JT - JBC Soldering Tools · 2 jt / high-power hot-air control unit jt-sa stand jt-t2a (230v) or...
Transcript of JT - JBC Soldering Tools · 2 jt / high-power hot-air control unit jt-sa stand jt-t2a (230v) or...
JTHIGH-POWER
HOT AIR STATION
www.jbctools.com
2
JT / HIGH-POWER HOT-AIR
CONTROL UNIT JT-SASTAND
JT-T2A (230V) or JT-T1A (100V-120V) HEATING SET
0008748 EXTRACTOR STAND *
JN2015 ø4JN2012 ø6 JN2020 ø8NOZZLE
0930110 SUCTION CUPS *
0932330 SUCTION TUBE *
T2050 ø20T2250 ø40 TRIPOD*
POWER CORD
* These accessories not supplied with JT-2QA / JT-1QA / JT-9QA stations
ProtectorP2220 (32)P2230 (48)P2235 (24)P4000 (44)P4010 (60)
ExtractorE2184E2084E2068E2064E2052
JTHIGH-POWER
HOT AIR STATION
www.jbctools.com
3
INSTALLATION
Power cordsocket
Equipotencialconnection
Pedal 0964551(NOT INCLUDED)(ON / OFF hot air)
DESCRIPTION
Display
Function keys
Connectable tools: JT-T2A / JT-T1A TE-TA
Heating element
Hot Air switch (ON / OFF)
Suction Tube
Main switch
Heater inlet
Vacuum inlet for tripods and extractors
Activation of suction pump
4
CONTROL SCREEN / MANUAL MODE
CONTROL SCREEN / PROFILE MODE
Decrease & move down
Decrease profile number
Increase & move up
Increase profile number
Access Menu&
Confirm Selection
Access Menu(pess key 2 secondes)
Temp ºC
Temp ºC
Air %
ºC
Time to stop 45 seconds
Prof i le 8
Power 70%
400
380
80Selected temperature
Current temperature
% Instant power supplied to heater
Selected profile
Current temperature
Selected flowGraph of selected profile
Remaining time
400ºC Select
Air 100%Time 125s.
You can switch between operating modes (Manual Mode / Profiles Mode) by pressing the “increase” and “decrease” keys simultaneously for 2 seconds. (Only if mode profiles is ON)
PRESS Key 2 seconds
to access Menu
5
SelectProf i le
Step 4Time 20Temp 450Air 100
ºC
ºC
Edit Prof i le
Edit Prof i le 8
8
ORIGINAL PIN: 0105
Main menu
Sett ings
Counters
1 Reset settings2 Station Settings3 Profile Settings4 Counters
5 Program version
1 Temp unit Celsius2 Maximum temp 4500C3 Minimum temp T OFF4 Fix temp 4000C
5 Max air 100%6 Min air 10%7 Fix air 40%8 Time to stop 120 sec9 Beep ON10 Pop up ON11 Change PIN
1 Station ON hours 02 Works hours 03 Works cycles 0
Exit
Back
Back
Exit
SETTINGS
*
* Selecting Tmin to “T OFF” allows for blowing at ambient temperature.
Prof i le sett ings
1 Profiles2 Edit Profile3 Copy profile
Exit
6
DESOLDERING PROCEDURE
1. Position suction cup. 2. Hot-air melts solder. 3. IC pops up automatically.
EDIT PROFILEThis option allows you to edit or create a profile. First , you must select the profile to edit and then modify the points that make up the profile. Each profile is composed of 9 points, each point is formed by three parameters: 1. Time (seconds) 2. Temperature (° C / ° F) 3. Flow rate (%)
You can delete the last point of the profile by selecting “-----” in the time parameter. It should be taken into account that the regulation range permitted by the station is between 150°C and 450°C, whereby it is not possible to create temperature ramps between room temperature (Toff) and 150°C.
The station can store up to 25 temperature profiles.The first three profiles are edited as an example.
COPY PROFILEThis option allows you to copy a profile. You must select the profile source and the destination profile where it will be copied.
DELETE PROFILEThis option will allow you to delete a profile previously selected.
7
MAINTENANCE
CHANGING THE HEATING SET1. Ensure that the tool is off.2. Use a wrench to unscrew the connector seal.
REPLACING THE HEATING ELEMENTOnly perform this operation when element is cold and unit is disconnected from mains.1. Untighten screw.2. Pull element forward off handpiece.3. Connect new heating element, ensuring its seated all the way in.4. Replace screw.
3. Pull back the seal.4. Pull connector from socket to disconnect heating set.5. Follow steps in reverse to connect the heating set.
0011070 (230V) or0007565 (100V-120V)Heating element
0009829 Handle
JT-T2A (230V) orJT-T1A (100V-120V)Heating set
WARRANTY
JBC’s 2 years warranty guarantees this equipment against all manu-facturing defects, covering the replacement of defective parts and all necessary labour.
Warranty does not cover product wear due to use or mis-use.
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased enclosing this fully filled in, sheet.
www.jbctools.com
SERIAL Nº
STAMP OF DEALER
DATE OF PURCHASE
0009
044/
1112
TECHNICAL SPECIFICATIONS
- Temperature selection from room temperature to 450°C (850ºF) and cool mode (can be used to blow air at room temperature).
- Ambient Operating Temperature: 10 to 40ºC (50-104ºF)- Output Peak Power: 1000W.- Air flow regulation: 6-45 l/min.- JT-2A 230V 50/60Hz. Input fuse 4A. - JT-1A 120V 50/60Hz. Input fuse 8A.- JT-9A 100V 50/60Hz. Input fuse 8A.- Total weight of unit: 2.3Kg (5.1lb)- Complies with CE standards on electrical safety, electromagnetic compatibility and ESD protected housing “skin effect”.- RoHS compliant.- Equipotential connector and the tool tip are connected to station mains ground supply for ESD protection.
This product should not bethrown in the garbage.