Killeshal Civil Product Range - KPCkilleshalprecast.co.uk/.../UKROI-KPC-Civil-Product-Range1.pdf ·...
Transcript of Killeshal Civil Product Range - KPCkilleshalprecast.co.uk/.../UKROI-KPC-Civil-Product-Range1.pdf ·...
-
kilform
Specials made to order
civil product range
JUNCTION BOXES ESB CCTV Eircom
Services Lighting Risers
DUCT CHANNELS AND COVERS Gas Line Cover Slabs ESB Railways
Headwalls
ROAD GULLY AND LIDS Untrapped Gully Trapped Gully Large Trapped Gully
Gully Risers Cast Iron Free Flow Lids
MARKER POSTS, SLABS AND PLATES Round Top Marker Post Flat Top Marker Post Square Head Marker Post Electrical Marker Post
Duct Marker Post Duct Marker Blocks Hydrant and Water Plates Earth Rod Box
MISCELLANEOUS Retaining Wall Blocks Lamp Post Base
-
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
JUN
CT
ION
BO
XE
S
REFERENCE SIZE MM A x B x C HOLES 4 WAY HOLES 3 WAY HOLES 2 WAYHOLES
KNOCK OUTWEIGHT
KG
J/B 3 640 x 1110 x 800 535J/B 4 640 x 1110 x 800 646J/B 5 960 x 1270 x 895 1066J/B 9 440 x 590 x 400 90
J/B 10 440 x 590 x 400 45J/B 11 420 x 540 x 220 46J/B 12 850 x 850 x 950 826J/B 15 890 x 1450 x 950 1215J/B 18 1150 x 1150 x 850 1046J/B 21 1150 x 1450 x 850 1200J/B 24 450 x 700 x 650 328J/B 25 1000 x 1600 x 1040 1515J/B 26 1290 x 1310 x 1150 1600J/B 27 1190 x 1210 x 870 1113J/B 28 740 x 1210 x 900 758J/B 29 740 x 1210 x 900 851J/B 30 1075 x 1150 x 1050 1155J/B 31 875 x 950 x 900 795J/B 33 800 x 1400 x 895 870J/B 34 1090 x 1110 x 1000 1088J/B 35 1075 x 1150 x 1050 838
PAGE
2
JUNCTION BOXES
STANDARDS NOTICE: Killeshal Precast Services Boxes are manufactured to comply withEN1917:2004 Concrete manholes and inspection chambers unreinforced, steel fibre and reinforced.
-
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
JUN
CT
ION
BO
XE
S
PAGE
3
COLOUR CODE BURIED PLASTIC PIPING I.S. 370: 2007Electricity ducting
Public lightingStreet furniture / signal below 125 Volt
Gas pipeBuried potable water
SewerStorm and road drain smooth external wall duct
Storm and road drain corrugatedTelecom / fibre optic smooth external wall duct
Telecom / fibre optic corrugated dUd only-Maximum pipe outside diameter 175 mm
Any colourexcept
Red or Yellow
Reinforced walls. eircom approved. Easily knockout polystyrene cable entry
point/can be supplied with 12/no x 150mmdia straight through entry points (4/no or1. no side wall, 4/no on each cable end).
Easily manoeuvred with lifting eyes.
Ref: eircom J/B 3
eircom JUNCTION BOX 28 eircom JUNCTION BOX 29 740 x 1210 x 900mm 740 x 1210 x 900mm
Ref: eircom J/B 4
Other sizes availablecontact Killeshalscustomer service on
Ref: eircom J/B 28 Ref: eircom J/B 29
eircom JUNCTION BOX 3 eircom JUNCTION BOX 4 640 x 1110 x 800mm 640 x 1110 x 800mm
Junction Boxes Section***Colour may very depend on application
STANDARDS NOTICE:Killeshal Precast Services Boxes are manufactured to comply withEN1917:2004 Concrete manholes and inspection chambers unreinforced,steel fibre and reinforced.
-
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
PAGE
4
JUN
CT
ION
BO
XE
S
JUNCTION BOX 9 JUNCTION BOX 10 JUNCTION BOX 11 HEAVY DUTY VALVE CHAMBER
440 x 590 x 400mm HEAVY DUTY VALVE CHAMBER
440 x 590 x 200mm 420 x 540 x 220mm
Ref: J/B 9 Ref: J/B 10 Ref: J/B 11
JUNCTION BOX 12 JUNCTION BOX 15 JUNCTION BOX 18 JUNCTION BOX 21 MANHOLE BOX
850 x 850 x 950mm MANHOLE BOX
890 x 1490 x 950mm MANHOLE BOX
1150 x 1150 x 850mm MANHOLE BOX
1150 x 1450 x 850mm
Ref: J/B 12 Ref: J/B 15 Ref: J/B 18 Ref: J/B 21
Base Ref: J/B 23
Frame Ref: J/B 22
Frame Ref: J/B 19
Base Ref: J/B 20
Frame Ref: J/B 16
Base Ref: J/B 17
Frame Ref: J/B 13
Base Ref: J/B 14
Ref: J/B 9
Ref: J/B 10
ESB MINI PILLAR JUNCTION BOX 5 960 x 1270 x 895mm
Ref: J/B 5***
Reinforced walls. 100 mm shoulder to facilitate
increasing the depth. Drainage Sump. Easily manoeuvred. Multiple cable entry points. Integrated, reinforced base.
JUNCTION BOX 24 450 x 700 x 650mm
Ref: J/B 24***
***Colour may very depend on application see page 2
-
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
PAGE
5
JUN
CT
ION
BO
XE
S
TABLE FOR J/B 25, J/B 26, J/B 27
BLINDING AND EMBEDDING REQUIREMENTS IN ACCORDANCE WITH HD 25/95
SUBGRAGE DBR%
SUB-BASE THICKNESSMM
EDGE DISTANCE FROM BOXTO EDGE BLINDING MM
SUB-BASE MATERIAL
>5 225 225 GRANULAR MATERIAL (TYPE2)
5
-
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
JUN
CT
ION
BO
XE
S
PAGE
6
JUNCTION BOX 31 JUNCTION BOX 30 875 x 950 x 900mm 1075 x 1150 x 1050mm
Ref: J/B 501
Ref: J/B 30***
JUNCTION BOX RISER J/B 501 JUNCTION BOX RISER J/B 502 875 x 950 x 150mm
To suit: - J/B 31 - J/B 30
1090 x 1110 x 100mmTo suit: - J/B 26 - J/B 27 - J/B 34 - J/B 35
Ref: J/B 31***
JUNCTION BOX 33 800 x 1400 x 895mm
Ref: J/B 33***
Ref: J/B 34***
Ref: J/B 35***
Ref: J/B 502***Colour may very depend on application see page 2
For J/B 30 withoutbase see J/B 31
High adjusting riserto suit see J/B 501
For J/B 31 withbase see J/B 30
High adjusting riserto suit see J/B 501
JUNCTION BOX 35 1075 x 1150 x 1050mm
For J/B 35 with base see J/B 27
High adjusting riser to suit see J/B 502
JUNCTION BOX 34 1090 x 1110 x 1000mm
For J/B 34 with base see J/B 26
High adjusting riser to suit see J/B 502
For J/B 33 with base see J/B 25
High adjusting riser to suit see J/B 502
Riser if requiredfor high adjustment
Riser if requiredfor high adjustment
-
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
PAGE
7
DU
CT
CH
AN
NE
LS
AN
D C
OV
ER
S
DUCT CHANNEL 105 DUCT CHANNEL 108 370 x 490 x 610mm 215 x 285 x 915mm
Ref: D/CH 105
SPILLWAY CHANNEL 116 HEADWALLS 343 to 450 x 710 x 895 x 1000mm 1820 x 1037 x 2000mm
DUCT COVERRef: D/C 173
Ref: D/CH 108
DUCT COVERRef: D/C 126
DUCT CHANNEL 111 DUCT CHANNEL 117 350 x 765 x 1497mm 340 x 448 x 1000mm
DUCT COVERRef: D/C 209
Ref: D/CH 111
DUCT CHANNEL 114 DUCT CHANNEL 115 170 x 440 x 1000mm 170 x 280 x 1000mm
Ref: D/CH 115Ref: D/CH 114
Ref: D/C 228
GAS LINE COVER SLABS 1450 x 100mm 1450 x 150mm 1450 x 200mm
Ref: D/C 199Ref: D/C 242
Ref: D/CH 116
Ref: D/CH 117
Ref: M/127
Other sizes availablecontact Killeshalscustomer service on
DUCT COVERRef: D/C 260
DUCT COVERRef: D/C 262
-
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
PAGE
8
UNTRAPPED GULLY UNTRAPPED GULLY (800x380x445mm)
Ref: G/1Ref: G/1 + G/R 104 + C/250 (G/9)Ref: G/1 + G/R 104
TRAPPED GULLY TRAPPED GULLY (800x500x375mm)
Ref: G/2 Ref: G/2 + G/R 104Ref: G/2 + G/R 104 + C/250 (G/9)
LARGE TRAPPED GULLY LARGE TRAPPED GULLY (805x585x450mm)
Ref: G/5 G/R 103 + C/250 (G/9)Ref: G/5 + Ref: G/5 +
G/R 102 + C/400 (G/10)
RO
AD
GU
LLY
AN
D L
IDS
GULLY RISERS 970x970x85mm 750x650x100mm
To suit:- G/5
750x650x100mmTo suit:- G/5
610x610x100mmTo suit:- G/1- G/2
CAST IRON FREE FLOW LIDS 527x527x100mm
To suit:- G/5
515x395x75mmTo suit:- G/1- G/2- G/5
Ref: G/R 102 Ref: G/R 104Ref: G/R 103 Ref: D/400 (G/10) Ref: D/250 (G/9)Ref: G/R 101
-
PAGE
9
ELECTRICAL (180x50x935mm)
MARKER POSTS AND SLABS marker posts are placed at or behind location points for services such as
AV/SV, hydrant chambers, water and gas chambers, electric cable junctions andfield markers as markers for emergency services or service engineers
buried hazard warning marker slabs which shadow electricity lines andgas pipes, helping to avoid breaches and health and safety incidents
Ref: M/POST 105
For Line Drainage See Pre-Fabricated Drainage System Catalogue
PLATES HYDRANT PLATES WATER PLATES
The information contained in the brochure was up to date at the time of going to print. Photographs, drawings, sizes and reference numbers are givenas an indication only and can be changed without notice. Killeshal Precast Concrete Ltd reserves the right to modify product specification without notice.
MA
RK
ER
PO
ST
S &
PLA
TE
S
Ref: M/POST 113 Ref: M/POST 114 Ref: M/POST 115
RETAINING WALL BLOCKS LAMP POST BASE 1400 x 695 x 795mm 700 x 700 x 700mm
* 1200 x 1200 x 1200mm also available
Ref: M/112 Ref: IR/11
MIS
CE
LLA
NE
OU
S
DUCT MARKER BLOCK(300x300x225mm)
DUCT MARKER BLOCK(300x300x225mm)
DUCT MARKER BLOCK(300x300x225mm)
EARTH ROD BOX(325x325x150mm)
Ref: M/123
*Made to suit each individual requirements *Full range of plates available
ROUND TOP(300x100x1090mm)*Plates see below
FLAT TOP(270x80x1220mm)*Plates see below
SQUARE HEAD(75x100x1230mm)*Plates see below
DUCT(110x140x1600mm)
Ref: M/POST 101 Ref: M/POST 102 Ref: M/POST 111Ref: M/POST 116
-
R . I OFFICETel: +353 (0)57 9353018
Email: [email protected]: killeshal.com
UK OFFICETel: 0800 0393367
Email: [email protected]: killeshalprecast.co.uk