Kampmann GmbH - Keane Environmental...This Vario Door air curtain brochure provides you with an...
Transcript of Kampmann GmbH - Keane Environmental...This Vario Door air curtain brochure provides you with an...
-
In over 35 years,Kampmann GmbH has grown from being a family-ledcompany to becomean internationally
renowned group of companies. Kampmann systems for heating, cooling and ventilation are today market leaders in anumber of different market sectors. Innovation and the higheststandards of quality guarantee this success into the future.
We have an “ear on the market“ and the knowledge andexpertise gained from 35 years of experience in development,production and sales. This, combined with a professionally-manned research and development department, is the basis forour continuous product development. This is what allows us toprovide our customers with the best technical product at anytime.
Traditionally, Kampmann’s skills and expertise have been in theproduction of standard products with an extraordinary range ofadapted products, as well as in the production of technicallyand visually high-quality tailor-made design solutions. Ourspecialist staff deal with the building in its entirety and developunique and efficient system solutions. Our entire range isreflected in mix of standard, non-standard and tailor-madeproducts for project-orientated solutions.
We set ourselves very high standards in production. Today anexceptionally well-trained specialist workforce manufactureshigh-quality Kampmann products in three plants for customersthroughout the world. A number of different certificates areevidence of our high standards of quality, which have becomethe standard at Kampmann. Our products are characterised bythe high guaranteed DIN EN-tested heat outputs. In terms ofquality management the requirements of TÜV certificationaccording to DIN EN ISO 9001 have been met since 1996.
For decades, Kampmann customers have valued our excellentservice. Local external engineers and technicians, in-house measuring engineers and the Kampmann customer service teamare available to customers. Kampmann good air quality is nowto be found across the globe. Our sales engineers now coverthe whole of Germany and Europe.
This Vario Door air curtain brochure provides you with an insightinto our wide product range. Take a look and make up your ownmind – do not hesitate to arrange a personal visit with us. It isour aim to meet your high quality expectations, right down tothe last detail.
Well-being is our product – Quality is our benchmark!
Hendrik Kampmann Peter KaßManaging Director Managing Director
Innovative, professional,international
Door air curtainsProduction in the Kampmann works in
LingenFriedrich-Ebert-Straße 128-130
49811 Lingen (Ems)Tel. +49 591 7108-0
Fax +49 591 7108-300
-
Vario Door air curtains - For the controlled screening of open doorways
C
ContentsArticle group 1.51 Vario Door air curtains
3
Printed on environmentally-friendly, non-chlorine bleached paper; all rights reserved; reproductions, even ofexcerpts, are only possible with the express authorisation of Kampmann. We reserve the right to makemodifications, edition 297/04/08/40 GB
Basic units, Casings Accessories
Product description/AccessoriesFor the controlled sceening of open doorways. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Basic units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Overview of types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Casings • Casing extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Steel accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ControlsFan control • Wiring • Remote radio control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Accessories: 3- and 5-stage switches • Cascade module. . . . . . . . . . . . . . . . . . . . . . . . . . . 12Accessories: Control valves • Frost protection thermostat .. . . . . . . . . . . . . . . . . . . . . . . . 13BUS-controller with the KaBUS ECO system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-15
Design informationSelection process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Suggested layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Unit selection • Combined options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Layout • Limits of use • Frost protection • Low temperature operation • Sound pressure levels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Conversion to other flow and return temperatures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Water pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Technical dataDimensions of steel metal accessories, horizontal and vertical models . . . . . . . . . . . . 22Horizontal dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-24Vertical dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-26Standing dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27-28Dimensions of model sizes 10, 15, 20, 25; version without heat exchanger, horizontal 29Heat outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-35Unit data model sizes10, 15, 20, 25; version without heat exchanger, horizontal . . . . . 36
Specifications / OrderingVario door air curtain basic units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Basic unit casings • Casing extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Brackets • Steel metal accessories for installation in suspended ceilings . . . . . . . . . . . . 39Controls accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-42Vario door air curtains for use with cold stores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Order form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Your KAMPMANN contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Prod
uct
desc
ript
ion/
Acc
esso
ries
Cont
rols
Des
ign
info
rmat
ion
Tech
nica
l dat
aSp
ecif
icat
ions
/O
rder
ing
-
4
1.51 Vario Door air curtainsProduct description
For the controlled screening of open doorways
Open doorways
are nowadays an integral part of the “shopping” leisureexperience. By removing the “obstacle of a doorway”, passers-byand potential customers are motivated to enter the retail space.The usable retail floor area is thereby extended and the invitingopen entrance area with an unimpeded view of the range ofproducts results in higher numbers of customers.
Door air curtains create a comfortable interior environmentduring the heating season by screening open doorways.Customers can enjoy entering the entrance area of the store.
The warm stream of air that can be felt creates a rapid feeling ofcomfort and cosiness, especially when the temperatures outsideare low, and has the benefit over units that blow from belowthat dust and clothing is not blown up.
Vario door air curtains – now with a new attractivecasing that is simple and easy to fit
� Filter change without using a tool � Modular construction means that several units visually look like
a single unit� Can be installed within a suspended ceiling or with a bespoke
casingVario door air curtains can also be controlled with a remote radiocontroller!Vario door air curtains for use in shops, boutiques, malls, bakeriesthat open onto the street, supermarkets, public buildings withdischarge heights of between 2.3 and 3.0 m.
Kampmann door air curtains mean that the warm air stayswhere it should: inside the building
Minimizes energy losses by screening out cold air:� Continuous filtration of inlet air, thereby reducing the ingress
of dirt from the street� Fewer draughts: work stations can be positioned closer to the
entrance area, and the sales floor area can be better used. � Works with air conditioning systems in summer when run
without the supply of warm water; reduces the entry of warmoutside air, lowers the cooling outputs and energy costs
� Utilises accumulated air at ceiling level to provide a screeningcurtain of air
� Rapid warm-up after long periods of cooling thanks to the high air volumes produced by the door air curtains
� Many uses in shops of all types, malls and public buildings� Wide range of fixing and controls accessories
Prod
uct
desc
ript
ion
/A
cces
sori
es
-
5
1.51 Vario Door air curtainsProduct description
Basic units
Basic units
Vario door air curtains basic units are available in different models to meet every possibleinstallation requirement.
Vario door air curtains have a fan group that draws the air through the dry layer filter andthe high-output heat exchanger. The inclined motor base plate separates the induction andpressure side and, on the pressure side, it has an outlet angle to accommodate the leavingair rectifier or to connect to other sheet steel components.
� Made of sheet steel with sound and heat insulation on the inside� Basic unit without casing is operational and can be encased on site without any loss of
output� Large radial fans, direct-driven by 1-stage condenser motor that can be switched
between 5 fan speeds by an integral transformer� Voltage 230 V/50 Hz� Easily removable air filter (Filter class G2 according to DIN EN 779), fixed to a grille frame;
can be cleaned by vaccuming or washing� Heat exchanger made of hollow copper pipes with aluminium fins, suitable for use with
LPHW heating medium up to a temperature of max. 90 °C, maximum permissiblecontinuous operating pressure 10 bar
� Refer to Dimensions and Technical Data for nominal connection widths
Horizontal Vertical Standing (side air curtain)
Installation within a suspendedceiling
Encased Within a casing by others
Installed within a suspendedceiling with curved air outlet (non-standard model)
Horizontal air inlet at the front,vertical discharge across thewidth of the doorway
Vertical air inlet from above,vertical discharge across thewidth of the doorway
Side air inlet, horizontaldischarge across the height ofthe doorway; can be fitted onthe left or right hand side
Basic unit models based on installation position:
Possible installation positions:Pr
oduc
t de
scri
ptio
n/A
cces
sori
es
-
6
1.51 Vario Door air curtainsProduct description
Overview of types
1) Hmax. = Max. discharge height (horizontal and vertical models), Wmax. = Max. discharge width (standing model), with average to good pressureconditions/requirements/environment, see pages 16 and 17
2) We recommend installing a door air curtain on both sides of the doorway if themaximum discharge width is exceeded.
Vario Door air curtains - Overview of types Type key
Hmax.1); Wmax.1), 2) 2,3 - 3,0
Model Air volumem3/hMax.
door widthm
Model size
horizontal 660 - 1390 1.0 10
930 - 2130 1.5 15
1210 - 2820 2.0 20
1660 - 4000 2.5 25
Horizontal basic unit 330Basic unit casing 800Casing extension 810Replacement filter for basic unit 825
vertical 600 - 1390 1.0 10
930 - 2130 1.5 15
1210 - 2820 2.0 20
1660 - 4000 2.5 25
Horizontal basic unit 331Basic unit casing 801Casing extension 811Replacement filter for basic unit 825
Model Air volumem3/hMax.
door widthm
Model size
standing(side air stream) 1210 - 2820 2,0 20
1660 - 4000 2,5 25
1860 - 4260 3,0 30
2140 - 4950 3,5 35
Horizontal basic unit 332Basic unit casing 802Replacement filter for basic unit 825
1 25 330
25
330
25
801
25
802
Article no. for DataNorm/EDV entry: 151 000 _ _ _ _ _ _ (Insert type)
Vario, modelsize 25, basicunit, horizontal
Prod
uct
desc
ript
ion/
Acc
esso
ries
-
7
1.51 Vario Door air curtainsProduct description
Casings • Casing extensions
Casings · Casing extensions� Attractive slimline housing design� Simple to fit� Stable steel metal construction� Welded and smoothed corners, with side, recessed end sections that can easily be
removed for service and maintenance� Powdercoated traffic white RAL 9016 � Inlet air grille, rounded linear shape, made of a droplet profile that enhances the air flow,
powdercoated RAL 9006, easy to remove for filter inspection� Leaving air rectfier in the outlet air stream for minimum turbulence and even outlet air
flow, powdercoated RAL 9006� Unit lengths of > 2.5 m (horizontal and vertical models) are possible with casing
extensions (modular construction)
Vario door air curtain,horizontal model
1
2
34
7
5
8
6
Single-section basic unit casing for models 10 and 15 Split basic unit casing for models 20 and 25
Door air curtain basic unit (Model20) with basic unit casing
Modular construction with casing extensions
Casing extension Fitted door air curtain with casing extension
1 Door air curtain basic unit withcasing
2 Door air curtain basic unit3 Lower casing panel
of casing extension4Casing extension inlet air grille
5Casing extension connectingangle section
6Spacing bar for basic units7Side panel of basic unit casing8Leaving air rectifier
Prod
uct
desc
ript
ion/
Acc
esso
ries
-
Wall brackets · Ceiling brackets� For installing horizontal and vertical units
� Adjustable towards and from the door� Brackets powdercoated traffic white RAL 9016 � Exact height adjustment by shortening the threaded rods
Telescopic fixing with wall and ceiling brackets
1Fixing angle with wall brackets2U-rail3Insertion rail4End cover5Threaded rod
Overview of brackets/Dimensions
Model horizontal vertical standing
Supplied as standard with longitudinal openings for fixing withscrews and rawlplugs to the wall or asubstructure on site
Vario Wall brackets Wall bracketsdoor air curtain Type 100890 Type 100891
Vario Ceiling brackets Ceiling bracketsdoor air curtain Type 100895 Type 100896
2
3
1
45
Wall brackets
Ceiling brackets
Article no. for DataNorm/EDV entry: 151 000 _ _ _ _ _ _ _ (Insert type)
Wall brackets
Ceiling brackets
1.51 Vario Door air curtainsAccessories
Brackets
8
Prod
uct
desc
ript
ion
/ A
cces
sori
es
-
1Air duct for air outlet2Flexible connection
for air outlet3Leaving air rectifier4Inlet air angle 90°5Air duct for air inlet6Flexible connection for air inlet7Inlet air grilleFor dimensions refer to page 22
Sheet steel components
Article no. for DataNorm/EDV entry: 151 000 _ _ _ _ _ _ _ (Insert type)
1.51 Vario Door air curtainsAccessories
Sheet steel components
9
1Air duct for air outletwith a frame on both sides; please state length when ordering
2Flexible connection for air outletwith a frame on both sides and flexible connection made ofsailcloth for sound attenuation and to even out the length whenthere are dimensional inequalities on site; installed length: 120-160 mm
3Leaving air rectifierAir rectifier for low-turbulence air flow, comprising an adjustableair flow-enhancing louvre set; reduced induction of outlet airwith the discharged flat air stream inclined to produce lowerdivergence, whilst improving penetration depth; produces amarked reduction of the air exchange; completely powder-coated in traffic white RAL 9016; complete with steel metalframe; air rectifier sits within the frame
4Inlet air angle 90°with connecting frame on both sides; short angle section for useas a transitional section between horizontal and verticalductwork when door air curtains are installed within suspendedceilings;
5Air duct for air inletwith a frame on both sides; please state length when ordering.
6Flexible connection for air inletwith a frame on both sides and a flexible connection made ofsailcloth for sound attenuation and to even out the length whenthere are dimensional inequalities: length: 120-160 mm
7Inlet air grillewith a frame and filter fixing; the inlet grille, a linear grille madeof airflow-enhancing aluminium droplet profiles, can be easilyremoved to remove the filter. The sheet steel frame and thegrille are fully powdercoated in traffic white RAL 9016.
Replacement filter mat for inlet air grillereusable dry layer filter G2 for fitting in the inlet air grille; 1 set = 5 mats
Cross-section through leaving air rectifier
When installing door air curtains within suspendedceilings, a leaving air rectifierwith a frame is used.
Vario door air curtain basic unit (horizontal model)
1
2
3
4
5
6
7
Prod
uct
desc
ript
ion/
Acc
esso
ries
Overview of sheet steel components
Model size 10 15 20 25
1Air duct for air outlet 110881 115881 120881 1258812Flexible connection for air
outlet 110870 115870 120870 125870
3Leaving air rectifier 110840 115840 120840 1258404Inlet air angle 90° 110850 115850 120850 1258505Air duct for air inlet 110880 115880 120880 1258806Flexible connection for air
inlet 110860 115860 120860 125860
7Inlet air grille 110830 115830 120830 125830
Replacement filter mat for inletair grille 110820 115820 120820 125820
-
10
1.51 Door air curtainsControls
Fan control · Wiring · Remote radio control
Remote radio controller, integral, type _ _ _ _ _ _-00W
All Kampmann door air curtains can be operated with a wireless,factory-fitted radio controller instead of with a stage switch. � Transmitter accommodated within plastic housing RAL 9010,
80 x 80 x 15 mm� Simple wall-mounting without the need for cabling� 3-stage fan speed push-button control� Summer/winter control is also possible� Receiver unit fitted on unit� Aerial included
Fan control The fans used in Kampmann Vario door air curtains can be switched between 5 fan speeds by means of integral transformers. When operated with 3-stage switches, any of thefive switching stages can be selected. The summer/winter switches allow ventilation to be provided in summer, withouthot water supply, using thermoelectric shut-off valves.
Vario door air curtains, with one fan group, can be operatedwith 3- or 5-stage switches.
Wiring
Please refer to page 11 for wiring details. Electrical ratings aregiven in the technical data pages 30 - 36. The measured valuesare the maximum values under poor conditions. The actualvalues can be even lower, depending on the location of the units,the accessories used and the level of dirt on the filter. Wiringshould be done in accordance with German Electrical Association(VDE) and energy supply company directives.
Cascade module
Up to 10 door air curtains can be operated in parallel with onestage switch using a cascade module (see Table).
Number of cascade modules when operating door aircurtains in parallel (maximum 10 units)
No. of Vario door air curtains 1 2 3 4 5 6 7 8 9 10
No. of cascade modules whenstage switches are used 0 1 2 2 3 3 4 4 5 5
Article no. for remote radio controller Datanorm/EDVinput: 151 000 _ _ _ _ _ _ -00W (Insert type no.)
Remote radio controller for door air curtains
Transmitter Receiver aerial
*
*Insert door air curtain basic unit type number
Cont
rols
-
11
Cabling
Cont
rols
1.51 Vario door air curtainsControls
Cabling
Operation of a single Vario door air curtain
3-stage switch,surface-mounted, type 100917
A*
3Mains230 V/50 Hz,fuses to be provided on site
Parallel operation of Vario door air curtains
*See the table below for the number of wires for the cables designated with a letter. The number of wires for all other cables are given on the wiring diagram itself.
The figure in brackets applies when a frost protection thermostat is used (only required when used in unheated rooms).
Number of wires including fuse
Cable 3-stage switch,type 100917/1009183-stage summer/winter switch,
type 100920/1009225-stage summer/winter switch,
type 100925/1009265-stage summer/winter switch,
type 100928/100929
A 5 6 8 8B 6 (9) 7 (10) 9 (12) 9 (12)
Vario door air curtain
Vario door air curtain
5-stage switchflush-mounted, type 100926
Cascade module,type 100906
Vario door air curtain
Mains230 V/50 Hz,fuses to be provided on site
to nextcascade module
DDC activation of doorcontact etc.
B*
3
B*
A*
A* 3 3
3
A*
-
12
Cont
rols
1.51 Vario Door air curtainsControls
Accessories: 3- and 5-stage switches · Cascade modules
Article no. for DataNorm/EDV entry Controls accessories: 196 000 _ _ _ _ _ _(Insert type)
3- and 5-stage switches · Cascade modules
3-stage switch 0-1-2-3, surface-mounted, type 100917
Housing plastic, white, JungSwitching capacity 10 AProtection class IP 21Dimensions H x W x D: 82 x 82 x 59 mm
3-stage switch 0-1-2-3, flush-mounted, type 100918
Assembly in a 55 mm junction boxCover white, Jung
Switching capacity 10 A
Dimensions H x W x D: 82 x 82 x 24* mm
3-stage summer/winter switch 0-1-2-3, surface-mounted, type 100920
Housing plastic, light/dark grey, insulatedSwitching capacity 15 AProtection class IP 55Dimensions H x W x D: 82 x 82 x 125 mm
3-stage summer/winter switch 0-1-2-3, flush-mounted, type 100922
Assembly in a 55 mm junction boxCover whiteSwitching capacity 15 ADimensions H x W x D: 82 x 82 x 24* mm
5-stage switch 0-1-2-3-4-5, surface-mounted, type 100925
Housing plastic, light/dark grey, insulatedSwitching capacity 15 AProtection class IP 55Dimensions H x W x D: 82 x 82 x 125 mm
5-stage switch 0-1-2-3-4-5, flush-mounted, type 100926
Assembly in a 55 mm junction boxCover whiteSwitching capacity 15 ADimensions H x W x D: 82 x 82 x 24* mm
5-stage summer/winter switch 0-1-2-3-4-5, surface-mounted, type 100928
Housing plastic, light/dark grey, insulatedSwitching capacity 15 AProtection class IP 55Dimensions H x W x D: 82 x 82 x 125 mm
5-stage summer/winter switch 0-1-2-3-4-5, flush-mounted, type 100929
Assembly in a 55 mm junction boxCover whiteSwitching capacity 15 ADimensions H x W x D: 82 x 82 x 24* mm
Cascade module, surface-mounted, type 100906
Housing plastic, light greyProtection class IP 65Dimensions H x W x D: 179 x 255 x 72 mm
3-stage switch, surface-mounted, type 100917
3-stage summer/winter switch, flush-mounted type 100922
5-stage switch, flush-mounted, type 100926
5-stage summer/winter switch, surface-mounted, type 100928
-
13
Article no. for DataNorm/EDV entry Frost protection thermostat, fitted: 151 000 _ _ _ _ _ _
Cont
rols
1.51 Vario Door air curtainsControls
Accessories: Control valves • Frost protection thermostats
Control valves
Outlet temperatures that are too high reduce the penetration depth of the door air curtain air stream. The outlet temperature shouldalso not exceed 40 °C for energy-saving reasons. The use of a leaving air temperature limiting valve means that it is possible to maintain the controller at a constant value. In summer mode, an additional thermoelectric shut-off valve is used to prevent the air stream heating up.
*Insert door air curtain basic unit type
(Insert type)
Control valves · Frost protection thermostat
Leaving air limiting valve Available as a straight or angled valve body with a thermostatic head and remote sensorwith a 2 m capillary tube to control the leaving air temperature at a constant value; the valvecomes complete with fixings for mounting the sensor in the air stream; temperature settingrange 20-50 °C
Model Vario door air curtainhorizontal Type 100965, 3/4“, angled
vertical Type 100960, 3/4“, straightstanding Type 100966, 1“, straight
Thermoelectric shut-off valveAvailable as an angled or straight valve body with a thermoelectric actuator 230 V, 50 Hz(closed in a de-energised state); for use with 3- and 5-stage summer/winter switches(type 100920, type 100922, type 100928, type 100929) or 5-stage controller type200925, to close off the heating circuit in summer
Model Vario door air curtainhorizontal Type 100910, 3/4“, angled
vertical Type 100900, 3/4“, straightstanding Type 100911, 1“, straight
Frost protection thermostat, loose, type 030268, fitted type _ _ _ _ _ _ -FOnly required when door air curtains are fitted in unheated rooms (porches or vestibules)where a thermoelectric shut-off valve is used; the unit is fitted to the leaving air side of theheat exchanger and set to approximately +8 to +10 °C (minimum +5 °C); should thetemperature fall below this pre-set value, the fan is switched off and the thermoelectricshut-off valve is opened. Once the temperature rises above the pre-set value, the fan startsup again automatically; with integral filter monitoring, 3 m capillary tube, setting range-10/+12 °C, switching capacity 8 A
Housing galvanised sheet steelSensor copper, gas-filledProtection class IP 40Protection class IContact potential-free changeover contact 24-250 V AC/15(8) ASetting range -10 to +12 °CSwitching differential 1 kelvinDimensions W x H x D: 105 x 112 x 55 mm
Leaving air temperature limiting valve,type 100966
Leaving air temperature limiting valve,type 100965
Thermoelectric shut-off valvetype 100911
Thermoelectric shut-off valve, type 100910
Frost protection thermostat, type 030268
*
-
14
Cont
rols
1.51 Vario Door air curtainsControls
BUS controller with the KaBUS ECO system
BUS Controller with the KaBUS ECO system
The KaBUS ECO control system has been designed as a multi-functional control system for door air curtains. Up to eight unitscan be controlled via a BUS cable using the operating unit. Allthe electronics are concealed on the door air curtainsthemselves. The system can be configured for summer and/orwinter mode. In addition to controlling the waterside valves, itis also possible to set a 4-stage fan mode, optionally withdemand-led fan speed increase.
Operating unit,type 31026
Room temperature sensor,type 31056
(alternative)
Industrial room sensor,type 31057
Vario door air curtain Vario door air curtain
Timer, DDC etc. activation
Mains 230 V/50 Hzfuses by others
Door contact, movementsensor etc. activation
Fault or operational alert24 V AC
Mains 230 V/50 Hzfuses by others
Door contact, movementsensor etc. activation
Fault or operational alert24 V AC
to next door aircurtain(max. 8 Varioper operatingunit)
2*
2*
2* 2* 2*
2*
4*
3 2* 2* 2*3
The number of wires (incl. fuse) to beconnected is shown for each cable. Thecables designated with a * are shieldedcontrol cables, stranded in pairs e.g.Cad. 5 (AWG 23). The cabling paths shouldbe kept as short as possible. Control cablesshould be laid separately from heavycurrent cables.
Room temperature controller and fan run-on function areincluded. The operating unit, with integral room temperaturesensor, is very user-friendly. It is possible to control it fromexternal timers, movement alarms or DDC equipment
Article no. for DataNorm/EDV entry Controls accessories196 000 _ _ _ _ _ _(Insert type)
-
*Insert door air curtain basic unit type
1.51 Vario Door air curtainsControls
BUS controller with the KaBUS ECO system
15
Article no. for DataNorm/EDV entry 196 000 _ _ _ _ _ _ KaBUS ECO power module: 151 000 _ _ _ _ _ _ -00B
(Insert type)(Insert type)
Cont
rols
BUS controller with the KaBUS ECO system
KaBUS ECO operating unit, type 031026The KaBUS ECO operating unit serves to control the system, including fan stage, fanspeed increase, room temperature set values, fan run-on time, summer/winter mode.An integral operating LED displays the operating mode.
Housing white, surface-mounted on a 55 mm back boxRoom temperature set point 5 - 25 °CSwitching differential +/- 0.8 K
Fan run-on time- without room temperature controller- with room temperature controller
0 - 10 min adjustable2 min fixed
Digital input external activation i.e. timerProtection class IP 30Protection class III (safety low voltage)Dimensions W x H x D: 70 x 70 x 26 mm
KaBUS ECO Power module, fitted, type _ _ _ _ _ _ -00BThe KaBUS ECO power module is factory-fitted on the door air curtain and serves tocontrol the valve and the fan group that can be switched between 4 stages. Thedifferent operating programmes are selected by the DIP switched integrated within thepower module. Not suitable for use with door air curtains with remote radio control.
Housing steel Voltage 230 V AC/50 HzFan switching output 230 V AC/50 Hz 10 A inductiveValve switching output 230 V AC/50 Hz 3 A inductiveOperation/fault switching output 24 V DC/30 mADigital input frost alertDigital input door contact/movement alert etc.Protection class IP 20Dimensions W x H x D: 207 x 185 x 75 mm
Room temperature sensor type 031056
The separate room temperature sensor type 031056 is required if the roomtemperature sensor integrated within the operating unit cannot be used for anyreason, possibly because of a poor fixing location.
Housing white, surface-mounted in a 55 mm back boxMeasuring range 0 to 51 °CProtection class IP 20Protection class III (safety low voltage) Dimensions W x H x D: 70 x 70 x 26 mm
Industrial room sensor type 031057For use in areas where there is a high concentration of dust or high levels of humidity.
Housing surface-mounted on the wallMeasuring range 0 to 51 °CProtection class IP 54Protection class III (safety low voltage) Dimensions B x H x T: 70 x 70 x 26 mm
Thermoelectric shut-off valve and frost protection thermostat see p 13; also availableFrost prot. thermostat and KaBUS ECO power module, fitted, type _ _ _ _ _ _ -F0BFrost prot. thermostat and remote radio controller, fitted type _ _ _ _ _ _ -F0W
KaBUS ECO operating unit type 031026
KaBUS ECO power module type _ _ _ _ _ _-00B*
*
Room temperature sensor type 031056
Industrial room sensor, type 031057
**
-
0 3 6 points
normal, protected slightly built-up free-standing,unprotected
0 1 2 points
Zone I Zone II Zone III
Hm
ax. (
Wm
ax.)
[m]
Points total
3.0
2.5
2.00 5 10 15 20 25 30 35 40
16
Selection processPoints should be allocated according to the circumstances onsite, in terms of the different influencing factors/evaluationcriteria as per the above scale.� Intermediate figures are possible.� Extreme cases for certain influencing factors beyond the scale
can also be taken into account. The sum of the points in theright-hand column gives the points total for determining themaximum discharge heights and widths according to theswitching stages given on Diagram 1.
� The limit values (see p 19) should be observed with doors thatare constantly open
� Hmax.: Maximum discharge height for Vario horizontal andvertical
� Wmax.: Maximum discharge width for Vario standing, singleside
1.51 Vario Door air curtainsDesign information
Selection process
Evaluation criteria Pressure conditions/requirements/environment Points
Wind pressure conditions
0 3 6 points
slight air flow moderate air flow serious air flowheavily built-up area coast, hillside
points
Passage/Porch
0 2 4 points
present, closed open not present points
Position of the building points
Area constantly used by people
B = door width
points
Pressure conditions due to mechanical ventilation
0 2 4 points
excess pressure equalised pressure slight low pressure
0 2 4 points
none at the side of the doorway opposite doorway
0 2 4 points
up to2.5 m 3.5 m above 4.5m or with stair access
0 2 4 points
up to 100 m2 400 m2 above 800 m2
0 3 6 points
a = 0 300 mm 600 mm
points
Other thoroughfares/doorways points
Room height points
Floor area points
Distance from air outlet to
doorway
1 = Door air curtain, 2 = Door, a = distance
points
*Intermediate figures are possible Points total points
Diagram 1
III II I
B
standing
BB 2
2xB
1
2
12
Des
ign
info
rmat
ion
Vario stage 5
Vario stage 4
Vario stage 3
-
1.51 Vario Door air curtainsDesign information
Selection example
17
0 3 6 points
normal, protected slightly built-up free-standing,unprotected
0 1 2 points
Zone I Zone II Zone III
Selection example:Given: Door air curtain for sales room, door height 2.20 m, width 2.00 m� Slight air flow (wind)� Porch or passage - present� Normal, protected position� Sales staff in zone II� Slight excess pressure in the room� Side thoroughfare� Room height 3.50 m� Floor area 200 m2� Distance from air outlet to doorway 100 mm
Selection:� Door air curtain model 20, so that unit length = door width� Evaluation see table: points total 9� Discharge height = Door height + a
= 2.2 m + 0.1 m = 2.3 m � From diagram 1: Minimum requirements with 9 points:
Vario door air curtain, fan stage 4 with Hmax. = 2.30 m� Result: Vario door air curtain, model 20
Evaluation criteria Pressure conditions/requirements/environment Points
Wind pressure conditions
0 3 6 points
slight air flow moderate air flow serious air flowheavily built-up area coast, hillside
points
Passage/Porch
0 2 4 points
present, closed open not present points
Position of the building points
Area constantly used by people
B = door width
points
Pressure conditions due to mechanical ventilation
0 2 4 points
excess pressure equalised pressure slight low pressure
0 2 4 points
none at the side of the doorway opposite doorway
0 2 4 points
up to 2.5 m 3.5 m above 4.5 m or withstair access
0 2 4 points
below 100 m2 400 m2 above 800 m2
0 3 6 points
a = 0 300 mm 600 mm
points
Other thoroughfares/doorways points
Room height points
Floor area points
Distance from air outlet to
doorway
1= Door air curtain, 2 = door, a = distance
points
*Intermediate figures are possible Points total points
III II I
B
standing
Ba
B 2
2xB
1
2
12
1
0
0
1
1
2
2
1
1
9
Hm
ax. (
Wm
ax.)
[m]
Points total0 5 10 15 20 25 30 35 40
Diagram 1
a
Des
ign
info
rmat
ion
3.0
2.5
2.0
Vario stage 5
Vario stage 4
Vario stage 3
-
18
1.51 Vario Door air curtainsDesign information
Unit selection • Possible combinations
1. Calculation based on the max. discharge height� Max. discharge height H = Door height + a
The following should also be taken into consideration:� Fan stage� Wind pressure conditions� Influence of passages/porch/position of the building� Areas used by people� Pressure conditions due to mechanical ventilation etc.
2. Calculation based on discharge width and door height(Vario, standing unit)
see Diag. 2.
Unit selection
The following should be considered when selecting a unit:� Door width/height (standing model)� Max. discharge height H� Max. discharge width (standing model)
Door width1.0 m 1.5 m 2.0 m 2.5 m 3.0 m 3.5 m 4.0 m 4.5 m
Model 10 Model 15 Model 20 Model 25 2 x Model 15Model 20 + Model15
2 x Model 20 Model 20 + Model 25Model 25 + Model 10
Selection based on max. discharge height H1): 2.3 - 3.0 m
Combination options
Door width = Unit length B
1)With average to good pressure conditions/requirements/environment2)Shown up to door width 4.5 m, other widths are possible by combining units
3. Calculation based on door widthSelecting the required unit based on the door width: � Door width = Unit length BThe lengths of the units are based on common doordimensions. Other lengths can be achieved by combining basicunits of the same or different sizes or with the use ofappropriate casing extensions (see table below).
Vario door aircurtain - standing one-side both sides
Max. dischargewidth:
Wmax. =door width
+ a
Wmax. =
+ adoorwidth 2
Arrangement
Vario door air curtain horizontal/vertical
Max. discharge height: Hmax. = door height + a
2.
1.
3.
Des
ign
info
rmat
ion
Unit len
gth B
Door wi
dth
-
Frost protectionIf door air curtains are used in unheated rooms, such as porches,a frost protection thermostat is required to prevent the heatexchanger from freezing. This switches the fans off if there is arisk of frost, and opens the thermoelectric shut-off valve, shouldone be used (see p 13).
The frost protection thermostat is factory-fitted on the doorair curtain, if the suffix -F is added to the end of the door aircurtain type no.; it can also be supplied separately.
19
1.51 Vario Door air curtainsDesign information
Arrangement • Limits of use • Frost protection • Low temp. operation • Sound pressure levels
1 Vario door air curtain, basic unit - horizontal
2 Inlet grille
3 Flexible connection6 Air inlet angle section7 Leaving air rectifier8 Inspection opening (on site)
Unit shown installed within a supended ceiling
2
3
1
6
3
78
Low temperature operation Modern low temperature and condensing boilers work mostefficiently with low flow temperatures. Kampmann Vario door aircurtains have high-output copper/aluminium heat exchangers andare ideal for use in low temperature mode with a flowtemperature of approx. 50 °C. The very low water content andfan operation with high air flows mean that they react veryquickly to longer cool-down times.
Sound pressure level
The aerodynamic construction of the Vario door air curtain hasa very low noise level in spite of high outlet air velocity. It shouldnevertheless be borne in mind that the noise level can be ratherannoying at higher fan speeds. The sound pressure levels aregiven in the technical data tables.
The sound pressure levels quoted have been calculated in ananechoic room with medium absorption at a distance of 3 mfrom the air inlet. As the actual sound pressure level is seriouslydependent on the acoustic properties of the room, the givenvalues can vary in practice. There can be increase in soundpressure level of up to 3-6 dB (A) with acoustically poorconditions, such as reverberant ceilings, closed doorways andpoor absorption surfaces. If two door air curtains of the samemodel are arranged side by side, the sound pressure levelincreases by approximately 2-3 dB (A).
Frost protection thermostat, refer to p 13 for description
Arrangement
When door air curtains are arranged above the door (horizontaland vertical models), the units must be mounted in such a waythat the outlet air grille sits as closely as possible to the dooropening, and preferably directly adjacent to it. When arrangedbeside the doorway (standing models), it must also be ensuredthat the outlet air grille is positioned as closely as possible to thedoor opening.
Where there is a horizontal or vertical gap of more than around500 mm between the door opening and the outlet grille, thenext unit length up should be selected or side panels, notdissimilar to a corridor, have to be fitted.
Limits of use
Extremely poor operating conditions, such as� serious low pressure in the room, caused by mechanical
ventilation without the supply of external air,� extremely poor weather conditions, with high wind speeds in
an unsheltered position,� several open thoroughfares outside, particularly if they are
located opposite each other,
can impair the effective screening effect of the door air curtains.Additional measures may be required to compensate for this. Itshould be taken into consideration when designingthoroughfares, that it may be necessary to close the doors evenduring business hours.With standing door air curtains, the use of units on both sides ofthe door may be required with poor installation conditions.
Should doors, say in large department stores, have to be open,even in poor or extreme weather conditions, then units with asignificantly higher air volume and heat output should be used.They must be capable of heating up the larger volumes of coldair.
Des
ign
info
rmat
ion
-
Calculation examplegiven: Vario door air curtain, model 15
horizontal, type 115330Flow temperature tw1 = 65 °CReturn temperature tw2 = 55 °C Leaving air temperature tL1 = 18 °C
required: Heat output Q at fan stage 5Leaving air temperature tL2Water pressure R
Calculation
from diagram 2: f = 0.81
from table on p 31: Qn = 17360 w(LPHW 75/65 °C, tL1 = 20 °C)
V = 2130 m3/h
from diagram 3, p 21, Vario door air curtain, model 15
from diagram on p 17: R = 6.7 kPa
ResultHeat output Q = 14062 wLeaving air temperature tL2 = 37.4 °CWater pressure R = 6.7 kPa
m• = Q • 0,86 (4) m• = 14062 • 0.86 = 1209 l/h+tw 10
Keytw1 [°C] = Flow temperaturetw2 [°C] = Return temperature+ t [K] = Average excess temperature+tw [K] = Water temperature differencetL1 [°C] = Entering air temperatureQ [W] = Heat output Qn [W] = Nominal heat output at
LPHW 75/65 °C, tL1 = 20 °Cf [/] = Heat output correction factorm• [l/h] = Water flow rateR [kPa] = Water pressureV [m3/h] = Air volumeC [Wh/m3K] = Multiplier for outlet air temp. calculation
= 0.34 wh/m3K
Conversion to other flow and return temperaturesHeat outputs for different water temperatures can be found inthe technical data tables on pages 30 to 35.
The following formulae and heat output correction factors fromDiagram 2 can be used to calculate the heat output with watertemperatures which are not listed in the tables.
Calculation formulae
Heat output correction factor Diagram 2
Q = Qn • f (3)
+tw = tw1 – tw2 (2)
tL2 = tL1 + Q (5)
+t = tw1 + tw2 - tL1 (1)2
tL2 = tL1 + Q (5) tL2 = 18 + 14062 = 37.4 °CV• c 2130 • 0.34
======
=====
=====
m• = Q • 0,86 (4)+tw
+t = tw1 + tw2 – tL1 (1) +t = 65 + 55 – 18 = 42 K2 2
+tw = tw1 – tw2 (2) +tw = 65 – 55 = 10 K
Q = Qn • f (3) Q = 17360 W • 0.81 = 14062 w
1.51 Vario Door air curtainsDesign information
Conversion to other flow and return temperatures
20
V • c
Des
ign
info
rmat
ion
Hea
t ou
tput
cor
rect
ion
fact
or
Average excess temperature
-
Vario door air curtains, horizontal/vertical · Water pressure Diagram 3W
ater
pre
ssur
e R
[kPa
]
Water flow rate m• [l/h]
Vario door air curtain, standing model · Water pressure Diagram 4
Wat
er p
ress
ure
R [k
Pa]
Water flow rate m• [l/h]
Water pressureThe water pressure can be calculated from Diagram 3 for therespective horizontal and vertical door air curtain sizes and fromDiagram 4 for standing unit sizes.
The flow rate can be calculated using the formulae on p 20. Thepressure diagrams apply for LPHW with an average watertemperature of 70 °C.
There must be hydraulic balancing when used together withconventional heating units.
1200 300 500 1000 2000 3000 5000
2
3
4
10
20
30
50
1200 300 500 1000 2000 3000 5000
2
3
4
10
20
30
50
Model
10
Model
15Model
20
Model
25
Model
30Model
35Mo
del 20
Model
25
1.51 Vario Door air curtainsDesign information
Water pressure
21
Des
ign
info
rmat
ion
-
1Vario door air curtain, basic unit,horizontal model
2Air duct for air outlet3Flexible connection for air outlet4Leaving air rectifier5 Inlet air angle section 90°6Air duct for air inlet7Flexible connection for air inlet8 Inlet air grille
Air outlet
Air outlet Air outlet
Air inlet Air inlet
Air inlet
*Two sets of sheet steel components are supplied for door air curtain models 20 and 25.All dimensions are given in mm
Model 10 15 20 25
a 730 1230 1730 2230b 870 1370 900* 1150*c 840 1340 870* 1120*d 855 1355 885* 1135*e 200 220 200 212,5f 730 1230 820* 1070*g 700 1200 790* 1040*h 715 1215 805* 1055*i 200 220 200 212,5k 884 1384 884* 1134*l Please state dimension with orderm 954 1454 954* 1204*n 884 1384 884* 1134*o 954 1454 954* 1204*p 210 210 210 210q 110 110 110 110r - - 1920 2420s 920 1420 920* 1170*
Overall dimensions
Opening dimensions
Installation within a suspended ceiling
bc
de ee135 135
7,57,5
fg
hi ii65 65
7,57,5
110
8021
018
0
195
7,57,5 50
5011
095
7,57,5 55
55
Horizontal model
2
3
1
4
5
7
8
6
1.51 Vario Door air curtainsTechnical data
Sheet steel components for horizontal and vertical units
22
Tech
nica
l dat
a
Dimensions of sheet steel components
-
23
All dimensions aregiven in mm
1.51 Vario Door air curtainsTechnical data
Dimensions of models 10 and 15 • horizontal
Tech
nica
l dat
a
Dimensions of models 10 and 15,horizontal
Basic unit with casing, top view
1 Inlet air grille2 Filter G23 Heat exchanger (copper/aluminium)4 Radial fan5 Leaving air rectifier6 Casing outline7 Electrical terminal box for thermoelectric
shut-off valve
8 Transformer9 Electrical connectionbl Flow connection 3/4”bm Return connection 3/4”bn Air vent and drain cockbo Fixing holesbp Connecting angle section for casing extensionbq Outline of basic unit casing end panel
Basic unit without casing, view from below Model 10 is shown
Model 10 15
A 1000 1500B 880 1380C 730 1230D 880 1380
2
3
4 47
6
89
1
1
8
bobl
bo bo
bo
9
23
1
4
5
bm
bn
bn
bl
1
bo
bo
bo
bo
bl
Basic unit casing, view from below Casing extension
1 1
5 5
bp bq
Horizontal door air curtain with basic unit casing Cross-section through basic unit with casing
Basic unit casing, view of air inlet
-
Side view of basic unit with casing
Basic unit casing, view from below Casing extension
Basic unit with casing - top view
Basic unit casing, view of air inlet
All dimensions aregiven in mm
Basic unit without casing, view from belowModel 20 shown
Door air curtain, horizontal with basic unit casing
1 Inlet air grille2 Filter G23 Heat exchanger (copper/aluminium)4 Radial fan5 Leaving air rectifier6 Casing outline7 Electrical terminal box for thermoelectric
shut-off valve
8 Transformer9 Electrical connectionbl Flow connection 3/4”bm Return connection 3/4”bn Air vent and drain cockbo Fixing holesbp Connecting angle section for casing extensionbq Outline of basic unit casing end panel
24
7
8
5
bm
bn
1
bl
bn
1 1
1 1
8bo
bo
bo
bobl
9
1 1
5 5
1
1
8bo
bo
bo
bo
bl
2 23
4 4 4 4
9
7
6
8
1 1
5 5
bp bp bq
Model 20 25
A 2000 2500B 910 1160C 1730 2230D 1880 2380E 1000 1250
1.51 Vario Door air curtainsTechnical data
Dimensions of models 20 and 25 • horizontal
Tech
nica
l dat
a
Dimensions of models 20 and 25,horizontal
-
Model 10 15
A 1000 1500B 880 1380C 730 1230D 880 1380F 730 1230
25
Vertical door air curtain with basic unit casing Cross-section through basic unit with casing
Basic unit casing, view from behind Casing extension
Basic unit with casing, top view
Basic unit casing, view of air outlet
1 Inlet air grille2 Filter G23 Heat exchanger (copper/aluminium)4 Radial fan5 Leaving air rectifier6 Casing outline7 Electrical terminal box for
thermoelectric shut-off valvel 8 Transformer
9 Electrical connectionbl Flow connection 3/4”bm Return connection 3/4”bn Air ventbo Fixing holes for fitting with wall or ceiling bracketsbp Connecting angle for casing extensionbq Outline of basic unit casing end panelbr Fixing holes for fixing directly onto the wall
1
1
5
8
bo
bo
bl9
br
br
br
br
1
5
bp bq
2
3
1
5
bm
bn bn
bl
1bo
bo
bo
bo
All dimensions aregiven in mm
5
2
3
4 47
6
89
Basic unit without casing, front viewModel 10 shown
1.51 Vario Door air curtainsTechnical data
Dimensions of models 10 and 15 • vertical
Tech
nica
l dat
aerf
lur
Wan
d-/N
isch
e
Dimensions of models 10 and 15,vertical
-
1.51 Vario Door air curtainTechnical data
Dimensions of models 20 and 25 • vertical
26
Vertical door air curtain with basic unit casing Cross-section through basic unit with casing
Basic unit casing, view from behind Casing extension
Basic unit with casing, top view
Basic unit casing, view of air outlet
1 Inlet air grille2 Filter G23 Heat exchanger (copper/aluminium)4 Radial fan5 Leaving air rectifier6 Casing outline7 Electrical terminal box for
thermoelectric shut-off valve 8 Transformer
9 Electrical connectionbl Flow connection 3/4”bm Return connection 3/4”bn Air ventbo Fixing openings for fitting with wall or ceiling bracketsbp Connecting angle section for casing extensionbq Outline of basic unit casing end panelbr Fixing openings for mounting directly onto the wall
Basic unit without casing, front viewModel 20 shown
Model 20 25
A 2000 2500B 910 1160C 1730 2230D 1880 2380E 1000 1250F 820 1070
1
7
5
8
bn bn
bmbl
1 1
5 5
bp bp bq
2 2
3
4 4 4 4
5 5
1 1bo
bo
bo 8
79
bo
bl
8
1
1 1
1
5
9
5
6
bo
bo
br
br
br
br
All dimensions aregiven in mm
Dimensions of models 20 and 25,vertical
Tech
nica
l dat
a
-
27
1.51 Vario Door air curtainsTechnical data
Dimensions of models 20, 25 and 30 • standing
Tech
nica
l dat
ante
rflu
rW
and-
/Nis
che
1 Inlet air grille2 Filter G23 Heat exchanger (copper/aluminium)4 Radial fan5 Leaving air rectifier6 Casing outline
7 Electrical junction box for thermoelectric shut-off valve
8 Transformer9 Electrical connectionbl Flow connection 1“bm Return connection 1“bn Fixing holes
2
2
4
4
4
4
7
6
98
8
bl
9
1
1
3
1
1
5
5
bn bn
bn bn
*For dimensions of model 30 see table p 28
Model 20 25 30
A 2000 2500 2940
B 910 1160 1380
C 1730 2230 *D 1880 2380 *E 1000 1250 1470
2
3
1
4
5bm
bl
1
1
5
5
Door air curtain, standingwith basic unit casing,models 20, 25, 30
Basic unit casing,view of air inlet,models 20, 25, 30
Basic unit casing,view of air outlet,models 20, 25, 30
Cross-section through basic unit with casing
Basic unit with casing,view from behind,models 20, 25
Basic unit without casing, front view, models 20, 25Model 20 shown
Shown positionedon left side of door-way
All dimensions aregiven in mm
Dimensions of models 20, 25 and 30,standing
-
28
1.51 Vario Door air curtainsTechnical data
Dimensions of models 30 and 35 • standing
Standing door air curtain with basic unit casing,model 35
Basic unit with casing,view from behind, models 30 and 35
Basic unit without casing,front view, models 30 and 35
Basic unit casing,view of air outlet, model 35
Basic unit casing, view of air inlet, model 35
Basic unit with casing, top view
Model 35 Model 35Unit shownpositioned on theright-hand side ofthe doorway
Refer to p. 36 for further views of model 30
*For dimensions of model 30 see table p 27
Model 30 35
A * 3440B * 910C 1230 1730D 1380 1880E * 1970F - 1470G - 1380H 1230 1230J 1380 1380
1 Inlet air grille2 Filter G23 Heat exchanger (copper/aluminium)4 Radial fan5 Leaving air rectifier6 Casing outline7 Electrical terminal box for thermoelectric shut-off valve
8 Transformer9 Electrical connectionbl Flow conection 1“bm Return connection 1“bn Fixing holes
1
75
8
bm
bl
1
1
1
5
5
5
3
3
4
4
4
4
4
4
4
7
6
8
9
1
1
1
5
5
5
5
5
5
8
bn bn
9
bn bn
bn
bl
bn
bn bn
2
2
All dimensions aregiven in mm
Tech
nica
l dat
a
Dimensions of models 30 and 35,standing
-
29
1.51 Vario Door air curtainsTechnical data
Dimensions of model sizes 10, 15, 20, 25, without heat exchanger, horizontal
1 Inlet air grille2 Filter G23 Radial fan4 Outlet air rectifier5 Casing outline6 Transformer
7 Electrical connection8 Fixing holes for wall or ceiling
brackets
Model 10 15 20 25
A 1000 1500 2000 2500B 880 1380 910 1160C 730 1230 1730 2230D 880 1380 1880 2380E - - 1000 1250
All dimensions are given in mm
All illustrations show model size 20 by way of example. Dimensions of other modelsizes are shown in the Vario Door air curtain catalogue on pages 23-24
Door air curtain, horizontal with basic unit casing Cross-section through basic unit with casing
Basic unit casing, view from below Side view through basic unit with casing
Top view of basic unit with casing
Basic unit casing, view of air inlet
Basic unit with casing, view from below
4
5
8
8
8
8
8
8
8
8
1
1
2
1 1
1
1
1 1
2 2
3 3 3 3
4 4
4
3
6
6
1 1
6
6
7 7
Tech
nica
l dat
ater
flur
Wan
d-/N
isch
e
Dimensions of model sizes 10,15, 20 and 25, without heat exchanger,horizontal
-
30
1.51 Vario Door air curtainsTechnical data
Heat outputs for model size 10 • horizontal and vertical
Vario Door air curtain 10 horizontal vertical
Basic unitBasic unit casingCasing extension
TypeTypeType
110330110800110810
110331110801110811
Dimensions Length(incl. casing) Height
Depth
mmmmmm
1000260650
1000650260
Max. discharge height H max1)
Max. door widthmm
2.3 - 3.01.0
2.3 - 3.01.0
Weight without/with casing kg 33/55 33/55
Water content l 1.0 1.0
Connections inch 3/4“ 3/4“
Switching stage2) 5 4 3 2 1
Air volume m3/h 1390 1220 1050 920 600
Electrical power consumption3)
Current consumption3)
Sound pressure level -at a distance of 3m
WA
dB(A)
3921,6857
3131,3554
2381,0550
2020,9147
1130,5436
Heating medium
Entering
air
temp.
tL1 [°C]
Heat outputs
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
LPWW 55/45 °C
14
16
18
20
22
7083
6638
6194
5751
5308
28,7
29,9
31,0
32,2
33,3
6680
6261
5842
5424
5006
29,8
30,9
32,0
33,1
34,1
6226
5835
5445
5055
4666
31,1
32,2
33,2
34,2
35,1
5829
5463
5098
4733
4368
32,3
33,3
34,2
35,1
36,0
4622
4332
4042
3753
3464
36,3
37,0
37,7
38,4
39,1
LPHW 70/55 °C
14
16
18
20
22
9596
9146
8695
8244
7792
34,0
35,1
36,3
37,4
38,6
9050
8626
8201
7775
7348
35,4
36,6
37,7
38,7
39,8
8435
8040
7644
7247
6849
37,2
38,3
39,3
40,3
41,3
7897
7527
7156
6784
6412
38,8
39,8
40,7
41,7
42,6
6262
5968
5674
5380
5085
44,2
44,9
45,7
46,4
47,1
LPHW 70/60 °C
14
16
18
20
22
10417
9973
9528
9083
8639
35,7
36,9
38,0
39,2
40,4
9825
9405
8986
8567
8147
37,3
38,4
39,5
40,7
41,8
9157
8767
8376
7985
7594
39,2
40,3
41,3
42,4
43,4
8573
8207
7841
7475
7109
40,9
41,9
42,9
43,9
44,9
6798
6508
6218
5928
5637
46,7
47,5
48,3
49,1
49,8
LPHW 75/65 °C
14
16
18
20
22
11527
11083
10639
10195
9750
38,0
39,2
40,4
41,6
42,8
10871
10453
10034
9615
9196
39,8
40,9
42,0
43,2
44,3
10133
9743
9353
8962
8571
41,9
43,0
44,0
45,1
46,2
9486
8121
8756
8390
8024
43,8
44,8
45,8
46,8
47,8
7522
7233
6943
6653
6363
50,2
51,0
51,8
52,6
53,4
LPHW 82/71 °C
14
16
18
20
22
12966
12524
12081
11638
11194
41,0
42,2
43,4
44,6
45,8
12229
11812
11394
10976
10558
43,0
44,1
45,3
46,5
47,6
11398
11009
10620
10231
9841
45,4
46,5
47,6
48,7
49,7
10671
10307
9942
9578
9212
47,5
48,6
49,6
50,6
51,6
8462
8173
7884
7595
7305
54,8
55,6
56,4
57,2
58,0
LPHW 90/70 °C 20 11924 45,2 11246 47,1 10482 49,4 9813 51,4 7781 58,1
1)With average to good pressure conditions/requirements, see pages 16 and 172)With 3-stage switches, any 3 of the 5 stages can be selected3)For measuring values, see information on p 10
20
Article no. for DataNorm/EDV entry: 151 000 _ _ _ _ _ _(Insert type)
Tech
nica
l dat
a
-
31
1.51 Vario Door air curtainsTechnical data
Heat outputs for model size 15 • horizontal and vertical
Vario Door air curtain 15 horizontal vertical
Basic unitBasic unit casingCasing extension
TypeTypeType
115330115800115810
115331115801115811
Dimensions Length(incl. casing) Height
Depth
mmmmmm
1500260650
1500650260
Max. discharge height H max1)
Max. door widthmm
2.3 - 3.01.5
2.3 - 3.01.5
Weight without/with casing kg 50/83 50/83
Water content l 1.8 1.8
Connections inch 3/4“ 3/4“
Switching stage2) 5 4 3 2 1
Air volume m3/h 2130 1880 1610 1400 930
Electrical power consumption3)
Current consumption3)
Sound pressure level- at a distance of 3m
WA
dB(A)
5732,4858
4561,9855
3461,5151
2981,3248
1640,7837
Heating medium
Entering
air
temp.
tL1 [°C]
Heat outputs
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
LPWW 55/45 °C
14
16
18
20
22
12060
11304
10548
9793
9038
30,4
31,4
32,5
33,5
34,6
11074
10379
9685
8992
8299
31,0
32,0
33,1
34,1
35,1
9941
9318
8695
8072
7450
31,8
32,8
33,8
34,7
35,7
9008
8443
7878
7314
6751
32,6
33,5
34,5
35,4
36,3
6692
6272
5853
5434
5015
34,8
35,6
36,4
37,2
38,0
LPHW 70/55 °C
14
16
18
20
22
16340
15574
14806
14038
13267
36,2
37,3
38,3
39,4
40,4
15003
14300
13595
12889
12182
37,1
38,1
39,1
40,2
41,2
13469
12838
12205
11571
10936
38,2
39,2
40,2
41,1
42,1
12204
11632
11059
10485
9909
39,2
40,2
41,1
42,0
42,9
9067
8642
8216
7789
7362
42,2
43,0
43,8
44,6
45,4
LPHW 70/60 °C
14
16
18
20
22
17738
16981
16224
15467
14710
38,1
39,2
40,3
41,4
42,4
16287
15592
14897
14202
13507
39,0
40,1
41,2
42,2
43,3
14622
13998
13374
12750
12125
40,2
41,3
42,3
43,3
44,3
13249
12683
12118
11552
10987
41,4
42,3
43,3
44,3
45,2
9843
9423
9003
8583
8162
44,6
45,5
46,3
47,1
48,0
LPHW 75/65 °C
14
16
18
20
22
19628
18873
18117
17360
16603
40,6
41,8
42,9
44,0
45,1
18023
17329
16635
15940
15245
41,7
42,8
43,9
44,9
46,0
16180
15557
14934
14310
13686
43,0
44,1
45,1
46,1
47,1
14660
14096
13531
12966
12401
44,3
45,3
46,3
47,2
48,2
10892
10472
10053
9633
9213
47,8
48,7
49,6
50,5
51,3
LPHW 82/71 °C
14
16
18
20
22
22079
21326
20572
19817
19062
44,0
45,1
46,2
47,4
48,5
20273
19582
18889
18196
17503
45,2
46,3
47,4
48,5
49,5
18200
17579
16958
16335
15713
46,7
47,7
48,8
49,8
50,9
16491
15928
15365
14801
14237
48,0
49,1
50,1
51,1
52,1
12252
11834
11415
10996
10577
52,1
53,0
53,9
54,8
55,6
LPHW 90/70 °C 20 20304 48,0 18644 49,2 16737 50,6 15165 51,9 11267 55,6
1)With average to good pressure conditions/requirements, see pages 16 and 172)With 3-stage switches, any 3 of the 5 stages can be selected3)For measuring values, see information on p 10
20
Article no. for DataNorm/EDV entry: 151 000 _ _ _ _ _ _(Insert type)
Tech
nica
l dat
arfl
urW
and-
/Nis
che
-
32
1.51 Vario Door air curtainsTechnical data
Heat outputs for model size 20 • horizontal, vertical and standing
Vario Door air curtain 20
Basic unitBasic unit casingCasing extension
TypeTypeType
Dimensions Length(incl. casing) Height
Depth
mmmmmm
H max1), (Wmax)1)2)
Max. door width (door height)mm
Weight without/with casing kg
Water content l
Connections inch
Switching stage3) 5 4 3 2 1
Air volume m3/h 2820 2480 2140 1850 1210
Electrical power consumption4)
Current consumption4)
Sound pressure level- at a distance of 3m
WA
dB(A)
7543,2759
5982,6056
4541,9753
3931,7349
2151,0139
Heating medium
Entering
air
temp.
tL1 [°C]
Heat outputs
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
LPWW 55/45 °C
14
16
18
20
22
16811
15757
14703
13651
12599
31,2
32,2
33,2
34,2
35,2
15372
14408
13444
12482
11520
31,9
32,9
33,9
34,8
35,7
13855
12986
12118
11250
10384
32,7
33,6
34,6
35,5
36,4
12479
11696
10914
10133
9352
33,5
34,4
35,3
36,1
37,0
9123
8551
7979
7408
6837
35,8
36,5
37,3
38,0
38,7
LPHW 70/55 °C
14
16
18
20
22
22777
21709
20639
19568
18494
37,3
38,4
39,4
40,4
41,4
20827
19850
18872
17892
16911
38,3
39,3
40,3
41,2
42,2
18772
17892
17010
16127
15242
39,4
40,3
41,2
42,2
43,1
16907
16115
15321
14525
13728
40,4
41,3
42,2
43,1
44,0
12360
11781
11200
10619
10036
43,5
44,3
45,1
45,8
46,5
LPHW 70/60 °C
14
16
18
20
22
24726
23671
22616
21560
20505
39,3
40,4
41,4
42,5
43,5
22609
21645
20680
19714
18749
40,3
41,4
42,4
43,4
44,4
20379
19509
18639
17769
16899
41,5
42,5
43,5
44,4
45,4
18354
17571
16788
16004
15221
42,7
43,6
44,5
45,4
46,3
13418
12846
12273
11700
11127
46,1
46,9
47,7
48,4
49,2
LPHW 75/65 °C
14
16
18
20
22
27361
26308
25254
24199
23144
42,0
43,1
44,2
45,2
46,3
25018
24055
23091
22127
21162
43,2
44,2
45,2
46,2
47,2
22550
21682
20813
19944
19074
44,5
45,5
46,4
47,4
48,4
20310
19528
18746
17963
17180
45,7
46,7
47,6
48,6
49,5
14848
14276
13704
13132
12559
49,5
50,3
51,1
51,9
52,7
LPHW 82/71 °C
14
16
18
20
22
30777
29727
28676
27624
26571
45,5
46,6
47,7
48,8
49,9
28142
27182
26221
25259
24296
46,8
47,9
48,9
50,0
51,0
25366
24500
23634
22767
21899
48,3
49,3
50,3
51,3
52,3
22846
22067
21287
20506
19724
49,7
50,7
51,6
52,6
53,5
16702
16132
15562
14991
14419
53,9
54,8
55,6
56,4
57,3
LPHW 90/70 °C 20 28303 49,5 25880 50,7 23327 52,1 21010 53,4 15359 57,3
horizontal
120330120800120810
2000260650
2.3 - 3.02.0
68/106
2.63/4“
vertical
120331120801120811
2000650260
2.3 - 3.02.0
68/106
2.63/4“
standing
120332120802
---
6502000260
(2.3 - 3.0)(2.0)
68/106
2.6
1“
20
Article no. for DataNorm/EDV entry: 151 000 _ _ _ _ _ _(Insert type)
Tech
nica
l dat
a
1)H max. = max. discharge height, Wmax. = max. discharge width, with average to good pressure conditions/requirements, see p 16 and 172)If the max. discharge width (wide doorway) is exceeded, we would recommend positioning a unit on either side of the door..3)With 3-stage switches, any 3 of the 5 stages can be selected4)For measuring values, see information on p 10
-
33
1.51 Vario Door air curtainsTechnical data
Heat outputs for model size 25 • horizontal, vertical and standing
Vario Door air curtain 25
Basic unitBasic unit casingCasing extension
TypeTypeType
Dimensions Length(incl. casing) Height
Depth
mmmmmm
H max1), (Wmax)1)2)
Max. door width (door width)mm
Weight without/with casing kg
Water content l
Connections Zoll
Switching stage3) 5 4 3 2 1
Air volume m3/h 4000 3450 2980 2620 1660
Electrical power consumption4)
Current consumption4)
Sound pressure level- at a distance of 3m
WA
dB(A)
10914,7760
8733,8156
6582,8752
5672,5149
3051,4440
Heating medium
Entering
air
temp.
tL1 [°C]
Heat outputs
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
LPWW 55/45 °C
14
16
18
20
22
23518
22043
20569
19096
17625
31,0
32,0
33,0
34,0
35,0
21227
19896
18565
17236
15908
31,8
32,8
33,7
34,7
35,6
19147
17946
16746
15547
14349
32,6
33,5
34,4
35,3
36,2
17466
16371
15276
14183
13090
33,3
34,2
35,0
35,9
36,8
12488
11705
10922
10140
9359
35,7
36,5
37,2
38,0
38,7
LPHW 70/55 °C
14
16
18
20
22
31864
30370
28873
27374
25872
37,0
38,1
39,1
40,1
41,1
28759
27411
26060
24707
23352
38,1
39,1
40,1
41,1
42,0
25941
24725
23507
22286
21064
39,2
40,1
41,1
42,0
42,9
23665
22555
21444
20330
19215
40,1
41,0
41,9
42,8
43,7
16920
16126
15332
14536
13738
43,5
44,2
45,0
45,8
46,5
LPHW 70/60 °C
14
16
18
20
22
34591
33115
31639
30162
28685
39,0
40,1
41,1
42,2
43,2
31221
29889
28556
27223
25890
40,2
41,2
42,2
43,2
44,2
28162
26960
25758
24556
23353
41,3
42,3
43,3
44,2
45,2
25690
24594
23497
22401
21304
42,3
43,3
44,2
45,1
46,1
18368
17584
16800
16016
15232
46,0
46,8
47,6
48,4
49,1
LPHW 75/65 °C
14
16
18
20
22
38276
36803
35328
33853
32377
41,7
42,7
43,8
44,9
45,9
34548
33218
31887
30555
29223
42,9
44,0
45,0
46,0
47,1
31162
29963
28762
27561
26359
44,2
45,2
46,2
47,2
48,2
28427
27333
26238
25142
24046
45,4
46,3
47,3
48,2
49,2
20325
19542
18759
17976
17192
49,4
50,2
51,0
51,8
52,6
LPHW 82/71 °C
14
16
18
20
22
43056
41587
40117
38645
37171
45,1
46,2
47,3
48,4
49,5
38861
37535
36208
34880
33550
46,6
47,6
48,7
49,7
50,8
35053
33857
32660
31462
30263
48,0
49,0
50,0
51,1
52,0
31977
30886
29794
28701
27607
49,3
50,3
51,3
52,2
53,2
22863
22083
21302
20520
19738
53,8
54,7
55,5
56,4
57,2
LPHW 90/70 °C 20 39595 49,1 35737 50,5 32236 51,8 29406 53,0 21025 57,3
horizontal
125330125800125810
2500260650
2.3 - 3.02.5
87/134
3.53/4“
vertical
125331125801125811
2500650260
2.3 - 3.02.5.
87/134
3.53/4“
standing
125332125802
---
6502500260
(2.3 - 3.0)(2.5)
87/134
3,5
1“
20
Article no. for DataNorm/EDV entry: 151 000 _ _ _ _ _ _(Insert type)
Tech
nica
l dat
aU
nter
flur
Wan
d-/N
isch
e
1)H max. = max. discharge height, Wmax. = max. discharge width, with average to good pressure conditions/requirements, see p 16 and 172)If the max. discharge width (wide doorway) is exceeded, we would recommend positioning a unit on either side of the door..3)With 3-stage switches, any 3 of the 5 stages can be selected4)For measuring values, see information on p 10
-
34
1.51 Vario Door air curtainsTechnical data
Heat outputs for model size 30 • standing
Vario Door air curtain 30 standing
Basic unit
Basic unit casing
Type
Type
130332
130802
Dimensions Length(incl. casing) Height
Depth
mmmmmm
6503000260
Max. discharge width Wmax)1)2)
Max. door heightmm
2.3 - 3.03.0
Weight without/with casing kg 100/166
Water content l 3.6
Connections Zoll 1“
Switching stage3) 5 4 3 2 1
Air volume m3/h 4260 3760 3220 2800 1860
Electrical power consumption4)
Current consumption4)
Sound pressure level- at a distance of 3m
WA
dB(A)
10914,7761
8733,8157
6582,8754
5672,5150
3051,4441
Heating medium
Luftein-
tritts-
temp.
tL1 [°C]
Heat outputs
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
LPWW 55/45 °C
14
16
18
20
22
24120
22608
21096
19586
18077
30,4
31,4
32,5
33,5
34,6
22147
20758
19370
17983
16598
31,0
32,0
33,1
34,1
35,1
19882
18636
17390
16145
14901
31,8
32,8
33,8
34,7
35,7
18015
16885
15756
14628
13501
32,6
33,5
34,5
35,4
36,3
13384
12545
11706
10868
10031
34,8
35,6
36,4
37,2
38,0
LPHW 70/55 °C
14
16
18
20
22
32680
31148
29613
28075
26535
36,2
37,3
38,3
39,4
40,4
30007
28600
27191
25779
24364
37,1
38,1
39,1
40,2
41,2
26938
25675
24410
23143
21873
38,2
39,2
40,2
41,1
42,1
24408
23264
22117
20969
19819
39,2
40,2
41,1
42,0
42,9
18134
17284
16432
15579
14724
42,2
43,0
43,8
44,6
45,4
LPHW 70/60 °C
14
16
18
20
22
35477
33963
32449
30934
29420
38,1
39,2
40,3
41,4
42,4
32575
31185
29795
28404
27013
39,0
40,1
41,2
42,2
43,3
29244
27996
26748
25499
24251
40,2
41,3
42,3
43,3
44,3
26497
25367
24236
23104
21973
41,4
42,3
43,3
44,3
45,2
19686
18846
18006
17165
16325
44,6
45,5
46,3
47,1
48,0
LPHW 75/65 °C
14
16
18
20
22
39257
37746
36233
34720
33206
40,6
41,8
42,9
44,0
45,1
36046
34658
33269
31880
30490
41,7
42,8
43,9
44,9
46,0
32360
31114
29867
28620
27372
43,0
44,1
45,1
46,1
47,1
29320
28192
27062
25932
24801
44,3
45,3
46,3
47,2
48,2
21783
20945
20106
19266
18426
47,8
48,7
49,6
50,5
51,3
LPHW 82/71 °C
14
16
18
20
22
44158
42652
41144
39634
38123
44,0
45,1
46,2
47,4
48,5
40546
39163
37779
36392
35005
45,2
46,3
47,4
48,5
49,5
36400
35158
33915
32671
31425
46,7
47,7
48,8
49,8
50,9
32981
31856
30730
29603
28474
48,0
49,1
50,1
51,1
52,1
24503
23667
22831
21993
21155
52,1
53,0
53,9
54,8
55,6
LPHW 90/70 °C 20 40609 48,0 37287 49,2 33474 50,6 30330 51,9 22534 55,6
20
Article no. for DataNorm/EDV entry: 151 000 _ _ _ _ _ _(Insert type)
Tech
nica
l dat
a
1)H max. = max. discharge height, Wmax. = max. discharge width, with average to good pressure conditions/requirements, see p 16 and 172)If the max. discharge width (wide doorway) is exceeded, we would recommend positioning a unit on either side of the door..3)With 3-stage switches, any 3 of the 5 stages can be selected4)For measuring values, see information on p 10
-
35
1.51 Vario Door air curtainsTechnical data
Heat outputs for model size 35 • standing
Door air curtains 35 standing
Basic unit
Basic unit casing
Type
Type
135332
135802
Dimensions Length(incl. casing) Height
Depth
mmmmmm
6503500260
Max. discharge width Wmax)1)2)
Max. door heightmm
2,3 - 3,03,5
Weight without/with casing kg 118/189
Water content l 4,4
Connections inch 1“
Switching stage3) 5 4 3 2 1
Air volume m3/h 4950 4360 3750 3250 2140
Electrical power consumption4)
Current consumption4)
Sound pressure level- at a distance of 3m
WA
dB(A)
13275,7562
10544,5858
8003,4855
6913,0551
3791,7942
Heating medium
Entering
air
temp.
tL1 [°C]
Heat outputs
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
Q
[W]
tL2[°C]
LPWW 55/45 °C
14
16
18
20
22
28871
27061
25251
23443
21637
30,9
31,9
32,9
33,9
34,9
26445
24787
23130
21474
19819
31,5
32,5
33,5
34,5
35,4
23796
22304
20813
19323
17834
32,3
33,3
34,2
35,2
36,1
21487
20139
18792
17447
16103
33,1
34,0
34,9
35,8
36,7
15815
14823
13832
12842
11852
35,4
36,1
36,9
37,6
38,4
LPHW 70/55 °C
14
16
18
20
22
39117
37283
35446
33605
31762
36,8
37,9
38,9
40,0
41,0
35830
34150
32467
30782
29093
37,8
38,8
39,8
40,8
41,7
32241
30730
29215
27698
26179
38,8
39,8
40,8
41,7
42,7
29111
27747
26379
25010
23638
39,9
40,8
41,7
42,6
43,5
21427
20423
19416
18408
17398
42,9
43,7
44,5
45,3
46,1
LPHW 70/60 °C
14
16
18
20
22
42465
40653
38840
37028
35215
38,8
39,9
40,9
42,0
43,0
38897
37237
35577
33916
32256
39,8
40,8
41,9
42,9
43,9
35000
33507
32013
30519
29025
41,0
42,0
43,0
43,9
44,9
31603
30255
28906
27557
26207
42,1
43,1
44,0
44,9
45,9
23261
22269
21276
20283
19290
45,4
46,2
47,1
47,9
48,7
LPHW 75/65 °C
14
16
18
20
22
46989
45180
43370
41559
39747
41,4
42,5
43,6
44,7
45,8
43041
41384
39726
38067
36407
42,5
43,6
44,6
45,7
46,7
38730
37239
35747
34254
32760
43,8
44,9
45,9
46,9
47,8
34970
33624
32277
30929
29580
45,1
46,1
47,0
48,0
48,9
25740
24749
23757
22765
21772
48,8
49,6
50,5
51,3
52,1
LPHW 82/71 °C
14
16
18
20
22
52856
51053
49248
47441
45633
44,9
46,0
47,1
48,2
49,3
48415
46764
45110
43455
41799
46,1
47,2
48,3
49,3
50,4
43566
42080
40592
39102
37612
47,6
48,6
49,7
50,7
51,7
39337
37995
36652
35307
33961
49,0
50,0
51,0
52,0
52,9
28953
27966
26977
25987
24997
53,1
54,0
54,9
55,7
56,6
LPHW 90/70 °C 20 48608 48,9 44523 50,0 40064 51,4 36175 52,7 26626 56,6
20
Article no. for DataNorm/EDV entry: 151 000 _ _ _ _ _ _(Insert type)
Tech
nisc
he D
aten
Unt
erfl
ur
W
and-
/Nis
che
1)H max. = max. discharge height, Wmax. = max. discharge width, with average to good pressure conditions/requirements, see p 16 and 172)If the max. discharge width (wide doorway) is exceeded, we would recommend positioning a unit on either side of the door..3)With 3-stage switches, any 3 of the 5 stages can be selected4)For measuring values, see information on p 10
-
36
Vario Door air curtain for cold stores Model 10, horizontal Model 15, horizontal
Basic unitBasic unit casingCasing extension
TypeTypeType
110335110800110810
115335115800115810
Dimensions Length(incl. casing) Height
Depth
mmmmmm
1000260650
1500260650
Max. discharge height Hmax1)
Max. door widthmm
2.3 - 3.01.0
2.3 - 3.01.5
Weight without/with casing kg 30/52 46/79
Switching stage2) 5 4 3 2 1 5 4 3 2 1
Air volume, total m3/h 1390 1220 1050 920 600 2130 1880 1610 1400 930
Electrical power consumption3)
Current consumption3)
Sound pressure level- at a distance of 3m
WA
dB(A)
3921,6857
3131,3554
2381,0550
2020,9147
1130,5436
5732,4858
4561,9855
3461,5151
2981,3248
1640,7837
Vario Door air curtain for cold stores Model 20, horizontal Model 25, horizontal
Basic unitBasic unit casingCasing extension
TypeTypeType
120335120800120810
125335125800125810
Dimensions Length(incl. casing) Height
Depth
mmmmmm
2000260650
2500260650
Max. discharge height H max1)
Max. door widthmm
2.3 - 3.02.0
2.3 - 3.02.5
Weight without/with casing kg 62/100 75/126
Switching stage2) 5 4 3 2 1 5 4 3 2 1
Air volume, total m3/h 2820 2480 2140 1850 1210 4000 3450 2980 2620 1660
Electrical power consumption3)
Current consumption3)
Sound pressure level- at a distance of 3m
WA
dB(A)
7543,275