Jeep Cherokee XJ 1995-1999 Electrical

24
ELECTRICAL GROUP INDEX Group Group AUDIO SYSTEMS ........................ 8F BATTERY/STARTER/GENERATOR SERVICE .... 8B BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS ......................... 8A CHIME/BUZZER WARNING SYSTEMS ........ 8U HORNS ................................ 8G IGNITION SYSTEMS ...................... 8D INSTRUMENT PANEL AND GAUGES ......... 8E LAMPS ................................ 8L OVERHEAD CONSOLE .................... 8C POWER LOCKS .......................... 8P POWER MIRRORS ....................... 8T POWER SEATS .......................... 8R POWER WINDOWS ....................... 8S REAR WINDOW DEFOGGER ............... 8N RESTRAINT SYSTEMS ................... 8M TURN SIGNAL AND HAZARD WARNING SYSTEMS ............................. 8J VEHICLE SPEED CONTROL SYSTEM ......... 8H WIPER AND WASHER SYSTEMS ............ 8K XJ WIRING DIAGRAMS-LEFT HAND DRIVE . . . 8W XJ WIRING DIAGRAMS-RIGHT HAND DRIVE . 8W YJ WIRING DIAGRAMS .................. 8W BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS CONTENTS page page BATTERY ............................... 2 CHARGING SYSTEM ..................... 17 IGNITION-OFF DRAW .................... 10 SPECIFICATIONS ........................ 23 STARTING SYSTEM ...................... 11 USING ON-BOARD DIAGNOSTIC SYSTEM .... 22 GENERAL INFORMATION The battery, starting, and charging systems operate with one another; therefore, they must be tested as a complete system. In order for the vehicle to start and charge properly, all of the components involved in these systems must perform within specifications. Group 8A covers battery, starting (Fig. 1) and charging (Fig. 2) system diagnostic procedures. These procedures include the most basic conventional diag- nostic methods, to On-Board Diagnostics (OBD) built into the Powertrain Control Module (PCM). Use of an induction milliamp ammeter, volt/ohmmeter, battery charger, carbon pile rheostat (load tester), and 12- volt test lamp will be required. All OBD-sensed systems are monitored by the PCM. Each monitored circuit is assigned a Diagnos- tic Trouble Code (DTC). The PCM will store a DTC in electronic memory for any failure it detects. See Us- ing On-Board Diagnostic System in this group for more information. J ELECTRICAL 8A - 1

description

Manual service Jeep Cherokee XJ

Transcript of Jeep Cherokee XJ 1995-1999 Electrical

  • ELECTRICAL

    GROUP INDEX

    Group Group

    AUDIO SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . 8FBATTERY/STARTER/GENERATOR SERVICE . . . . 8BBATTERY/STARTING/CHARGING SYSTEMS

    DIAGNOSTICS . . . . . . . . . . . . . . . . . . . . . . . . . 8ACHIME/BUZZER WARNING SYSTEMS . . . . . . . . 8UHORNS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8GIGNITION SYSTEMS . . . . . . . . . . . . . . . . . . . . . . 8DINSTRUMENT PANEL AND GAUGES . . . . . . . . . 8ELAMPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8LOVERHEAD CONSOLE . . . . . . . . . . . . . . . . . . . . 8CPOWER LOCKS . . . . . . . . . . . . . . . . . . . . . . . . . . 8PPOWER MIRRORS . . . . . . . . . . . . . . . . . . . . . . . 8T

    POWER SEATS . . . . . . . . . . . . . . . . . . . . . . . . . . 8RPOWER WINDOWS . . . . . . . . . . . . . . . . . . . . . . . 8SREAR WINDOW DEFOGGER . . . . . . . . . . . . . . . 8NRESTRAINT SYSTEMS . . . . . . . . . . . . . . . . . . . 8MTURN SIGNAL AND HAZARD WARNING

    SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8JVEHICLE SPEED CONTROL SYSTEM . . . . . . . . . 8HWIPER AND WASHER SYSTEMS . . . . . . . . . . . . 8KXJ WIRING DIAGRAMS-LEFT HAND DRIVE . . . 8WXJ WIRING DIAGRAMS-RIGHT HAND DRIVE . 8WYJ WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . 8W

    BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS

    CONTENTS

    page page

    BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2CHARGING SYSTEM . . . . . . . . . . . . . . . . . . . . . 17IGNITION-OFF DRAW . . . . . . . . . . . . . . . . . . . . 10

    SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . 23STARTING SYSTEM . . . . . . . . . . . . . . . . . . . . . . 11USING ON-BOARD DIAGNOSTIC SYSTEM . . . . 22

    GENERAL INFORMATIONThe battery, starting, and charging systems operate

    with one another; therefore, they must be tested as acomplete system. In order for the vehicle to start andcharge properly, all of the components involved inthese systems must perform within specifications.

    Group 8A covers battery, starting (Fig. 1) andcharging (Fig. 2) system diagnostic procedures. Theseprocedures include the most basic conventional diag-nostic methods, to On-Board Diagnostics (OBD) built

    into the Powertrain Control Module (PCM). Use of aninduction milliamp ammeter, volt/ohmmeter, batterycharger, carbon pile rheostat (load tester), and 12-volt test lamp will be required.

    All OBD-sensed systems are monitored by thePCM. Each monitored circuit is assigned a Diagnos-tic Trouble Code (DTC). The PCM will store a DTC inelectronic memory for any failure it detects. See Us-ing On-Board Diagnostic System in this group formore information.

    J ELECTRICAL 8A - 1

  • BATTERY

    GENERAL INFORMATIONThe storage battery is a device used to store elec-

    trical energy potential in a chemical form. When anelectrical load is applied to the battery terminals, anelectrochemical reaction occurs within the battery.This reaction causes the battery to discharge electri-cal current.

    The battery is made up of 6 individual cells thatare connected in series. Each cell contains positivelycharged plate groups made of lead oxide, and nega-tively charged plate groups made of sponge lead.These dissimilar metal plates are submerged in asulfuric acid and water solution called electrolyte.

    As the battery discharges, a gradual chemicalchange takes place within each cell. The sulfuric acidin the electrolyte combines with the plate materials,causing both plates to change to lead sulfate. At thesame time, oxygen from the positive plate materialcombines with hydrogen from the sulfuric acid, caus-ing the electrolyte to become mainly water.

    The chemical changes within the battery arecaused by movement of excess or free electrons be-tween the positive and negative plate groups. This

    movement of electrons produces a flow of electricalcurrent through the load device attached to the bat-tery terminals.

    As the plate materials become more similar chem-ically, and the electrolyte becomes less acid, the volt-age potential of each cell is reduced. However, bycharging the battery with a voltage higher than thatof the battery, the process is reversed.

    Charging the battery gradually changes the sul-fated lead plates back into sponge lead and lead ox-ide, and the water back into sulfuric acid. This actionrestores the difference in electron charges depositedon the plates, and the voltage potential of the batterycells.

    For a battery to remain useful, it must be able toproduce high-amperage current over an extended pe-riod. A battery must also be able to accept a charge,so that its voltage potential may be restored.

    In addition to producing and storing electrical en-ergy, the battery serves as a capacitor or voltage sta-bilizer for the vehicle electrical system. It absorbsabnormal or transient voltages caused by switchingof any of the vehicles electrical components.

    The battery is vented to release excess gas that iscreated when the battery is being charged or dis-

    Fig. 1 Starting System Components (Typical)

    Fig. 2 Charging System Components (Typical)

    8A - 2 BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS J

  • charged. However, even with these vents, hydrogengas can collect in or around the battery. If hydrogengas is exposed to flame or sparks, it can ignite.

    If the electrolyte level is low, the battery could arcinternally and explode. If the battery is equippedwith removable cell caps, add distilled water when-ever the electrolyte level is below the top of theplates. If the battery cell caps cannot be removed, thebattery must be replaced when the electrolyte level islow.

    WARNING: DO NOT ATTEMPT TO ASSIST BOOST,CHARGE, OR TEST BATTERY WHEN ELECTRO-LYTE LEVEL IS BELOW THE TOP OF THE PLATES.PERSONAL INJURY MAY OCCUR.

    BATTERY RATINGSCurrently, there are 2 commonly accepted methods

    for rating and comparing battery performance. Theseratings are called Cold Cranking Amperage (CCA),and Reserve Capacity (RC). Be certain that a replace-ment battery has CCA and RC ratings that equal orexceed the original equipment specification for thevehicle being serviced. See Battery Classificationsand Ratings charts in Specifications at the back ofthis group.

    COLD CRANKING AMPERAGEThe Cold Cranking Amperage (CCA) rating speci-

    fies how much current (in amperes) the battery candeliver for 30 seconds at -17.7C (0F). Terminal volt-age must not fall below 7.2 volts during or after the30 second discharge. The CCA required is generallyhigher as engine displacement increases, dependingalso upon the starter current draw requirements.

    RESERVE CAPACITYThe Reserve Capacity (RC) rating specifies the

    time (in minutes) it takes for battery terminal volt-age to fall below 10.2 volts at a discharge rate of 25amps. RC is determined with the battery fully-charged at 26.7C (80F). This rating estimates howlong the battery might last after a charging systemfailure, under minimum electrical load.

    DIAGNOSISThe battery must be completely charged and the

    top, posts, and terminal clamps should be properlycleaned before diagnostic procedures are performed.Refer to Group 8B - Battery/Starter/Generator Ser-vice for more information.

    The condition of a battery is determined by two cri-teria:

    (1) State-Of-Charge This can be determined byviewing the built-in test indicator, by checking spe-cific gravity of the electrolyte (hydrometer test), or bychecking battery voltage (open circuit voltage test).

    (2) Cranking Capacity This can be determinedby performing a battery load test, which measuresthe ability of the battery to supply high-amperagecurrent.

    If the battery has a built-in test indicator, use thistest first. If it has no test indicator, but has remov-able cell caps, perform the hydrometer test first. Ifcell caps are not removable, or a hydrometer is notavailable, perform the open circuit voltage test first.

    The battery must be charged before proceedingwith a load test if: the built-in test indicator has a black or dark colorvisible the temperature corrected specific gravity is lessthan 1.235 the open circuit voltage is less than 12.4 volts.

    A battery that will not accept a charge is faultyand further testing is not required. A battery that isfully-charged, but does not pass the load test isfaulty and must be replaced.

    Completely discharged batteries may takeseveral hours to accept a charge. See ChargingCompletely Discharged Battery.

    A battery is fully-charged when: all cells are gassing freely during charging a green color is visible in the sight glass of thebuilt-in test indicator three corrected specific gravity tests, taken at1-hour intervals, indicate no increase in specific grav-ity open circuit voltage is 12.4 volts or greater.

    ABNORMAL BATTERY DISCHARGINGAny of the following conditions can result in abnor-

    mal battery discharging:(1) Corroded battery posts and terminals.(2) Loose or worn generator drive belt.(3) Electrical loads that exceed the output of the

    charging system, possibly due to equipment installedafter manufacture or repeated short trip use.

    (4) Slow driving speeds (heavy traffic conditions) orprolonged idling with high-amperage draw systemsin use.

    (5) Faulty circuit or component causing excessiveignition-off draw. See Ignition-Off Draw in this groupfor diagnosis.

    (6) Faulty charging system.(7) Faulty or incorrect battery.

    BUILT-IN TEST INDICATORA test indicator (hydrometer) built into the top of

    the battery case, provides visual information for bat-tery testing (Fig. 1). It is important when using thetest indicator that the battery be level and have aclean sight glass to see correct indications. Additionallight may be required to view indicator.

    J BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS 8A - 3

  • BATTERY DIAGNOSIS

    8A - 4 BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS J

  • WARNING: DO NOT USE OPEN FLAME AS ASOURCE OF ADDITIONAL LIGHT FOR VIEWINGTEST INDICATOR. EXPLOSIVE HYDROGEN GASMAY BE PRESENT IN THE AREA SURROUNDINGBATTERY.

    Like a hydrometer, the built-in test indicator mea-sures the specific gravity of the electrolyte. Specificgravity will indicate battery state-of-charge. How-ever, the test indicator will not indicate cranking ca-pacity of the battery. See Load Test in this group formore information.

    Look into the sight glass and note the color of theindicator (Fig. 2). Refer to the following description,as the color indicates:

    GREENindicates 75% to 100% state-of-charge.The battery is adequately charged for further test-

    ing or return to use. If the vehicle will not crank fora minimum of 15 seconds with a fully-charged bat-tery, perform Load Test.

    BLACK OR DARKindicates 0% to 75% state-of-charge.

    The battery is inadequately charged and must becharged until green indicator (Fig. 2) is visible insight glass (12.4 volts or more) before the battery istested further or returned to use. See Abnormal Bat-tery Discharging in this group to diagnose cause ofdischarged condition.

    YELLOW OR BRIGHTindicates low electrolytelevel.

    The electrolyte level in the battery is below test in-dicator (Fig. 2). A maintenance-free battery with non-removable cell caps must be replaced if electrolytelevel is low. Water can be added to a low-mainte-nance battery with removable cell caps. A low electro-lyte level may be caused by an over-chargingcondition. See Charging System in this group to di-agnose an over-charging condition.

    WARNING: DO NOT ATTEMPT TO CHARGE, TEST,OR ASSIST BOOST BATTERY WHEN YELLOW ORBRIGHT COLOR IS VISIBLE IN SIGHT GLASS OFTEST INDICATOR. LOW ELECTROLYTE LEVEL CANALLOW BATTERY TO ARC INTERNALLY AND EX-PLODE. PERSONAL INJURY MAY OCCUR.

    HYDROMETER TESTThe hydrometer test reveals the battery state-of-

    charge by measuring the specific gravity of the elec-trolyte. This test cannot be performed on batterieswith non-removable cell caps. If battery has non-re-movable cell caps, see Built-In Test Indicator or OpenCircuit Voltage Test.

    Specific gravity is a comparison of the density ofthe electrolyte to the density of pure water. Pure wa-ter has a specific gravity of 1.000, and sulfuric acidhas a specific gravity of 1.835. Sulfuric acid makesup approximately 35% of the electrolyte by weight, or24% by volume.

    In a fully-charged battery the electrolyte will havea temperature corrected specific gravity of 1.260 to1.290. However, a specific gravity of 1.235 or above issatisfactory for battery load testing and/or return toservice.

    Before testing, visually inspect battery for anydamage (cracked case or cover, loose posts, etc.) thatwould cause the battery to be faulty. Then removecell caps and check electrolyte level. Add distilled wa-ter if electrolyte level is below the top of the batteryplates.

    To use the hydrometer correctly, hold it with thetop surface of the electrolyte at eye level. Refer to thehydrometer manufacturers instructions for correctuse of hydrometer. Remove only enough electrolytefrom the battery so the float is off the bottom of thehydrometer barrel with pressure on the bulb re-leased.

    Exercise care when inserting the tip of the hydrom-eter into a cell to avoid damaging the plate separa-tors. Damaged plate separators can cause prematurebattery failure.

    Hydrometer floats are generally calibrated to indi-cate the specific gravity correctly only at 26.7C(80F). When testing the specific gravity at any othertemperature, a correction factor is required.

    The correction factor is approximately a specificgravity value of 0.004, referred to as 4 points of spe-cific gravity. For each 5.5C above 26.7C (10F above80F), add 4 points. For each 5.5C below 26.7C(10F below 80F), subtract 4 points. Always correct

    Fig. 1 Built-In Test Indicator

    Fig. 2 Built-In Test Indicator Sight Glass

    J BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS 8A - 5

  • the specific gravity for temperature variation. Testthe specific gravity of the electrolyte in each batterycell.

    Example: A battery is tested at -12.2C (10F) andhas a specific gravity of 1.240. Determine the actualspecific gravity as follows:

    (1) Determine the number of degrees above or be-low 26.7C (80F):

    26.6C - -12.2C = 38.8C (80F - 10F = 70F)(2) Divide the result from step 1 by 5.5 (10):38.8C/5.5 = 7 (70F/10 = 7)(3) Multiply the result from step 2 by the temper-

    ature correction factor (0.004):7 x 0.004 = 0.028(4) The temperature at testing was below 26.7C

    (80F); therefore, the temperature correction is sub-tracted:

    1.240 - 0.028 = 1.212The corrected specific gravity of the battery in this

    example is 1.212.If the specific gravity of all cells is above 1.235, but

    variation between cells is more than 50 points(0.050), the battery should be replaced.

    If the specific gravity of one or more cells is lessthan 1.235, charge the battery at a rate of approxi-mately 5 amperes. Continue charging until 3 consec-utive specific gravity tests, taken at 1-hour intervals,are constant. If the cell specific gravity variation ismore than 50 points (0.050) at the end of the chargeperiod, replace the battery.

    When the specific gravity of all cells is above 1.235,and cell variation is less than 50 points (0.050), thebattery may be load tested.

    OPEN CIRCUIT VOLTAGE TESTA battery open circuit voltage (no load) test will

    show state-of-charge of a battery. This test can beused in place of the hydrometer test if a hydrometeris not available, or for maintenance-free batterieswith non-removable cell caps.

    Before proceeding with this test or load test,completely charge battery as described in Bat-tery Charging in this group.

    Test battery open circuit voltage as follows:(1) Before measuring open circuit voltage the sur-

    face charge must be removed from the battery. Turnheadlamps on for 15 seconds, then allow up to 5 min-utes for voltage to stabilize.

    (2) Remove both battery cables, negative first.(3) Using a voltmeter connected to the battery

    posts (refer to instructions provided with voltmeter)measure open circuit voltage (Fig. 3).

    See Open Circuit Voltage chart. This voltage read-ing will indicate state-of-charge, but will not revealcranking capacity. If a battery has an open circuitvoltage reading of 12.4 volts or greater, it may beload tested. A battery that will not endure a load testis faulty and must be replaced.

    LOAD TESTA battery load test will verify battery cranking ca-

    pacity. The test is based on the Cold Cranking Am-perage (CCA) rating of the battery. See BatteryClassifications and Ratings chart in Specifications, atthe back of this group.

    WARNING: IF BATTERY SHOWS SIGNS OF FREEZ-ING, LEAKING, LOOSE POSTS, OR LOW ELECTRO-LYTE LEVEL, DO NOT LOAD TEST. PERSONALINJURY AND/OR VEHICLE DAMAGE MAY RESULT.

    Before performing load test, the battery mustbe FULLY-CHARGED.

    (1) Remove both battery cables, negative first. Bat-tery top and posts should be clean.

    (2) Connect a suitable volt-ammeter-load tester(Fig. 4) to the battery posts (Fig. 5). Refer to operat-ing instructions provided with the tester being used.Check the open circuit voltage (no load) of the bat-tery. Open circuit voltage must be 12.4 volts orgreater.

    (3) Rotate the load control knob (carbon pile rheo-stat) to apply a 300 amp load for 15 seconds, then re-turn the control knob to OFF (Fig. 6). This willremove the surface charge from the battery.

    (4) Allow the battery to stabilize to open circuitvoltage. It may take up to 5 minutes for voltage tostabilize.

    OPEN CIRCUIT VOLTAGE

    Fig. 3 Testing Open Circuit Voltage

    8A - 6 BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS J

  • (5) Rotate the load control knob to maintain a loadequal to 50% of CCA rating (Fig. 7). After 15 seconds,record the loaded voltage reading, then return theload control knob to OFF.

    (6) Voltage drop will vary with battery tempera-ture at the time of the load test. Battery temperaturecan be estimated by the ambient temperature overthe past several hours. If the battery has beencharged, boosted, or loaded a few minutes prior to

    test, the battery will be somewhat warmer. See LoadTest Temperature chart for proper loaded voltagereading.

    (7) If the voltmeter reading falls below 9.6 volts, ata minimum battery temperature of 21C (70F), re-place the battery.

    BATTERY CHARGINGA battery is fully-charged when:

    all cells are gassing freely during charging a green color is visible in sight glass of built-intest indicator three corrected specific gravity tests, taken at1-hour intervals, indicate no increase in specific grav-ity open circuit voltage is 12.4 volts or above.

    WARNING: DO NOT ASSIST BOOST OR CHARGE ABATTERY THAT HAS LOW ELECTROLYTE LEVELOR IS FROZEN. BATTERY MAY ARC INTERNALLYAND EXPLODE.

    WARNING: EXPLOSIVE HYDROGEN GAS FORMS INAND AROUND BATTERY. DO NOT SMOKE, USEFLAME, OR CREATE SPARKS NEAR BATTERY.

    Fig. 4 Volt-Amps-Load Tester (Typical)

    Fig. 5 Volt-Ammeter-Load Tester Connections

    Fig. 6 Remove Surface Charge from Battery

    Fig. 7 Load 50% CCA Rating - Note Voltage

    J BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS 8A - 7

  • WARNING: POISONOUS AND CAUSTIC. BATTERYCONTAINS SULFURIC ACID. AVOID CONTACT WITHSKIN, EYES, OR CLOTHING. IN EVENT OF CON-TACT, FLUSH WITH WATER AND CALL PHYSICIANIMMEDIATELY. KEEP OUT OF REACH OF CHIL-DREN.

    CAUTION: Always disconnect the battery negativecable before charging battery to avoid damage toelectrical system components. Do not exceed 16.0volts while charging battery.

    Battery electrolyte will bubble inside battery caseduring normal battery charging. If the electrolyteboils, or is discharged from the vent holes whilecharging, immediately reduce charging rate or turnOFF charger and evaluate battery condition.

    Battery should not be hot to the touch. If thebattery feels hot to the touch, turn OFFcharger and let battery cool before continuingcharging operation.

    Some battery chargers are equipped with polaritysensing circuitry. This circuitry protects the chargerand/or battery from being damaged if improperly con-nected.

    If the battery state-of-charge is too low for the po-larity sensing circuitry to detect, the charger will notoperate. This makes it appear that the battery willnot accept charging current. Refer to instructionsprovided with the battery charger being used to by-pass the polarity sensing circuitry.

    After the battery has been charged to 12.4 volts orgreater, perform a load test to determine crankingcapacity. If the battery will endure a load test, returnthe battery to use. If the battery will not endure aload test, it must be replaced.

    Clean and inspect battery holddowns, tray, termi-nals, posts, and top before completing service. Referto Group 8B - Battery/Starter/Generator Service formore information.

    CHARGING TIME REQUIREDThe time required to charge a battery will vary, de-

    pending upon the following factors:

    (1) Battery CapacityA completely dischargedheavy-duty battery requires twice the rechargingtime of a small capacity battery.

    WARNING: NEVER EXCEED 20 AMPS WHENCHARGING A COLD (-1C/30F) BATTERY. PER-SONAL INJURY MAY RESULT.

    (2) TemperatureA longer time will be needed tocharge a battery at -18C (0F) than at 27C (80F).When a fast charger is connected to a cold battery,current accepted by the battery will be very low atfirst. As the battery warms, it will accept a highercharging current rate.

    (3) Charger CapacityA charger that suppliesonly 5 amperes will require a longer charging time. Acharger that supplies 20 amperes or more requires ashorter charging time.

    (4) State-Of-ChargeA completely dischargedbattery requires more charging time than a partiallydischarged battery. Electrolyte is nearly pure waterin a completely discharged battery. At first, thecharging current (amperage) will be low. As the bat-tery charges, the specific gravity of the electrolytewill gradually rise.

    CHARGING COMPLETELY DISCHARGEDBATTERY

    The following procedure should be used to rechargea completely discharged battery. Unless this proce-dure is properly followed, a good battery may beneedlessly replaced.

    (1) Measure voltage at battery posts with a voltme-ter, accurate to 1/10 (0.10) volt (Fig. 8). If the readingis below 10 volts, the charge current will be low. Itcould take some time before the battery accepts acurrent greater than a few milliamperes. Such lowcurrent may not be detectable on ammeters built intomany chargers.

    (2) Disconnect battery negative cable. Connectcharger leads. Some battery chargers are equipped

    BATTERY CHARGING TIME TABLE

    Fig. 8 Voltmeter Accurate to 1/10 Volt Connected

    8A - 8 BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS J

  • with polarity sensing circuitry. This circuitry protectsthe charger and/or battery from being damaged if im-properly connected. If the battery state-of-charge istoo low for the polarity sensing circuitry to detect,the charger will not operate. This makes it appearthat the battery will not accept charging current. Re-fer to the instructions provided with the batterycharger to bypass the polarity sensing circuitry.

    (3) Battery chargers vary in the amount of voltageand current they provide. The amount of time re-quired for a battery to accept measurable chargercurrent at various voltages is shown in Charge Ratechart. If charge current is still not measurable at endof charging times, the battery should be replaced. Ifcharge current is measurable during charging time,

    the battery may be good and charging should be com-pleted in the normal manner.

    CHARGE RATE

    J BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS 8A - 9

  • IGNITION-OFF DRAW

    GENERAL INFORMATIONIgnition-Off Draw (IOD) refers to power being

    drained from the battery with the ignition switchturned OFF. A normal vehicle electrical system willdraw from 5 to 20 milliamps (0.005 - 0.020 amps).This is with the ignition switch in the OFF position,and all non-ignition controlled circuits in properworking order. The 20 milliamps are needed to sup-ply PCM memory, digital clock memory, and electron-ically-tuned radio memory.

    A vehicle that has not been operated for approxi-mately 20 days, may discharge the battery to an in-adequate level. When a vehicle will not be used for20 days or more (stored), remove the IOD fuse in thePower Distribution Center (PDC). This will reducebattery discharging.

    Excessive battery drain can be caused by: electrical items left on faulty or improperly adjusted switches internally shorted generator intermittent shorts in the wiring.

    If the IOD is over 20 milliamps, the problem mustbe found and corrected before replacing a battery. Inmost cases, the battery can be charged and returnedto service.

    DIAGNOSISTesting for high-amperage IOD must be per-

    formed first to prevent damage to most milli-amp meters.

    (1) Verify that all electrical accessories are off.Turn off all lamps, remove ignition key, and close alldoors. If the vehicle is equipped with illuminated en-try or electronically-tuned radio, allow the systems toautomatically shut off (time out). This may take upto 3 minutes.

    (2) Determine that the underhood lamp is operat-ing properly, then disconnect or remove bulb.

    (3) Disconnect negative cable from battery.(4) Connect a typical 12-volt test lamp (low-watt-

    age bulb) between the negative cable clamp and thebattery negative terminal. Make sure that the doorsremain closed so that illuminated entry is not acti-vated.

    The test lamp may light brightly for up to 3 min-utes, or may not light at all, depending upon the ve-hicles electrical equipment. The term brightly, asused throughout the following tests, implies thebrightness of the test lamp will be the same as if itwere connected across the battery.

    The test lamp must be securely clamped to the neg-ative cable clamp and battery negative terminal. Ifthe test lamp becomes disconnected during any partof the IOD test, the electronic timer function will beactivated and all tests must be repeated.

    (5) After 3 minutes the test lamp should turn offor be dimly lit, depending upon the vehicles electri-cal equipment. If the test lamp remains brightly lit,do not disconnect it. Remove each fuse or circuitbreaker (refer to Group 8W - Wiring Diagrams) untiltest lamp is either off or dimly lit. This will isolateeach circuit and identify the source of the high-am-perage draw.

    If the test lamp is still brightly lit after disconnect-ing each fuse and circuit breaker, disconnect the wir-ing harness from the generator. If test lamp nowturns off or is dimly lit, see Charging System in thisgroup to diagnose faulty generator. Do not disconnectthe test lamp.

    After high-amperage IOD has been corrected, low-amperage IOD may be checked. It is now safe to in-stall a milliamp meter to check for low- amperageIOD.

    (6) With test lamp still connected securely, clamp amilliamp meter between battery negative terminaland negative cable clamp.

    Do not open any doors or turn on any electri-cal accessories with the test lamp disconnectedor the milliamp meter may be damaged.

    (7) Disconnect test lamp. Observe milliamp meter.The current draw should not exceed 0.020 amp. Ifdraw exceeds 20 milliamps, isolate each circuit by re-moving circuit breakers and fuses. The milliampmeter reading will drop when the source of the drawis disconnected. Repair this circuit as necessary,whether a wiring short, incorrect switch adjustmentor a component failure is found.

    8A - 10 BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS J

  • STARTING SYSTEM

    GENERAL INFORMATIONThe starting system (Fig. 1) consists of:

    ignition switch starter relay park/neutral position switch (automatic transmis-sion) wiring harness and connections battery starter with an integral solenoid.

    Following is a general description of the majorstarting system components. Refer to Group 8W -Wiring Diagrams for complete circuit descriptionsand diagrams.

    These components form 2 separate circuits. A high-amperage feed circuit that feeds the starter up to300+ amps, and a low-amperage control circuit thatoperates on less than 20 amps.

    Battery voltage is supplied through the low-amper-age control circuit to the coil battery terminal of thestarter relay when the ignition switch is turned tothe START position.

    If the vehicle is equipped with an automatic trans-mission, the park/neutral position switch provides aground path to the starter relay coil ground terminal.This switch provides ground only with the transmis-sion in NEUTRAL or PARK. If the vehicle isequipped with a manual transmission, the starter re-lay coil ground terminal is always grounded.

    With the starter relay coil now energized, the nor-mally open relay contacts close. The relay contactsconnect the relay common feed terminal to the relaynormally open terminal. The closed relay contacts en-ergize the starter solenoid coil windings.

    The energized solenoid coils pull-in and hold-in thesolenoid plunger. The solenoid plunger pulls the shift

    lever in the starter. This engages the starter overrun-ning clutch and pinion gear with the flywheel/driveplate ring gear.

    As the solenoid plunger reaches the end of itstravel, the solenoid contact disc completes the high-amperage starter feed circuit. Current now flows be-tween the solenoid battery terminal and the startermotor, energizing the starter.

    Once the engine starts, the overrunning clutch pro-tects the starter from damage by allowing the starterpinion gear to spin faster than the pinion shaft.When the driver releases the ignition switch to theON position the starter relay coil is de-energized.This causes the relay contacts to open. When the re-lay contacts open, the starter solenoid coil is de-ener-gized.

    When the solenoid coil is de-energized, the solenoidplunger return spring returns the plunger to its re-laxed position. This causes the contact disc to openthe starter feed circuit, and the shift lever to disen-gage the overrunning clutch and pinion gear from thering gear.

    The starter motor and solenoid are serviced only asa complete assembly. If either component fails, theentire assembly must be replaced.

    DIAGNOSISBefore removing any unit from the starting system

    for repair, perform the following inspections:

    INSPECTION

    BATTERY INSPECTIONTo determine condition of the battery, see Battery

    in this group.

    WIRING INSPECTIONInspect wiring for damage. Inspect all connections

    at: starter solenoid park/neutral position switch (automatic transmis-sion) ignition switch starter relay battery (including all ground connections).

    Clean, tighten and repair all connections as re-quired.

    SOLENOID, RELAY AND SWITCH INSPECTIONSInspect the solenoid, relay and ignition switch to

    determine their condition. Also, if equipped with au-tomatic transmission, inspect condition of the park/neutral position switch. Testing information can befound in the following pages.

    Fig. 1 Starting System Components (Typical)

    J BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS 8A - 11

  • STARTING SYSTEM DIAGNOSIS

    8A - 12 BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS J

  • COLD CRANKING TEST(1) Battery must be fully-charged and load tested

    before proceeding. See Battery, in this group.(2) Connect a suitable volt-ampere tester to the

    battery terminals (Fig. 2). Refer to the operating in-structions provided with the tester being used.

    (3) Fully engage parking brake. Place manualtransmission in NEUTRAL, automatic transmissionin PARK.

    (4) Verify that all lamps and accessories are OFF.(5) Unplug Auto Shut-Down (ASD) relay from

    Power Distribution Center (PDC) to prevent enginefrom starting. Relay location is shown on undersideof PDC cover.

    (6) Rotate and hold the ignition switch in the STARTposition. Note cranking voltage and amperage.

    (a) If voltage reads above 9.6 volts and amperagedraw reads above specifications, see Feed Circuit Tests.

    (b) If voltage reads 12.5 volts or greater and am-perage reads below specifications, see Control Cir-cuit Tests.A cold engine will increase starter current

    and reduce battery voltage.

    FEED CIRCUIT TESTSThe starter feed circuit tests (voltage drop method)

    will determine if there is excessive resistance in thehigh-amperage circuit. When performing these tests,it is important that the voltmeter be connected prop-erly. Connect voltmeter leads to the terminals thatthe cable connectors or clamps are attached to, not tothe cable connectors or clamps. For example: Whentesting between the battery and solenoid, touch thevoltmeter leads to the battery post and the solenoidthreaded stud.

    The following operation will require a voltmeter ac-curate to 1/10 (0.10) volt. Before performing the tests,be certain the following procedures are accomplished: unplug Auto Shut-Down (ASD) relay from PowerDistribution Center (PDC) to prevent engine fromstarting

    place transmission in NEUTRAL (manual trans-mission) or PARK (automatic transmission) parking brake is applied battery is fully-charged (see Battery, in this group).

    (1) Connect positive lead of voltmeter to batterynegative post. Connect negative lead of voltmeter tobattery negative cable clamp (Fig. 3). Rotate andhold ignition switch in the START position. Observevoltmeter. If voltage is detected, correct poor contactbetween cable clamp and post.

    (2) Connect positive lead of voltmeter to batterypositive post. Connect negative lead of voltmeter tobattery positive cable clamp (Fig. 3). Rotate and holdignition switch in the START position. Observe volt-meter. If voltage is detected, correct poor contact be-tween cable clamp and post.

    (3) Connect voltmeter to measure between the bat-tery positive post and the starter solenoid batterystud (Fig. 4). Rotate and hold ignition switch in theSTART position. Observe voltmeter. If voltage readsabove 0.2 volt, correct poor contact at battery cable tosolenoid connection. Repeat test. If reading is stillabove 0.2 volt, replace battery positive cable.

    Fig. 2 Volt-Amps Tester Connections (Typical)

    Fig. 3 Test Battery Connection Resistance

    Fig. 4 Test Battery Positive Cable Resistance(Typical)

    J BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS 8A - 13

  • (4) Connect voltmeter to measure between the bat-tery negative post and a good clean ground on theengine block (Fig. 5). Rotate and hold ignition switchin the START position. Observe voltmeter. If voltagereads above 0.2 volt, correct poor contact at batterynegative cable attaching point. Repeat test. If read-ing is still above 0.2 volt, replace battery negative ca-ble.

    (5) Connect positive lead of voltmeter to starterhousing. Connect negative lead of voltmeter to bat-tery negative terminal (Fig. 6). Rotate and hold igni-tion switch in the START position. Observevoltmeter. If voltage reads above 0.2 volt, correct poorstarter to engine ground.

    If resistance tests detect no feed circuit problems,remove the starter and see Solenoid Test in thisgroup.

    CONTROL CIRCUIT TESTSThe starter control circuit consists of:

    starter solenoid starter relay ignition switch park/neutral position switch (automatic transmis-sion)

    wiring harness and connections.Test procedures for these components are as fol-

    lows, and should be followed in the order described.

    CAUTION: Before performing any test, unplug AutoShut-Down (ASD) relay from Power DistributionCenter (PDC) to prevent engine from starting.

    SOLENOID TESTRefer to Group 8B - Battery/Starter/Generator Ser-

    vice for starter removal procedures.(1) Disconnect solenoid field coil wire from field

    coil terminal.(2) Check for continuity between solenoid terminal

    and field coil terminal with a continuity tester. Thereshould be continuity (Fig. 7).

    (3) Check for continuity between solenoid terminaland solenoid case. There should be continuity (Fig.8).

    (4) If there is continuity, solenoid is good. If thereis no continuity in either test, solenoid has an opencircuit and is faulty. Replace starter assembly.

    (5) Connect solenoid field coil wire to field coil ter-minal.

    (6) Install starter as described in Group 8B - Bat-tery/Starter/Generator Service.

    RELAY TESTThe starter relay is in the Power Distribution Cen-

    ter (PDC)(Figs. 9 or 10). Refer to the underside of thePDC cover for relay location.

    Fig. 5 Test Ground Circuit Resistance

    Fig. 6 Test Starter Ground (Typical)

    Fig. 7 Continuity Test Between Solenoid Terminaland Field Coil Terminal

    Fig. 8 Continuity Test Between Solenoid Terminaland Solenoid Case

    8A - 14 BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS J

  • Remove starter relay from PDC to perform the fol-lowing tests:

    (1) A relay in the de-energized position shouldhave continuity between terminals 87A and 30, andno continuity between terminals 87 and 30. If OK, goto next step. If not OK, replace faulty relay.

    (2) Resistance between terminals 85 and 86 (elec-tromagnet) should be 7565 ohms. If OK, go to nextstep. If not OK, replace faulty relay.

    (3) Connect a battery to terminals 85 and 86.There should now be continuity between terminals30 and 87, and no continuity between terminals 87Aand 30. If OK, go to Relay Circuit Test. If not OK,replace faulty relay.

    RELAY CIRCUIT TEST(1) The common feed terminal (30) is connected to

    battery voltage and should be hot at all times. If OK,go to next step. If not OK, check circuit to fuse (F4for YJ, F10 for XJ) in Power Distribution Center(PDC). Repair as required.

    (2) The normally closed terminal (87A) is con-nected to terminal 30 in the de-energized position,but is not used for this application. Go to next step.

    (3) The normally open terminal (87) is connected tothe battery terminal (30) in the energized position.This terminal supplies battery voltage to the startersolenoid field coils. There should be continuity be-tween cavity for relay terminal 87 and the starter so-lenoid terminal at all times. If OK, go to next step. Ifnot OK, repair circuit to solenoid as required.

    (4) The coil battery terminal (86) is connected tothe electromagnet in the relay. It is energized whenthe ignition switch is in the START position. Checkfor battery voltage at cavity for relay terminal 86

    with ignition switch in the START position. If OK, goto next step. If not OK, refer to Group 8D - IgnitionSystems for testing and service of the ignition switch.

    (5) The coil ground terminal (85) is connected tothe electromagnet in the relay. On vehicles with anautomatic transmission, it is grounded through thepark/neutral position switch. On vehicles with amanual transmission, it is grounded at all times.Check for continuity to ground at cavity for relay ter-minal 85. If not OK and vehicle has manual trans-mission, repair circuit as required. If not OK andvehicle has automatic transmission, refer to Group21 - Transmission and Transfer Case for testing andservice of the park/neutral position switch.

    Fig. 9 Power Distribution CenterXJ

    Fig. 10 Power Distribution CenterYJ

    STARTER RELAY CONNECTIONS

    J BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS 8A - 15

  • IGNITION SWITCH TESTRefer to Group 8D - Ignition Systems for testing

    and service of this component.

    PARK/NEUTRAL POSITION SWITCH TESTRefer to Group 21 - Transmission and Transfer

    Case for testing and service of this component.

    2.5L STARTER NOISE DIAGNOSISSee Starter Noise Diagnosis chart. If the complaint

    is similar to Conditions 1 and 2 in chart, correctioncan be achieved by shimming starter according to thefollowing procedures:

    Disconnect the battery negative cable to pre-vent inadvertent starting of engine.

    (1) If the complaint is similar to Condition 1, thestarter must be moved toward the flywheel/driveplate ring gear by removing shims (Fig. 11).

    Shim thickness is 0.381 mm (0.015 in.) andshims may be stacked if required.

    (2) If the complaint is similar to Condition 2, thestarter must be moved away from the flywheel/driveplate ring gear. This is done by installing shim(s)across both mounting pads. More than one shim maybe required.

    This is generally a condition that causes bro-ken flywheel/drive plate ring gear teeth or bro-ken starter housings.

    STARTER NOISE DIAGNOSIS

    Fig. 11 Starter Shim

    8A - 16 BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS J

  • CHARGING SYSTEM

    GENERAL INFORMATIONThe charging system consists of:

    generator voltage regulator circuitry (within PCM) ignition switch battery generator warning lamp or voltmeter (dependingon vehicle equipment) wiring harness and connections.

    Following is a general description of the majorcharging system components. Refer to Group 8W -Wiring Diagrams for complete circuit descriptionsand diagrams.

    The charging system is turned on and off with theignition switch. When the ignition switch is turned tothe ON position, battery voltage is applied to thegenerator rotor through one of the two field termi-nals to produce a magnetic field. The generator isdriven by the engine through a serpentine belt andpulley arrangement.

    As the energized rotor begins to rotate within thegenerator, the spinning magnetic field induces a cur-rent into the windings of the stator coil. Once thegenerator begins producing sufficient current, it alsoprovides the current needed to energize the rotor.

    The wye (Y) type stator winding connections de-liver the induced AC current to 3 positive and 3 neg-ative diodes for rectification. From the diodes,rectified DC current is delivered to the vehicle elec-trical system through the generator battery andground terminals.

    The amount of DC current produced by the gener-ator is controlled by the generator voltage regulator(field control) circuitry, contained within the Power-train Control Module (PCM)(Fig. 1). This circuitry isconnected in series with the second rotor field termi-nal and ground.

    Voltage is regulated by cycling the ground path tocontrol the strength of the rotor magnetic field. Thegenerator voltage regulator circuitry monitors systemline voltage and ambient temperature. It then com-pensates and regulates generator current output ac-cordingly.

    The generator is serviced only as a complete as-sembly. If the generator fails for any reason, the en-tire assembly must be replaced. The generatorvoltage regulator (field control) circuitry can be ser-viced only by replacing the entire PCM.

    All vehicles are equipped with On-Board Diagnos-tics (OBD). All OBD-sensed systems, including thegenerator voltage regulator (field control) circuitry,are monitored by the PCM. Each monitored circuit isassigned a Diagnostic Trouble Code (DTC). The PCMwill store a DTC in electronic memory for any failure

    it detects. See Using On-Board Diagnostic System inthis group for more information.

    DIAGNOSISWhen operating normally, the indicator lamp on

    models with the base instrument cluster will lightwhen the ignition switch is turned to the ON orSTART position. After the engine starts, the indicatorlamp goes off. With the engine running, the chargeindicator lamp should light only when there is aproblem in the charging system (base cluster only).

    On models with a voltmeter, when the ignitionswitch is turned to the ON position, battery potentialwill register on the meter. During engine cranking alower voltage will appear on the meter. With the en-gine running, a voltage reading higher than the firstreading (ignition in ON) should register.

    The following procedures may be used to diagnosethe charging system if: the indicator or voltmeter do not operate properly an undercharged or overcharged battery conditionoccurs.

    Remember that an undercharged battery is oftencaused by:

    Fig. 1 Charging System Components (Typical)

    J BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS 8A - 17

  • accessories being left on with the engine not run-ning a faulty or improperly adjusted switch that allowsa lamp to stay on (see Ignition-Off Draw, in thisgroup).

    INSPECTION(1) Inspect condition of battery cable terminals,

    battery posts, connections at engine block, starter so-lenoid and relay. They should be clean and tight. Re-pair as required.

    (2) Inspect all fuses in the fuseblock module andPower Distribution Center (PDC) for tightness in re-ceptacles. They should be properly installed andtight. Repair or replace as required.

    (3) Inspect the electrolyte level in the battery. Ifcell caps are removable, add water if required. If cellcaps are not removable, replace battery if electrolytelevel is low.

    (4) Inspect generator mounting bolts for tightness.Replace or tighten bolts, if required. Refer to Group8B - Battery/Starter/Generator Service for torquespecifications.

    (5) Inspect generator drive belt condition and ten-sion. Tighten or replace belt as required. Refer toBelt Tension Specifications in Group 7 - Cooling Sys-tem.

    (6) Inspect connections at generator field, batteryoutput, and ground terminals. Also check ground con-nection at engine. They should all be clean and tight.Repair as required.

    OUTPUT WIRE RESISTANCE TESTThis test will show the amount of voltage drop

    across the generator output wire, from the generatorbattery terminal to the battery positive post.

    PREPARATION(1) Before starting test make sure vehicle has a

    fully-charged battery. See Battery in this group formore information.

    (2) Turn ignition switch to OFF.(3) Disconnect negative cable from battery.(4) Disconnect generator output wire from genera-

    tor battery output terminal.(5) Connect a 0-150 ampere scale DC ammeter

    (Fig. 2). Install in series between generator batteryoutput terminal and disconnected generator outputwire. Connect positive lead to generator battery out-put terminal and negative lead to disconnected gen-erator output wire.

    (6) Connect positive lead of a test voltmeter (range0-18 volts minimum) to disconnected generator out-put wire. Connect negative lead of test voltmeter tobattery positive cable at positive post.

    (7) Connect one end of a jumper wire to groundand with other end probe green K20 field wire atback of generator (Fig. 2). This will generate a DTC.

    CAUTION: Do not connect green/orange A142 fieldwire to ground. Refer to Group 8W - Wiring Dia-grams for more information.

    (8) Connect an engine tachometer, then connectbattery negative cable to battery.

    (9) Connect a variable carbon pile rheostat be-tween battery terminals. Be sure carbon pile is inOPEN or OFF position before connecting leads. SeeLoad Test in this group for instructions.

    TEST(1) Start engine. Immediately after starting, re-

    duce engine speed to idle.(2) Adjust engine speed and carbon pile to main-

    tain 20 amperes flowing in circuit. Observe voltmeterreading. Voltmeter reading should not exceed 0.5volts.

    RESULTSIf a higher voltage drop is indicated, inspect, clean

    and tighten all connections. This includes any con-nection between generator battery output terminaland battery positive post. A voltage drop test may beperformed at each connection to locate the connectionwith excessive resistance. If resistance tests satisfac-torily, reduce engine speed, turn OFF carbon pile andturn OFF ignition switch.

    (1) Disconnect negative cable from battery.(2) Remove test ammeter, voltmeter, carbon pile,

    and tachometer.(3) Remove jumper wire.(4) Connect generator output wire to generator

    battery output terminal. Tighten nut to 8.561.5 Nzm(75615 in. lbs.).

    (5) Connect negative cable to battery.(6) Use DRB scan tool to erase DTC.

    CURRENT OUTPUT TESTThe generator current output test determines

    whether generator can deliver its rated current out-put.

    PREPARATION(1) Before starting test make sure vehicle has a

    fully-charged battery. See Battery in this group formore information.

    (2) Disconnect negative cable from battery.(3) Disconnect generator output wire at the gener-

    ator battery output terminal.(4) Connect a 0-150 ampere scale DC ammeter

    (Fig. 3). Install in series between generator batteryoutput terminal and disconnected generator outputwire. Connect positive lead to generator battery out-put terminal and negative lead to disconnected gen-erator output wire.

    8A - 18 BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS J

  • (5) Connect positive lead of a test voltmeter (range0-18 volts minimum) to generator battery output ter-minal.

    (6) Connect negative lead of test voltmeter to agood ground.

    (7) Connect an engine tachometer, then connectbattery negative cable to battery.

    (8) Connect a variable carbon pile rheostat be-tween battery terminals. Be sure carbon pile is inOPEN or OFF position before connecting leads. SeeLoad Test in this group for instructions.

    (9) Connect one end of a jumper wire to groundand with other end probe green K20 field wire atback of generator (Fig. 3). This will generate a DTC.

    CAUTION: Do not connect green/orange A142 fieldwire to ground. Refer to Group 8W - Wiring Dia-grams for more information.

    TEST(1) Start engine. Immediately after starting, re-

    duce engine speed to idle.(2) Adjust carbon pile and engine speed in incre-

    ments until a speed of 1250 rpm and voltmeter read-ing of 15 volts is obtained.

    CAUTION: Do not allow voltage meter to read above16 volts.

    (3) The ammeter reading must be within limitsshown in Generator Output Voltage Specifications.

    RESULTS(1) If reading is less than specified and generator

    output wire resistance is not excessive, generatorshould be replaced. Refer to Group 8B - Battery/Starter/Generator Service.

    CHARGING SYSTEM DIAGNOSIS

    J BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS 8A - 19

  • (2) After current output test is completed, reduceengine speed, turn OFF carbon pile and turn OFF ig-nition switch.

    (3) Disconnect negative cable from battery.(4) Remove test ammeter, voltmeter, tachometer

    and carbon pile.

    (5) Remove jumper wire (Fig. 3).(6) Connect generator output wire to generator

    battery output terminal. Tighten nut to 8.561.5 Nzm(75615 in. lbs.).

    (7) Connect negative cable to battery.(8) Use DRB scan tool to erase DTC.

    Fig. 2 Generator Output Wire Resistance Test (Typical)

    8A - 20 BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS J

  • Fig. 3 Generator Current Output Test (Typical)

    J BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS 8A - 21

  • USING ON-BOARD DIAGNOSTIC SYSTEM

    GENERAL INFORMATIONThe Powertrain Control Module (PCM) monitors

    critical input and output circuits of the charging sys-tem, making sure they are operational. A DiagnosticTrouble Code (DTC) is assigned to each input andoutput circuit monitored by the OBD system. Somecircuits are checked continuously and some arechecked only under certain conditions.

    If the OBD system senses that a monitored circuitis bad, it will put a DTC into electronic memory. TheDTC will stay in electronic memory as long as thecircuit continues to be bad. The PCM is programmedto clear the memory after 50 engine starts, if theproblem does not occur again.

    DIAGNOSTIC TROUBLE CODESDiagnostic Trouble Codes (DTC) are two-digit num-

    bers flashed on the malfunction indicator (Check En-gine) lamp that identify which circuit is bad. A DTCdescription can also be read using the DRB scan tool.Refer to Group 14 - Fuel Systems for more informa-tion.

    A DTC does not identify which component in a cir-cuit is bad. Thus, a DTC should be treated as asymptom, not as the cause for the problem. In somecases, because of the design of the diagnostic testprocedure, a DTC can be the reason for another DTC

    to be set. Therefore, it is important that the test pro-cedures be followed in sequence, to understand whatcaused a DTC to be set.

    See Generator Diagnostic Trouble Code chart forDTCs which apply to the charging system. Refer tothe Powertrain Diagnostic Procedures manual to di-agnose an on-board diagnostic system trouble code.

    RETRIEVING DIAGNOSTIC TROUBLE CODESTo start this function, cycle the ignition switch ON-

    OFF-ON-OFF-ON within 5 seconds. This will causeany DTC stored in the PCM memory to be displayed.The malfunction indicator (Check Engine) lamp willdisplay a DTC by flashing on and off. There is ashort pause between flashes and a longer pause be-tween digits. All DTCs displayed are two-digit num-bers, with a four-second pause between codes.

    An example of a DTC is as follows:(1) Lamp on for 2 seconds, then turns off.(2) Lamp flashes 4 times pauses and then flashes 1

    time.(3) Lamp pauses for 4 seconds, flashes 4 times,

    pauses, then flashes 7 times.The two DTCs are 41 and 47. Any number of

    DTCs can be displayed, as long as they are in mem-ory. The lamp will flash until all stored DTCs aredisplayed (55 = end of test).

    GENERATOR DIAGNOSTIC TROUBLE CODE

    8A - 22 BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS J

  • SPECIFICATIONS

    BATTERY SPECIFICATIONS

    STARTING SYSTEM SPECIFICATIONS

    CHARGING SYSTEM SPECIFICATIONS

    2.5L STARTER AND SOLENOID TESTINGSPECIFICATIONS

    GENERATOR RATINGS

    BATTERY CLASSIFICATIONS AND RATINGS

    4.0L STARTER AND SOLENOID TESTINGSPECIFICATIONS

    4.0L STARTING SYSTEM COLD CRANKINGSPECIFICATIONS

    2.5L STARTING SYSTEM COLD CRANKINGSPECIFICATIONS

    OUTPUT VOLTAGE SPECIFICATIONS

    J BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS 8A - 23

  • ELECTRICALBATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICSBATTERYGENERAL INFORMATIONBATTERY RATINGSCOLD CRANKING AMPERAGEABNORMAL BATTERY DISCHARGINGRESERVE CAPACITY

    DIAGNOSISBUILT-IN TEST INDICATORBATTERY DIAGNOSISHYDROMETER TESTOPEN CIRCUIT VOLTAGELOAD TESTOPEN CIRCUIT VOLTAGE TEST

    BATTERY CHARGINGCHARGING COMPLETELY DISCHARGED BATTERYBATTERY CHARGING TIME TABLECHARGING TIME REQUIREDCHARGE RATE

    IGNITION-OFF DRAWGENERAL INFORMATIONDIAGNOSIS

    STARTING SYSTEMGENERAL INFORMATIONDIAGNOSISINSPECTIONSTARTING SYSTEM DIAGNOSISCOLD CRANKING TESTFEED CIRCUIT TESTSCONTROL CIRCUIT TESTSSTARTER RELAY CONNECTIONS

    2.5L STARTER NOISE DIAGNOSISSTARTER NOISE DIAGNOSIS

    CHARGING SYSTEMGENERAL INFORMATIONDIAGNOSISINSPECTIONOUTPUT WIRE RESISTANCE TESTCURRENT OUTPUT TESTCHARGING SYSTEM DIAGNOSIS

    USING ON-BOARD DIAGNOSTIC SYSTEMGENERAL INFORMATIONRETRIEVING DIAGNOSTIC TROUBLE CODESDIAGNOSTIC TROUBLE CODESGENERATOR DIAGNOSTIC TROUBLE CODE

    SPECIFICATIONSBATTERY SPECIFICATIONS\BATTERY CLASSIFICATIONS AND RATINGS

    STARTING SYSTEM SPECIFICATIONS4.0L STARTER AND SOLENOID TESTING SPECIFICATIONS4.0L STARTING SYSTEM COLD CRANKING 2.5L STARTER AND SOLENOID TESTING2.5L STARTING SYSTEM COLD CRANKING

    CHARGING SYSTEM SPECIFICATIONSOUTPUT VOLTAGE SPECIFICATIONS SPECIFICATIONSGENERATOR RATINGS