KEK visit to Fermilab --- Week 2
description
Transcript of KEK visit to Fermilab --- Week 2
![Page 1: KEK visit to Fermilab --- Week 2](https://reader035.fdocuments.us/reader035/viewer/2022062323/56815d6e550346895dcb745e/html5/thumbnails/1.jpg)
1
KEK visit to Fermilab --- Week 2
- Made Interface Bread Board to allow KEK system to switch the clock phase. After resolving grounding issues, every thing works.
- Testing of Demod output from KEK system
From KEKClockingSystem
To (MAB), going tothe phase switches
protection: -0.6 volts min, 1.2 volts max, 1 nF to ground
![Page 2: KEK visit to Fermilab --- Week 2](https://reader035.fdocuments.us/reader035/viewer/2022062323/56815d6e550346895dcb745e/html5/thumbnails/2.jpg)
2
Testing the Demod Readout of KEK system
Magic-T50 ohm Module
eccosorb or Gunn Diode
LV biases from MMIC
Jig Board
KEK clockingsystem
(4Khz and 50 Hz)
KEK preamps(x100)
Q1KEK ADC
PS voltages
Mac Mini
![Page 3: KEK visit to Fermilab --- Week 2](https://reader035.fdocuments.us/reader035/viewer/2022062323/56815d6e550346895dcb745e/html5/thumbnails/3.jpg)
3
Start 4Khz clock End 4 Khz clock
no eccosorb
eccosorb
Hard to see changein Demodoutput
with andwithouteccosorb
Demodoutputhas smallglitches anddrifts
![Page 4: KEK visit to Fermilab --- Week 2](https://reader035.fdocuments.us/reader035/viewer/2022062323/56815d6e550346895dcb745e/html5/thumbnails/4.jpg)
4Gunn Diode ONGunn Diode
OFF
GunnDiodeswitchingON/OFFmakesclear change in DemodOutput