KEY FACTS · Multi-zone VESDA system FIRE SUPPRESSION Pre-action dry pipe zoned sprinkler system...

4
eStruxture | MTL-2 Data Center Our state-of-the-art MTL-2 Data Center is built to deliver both best in class availability and design flexibility to accommodate the high power densities of today’s most intensive workloads. The site is located just outside of the downtown core, combining the scale and space you expect from a destination production facility with the convenience of an urban location with easy access to the city. The building footprint allows for a wide variety of data center options, from individual racks to dedicated halls with associated office, storage and DR space for customers. The physical security is best in class, complete with perimeter fencing, biometric access control and extensive video monitoring. MTL-2 is connected to our MTL-1 facility via a redundant fibre loop, adding both geographic diversity and the ability to connect to over 20 carriers via a simple cross connect. EStruxtures’ MTL-3 facility located in the bourgeoning data center cluster of the South Shore provides clients various options relative to space, power and locational diversity. KEY FACTS ADDRESS 7001 Saint-Jacques Street, Montreal SITE OVERVIEW − Building: 187,500 sq. ft. (17,419 m 2 ) − Land: 490,000 sq. ft. (45,522 m 2 ) BUILDING DETAILS −8 halls and 30MW of critical IT load − Supports 30kW/cabinet power loads − Site completely secured by perimeter fencing, security monitored with controlled gates − Shared and dedicated suites available − Customer office, DR and storage spaces available POWER AND INFRASTRUCTURE − 30MW facility − Tier 3, N+1 mechanical and electrical systems for concurrent maintainability, PUE 1.3 CONNECTIVITY − Cloud and Carrier Neutral − 20+ carriers − Directly connect to all major clouds, including AWS, Azure, Google Cloud, Oracle Cloud, etc. − Connected by redundant and path-diverse fibre loop to eStruxture MTL-1 downtown location for even greater connectivity and diversity options

Transcript of KEY FACTS · Multi-zone VESDA system FIRE SUPPRESSION Pre-action dry pipe zoned sprinkler system...

Page 1: KEY FACTS · Multi-zone VESDA system FIRE SUPPRESSION Pre-action dry pipe zoned sprinkler system MTL-2 DC SPECIFICATIONS. DAVID CERVANTES Senior Vice President Data Center Solutions

eStruxture | MTL-2 Data CenterOur state-of-the-art MTL-2 Data Center is built to deliver both best in class availability and design flexibility to accommodate the high power densities of today’s most intensive workloads. The site is located just outside of the downtown core, combining the scale and space you expect from a destination production facility with the convenience of an urban location with easy access to the city. The building footprint allows for a wide variety of data center options, from individual racks to dedicated halls with associated office, storage and DR space for customers. The physical security is best in class, complete with perimeter fencing, biometric access control and extensive video monitoring. MTL-2 is connected to our MTL-1 facility via a redundant fibre loop, adding both geographic diversity and the ability to connect to over 20 carriers via a simple cross connect. EStruxtures’ MTL-3 facility located in the bourgeoning data center cluster of the South Shore provides clients various options relative to space, power and locational diversity.

KEY FACTS

ADDRESS7001 Saint-Jacques Street, Montreal

SITE OVERVIEW

−Building:187,500sq.ft.(17,419m2)−Land:490,000sq.ft.(45,522m2)

BUILDING DETAILS

−8hallsand30MWofcriticalITload−Supports30kW/cabinetpowerloads−Sitecompletelysecuredbyperimeterfencing, securitymonitoredwithcontrolledgates−Sharedanddedicatedsuitesavailable−Customeroffice,DRandstoragespacesavailable

POWER AND INFRASTRUCTURE

−30MWfacility−Tier3,N+1mechanicalandelectricalsystems forconcurrentmaintainability,PUE1.3

CONNECTIVITY

−CloudandCarrierNeutral−20+carriers−Directlyconnecttoallmajorclouds,including AWS,Azure,GoogleCloud,OracleCloud,etc.−Connectedbyredundantandpath-diversefibre looptoeStruxtureMTL-1downtownlocation forevengreaterconnectivityanddiversityoptions

Page 2: KEY FACTS · Multi-zone VESDA system FIRE SUPPRESSION Pre-action dry pipe zoned sprinkler system MTL-2 DC SPECIFICATIONS. DAVID CERVANTES Senior Vice President Data Center Solutions
Page 3: KEY FACTS · Multi-zone VESDA system FIRE SUPPRESSION Pre-action dry pipe zoned sprinkler system MTL-2 DC SPECIFICATIONS. DAVID CERVANTES Senior Vice President Data Center Solutions

BUILDING AND LAND SPECIFICATIONS

FACILITY SIZE 187,500sq.ft.

SITE SIZE 490,000sq.ft.(11.24acres)

TURN KEY CAPACITY MODEL

Upto8hallsand30MWofcriticalITload

YEAR COMMISSIONED 2019

SITE CONFIGURATION Singlestorydatacenterandaccompanyingofficespace

FLOOR LOAD Minimumof250lbspersq.ft.

CEILING CLEARANCE Varies,from27’to44’

FLOOD PLAIN 150’(50m)abovesealevel

LOADING DOCK 3truckbayswithlevelaccesstoreceivingarea.Additionalmulti-truckcoveredreceivingbaysavailableuponrequest.

RECEIVING AREA Heatedrecievingbaywithsecureequipmententry,unpackingandstagingareas.

POWER

SERVICE Utilityservicedeliveredviafour25kVfeedssupportedbymultipletransformersatasinglesubstation.

POWER PROVIDER HydroQuebec

TURNKEY HIGH DENSITY DESIGN

Upto30kWpercabavailablestandard.Higherdensitiesavailableuponrequest.

UPS Concurrentlymaintainable1MWN+1UPSArchitecture.Flexible2Nsolutionavailableuponrequest.

BACKUP GENERATORS ConcurrentlymaintainableN+1 ongenerators. 2Navailableuponrequest.

FUEL RUN-TIME Minimumof72hoursofonsitefuelstorageatfullloadwithdiversefuelingcontractorarrangements

CONNECTIVITY

MEET ME ROOM 2redundantMeet-Me-Roomsfedbydiversefacilityentrances

CONNECTIVITY Networkneutralwithaccessto20+carriersincludingAWSDirectConnect,IXReachandMegaport

IP SERVICES ManagedBandwidthwitheStruxturemanagedASnumberandIPrange

FIBER CROSS CONNECTS

Yes

COPPER CROSS CONNECTS

Yes

SECURITY

PERIMETER Entireperimetersecuredbyfencing.Twogatescontrolledbycentralsecurity.

VIDEO CCTVcoverageacrossmultiplecameras.Allfootagerecordedandstoredforminimum90days.

ON-SITE STAFFING 24/7onsitesecurityandsupport

ACCESS 24/7accessforregisteredcustomers.Cardandbiometricaccesscontrol atmantraps.Additionalcabinet,cageordatahallsecurityavailable uponrequest.

MAN TRAPS Yes

ENVIRONMENTAL CONTROLS

COOLING DISTRIBUTION

Raisedfloorcoldairsupply

COOLING CAPACITY Variesbasedondensities.Halllevelandindividualcabinetlevelcoolingsolutionsavailable.

REDUNDANCY N+1mechanicalredundancy

DESIGN Mechanicaldesignbasedonoptimalfreecooling (8+months/year)

FIRE PROTECTION

PROTECTION SYSTEM(S)

Multi-zoneVESDAsystem

FIRE SUPPRESSION Pre-actiondrypipezoned sprinklersystem

MTL-2 DC SPECIFICATIONS

Page 4: KEY FACTS · Multi-zone VESDA system FIRE SUPPRESSION Pre-action dry pipe zoned sprinkler system MTL-2 DC SPECIFICATIONS. DAVID CERVANTES Senior Vice President Data Center Solutions

DAVID CERVANTES

Senior Vice President Data Center Solutions

T 514 906 1056

[email protected]

CONTACT US

CBRE Limitée | Agence immobilière | 1250, boulevard René-Lévesque Ouest, bureau 2800 | Montréal (Québec) H3B 4W8 | T 514 849 6000 | F 514 849 7095Cet avis de non-responsabilité est applicable à CBRE Limitée, agence immobilière, et à toutes les autres divisions de la Société; incluant tous les employés et entrepreneurs indépendants (« CBRE »). Les renseignements contenus dans ce document, incluant de manière non exhaustive les projections, les images, les opinions, les hypothèses et les estimations (les « Renseignements ») n'ont pas été vérifiés par CBRE, et CBRE n'indique pas, ne justifie pas et ne garantit pas la pertinence, l’exactitude et l'exhaustivité des Renseignements. CBRE n'accepte pas et n'assume pas de responsabilité ou d’engagement, direct ou indirect, quant aux Renseignements ou aux références que le destinataire y fera. Le destinataire des Renseignements doit prendre les mesures qu'il estime nécessaires pour vérifier les Renseignements avant de les utiliser à titre de référence. Les Renseignements peuvent changer et toutes les propriétés décrites par les Renseignements peuvent être retirées du marché à tout moment, sans préavis et sans créer d’obligation de la part de CBRE vis-à-vis du destinataire. CBRE et le logo de CBRE sont les marques de service de CBRE Limitée et/ou ses affiliés ou sociétés apparentées dans d’autres pays. Toutes les autres marques représentées dans ce document appartiennent à leurs propriétaires respectifs. Tous droits réservés.

Sources : Service de cartographie canadien [email protected], DMTI Spatial, Environics Analytics, Microsoft Bing, Google Earth.

TODD BATEMAN

North American Practice Leader

Data Center Investor Services

T 312 935 1400

[email protected]

DAN CURRY

Data Center Investor Services

T 612 940 5075

[email protected]

MTL-2

MTL-1

MTL-1

MTL-2

MTL-3

eStruxture makes the Montreal market even more accessible

EnterprisesandcloudprovidersareincreasinglyturningtoMontrealforitseco-friendlyandhighlyaffordablepower,abundantfreecoolingandinternationallycompetitiveworkforce.WiththeadditionoftheMTL-2datacenter,eStruxturegivescompaniestheabilitytodesignmulti-site,carrierneutraldatacentersolutionswiththescaleandflexibilitytoaccommodateanyworkloadorpowerdensityrequirement.eStruxtureisuniquelypositionedtohelpcustomersbuildthedatacenterandnetworksolutiontheyneedbyprovidingacarrier-denseinterconnectionpointacrossmultipledatacentersitesconvenientlylocatednearthedowntownMontrealcore.