J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon...
-
Upload
rodger-briggs -
Category
Documents
-
view
215 -
download
0
Transcript of J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon...
![Page 1: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/1.jpg)
Calibración temporal del telescopio de neutr inos ANTARES mediante trazas de muones atmosféricos
J.P. Gómez-González
![Page 2: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/2.jpg)
Outline
• Introduction:• The ANTARES neutrino telescope • Time calibration
• Muon track residuals based method:• Description and implementation• Inter-line calibration• Intra-line calibration
• Cross-check with the OB system • Detector performance
• Summary/Conclusions
1 Calibración temporal en ANTARESBienal de Física 2013
![Page 3: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/3.jpg)
Neutrino astrophysics
1 Calibración temporal en ANTARESBienal de Física 2013
p
γν
n
• Astroparticle physics: Point-like sourcesDiffuse flux, galactic plane neutrino fluxFlaring blazars / microquasarsGRBsFermi Bubbles
• Particle physics:Neutrino oscillationAtmospheric neutrino and muon fluxCosmic ray anisotropy / compositionShower reconstructionElectromagnetic showers
• Detector related:Timing / PositioningMoon shadowWater optical properties, group velocity of lightAcoustics, bioluminescence
• Searches: Dark matter annihilation,magnetic monopoles, nuclearitesMulti-messenger astronomy: Gravitational waves, Auger CRs, optical telescopes
![Page 4: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/4.jpg)
Detection principle
1 Calibración temporal en ANTARESBienal de Física 2013
m
42°
interaction
Earth’s crust
Cherenkov light
from m
nm
Detection principle
“We propose getting up an apparatus in anunderground lake or deep in the oceanin order to determine the location of charged particles with the help of Cherenkov radiation” M. Markov, 1960
Detector:3D array of
photomultipliers
At high energies the neutrino and the muon are almost collinear Astronomy
![Page 5: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/5.jpg)
Physical background
1 Calibración temporal en ANTARESBienal de Física 2013
nm
p
nm
nm
mp, a
• Huge (downgoing) atmospheric muon contamination• Irreducible contribution from atmospheric neutrinos
Downgoing muon flux is about 6 orders of magnitude higher than neutrino flux
![Page 6: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/6.jpg)
The ANTARES detectorANTARES is a submarine neutrino telescope made up by:
1 Calibración temporal en ANTARESBienal de Física 2013
885 10” PMTs distributed in triplets of storeys along 12 strings of 450 meters longitude placed 2475 depth following an octagonal layout.
![Page 7: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/7.jpg)
Muon track reconstructionTime and position information of the hits registered by the PMTs is used for track reconstruction Offline strategy based on the time residual; difference between the measured hit time and the time expected from the fitted muon (given a certain set of track parameters)
1 Calibración temporal en ANTARESBienal de Física 2013
![Page 8: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/8.jpg)
Time residualsThe reconstruction algorithm is a multi-step approach which final step consists on the minimization of the time residuals PDF
1 Calibración temporal en ANTARESBienal de Física 2013
Time residual distribution for data events
Tim
e r
esi
duals
PD
F
Distribution of the quality of the reconstruction parameter for data and MC events
![Page 9: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/9.jpg)
Time calibration
A good timing of the OMs is crucial to guarantee the expected performance of the telescope.
ANTARES is designed achive an angular resolution better than 0.5º at high energies (~10 TeV)
Relative time calibrationIntra-line: synchronize all the OMs within a line with respect to a common reference (one OM in the first storey)Inter-line: calibrate all the OMs with respect to a unique (global) reference
1 Calibración temporal en ANTARESBienal de Física 2013
![Page 10: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/10.jpg)
Method description
Using physics events, time offsets are computed iteratively:
1) A probe line is (randomly) selected which hits are not used in the track reconstruction
2) Fit muon trajectory using the remaining hits3) Compute time residuals using the fitted track*
parameters4) Distribution of these residuals are histogramed and fitted
to a Gaussian (around peak) which mean value is interpreted as the line offset
5) Time offsets measured in the previous step are accounted for in a new iteration
The full process is repeated until the size of the correction is sufficiently small
1 Calibración temporal en ANTARESBienal de Física 2013
*Only rather good reconstructed events (Λ>-5.6) are used
![Page 11: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/11.jpg)
Inter-line offsets Time residual distributions for different iterations of
the procedure
1 Calibración temporal en ANTARESBienal de Física 2013
Iteration 1 Iteration 5
![Page 12: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/12.jpg)
Inter-line offsets Time offsets obtained for the 12 detection lines
1 Calibración temporal en ANTARESBienal de Física 2013
Cumulative corrections as a function of the number of iterations of the procedure
![Page 13: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/13.jpg)
Inter-line time offsets
Time offsets measured using physics runs with about 5 days livetime
1 Calibración temporal en ANTARESBienal de Física 2013
L1 L2
L5 L3 L4 L6
L9 L7 L8 L10
L11 L12
Detection lines layout
Largest offsets is found for Line 8 (where laser beacon is located)
![Page 14: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/14.jpg)
Impact on the reconstructionCorrecting the inter-line timing translates in an increase of the
number of events better reconstructed(better data/MC agreement)
1 Calibración temporal en ANTARESBienal de Física 2013
Time residual distribution fro data events
Distributions of the quality of the reconstruction parameter for vertical (left) and inclined (right) events
![Page 15: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/15.jpg)
Effect on the performanceWhy if we don’t correct the inter-line timing? By mis-calibrating the lines, and using MC simulation, we check the effect on the angular resolution
1 Calibración temporal en ANTARESBienal de Física 2013
Angular error between the reconstructed muon trajectory and the true neutrino direction: a wrong inter-line timing results in a ~40% degraded resolution
![Page 16: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/16.jpg)
Cross-check with the LBUsing the laser beacon placed at the bottom of line 8 we have cross-checked the results obtained using atmospheric muons
1 Calibración temporal en ANTARESBienal de Física 2013
Difference of the time offsets measured with these two methods
Several calibration runs are used to compute the time offset (fit to the green point)
![Page 17: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/17.jpg)
Cross-check with the LBUsing the calibration constants provided by the method using atmospheric muon data improves (slightly) the reconstruction
1 Calibración temporal en ANTARESBienal de Física 2013
Distributions of the quality of the reconstruction parameter for vertical (left) and inclined (right) events
![Page 18: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/18.jpg)
Time offsets stabilityNo variations are expected unless PMT HV tuning or
replacement of a line reference OM is performed
1 Calibración temporal en ANTARESBienal de Física 2013
![Page 19: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/19.jpg)
Intra-line timingReconstruction uses the most updated calibration constants stored in the data-base check correction to the T0’s timing first obtained using the LED Beacon system
Similar iterative procedure, but optimized to reduce the number of runs needed to accumulate good statistics
1 Calibración temporal en ANTARESBienal de Física 2013
Time residual distribution for one OM
![Page 20: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/20.jpg)
Intra-line timingReconstruction uses the most updated calibration constanst stored in the data-base check correction to the T0’s timing first obtained using the LED Beacon system
1 Calibración temporal en ANTARESBienal de Física 2013
90% of correction are smaller than 1ns
![Page 21: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/21.jpg)
Summary/Conclusions
• Time calibration is crucial to achieve the best performance of the telescope:
• A new method using atmospheric muon data has been implemented which can work out the parameters of the relative timing calibration without stopping the physics data acquisition
• Results on the inter-line timing:• Correcting the time offsets translates in up to a factor 2
enhancement of the number of good reconstructed events traversing diagonally the detector (improved data/MC agreement)
• Improvement (40%) on the angular resolution is expected• Cross-chek of the laser beacon results.• Provides the official calibration constants used for data
processing
• Ongoing progress for the T0s calibration:• Cross-check of the results with the LED beacon
1 Calibración temporal en ANTARESBienal de Física 2013
![Page 22: J.P. Gómez-González. Outline Introduction: The ANTARES neutrino telescope Time calibration Muon track residuals based method: Description and implementation.](https://reader035.fdocuments.us/reader035/viewer/2022062804/56649d835503460f94a6950d/html5/thumbnails/22.jpg)
Gracias por su atención!