iStan iStan v2 now with Müse - BAES · new iStan now comes standard with Müse, the ... for...

6
iStan ® iStan v2 now with Müse

Transcript of iStan iStan v2 now with Müse - BAES · new iStan now comes standard with Müse, the ... for...

Page 1: iStan iStan v2 now with Müse - BAES · new iStan now comes standard with Müse, the ... for instructor/learner debriefing ... COPD Exacerbation with Respiratory Failure

iStan®

iStan v2 now with Müse

Page 2: iStan iStan v2 now with Müse - BAES · new iStan now comes standard with Müse, the ... for instructor/learner debriefing ... COPD Exacerbation with Respiratory Failure

Fluid loss and administration controls support varying rates.

Multi-user, unique password system allows institutions to predefine privileges of users and operators.

The fully customizable Quick Links lists help you easily and accurately apply complex medical conditions, medications and interventions directly from the Run Screen.

Müse is a smart application that displays only the features available on the simulator you are connected to, allowing you to access the level of physiologic control available at any given time.

Patient reset button allows you to quickly save and return to the patient’s original baseline physiology without having to restart the SCE.Scenarios automatically load

as part of the SCE. Scenario states and progression can be controlled directly from the Run Screen.

Patient Status Display provides a fully custom-izable, manageable view of waveform, numeric and volumetric patient data. Colors and alarms can be modified directly from the Run Screen as well.

Parameter controls allow you to affect the physiological modeling with the click of a button.Recent Event Logs on

the Run Screen keep you updated, while complete event and physiological data is logged in the SCE history.

Simulated Clinical Experiences (SCEs) bundle ready-to-go patient, scenarios, educational content and setup preferences to automatically load together when you run a SCE.

SCE timeline provides the ability to place bookmarks throughout a SCE and to return to the patient’s book-marked physiology at any point.

Medication Monitor shows current concentration of any administered medication in the patient. Administered drugs can be “reset,” immediately removing all effects of the medication from the patient for training purposes.

Drug responses are tied to route administration options (IV, IM, PO, IO, Transdermal Patch, Nasal Spray, and Transmucosal Lozenge).

The new iStan comes standard with METI’s extraordinary, new user interface, Müse. From running your simulator to accessing and managing patients and scenarios, Müse offers drag-and-drop simplicity and touch-screen capability, making control as simple as a tap of the finger. Müse runs on web-based technology, so it connects wirelessly to your network and comes with METI’s TouchPro™ Patient Monitor software including capnography.* In addition, with Müse for iStan, all of METI’s proprietary physiology and pharmacology models have been updated and enhanced.

iStan v2 + Müse:the ultimate learning package

Page 3: iStan iStan v2 now with Müse - BAES · new iStan now comes standard with Müse, the ... for instructor/learner debriefing ... COPD Exacerbation with Respiratory Failure

Bilateral femoral pulse

Reactive eyes with automatic and manual, consensual and independent pupillary response and control

Blinking eyes

Variable pupil size

Realistic airway

Breakaway teeth

Voice

Trismus

Trachea with realistic anatomical landmarks

Bilateral carotid pulse

Bilateral chest tube Bilateral

IV port

Bowel sounds

Bilateral brachial pulse

Urinary outputBilateral radial pulse

NEW

Inspired evolutionBilateral chest movement

Flail chest

Pneumothorax decompression

Independent chest excursion

Breath sounds

Heart sounds

Intercostal palpable ribs

Chest compressions

ECG

Defibrillation

Pacing

Fully wireless and tetherless with

everything from blood, fluids and

power 100% on-board

NEW

DiaphoresisRealistic secretions: eyes, nose, mouth, ears

Simultaneous bleeding sites

Instructors Workstation

Page 4: iStan iStan v2 now with Müse - BAES · new iStan now comes standard with Müse, the ... for instructor/learner debriefing ... COPD Exacerbation with Respiratory Failure

Bilateral popliteal pulse

Intraosseous access

Bilateral dorsalis and tibialis pedis pulses

Realistic skin

Six patients and 14 Simulated Clinical Experiences™ (SCEs)

NEW

New, advanced featuresReskinned – an advanced realistic skin that is more ruggedized for use in every kind of learning environ- ment, whether it’s in the classroom or at a disaster drill in the field.

Reactive eyes – fully reactive eyes providing both consensual and independent, automatic pupillary response to light and trauma.

Improved airway – built to withstand all the rigors associated with practicing proper airway management.

Quieter operation – new, low-noise system lets you hear patient sounds – not mechanics – for added realism in your simulation environment while the patient is breathing.

High-quality patient sounds – louder and clearer audio quality for voice, lung and heart sounds.

New software: Müse – iStan now comes standard with METI’s new user interface that combines all the power of METI’s physiological models with intuitive, “on-the-fly” control.

Welcome to the new iStanWhen you need high-performance and ultra-realism in a patient simulator look no further than the all-new, next-generation iStan. The new iStan brings you every-thing you love about the ultimate wireless simulator – a 100% all-in-one system, fully articulated movement and tetherless control – with new and improved features that make it simply the most powerful and most advanced patient simulator in the world. And, the new iStan now comes standard with Müse, the new METI touch-screen-capable user interface that makes everything about running your simulator easier, faster and friendlier.

Cyanosis

Capillary refill

TouchPro Software

Page 5: iStan iStan v2 now with Müse - BAES · new iStan now comes standard with Müse, the ... for instructor/learner debriefing ... COPD Exacerbation with Respiratory Failure

TouchPro Simulated Patient Monitoring SoftwareMüse comes with the new TouchPro Patient Monitoring software that looks and acts just like a real-world patient monitor including touch-screen capability and capnography.*

• OperateswirelesslyorviawiredEthernet• Canberunonatouch-screencomputerortablet• Waveformsandnumericvitalscanbechangedwith drag and drop simplicity•Candisplayuptosixwaveformtracesandfour numeric vitals• Web-basedforPCorMac

Numeric Selection• Heart Rate• Pulse• Arterial Blood Pressure• MAP• NIBP• Pulmonary Artery Pressure• PCWP• Central Venous Pressure• ContinuousCardiacOutput• Thermodilution Cardiac Output• Respiratory Rate

• SpO2

• PAO2

• PaO2

• PACO2

• PaCO2

• EtCO2

• PvO2

• PvCO2

• ICP• Body Temperature• Blood Temperature• Axillary Temperature• Rectal Temperature

Waveform Selection• ECGLeadI• ECGLeadII• ECGLeadIII• ECGLeadV

• ArterialBloodPressure•CentralVenousPressure•Optoplethysmograph• Capnogram• PulmonaryBloodPressure

* Touch-screen hardware is available as an option.

Page 6: iStan iStan v2 now with Müse - BAES · new iStan now comes standard with Müse, the ... for instructor/learner debriefing ... COPD Exacerbation with Respiratory Failure

For more information about iStan or other METI products contact your regional sales manager, the distributor in your country or visit meti.com.

© 2011 M

ETI 177-0611

SouNdSBreath Sounds

8 anterior locations: 4 independently con-trolled breath sounds (7 options available)6 posterior locations: 4 independently con-trolled breath sounds (7 options available)

Heart Sounds 4 independently controlled heart sound locations (9 options available)

Bowel Sounds 4 independently controlled bowel sound locations (4 options available)

Phonation Sounds Throat Sounds - cough, stridor Male and Female Speech - yes, no, ouch and more Wireless Voice Capability (live speech)

Pulmonary SystemLung design allows for simulation of flail chest and variable airway resistance Independent Bilateral Trauma features (needle decompression/chest tubes) End Tidal CO2 monitoring

CaRdIovaSCulaR SySTeMJugular Vein Distention Defibrillation, Pacing and Cardioversion Chest Compressions Cyanosis Capillary Refill

PulSeSPneumatic pulses in 14 locations Bilateral Carotid Bilateral Brachial Bilateral Radial Bilateral Femoral Bilateral Popliteal Bilateral Dorsalis Pedis Bilateral Tibialis Pedis Pulses are touch activated and logged for instructor/learner debriefing

geNITouRINaRyInterchangeable male or female genitalia for urinary catheterization procedures and urinary output

TRauMaCricothyrotomy Articulated Mandible Obstructed Ear Irrigation Oral and Nasopharyngeal Suctioning Neck Articulation with cervical motion monitoring and the ability to reduce range of motion Reactive Pupils Teeth with Break Away Incisors Laryngospasm Difficult (Airway) OccluderBronchial Occlusion Tongue Edema Trismus Jaw Thrust (Sensed) Tension Pneumothorax/Hemothorax Needle Decompression (Bilateral) Flail Chest Chest Tubes (Bilateral) Convulsions Sternal and Tibial IO Access Bilateral Peripheral IV Ports Central (Femoral and Jugular) IV Lines Bilateral Thigh Auto-Injection Sites for Medication Administration

BleedINg aNd SeCReTIoNSHemorrhage System

Simulation of bleeding at Moulage Sites (2 simultaneously) Plumbed for all four limbs and abdomen Linked to physiology

Secretions Mouth, nose, ears, eyes, forehead diaphoresis Also serves the chest tubes and urinary output

PoWeR aNd eleCTRoNICSAC/DC Power (110/240 V AC, 12-24 V DC) Batteries Internal Rechargeable Batteries Battery run-time: 8 hours Fast charge: Approximately 5 hours

MoNIToRINgSpo2

Finger Probe integrated with Simulated Patient Monitor Display and METI Physiological Models

eCg 5-lead ECG monitoring available on both patient monitors and TouchPro Monitor Display

NIBP Blood pressure assessment by palpitation and auscultation (Korotkoff sounds) and is displayed on TouchPro Monitor DisplayAuto-Cycling Capable

SIMulaTed ClINICal exPeRIeNCeSAnaphylaxis Angina with Cardiac Arrest Anterior Myocardial Infarction Asthmatic with Pneumothorax COPD Exacerbation with Respiratory Failure Heart Failure with Pulmonary Edema Inferior Myocardial Infarction Organophosphate Exposure Pneumonia with Septic Shock Severe Young Asthmatic Splenic Rupture with Pneumothorax Stab Wound to the Chest Subdural Hematoma Tension Pneumothorax

STaNdaRd eQuIPMeNTiStan Mannequin Instructor’s Workstation Laptop Müse iStan Edition Software 4 SCE Development LicensesTouchPro Software 14 Preconfigured SCEsSet of 4 CO

2 Canisters

iStan Computer BagSix Patients • Healthy Adult Male • Pregnant Female • Healthy Adult Female • COPD Patient • Healthy Soldier • Hypertensive Patient

oPTIoNal eQuIPMeNTTouch-screen Capable Monitor Additional Battery Pack Mannequin Carrying Case Additional CO

2 Canisters

Mannequin Tool Kit Trauma/Disaster Casualty Kit - TDCK™ METI FXICPPharmacology Editor

6300 Edgelake Drive Sarasota,FL34240USA tel 941-377-5562 meti.com hpsn.com

iStan Clinical Features