K820V4 January 2016 T8 Batten Range...January 2016 T8 Batten Range 20mm Title Crompack 5 -...
Transcript of K820V4 January 2016 T8 Batten Range...January 2016 T8 Batten Range 20mm Title Crompack 5 -...
Safe Operation
1. Check the rating label for voltage and frequency before connecting this luminaire to the electrical supply.2. Ensure that the supply is switched off when working on this luminaire, whether installing, re-lamping or carrying out any other servicing.3. Use the correct lamps as initially supplied or as indicated on the ballast label.4. This luminaire is suitable for direct mounting on all non-combustible and normally flammable materials, e.g. timber, plasterboard. Do not mount luminaire on or close to readily flammable materials.5. To prevent damage to H.F. Ballasts do not mix H.F. and Conventional Magnetic Ballasts (Switch, Quick or S.R Start) on the same electrical circuit.6. Where use in more onerous situations is required, e.g. In part-completed buildings before “drying-out” is completed, or areas where ambient temperatures are outside the normal temperature range, then consult our Sales Office. Servicing and Disposal
1. At commissioning and handing over of installation ensure that a copy of these instructions are presented to the authority responsible for the operation and maintenance of the luminaire.2. Servicing, e.g. cleaning, lamp replacement, must only be carried out after the electricity supply has been switched off. It must not be assumed that luminaires with lamps not lit are switched off - always check before servicing.3. Cleaning should be carried out at regular intervals to ensure that dirt does not accumulate to an extent that will impair the thermal safety or optical performance of the luminaire is maintained.4. Failed lamps and starter switches must be replaced as soon as practicable by lamps and starters of the same type. For electronic start circuits allow one minute for the thermal cut-out to re-set before switching on the mains supply.5. At the end of life the lamp and luminaire are classed as WEEE under directive 2002/96/EC and should be disposed of in accordance with local legislation.
Diffuser/controller attachmentsComplete diffuser/controller assembly by firmly pressing home endplates onto diffuser.
Metal reflector, with wireguard attachments
Single lamp fit support brackets tochannel cover fixing screws. Fit diffuserto support brackets.
Twin lamp fit support brackets to channel cover fixing screws. Fit diffuserensuring that diffuser edge engages inanti-lift notches.
Remove protective film from specularinsert. Fit reflector housing to channelcover fixing screws and insert lamp(s).Lift and tilt panel or louvre into positionas shown.
Fix support straps inside reflector usingthe 4mm dia holes provided. Attachreflector to luminaire and insert lamps.
Centralise guard longitudinally, hookone side into support straps and tightenscrews to retain. Swing other side of guard and locate in support straphooks. Tighten screws to retain.
Fit wireguard bracket assembly tochannel cover fixing screws andslacken clamp bracket screws. Hookone side of wireguard onto bracket andcentralise longitudinually. Swing up other side into position and tightenscrews to retain.
Unscrew and remove geartray
cover
Fixing Details
These luminaires comply with BSEN60598-1 and are suitable for use in normal indoors conditions.o oApproved normal ambient temperature range: 5 C to 25 C.
Installation notes
a) Ballasts comply with BS2818 but the surface temperature of ballast castings may damage standard insulation o cables. Where supply cables run adjacent to ballast casings, use cable rated at not less than 150 C (BS6500,
type E12) or alternatively protect standard insulation cables with heat resistant sleeving.b) When 20mm conduit bush fixing is used, place an adequately sized steel washer between inside of channel and bush. When small head fixing screws are used fit washers or slip-fix platese.c) 20mm knockouts are provided in channel endplates. For surface conduit end entry fit hexagonal male bush from inside of luminaire channel.d) Mounting in-line. For use with diffusers/controllers space battens at least 15mm apart. For bare battens (or with reflectors) may butt up together.e) On luminaires where gear is mounted on a seperate geartray, access to the besa entry and fixing points can be gained by removing the geartray.
Hold channel tofixing surface and screw to secure
(525mm on 600mm/2ft Battens)
CL
600mm
Connect supply to3-way terminal,block marked,
L, N and E
Wiring Details
NOTE: Ensure lampholders with yellow wires are holding
the same lamp
LUMINAIRES MUST BE EARTHED
N
L
- Blue- Green/Yellow- Brown
Place geartray cover back into position and
screw to lock into place
Insert lamp/s
o90
Slide lampholders into position, ensuring they are registered against the back stop in the
endcap
Single
Twin
6 7 8
9 10 11
1 2 3
4 5
Instruction Leaflet K820V4
T8 Batten RangeJanuary 2016
K820V4
Eaton Wheatley Hall Road, Doncaster, South Yorkshire, DN2 4NBSales T: +44 (0)1302 303303 F: +44 (0)1302 367155 E: [email protected]
General +44 (0)1302 321541+44 (0)1302 [email protected]
International Sales +44 (0)1302 303250+44 (0)1302 [email protected]
Instruction Manual - K820V4January 2016
T8 Batten Range
20mm