KELVIN Clim KEG Kelvin air conditioning Cooling Capacity: 100 ~ 1500 USRT Double Effect Exhaust Gas Absorption Chiller & Heater Li-Br Mo Anti Crystal ++ 1.36 COP

Transcript of KELVIN Clim KEG Clim KEG.pdf · KELVIN Clim KEG Kelvin air conditioning Cooling Capacity: 100 ~...

1 Absorption Chiller & Heater Series /

Kelvin airconditioning

KELVIN Clim KEG

Kelvin air conditioning

Cooling Capacity: 100 ~ 1500 USRT

Double Effect Exhaust Gas Absorption Chiller & Heater

Li-BrMo

AntiCrystal

++ 1.36COP

2 / Absorption Chiller & Heater Series

Kelvin airconditioningKELVIN Cilm KEG

KELVIN Clim KEG

KELVIN Clim KEG : Double Effect Exhaust Gas Absorption Chiller & HeaterCooling Capacity : 100 ~ 1500 USRT

Kelvin airconditioning

- Vertical water tube - Fin tube, 1 Pass- UA- Loss of pressure calculation- Endurable from high temp corrosion

1. Waste exhaust gas can be usedfor drive heat source.2. Convertible use of cooling and heating.3. Energy saving product.

4. Increase in the efficiency of total energy.5. No power overload in summer season.6. Environment-friendly to use water as refrigerant.

- Working at high temp soot. Endurability- Maximum flow for exhaust gas: 90kg/min

- Working at high temp soot. Endurability- Maximum flow for exhaust gas: 90kg/min

High temp. generator

Development of diverter valve Development of diverter valve

Li-BrMo

AntiCrystal

++ 1.36COP

3 Absorption Chiller & Heater Series /

Kelvin airconditioning KELVIN Clim KEG

CYCLE DIAGRAM Double Effect Exhaust Gas Absorption Chiller & Heater

Cooling Cycle Diagram

Cooling Cycle Sloution Flow

Heating Cycle Diagram

Heating Cycle Sloution Flow

Li-BrMo

AntiCrystal

++ 1.36COP

4 / Absorption Chiller & Heater Series

Kelvin airconditioning

SPECIFICATION Double Effect Exhaust Gas Absorption Chiller & Heater

Note1. 1 USRT = 3,024 kcal/h 2. Working Pressure of each water side is based on 1.0MPa (151 psig).3. Fouling factor 0.0001 m 2.h, ‘C/kcal for Absorber and Condenser, 0.0001 m 2 ·h· “C/kcal for Evaporator.4. Catalogue specifications are subject to change without prior notice.

KELVIN Cilm KEG

5 Absorption Chiller & Heater Series /

Kelvin airconditioning

SPECIFICATION Double Effect Exhaust Gas Absorption Chiller & Heater

Note1. 1 USRT = 3,024 kcal/h 2. Working Pressure of each water side is based on 1.0MPa (151 psig).3. Fouling factor 0.0001 m 2.h, ‘C/kcal for Absorber and Condenser, 0.0001 m 2 ·h· “C/kcal for Evaporator.4. Catalogue specifications are subject to change without prior notice.

KELVIN Clim KEG

6 / Absorption Chiller & Heater Series

Kelvin airconditioning

Note

KELVIN Cilm KEG

7 Absorption Chiller & Heater Series /

Kelvin airconditioning

Note

KELVIN Clim KEG

8 / Absorption Chiller & Heater Series

Kelvin airconditioning