ITB 2013-059 -BOQ.xlsx

40
Electronic copy of the BOQ shall be submitted along with the signed hard copy thereof. In case of any discrepancy between the soft and the hard copies, the hard copy shall prevail. ITB 2013- 059 PAL 10-83499 /Renewable Energy Generation through Solar Panels for Public Education, Health and Water Facilities in the Gaza Strip. PRICE SCHEDULE (Bill of Quantities)

Transcript of ITB 2013-059 -BOQ.xlsx

Page 1: ITB 2013-059 -BOQ.xlsx

Electronic copy of the BOQ shall be submitted along with the signed hard copy thereof. In case of any discrepancy between the soft and the hard copies, the hard copy shall prevail.

ITB 2013- 059PAL 10-83499 /Renewable Energy Generation through Solar Panels for Public Education, Health

and Water Facilities in the Gaza Strip.

PRICE SCHEDULE (Bill of Quantities)

rami.rishmawi
Typewritten Text
rami.rishmawi
Typewritten Text
rami.rishmawi
Typewritten Text
rami.rishmawi
Typewritten Text
rami.rishmawi
Typewritten Text
Revised Bill of Quantities (BoQ)
Page 2: ITB 2013-059 -BOQ.xlsx

PREAMBLE

1 .The contractor must provide a detailed cost breakdown for each item.

2.The contractor must provide Technical descriptions for each proposed item and sufficient detail to allow UNDP todetermine compliance of Bid with specifications as per Schedule of Requirements and Technical Specifications of this ITB.The contractor shall indicate all makes proposed and must attach relevant manufacturer Catalogue/data.

3. All prices/rates quoted must be exclusive of all taxes, since the United Nations, including its subsidiary organs, is exemptfrom taxes.

4. In addition to the hard copy, also provide the information on diskette (IBM compatible).

5. On site trainingUpon completion of the installation, the contractor shall organize an on site training program involving nominatedemployer's staff. Such a program shall be carried out during the commissioning phase. The cost of the training shallbe deemed to have been included in the tendered rates.

6.Contractor's Documents

The contractor's documents must include all construction documentation required for the works. They must include all site information, structural and civil drawings, electrical services drawings at suitable scales showing finaldesign calculations, symbols list, site plan, and single line diagrams for distribution boards, solar switchboards, andcontrol systems.

Operation and Maintenace ManualsThe contractor must subtnit two hard copies on standard sized sheets and two electronic copy in-PDF format of theas built drawings including the wiring diagrams and PV single line diagrams, DC and AC wiring sizing calculationsincluding cross sectional area of the wires used and voltage drop calculations, rating of all fuses and circuitbreakers, operation and maintenance manuals for each different site. The manuals must contain PV systemdescription and catalogues of all PV system components . They shall also contain maintenance schedules, commissioning data , PV system test certificates , a step by step startup and shut down procedure for the entire PVsystem , and description of the type and operation control of the inverter and charge controller.The contractor will maintain monthly visits during the maintenance period to carry out the necessary maintenanceprocesses needed and respond promptly to any emergency needed to keep the system performance intact and perfect.

Page 3: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Bill No (1) PV Solar Cells Project Of Bashir El Rayes School

A

PV Cells WorksThe contractor must submit shopdrawings including any changes and method statement for different construction activities inclusive of all what is needed to complete the job and hand over fully operational PV powered electricity network. The electrical shopdrawings have to be accompanied with final design calculations, symbols list, site plan, and single line diagrams for distribution boards, solar switchboards, and control systems. All junction boxes and DBs will be lockable type.The price includes all builders works, making good and reinstatment including necessary materials and workmanship as well as removal of unwanted materials to dump sites approved by the engineer. In addition, it includes Supplying , installation, commissioning and operation of the PV system as well as maintenance complete with the following requirements:

A.1

Supply, install, connect and operate SUNTECH or equivalent monocrystalline solar module with all mounting structure, necessary electrical cables to connect solar cells together and to the DB's as well as inverters to have a complete operational circuit, Conduits, cable trays,earthing system and complete Main Junction Box( Fuses switch disconnectors, Diodes and others ) according to the engineer's instruction and approval. Price will include all materials needed to connect from modules to inverter and have complete job ready for installing high quality PV modules connected , to achieve minimum 15.6 KWp.The price includes supply and install hot galvanised steel for vertical supports, plates & screws, profiles for steel skeleton including bracing and double hot galvanized angles for dividers. All will be as per drawings, according to the engineer's instruction and approval and price shall include costs of repairing any damaged works. The contractor should provide manufacturer's warrantee for each solar panel for a period not less than 25 ears

Module 60

A.2

Supply, install, connect and operate DC/AC inverter/charger STECA or equivalent. The inverter depending on the system design and installation proposed .The inverter AC nominal power output rating must be equal or greater than the 15 kWp of the PV modules at standard test condition (STC). The inverter unit shall be suitable for indoor and outdoor installations. Cable terminations to inverter shall be of type DC plug and socket connectors. Technical literature has to be provided as generated by the inverters manufacturer software. Inverter shall allow an adjustable power factorOutdoor, minimum AC output power 15 kw, compatible with item (1.1), with all necessary electrical cables, Conduits and trays and all other materials and workmanship needed to connect with the main distribution panel according to the engineer's instruction and approval and have a complete job ready.

Pcs. 1

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Contractor's Signature and  Seal

Page 4: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

A.3

Supply, install, connect and operate deep cycle Batteries (12 V,150AH).GEL cell batteries provided that, deep cycle lead acid batteries (FLA), valve regulated lead acid batteries (VRLA) and Absorbed Glass Mat (AGM). The battery terminal voltage and the AH selected shall be compatible with the charge controller and the inverter selected by the designer of the P V. system. The battery efficiency shall be not less than 85% with lifetime not less than 10 years. The price include the all necessary DC electrical cables, Conduits between batteries and backup system. Also supply and install hot galvanized steel stand with shelves and dividers for hosting the batteries and all other material needed to have a complete job ready according to the engineer's instruction and approval

unit 48

supply, install, connect and operate SMA or equivalent charger controller 15 kW at least 97% efficiency and fast sweep MMPPT Algorithm, high PV input , DC voltage with adjustable current limit. All with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others) as well as all needed protections. The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready.

No. 1

A.4

supply, install, connect and operate SMA or equivalent Backup power 15 kW with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others). The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready (optional item).

No. 1

A.5

Supply & fix galvanized steel protection for a new wall opening size 150x120cm ( the prices shall include the opening in the block, galvanized steel bars, plates and angles, the fixation accessories, painting the steel with one primer coat & two coats of oil paint, all according to the drawings, specification and engineer’s instructions (see dwg) and removal of the unwanted relevant materials to dump site approved by the engineer). The work include making good internal plastering 13 mm thick and external plastering 20mm thick to walls as well as repairing of any damages.

No 1

A.6

Supply, install,connect, test and commission wall mounted exhaust fan of 8" diameter Capacity (250 cfm) At static pressure 60 pascal for the battery room , to be tightly installed complete with all necessary supports, and all required electrical cables and ducts all according engineer’s approval.The price shall include opening duct in the block for the fan,plastering, painting , repair all damages and all other materials needed to have a complete job ready according to the engineer's instruction and approval.

No 1

Contractor's Signature and  Seal

Page 5: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)Total PV CELL

B

Electrical Works:The items in general shall also include conduits, connection boxes, controls, wires, connectors, clamps, bolts, and connecting the cables to switchboards and common electric network are included in the unit price. the main aim of this item is to reconfigure the main distribution board to provide power from the PV system to the lighting system of the school and harmonize the converter with the main distribution board.• Contractor shall submit shop drawings for all electrical works to be approved by the Engineer before executing the work.• As-built drawings shall be submitted after handing over the work.• All the electrical works shall be executed according to Standards, drawings, specifications and supervisor engineer instructions.

B.1

Supply, install and commission main distribution panel board (MDB) size (100x60x30 cm) , one door,as specified and as shown on drawings, factory assembled wired and tested in accordance with international standards, including 2mm galvanized steel frame with antistatic paint, including busbars (160 A) ,neutral bus bar and earthing terminal ,and all necessary civil works for foundations,cable trenches and handing over clean, tested and in operating conditions as GEDCO specifications. (Type is MOELLER or equivalent)

NO 1

B.2

Supply and installation of a manual changeover switch (MTS) 4X40 AMB for plug-and-play between the inverter and the main AC source as drawings and instructions of the supervising engineer ,(Type is Hager, Moller or equivalent).

NO 1

B.3Miniature Circuit Breaker MCB 3X40A. (Type is Moller or equivalent).

NO 2

B.4Miniature Circuit Breaker MCB 3X32A. (Type is Moller or equivalent).

NO 2

B.5AC switch disconnector 3X32A. (Type is Moller or equivalent).

NO 3

B.6Miniature Circuit Breaker MCB 3X25A. (Type is Moller or equivalent).

NO 5

B.7Ditto but residual current circuit breaker RCB 4X40/0.3A. (Type is Moller or equivalent).

NO 1

B.8Digital KWH meter, 3*32 A (ISKRA or equivalent) with all other material needed to have a complete job ready for installing net metering .

NO 3

B.9

B.10Ditto but PVC distribution-board 24 CB capacity, type is GEWISS or equivalent NO

5

B.11Miniature Circuit Breaker MCB 3X25A. (Type is Moller or equivalent). NO

5

B.12 Ditto but MCB 3X16A. (Type is Moller or equivalent). NO 10B.13 Ditto but MCB 2X10A. (Type is Moller or equivalent). NO 25

MAIN DISTRIBUTION BORD (MDB)

Sub-Distribution Boards (SDB) (B1,B2,B3,B4,B5)

Contractor's Signature and  Seal

Page 6: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

B.14Ditto but residual current circuit breaker RCB 4X40/0.03A. (Type is Moller or equivalent). NO

5

B.15

B.16Ditto but PVC distribution-board 24 CB capacity, type is GEWISS or equivalent

NO 4

B.17Ditto but MCB 3X16A. (Type is Moller or equivalent).

NO 4

B.18Ditto but MCB 2X10A. (Type is Moller or equivalent).

NO 24

B.19Ditto but residual current circuit breaker RCB 4X40/0.03A. (Type is Moller or equivalent).

NO 4

B.20

B.21

supplying, connecting, and termination of the following XLPE CU cables with all required electrical and civil works, the item includes dismantling and re install the existing cables and laying under ground PVC piping system, manhols, excavation, warning tapes, backfilling and all required civil works to finish the work according specifications and demands of the supervising engineer, to connect cables terminals from source to destination.The work will include re distribution of all existing loads of the main panel to achive the balance of each phase. According to drawings, specifications, instructions, and demands of the supervising engineer. as follow:

B.22 N2XY-XLPE cable 5*10 mm2 L.S 10

B.23 Flexible Single core copper wire isolated with pvc size 4mm2

L.S 150

B.24 N2XY-XLPE cable 5*6 mm2 L.S 30

Total of WORKS

Sub-Distribution Boards (SDB) (B1/1,B2/1,B3/1,B4/1)

Cables and conduits

Total of ELECTRICAL WORKS

Contractor's Signature and  Seal

Page 7: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Bill No (2) PV Solar Cells Project Of Al Faloga School

PV Cells WorksThe contractor must submit shopdrawings including any changes and method statement for different construction activities inclusive of all what is needed to complete the job and hand over fully operational PV powered electricity network. The electrical shopdrawings have to be accompanied with final design calculations, symbols list, site plan, and single line diagrams for distribution boards, solar switchboards, and control systems. All junction boxes and DBs will be lockable type.The price includes all builders works, making good and reinstatment including necessary materials and workmanship as well as removal of unwanted materials to dump sites approved by the engineer. In addition, it includes Supplying , installation, commissioning and operation of the PV system as well as maintenance complete with the following requirements:

A.1

Supply, install, connect and operate SUNTECH or equivalent monocrystalline solar module with all mounting structure, necessary electrical cables to connect solar cells together and to the DB's as well as inverters to have a complete operational circuit, Conduits, cable trays,earthing system and complete Main Junction Box( Fuses switch disconnectors, Diodes and others ) according to the engineer's instruction and approval. Price will include all materials needed to connect from modules to inverter and have complete job ready for installing high quality PV modules connected , to achieve minimum 10 KWp.The price includes supply and install hot galvanised steel for vertical supports, plates & screws, profiles for steel skeleton including bracing and double hot galvanized angles for dividers. All will be as per drawings, according to the engineer's instruction and approval and price shall include costs of repairing any damaged works. The contractor should provide manufacturer's warrantee for each solar panel for a period not less than 25 years.

Module 40

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Contractor's Signature and  Seal

Page 8: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

A.2

Supply, install, connect and operate DC/Ac Inverter SMA or equivalent. The inverter depending on the system design and installation proposed .The inverter AC nominal power output rating must be equal or greater than the 10kWp of the PV modules at standard test condition (STC). The inverter unit shall be suitable for indoor and outdoor installations. Cable terminations to inverter shall be of type DC plug and socket connectors. Technical literature has to be provided as generated by the inverters manufacturer software. Inverter shall allow an adjustable power factorOutdoor, minimum AC output power 10 kw, compatible with item (1.1), with all necessary electrical cables, Conduits and trays and all other materials and workmanship needed to connect with the main distribution panel according to the engineer's instruction and approval and have a complete job ready.

Pcs. 1

A.3

Supply, install, connect and operate deep cycle Batteries (12 V,150AH).GEL cell batteries provided that, deep cycle lead acid batteries (FLA), valve regulated lead acid batteries (VRLA) and Absorbed Glass Mat (AGM). The battery terminal voltage and the AH selected shall be compatible with the charge controller and the inverter selected by the designer of the P V. system. The battery efficiency shall be not less than 85% with lifetime not less than 10 years. The price include the all necessary DC electrical cables, Conduits between batteries and backup system. Also supply and install hot galvanized steel stand with shelves and dividers for hosting the batteries and all other material needed to have a complete job ready according to the engineer's instruction and approval.

unit 20

A.4

supply, install, connect and operate SMA or equivalent charger controller 10 kW at least 97% efficiency and fast sweep MMPPT Algorithm, high PV input , DC voltage with adjustable current limit. All with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others) as well as all needed protections. The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready.

No. 1

A.5

supply, install, connect and operate SMA or equivalent Backup power 10 kW with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others). The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready (optional item).

No 1

Contractor's Signature and  Seal

Page 9: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

A.6

Supply & fix galvanized steel protection for a new wall opening size 150x120cm ( the prices shall include the opening in the block, galvanized steel bars, plates and angles, the fixation accessories, painting the steel with one primer coat & two coats of oil paint, all according to the drawings, specification and engineer’s instructions (see dwg) and removal of the unwanted relevant materials to dump site approved by the engineer). The work include making good internal plastering 13 mm thick and external plastering 20mm thick to walls as well as repairing of any damages.

No 1

A.7

Supply, install,connect, test and commission wall mounted exhaust fan of 8" diameter Capacity (250 cfm) At static pressure 60 pascal for the battery room , to be tightly installed complete with all necessary supports, and all required electrical cables and ducts all according engineer’s approval.The price shall include opening duct in the block for the fan,plastering, painting , repair all damages and all other materials needed to have a complete job ready according to the engineer's instruction and approval.

No 1

Total of PV Cell

Contractor's Signature and  Seal

Page 10: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)B.14

B.15

supplying, connecting, and termination of the following XLPE CU cables with all required electrical and civil works(duct , trays ,...), the item includes dismantling and re install the existing cables and laying under ground PVC piping system, manhols, excavation, warning tapes, backfilling and all required civil works to finish the work according specifications and demands of the supervising engineer, to connect cables terminals from source to destination.The work will include re distribution of all existing loads of the main panel to achive the balance of each phase. According to drawings, specifications, instructions, and demands of the supervising engineer. as follow:

B.16 N2XY-XLPE cable 5*10 mm2 L.S 10B.17 N2XY-XLPE cable 5*6 mm2 L.S 20

Total of WORKS

Cables and conduits

Total of ELECTRICAL WORKS

Contractor's Signature and  Seal

Page 11: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

B

Electrical Works:The items in general shall also include conduits, connection boxes, controls, wires, connectors, clamps, bolts, and connecting the cables to switchboards and common electric network are included in the unit price. the main aim of this item is to reconfigure the main distribution board to provide power from the PV system to the lighting system of the school and harmonize the converter with the main distribution board.• Contractor shall submit shop drawings for all electrical works to be approved by the Engineer before executing the work.• As-built drawings shall be submitted after handing over the work.• All the electrical works shall be executed according to Standards, drawings, specifications and supervisor engineer instructions.

B.1

Supply, install and commission main distribution panel board (MDB) size (80x60x30 cm) , one door,as specified and as shown on drawings, factory assembled wired and tested in accordance with international standards, including 2mm galvanized steel frame with antistatic paint, including busbars (160 A) ,neutral bus bar and earthing terminal ,and all necessary civil works for foundations,cable trenches and handing over clean, tested and in operating conditions as GEDCO specifications. (Type is MOELLER or equivalent)

NO 1

B.2

Supply and installation of a manual changeover switch (MTS) 4X40 AMB for plug-and-play between the inverter and the main AC source as drawings and instructions of the supervising engineer ,(Type is Hager, Moller or equivalent).

NO 1

B.3Miniature Circuit Breaker MCB 3X40A. (Type is Moller or equivalent).

NO 2

B.4Miniature Circuit Breaker MCB 3X25A. (Type is Moller or equivalent).

NO 3

B.5Ditto but residual current circuit breaker RCB 4X40/0.3A. (Type is Moller or equivalent).

NO 1

B.6Miniature Circuit Breaker MCB 3X32A. (Type is Moller or equivalent).

NO 2

B.7AC switch disconnector 3X32A. (Type is Moller or equivalent).

NO 3

B.8Digital KWH meter, 3*32 A (ISKRA or equivalent) with all other material needed to have a complete job ready for installing net metering .

NO 3

B.9

B.10Ditto but PVC sub distribution-board 24 CB capacity, type is GEWISS or equivalent

NO 3

B.11 Ditto but MCB 3X16A. (Type is Moller or equivalent). NO 3B.12 Ditto but MCB 2X10A. (Type is Moller or equivalent). NO 15

B.13Ditto but residual current circuit breaker RCB 4X40/0.03A. (Type is Moller or equivalent).

NO 3

MAIN DISTRIBUTION BORD (MDB)

Sub-Distribution Boards (SDB) (B1,B2,B3)

Contractor's Signature and  Seal

Page 12: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Bill No (3) PV Solar Cells Project Of A'Aka School

PV Cells WorksThe contractor must submit shopdrawings including any changes and method statement for different construction activities inclusive of all what is needed to complete the job and hand over fully operational PV powered electricity network. The electrical shopdrawings have to be accompanied with final design calculations, symbols list, site plan, and single line diagrams for distribution boards, solar switchboards, and control systems. All junction boxes and DBs will be lockable type.The price includes all builders works, making good and reinstatment including necessary materials and workmanship as well as removal of unwanted materials to dump sites approved by the engineer. In addition, it includes Supplying , installation, commissioning and operation of the PV system as well as maintenance complete with the following requirements:

A.1

Supply, install, connect and operate SUNTECH or equivalent monocrystalline solar module with all mounting structure, necessary electrical cables to connect solar cells together and to the DB's as well as inverters to have a complete operational circuit, Conduits, cable trays,earthing system and complete Main Junction Box( Fuses switch disconnectors, Diodes and others ) according to the engineer's instruction and approval. Price will include all materials needed to connect from modules to inverter and have complete job ready for installing high quality PV modules connected , to achieve minimum 7 KWp.The price includes supply and install hot galvanised steel for vertical supports, plates & screws, profiles for steel skeleton including bracing and double hot galvanizedangles for dividers. All will be as per drawings, according to the engineer's instruction and approval and price shall include costs of repairing any damaged works. The contractor should provide manufacturer's warrantee for each solar panel for a period not less than 25 years.

Module 28

A.2

Supply, install, connect and operate DC/Ac inverter/charger STECA or equivalent. The inverter depending on the system design and installation proposed .The inverter AC nominal power output rating must be equal or greater than the 7 kWp of the PV modules at standard test condition (STC). The inverter unit shall be suitable for indoor and outdoor installations. Cable terminations to inverter shall be of type DC plug and socket connectors. Technical literature has to be provided as generated by the inverters manufacturer software. Inverter shall allow an adjustable power factorOutdoor, minimum AC output power 7 kw, compatible with item (1.1), with all necessary electrical cables, Conduits and trays and all other materials and workmanship needed to connect with the main distribution panel according to the engineer's instruction and approval and have a complete job ready.

Pcs. 1

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Contractor's Signature and  Seal

Page 13: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

A.3

Supply, install, connect and operate deep cycle Batteries (12 V,150AH).GEL cell batteries provided that, deep cycle lead acid batteries (FLA), valve regulated lead acid batteries (VRLA) and Absorbed Glass Mat (AGM). The battery terminal voltage and the AH selected shall be compatible with the charge controller and the inverter selected by the designer of the P V. system. The battery efficiency shall be not less than 85% with lifetime not less than 10 years. The price include the all necessary DC electrical cables, Conduits between batteries and backup system. Also supply and install hot galvanized steel stand with shelves and dividers for hosting the batteries and all other material needed to have a complete job ready according to the engineer's instruction and approval.

unit 28

A.4

supply, install, connect and operate SMA or equivalent charger controller 7 kW at least 97% efficiency and fast sweep MMPPT Algorithm, high PV input , DC voltage with adjustable current limit. All with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others) as well as all needed protections. The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready.

No. 1

Contractor's Signature and  Seal

Page 14: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

A.5

supply, install, connect and operate SMA or equivalent Backup power 7 kW with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others). The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready (optional item).

No 1

A.6

Supply & fix galvanized steel protection for a new wall opening size 150x120cm ( the prices shall include the opening in the block, galvanized steel bars, plates and angles, the fixation accessories, painting the steel with one primer coat & two coats of oil paint, all according to the drawings, specification and engineer’s instructions (see dwg) and removal of the unwanted relevant materials to dump site approved by the engineer). The work include making good internal plastering 13 mm thick and external plastering 20mm thick to walls as well as repairing of any damages.

No 1

A.7

Supply, install,connect, test and commission wall mounted exhaust fan of 8" diameter Capacity (250 cfm) At static pressure 60 pascal for the battery room , to be tightly installed complete with all necessary supports, and all required electrical cables and ducts all according engineer’s approval.The price shall include opening duct in the block for the fan,plastering, painting , repair all damages and all other materials needed to have a completejob ready according to the engineer's instruction and approval.

No 1

Total

Contractor's Signature and  Seal

Page 15: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

B

Electrical Works:The items in general shall also include conduits, connection boxes, controls, wires, connectors, clamps, bolts, and connecting the cables to switchboards and common electric network are included in the unit price. the main aim of this item is to reconfigure the main distribution board to provide power from the PV system to the lighting system of the school and harmonize the converter with the main distribution board.• Contractor shall submit shop drawings for all electrical works to be approved by the Engineer before executing the work.• As-built drawings shall be submitted after handing over the work.• All the electrical works shall be executed according to Standards, drawings, specifications and supervisor engineer instructions.

B.1

Supply, install and commission main distribution panel board (MDB) size (80x60x30 cm) , one door,as specified and as shown on drawings, factory assembled wired and tested in accordance with international standards, including 2mm galvanized steel frame with antistatic paint, including busbars (160 A) ,neutral bus bar and earthing terminal ,and all necessary civil works for foundations,cable trenches and handing over clean, tested and in operating conditions as GEDCO specifications. (Type is MOELLER or equivalent)

NO 1

B.2

Supply and installation of a manual changeover switch (MTS) 4X40 AMB for plug-and-play between the inverter and the main AC source as drawings and instructions of the supervising engineer ,(Type is Hager, Moller or equivalent).

NO 1

B.3Miniature Circuit Breaker MCB 3X40A. (Type is Moller or equivalent).

NO 2

B.4Miniature Circuit Breaker MCB 3X25A. (Type is Moller or equivalent).

NO 2

B.5Ditto but residual current circuit breaker RCB 4X40/0.3A. (Type is Moller or equivalent).

NO 1

B.6Miniature Circuit Breaker MCB 3X32A. (Type is Moller or equivalent).

NO 2

B.7AC switch disconnector 3X32A. (Type is Moller or equivalent).

NO 3

B.8

Digital KWH meter, 3*32 A (ISKRA or equivalent) with all other material needed to have a complete job ready for installing net metering .

NO 3

B.9

B.10Ditto but PVC sub distribution-board 24 CB capacity, type is GEWISS or equivalent

NO 2

B.11 Ditto but MCB 3X16A. (Type is Moller or equivalent). NO 2B.12 Ditto but MCB 2X10A. (Type is Moller or equivalent). NO 8

B.13Ditto but residual current circuit breaker RCB 4X40/0.03A. (Type is Moller or equivalent).

NO 2

MAIN DISTRIBUTION BORD (MDB)

Sub-Distribution Boards (SDB) (B1,B2,B3)

Contractor's Signature and  Seal

Page 16: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)B.14

B.15

supplying, connecting, and termination of the following XLPE CU cables with all required electrical and civil works, the item includes dismantling and re install the existing cables and laying under ground PVC piping system, manhols, excavation, warning tapes, backfilling and all required civil works to finish the work according specifications and demands of the supervising engineer, to connect cables terminals from source to destination.The work will include re distribution of all existing loads of the main panel to achive the balance of each phase. According to drawings, specifications, instructions, and demands of the supervising engineer. as follow:

B.16 N2XY-XLPE cable 5*10 mm2 L.S 10

B.17 Flexible Single core copper wire isolated with pvc size 4mm2

L.S 50

B.18 N2XY-XLPE cable 5*6 mm2 L.S 20

Total of WORKS

Cables and conduits

Total of ELECTRICAL WORKS

Contractor's Signature and  Seal

Page 17: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Bill No (4) PV Solar Cells Project Of Rabah Adwiah School

A

PV Cells Works:The contractor must submit shopdrawings including any changes and method statement for different construction activities inclusive of all what is needed to complete the job and hand over fully operational PV powered electricity network. The electrical shopdrawings have to be accompanied with final design calculations, symbols list, site plan, and single line diagrams for distribution boards, solar switchboards, and control systems. All junction boxes and DBs will be lockable type.The price includes all builders works, making good and reinstatment including necessary materials and workmanship as well as removal of unwanted materials to dump sites approved by the engineer. In addition, it includes Supplying , installation, commissioning and operation of the PV system as well as maintenance complete with the following requirements:

A.1

Supply, install, connect and operate SUNTECH or equivalent monocrystalline solar module with all mounting structure, necessary electrical cables to connect solar cells together and to the DB's as well as inverters to have a complete operational circuit, Conduits, cable trays,earthing system and complete Main Junction Box( Fuses switch disconnectors, Diodes and others ) according to the engineer's instruction and approval. Price will include all materials needed to connect from modules to inverter and have complete job ready for installing high quality PV modules connected , to achieve minimum 15.6 KWp.The price includes supply and install hot galvanised steel for vertical supports, plates & screws, profiles for steel skeleton including bracing and double hot galvanized angles for dividers. All will be as per drawings, according to the engineer's instruction and approval and price shall include costs of repairing any damaged works. The contractor should provide manufacturer's warrantee for each solar panel for a period not less than 25 years.

Module 60

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Total Amount

US $

Contractor's Signature and  Seal

Page 18: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Total Amount

US $

A.2

Supply, install, connect and operate DC/Ac Inverter SMA or equivalent. The inverter depending on the system design and installation proposed .The inverter AC nominal power output rating must be equal or greater than the 15 kWp of the PV modules at standard test condition (STC). The inverter unit shall be suitable for indoor and outdoor installations. Cable terminations to inverter shall be of type DC plug and socket connectors. Technical literature has to be provided as generated by the inverters manufacturer software. Inverter shall allow an adjustable power factorOutdoor, minimum AC output power 15 kw, compatible with item (1.1), with all necessary electrical cables, Conduits and trays and all other materials and workmanship needed to connect with the main distribution panel according to the engineer's instruction and approval and have a complete job ready.

Pcs. 1

A.3

Supply, install, connect and operate deep cycle Batteries (12 V,150AH).GEL cell batteries provided that, deep cycle lead acid batteries (FLA), valve regulated lead acid batteries (VRLA) and Absorbed Glass Mat (AGM). The battery terminal voltage and the AH selected shall be compatible with the charge controller and the inverter selected by the designer of the P V. system. The battery efficiency shall be not less than 85% with lifetime not less than 10 years. The price include the all necessary DC electrical cables, Conduits between batteries and backup system. Also supply and install hot galvanized steel stand with shelves and dividers for hosting the batteries and all other material needed to have a complete job ready according to the engineer's instruction and approval.

unit 35

A4

supply, install, connect and operate SMA or equivalent charger controller 15 kW at least 97% efficiency and fast sweep MMPPT Algorithm, high PV input , DC voltage with adjustable current limit. All with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others) as well as all needed protections. The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready.

No. 1

Contractor's Signature and  Seal

Page 19: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Total Amount

US $

A5

supply, install, connect and operate SMA or equivalent Backup power 15 kW with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others). The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready (optional item).

No. 1

A6

Supply & fix galvanized steel protection for a new wall opening size 150x120cm ( the prices shall include the opening in the block, galvanized steel bars, plates and angles, the fixation accessories, painting the steel with one primer coat & two coats of oil paint, all according to the drawings, specification and engineer’s instructions (see dwg) and removal of the unwanted relevant materials to dump site approved by the engineer). The work include making good internal plastering 13 mm thick and external plastering 20mm thick to walls as well as repairing of any damages.

No 1

A7

Supply, install,connect, test and commission wall mounted exhaust fan of 8" diameter Capacity (250 cfm) At static pressure 60 pascal for the battery room , to be tightly installed complete with all necessary supports, and all required electrical cables and ducts all according engineer’s approval.The price shall include opening duct in the block for the fan,plastering, painting , repair all damages and all other materials needed to have a complete job ready according to the engineer's instruction and approval.

No 1

Total PV CELL

Contractor's Signature and  Seal

Page 20: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Total Amount

US $

B

Electrical Works:The items in general shall also include conduits, connection boxes, controls, wires, connectors, clamps, bolts, and connecting the cables to switchboards and common electric network are included in the unit price. the main aim of this item is to reconfigure the main distribution board to provide power from the PV system to the lighting system of the school and harmonize the converter with the main distribution board.• Contractor shall submit shop drawings for all electrical works to be approved by the Engineer before executing the work.• As-built drawings shall be submitted after handing over the work.• All the electrical works shall be executed according to Standards, drawings, specifications and supervisor engineer instructions.

B.1

Supply, install and commission main distribution panel board (MDB) size (100x60x30 cm) , one door,as specified and as shown on drawings, factory assembled wired and tested in accordance with international standards, including 2mm galvanized steel frame with antistatic paint, including busbars (160 A) ,neutral bus bar and earthing terminal ,and all necessary civil works for foundations,cable trenches and handing over clean, tested and in operating conditions as GEDCO specifications. (Type is MOELLER or equivalent)

NO 1

B.2

Supply and installation of a manual changeover switch (MTS) 4X40 AMB for plug-and-play between the inverter and the main AC source as drawings and instructions of the supervising engineer ,(Type is Hager, Moller or equivalent).

NO 1

B.3Miniature Circuit Breaker MCB 3X40A. (Type is Moller or equivalent).

NO 2

B.4Miniature Circuit Breaker MCB 3X32A. (Type is Moller or equivalent).

NO 2

B.5AC switch disconnector 3X32A. (Type is Moller or equivalent).

NO 3

B.6Miniature Circuit Breaker MCB 3X25A. (Type is Moller or equivalent).

NO 4

B.7Ditto but residual current circuit breaker RCB 4X40/0.3A. (Type is Moller or equivalent).

NO 1

B.8Digital KWH meter, 3*32 A (ISKRA or equivalent) with all other material needed to have a complete job ready for installing net metering .

NO 3

B.9

B.10Ditto but PVC distribution-board 24 CB capacity, type is GEWISS or equivalent NO

3

B.11Ditto but PVC distribution-board 12 CB capacity, type is GEWISS or equivalent NO

4

B.12Miniature Circuit Breaker MCB 3X25A. (Type is Moller or NO

5

B.13 Ditto but MCB 3X16A. (Type is Moller or equivalent). NO 7

MAIN DISTRIBUTION BORD (MDB)

Sub-Distribution Boards (SDB) (B1,…..,B7)

Contractor's Signature and  Seal

Page 21: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Total Amount

US $B.14 Ditto but MCB 2X10A. (Type is Moller or equivalent). NO 22

B.15Ditto but residual current circuit breaker RCB 4X40/0.03A. (Type is Moller or equivalent). NO

7

B.16

B.17

supplying, connecting, and termination of the following XLPE CU cables with all required electrical and civil works, the item includes dismantling and re install the existing cables and laying under ground PVC piping system, manhols, excavation, warning tapes, backfilling and all required civil works to finish the work according specifications and demands of the supervising engineer, to connect cables terminals from source to destination.The work will include re distribution of all existing loads of the main panel to achive the balance of each phase. According to drawings, specifications, instructions, and demands of the supervising engineer. as follow:

B.18 N2XY-XLPE cable 5*10 mm2 L.S 10

B.19 Flexible Single core copper wire isolated with pvc size 4mm2

L.S 400

B.20 N2XY-XLPE cable 5*6 mm2 L.S 30

Total of WORKS

Cables and conduits

Total of ELECTRICAL WORKS

Contractor's Signature and  Seal

Page 22: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Bill No (5) PV Solar Cells Project Of Harazeen Clinic

A

PV Cells WorksThe contractor must submit shopdrawings including any changes and method statement for different construction activities inclusive of all what is needed to complete the job and hand over fully operational PV powered electricity network. The electrical shopdrawings have to be accompanied with final design calculations, symbols list, site plan, and single line diagrams for distribution boards, solar switchboards, and control systems. All junction boxes and DBs will be lockable type.The price includes all builders works, making good and reinstatment including necessary materials and workmanship as well as removal of unwanted materials to dump sites approved by the engineer. In addition, it includes Supplying , installation, commissioning and operation of the PV system as well as maintenance complete with the following requirements:

A.1

Supply, install, connect and operate SUNTECH or equivalent monocrystalline solar module with all mounting structure, necessary electrical cables to connect solar cells together and to the DB's as well as inverters to have a complete operational circuit, Conduits, cable trays,earthing system and complete Main Junction Box( Fuses switch disconnectors, Diodes and others ) according to the engineer's instruction and approval. Price will include all materials needed to connect from modules to inverter and have complete job ready for installing high quality PV modules connected , to achieve minimum 12 KWp.The price includes supply and install hot galvanised steel for vertical supports, plates & screws, profiles for steel skeleton including bracing and double hot galvanized angles for dividers. All will be as per drawings, according to the engineer's instruction and approval and price shall include costs of repairing any damaged works. The contractor should provide manufacturer's warrantee for each solar panel for a period not less than 25 years.

Module 48

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Contractor's Signature and  Seal

Page 23: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

A.2

Supply, install, connect and operate DC/Ac Inverter SMA or equivalent. The inverter depending on the system design and installation proposed .The inverter AC nominal power output rating must be equal or greater than the 12 kWp of the PV modules at standard test condition (STC). The inverter unit shall be suitable for indoor and outdoor installations. Cable terminations to inverter shall be of type DC plug and socket connectors. Technical literature has to be provided as generated by the inverters manufacturer software. Inverter shall allow an adjustable power factorOutdoor, minimum AC output power 12 kw, compatible with item (1.1), with all necessary electrical cables, Conduits and trays and all other materials and workmanship needed to connect with the main distribution panel according to the engineer's instruction and approval and have a complete job ready.

Pcs. 1

A.3

Supply, install, connect and operate deep cycle Batteries (12 V,150AH).GEL cell batteries provided that, deep cycle lead acid batteries (FLA), valve regulated lead acid batteries (VRLA) and Absorbed Glass Mat (AGM). The battery terminal voltage and the AH selected shall be compatible with the charge controller and the inverter selected by the designer of the P V. system. The battery efficiency shall be not less than 85% with lifetime not less than 10 years. The price include the all necessary DC electrical cables, Conduits between batteries and backup system. Also supply and install hot galvanized steel stand with shelves and dividers for hosting the batteries and all other material needed to have a complete job ready according to the engineer's instruction and approval.

unit 48

A.4

supply, install, connect and operate SMA or equivalent charger controller 12 kW at least 97% efficiency and fast sweep MMPPT Algorithm, high PV input , DC voltage with adjustable current limit. All with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others) as well as all needed protections. The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready.

No. 1

Contractor's Signature and  Seal

Page 24: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

A.5

supply, install, connect and operate SMA or equivalent Backup power 12 kW with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others). The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready

No 1

A.6

Supply, install,connect, test and commission wall mounted exhaust fan of 8" diameter Capacity (250 cfm) At static pressure 60 pascal for the battery room , to be tightly installed complete with all necessary supports, and all required electrical cables and ducts all according engineer’s approval.The price shall include opening duct in the block for the fan,plastering, painting , repair all damages and all other materials needed to have a complete job ready according to the engineer's instruction and approval.

No 1

Total Of PV Cells

Contractor's Signature and  Seal

Page 25: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

B

Electrical Works:The items in general shall also include conduits, connection boxes, controls, wires, connectors, clamps, bolts, and connecting the cables to switchboards and common electric network are included in the unit price. the main aim of this item is to reconfigure the main distribution board to provide power from the PV system to the lighting system of the school and harmonize the converter with the main distribution board.• Contractor shall submit shop drawings for all electrical works to be approved by the Engineer before executing the work.• As-built drawings shall be submitted after handing over the work.• All the electrical works shall be executed according to Standards, drawings, specifications and supervisor engineer instructions.

B.1

Supply, install and commission main distribution panel board (MDB) size (1000x60x30 cm) , one door,as specified and as shown on drawings, factory assembled wired and tested in accordance with international standards, including 2mm galvanized steel frame with antistatic paint, including busbars (160 A) ,neutral bus bar and earthing terminal ,and all necessary civil works for foundations,cable trenches and handing over clean, tested and in operating conditions as GEDCO specifications. (Type is MOELLER or equivalent)

NO 1

B.2

Supply and installation of a manual changeover switch (MTS) 4X40 AMB for plug-and-play between the inverter and the main AC source as drawings and instructions of the supervising engineer ,(Type is Hager, Moller or equivalent).

NO 1

B.3Miniature Circuit Breaker MCB 3X40A. (Type is Moller or equivalent).

NO 2

B.4Miniature Circuit Breaker MCB 3X32A. (Type is Moller or equivalent).

NO 4

B.5AC switch disconnector 3X32A. (Type is Moller or equivalent). NO 3

B.6 Ditto but MCB 2X10A. (Type is Moller or equivalent). NO 8

B.7Ditto but residual current circuit breaker RCB 4X40/0.3A. (Type is Moller or equivalent).

NO 1

B.8Ditto but residual current circuit breaker RCB 4X40/0.03A. (Type is Moller or equivalent).

NO 1

B.9 Digital KWH meter, 3*32 A (ISKRA or equivalent) NO 3

B.10

B.11Ditto but PVC distribution-board 24 CB capacity, type is GEWISS or equivalent NO

1

B.12Miniature Circuit Breaker MCB 3X25A. (Type is Moller or equivalent). NO

1

B.13Ditto but MCB 2X10A. (Type is Moller or equivalent).

NO8

MAIN DISTRIBUTION BORD (MDB)

Sub-Distribution Boards (SDB) (B1)

Contractor's Signature and  Seal

Page 26: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

B.14Ditto but residual current circuit breaker RCB 4X40/0.03A. (Type is Moller or equivalent). NO

1

B.15

B.16

supplying, connecting, and termination of the following XLPE CU cables with all required electrical and civil works(duct , trays ,...), the item includes dismantling and re install the existing cables and laying under ground PVC piping system, manhols, excavation, warning tapes, backfilling and all required civil works to finish the work according specifications and demands of the supervising engineer, to connect cables terminals from source to destination.The work will include re distribution of all existing loads of the main panel to achive the balance of each phase. According to drawings, specifications, instructions, and demands of the supervising engineer. as follow:

B.17 N2XY-XLPE cable 5*10 mm2 L.S 10

B.18 Flexible Single core copper wire isolated with pvc size 4mm2

L.S 50

B.19 N2XY-XLPE cable 5*6 mm2 L.S 25

Total of WORKS

Cables and conduits

Total of ELECTRICAL WORKS

Contractor's Signature and  Seal

Page 27: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Bill No (6) PV Solar Cells Project Of Beit El Maqdes Clinic

PV Cells Works:The contractor must submit shopdrawings including any changes and method statement for different construction activities inclusive of all what is needed to complete the job and hand over fully operational PV powered electricity network. The electrical shopdrawings have to be accompanied with final design calculations, symbols list, site plan, and single line diagrams for distribution boards, solar switchboards, and control systems. All junction boxes and DBs will be lockable type.The price includes all builders works, making good and reinstatment including necessary materials and workmanship as well as removal of unwanted materials to dump sites approved by the engineer. In addition, it includes Supplying , installation, commissioning and operation of the PV system as well as maintenance complete with the following requirements:

A.1

Supply, install, connect and operate SUNTECH or equivalent monocrystalline solar module with all mounting structure, necessary electrical cables to connect solar cells together and to the DB's as well as inverters to have a complete operational circuit, Conduits, cable trays,earthing system and complete Main Junction Box( Fuses switch disconnectors, Diodes and others ) according to the engineer's instruction and approval. Price will include all materials needed to connect from modules to inverter and have complete job ready for installing high quality PV modules connected , to achieve minimum 10 KWp.The price includes supply and install hot galvanised steel for vertical supports, plates & screws, profiles for steel skeleton including bracing and double hot galvanized angles for dividers. All will be as per drawings, according to the engineer's instruction and approval and price shall include costs of repairing any damaged works. The contractor should provide manufacturer's warrantee for each solar panel for a period not less than 25 years.

Module 48

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Contractor's Signature and  Seal

Page 28: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

A.2

Supply, install, connect and operate DC/Ac inverter/charger STECA or equivalent. The inverter depending on the system design and installation proposed .The inverter AC nominal power output rating must be equal or greater than the 10kWp of the PV modules at standard test condition (STC). The inverter unit shall be suitable for indoor and outdoor installations. Cable terminations to inverter shall be of type DC plug and socket connectors. Technical literature has to be provided as generated by the inverters manufacturer software. Inverter shall allow an adjustable power factorOutdoor, minimum AC output power 10 kw, compatible with item (1.1), with all necessary electrical cables, Conduits and trays and all other materials and workmanship needed to connect with the main distribution panel according to the engineer's instruction and approval and have a complete job ready.

Pcs. 1

A.3

Supply, install, connect and operate deep cycle Batteries (12 V,150AH).GEL cell batteries provided that, deep cycle lead acid batteries (FLA), valve regulated lead acid batteries (VRLA) and Absorbed Glass Mat (AGM). The battery terminal voltage and the AH selected shall be compatible with the charge controller and the inverter selected by the designer of the P V. system. The battery efficiency shall be not less than 85% with lifetime not less than 10 years. The price include the all necessary DC electrical cables, Conduits between batteries and backup system. Also supply and install hot galvanized steel stand with shelves and dividers for hosting the batteries and all other material needed to have a complete job ready according to the engineer's instruction and approval.

unit 40

A.4

supply, install, connect and operate SMA or equivalent charger controller 10 kW at least 97% efficiency and fast sweep MMPPT Algorithm, high PV input , DC voltage with adjustable current limit. All with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others) as well as all needed protections. The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready.

No. 1

Contractor's Signature and  Seal

Page 29: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

A.5

supply, install, connect and operate SMA or equivalent Backup power 10 kW with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others). The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready (optional item).

No 1

A.6

Supply & fix galvanized steel protection for a new wall opening size 150x120cm ( the prices shall include the opening in the block, galvanized steel bars, plates and angles, the fixation accessories, painting the steel with one primer coat & two coats of oil paint, all according to the drawings, specification and engineer’s instructions (see dwg) and removal of the unwanted relevant materials to dump site approved by the engineer). The work include making good internal plastering 13 mm thick and external plastering 20mm thick to walls as well as repairing of any damages.

No 1

A.7

Supply, install,connect, test and commission wall mounted exhaust fan of 8" diameter Capacity (250 cfm) At static pressure 60 pascal for the battery room , to be tightly installed complete with all necessary supports, and all required electrical cables and ducts all according engineer’s approval.The price shall include opening duct in the block for the fan,plastering, painting , repair all damages and all other materials needed to have a complete job ready according to the engineer's instruction and approval.

No 1

Total of PV Cell

Contractor's Signature and  Seal

Page 30: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

B

Electrical Works:The items in general shall also include conduits, connection boxes, controls, wires, connectors, clamps, bolts, and connecting the cables to switchboards and common electric network are included in the unit price. the main aim of this item is to reconfigure the main distribution board to provide power from the PV system to the lighting system of the school and harmonize the converter with the main distribution board.• Contractor shall submit shop drawings for all electrical works to be approved by the Engineer before executing the work.• As-built drawings shall be submitted after handing over the work.• All the electrical works shall be executed according to Standards, drawings, specifications and supervisor engineer instructions.

B.1

Supply and installation of a manual changeover switch (MTS) 4X40 AMB for plug-and-play between the inverter and the main AC source as drawings and instructions of the supervising engineer ,(Type is Hager, Moller or equivalent).

NO 1

B.2Miniature Circuit Breaker MCB 3X40A. (Type is Moller or equivalent).

NO 2

B.3Miniature Circuit Breaker MCB 3X32A. (Type is Moller or equivalent).

NO 2

B.4AC switch disconnector 3X32A. (Type is Moller or equivalent).

NO 3

B.5Miniature Circuit Breaker MCB 3X25A. (Type is Moller or equivalent).

NO 2

B.6Ditto but residual current circuit breaker RCB 4X40/0.3A. (Type is Moller or equivalent).

NO 1

B.7Digital KWH meter, 3*32 A (ISKRA or equivalent) with all other material needed to have a complete job ready for installing net metering .

NO 3

B.8

B.9Ditto but PVC distribution-board 24 CB capacity, type is GEWISS or equivalent NO

2

B.10Miniature Circuit Breaker MCB 3X25A. (Type is Moller or equivalent). NO

1

B.11 Ditto but MCB 3X16A. (Type is Moller or equivalent). NO 2B.12 Ditto but MCB 2X10A. (Type is Moller or equivalent). NO 13

B.13Ditto but residual current circuit breaker RCB 4X40/0.03A. (Type is Moller or equivalent). NO 2

MAIN DISTRIBUTION BORD (MDB)

Sub-Distribution Boards (SDB) (B1,B2)

Contractor's Signature and  Seal

Page 31: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)B.14

B.15

supplying, connecting, and termination of the following XLPE CU cables with all required electrical and civil works(duct , trays ,...), the item includes dismantling and re install the existing cables and laying under ground PVC piping system, manhols, excavation, warning tapes, backfilling and all required civil works to finish the work according specifications and demands of the supervising engineer, to connect cables terminals from source to destination.The work will include re distribution of all existing loads of the main panel to achive the balance of each phase. According to drawings, specifications, instructions, and demands of the supervising engineer. as follow:

B.16 Flexible Single core copper wire isolated with pvc size 4mm2

L.S 30

B.17 N2XY-XLPE cable 5*6 mm2 L.S 30

Total of WORKS

Cables and conduits

Total of ELECTRICAL WORKS

Contractor's Signature and  Seal

Page 32: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Bill No (7) PV Solar Cells Project Of Right to live society

A

PV Cells Works:The contractor must submit shopdrawings including any changes and method statement for different construction activities inclusive of all what is needed to complete the job and hand over fully operational PV powered electricity network. The electrical shopdrawings have to be accompanied with final design calculations, symbols list, site plan, and single line diagrams for distribution boards, solar switchboards, and control systems. All junction boxes and DBs will be lockable type.The price includes all builders works, making good and reinstatment including necessary materials and workmanship as well as removal of unwanted materials to dump sites approved by the engineer. In addition, it includes Supplying , installation, commissioning and operation of the PV system as well as maintenance complete with the following requirements:

A.1

Supply, install, connect and operate SUNTECH or equivalent monocrystalline solar module with all mounting structure, necessary electrical cables to connect solar cells together and to the DB's as well as inverters to have a complete operational circuit, Conduits, cable trays,earthing system and complete Main Junction Box( Fuses switch disconnectors, Diodes and others ) according to the engineer's instruction and approval. Price will include all materials needed to connect from modules to inverter and have complete job ready for installing high quality PV modules connected , to achieve minimum 12 KWp.The price includes supply and install hot galvanised steel for vertical supports, plates & screws, profiles for steel skeleton including bracing and double hot galvanized angles for dividers. All will be as per drawings, according to the engineer's instruction and approval and price shall include costs of repairing any damaged works. The contractor should provide manufacturer's warrantee for each solar panel for a period not less than 25 years.

Module 48

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Contractor's Signature and  Seal

Page 33: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

A.2

Supply, install, connect and operate DC/Ac Inverter SMA or equivalent. The inverter depending on the system design and installation proposed .The inverter AC nominal power output rating must be equal or greater than the 12kWp of the PV modules at standard test condition (STC). The inverter unit shall be suitable for indoor and outdoor installations. Cable terminations to inverter shall be of type DC plug and socket connectors. Technical literature has to be provided as generated by the inverters manufacturer software. Inverter shall allow an adjustable power factorOutdoor, minimum AC output power 12 kw, compatible with item (1.1), with all necessary electrical cables, Conduits and trays and all other materials and workmanship needed to connect with the main distribution panel according to the engineer's instruction and approval and have a complete job ready.

Pcs. 1

A.3

Supply, install, connect and operate deep cycle Batteries (12 V,150AH).GEL cell batteries provided that, deep cycle lead acid batteries (FLA), valve regulated lead acid batteries (VRLA) and Absorbed Glass Mat (AGM). The battery terminal voltage and the AH selected shall be compatible with the charge controller and the inverter selected by the designer of the P V. system. The battery efficiency shall be not less than 85% with lifetime not less than 10 years. The price include the all necessary DC electrical cables, Conduits between batteries and backup system. Also supply and install hot galvanized steel stand with shelves and dividers for hosting the batteries and all other material needed to have a complete job ready according to the engineer's instruction and approval.

unit 12

A.4

supply, install, connect and operate SMA or equivalent charger controller 12 kW at least 97% efficiency and fast sweep MMPPT Algorithm, high PV input , DC voltage with adjustable current limit. All with all necessary electrical cables including conduits , trays and complete Main Junction Box( Fuse switch disconnectors and others) as well as all needed protections. The work includes connecting to the main distribution panel according to the engineer's instruction and approval.and all other material needed to have a complete job ready.

No. 1

Total

Contractor's Signature and  Seal

Page 34: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

B

Electrical Works:The items in general shall also include conduits, connection boxes, controls, wires, connectors, clamps, bolts, and connecting the cables to switchboards and common electric network are included in the unit price. the main aim of this item is to reconfigure the main distribution board to provide power from the PV system to the lighting system of the school and harmonize the converter with the main distribution board.• Contractor shall submit shop drawings for all electrical works to be approved by the Engineer before executing the work.• As-built drawings shall be submitted after handing over the work.• All the electrical works shall be executed according to Standards, drawings, specifications and supervisor engineer instructions.

B.1

Supply, install and commission main distribution panel board (MDB) size (100x80x30 cm) , one door,as specified and as shown on drawings, factory assembled wired and tested in accordance with international standards, including 2mm galvanized steel frame with antistatic paint, including busbars (160 A) ,neutral bus bar and earthing terminal ,and all necessary civil works for foundations,cable trenches and handing over clean, tested and in operating conditions as GEDCO specifications. (Type is MOELLER or equivalent) NO 1

B.2

Supply and installation of a manual changeover switch (MTS) 4X40 AMB for plug-and-play between the inverter and the main AC source as drawings and instructions of the supervising engineer ,(Type is Hager, Moller or equivalent). NO 2

B.3Miniature Circuit Breaker MCB 3X40A. (Type is Moller or equivalent). NO 2

B.4 Miniature Circuit Breaker MCB 3X32A. (Type is Moller NO 2

B.5AC switch disconnector 3X32A. (Type is Moller or equivalent). NO 3

B.6Miniature Circuit Breaker MCB 3X25A. (Type is Moller or equivalent). NO 4

B.7Ditto but residual current circuit breaker RCB 4X40/0.3A. (Type is Moller or equivalent). NO 1

B.8Ditto but residual current circuit breaker RCB 4X40/0.03A. (Type is Moller or equivalent). NO 1

B.9 Ditto but MCB 2X10A. (Type is Moller or equivalent). NO 8

B.10

Digital KWH meter, 3*32 A (ISKRA or equivalent) with all other material needed to have a complete job ready for installing net metering .

NO 3

MAIN DISTRIBUTION BORD (MDB)

Contractor's Signature and  Seal

Page 35: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

B.11

Supply, installation & commissioning of AC Variable Frequency Drive (V.F.D.) suitable for 10 HP VT, at full load 7.5 Kw,380-480V, 50Hz, 3phase, 16 Amp, IP54,VFD having efficiency 95% also offered power factor 0.95 or better. Type Delta (VFD075C43A) , Danfoss OR equivelent ,with all other material needed to have a complete job ready for operation NO 1

B.12

B.13Ditto but PVC distribution-board 24 CB capacity, type is GEWISS or equivalent NO

2

B.14 Ditto but MCB 3X16A. (Type is Moller or equivalent). NO 2B.15 Ditto but MCB 2X10A. (Type is Moller or equivalent). NO 10

B.16Ditto but residual current circuit breaker RCB 4X40/0.03A. (Type is Moller or equivalent). NO

2

B.17

B.18

supplying, connecting, and termination of the following XLPE CU cables with all required electrical and civil works, the item includes dismantling and re install the existing cables and laying existing conduties, PVC piping system, manhols, excavation, warning tapes, backfilling and all required civil works to finish the work according specifications and demands of the supervising engineer, to connect cables terminals from source to destination.The work will include re distribution of all existing loads of the main panel to achive the balance of each phase. According to drawings, specifications, instructions, and demands of the supervising engineer. as follow:

B.19 N2XY-XLPE cable 5*16 mm2 L.S 40B.20 N2XY-XLPE cable 5*6 mm2 L.S 10B.21 N2XY-XLPE cable 5*4 mm2 L.S 40

Total of WORKS

Sub-Distribution Boards (SDB) (B1,B2,B3)

Cables and conduits

Total of ELECTRICAL WORKS

Contractor's Signature and  Seal

Page 36: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Bill No (8) Civil Works for 7 rooms in 7 sites

8.1

Supply and cast ready mix reinforced concrete B250 kg/ cm2 for suspended hollow block slab 20 cm thick , including the reinforced steel, drop and inverted beams, hollow cement block 40*25*14, and all other materials needed to finish the work as per specifications and drawings.

m2 140

Total Amount

US $CONCRETE works: Rates of Concrete Works shall include:-1. All form works and shuttering (new number for shuttering painted by special oil ) in any form, shape and size . Making chamfered and curved edges, allowing for and making grooves and sleeves and using Tie Rods (Batant) for concrete walls ; removal of forms and cleaning of all exposed tie wires and rods. Steel forms must be used in shuttering the external decorations.2. Fuel or burned oil is not accepted to be used for painting the lumber before use the form.3. Supplying, Casting, vibrating and curing as per specifications.4. Approved additives and admixtures.5. Incurred costs on New Concrete Job Mix Designs, Sampling , testing and providing test results certificates, storing and saving of samples.6. Painting of exposed surfaces of underground reinforced concrete elements with two coats of hot bituminous paint (75/25) after primer layer , the strokes of each layer to be opposite to each other.7. Preliminary installations for Electrical, plumbing and floor drainage in floor slabs including final floor slab.8. Compaction and testing under the foundation, ground beams, and ground slabs, the compaction should not be less than 98% of MDD.9. All works according to specifications , drawings and supervisor engineer instructions Note : All prices of concrete item should include the steel reinforcement works as the follwoing:10.Supply, fabricate and fix reinforcement steel (fy= 410 N/mm2) for all the structural elements according to drawings and engineer's instructions for any grade, size and length as detailed in the drawings, storing on site including cutting, bending and fixing in position and providing all tying wires, spacers, shop drawings, testing and bar bending schedules .All works according to specifications , drawings and supervisor engineer instructions

8

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

Contractor's Signature and  Seal

Page 37: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

8.2 Ditto but for lintels and sills. m3 14

8.3 Ditto but B300, for columns m3 14

8.4

BLOCK works: The price include: 1- supplying hollow cement block from good and approved factory in perfect dimension and build it in good manner with a compressive strength 35 kg/cm2 for hollow block. This item will include cement mortars, reinforced concrete infill (B250) between columns & block walls (10-20 cm wide) with 1Ø8mm/40cm horizontally and 2Ø8mm vertically according to drawings, pipes encasement, false columns 20x20 cm/4.0m among the parapet wall with 4Ø12mm and bituminous paper between block work and drop beams & all requirements needed to finish the works according to the drawings, specification and to the supervision engineer instructions.

8.5Supply and build hollow cement blocks 40x20x20cm.

m2 400

8.6 Ditto but 40x20x 15 cm thick for the parapet wall m2 70

8.7

Plastering WorksAll works must be according to drawings, specification and engineer instructions. Rates shall include :Supply of all needed materials, including galvanized angles for the corners as well as the use of galvanized wire mesh between concrete and block work. Preparation works by covering all conduits of electricity, water supplies , etc, with a galvanized wire mesh at least 20cm width coated by mortar (1:1) cement : sand and the work includes removal of wires and nails and cleaning of surfaces to be ready for plastering. Contractor shall take into consideration that all – direct and indirect works and expenses required for the completion of the coming items are included in the unit price.The work includes closing all opening in existing walls, as opening around existing (plumbing, electrical) and between existing walls and slabs by using Galvanized mesh and mortar cement.Complete and repair all defects, cracks, opening and etc. in existing plastering according to engineer's instruction.Trimming of concrete chippings, removing the wires and etc. from existing concrete, and cleaning of existing surfaces to be ready for plastering.The work shall include checking out all of the preliminary installation in ceilings and walls such as electrical, water supply and waste water pipes and repairing the damages if any.This should be done prior to commencement of plastering and after obtaining a written approval from the supervisor engineer.Curing with water for at least three days for each coat.

Contractor's Signature and  Seal

Page 38: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

8.8

Supply and make internal plastering 13 mm thick for ceiling and soffits. The work includes rough primer nail rendering to form a key with (mix 1:1) cement sand, second layer 13mm: Base-Coat "Rendering" with (1:3:0.25) cement: sand mortar: lime and third layer: Finishing Coat with (1:4:0.50) cement: sand mortar: lime . Works include all materials needed to finish the works according to specifications , drawings and supervisor engineer's instructions m2 500

8.9

Supply and make external plastering 20mm thick to walls with four faces : the first is the rough nail rendering (mix 1:1) cement sand; the second is 5mm thick mortar (mix 1: 2) cement:sand, the third is the undercoat 13mm (mix 1: 3 :0.25) cement:sand:lime, the forth is two coats of Tyrolean finish ( mix 1: 3) white cement to fine aggregate (Quartz) and all is according to specifications , drawings and supervisor engineer's instructions

m2 420

8.10

Painting Works: 1-All the painting materials used should be approved and tested by approved local laboratory and have the final approved from the supervisor engineer.2- The surface must be dry and clean before painting. 3- All painting works should provide the required coverage.4- All paint works must be according to specifications , drawings and supervisor engineer instructions.5- Contractor shall take into consideration that all – direct and indirect works and expenses required for the completion of the coming items are included in the unit price.6-Smoothen surfaces of existing plastering before the

8.11

Supply and Paint the internal walls and walls with one coat primer and at least two coats of approved supetrcrile as specifications , drawings and supervisor engineer instructions m2 500

8.12

Supply and Paint, external walls with one coat of Pendrole primer and at least two coats of External quality of white and colored emulsion (Weather Shield) or equal approved as specification and drawings including the maintinance of the existing tryolyne (Rashga) if needed. m2 420

8.13

METAL works: The item include supplying white aluminum windows section 7000 with two rails, with min. wall thick 1.25mm(be approved by representative engineer )as frame, glass 4 mm thick, fironmongery , accessories and hard ware as per specification and drawings.-Steel work should be Paint with two coats of oil paint &

8.14Supply and fix aluminum window, overall size 120x120cm. No 2

8.15

Supply fix and paint flush galvanized steel single leaf door all fittings overall size 110x220cm, double sheet (2-mm), complete with frame ,ironmongery, hardware with locked type wally switch or equivalents. .as per specification and drawings. No 1

Contractor's Signature and  Seal

Page 39: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

Total Amount

US $

Item No.

Description Unit Quantity Unit Rate

US $ (letters)

Unit Rate US $

(Numbers)

8.16

Supply and fix galvanized steel protection for windows over all size 120x110 cm .the prices including mild steel frame size 8mm thick x 40mm wide, vertical steel plate size 20mm wide x 8mm thick fixed every 12cm C.C by welding to the frame and circular steel plate size 20x2mm as stiffeners and two horizontal steel stiffeners size 20x8mm. Fixed on walls by steel angle ties, painting with oil paint, all according to drawing, specification and engineer instructions. No 2

8.17

B- Tiles works: All works must be according to drawings, specification and engineer instructions. Rates shall include : 1. Samples for approval and all the required tests.2. Cleaning, mechanical polishing and pointing using grout.3.Insulation works under ceramic floor tiles for upstairs bath rooms and kitchens using primer coat, two hot bitumen coats (75/25) 4. Plastic angle beads for ceramic wall tiles and Aluminum angle for ceramic of walls at the corners and top and sides of ceramic edges.5. Local marble must be Grade (A) free cracks and clay flaws.6. Measuring the stockpiled quantities of tiles and obtaining the engineer approval prior to shipment to the site. 7.Transporting and carefully handling the stored

8.18

Supply and install terrazzo floor tiles size 25cmx25cmx2.5cm with Basalt stone laid on 2cm mortar bed and 5 cm thick sand bed and the price including terrazzo skirting of same kind and color of the floor tiles 25cmx7cm x1cm thick laid on 1 cm mortar m2 140

8.19

Supply and install local marble (grade A) size 25 cm wide x 3cm thick for windows sills laid on 2 cm thick mortar bed as approved by the engineer. m.r 3

Total of WORKS

Contractor's Signature and  Seal

Page 40: ITB 2013-059 -BOQ.xlsx

Renewable Energy Generation through Solar Panels ITB 2013‐059

1

2

3

4

5

6

7

8

AL Faloga School

Summary

Bill No. Description Total (Us $)

Bashir Al Rayes School

VAT(0%)TOTAL

A'Aka School

Raba Adawia School

Harazeen Clinic

Beit Al Maqdes Clinic

Civil Works

Total Works

Right to live society

Telephone………………………………………………………………

Fax ………………………………………………………………………

Mobile …………………………………………………………………..

Total in numbers .........................................................................

Total in letters ..............................................................................

Name of the contractor ………….………..………………………

Authorized signature ……………...………………….……………..

Signature and Sealing………………………………………………

Title ………………………………………..……………………………

ITB 2013‐059 ‐BOQ.xlsx