Keep cold and contaminated air outside Easyair T200 air curtain .pdf · 82 EASYAIR T200 Keep cold...

4
82 EASYAIR T200 Keep cold and contaminated air outside For industrial applications, Mark has the Easyair T200 in its product range. This industrial air curtain is available with 3, 4 or 5 fans, which can be combined to create the desired width. The air curtain is suitable for an installation height up to 8 metres. The EASYAIR T200 blows the warm air located at the top of the room down to the occupied area. Therefore, for this type of air curtain no heat source is required. It works simple and efficiently! Features – Economical – Sharp pricing – No maintenance required – Speed controllable – Low weight – Easy installation – Optional: vertical version – Optional: gas-fired version Optional: speed controlled low noise 1~230V EC-motor with 0-10V control. Advantages: The highest efficiency in case of speed control – Up to 50% energy saving in case of partial load – Almost completely linearly adjustable – Long lifetime – Low noise level – Integrated electronic thermal protection

Transcript of Keep cold and contaminated air outside Easyair T200 air curtain .pdf · 82 EASYAIR T200 Keep cold...

Page 1: Keep cold and contaminated air outside Easyair T200 air curtain .pdf · 82 EASYAIR T200 Keep cold and contaminated air outside For industrial applications, Mark has the Easyair T200

82

EASYAIR T200

Keep cold and contaminated air outsideFor industrial applications, Mark has the Easyair T200 in its product range. This industrial air curtain is available with 3, 4 or 5 fans, which can be combined to create the desired width. The air curtain is suitable for an installation height up to 8 metres.

The EASYAIR T200 blows the warm air located at the top of the room down to the occupied area. Therefore, for this type of air curtain no heat source is required. It works simple and efficiently!

Features– Economical– Sharp pricing– No maintenance required– Speed controllable– Low weight– Easy installation– Optional: vertical version– Optional: gas-fired version

Optional: speed controlled low noise 1~230V EC-motor with 0-10V control. Advantages:– The highest efficiency in case of speed control – Up to 50% energy saving in case of partial load– Almost completely linearly adjustable– Long lifetime– Low noise level– Integrated electronic thermal protection

Page 2: Keep cold and contaminated air outside Easyair T200 air curtain .pdf · 82 EASYAIR T200 Keep cold and contaminated air outside For industrial applications, Mark has the Easyair T200

A

260

1/2 A

35

260

330

2075

115

375

410

75115

40

210 max.min. 160

CONTROL

AUXILIAR

WARNING

ONL YOUT

460

260

260

160 min.210 max.

20 20

80

20 20

220

20

A

260

1/2 A

35

260

330

2075

115

375

410

75115

40

CONTROL

AUXILIAR

WAR

NING

ONLY

OUT

260460

260

170 70075

260

A

700

2535

50

8040

M8

75

650

390365

260A+50

A

585

700/750 675/725

750850

100

585

555

300

130

700/750 700/750

Ø9,1

A

260

1/2 A

35

260

330

2075

115

375

410

75115

40

210 max.min. 160

CONTROL

AUXILIAR

WARNING

ONL YOUT

460

260

260

160 min.210 max.

20 20

80

20 20

220

20

A

260

1/2 A

35

260

330

2075

115

375

410

75115

40

CONTROL

AUXILIAR

WAR

NING

ONLY

OUT

260460

260

170 70075

260

A

700

2535

50

8040

M8

75

650

390365

260A+50

A

585

700/750 675/725

750850

100

585

555

300

130

700/750 700/750

Ø9,1

Type Length Air displace-ment

Connection voltage

Current Weight Mounting height

mm m3/h V A kg m

T200 provided with 3 fans 2100 11200 400 2,01 93 4-6

T200 provided with 4 fans 3000 14900 400 2,68 130 4-6

T200 provided with 5 fans 3500 18650 400 3,35 153 4-6

It is possible to combine the above mentioned Easyair T200 air curtains to create the desired lenght.

Dimensions

Lenghts A (mm)210030003500

Technical information

Assembly/location suggestions

83

Page 3: Keep cold and contaminated air outside Easyair T200 air curtain .pdf · 82 EASYAIR T200 Keep cold and contaminated air outside For industrial applications, Mark has the Easyair T200

Controls

5-stepregulator

400V

or

High/low/off regulator0616170

Door contact*

(Optional)

* Not delivery by Mark.Isolator switch

Hot water-supplied air heaters - 84

Page 4: Keep cold and contaminated air outside Easyair T200 air curtain .pdf · 82 EASYAIR T200 Keep cold and contaminated air outside For industrial applications, Mark has the Easyair T200

0665

002_

W W W.MARKCLIMATE.COM

Distributed byAdremit Limited.Unit 5A Commercial Courtyard, Duke Street, Settle,North Yorkshire, United Kingdom. BD24 9RHT: +44 (0) 1729 824 108W: www.puravent.co.ukE: [email protected]