Version 20141021 Page | 1 Infinitybox, LLC | www.infinitybox.com | (847) 232‐1991 J1939 POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview .......................................................................................................................................... 2 Warnings.......................................................................................................................................... 3 J1939 POWERCELL Technical Details ...............................................................................................  4 POWERCELL Installation Steps ........................................................................................................  5 Mounting the POWERCELL ..........................................................................................................  5 Supplying 12volt Power ..............................................................................................................  5 Wiring the Output Harnesses ......................................................................................................  6 Installing Fuses ............................................................................................................................  8 Connecting J1939 CAN Network ..................................................................................................  8 Configuring J1939 Commands from HMI Systems 482CRM ...........................................................  9 Load CANconnect Software .........................................................................................................  9 Install Software for CAN to J1939 Adaptor .................................................................................  9 Setting the J1939 POWERCELL Address ....................................................................................  10 CAN Parameter Setup ................................................................................................................  11 POWERCELL Personality Glossary ..............................................................................................  14 Track ................................................................................................................................................... 14 Toggle ................................................................................................................................................. 14 Pulse Width Modulation (PWM) ............................................................................................. 14 Post‐Time .......................................................................................................................................... 14 Toggle Time ..................................................................................................................................... 15 Track: Pattern ................................................................................................................................. 15 Powering the System .....................................................................................................................  16 Warranty Information ...................................................................................................................  17 

Transcript of J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems...

Page 1: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |1Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

J1939POWERCELLSetupandConfigurationGuideHMISystems482CRMSwitches

TableofContentsOverview .......................................................................................................................................... 2 

Warnings.......................................................................................................................................... 3 

J1939 POWERCELL Technical Details ............................................................................................... 4 

POWERCELL Installation Steps ........................................................................................................ 5 

Mounting the POWERCELL .......................................................................................................... 5 

Supplying 12‐volt Power .............................................................................................................. 5 

Wiring the Output Harnesses ...................................................................................................... 6 

Installing Fuses ............................................................................................................................ 8 

Connecting J1939 CAN Network .................................................................................................. 8 

Configuring J1939 Commands from HMI Systems 482CRM ........................................................... 9 

Load CANconnect Software ......................................................................................................... 9 

Install Software for CAN to J1939 Adaptor ................................................................................. 9 

Setting the J1939 POWERCELL Address .................................................................................... 10 

CAN Parameter Setup ................................................................................................................ 11 

POWERCELL Personality Glossary .............................................................................................. 14 

Track...................................................................................................................................................14 Toggle.................................................................................................................................................14 PulseWidthModulation(PWM).............................................................................................14 Post‐Time..........................................................................................................................................14 ToggleTime.....................................................................................................................................15 Track:Pattern.................................................................................................................................15 

Powering the System ..................................................................................................................... 16 

Warranty Information ................................................................................................................... 17 

Page 2: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |2Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

Overview

TheInfinityboxJ1939POWERCELLbringsflexiblemultiplexedpowerdistributiontoanyvehiclebuilder.UsingstandardJ1939PGNstructuresandcommands,youcancontroltheoutputsonthePOWERCELLwithpracticallyanyJ1939inputdevice.

TheJ1939POWERCELLcomeswithastandardconfigurationthatallowstheend‐userbroadflexibilityincreatingtheirownlayoutstosuittheiruniqueapplications.UsingsimplesoftwaretoolsfromtheirJ1939inputmanufacturer,theycanquicklyconfigurethesysteminthefield.Incaseswherecustomconfigurationsarerequiredforaspecificvehicle,thesystemcanbemodifiedeasily.Contacttechnicalsupportformoredetails.

Page 3: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |3Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

WarningsTHEINFINITYBOXJ1939POWERCELLISAFUSEDPOWERDISTRIBUTIONMODULEFORVEHICLES.PROPERCAREMUSTBETAKENTOFUSETHEINPUTFEEDSTOTHECELLAND THE OUTPUT FEEDS FROM THE CELL. IMPROPER FUSE SELECTION CAN CAUSEDAMAGETOTHEVEHICLEELECTRICALSYSTEMRESULTINGINFIRE.PROPERCAREMUSTBETAKENTOENSURETHATPOWER IS CORRECTLYAPPLIED TOTHEPOWERCELL.REVERSINGPOLARITYTOTHEPOWERANDGROUNDFEEDSWILLCAUSEIRREPARABLEDAMAGETOTHECELLANDWILLVOIDTHEWARRANTY.ADDINGANYELECTRONICSMODULESTOAVEHICLEWILLINCREASETHEDEMANDONTHEBATTERY.CAREMUSTBETAKENTOMAINTAINACHARGEONTHEBATTERYWHENTHEVEHICLESITSIDLEFORPERIODSOFTIME.THISISESPECIALLYIMPORTANTWITHGEL‐CELL AND AGM BATTERIES. WE STRONGLY RECOMMEND INSTALLING A

DISCONNECTSWITCHTHATSEPARATESTHEELECTRICALLOADSINTHEVEHICLEFROM

THEBATTERYWHENNOTINUSE.

Page 4: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |4Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

J1939POWERCELLTechnicalDetailsSystemOperatingVoltage:7.0to15.8VDCNumberofOutputs:10OutputType:High‐SideSwitchedviaMOSFETsMaximumCurrentRatingperOutput:25‐ampsMaximumCurrentRatingperPOWERCELL:125‐ampsInternalFusing:StandardMini™FuseMaximumOperatingTemperature:125°CMinimumOperatingTemperature:‐20°C

Page 5: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |5Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

POWERCELLInstallationSteps

MountingthePOWERCELLMountthePOWERCELLonasuitableflatsurfaceinthevehicle.Usethe4mountingpointsinthecornersofthecelland1/4–inchhardware.TherecommendedmethodtomountthePOWERCELListouse¼‐inchX5/8‐inchshoulderscrews.Ifnotusingshoulderscrews,takecareastonotcrushthemountingpointsbyovertighteningthescrews.Inapplicationswherethesteady‐statecurrentdrawoutofthePOWERCELLexceeds90‐amps,mountthePOWERCELLinanareawithadequateventilationandwiththefinsoftheheatsinkrunningvertically.

Supplying12‐voltPowerThePOWERCELLgetsits12‐voltpowerfromthe3circularMaxi‐styleconnectorsontheedgeofthecell.Eachoftheseconnectorscanacceptupto60‐amps.Thefollowingtablesummarizesallofthecomponentsfortheseconnectors.ThePOWERCELLinputconnectorsusereadilyavailableconnectorcomponentsfromDelphi.SeetheinstructionsfromDelphiforproperassemblyandterminationoftheseconnectorcomponents.BasedonthetotalcurrentoutputofthePOWERCELLrequired,install1or2powerfeedsintotheroundMaxi‐styleconnectors.SealthethirdremainingconnectorwithanPOWERCELLsealingplug.Table1:POWERCELLInputConnectorComponents.

DelphiPartNumber

POWERCELL

Input

Connector

Connector 12129380Seal 12129382TPA 12129384WireSeal 12129381Terminal 12129414

EachofthepowerfeedwirestothePOWERCELLshouldbeprotectedwithafuselocatedascloselytothebatterysourceaspossible.SizethefusebasedonthegaugeofwirefeedingthePOWERCELL.TheTable2summarizestheproperfusesizesfordifferentwires.

Page 6: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |6Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

Table2:MaximumFuseRatingsforDifferentWireGauges.

AWGSize MaximumFuseRating(Amps)12 4010 508 60

WiringtheOutputHarnessesThePOWERCELLoutputconnectorsusereadilyavailableconnectorcomponentsfromDelphi.SeetheinstructionsfromDelphiforproperassemblyandterminationoftheseconnectorcomponents.Table3summarizesalloftheconnectorandterminalcomponentsrequiredtobuildcustomwiringharnessesforyourJ1939POWERCELL.Table3:POWERCELLOutputConnectorComponents.

DelphiPartNumber

POWERCELL

Output

Connector

Connector/Seal 12110295

TPA 12059195

WireSeal 12015323

Terminal 12129493

Eachoutputharnesshasonegroundwireand5outputwires.Thegroundwiresshouldbe14‐AWGandshouldbeconnectedtothevehicleground.ItisimportantthatthePOWERCELLisgroundedtothechassisthroughametal‐to‐metalconnection.Makesuretoremoveallpaint,powdercoating,dirtandgreasefromthecontactarea.Theindividualoutputwiresshouldbeproperlysizedtocarrytheoutputload.ThemaximumoutputcurrentforasinglePOWERCELLoutputis25‐amps.ThetotalPOWERCELLcancarryupto125‐amps.Exceedingthesevalueswilldamagethecellandvoidthewarranty.

Page 7: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |7Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

Table4summarizesthedetailsoftheoutputharnessesbyconnectorandcavityidentification.Table4:POWERCELLOutputHarnessConnectorDetails.CavityID ConnectorA ConnectorBA GROUND GROUNDB Output10 Output1C Output9 Output2D Output8 Output3E Output7 Output4F Output6 Output5Figure1identifiesalloftheconnectorsontheJ1939POWERCELL.

Figure1:SocketIdentificationforJ1939POWERCELL.

Page 8: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |8Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

InstallingFusesThePOWERCELLhasinternalfuseholderstoprotecttheoutputwiresfromshortcircuitsandlow‐overloads.TheholdersaredesignedforastandardMini™automotivefuse.Selecttheratingoffusetoprotectthesmallestgaugeofwireintheharnessforeachoutput.Neveruseafuseratedathigherthan25‐ampstoprotectaPOWERCELLoutput.Table5givesrecommendationsonfuseratingsfordifferentwiregauges.Table5:MaximumFuseRatingsforDifferentWireGauges.

AWGSize MaximumFuseRating(Amps)20 1018 1516 2014 25

UseonlyOEMapprovedMini™fusestoprotectthePOWERCELLoutputs.Therearenumerousgrey‐marketmanufacturersoffusesthatareunsafeandunreliable.RecommendedmanufacturersforthesefusesareLittelfuse,Inc,BussmannandPacificEngineering.

ConnectingJ1939CANNetworkTheCANsocketsontheJ1939POWERCELLsconnecttheJ1939inputdevicetothecells.Thesesocketsprovide12‐voltpowerfortheJ1939inputdeviceandtheCANHI&LOWconnectionfortheJ1939network.TherearetwoCANsocketsonthePOWERCELLsothatmultipleJ1939POWERCELLsandJ1939inMOTIONCellscanbeconnectedonthesamenetwork.AnCANterminatorplugwitha120‐ohmresistorshouldbeinsertedintothelastopenCANsocketontheJ1939network.ThetwoCANsocketsonaPOWERCELLareelectricallyidenticalsoyoucanplugtheCANconnectorintoeithersocket.Table6showsthefunction,cavityidentificationandwirecolorsfortheCANconnector.ConnectthecorrespondingwiresfromtheJ1939inputdevicetothesecavitiesintheconnector.

Page 9: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |9Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

Table6:CANConnectorWiringDetails.

CavityID Function StandardWireColor5 Ground Black6 CANLOW Green7 CANHIGH Yellow8 +12VoltPower Red

WhenbuildingtheJ1939networkbetweenthecells,the+12VoltPowerwiresandtheGroundwiresshouldonlygobetweenthefirstPOWERCELLandtheJ1939inputdevice.ThereshouldnotbepowerandgroundwiresbetweenthedifferentJ1939cellsinthenetwork.TheJ1939POWERCELLcansupplyatotalof0.6‐ampsoutonthe+12VoltPowerwireintheconnectorsocket.IfthetotalcurrentdrawfortheJ1939inputdevicesexceedsthislimit,theymustbeconnectedto+12voltsfromadifferentsource.

ConfiguringJ1939CommandsfromHMISystems482CRM

LoadCANconnectSoftwareFollowtheinstructionssuppliedwiththeHMISystemsCANconnectSoftwareforproperinstallation.Moreinformationcanbefoundatwww.hmisystems.net.

InstallSoftwareforCANtoJ1939AdaptorFollowtheinstallationinstructionssuppliedwithyourJ1939toUSBadaptor.

Page 10: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |10Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

SettingtheJ1939POWERCELLAddressEachJ1939POWERCELLorJ1939inMOTIONCellmusthaveitsownuniqueaddressforthenetworktoworkcorrectly.TheaddressissetbyarrangingjumpersinabinarypatternunderthecoverofthePOWERCELL.Figure2showsthelocationoftheaddressheadersonthePOWERCELL.

Figure2:LocationoftheAddressHeadersontheJ1939POWERCELL.

Page 11: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |11Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

Figure3showshowtoproperlyorientthejumpersontheheaderstosetthecelladdress.

Figure3:CorrectOrientationoftheAddressHeaders.

CANParameterSetupForPGN’sintherangeofFF00throughFF0F,thefirst60ofthe64bitsintheavailable8bytescorrespondtooutputsonthecellsattachedtotheJ1939network.A(1)inanyofthesebitswillcauseitscorrespondingcelloutputtoreactbasedonitsconfigurationtable.OnoneJ1939network,therecanbetwodifferentgroupsofJ1939inputdevicesassignedtoPGN’sFF00throughFF0F.J1939inputdevicesinGroup1canbeassignedPGN’sFF00throughFF07andcancontrolPOWERCELLorinMOTIONcellsaddressedatA1,A2orA3..J1939inputdevicesinGroup2canbeassignedPGN’sFF08throughFF0FandcancontrolPOWERCELLorinMOTIONcellsaddressedatA4,A5orA6.SwitchesassignedtoGroup1cannotcontrolcellsassignedinGroup2.SwitchesinGroup2cannotcontrolcellsassignedinGroup1.SeeFigure4formoredetails.

Page 12: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |12Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

Figure4:Groups,PGN’sandCellAddressesforJ1939Network.Table7summarizesthecontrolbits,theassignedpersonalitiesandthedetailsforeachoutputintheGroup1cells.Table7:ControlBitDetailsforGroup1Outputs.

7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

Cell Address 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 1 1

Cell Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2

Connector B B B B B A A A A A B B B B B A A A A A B B B B B A A A A A B B

Cavity ID B C D E F F E D C B B C D E F F E D C B B C D E F F E D C B B C

Personality

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Toggle

Toggle

7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

Cell Address 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 2 2 X X X X

Cell Output 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 6 7 8 9 10 9 10 X X X X

Connector B B B A A A A A B B B B B A A A A A B B B A A A A A A A X X X X

Cavity ID D E F F E D C B B C D E F F E D C B B C D E F F E D C B X X X X

Personality

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Track: PWM 50%

Track: PWM 50%

Track: PWM 50%

Post Time: 30 Sec.

Post Time: 60 Sec.

Toggle Time: 30 Sec.

Track: Pattern

Track: Pattern

Track: Pattern

Track: Pattern

X X X X

Byte 5 Byte 6 Byte 7 Byte 8

Byte 1 Byte 2 Byte 3 Byte 4

Page 13: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |13Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

Table8summarizesthecontrolbits,theassignedpersonalitiesandthedetailsforeachoutputintheGroup2cells.Table8:ControlBitDetailsforGroup2Outputs.

7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

Cell Address 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 6 6 4 4

Cell Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2

Connector B B B B B A A A A A B B B B B A A A A A B B B B B A A A A A B B

Cavity ID B C D E F F E D C B B C D E F F E D C B B C D E F F E D C B B C

Personality

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Track

Toggle

Toggle

7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

Cell Address 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 5 4 4 4 4 4 4 4 4 5 5 X X X X

Cell Output 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 6 7 8 9 10 9 10 X X X X

Connector B B B A A A A A B B B B B A A A A A B B B A A A A A A A X X X X

Cavity ID D E F F E D C B B C D E F F E D C B B C D E F F E D C B X X X X

Personality

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Toggle

Track: PWM 50%

Track: PWM 50%

Track: PWM 50%

Post Time: 30 Sec.

Post Time: 60 Sec.

Toggle Time: 30 Sec.

Track: Pattern

Track: Pattern

Track: Pattern

Track: Pattern

X X X X

Byte 5 Byte 6 Byte 7 Byte 8

Byte 1 Byte 2 Byte 3 Byte 4

Page 14: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |14Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

POWERCELLPersonalityGlossaryTheJ1939POWERCELLhasapre‐configuredlibraryofpersonalitiesthatdefinehowtheoutputreactswhenitreceivesaJ1939command.Thefollowinglistdescribesthesedifferentpersonalitiesandtheirbehaviors.

TrackTrackisthemostbasicpersonality.Theoutputtracksthestateoftheinput.WhentheJ1939switchispressedorlatchedintoanONposition,itisbroadcastinganONcommandtothePOWERCELLoutput.ThatoutputwillremainONaslongastheJ1939inputdeviceisbroadcastingtheONcommand.WhentheJ1939inputdevicebroadcastsanOFFcommand,thePOWERCELLoutputturnsOFF.

ToggleThetogglepersonalitylatchesthestateofthePOWERCELLoutputineitheranONorOFFstatebasedonreceivingacommandfromtheJ1939inputdevice.TheJ1939inputdevicebroadcastsacommandindicatingthatthestateoftheswitchhaschangedfromOFFtoONandbacktoOFFagain.ThisactioncausesthePOWERCELLtochangethestateoftheoutputfromOFFtoONorONtoOFF.ThisistobeusedwithJ1939inputsdevicesthathaveamomentarymechanicalactionandbroadcastachangeinswitchstateinthepressedpositionoftheswitch.

PulseWidthModulation(PWM)ThePoweroutputsarecontrolledbysolid‐stateMOSFETs.ThisallowsthePOWERCELLtovarytheamountofpowercomingoutofanoutputbypulsingtheoutputrapidly.Thisallowsforeasycontroloflightdimming,heatercontrolandmotorspeed.ThedefaultPWMdutycycleforaJ1939POWERCELLoutputis50%.ThebasefrequencyofthePWMpulseis200Hz.Customdutycyclesandbasefrequenciesareavailable.Contacttechnicalsupportformoreinformation.NOTE:PulseWidthModulationofinductiveloadswillrequireaquenchingdiodetosuppressanyback‐EMF.Consultthemanufacturerofyourloadformoreinformation.FailuretoinstallquenchingdiodeswillresultindamagetothePOWERCELLoutputandvoidthewarrantyofthecell.

Post‐Time

Page 15: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |15Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

APostTimeoutputisaTrackoutputwithdelaybuiltintoit.TheoutputturnsONwiththeJ1939input.WhentheJ1939inputturnsOFF,thePOWERCELLoutputremainsONforapresetperiodoftime.Thestandardconfigurationhasoptionsfor30and60seconds.Customtimingisavailable.Contacttechnicalsupportformoreinformation.

ToggleTimeToggleTimesetsatimeronthePOWERCELLoutputbasedonamomentaryinputfromtheJ1939inputdevice.AmomentarypressoftheinputswitchwillcausethePOWERCELLoutputtoturnONforapresetperiodoftime.ThePOWERCELLoutputwillturnOFFafterthispresetperiodoftimeregardlessforhowlongtheJ1939inputswitchispressed.Thestandardtimervalueis30secondsfromthepressoftheJ1939inputswitch.Customtimingisavailable.Contacttechnicalsupportformoreinformation.

Track:PatternTrackPatternisatrackingpersonalitythatgeneratesapatternapproximatingavehicleturn‐signal.ThePOWERCELLoutputwillturnONandOFFatarateofapproximatelyonecycleper2seconds.Theduty‐cycleofthepatternisapproximately50%.Custompatternsareavailable.Contacttechnicalsupportformoreinformation.

Page 16: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |16Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

PoweringtheSystemOncetheJ1939inputdevicesareproperlysetupandconfigured,connectthenetworkto+12voltsthroughtheinputharnessestothecells.After3seconds,thesystemwillbecommunicatingwiththeJ1939inputdevices.ThereisablueLEDlocatedtowardsthecenterofthePOWERCELLundertheclearcover.Thislightindicatesthestatusofthecommunicationonthenetwork.Whenthesystemisproperlyconnectedandcommunicating,thelightshouldblinkattherateestablishedontheHMIswitchpanel.ThelightwillalsoflashwhenitreceivesaswitchcommandfromoneoftheJ1939inputdevicesonthenetwork.IftheblueLEDturnsonandstaysonafterpowerisappliedtothesystem,checktheconnectorsintheJ1939networkorchecktomakesurethatthe120‐Ohmterminatorresistorisproperlyinstalledinthenetwork.AsteadybluelightindicatesthatthePOWERCELLprocessorisoperatingbutthereisnocommunicationontheJ1939network.IftheblueLEDdoesnotilluminateatall,checktomakesurethatyouaregettingpowertothePOWERCELL.

Page 17: J1939 POWERCELL and Configuration Guide HMI … POWERCELL Setup and Configuration Guide HMI Systems 482CRM Switches Table of Contents Overview ...

Version20141021 P a g e |17Infinitybox,LLC|www.infinitybox.com|(847)232‐1991

WarrantyInformationInfinitybox,LLC(“Infinitybox”)warrantsagainstanydefectsinmaterialsandworkmanshiptotheProduct’smodules,wiringharnessesandaccessorymodulesforaperiodofone(1)yearfromthefirstdateofpurchase.Subjecttothetermsofthiswarrantydescribedbelow,InfinityboxwillreplaceanysuchdefectiveProductthatisreturnedtoInfinityboxwithintheone(1)yearperiodfrominitialpurchase.ReplacementofanydefectivepartorProductwillnotextendtheapplicablewarrantyperiod.Thewarrantydoesnotapplyto:(i)anyProductthatisnotinstalledincompliancewiththeapplicableProductdocumentation;(ii)anydefectin,orfailureof,theProductresultingfromanaccident,shock,negligence,waterimmersionormisuse;(iii)anyProductthathasbeenmodified,adjusted,repaired,ordisassembledbyanypartyotherthanInfinitybox;or(iv)anydefectotherthaninmaterialsandworkmanship.ThiswarrantycoversonlytheoriginalpurchaserofProductpurchasedfromanInfinityboxauthorizeddealerintheUnitedStates.Inordertoreceivewarrantyservice,purchasermustprovideInfinityboxwithacopyofthereceiptstatingthedealername,productpurchasedanddateofpurchase.Productsfoundtobedefectiveduringthewarrantyperiodwillbereplaced(withaproductdeemedtobeequivalentorbetter)atthediscretionofInfinitybox.Infinitybox’ssoleliabilityforanydefectiveProductislimitedsolelytothereplacementofProductpursuanttothiswarranty.Infinityboxreservestherighttoreplaceanyrepairablepartswithneworrefurbishedparts.INFINITYBOXDISCLAIMSALLOTHERWARRANTIES,WHETHEREXPRESS,IMPLIEDORSTATUTORY,SUCHASWARRANTIESOFMERCHANTABILITYANDFITNESSFORPURPOSE.INNOEVENTSHALLINFINITYBOXBELIABLEFORANYPUNITIVE,INDIRECT,INCIDENTALORCONSEQUENTIALDAMAGES,INCLUDINGWITHOUTLIMITATION,LIABILITYFORLOSSOFUSE,LOSSOFPROFITS,LOSSOFPRODUCTORBUSINESSINTERRUPTIONHOWEVERTHESAMEMAYBECAUSED,INCLUDINGNEGLIGENCE.