JA-80JA-80Make your premises an Oasis of security

EN 0611 d2

Page 2: JA-80 Make your premises an Oasis of security EN 0611 d2.

A solution for your security & comfort......

Page 3: JA-80 Make your premises an Oasis of security EN 0611 d2.

Main differences to the JA-63 1. 868MHz radio (up to 2000 meters), no visible antennas, supervision every 9 minutes2. 3V lithium batteries - calculated lifetime 3 years3. LCD keypad with editable texts 4. RFID proximity card reader built into keypads5. 50 addresses to enroll wireless devices (programmable reactions)6. Optional enrollment of devices by entering their production code (bar code)7. 2 hard-wired inputs + inputs in keypads, door detectors and PIR detectors8. Up to 50 users (each can have code, card or both), code management in Comlink 9. 2 levels of partial arming or splitting into 2 sections + 1 common section 10. External keypads for access control11. Totally wire-free outdoor siren 12. Indication of active detectors (open windows or doors)13. Combined wireless movement and glass-break detector 14. Invisible window-detector15. Final-door detector function (garage etc.)16. Annual inspection indication (selectable)17. Summer / Winter time (selectable)18. Smart heating control19. Compatible with CA-1802 and CA-1803 car alarms20. Identical functions for GSM/GPRS and LAN/PSTN communicators21. Separate programming of ARC (Automatic Receiving Center)22. Complies with latest EN and TS standards (grade 2)

Page 4: JA-80 Make your premises an Oasis of security EN 0611 d2.

“LEGO” architecture

Page 5: JA-80 Make your premises an Oasis of security EN 0611 d2.

JK-81JK-81 kit kit

Devices supplied pre-enrolled and pre-programmed

Simple installation

Page 6: JA-80 Make your premises an Oasis of security EN 0611 d2.

JK-81JK-81 consists of: consists of: Control panel with GSM communicator Wireless keypad PIR detector Magnetic detector Indoor siren Key fob Wireless door bell button Proximity card Accessories (batteries etc.)

Page 7: JA-80 Make your premises an Oasis of security EN 0611 d2.

11

55 66

77

Installation in 7 steps Installation in 7 steps

33

44

22

Page 8: JA-80 Make your premises an Oasis of security EN 0611 d2.

Service mode after powering upService mode after powering up

AA:: Enrollment ofEnrollment of more devicesmore devices

• key key 11 and connect batteriesand connect batteries, , exitexit with with ##

BB: Communication quality test: Communication quality test

• keykey 298298 ( (turns on signal measurementturns on signal measurement))

• arrow keys scroll devicesarrow keys scroll devices

• device triggering = signal from 1/4 to 4/4device triggering = signal from 1/4 to 4/4

• # returns you to Service mode # returns you to Service mode

•CC:: GSM signal strength testGSM signal strength test

• keykey 992222

• return to Service mode by #return to Service mode by #

Each signal should be at leastEach signal should be at least 2/4 2/4

Page 9: JA-80 Make your premises an Oasis of security EN 0611 d2.

ProgrammingProgrammingExample:Example:

4 hh mm DD MM YY4 hh mm DD MM YY = = clockclock

220011 Exit delayExit delay 10sec. 10sec.

81 1 777 775 001 81 1 777 775 001 00 = tel. = tel. numbernumber

92619261 = = forward forward SMSSMS

Page 10: JA-80 Make your premises an Oasis of security EN 0611 d2.

299299 enrollment of PGX to AC relay X enrollment of PGX to AC relay X232377 PGX function = on / off PGX function = on / off

Page 11: JA-80 Make your premises an Oasis of security EN 0611 d2.

Handover to the userHandover to the user

Page 12: JA-80 Make your premises an Oasis of security EN 0611 d2.

SET(arm)

UNSET(disarm)

Operating a key-fobOperating a key-fob

Both buttons Both buttons = = PANICPANIC

Page 13: JA-80 Make your premises an Oasis of security EN 0611 d2.

Keypad layoutKeypad layoutAlarm or fault SET A, B and C Power

DetailsSetting (arming)Hot keysA, B & C

PGXOn / Off

Detail reading

Page 14: JA-80 Make your premises an Oasis of security EN 0611 d2.

Let the user feel that (s)he is the masterLet the user feel that (s)he is the master

„Master“ card enrollment: 5 1234 card

Access card enrollment: 6, Master card, key nn, card

Access code programming: 6, Master card, key nn, code

To erase access code and card: 6, Master card, key nn, 0000

nn = user number 01 to 50Each user can have code, card or both

John 2375

Page 15: JA-80 Make your premises an Oasis of security EN 0611 d2.

Keypad operation Keypad operation Card / code Unsetting / Setting

ABC Complete setting

A Partial setting A (if used)

B Partial setting B (if used)

? Status details (open windows, PG, faults)

PGX on

PGX off

# Esc

Function

Page 16: JA-80 Make your premises an Oasis of security EN 0611 d2.

instructionsinstructions 1 ABC arming(=ABC button)

2 A arming(=A button)

3 B arming(=B button)

4 Memory reading

5 Master code / card changing

6 Access code / card programming

7 Operating under duress

8 PGX control (81/80 = on/off or 8 = 2sec. pulse)

9 PGY control (91/90 = on/off or 9 = 2sec. pulse)

0 Service or Maintenance ( 0 service or master code)

Page 17: JA-80 Make your premises an Oasis of security EN 0611 d2.

2 level partial arming

Evening armingGarage….

A

C

BA

KeyKey AAAA A

A

A

B

B

B

C

C

C

KeyKey B BA+BA+B

Key Key ABCABCA+B+CA+B+C

Night armingGround floor + garage

Complete arming

Example: Family house

Page 18: JA-80 Make your premises an Oasis of security EN 0611 d2.

Split systemExample: Two families in a house

Code or cardBush

If both A+B armed,then C also armed

A

C

B

A B

A B

BushARMED

BlairARMED

Entire house armed incl. Common section

Code or cardBlair

C

C

Page 19: JA-80 Make your premises an Oasis of security EN 0611 d2.

Communicator testCommunicator testBoth buttonsBoth buttonsPANIPANICC

Panic alarm SMS

Result:

Function test Knowing the SIM card tel. number

Page 20: JA-80 Make your premises an Oasis of security EN 0611 d2.

Remote access testingRemote access testingPhone keypad authorization: Call and wait for the system to respond (after 5 rings) Enter a valid code (master, user or service) Operate the system - hang up at the end

SMS instructions: „Code space INSTRUCTION“

SET Arming

UNSET Disarming

STATUS Status checking

MEMORY Last event memory checking

PGX ON Turning PGX on

PGX OFF Turning PGX off

PGY ON Turning PGY on

PGY OFF Turning PGX off

AUX ON Turning AUX on

AUX OFF Turning AUX off

CREDIT Prepaid SIM card balance checking

Page 21: JA-80 Make your premises an Oasis of security EN 0611 d2.

Control panel JA-80KFeatures 1: Back up battery 1.3Ah or 2.6Ah Standby consumption 50 mA 2 wired inputs (01 and 02) - programmable Outputs:

EW - external warning (dry contact, max. 1A) IW - internal warning (switches to GND, max. 0.5A) PGX & PGY (switch to GND max. 0.2A) +U power, max. 0.4A

Built in transceiver Optional external antenna Up to 50 wireless devices

Selectable reactions (Natural or others) Assignment to sections (A, B, C) All devices have natural reaction in section C as factory-default Devices can also be enrolled by keying in their production codes

Page 22: JA-80 Make your premises an Oasis of security EN 0611 d2.

Control panel JA-80KHard-wired inputs: Maximum of 5 detectors in a loop, Differentiates between triggering and tampering Programmable reaction (Natural = delayed) Enrollment of a wireless device to address 01 or 02 disables the

input terminal

Max. of 5 detectors in a loop

Page 23: JA-80 Make your premises an Oasis of security EN 0611 d2.

Features 2: Two-level partial setting (A, AB, ABC) Or split system: A, B and C (common section) Devices and codes/cards can have reactions:

Off, Natural, Panic, Fire, 24hr., Next delay, Instant, Set, PG control, Set/Unset Up to 5 final-door detectors Intruder alarm confirmation by a 2nd detector Indication of permanently triggered detectors (details by ? key) Annual inspection request indication option Summer / winter time option Memory for the last 255 events Replaceable memory chip

Can be operated with up to: 50 user codes (locally or remotely by phone or internet) 50 user cards Option: Confirmation of the card by code

Control panel JA-80K

Page 24: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80F keypad

LCD (2x 16 characters) 1st line = status or event 2nd line = name of the event source

Keypad menu - language selection & chime function Hard-wired input IN (Natural reaction = Delayed) Built in proximity card reader Arrow keys allow you to control PGX (= 81 and 80)

A, B & ABC arming hot keys

? Detail reading

Keypad turns off after 20sec (if battery powered) 2 x AA Lithium 3V batteries (3 year lifetime - 2 operations/day)

JA-80E = hard-wired version

Page 25: JA-80 Make your premises an Oasis of security EN 0611 d2.

Keypad text editingIn service mode: Holding ? pressed opens editing Keys:

Arrow – selects the text string to be edited 1 and 7 - scroll through characters (A, B, C…..8,9,0)4 and 5 - move cursor 2 deletes character# exits editing

Comlink SW allows more convenient editing - keypad must be connected to the control panel bus

Page 26: JA-80 Make your premises an Oasis of security EN 0611 d2.

The PC-01 proximity card RFID access card (EM UNIQUE 125kHz)

Up to 50 cards can be enrolled to the system The card has the same function as an access code For higher security the card can be combined with a code PC-02 is a key tag version

Page 27: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80H outdoor keypad Built in RFID reader Connects to the control panel bus via WJ-80 Provides a doorbell button Illuminated keys IP-65 Standby consumption 45 mA

Page 28: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80N outdoor reader RFID card reader Connects to the control panel bus via WJ-80 IP-65 Standby consumption 40 mA

Page 29: JA-80 Make your premises an Oasis of security EN 0611 d2.

The WJ-80 interface Connects outdoor keypad (reader) to the control panel Built-in door bell transmitter Output to operate an electrical door lock (Z8-12V) Open button input Keypad uses Wiegand protocol 26b DIP switches:

1. System keypad / Outdoor bypass switch2. PGY can operate the door lock as well (Y/N)3. Door lock activation time 3 / 6 seconds4. Exit & entrance beeps (Y/N)

Control panel bus

Sequence248 = PGY pulseAuthorized phone opening81 1 777 775 001 790

Page 30: JA-80 Make your premises an Oasis of security EN 0611 d2.

The RC-80 key-fob 2 housings provided (2 or 4 buttons) Key lock (4 buttons only) Can also be used with UC, AC, JA-80L an CA-180x Alkaline battery 6V, life time 2 to 3 years Working range up to 100m

Page 31: JA-80 Make your premises an Oasis of security EN 0611 d2.

The RC-88 button

DIP switches: Panic (remote control or panic button function) TMP (disable tamper sensors and communication supervision)

Can also be used with UC, AC and JA-80L 1x 1/2 AA Lithium 3V battery

(3 year life time, max. 20 activations/day)

Page 32: JA-80 Make your premises an Oasis of security EN 0611 d2.

The RC-89 door bell button Works with the JA-80L indoor siren Can be enrolled to the control panel as a portable panic

button (by keeping pressed for 3 seconds) Can also be used with AC and UC modules No radio communication supervision 6V alkaline battery Working range up to 200m

Mr. Jones

Page 33: JA-80 Make your premises an Oasis of security EN 0611 d2.

The RC-85 remote control module Designed to be installed in a car 3 wires

GND A = if connected to +12V transmits signal B = if connected to +12V transmits signal both A + B connected to +12V transmits a panic signal

Works with the control panel, UC, AC and JA-80L No battery Flashing full-beam headlights or blowing the horn send signals Can also be used to transmit an alarm from a car alarm

Page 34: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80P detector PIR sensor Hard-wired input IN 15 min test mode after closing the cover DIP switches

DEL / INS (natural reaction) NORM / HIGH (immunity level)

Covers 120° / 12m Optional lenses (pet, long corridor, vertical curtain)

1 x AA Lithium battery 3V (3 year life time) 5 min sleep time (can be shortened to 1 minute)

úhel záběru(poh led shora)

2

2,5

1,5

1

0,5

1,6 3,7 12 dosah[m]

výška[m]

Pracovní dosah - pohled z boku

120º

12m

zóna A

zóna B

zóna C

zóna A

zóna Bzóna C

Page 35: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80PB detector PIR sensor + glass-break sensor Enrolls to 2 addresses in the system PIR = identical to JA-80P 15 min test mode after cover closing Glass-break DIP switches

DEL / INS (natural reaction) PIR / GBS (LED indicator function in test mode)

GB detection - up to 9m (can be tested with GBT-212) 2 Lithium 3V batteries: 1 x AA + 1x 1/2 AA

úhel záběru(poh led shora)

2

2,5

1,5

1

0,5

1,6 3,7 12 dosah[m]

výška[m]

Pracovní dosah - pohled z boku

120º

12m

zóna A

zóna B

zóna C

zóna A

zóna Bzóna C

Page 36: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80M detector Magnetic door / window detector Status detector DIP switches:

DEL / INS (natural reaction) MG ON / MG OFF (enables/disables internal sensor)

2 input terminals: TMP = tamper input IN = alarm input

1x 1/2 AA Lithium 3V battery (3 year life time for 20 activations/day)

m ax. 5 m mm

agn

et

LIT

HIU

M3V

1/2

AA

+

kontak tkrytu

externísním ač

reakce

vypnutí m agn. senzoru

M G O FF

M G O N

INS

DEL

Page 37: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80S detector

LITHIUM 3V AA+

Int. S iren

O n

O ff

Reaction

Fire

Instant

Fire detector (optical smoke + temperature over 60°) Test button Jumpers:

FIRE / INS (natural reaction) SIREN ON / OFF (enables / disables internal siren)

1x AA Lithium 3V battery (3 year life time)

Page 38: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80G detector Combustive gas or fume detector Can be tested with a cigarette lighter Jumpers:

10 / 20% LEL (gas concentration) MEM ON / OFF (memory function)

Output relay contact max. 6A Mains powered

Prototypes only

Page 39: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-85P detector Mini-size PIR detector Can be used in a house or in a car (CA-180x) 15 min test mode after closing the cover DIP switches

NORM / HIGH (immunity level) DEL / INS (natural reaction) Supervision ON / OFF Sleep 1 / 5 minutes

Semi-sphere lens max. detection distance 5m Communicating range up to 300 meters 1 x AA Lithium 3V battery

(3 year life time)

Page 40: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-85B detector Mini-size PIR detector Can be used in a house or in a car (CA-1802 or 1803) 15 min test mode after closing the cover DIP switches

DEL / INS (natural reaction) Supervision ON / OFF

Detection up to 9 meters (can be tested with GBT-212) Communicating range up to 300 meters 1 x AA Lithium 3V battery

(3 year life time)

Page 41: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-82M detector Invisible window- (door-) detector To be installed in the frame of a window (door) DIP switches:

Position closed (A or B) INS / DEL TMP on / off Status / pulse reporting

Communicating range up to 300 meters 2 x CR2354 Lithium 3V battery

(3 year life time 5 activations/day)

A

B

Prototypes only

Page 42: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80L indoor siren Generates sounds:

IW alarm Exit and entrance beeps Door bell - 8 melodies Detector-triggered sounds - 8 melodies

LED indicates PGY status Mains powered

Tampering reported if disconnected from the power during an alarm Enrolls by plugging in Two volume levels (selectable by keeping the button pressed) Triple click enables/disables arming chirp sounds

Page 43: JA-80 Make your premises an Oasis of security EN 0611 d2.

siré naa nté na

b a te rie BAT-80

ko nektor b a te rie

50/25 LED O FF/O N

The JA-80A outdoor siren Totally wire-free !!! Loudness increases gradually Max. duration of the siren sound: 3 min. Flashes 30 min. after the alarm Jumpers:

50 / 25 s. (communication cycle with the control panel) LED ON / OFF (warning flash every minute)

Enrolls by connecting its battery Lithium battery BAT-80 (max. life time 3 to 5 years)

Page 44: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80Y communicator Communication via GSM/GPRS GSM gateway function Events reporting by:

SMS and phone calls ARC (IP, SMS or CID protocols) ARC programming can be locked

Remote access via: Phone (keypad registration or SMS) Internet - www.gsmlink.cz Unanswered ringing from an authorized phone

number Remote access possible with a valid code

(UC, MC, SC)

Page 45: JA-80 Make your premises an Oasis of security EN 0611 d2.

Combination of LAN and PSTN enables the same features as GSM/GPRS.

Most of the JA-80V and JA-80Y functions are identical

The JA-80V communicator Communication via LAN & PSTN Events reporting by:

SMS and phone calls ARC (IP, CID or DR protocols) ARC programming can be locked

Remote access via: Phone (keypad registration or SMS) Internet - www.gsmlink.cz Unanswered ringing from an authorized phone

number Remote access possible with a valid code

(UC, MC, SC)

Page 46: JA-80 Make your premises an Oasis of security EN 0611 d2.

INTERNETINTERNET

Central monitoringCentral monitoring

OasisOasis

Telephone networkTelephone network

AutomaticAutomaticReceivingReceivingCenter Center

andandoror

UserUsernotificationnotification

Page 47: JA-80 Make your premises an Oasis of security EN 0611 d2.

Remote accessRemote accesswww.GSMLink.czwww.GSMLink.cz

INTERNETINTERNET

InternetInternet TTelephoneelephone

aandndoror

Page 48: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80X voice communicator Reports alarms with voice messages Up to 4 phone numbers via PSTN 6 voice messages

System name Intrusion Fire Tampering Panic Technical alarm

Allows remote access via telephone keypad authorization

Can be combined with JA-80V or JA-80Y

Prototypes only

Page 49: JA-80 Make your premises an Oasis of security EN 0611 d2.

The SP-02 speaker phone For listening in and talking Can be connected to PSTN or to the phone line

simulated by JA-80Y Answers calls from authorized numbers Half-duplex communication allows a high sensitivity

for listening Push-to-talk feature to call an emergency number 2 x AA alkaline 1.5V battery

Prototypes only

Page 50: JA-80 Make your premises an Oasis of security EN 0611 d2.

The UC-82 relay module Powered by 12V DC 2 output relays (X & Y) - max 2A Low bat. output External antenna is optional Can be used with:

Control panel Detectors RC-8x transmitters

tlačítka

západky

Y

Y

X

X

kon taktkrytu

konekto r externí an tény

RA

DIO

1234

signá lky

no. Reaction Device Enrolls with Max. number

key fob button pressing 1 impulse 1 sec. detector battery connecting

60

key fob button pressing 2 impulse 2 min. detector battery connecting

60

latch key fob button pressing 60 3 tamper detector battery connecting 8

key fob button pressing 60 on / off PG outputs of

control panel entry of 299 in Service mode

1 4

triggering detector battery connecting 8

Page 51: JA-80 Make your premises an Oasis of security EN 0611 d2.

The AC-82 relay module Powered directly from mains 230V, 50Hz 2 output relays (X and Y) - max 5A Can be used with:

Control panel Detectors RC-8x transmitters TP-8x thermostats

no. Reaction Device Enrolls with Max. number

key fob button pressing 1 impulse 1 sec. detector battery connecting

60

key fob button pressing 2 impulse 2 min. detector battery connecting

60

latch key fob button pressing 60 3 tamper detector battery connecting 8

key fob button pressing enrolls pair of buttons

60

PG outputs of control panel

entry of 299 in Service mode

1 on / off

thermostat battery connecting 8

4

triggering detector battery connecting 8

Page 52: JA-80 Make your premises an Oasis of security EN 0611 d2.

The TP-80 thermostat Enrolls to AC-82 Transmits signals:

Temperature below target (normal heating) Below 6°C (anti-freezing) Below 3°C (Freezing alarm - Panic) Above 60°C (Fire alarm) Supervision and battery status

Normal heating can be enabled or disabled in the AC-82 receiver by signals from the control panel (PG), remote controls or detectors

1 AA alkaline battery 1.5V, 1 year lifetime

Page 53: JA-80 Make your premises an Oasis of security EN 0611 d2.

The TP-82 thermostat Enrolls to AC-82 Indicates temperature Transmits signals:

Temperature below target (normal heating) Below 6°C (anti-freezing) Below 3°C (Freezing alarm - panic) Above 60°C (Fire alarm) Supervision and battery status

Normal heating can be enabled or disabled in the AC-82 receiver by signals from the control panel (PG), remote controls or detectors

1 AA alkaline battery 1.5V, 1 year life timeTP-83 weekly temperature programming (2007)

Page 54: JA-80 Make your premises an Oasis of security EN 0611 d2.

Simple heating control

Thermostat AC-82

Radio Cable

Thermostat is enrolled to the AC receiver

Page 55: JA-80 Make your premises an Oasis of security EN 0611 d2.

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Thermostat is enrolled to the AC receiver and also to the control panel

Page 56: JA-80 Make your premises an Oasis of security EN 0611 d2.

Normal heating controlHeating = ON

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Page 57: JA-80 Make your premises an Oasis of security EN 0611 d2.

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Operating heating by remote controlsON = normal heatingOFF = anti-freezing heating only

Page 58: JA-80 Make your premises an Oasis of security EN 0611 d2.

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Operating the heating by keypadON = normal heatingOFF = anti freezing heating only

Page 59: JA-80 Make your premises an Oasis of security EN 0611 d2.

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Operating the heating by a phoneON = normal heatingOFF = anti freezing heating only

Page 60: JA-80 Make your premises an Oasis of security EN 0611 d2.

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Operating the heating by windowsCLOSED = normal heatingOPEN = anti freezing heating only

Page 61: JA-80 Make your premises an Oasis of security EN 0611 d2.

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Robbery ALARM !!!!

Page 62: JA-80 Make your premises an Oasis of security EN 0611 d2.

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Freezing ALARM !!!!(heating is defective)

Page 63: JA-80 Make your premises an Oasis of security EN 0611 d2.

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Fire ALARM !!!!(temperature above 60 °C )

Page 64: JA-80 Make your premises an Oasis of security EN 0611 d2.

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Low battery in thermostat

Page 65: JA-80 Make your premises an Oasis of security EN 0611 d2.

Heating

AC-82

Thermostat

Window detectors Control panelRemote controls

Telephone

Smart heating systemSmart heating system

Communication lost with thermostat

Page 66: JA-80 Make your premises an Oasis of security EN 0611 d2.

““Many useful and intuitive features Many useful and intuitive features are hidden within the system, are hidden within the system, disturbing neither the installer nor disturbing neither the installer nor the end user….”the end user….”

OASiSOASiS brings security and comfort brings security and comfort

Page 67: JA-80 Make your premises an Oasis of security EN 0611 d2.

The UC-8014 multiple channel receiver

Power 230V AC 7 to 28 outputs Extra output for circulation pump Enrolls:

• thermostats• RC controllers • window detectors• control panel PG outputs

Designed for larger heating systems

Page 68: JA-80 Make your premises an Oasis of security EN 0611 d2.

Optional antennasCan be used with:

Control panel UC-82

AN-80

AN-81

Page 69: JA-80 Make your premises an Oasis of security EN 0611 d2.

The JA-80T PC cable Connects control panel to PC Provides USB interface Suitable for Comlink 80 and higher JA-80BT (Bluetooth option - 2007)

Page 70: JA-80 Make your premises an Oasis of security EN 0611 d2.

We would appreciate your comments in:We would appreciate your comments in:http://forum.jablotron.czhttp://forum.jablotron.cz

Your login will be sent by E-mailYour login will be sent by E-mail

Page 71: JA-80 Make your premises an Oasis of security EN 0611 d2.

Comlink 80Comlink 80

Compatible with JA-6x and JA-80