JA Solar Full Square Smart Module Mono (SE) · 2015. 8. 19. · 0 5 10 15 20 25 30 35 40 Voltage...

4
www.jasolar.com JAM6(SE)(BK)(R) 60/260-280 Harvest The Sunshine Premium Cells, Premium Modules Smart Module 100% Communication 20% More Energy

Transcript of JA Solar Full Square Smart Module Mono (SE) · 2015. 8. 19. · 0 5 10 15 20 25 30 35 40 Voltage...

Page 1: JA Solar Full Square Smart Module Mono (SE) · 2015. 8. 19. · 0 5 10 15 20 25 30 35 40 Voltage (V) Power-Voltage Curve (JAM6(SE)(BK)(R) 60-270) Power (W) 0 50 100 150 200 250 300

www.jasolar.com

JAM6(SE)(BK)(R) 60/260-280

Harvest The SunshinePremium Cells, Premium Modules

Smart Module100% Communication20% More Energy

Page 2: JA Solar Full Square Smart Module Mono (SE) · 2015. 8. 19. · 0 5 10 15 20 25 30 35 40 Voltage (V) Power-Voltage Curve (JAM6(SE)(BK)(R) 60-270) Power (W) 0 50 100 150 200 250 300

Key Features

Maximum energy gain ground mounted system: 2-5%,

commercial 2-10%, residential 2-25%

15.90%

Monocrystalline modules designed for residential commercial and

utility applications, rooftop or ground mount

Excellent mechanical load resistance: Certified to withstand

high wind loads (2400Pa) and snow loads (5400Pa)5400Pa

BL

AC

K

Automatic module shut-down Unique electrocution prevention and fire safety

Flexible system design optimal site space utilization at reduced cost

Real-time alerts module-level web monitoring Increased uptime maintenance

Reliable Quality

60/260-280

www.jasolar.comSpecifications subject to technical changes and tests. JA Solar reserves the right of final interpretation.

Comprehensive Certificates

IEC 61215, IEC 61730, MCS and CE

ISO 9001: 2008: Quality management systems

ISO 14001: 2004: Environmental management systems

BS OHSAS 18001: 2007: Occupational health and safety management systems

Environmental policy: The first solar company in China to complete Intertek's carbon footprint evaluation program and receive green leaf mark verification for our products

Positive power tolerance: 0~+5W

100% EL double-inspection ensures modules are defects free

Potential Induced Degradation (PID) Resistant

FULL SQUARE MONOCRYSTALLINE SILICON MODULE

JAM6(SE)(BK)(R)

Product Warranty10-year product warranty25-year linear power warranty

JA Solar Holdings Co., Ltd.

1 5 10 15 20 25Year

Added Value From Warranty100%97%

90%

80%

JA Solar Holdings Co.,Ltd is a world leading manufacturer of high-performance solar power products that convert sunlight into electricity for residential, commercial and utility-scale power generation. The company was founded in May 2005 and publicly listed on NASDAQ in February 2007. JA Solar has been the world's leading cell producer since 2010, and has firmly established itself as a tier 1 module supplier since 2012. Capitalizing on our strength in solar cell technology, we are committed to provide modules with unparalleled conversion efficiency, yield efficiency, and reliability to enable you to maximize your returns on PV projects. With its leading industry experience, continuous effort on R&D, customer-oriented service and sound financial status, JA Solar is your best choice of long-term trustworthy partner.

Partner Section

Additional Insurance Options

Add : NO.36, Jiang Chang San Road, Zhabei, Shanghai 200436, ChinaTel : +86 21 6095 5888 / +86 21 6095 5999Fax:+86 21 6095 5858 / +86 21 6095 5959Email : [email protected] [email protected]

PowerGuard®

SPECIALTY INSURANCE SERVICES

SOLARSOLAR

I N S U R A N C E & F I N A N C E

Page 3: JA Solar Full Square Smart Module Mono (SE) · 2015. 8. 19. · 0 5 10 15 20 25 30 35 40 Voltage (V) Power-Voltage Curve (JAM6(SE)(BK)(R) 60-270) Power (W) 0 50 100 150 200 250 300

Power Optimizer Inverter

Module embedded

Monitoring Portal

Monitoring Server

AdcVdc

Vdc Safety Output Voltage Per Power Optimizer 1 1**

OUTPUT DURING OPERATION

OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF)

Maximum Output Current Operating Output Voltage

Power Optimizer Connected to a SolarEdge Inverter Power Optimizer connected to a Non-SolarEdge Inverter

155-60

105-VOC of connected PV module

W

W

PV SYSTEM DESIGN

Minimum String Length

Maximum String Length

Maximum Power Per String

Parallel Strings of Different Lengths

Power Optimizer Connected to aNon-SolarEdge Inverter*

According to inverter design rules &PV module datasheet

No

Yes

Power Optimizer Connected to aSolarEdge Inverter

EU

8 (1ph)

16 (3ph)

25 (1ph)

50 (3ph)

* Avallable only if Safety & Monitoring Interface (SMI) is installed or if SafeDCTM is disabled during installation by a one-time operation using the SolarEdge key.

** When SolarEdge Safety & Monitoring Interface (SMI) is installed and off.

5250 (1ph)

11250 (3ph)

Yes

Yes Parallel Strings of Different Orientations

STANDARD COMPLIANCE

Fire Safety

PV Junction Box Safety

PV Junction Box

IEC62109-1 (classⅡsafety TUV-SUD)

EN50548(TUV-SUD)

VDE-AR-E 2100-712:2013-05

Unit

Unit

System ArchitectureJA smart system components work together with any inverter to maximize energy harvest. JA smart modules can communicate by electrical line, allowing

users to monitor system performance in real time.

60/260-280JAM6(SE)(BK)(R)

Page 4: JA Solar Full Square Smart Module Mono (SE) · 2015. 8. 19. · 0 5 10 15 20 25 30 35 40 Voltage (V) Power-Voltage Curve (JAM6(SE)(BK)(R) 60-270) Power (W) 0 50 100 150 200 250 300

MECHANICAL PARAMETERSCell (mm)

Weight (kg)

Dimensions (L×W×H) (mm)

Cable Cross Section Size (mm2)

No. of Cells and Connections

Junction Box

Connector

Packaging Configuration

Full Square Mono 156x156

19.0±0.5

1650x991×40

4

60 (6×10)

Solar edge smart J-Box

MC4 Compatible

26 Per Pallet

Engineering Drawings

WORKING CONDITIONSMaximum System Voltage

Operating Temperature

Maximum Series Fuse

Maximum Static Load, Front (e.g., snow and wind)Maximum Static Load, Back (e.g., wind)

NOCT

Application Class

DC 1000V(TÜV)

-40℃~+85℃

15A

5400Pa (112 Ib/ft2)2400Pa (50 Ib/ft2)

45±2℃

Class A

60/260-280

0 5 10 15 20 25 30 35 40

Voltage (V)

Current-Voltage Curve (JAM6(SE)(BK)(R) 60-270)

Cur

rent

(A)

0 1

2

3

4 5

6

7

8 9

10

1000W/m2

800W/m2

600W/m2

400W/m2

200W/m2

0 5 10 15 20 25 30 35 40

Voltage (V)

Power-Voltage Curve (JAM6(SE)(BK)(R) 60-270)

Pow

er (W

)

0

50

10

0 1

50

200

250

30

0

1000W/m2

800W/m2

600W/m2

400W/m2

200W/m2

0 5 10 15 20 25 30 35 40 45

Voltage (V)

Current-Voltage Curve (JAM6(SE)(BK)(R) 60-270)

Cur

rent

(A)

01

23

45

67

89

10

65℃ 45℃25℃5℃

NOCT

Max Power at STC (Pmax) [W]

Open Circuit Voltage (Voc) [V]

Max Power Voltage (Vmp) [V]

Short Circuit Current (Isc) [A]

Max Power Current (Imp) [A]

TYPE

I-V CURVEELECTRICAL PARAMETERS

TYPE

Rated Maximum Power at STC (W)

Open Circuit Voltage (Voc/V)

Maximum Power Voltage (Vmp/V)

Short Circuit Current (Isc/A)

Maximum Power Current (Imp/A)

Module Efficiency [%]

Power Tolerance (W)

Temperature Coefficient of Isc (αIsc)

Temperature Coefficient of Voc (βVoc)

Temperature Coefficient of Pmax (γPmp)

STC Irradiance 1000W/m2, Module Temperature 25℃, Air Mass 1.5

JAM6(SE)(BK) (R)60-260

JAM6(SE)(BK) (R)60-265

JAM6(SE)(BK) (R)60-270

JAM6(SE)(BK) (R)60-275

JAM6(SE)(BK) (R)60-280

JAM6(SE)(BK) (R)60-260

JAM6(SE)(BK) (R)60-265

JAM6(SE)(BK) (R)60-270

JAM6(SE)(BK) (R)60-275

JAM6(SE)(BK) (R)60-280

Electrical data in this catalog do not refer to a single module and they are not part of the offer. They only serve for comparison among different module types.JA Solar 08.2014

Condition Under Normal Operating Cell Temperature, Irradiance of 800 W/m2 , spectrum AM 1.5, ambient temperature 20℃, wind speed 1 m/s

JAM6(SE)(BK)(R)

204.68

35.46

28.99

7.47

7.06

190.06

34.83

27.91

7.36

6.81

193.72

34.97

28.28

7.39

6.85

197.37

35.09

28.56

7.42

6.91

201.03

35.21

28.88

7.46

6.96

260

38.32

30.49

9.04

8.53

15.90

265

38.52

30.78

9.13

8.61

16.21

-0~+5W

+0.049%/℃

-0.340%/℃

-0.410%/℃

270

38.71

31.08

9.21

8.69

16.51

275

38.89

31.36

9.30

8.77

16.82

280

39.07

31.64

9.39

8.85

17.12

customized cable length available upon request

Grounding holes2 places

Draining Holes8 places

Mounting holes8 places

Junction Box

Label