Marine Cables TRATOS MARINE are our range of cables that have been specifically designed to provide an exceptionally high quality yet cost-effective solution for shipyards also for onboard ships. In addition to their competitive intrinsic cost, Tratos Marine cables are also lightweight, thereby offering cost savings in terms of installation and operation.

Characteristics

• Reduced installation cost due to cable flexibility • Low bending radius • Reduced weight and dimensions • Reduced installation time

Safety characteristics

• Cables for fixed installation on ship• Halogen free• Low smoke and gas emissions adhering to standard IEC 61034 for smoke and IEC 60754 for acid and toxic gases• Low toxicity and corrosion• Flame retardant IEC 60332-3a IEC 60332-1*• Self-extinguishing, adhering to standard IEC 60332-3A • Fire resistant, adhering to standard IEC 60331

33

Key Customers

4

Quality Approvals

Facilities

Products

Case Studies

6

Case studies

Company: MSC

Type: Low and medium tension cablesTratos has supplied MSC cables for several applications.

Company: FINCANTIERI

Type: Low and medium tension cables

Tratos has supplied Fincantieri cables for several applications.

Company: MAERSK

Type: TRATOS AMP

Tratos has supplied since 2004 cables for an alternative marine power system.

Company: Ministero della Difesa Italiano

Type: TRATOS AMP

Tratos has supplied cables for an alternative marine power system on the Navy Cavour.

7

References

Royal Navy - UK

Devenport - UK

Port of Los Angeles - USA

Swedish Navy - Sweden

Qatar Petroleum Co - Qatar

Kuwait oil Co - Kuwait

Finnlines - Finland

Halil cement Co - Kuwait

Stockholm Port - Sweden

Gothenburg Harbour - Denmark

Odense Harbour - Denmark

Wudam Navy base - Oman

Evergreen - Taiwan

Stora Enso - Finland

Malmš Port - Sweden

Kirkness - Norway

Limhamms Port - Sweden

Ršnneport - Denmark

Grisslehamn - Sweden

Helsinki Port - Finland

Finnish navy - Finland

Helsinborg Port - Sweden

Karlskrona Port - Sweden

U.S. Coast Guard - USA

NYK - Japan

China Shipping Lines - China

P&O Nedlloyd - Netherlands

Petor Doeble - Germany

Port of Long Beach - USA

MSC - Switzerland

Yang Ming - Taiwan

MOL - Japan

Italia Marittima - Italy

BP - UK

Stora Enso - Finland

Marine Cables

9

Marine Cables

TRATOS AMP®TRATOSGREEN AMP® - ES3(N) TSCGEWÖU

Medium voltage power cables - (N) TSCGEWÖU VDE 0250 p. 813 (as applicable) & HD 620 S1 p.9Medium voltage power cables suitable for mono spiral reels up to 300m/min and multi-spiral reels up to 180 m/min.

TRATOS AMP - (N) TSGEWÖU A range of medium voltage rubber insulated and sheathed drum reeling cables with an extruded screen, reduced weight and dimension for use on one way reels with an operation speed of 200m/min, two way reels with an operation speed of 200m/min, end rollers with an operation speed of 180m/min and central cable rollers with an operation speed of 60m/min. Operational temperature in ambient conditions of -30°C to +80°C

TRATOSGREEN AMP - ES3 A range of medium voltage rubber insulated and sheathed drum reeling cables with reduced halogens and reduced toxicity. The cable also benefits from an extruded screen, reduced weight and dimension; it is suitable for use on one way reels with an operation speed of 200m/min, two way reels with an operation speed of 200m/min, end rollers with an operation speed of 180m/min and central cable rollers with an operation speed of 60m/min. Operational temperature in ambient conditions of -30°C to +80°C.

10

Marine Cables

Power Medium Voltage

TRATOS MARINE AMV® - 3,6/6 kV (Umax = 7,2KV) TRATOS MARINE AMV® - 6/10 kV (Umax = 12KV) TRATOS MARINE AMV® - 8,7/15 kV (Umax = 17,5KV)

Construction:

Tinned copper conductorSemiconducting layerHF-HEPR insulation or HF-XLPESemiconducting layerCopper tape shieldExtruded filler halogen freeSynthetic tapeInner covering SHF1Tinned copper braid armourOuter sheath SHF1

Standards:

Design guideline EC 60092-354; IEC 60092-350Flame retardance IEC 60332 3A; IEC 60332-1Halogen free IEC 60754-1 and 2Smoke emission IEC 61034-1 and 2

11

Marine Cables

Unarmoured power and control cables

TRATOS MARINE - U® - (Unarmoured) 0,6/1kV TRATOS MARINE - FU® - (Flexible conductor Unarmoured) 0,6/1kV

Single core cable, two, three and multicores cables.

Standards:

IEC 60092350-353 Design guideIEC 60092351;-359 MaterialsIEC 60331 Fire resistanceIEC 60332-1; 60332-3A Flame retardanceIEC 754-1,…-2 Halogen free propertiesIEC 61034-1,…-2 Smoke emission

Suitable applications: installation on board, ship, navy.

Construction:

1 Plain (tinned when request) annealed copper cl. 2 acc. to IEC 60228.2 HFXLPE4 insulation3 Halogen free compound for cables ≥35 mm² filler (if required)4 SHF1 over-sheath

12

Marine Cables

Armoured power and control cables

TRATOS MARINE - A® - (Armoured) 0,6/1kV

TRATOS MARINE - FA® - (Flexible conductor Armoured) 0,6/1kV Single core cable, two, three and multicores cables.

Standards:

IEC 60092350-353 Design guideIEC 60092351;-359 MaterialsIEC 60331 Fire resistanceIEC 60332-1; 60332-3A Flame retardanceIEC 754-1,…-2 Halogen free propertiesIEC 61034-1,…-2 Smoke emission

Suitable applications: installation on board, ship, navy.

Construction:

1 Plain (tinned when request) annealed copper cl. 2 acc. to IEC 60228. (cl.5 when request) acc. to IEC 602282 HFXLPE4 insulation3 Synthetic tape or halogen free compound4 Plain copper wires5 Halogen free compound for cables ≥35 mm² filler (if required)6 SHF1 oversheath

13

Marine Cables

Fire resistant unarmoured power and control cables

TRATOS MARINE - UFR® - (Unarmoured Fire Resistant) 0,6/1kV TRATOS MARINE - FUFR® - (Flexible conductor Unarmoured FireResistant) 0,6/1kVSingle core cable, two, three and multicores cables.

Standards:

EC 60092350-353 Design guideIEC 60092351;-359 MaterialsIEC 60331 Fire resistanceIEC 60332-1; 60332-3A Flame retardanceIEC 754-1,…-2 Halogen free propertiesIEC 61034-1,…-2 Smoke emission

Suitable applications: installation on board, ship, navy.

Construction:

1 Plain (tinned when request) annealed copper cl. 2 acc. to IEC 60228.2 MICA TAPE and HFXLPE4 insulation3 Halogen free compound for cables ≥35 mm² filler (if required)4 SHF1 oversheath

14

Marine Cables

Fire resistant armoured power and control cables

TRATOS MARINE - AFR® (Armoured Fire Resistant) 0,6/1kV TRATOS MARINE - FAFR® (Flexible conductor Armoured Fire Resistant) 0,6/1kV

Single core cable, two, three and multicores cables.

Standards:

IEC 60092350-353 Design guideIEC 60092351;-359 MaterialsIEC 60331 Fire resistanceIEC 60332-1; 60332-3A Flame retardanceIEC 754-1,…-2 Halogen free propertiesIEC 61034-1,…-2 Smoke emission

Suitable applications: installation on board, ship, navy

Construction:

1 Plain (tinned when request) annealed copper cl. 2 acc. to IEC 60228. (cl.5 when request) acc. to IEC 602282 Mica tape and HFXLPE4 insulation3 Synthetic tape or halogen free compound4 Plain copper wires5 Halogen free compound for cables ≥35 mm² filler (if required)6 SHF1 oversheath

15

Marine Cables

Telecomunications and Instrumentation Cables

TRATOS MARINE - UCS® (Unarmoured Collective Screen) 300/500 V

Standards:IEC 60092-3; 375 Design guidelineIEC 60092351; -359 MaterialsIEC 60332-1, 60332-3A Flame retardanceIEC 60754-1, …2 Halogen free propertiesIEC 61034-1, …2 Low smoke emission

Construction:1 Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 602282 Insulation: HF XLPE3 Lay up: Assembled pairs/ triples/ quads4 Shield: Aluminium/ polyestere tape with drain wire stranded tinned copper5 Sheath: SHF1

16

Marine Cables

Telecomunications and Instrumentation CablesTRATOS MARINE - UIS® (Unarmoured Individual Screen) 300/500V

TRATOS MARINE - UICS® (Unarmoured Individual & Collective Screen) 300/500V

Standards:IEC 60092-3; 375 Design guidelineIEC 60092351; -359 MaterialsIEC 60332-1, 60332-3A Flame retardanceIEC 60754-1, …2 Halogen free propertiesIEC 61034-1, …2 Low smoke emission

Construction:1 Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 602282 Insulation: HF XLPE3 Lay up: Assembled pairs/ triples/ quads4 Shield: Indiv. or indiv & collective alum/ polyester tape with drain wire stranded tinned copper5 Sheath: SHF1

17

Marine Cables

Telecomunications and Instrumentation CablesTRATOS MARINE - ACS® (Armoured Collective Screen) 300/500 V

Standards:IEC 60092-3; 375 Design guidelineIEC 60092351; -359 MaterialsIEC 60332-1, 60332-3A Flame retardanceIEC 60754-1, …2 Halogen free propertiesIEC 61034-1, …2 Low smoke emission

Construction:1 Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 602282 Insulation: HF XLPE3 Lay up: Assembled pairs/ triples/ quads4 Shield: Aluminium/ polyester tape with drain wire stranded tinner copper5 Inner covering: Syntetic tape6 Braid: Plain copper7 Sheath: SHF1

18

Marine Cables

Telecomunications and Instrumentation CablesTRATOS MARINE - AIS® (Armoured Individual Screen) 300/500 V

TRATOS MARINE - AICS® (Armoured Individual & Collective Screen) 300/500 V

Standards:IEC 60092-3; 375 Design guidelineIEC 60092351; -359 MaterialsIEC 60332-1, 60332-3A Flame retardanceIEC 60754-1, …2 Halogen free propertiesIEC 61034-1, …2 Low smoke emission

Construction:1 Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 602282 Insulation: HF XLPE3 Lay up: Assembled pairs/ triples/ quads4 Shield: Indiv. or indiv & collective aluminium/ polyester tape with drain wire stranded tinned copper5 Inner covering: Syntetic tape6 Braid: Plain copper7 Sheath: SHF1

19

Marine Cables

Telecomunications and Instrumentation CablesTRATOS MARINE - ACS - FR® (Armoured Collectively Screen-Fire Resistant) 300/500 V

Standards:IEC 60092-3; 375 Design guidelineIEC 60092351; -359 MaterialsIEC 60332-1, 60332-3A Flame retardanceIEC 60754-1, …2 Halogen free propertiesIEC 61034-1, …2 Low smoke emissionIEC 60331 Fire resistance

Construction:1 Conductor: Plain (tinned when request) annealed copper cl. 2 (cl.5 when request) acc. to IEC 602282 Insulation: Mica tape and HF XLPE3 Lay up: Assembled pairs/ triples/ quads4 Shield: Aluminium/ polyestere tape with stranded tinned copper wire drain wire5 Inner covering: Syntetic tape or halogen free compound when necessary6 Braid: Plain copper7 Sheath: SHF1

20

Tratos on demandCables Tailor Made

Our “Cables Tailor Made" service can offer custom design and built solutions to the most demanding of circumstances. In conjunction with our clients Tratos can offer you:

• Variety of lengths

• Large overall diameter (above standard products)

• Cable designs

• Bespoke cables

• Environmentally specific cables (mud, chemicals, UV, water, oil, radiation)

Case StudyTratos has manufactured and supplied Superconducting conductors to ITER (International Thermonuclear Experimental Reactor), an international nuclear fusion research and engineering project, which is currently building the world's largest experimental tokamak nuclear fusion reactor at the Cadarache facility in the south of France. www.iter.org

Tratos GroupCables for a moving world

www.tratos.eu