Detector
Highly reliable, yet inexpensiveCompact, narrow displacementStem available in 316 SS or BrassLong operating life
SpecificationsMaximum Pressure 150 PSI (10.3 bar)Temp. Operating Range -40°F to 225°F (-40°C to 107°C) in oil
-40°F to 180°F (-40°C to 82°C) inwater
Mounting 1/8" NPT - 1/4" NPTLeads 18 AWG, 24" longRecommended Minimum
Liquid SP GR .58
1.75
(45)
A
2.50
(64)
1.19 (30)
1/8 NPT
1/2 Hex
1.75
(45)
A
2.70
(69)
1.19 (30)
1/4 NPT
5/8 Hex
1.88
(48)
A
2.75
(69)
1.88 (48)
1/4 NPT
5/8 Hex
50 BN Series Inter. Ordering Numbers
A - actuation point isapproximately midway offloat travel in liquid witha specific gravity of 1.0.
A - actuation point isapproximately midway offloat travel in liquid witha specific gravity of 1.0.
50 BN Series Large Ordering Numbers:
PartNumber MTG
StemMaterial
FloatMaterial
OtherWetted Parts
SwitchRating
0108-024 1/8" 316 SS Buna N 316 SS 100VA0109-024 1/8" Brass Buna N 316 SS 100VA0500-024 1/4" 316 SS Buna N 316 SS 100VA0501-024 1/4" Brass Buna N 316 SS 100VA0502-024 1/8" 316 SS Buna N 316 SS 20VA0503-024 1/8" Brass Buna N 316 SS 20VA0504-024 1/4" 316 SS Buna N 316 SS 20VA0505-024 1/4" Brass Buna N 316 SS 20VA
PartNumber MTG
StemMaterial
FloatMaterial
OtherWetted Parts
SwitchRating
0512-024 1/4" 316 SS Buna N 316 SS 100VA0513-024 1/4" Brass Buna N 316 SS 100VA0514-024 1/4" 316 SS Buna N 316 SS 20VA0515-024 1/4" Brass Buna N 316 SS 20VA
8-12
KIP 35 SS Series
8
www.norgren.com/fluid
35 SS SeriesCompact Stainless Steel Detector for High Corrosive, HighTemperature Applications
Compact sizeLong operating lifeHighly resistant to shock and vibration
SpecificationsMaximum Pressure 275 PSI (19.0 bar)Temp. Operating Range -40° to 300°F (-40° to 149°C)Mounting 1/8" NPTLeads 22 AWG, 24" longRecommended Minimum
Liquid SP GR .80
1.06
(27)
A
1.50
(38)
1.10 (28)
1/8 NPT
1/2 Hex
2.95
(75)
2.00
(50)
1.06
(27)
1.10 (28)
1.57 (40).59 (15)
PF 1/8
.59 (15)
PF 1/8
2.95
(75)
2.31
(59)
1.00
(25)
1.00 (25)
1.57 (40)
Actuation Level in SG of 1.0
Actuation Level in SG of 1.0
A - actuation point is approximately midway of float travel inliquid with a specific gravity of 1.0.
UL RecognizedFile No. E 129277
CSA ApprovedFile No. LR 90981
* UL and CSA switch ratings are 20VA pilot duty rated; 120VAC - 240VAC† “NSF Certified” - these products conform to the requirements of NSF Criteria
C2 - Special and/or Device.- for NSF label add prefix N to the part number when ordering
35 SS Series Ordering Numbers:
35 SS Series - Sidemount“Bent Stem” Level Control for Mounting through Tank Walls
90° bend allows for side mounting where access to tank topand bottom is restrictedAvailable in all 316 SS construction
SpecificationsMaximum Pressure
SS 275 PSI (19.0 bar)Buna 150 PSI (10.3 bar)
Temp. Operating Range -40°F to 300°F (-40°C to 149°C)Buna Float -40°F to 225°F (-40°C to 107°C) in oil
-40°F to 180°F (-40°C to 82°C) in waterMounting 3/8 - 24Leads 22 AWG, 24" longRecommended Minimum?
Liquid SP GR SS .80 Buna .50
35 SS Series Sidemount Ordering Numbers:
L1 Dimension is Actuation Level in LiquidSpecific Gravity of 1.0
Stainless Steel Floats:L1=2.50 (63.5mm) ±3/16"
Buna Floats:L1=2.75 (69.9mm) ±3/16"
PartNumber
StemMaterial
FloatMaterial
OtherWetted Parts
SwitchRating
0107-024† 316 SS 316 SS 316 SS 20VA*0511-024 Brass 304 SS 316 SS 20VA*
PartNumber
StemMaterial
FloatMaterial
OtherWetted Parts
SwitchRating
2350-024 316 SS 316 SS PH 15-7 MO 20VA2351-024 316 SS Buna PH 15-7 MO 20VA2352-024 Brass 316 SS Beryllium Copper 20VA2353-024 Brass Buna Beryllium Copper 20VA
8-13
KIP 40 SS Series
8
.66
(17)
.60 (15) 3.16 (80)
3/8-24 UNF11/16 Hex
.66
(17)
1.0 (25).31 (8)
4.0 (102)
15/16 Hex1/2 NPT
40 SS Series Sidemount Ordering Numbers:
40 SS Series SidemountDirect Side Mounted Level Controls
Precise repeatabilityEase of installationInternal and external mounting available
SpecificationsMaximum Pressure 400 PSI (27.6 bar)Temp. Operating Range -40° to 300°F (-40° to 149°C)Leads 22 AWG, 24" longRecommended Minimum
Liquid SP GR .58
PartNumber Mounting
StemMaterial
OtherWetted
MaterialsSwitchRating
3736-024 3/8-24 UNF 316 SS 304 SS 20VA3735-024 1/2" NPT 316 SS 304 SS 20VA
8-14
KIP 50 SS Series
8
www.norgren.com/fluid
50 SS SeriesStainless Steel Detector for High Pressure, Corrosive and HighTemperature Applications
All stainless steel wetted surfacesHigh resistance to corrosive chemicalsOperates in high temperaturesOperates in high pressure environments
SpecificationsMaximum Pressure 750 PSI (51.7 bar)Temp. Operating Range -40°F to 300°F (-40°C to 149°C)Mounting 1/4" NPTLeads 18 AWG, 24" longRecommended Minimum?
Liquid SP GR .73
50 SS Series Low Specific GravityBuoyant Float Design for Media with Specific Gravity as Low as .40
Ideal for use as a high, low or intermediate level alarm in thestorage of propane and butaneFloat design can be adapted to Norgren multi-level configurationfor total controlTemperature range of -40°F to 300°F
SpecificationsMaximum Pressure 300 PSI (20.7 bar)Temp. Operating Range -40°F to 300°F (-40°C to 149°C)Mounting 1/2" NPTLead Wires 18 AWG, 24" longRecommended Minimum
Liquid SP GR .40
A
4.50
(114
)
1/2 NPT
7/8 Hex
3.50 (89)
A
2.70
(69)
2.00
(51)
1/4 NPT
5/8 Hex
2.15 (55)
† “NSF Certified” - these products conform to the requirements of NSFCriteria C2 - Special and/or Devices.
- for NSF label add prefix N to the part number when ordering.
Low Gravity Float Ordering Numbers:
A - actuation point isapproximately midway of floattravel in liquid with a specificgravity of 1.0.
50 SS Series Ordering Numbers:
A - actuation point isapproximately midway offloat travel in liquid witha specific gravity of 1.0.
PartNumber
Stem / FloatMaterial
Other WettedMaterials
SwitchRating
1348-001 Brass / 316 SS Stainless Steel SPST 20VA1348-002 Brass / 316 SS Stainless Steel SPST 100VA1348-003 Brass / 316 SS Stainless Steel SPDT 20VA1348-004 316 SS / 316 SS Stainless Steel SPST 20VA1348-005 316 SS / 316 SS Stainless Steel SPST 100VA1348-006 316 SS / 316 SS Stainless Steel SPDT 20VA
PartNumber
StemMaterial
FloatMaterial
OtherWetted Parts
SwitchRating
0110-024† 316 SS 316 SS 316 SS 100VA0520-024 Brass 316 SS 316 SS 100VA0521-024† 316 SS 316 SS 316 SS 20VA0522-024 Brass 316 SS 316 SS 20VA
8-15
KIP 50 TT Series
8
50 TT SeriesTeflon® Level Detector for High Purity, High Corrosive Applications
All Teflon® wetted surfacesPFA float for greater resistance to corrosivesLow particulate generationChemically inert
SpecificationsMaximum Pressure 70 PSI (4.8 bar)Temp. Operating Range -40°F to 300°F (-40°C to 149°C)Mounting 1/4" NPTLeads 22 AWG, 24" longRecommended Minimum?
Liquid SP GR .90
1.88
(48)
A
2.50
(64)
1.38 (35)
1/4 NPT
5/8 Hex
A - actuation point is approximately midway of float travel inliquid with a specific gravity of 1.0.
UL RecognizedFile No. E 129277
CSA ApprovedFile No. LR 90981
50 TT Series Ordering Numbers
* UL and CSA switch ratings are 20VA pilot duty rated; 120VAC - 240VAC® Teflon is a registered trademark of E.I. Dupont De Nemours Co.
PartNumber
StemMaterial
FloatMaterial Description
SwitchRating
0111-024 TFE PFA SPST, NO Dry 20VA*
0112-024 TFE PFA SPST, NC Dry 20VA*
0113-024 TFE PFA SPDT 3VA
8-16
KIP LIQUID LEVEL
8
www.norgren.com/fluid
80% Shut-Off Switch for Recovery RefillCylindersDesigned specifically for overfill protection of Refrigerant RecoveryTanksMeets rigid UL Requirements for Refrigerant Recovery EquipmentSwitches have been specified to meet the dimensions of therecovery tank manufacturerCustomize a switch to meet your specific needs including multiplefloats, various actuation levels and a variety of wire or connectorterminations
Pressure rating to 400 PSIG (27.6 bar)Standard for 30# and 50# D.O.T. refrigerant tanksGrooved stems keep floats from moving or falling offCan be customized for use in other size cylindersAvailable with multiple floatsUL endurance tests performed at 120/60, 240/60, 24/60, 5 VDC,12 VDC, 24 VDC
Connector Selection Data
Ground Pin
Master Keyway
Ground Pin is Longer
AMP ConnectorMates with AMP P/N 206060-1
Brad Harrison 3-pinMates with BH-P/N 70303
Brad Harrison 2-pinMates with BH-P/N 70023
8-17
KIP LIQUID LEVEL
8
80% Shut-Off Switch PartNumbering System
3.19
(81)
1.45
(37)
5.31
(135
)
.90 (23)
4 PIN ReceptacleAMP #206153-1
3 PIN ReceptacleBrad Harrison #70212
1-1/16 HEX
3/4-14 NPT
SpecificationsMaximum Pressure 400 PSIG Maximum (27.6 bar)Temperature Operating Range -40° to 221°F SS Float (-40° to 105°C)Switch Type SPST, Normally Closed DrySwitch Rating 20VAMounting Plug 3/4" NPT
Refrigerant Level Ordering Numbers:
* MAN = Manchester
** WOR = Worthington
PartNumber
“A”Dim.
“B”Dim.
TankMfgr.
TankSize
PINType
0708-0013.19(81)
5.31(135)
(MAN)*,(WOR)**
30#, 50# Brad 3-Pin
0808-0013.19(81)
5.31(135)
(MAN)*,(WOR)**
30#, 50# AMP 3-Pin
1007-0013.19(81)
5.31(135)
(MAN)*,(WOR)**
30#, 50# Brad 3-Pin
1038-0018.40(213)
10.13(257)
(MAN)*,(WOR)**
250# Brad 3-Pin
1047-0016.75(172)
8.88(226)
(MAN)*,(WOR)**
100# Brad 3-Pin
1302-0013.562(90)
5.688(144)
(AMTROL) 26# Brad 3-Pin
1303-0013.875(98)
6.00(152)
(AMTROL) 50# Brad 3-Pin
1546-0018.40(213)
10.13(257)
(MAN)*,(WOR)**
250# AMP 3-Pin
1628-0013.562(90)
5.688(144)
(AMTROL) 26# AMP 3-Pin
1629-0013.875(98)
6.00(152)
(AMTROL) 50# AMP 3-Pin
1632-0016.75(172)
8.88(226)
(MAN)*,(WOR)**
100# AMP 3-Pin
8-18
KIP 627 Series
8
www.norgren.com/fluid
Use the application inquiry sheet on page 8-22 for quotation and ordering
L1
L0
L2
L3
L4
L5 A
BC
627 Series MiniatureMulti-Point Level SwitchesApply any of our Single Point Detectors toyour Multi-Point ApplicationUp to 48" overall lengthUp to 5 control pointsUL Recognized File #E129277CSA Approved File #90981
Norgren Miniature Multi-Point Level controls provide a convenientmethod of customizing your level control with standard lead timesand costs. Our Miniature Multi-Point offers floats as small as .787diameter for those hard to reach areas with up to 5 actuation levelson a single tank entry. Extend your imagination and allow Norgren tobuild your custom level control when an off the shelf switchwon’t do.
Obtain a copy of Norgren Level Switch InquiryApplication Sheet and define the generalrequirements (see page 26):1. Mounting type.2. Stem and float material.3. Float type, noting temperature ranges, pressure limitations andminimum recommended specific gravity.
4. Switch type, considering voltage and load requirements.5. Wiring group, noting that wiring group I can be utilized with upto 5 levels and wiring group ll can be utilized with 3 levels max.
6. Number of actuation points and the distance from the bottom ofthe mounting plug- Specify L1 through L5.
7. LO-Overall length, which is L1 plus the “C” dimension of yourfloat selection.
8. Switch logic, either normally closed or normally open. Whenspecifying switch logic, please indicate switch condition whentank is dry.
9. Provide a sketch or drawing along with other pertinentinformation for proper switch selection.
A = minimum distance to highest levelB = minimum distance between levels using two floatsC = distance from lowest level to end of unit
Float Number A Dim. B Dim. C Dim.0118-001 3/4" 1-1/2" 1"0126-002 3/4" 1-1/2" 1"0630-001 3/4" 1-1/2" 1"0564-002 1" 2" 1-1/8"1093-001 3/4" 1-1/2" 1"1415-001 5/8" 1-9/32" 3/4"1416-001 3/4" 1-1/2" 1"2161-001 3/4" 1-1/2" 1"2304-001 3/4" 1-1/2" 1"
8-19
KIP 627 Series
8
Miniature Multi-Point DesignConsiderationsMounting Styles
WIRINGSPST SWITCHES
Group 1 Group 2Wire #22 AWG #22 AWG
Common Black NoneNO/NC SW Com. NO/NC
L1 Red Red RedL2 Yellow Yellow YellowL3 Blue Blue BlueL4 BrownL5 Orange
SELECTIONCHOICES
TYPE A TYPE B TYPE C TYPE D TYPE E TYPE F
UnitConfiguration
Mounting 1/8" NPT 1/4" NPT 1" NPT 3/4" NPT5/16" 3/8" -24Tubing THD
Maximum 316 SS, Brass up to 48"Length or PVC up to 24"
0630-001 0118-001 Buna N 0126-002 0564-002 1093-001 1415-001316 SS Float (closed cell) Float Polypropylene 304 SS Float Polypro Float Buna Float
FLOATCHOICES
Maximum 400 PSI 150 PSI 150 PSI 400 PSI 150 PSI 150 PSIPressure (19 bar) (10.3 bar) (10.3 bar) (27.6 bar) (10.3 bar) (10.3 bar)Operating -40°F to 300°F (Oil) -40°F to 225°F -40°F to 150°F -40°F to 300°F -40°F to 150°F (Oil) -40°F to 225°F
Temperature (-40°C to 149°C) (-40°C to 107°C) (-40°C to 66°C) (-40°C to 149°C) (-40°C to 66°C) (-40°C to 107°C)(Water) (Water)
-40°F to 180°F -40°F to 180°F(-40°C to 82°C) (-40°C to 82°C)
Rec. Min..80 .50 .72 .95 .90 .80Liquid SP GR
2161-001 2304-001 1417-001316 SS Float PVC Float Polypro Float
(Hollow)
FLOATCHOICES
Maximum 275 PSI 50 PSI 10 PSIPressure (19 bar) (3.4 bar) (.69 bar)Operating -40°F to 300°F -40°F to 150°F -40°F to 150°F
Temperature (-40°C to 149°C) (-40°C to 66°C) (-40°C to 66°C)Rec. Min.
.70 .80 .55Liquid SP GR
SpecificationsStem and 316 SS and Brass up toMounting 48" LengthMaterial PVC up to 24" Length
Switches SPST, 10VA or 50VASPDT, Optional
Float Stops Brass Units -Beryllium Copper Grip ringsSS Units - ARMCO PH 15-7 MOPVC Units - PVC316 SS Collar Optional
Leads 22 AWG, 24" long
1.06
(27)
1.10 (28)
1.00
(25)
1.00 (25)
1.00
(25)
1.00 (25)
1.50
(38)
.90 (23)1.
00(2
5).75 (19)
.79
(20)
.79 (20)
1.00
(25)
1.18 (29.8)
1.00
(25)
1.00 (25)
1.00
(25)
1.00 (25)
8-20
KIP Multi-Point
8
www.norgren.com/fluid
Standard Multi-Point Level SwitchesCustomize Norgren's larger single point detectors for yourmulti-point applicationUp to 72" overall lengthUp to 6 control pointsStandard Multi-Point Level controls provide a convenientmethod of customizing your level control with standard leadtimes and costsStandard Multi-Point offers up to 6 actuationlevels on a single tank entry
Obtain a copy of Norgren Level Switch InquiryApplication Sheet and define the generalrequirements: (see page 8-22)1. Determine mounting type.2. Select the stem and float material.3. Choose float type, noting temperature ranges, pressurelimitations, and minimum recommended specific gravity.
4. Select switch type considering voltage and load requirements.5. Specify wiring group.6. Determine the number of actuation points and the distance fromthe bottom of the mounting plug. Specify L1 through L6.
7. Specify LO-Overall length, which is L1 plus the “C” dimensionof your float selection.
8. Determine switch logic, either normally closed or normallyopen. When specifying switch logic, please indicate switchcondition when tank is dry.
9. Provide a sketch or drawing along with other pertinentinformation for proper switch selection.
L1
L0
L2
L3
L4
L6
L5
WIRINGSPST SWITCHES SPDT SWITCHES
Group 1 Group 2 Group 3 Group 4Wire #22 AWG #22 AWG #22 AWG #22 AWG
Common Black None Black NoneNO/NC SW Com. NO/NC NO NC SW Com NO NC
L1 Red Red Red Red Wh/Red Red Wh/Red Wh/Blk/RedL2 Yellow Yellow Yellow Yellow Wh/Yellow Yellow Wh/Yellow Wh/Blk/YelL3 Blue Blue Blue Blue Wh/Blue Blue Wh/Blue Wh/Blk/BlueL4 Brown Brown Brown Brown Wh/Brown Brown Wh/Brown Wh/Blk/BrnL5 Orange Orange Orange Orange Wh/Orange Orange Wh/Orange Wh/Blk/OrngL6 Gray Gray Gray Gray Wh/Gray Gray Wh/Gray Wh/Blk/Gray
8-21
KIP Multi-Point
8
Multi-Point Design Considerations
Mounting StylesSELECTIONCHOICES
TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6
UnitConfiguration
Mounting 1/2" NPT 1-1/4" NPT 2" NPT3" 150# 1/2" 1-1/2CS Flange Tubing NPT
Max. Length 72" 72" 72" 72" 72" 72"
0127-001 0114-001 0489-001 2305-001316 SS Float Buna N (closed cell) Float Buna N (closed cell) Float PVC Float
FLOATCHOICES
Maximum 750 PSI 150 PSI 150 PSI 15 PSIPressure (51.7 bar) (10.4 bar) (10.4 bar) (1.03 bar)Operating -40°F to 300°F (Oil) -40°F to 225°F (Oil) -40°F to 225°F -40°F to 150°F
Temperature (-40°C to 149°C) (-40°C to 107°C) (-40°C to 107°C) (-40°C to 66°C)(Water) -40°F to 180°F (Water) -40°F to 180°F
(-40°C to 82°C) (-40°C to 82°C)Recommended Min.
.73 .58 .55 .55Liquid SP GR
Specifications:Stem and 316 SS andMounting Material Brass up to 72" Length
Switches SPST, 10VA, 50VA or 100VASPDT, Optional
Float Stops Brass Units -Beryllium Copper Grip ringsSS Units - ARMCO PH 15-7 MO316 SS Collar Optional
Leads 22 AWG, 24" long
2.00
(51)
2.15 (55)
1.75
(44)
1.19 (30)
1.88
(48)
1.88 (48)
1.88
(48)
1.88 (48)
A = minimum distance to highest levelB = minimum distance between levels using two floatsC = distance from lowest level to end of unit
AC
B
Use the application inquiry sheet on page 8-22 for quotation and ordering
Float Number A Dim. B Dim. C Dim.0127-001 1-1/2" 3" 2"0114-001 1-1/2" 3" 2"0489-001 1-1/2" 3" 2"2305-001 1-1/2" 3" 2"
8-22
KIP Liquid Level Inquiry Sheet
8
www.norgren.com/fluid
Level Switch Inquiry Application Sheet
Name _________________________________________________ Company______________________________________________________
Address________________________________________________ City ______________________E-mail __________________________
State Zip _______ Telephone _______________________________ Fax _______________________________
Description of application __________________________________________________________________________________________________
_____________________________________________________________________________________________________________________
Immediate Quantity ____________ Prototype Y ______N ______ Estimated Yearly Quantity________________________________________________
Submit Sketch of Tank with Switch Location or Competitor Part Number ________________________________________________________________
_____________________________________________________________________________________________________________________
MEDIA INFORMATIONLiquid Media______________________________ Specific Gravity____________________________ Viscosity ______________________________
Maximum Temp.___________________________ Minimum Temp. ___________________________ Operating Temp. ________________________
Maximum Pressure _________________________ Operating Pressure _________________________ Tank Material___________________________
MINIATURE MULTI-POINT LEVEL SWITCHMounting: Top ___________________ Bottom____________________ Side ____________________
Mounting Type: Type A Type B Type C Type D Type E Type F
1/8" NPT__ 1/4" NPT__ 1" NPT__ 3/4" NPT__ 5/16" Tubing__ 3/8-24__ Other ______________
Stem Material: 316 SS_____ Brass_____ PVC_____ Other_______ Float Part Number ____________________
STANDARD MULTI-POINT LEVEL SWITCHMounting: Top ___________________ Bottom____________________ Side ____________________
Mounting Type: Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
1/2" NPT__ 1-1/4" NPT__ 2" NPT__ 3"150# FL(CS)__ 1/2" Tubing__ 1-1/2 NPT__ Other ______________
Stem Material: 316 SS_____ Brass_____ Other_______ Float Part Number _____________________________________
SUCTION TUBE LIQUID LEVEL CONTROLMounting Type: Type E______________ Type F ___________ Type G _____________ Other ________________________________________
Stem Material: PVC _______________Polypropylene _______________ Other _____________ Float Part Number _______________________
Overall Length Suction Tube: LS ________________________ LSE (Extended)__________________________________
OTHER SELECTION CRITERIAJunction Box _____________ Conduit Adapter______________
SWITCH TYPE10VA SPST ______________ 50VA SPST _____________ 100VA SPST ______________ 3VA SPDT ______________ 20VA SPDT_______________
Voltage ______________________ Load Description ________ Wiring Group I _____________ Wiring Group II ________________
DIMENSIONAL DATAActuation Level: Inches/MM Indicate N.O. or N.C. with Float in Dry Condition
L6 ___________________________ N.O. _________________________________ N.C. ______________________________
L5 ___________________________ N.O. _________________________________ N.C. ______________________________
L4 ___________________________ N.O. _________________________________ N.C. ______________________________
L3 ___________________________ N.O. _________________________________ N.C. ______________________________
L2 ___________________________ N.O. _________________________________ N.C. ______________________________
L1 ___________________________ N.O. _________________________________ N.C. ______________________________
Length Overall LO ______________
Please Refer to Catalog for Limitation on Numbers of Levels with Each Switch Type and Wiring Group
Application Comments __________________________________________________________________________________________________
____________________________________________________________________________________________________________________
Copy this page. Fill in the blanks.Fax it to Norgren at (860) 677-4999Call us at (800) 722-5547Date ____/____/____