Chapter 7: High Availability
Junos Enterprise Switching
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-2Worldwide Education Services
Chapter Objectives
After successfully completing this chapter, you will be
able to:
•List and describe features that promote high availability
•Configure and monitor high availability features
•Describe key concepts and components of a Virtual Chassis
•Explain the operational details of a Virtual Chassis
•Implement a Virtual Chassis and verify its operations
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-3Worldwide Education Services
Agenda: High Availability
Overview of High Availability Networks
Link Aggregation Groups
Redundant Trunk Groups
Virtual Chassis
•Overview of Virtual Chassis
•Configuring and Monitoring a Virtual Chassis
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-4Worldwide Education Services
What Is High Availability?
The ability to ensure a high degree of operational
continuity to a resource for a user community
•Typically measured over a specific period of time
User Community
Resources
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-6Worldwide Education Services
High Availability Networks
High availability networks include provisions that allow
for the maximum amount of uptime and accessibility
Increase uptime and accessibility
Decrease downtime
Key Considerations
1. Is the base functionality of the network’s hardware,
software, protocols, and overall operations protected?
2. When a failure occurs, how will the overall system or
network react and what level of recovery can be expected?
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-7Worldwide Education Services
High Availability Features
EX Series switches support a number of features to
help increase uptime and availability including:
•Link aggregation groups (LAGs)
•Redundant Trunk Groups (RTG)
•Virtual Chassis
Note: Feature support varies by product; check the product-specific documentation for support details.
User Community
Resources
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-8Worldwide Education Services
Agenda: High Availability
Overview of High Availability Networks
Link Aggregation Groups
Redundant Trunk Groups
Virtual Chassis
•Overview of Virtual Chassis
•Configuring and Monitoring a Virtual Chassis
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-9Worldwide Education Services
Link aggregation combines multiple Ethernet interfaces in to a single link layer interface, also known as a link aggregation group (LAG) or bundle
•Defined in the 802.3ad standard
What Is It?
Access
Aggregation
ge-0/0/12
ge-0/0/13
Switch-1 Switch-2
Participating interfaces are
known as member linksCommonly used on
trunk port connections
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-10Worldwide Education Services
Benefits of 802.3ad Link Aggregation
Benefits of 802.3ad link aggregation include:
•Increases bandwidth
•Provides link efficiency
•Creates physical layer redundancy
Access
Aggregation
ge-0/0/12
ge-0/0/13
Switch-1 Switch-2
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-11Worldwide Education Services
Link Requirements and Considerations
Interface requirements and considerations include:
•Duplex and speed must match
•Up to eight member links per LAG
•Member links do not need to be contiguous ports nor must
they be on the same switch when part of a Virtual Chassis
ge-0/0/13
ae0
ge-0/0/1
Switch-1 Switch-2
ae0
………
ge-0/0/5
ge-0/0/10……
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-12Worldwide Education Services
Traffic processing and forwarding considerations:
•RE generated traffic is always sent on the lowest member
link
•IP traffic hashing uses Layer 2, Layer 3, and Layer 4 details
•Non-IP traffic hashing uses source and destination MAC
addresses
Traffic Processing and Forwarding
ge-0/0/13
ae0
ge-0/0/1
Switch-1 Switch-2
ae0
IP traffic
Non-IP traffic
RE traffic
Traffic is shared across
all member links
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-13Worldwide Education Services
Link Aggregation Control Protocol
LACP performs link monitoring and controls the
member links that form a single logical channel
You can set the LACP mode as active or passive:
•Active mode initiates transmission of LACP packets
•Passive mode responds to LACP packets
Access
Aggregation
Switch-1 Switch-2
ae0
ae0
ae1 ae1
Passive
Active Active
Note: At least one device must be configured for
active mode for the link to become operational.
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-14Worldwide Education Services
Implementing LAGs (1 of 2)
{master:0}[edit chassis]
user@Switch-1# run show interfaces terse | match ae0
{master:0}[edit chassis]
user@Switch-1# set aggregated-devices ethernet device-count 1
{master:0}[edit chassis]
user@Switch-1# commit
configuration check succeedscommit complete
{master:0}[edit chassis]
user@Switch-1# run show interfaces terse | match ae0
ae0 up down
Switch-1 Switch-2
ae0 ae0
ge-0/0/12
ge-0/0/13
Create an aggregated Ethernet interface:
Link state remains down until operational
member links are added to LAG
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-15Worldwide Education Services
Configure the aggregated Ethernet interface and
associate desired member links with the LAG:
Implementing LAGs (2 of 2)
{master:0}[edit interfaces]
user@Switch-1# set ae0 unit 0 family ethernet-switching
{master:0}[edit interfaces]
user@Switch-1# set ae0 aggregated-ether-options lacp active
{master:0}[edit interfaces]
user@Switch-1# set ge-0/0/12 ether-options 802.3ad ae0
{master:0}[edit interfaces]
user@Switch-1# set ge-0/0/13 ether-options 802.3ad ae0
{master:0}[edit interfaces]
user@Switch-1# commit
configuration check succeedscommit complete
{master:0}[edit interfaces]
user@Switch-1# run show interfaces terse | match ae0
ge-0/0/12.0 up up aenet --> ae0.0
ge-0/0/13.0 up up aenet --> ae0.0
ae0 up up
ae0.0 up up eth-switch
ae0
Switch-1 Switch-2
ae0
ge-0/0/12
ge-0/0/13
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-16Worldwide Education Services
Monitoring LAGs
Use the show interfaces output to determine
state information for aggregated interfaces:
•Note that other commands exist that show similar details
{master:0}
user@Switch-1> show interfaces terse | match ae0
ge-0/0/12.0 up up aenet --> ae0.0
ge-0/0/13.0 up up aenet --> ae0.0
ae0 up up
ae0.0 up up eth-switch
{master:0}
user@Switch-1> show interfaces extensive ae0.0 | find "LACP Statistics:"
LACP Statistics: LACP Rx LACP Tx Unknown Rx Illegal Rx
ge-0/0/12.0 26 516 0 0
ge-0/0/13.0 25 519 0 0
Marker Statistics: Marker Rx Resp Tx Unknown Rx Illegal Rx
ge-0/0/12.0 0 0 0 0
ge-0/0/13.0 0 0 0 0
Protocol eth-switch, Generation: 195, Route table: 0
Flags: None
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-17Worldwide Education Services
Test Your Knowledge
Given the sample outputs, can you guess what might
be causing ae0.0 to remain in the down state?{master:0}
lab@Switch-1> show interfaces terse | match ae0
ge-0/0/12.0 up up aenet --> ae0.0
ge-0/0/13.0 up up aenet --> ae0.0
ae0 up down
ae0.0 up down eth-switch
{master:0}
lab@Switch-1> show interfaces extensive ae0.0 | find "LACP Statistics:"
LACP Statistics: LACP Rx LACP Tx Unknown Rx Illegal Rx
ge-0/0/12.0 0 224 0 0
ge-0/0/13.0 0 223 0 0
Marker Statistics: Marker Rx Resp Tx Unknown Rx Illegal Rx
ge-0/0/12.0 0 0 0 0
ge-0/0/13.0 0 0 0 0
Protocol eth-switch, Generation: 195, Route table: 0
Flags: None
•The remote device does not have LACP enabled
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-18Worldwide Education Services
Agenda: High Availability
Overview of High Availability Networks
Link Aggregation Groups
Redundant Trunk Groups
Virtual Chassis
•Overview of Virtual Chassis
•Configuring and Monitoring a Virtual Chassis
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-19Worldwide Education Services
What Is It?
A redundant trunk group provides a quick and simple
failover mechanism for redundant Layer 2 links
•Can be used as a replacement for STP on access switches
that are connected to two aggregation switches
Access
Aggregation
ge-0/0/1
ge-0/0/2
Switch-1 Switch-2
Switch-3 Switch-4 Switch-5
RSTP
RTG
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-20Worldwide Education Services
Only active link is used to forward traffic, other links
serve as backup links and do not forward traffic
•When active link fails, a backup link becomes active
Backup Link
How Does It Work?
Access
Aggregation
ge-0/0/1
ge-0/0/2
Switch-1 Switch-2
Switch-3
RSTP
RTG
Active Link
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-21Worldwide Education Services
Configuration Considerations
RTG is typically only configured on access switches
•RTG and STP are mutually exclusive on a given port
•STP BPDUs received on RTG links are discarded
•STP is configured on aggregation switches
Access
Aggregation
ge-0/0/1
ge-0/0/2
Switch-1 Switch-2
Switch-3 Switch-4 Switch-5
RSTP
RTG
Note: A maximum of 16 redundant trunk groups per switch.
ge-0/0/8ge-0/0/10
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-22Worldwide Education Services
Case Study: Topology and Objectives
Access
Aggregation
Switch-1 Switch-2
Switch-3
Objectives:
•Implement RTG on Switch-3 to ensure that only a single path
is available toward the aggregation switches
•Ensure that Switch-3 forwards user traffic out ae0.0
whenever it is operational
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-23Worldwide Education Services
Case Study: Configuring RTG
{master:0}[edit ethernet-switching-options]
user@Switch-3# set redundant-trunk-group group rtg-1 interface ae0.0 primary
{master:0}[edit ethernet-switching-options]
user@Switch-3# set redundant-trunk-group group rtg-1 interface ge-0/0/10.0
{master:0}[edit ethernet-switching-options]
user@Switch-3# show
redundant-trunk-group {
group rtg-1 {
interface ge-0/0/10.0;
interface ae0.0 {
primary;
}
}
}
You configure RTG under the [edit ethernet-
switching-options] hierarchy:
Access
Aggregation
Switch-1 Switch-2
Switch-3
Note: If primary knob is omitted, highest-numbered interface initially becomes active link but does not
preempt lower-numbered interfaces functioning as the active link in failure and recovery scenarios
Interface marked as primary is
always active when operational
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-24Worldwide Education Services
Case Study: Monitoring RTG
{master:0}
user@Switch-3> show redundant-trunk-group
Group Interface State Time of last flap Flap
name count
rtg-1 ae0.0 Up/Pri/Act Never 0
ge-0/0/10.0 Up Never 0
Use show redundant-trunk-group to monitor
RTG operations:
Access
Aggregation
Switch-1 Switch-2
Switch-3
(Pri) = Primary interface with preemption enabled
(Act) = Active interface currently forwarding traffic
ae0.0 is selected as the primary
interface for the rtg-1 RTG group
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-25Worldwide Education Services
Lab 6: Implementing LAGs and RTG
Configure and monitor LAGs and RTG.
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-26Worldwide Education Services
Agenda: High Availability
Overview of High Availability Networks
Link Aggregation Groups
Redundant Trunk Groups
Virtual Chassis
Overview of Virtual Chassis
•Configuring and Monitoring a Virtual Chassis
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-27Worldwide Education Services
What Is It?
Two or more interconnected EX Series switches
operating as a single Virtual Chassis system
Valid chassis combinations
•Two or more (up to 10) EX4200s
•Two EX4500s
•Two EX4500s with up to eight EX4200s
•Two EX8200s including an external
routing engine
10 RU JunosUp to 10 switches can
be interconnected
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-29Worldwide Education Services
Benefits of Virtual Chassis
Virtual Chassis benefits include:
•High availability: Redundant REs
• Enables the use of NSR
•Simplified network design: Single network entity to manage,
configure, and monitor; potential elimination of STP; flexible
placement of member switches
Junos
RE 0
RE 1
LC
LC
LC
LC
LC
LC
LC
LC
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-31Worldwide Education Services
Virtual Chassis Components
Virtual Chassis components include:
•EX Series switches
• Participating switches serve as REs or line cards (LCs)
•Virtual Chassis ports (can be dedicated VCPs or uplink ports
converted to extended VCPs through configuration)
• VCPs interconnect PFEs from one switch to another to form a
single backplane
RE 0
Location 1 Location 2
Gigabit Ethernet or 10 GbE extended VCPs
(must be enabled through configuration)
Gigabit Ethernet or 10 GbE extended VCPs
Dedicated VCPs
(enabled by default)
LC
LC
LCLC
LC
LC
RE 1
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-32Worldwide Education Services
Virtual Chassis Cabling Options (1 of 3)
Dedicated Virtual Chassis daisy-chained ring method
•Longest cable spans the entire Virtual Chassis; maximum
length between end systems is 5 meters
Note: The EX4200 Series switches come with a .5 meter cable.
You can acquire longer cables in lengths of 1, 3, and 5 meters.
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-33Worldwide Education Services
Virtual Chassis Cabling Options (2 of 3)
Dedicated Virtual Chassis braided ring method
•Maximum length between end devices in a Virtual Chassis
consisting of 10 EX Series switch is 22.5 meters
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-34Worldwide Education Services
Virtual Chassis Cabling Options (3 of 3)
Extended Virtual Chassis ring method
•Maximum circumference of ring using is 100 km; uses 1 GbE
or 10 GbE uplinks to extend the distance of the Virtual Chassis
Virtual Chassis Location 1 Virtual Chassis Location 2
GbE or 10 GbE uplink ports
GbE or 10 GbE uplink ports
Up to 100 km
This option is required when the circumference of a Virtual Chassis exceeds 22.5 meters.
This option is often used to interconnect wiring closets or data center racks or rows.
Dedicated Virtual
Chassis ports
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-35Worldwide Education Services
RE placement recommendations:
•Ensure spatial redundancy and avoid split Virtual Chassis
issues and other failure conditions by evenly spacing the
master and backup REs (by hop) and by separating REs
from uplinks
Recommended RE Placement (1 of 2)
Uplink
Uplink
Dedicated Virtual Chassis daisy-chained ring Dedicated Virtual Chassis braided ring
RE 0
Uplink
Uplink
RE 1
RE 0
RE 1
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-36Worldwide Education Services
RE placement recommendations (contd.):
•When implementing an extended Virtual Chassis, you should
place the master and backup REs in different locations
Recommended RE Placement (2 of 2)
Extended Virtual Chassis ring
RE 0
Location 1 Location 2
Gigabit Ethernet or 10 GbE extended VCPs
Gigabit Ethernet or 10 GbE extended VCPs
Dedicated VCPs
RE 1
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-37Worldwide Education Services
Master and Backup Election
Mastership determination:1. Member with the highest user-configured priority
• Priority range is 1–255, factory-default value is 128
2. Member previously functioning as master prior to reboot
3. Member with the longest standing uptime• Difference must be greater than 1 minute
4. Member with the lowest MAC address• Used as tie breaker if all is equal through the first three
determination steps
5. Second member in election decision tree becomes backup
switch; all other members are line cards
Note: If a master or backup fails, one of the line card switches
is elected the new backup switch using the same criteria.
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-38Worldwide Education Services
Member ID and Interface Names
All member switches are assigned a member ID (0–9)
•Member ID is assigned manually through configuration or
dynamically from the master switch (usually member ID 0)
•Member ID is preserved through reboots
•Member ID serves as slot number for interface naming
RE 0
RE 1
LC
LC
Member ID: 0
Member ID: 1
Member ID: 2
Member ID: 3
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-40Worldwide Education Services
Replacing a Member Switch
When a member switch is removed, its member ID is
not automatically released and made available nor
will the replacement switch automatically inherit the
configuration associated with the previous switch
•Recommended replacement steps:
1. Recycle the member ID of the switch being replaced so it
becomes the next-lowest available unused member ID
2. Add replacement switch which should automatically be assigned
the recycled member ID and inherit the required configuration
{master:0}
user@Switch-1> request virtual-chassis recycle member-id <member-id>
Note: You recycle member IDs on the master switch.
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-41Worldwide Education Services
Think About It!
Given the member ID assignments, what are the
interface names for the highlighted interfaces?
•Hint: All member switches are 48 port models and all
interfaces are Gigabit Ethernet interfaces
Location #2
Member ID: 0
Member ID: 1
Member ID: 2
Member ID: 3
RE 0
RE 1
LC
LC
ge-3/0/46 and ge-3/0/47ge-1/0/0 and ge-1/0/1
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-42Worldwide Education Services
{master:0}[edit]
user@Switch-1# show interfaces vme
unit 0 {
family inet {
address 10.210.14.148/27;
}
}
{master:0}[edit]
user@Switch-1# run show interfaces terse vme
Interface Admin Link Proto Local Remote
vme up up
vme.0 up up inet 10.210.14.148/27
Management Connectivity (1 of 2)
Single management interface and IP address
•Individual management Ethernet ports (me0) on member
switches are tied to a special management VLAN associated
with a Layer 3 virtual management Ethernet (VME) interface
•The Virtual Chassis system is managed as a single network
element; therefore, it has only one management IP address
RE 0
RE 1
LC
LC
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-43Worldwide Education Services
Management Connectivity (2 of 2)
Single virtual console
•Connection to a console on any member switch in a Virtual
Chassis system is redirected to the master switch by the
virtual console software running on all member switches
RE 0
RE 1
LC
LC
Console ports
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-44Worldwide Education Services
Software Upgrades
You can perform software upgrades for a single Virtual Chassis member or for all members from the master switch
Master switch performs a software compatibility check for each member added to the Virtual Chassis
•If a version mismatch exists, a syslog message is generated and the newly added switch is placed in an inactive state
•Upgrade incompatible switches from the master switch manually or enable the automatic software upgrade option
{master:0}
user@Switch-1> request system software add member ?
Possible completions:
<member> Install package on VC Member (0..9)
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-45Worldwide Education Services
Topology Discovery (1 of 3)
Virtual Chassis members use VCCP to create a loop-
free topology
•LSA-based discovery messages are exchanged between all
PFEs and build the member switch and PFE topology maps
•Each switch runs the shortest-path first (SPF) algorithm for
each PFE which creates PFE map tables between all PFEs
•Each PFE builds source ID egress filter tables used to
prevent broadcast and multicast packets from looping
b ca e fd h ig
Switch-1 Switch-2 Switch-3
Virtual Chassis cables and backplane
VCCP LSA-based messages
PFEs
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-46Worldwide Education Services
Topology Discovery (2 of 3)
Topology discovery example:
b ca e fd h ig
Physical Virtual Chassis Cabling
a
i
b
h
d
f
e
c
g
Virtual Chassis Backplane
Logical Virtual Chassis Ring Topology
Note: a, b, c, … i are PFEs
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-47Worldwide Education Services
Topology Discovery (3 of 3)
Topology discovery example (contd.):
a
i
b
h
d
f
e
c
g
Logical Virtual Chassis Ring Topology
Virtual Chassis Backplane
Note: a, b, c, … i are PFEs
a
b
i
c
h
d
g
e
f
PFE a’s Rooted Reachability SPF Tree
g
f
h
e
i
d
a
c
b
PFE g’s Rooted Reachability SPF Tree
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-48Worldwide Education Services
Inter-Chassis Packet Flow
Packets always take the shortest path through a Virtual Chassis
•Shortest path is determined by hop count and bandwidth
•Inter-chassis packet flow examples:
1. Packets going from ge-0/0/10 to ge-3/0/14 pass through member 4 because it is a shorter path
2. Packets going from ge-0/0/28 to ge-2/0/47 pass through member 1 because it is a shorter path
0
1
2
3
4
ge-0/0/10
ge-3/0/14
ge-0/0/28
ge-2/0/47
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-49Worldwide Education Services
Agenda: High Availability
Overview of High Availability Networks
Link Aggregation Groups
Redundant Trunk Groups
Virtual Chassis
•Overview of Virtual Chassis
Configuring and Monitoring a Virtual Chassis
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-50Worldwide Education Services
Virtual Chassis Configuration
You enable Virtual Chassis configuration options under
the [edit virtual-chassis] hierarchy:{master:0}[edit virtual-chassis]
user@Switch-1# set ?
Possible completions:
+ apply-groups Groups from which to inherit configuration data
+ apply-groups-except Don't inherit configuration data from these groups
> auto-sw-update Auto software update
> fast-failover Fast failover mechanism
id Virtual Chassis identifier, of type ISO system-id
> mac-persistence-timer How long to retain MAC address when member leaves Virtual Chassis
> member Member of Virtual Chassis configuration
no-split-detection Disable split detection. Only recommended in a 2 member setup
preprovisioned Only accept preprovisioned members
> traceoptions Global tracing options for Virtual Chassis
{master:0}[edit chassis]
user@Switch-1# set redundancy graceful-switchover?
Possible completions:
> graceful-switchover Enable graceful switchover on supported hardware
•To minimize traffic interruption during an RE failover scenario,
enable graceful Routing Engine switchover:
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-52Worldwide Education Services
Dynamic configuration steps:
Dynamic Configuration Process (1 of 2)
1. Install desired master switch:
• Power up desired master switch,
switch becomes master and obtains
member ID 0, assign mastership
priority 255
2. Add desired backup switch:
• Connect to master switch using
Virtual Chassis cable, power up
desired backup switch, switch is
elected as backup and dynamically
assigned member ID 1, assign
mastership priority 255
0
1
2
3
4
Linecard
Backup (Backup RE)
Master (Active RE)
Linecard
Linecard
ON
ON
{master:0}[edit virtual-chassis]
user@Switch-1# set member <member-id> mastership-priority <priority>
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-53Worldwide Education Services
Dynamic configuration steps (contd.):
Dynamic Configuration Process (2 of 2)
3. Add line card switch:
• Connect to switch above with VCB
cable, power up third switch—switch
becomes line card and is dynamically
assigned member ID 2, assign desired
mastership priority
4. Repeat Step 3 to add subsequent
line card switches:
• Last line card switch completes loop
by connecting with master
0
1
2
3
4
Linecard
Backup (Backup RE)
Master (Active RE)
Linecard
Linecard
ON
ON
ON
ON
ON
{master:0}[edit virtual-chassis]
user@Switch-1# set member <member-id> mastership-priority <priority>
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-54Worldwide Education Services
Preprovisioned Configuration Example
{master:0}[edit virtual-chassis]
user@Switch-1# show
preprovisioned;
member 0 {
role routing-engine;
serial-number BM0208105168;
}
member 1 {
role line-card;
serial-number BM0208124111;
}
member 2 {
role routing-engine;
serial-number BM0208124231;
}
member 3 {
role line-card;
serial-number BM0208124333;
}
Member ID: 0
Member ID: 1
Member ID: 2
Member ID: 3
RE 0
RE 1
LC
LC
Note: You should power on the switch designated as RE0 first, create and activate
the desired preprovisioned configuration, and then add the remaining switches.
Note when preprovisioned option is used, you do not specify a
mastership priority but rather only assign the role to a given device.
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-55Worldwide Education Services
Monitoring Virtual Chassis Operations
Use the show virtual-chassis commands to
monitor Virtual Chassis operations:{master:0}
user@Switch-1> show virtual-chassis ?
Possible completions:
<[Enter]> Execute this command
active-topology Virtual Chassis active topology
device-topology PFE device topology
fast-failover Fast failover status
login
protocol Show Virtual Chassis protocol information
status Virtual Chassis information
vc-path Show virtual-chassis packet path
vc-port Virtual Chassis port information
| Pipe through a command
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-56Worldwide Education Services
Verifying Virtual Chassis Port State
Use show virtual-chassis vc-port to view
VCP state and details:{master:0}
user@Switch-1> show virtual-chassis vc-port
fpc0:
--------------------------------------------------------------------------
Interface Type Trunk Status Speed Neighbor
or ID (mbps) ID Interface
PIC / Port
vcp-0 Dedicated 2 Up 32000 1 vcp-0
vcp-1 Dedicated 1 Up 32000 1 vcp-1
fpc1:
--------------------------------------------------------------------------
Interface Type Trunk Status Speed Neighbor
or ID (mbps) ID Interface
PIC / Port
vcp-0 Dedicated 2 Up 32000 0 vcp-0
vcp-1 Dedicated 1 Up 32000 0 vcp-1
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-57Worldwide Education Services
Enabling and Disabling Virtual Chassis
Ports
Built-in VCPs (vcp-0/vcp-1) are enabled by default
•You can disable or re-enable VCPs in operational mode:
{master:0} VC
user@Switch-1> request virtual-chassis vc-port set interface vcp-0 disable
{master:0}
user@Switch-1> show virtual-chassis vc-port
fpc0:
--------------------------------------------------------------------------
Interface Type Trunk Status Speed Neighbor
or ID (mbps) ID Interface
PIC / Port
vcp-0 Dedicated 2 Disabled 32000
vcp-1 Dedicated 1 Up 32000 1 vcp-1
...
{master:0}
user@Switch-1> request virtual-chassis vc-port set interface vcp-0
{master:0}
user@Switch-1> show virtual-chassis vc-port
fpc0:
--------------------------------------------------------------------------
Interface Type Trunk Status Speed Neighbor
or ID (mbps) ID Interface
PIC / Port
vcp-0 Dedicated 2 Down 32000
vcp-1 Dedicated 1 Up 32000 1 vcp-1
...
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-59Worldwide Education Services
Verifying Status Information
Use show virtual-chassis status to view
Virtual Chassis status information:{master:0}
user@Switch-1> show configuration virtual-chassis
preprovisioned;
member 0 {
role routing-engine;
serial-number BM0208105168;
}
member 1 {
role line-card;
serial-number BM0208124231;
}
{master:0}
user@Switch-1> show virtual-chassis status
Preprovisioned Virtual Chassis
Virtual Chassis ID: 8d5c.a77f.8de8
Mastership Neighbor List
Member ID Status Serial No Model priority Role ID Interface
0 (FPC 0) Prsnt BM0208105168 ex4200-24t 129 Master* 1 vcp-0
1 vcp-1
1 (FPC 1) Prsnt BM0208124231 ex4200-24t 0 Linecard 0 vcp-0
0 vcp-1
Member ID: 0
Member ID: 1
RE 0
LC
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-60Worldwide Education Services
Summary
In this chapter, we:
•Listed and described features that promote high availability
•Configured and monitored high availability features
•Described key concepts and components of a Virtual
Chassis
•Explained the operational details of a Virtual Chassis
•Implemented a Virtual Chassis and verified its operations
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-61Worldwide Education Services
Review Questions
1. What is the purpose of LACP?
2. In what situation would you likely find RTG?
3. List some benefits of implementing a Virtual
Chassis.
© 2011 Juniper Networks, Inc. All rights reserved. www.juniper.net | 7-62Worldwide Education Services
Lab 7: Virtual Chassis
Implement and verify operations of a Virtual Chassis.
Worldwide Education Services