Kathrein-80010656 (6 gab)

2
7/21/2019 Kathrein-80010656 (6 gab) http://slidepdf.com/reader/full/kathrein-80010656-6-gab 1/2 34 For more information about additional mounting accessories please refer to page 189 XXPol Panel 1695–2690/1695–2690 35°(–30°)/35°(+30°) 19.5/19.5dBi 2°–10°/2°–10°T Type No. 80010656 Left side, high band Y1, connector 1–2 1695–2690 Frequency Range (MHz) 1695 1880 1850 1990 1920 2170 2300 2400 2500 2690 Gain at mid Tilt (dBi) 18.7 19.2 19.5 19.7 19.5 Gain over all Tilts (dBi) 18.6 ± 0.5 19.1 ± 0.3 19.4 ± 0.4 19.6 ± 0.5 19.4 ± 1.1 Horizontal Pattern: Azimuth Beamwidth (°) 41 ± 1.8 38 ± 1.7 37 ± 1.2 36 ± 2.0 33 ± 1.5 Front-to-Back Ratio, Total Power, ± 30° (dB) > 22 > 23 > 23 > 24 > 23 Azimuth Beam Squint (°) –0.5 ± 1.4 –0.5 ± 0.5 –1 ± 0.9 –1.5 ± 2.3 –0.5 ± 2.3 Vertical Pattern: Elevation Beamwidth (°) 7.8 ± 0.5 7.4 ± 0.2 7.1 ± 0.3 6.4 ± 0.4 5.8 ± 0.4 Electrical Downtilt continuously adjustable (°) 2 – 10 Tilt Accuracy (°) < 0.5 < 0.3 < 0.2 < 0.3 < 0.3 First Upper Side Lobe Suppression (dB) > 19 > 21 > 20 > 19 > 16 Cross Polar Isolation > 28 dB Port to Port Isolation > 28 dB Maximum Effective Power per Port 200 W (at 50 °C ambient temperature) Values based on ngmn-P-BASTA requirements. Right side, high band Y2, connector 3 –4 1695–2690 Frequency Range (MHz) 1695 1880 1850 1990 1920 2170 2300 2400 2500 2690 Gain at mid Tilt (dBi) 18.6 19.1 19.4 19.7 19.6 Gain over all Tilts (dBi) 18.5 ± 0.5 19.0 ± 0.5 19.3 ± 0.5 19.6 ± 0.6 19.5 ± 1.0 Horizontal Pattern: Azimuth Beamwidth (°) 41 ± 1.9 38 ± 2.3 37 ± 1.3 35 ± 1.0 33 ± 1.1 Front-to-Back Ratio, Total Power, ± 30° (dB) > 20 > 20 > 22 > 25 > 23 Azimuth Beam Squint (°) –2.5 ± 1.4 –2 ± 0.8 –2 ± 0.7 –2.5 ± 2.1 –1.5 ± 2.4 Vertical Pattern: Elevation Beamwidth (°) 7.8 ± 0.6 7.4 ± 0.3 7.1 ± 0.4 6.4 ± 0.4 5.8 ± 0.4 Electrical Downtilt continuously adjustable (°) 2 – 10 Tilt Accuracy (°) < 0.6 < 0.4 < 0.4 < 0.4 < 0.3 First Upper Side Lobe Suppression (dB) > 18 > 20 > 20 > 19 > 15 Cross Polar Isolation > 28 dB Port to Port Isolation > 28 dB Maximum Effective Power per Port 200 W (at 50 °C ambient temperature) Values based on ngmn-P-BASTA requirements. Dual-Beam Panel Frequency Range HPBW 1695–2690 Y2 1695–2690 Y1 35° 35°

description

antena

Transcript of Kathrein-80010656 (6 gab)

Page 1: Kathrein-80010656 (6 gab)

7/21/2019 Kathrein-80010656 (6 gab)

http://slidepdf.com/reader/full/kathrein-80010656-6-gab 1/234 For more information about additional mounting accessories please refer to page 189

XXPol Panel 1695–2690/1695–2690 35°(–30°)/35°(+30°) 19.5/19.5dBi 2°–10°/2°–10°T

Type No. 80010656

Left side, high band Y1, connector 1–21695–2690

Frequency Range (MHz) 1695 – 1880 1850 – 1990 1920 – 2170 2300 – 2400 2500 – 2690

Gain at mid Tilt (dBi) 18.7 19.2 19.5 19.7 19.5

Gain over all Tilts (dBi) 18.6 ± 0.5 19.1 ± 0.3 19.4 ± 0.4 19.6 ± 0.5 19.4 ± 1.1

Horizontal Pattern:

Azimuth Beamwidth (°) 41 ± 1.8 38 ± 1.7 37 ± 1.2 36 ± 2.0 33 ± 1.5

Front-to-Back Ratio,Total Power, ± 30° (dB)

> 22 > 23 > 23 > 24 > 23

Azimuth Beam Squint (°) –0.5 ± 1.4 –0.5 ± 0.5 –1 ± 0.9 –1.5 ± 2.3 –0.5 ± 2.3

Vertical Pattern:

Elevation Beamwidth (°) 7.8 ± 0.5 7.4 ± 0.2 7.1 ± 0.3 6.4 ± 0.4 5.8 ± 0.4

Electrical Downtiltcontinuously adjustable (°)

2 – 10

Tilt Accuracy (°) < 0.5 < 0.3 < 0.2 < 0.3 < 0.3First Upper Side LobeSuppression (dB)

> 19 > 21 > 20 > 19 > 16

Cross Polar Isolation > 28 dB

Port to Port Isolation > 28 dB

Maximum Effective Powerper Port

200 W (at 50 °C ambient temperature)

Values based on ngmn-P-BASTA requirements.

Right side, high band Y2, connector 3 –4

1695–2690

Frequency Range (MHz) 1695 – 1880 1850 – 1990 1920 – 2170 2300 – 2400 2500 – 2690

Gain at mid Tilt (dBi) 18.6 19.1 19.4 19.7 19.6

Gain over all Tilts (dBi) 18.5 ± 0.5 19.0 ± 0.5 19.3 ± 0.5 19.6 ± 0.6 19.5 ± 1.0

Horizontal Pattern:

Azimuth Beamwidth (°) 41 ± 1.9 38 ± 2.3 37 ± 1.3 35 ± 1.0 33 ± 1.1

Front-to-Back Ratio,Total Power, ± 30° (dB)

> 20 > 20 > 22 > 25 > 23

Azimuth Beam Squint (°) –2.5 ± 1.4 –2 ± 0.8 –2 ± 0.7 –2.5 ± 2.1 –1.5 ± 2.4

Vertical Pattern:

Elevation Beamwidth (°) 7.8 ± 0.6 7.4 ± 0.3 7.1 ± 0.4 6.4 ± 0.4 5.8 ± 0.4

Electrical Downtiltcontinuously adjustable (°)

2 – 10

Tilt Accuracy (°) < 0.6 < 0.4 < 0.4 < 0.4 < 0.3

First Upper Side LobeSuppression (dB)

> 18 > 20 > 20 > 19 > 15

Cross Polar Isolation > 28 dB

Port to Port Isolation > 28 dB

Maximum Effective Powerper Port

200 W (at 50 °C ambient temperature)

Values based on ngmn-P-BASTA requirements.

Dual-Beam Panel

Frequency Range

HPBW

1695–2690

Y2

1695–2690

Y1

35°35°

Page 2: Kathrein-80010656 (6 gab)

7/21/2019 Kathrein-80010656 (6 gab)

http://slidepdf.com/reader/full/kathrein-80010656-6-gab 2/235For more information about additional mounting accessories please refer to page 189

Mechanical specifcations

Input 4 x 7-16 female

Connector Position bottom

Adjustment Mechanism 2x, Position bottomcontinuously adjustable

Wind load (N)(at Rated Wind Speed:150 km/h)

Maximum 780Frontal 680Lateral 190Rearside 780

Max. Wind Velocity (km/h) 200

Height / Width / Depth (mm) 1254 / 380 / 150

Category ofMounting Hardware

M (Medium)

Weight (kg) 17 / 19.2 (clamps incl.)

Packing Size (mm) 1696 / 402 / 172

Scope of Supply Panel and 2 units of clampsfor 42–115 mm diameter

Electrical specifcations, all systems

Impedance (Ω) 50

VSWR < 1.5

Return Loss (dB) > 14Interband Isolation (dB) > 28

Passive Intermodulation (dBc) < –150 (2 x 43 dBm carrier)

Polarization (°) –45, +45

Values based on ngmn-P-BASTA requirements.

Dual-Beam Panel

80010656