Isolated high speed 8 channel multi function logger
midi LOGGER GL900midi LOGGER GL900
Product introduction Product introduction
The data logger that meets The data logger that meets with various equipment testswith various equipment tests NEW
GRAPHTEC CORPORATION
Out line Out line Recently, improvement of product durability becomes more important as a development theme for the electronics equipments and industrial equipments, so the drop down test, vibration test, mechanical shock test and environment test have been performed more frequently. Especially for the durability test for mechanical movement parts and driving parts, several ten thousands times or several thousands hours durability test are often performed.Based on these backgrounds, high speed sampling and long time data capturing and simultaneous measurement for several phenomena (voltage, temperature and high voltage) are strongly required for the measurement equipments. Also for the long time durability test for multiple products, it is required that the number of test equipment needs to be increased, so compact and reasonable price measurement equipments are required for capturing of these test data.
We provide the midi LOGGER GL900 that is an 8 channels isolation input for safe measurement for these various product tests. Further more, the multifunction input which corresponds to 500V DC high voltage, humidity, pulse and logic input for measurement of various phenomena.
Target of the GL900Target of the GL900
Company H
8835
1MS/s 100KS/s
Company K
NR600
Company K GR7000
Company Y
DL750P
Company N RA2300
Company H
8860-50
How many customers measure 1MS/s measurement by their measurement equipment which has the 1 MS/s sampling capability?We guess that the actual measurement 100 KS/s (10 micro second sampling) or slower, isn ’t it?Graphtec provides practical specification and price of products to meet customer’s actual frequency band.
Price(MSRP)1.1
0.3
0.6
1.0
Instantaneous phenomenon ・ Drop down test・ Mechanical shock test・ Vibration test
Long time measurement・ Durability test・ Tension/Compression test・ Environment test
Main application
GL900: Competitive price
8 channels, isolation, simultaneous sampling
Sampling Speed ( Sample / sec )
Company Y
SL1400
Company H 8841
(Million yen)
>Large size 5.7 inch color LCD for bright and easy- to- read waveform display
> Data capture for USB memory which can easily be connected to the PC
> 16 bits A/D resolution with High speed 8 channels simultaneous sampling
>8 channels isolated multi function input
Main features Main features
Isolated high speed 8 ch multi function loggerIsolated high speed 8 ch multi function logger
The midi LOGGER GL series are popular as the handy type logger, now, the GL900 is designed as vertical operation for customer’s usage.Also the size is drastically reduced as an isolated high speed measurement equipment.
232mm
150mm
80mm
4 ch for either Logic or PulseFor pulse, Revolutions, Counts, Instant are selectable for each channels
BNC terminal for easy connection of voltage input
Screw terminal for easy connection of thermo couples
Isolated input for safe connection and variety of input ranges for corresponding various test items
Voltage : 20 mV to 500 V (Between + and - terminals : Max 500 V p-p)
Temperature : Thermocouple Humidity : Humidity sensor (B-530) Logic or Pulse : (Revolution, Integration and Instant)
4ch separated from analog 8ch input
Multi-function input with isolated 8 channels Multi-function input with isolated 8 channels
Corresponding to high voltage measurementCorresponding to high voltage measurement
ACpower supply
Sequence : Logic
Current : Clamp meter
Voltage
Temperature : Thermo couple
CM-211 CM-113
Humidity : Dedicated humidity sensor
Wide 500 V range is provided for voltage input, so it corresponds 100 to 200 V AC power supply waveform measurement.Also, using with the logic input and clamp meters, power supply voltage and current and the sequence control can be measured as the same time.
When input each signal as voltage, it is possible to convert to original unit using the unit conversion function
Clamp meter
Max. sampling 10 sec with all channels simultaneous sampling A/D resolution is 16 bit high resolution
High speed 8ch simultaneous sampling with 16 bit high resolution
8
12
14
16
Storage Oscilloscope
100M 1M 10K 10
Data logger GL900
Memory recorder
Sampling speed (S/s)
A/D
resolu
tion
(b
it)
1K 20M
Temperature Dynamic characteristics Control signal
Circuit signal
Speed-up
Hig
h
resolu
tion
Signal
100K
Storage destination 10 s 100 s 500 s 1ms 10ms 100ms 1s 1min
64 MB internal memory Yes Yes Yes Yes Yes Yes Yes Yes
256MB internal Flash
memory
No No No Yes Yes Yes Yes Yes
USB memory No No No Yes Yes Yes Yes Yes
Corresponding to various measurement sceneCorresponding to various measurement scene
Capture destination
10μs 100μs
500μs 1ms 10ms 100ms 1s
Internal RAM(1 million point max.)
10 sec
100 sec
8 min20 sec
16 min40 sec
2 hours46 min
1 day3 hours
11 days13
hours
256 MB internal flash memory
× × × 11 hours 4 days 49 days493 days
512 MB USB memory
× × × 22 hours 8 days 98 days986 days
Application・ Drop down test・ Shock test・ Vibration test
Application・ Durability test・ Tension/Compression test・ Environment test
High speed phenomena such as the drop down test and the mechanical shock test can be measured with 1ms or faster high speed sampling then stored to internal RAM for max. 1 million points. Also all channels are simultaneously sampled without time difference between channels, it is possible to check the correlation of each parts.Further more, 1ms to 1min slow sampling is for the durability test, and large size 256MB internal flash memory or external USB memory can store long time measurement.
・ Bright and easy-to-read, Large size 5.7 inch color LCD ・ Simple setting operation by cursor keys ・ High speed waveform can be enlarged or reduced, Oscilloscope like operation
Large size 5.7 inch color LCD for bright and easy-to- read waveform display
Simple setting operation by cursor keys
Easy-to-read large size 5.7 inch color TFT LCD
Magnifying of time axis
Compression of time axis
TIME/DIV key
10ms/ DIV to
1 min / DIV
Previously, measurement equipment needs to record the input signal once to confirm the waveform before start measurement.But the GL series installs the free running display function, so the input signal is displayed on the screen soon after power on, you can check the input signal soon, and easily set the measurement condition within short period of time.
Easy setting operation with Easy setting operation with the free running display functionthe free running display function
Previous models
Press START key to start measurement,check the input signal and press STOP key
Set input range
Press START key again to start measurement,check the input signal and press STOP key
Press START key to start actual measurement
If necessary, repeat above steps
Check input signal by free running display
Set the input range
Press START key for actual measurement
GL900
Waveform display area
Waveform is displayed during setting for easy operation
TIME/DIV, Position and Span setting can be done in the free running display
Display scrollMax..: 10ms/DIV
Following two file formats are selectableGBD (Graphtec binary data) format : data size is smaller than CSV formatCSV format : You can open it by Excel or other software without using any dedicated software
The USB memory can be used as the external memory device.If you specify the USB memory as the capture destination, the data is directly stored to the USB memory.Also, for the long time measurement such as the durability test, you can measure it just by use the USB memory which has necessary data capacity.The transfer to PC is also possible just by insert the USB memory to the PC.* The max. file size for measurement data is 2GB. Please use standard type USB memory which does not support the functions such as the finger print recognition.
Data can be stored to USB memory Data can be stored to USB memory which easily can be connected to the PCwhich easily can be connected to the PC
External USB memory terminal
Data can be transferred to the PC easily.
Using the combination of trigger function and timer function, only necessary data can be stored without capturing wasted data.
Wealth of trigger and timer function
Jan. 1 Jan. 5 Jan. 10 Jan. 15 Jan. 20 Jan. 25 Jan. 30
Timer Mode : Day/Time Start Settings : Date 2008 – 01-10 Time 00 : 00Start Settings : Date 2008 – 01-14 Time 23 : 59
Trigger Settings Start Source : OffStop Source : Off
Timer Settings
Timer Mode Off , Day/Time , Daily , Hourly
Trigger Settings
Start Source Off , Level , Ext.
Stop Source Off , Level , Ext. , Time
Pre Trigger 0 to 100 %
Repeat measurement On/Off and repeat interval
: Data capture
: Timer is activated
Example 1 : When measure 4 days from Jan. 10
Only when the capturing
destination is internal RAM
Start key On
Wealth of trigger and timer function
00 :00 04 :00 08 : 00 12 : 00 16 : 00 20 : 00 24 : 00
Timer Mode : OffTrigger Settings Start Source : Off
Stop Source : TimeTime Settings : 1 h 00 min 00 sec
Repeat : OnRep. int. : 0004 h 00 min
: Data capture
Example 3 : When measure 1 hour in 4 hours interval every day
Repeat interval is counted from the time
when trigger is activated
Repeat interval : 4 hours
00 : 00 12 : 00 00 : 00 12 : 00 00 : 00
Start Trigger : 3V
Stop Trigger : 2V
Timer Mode : Daily Start Settings : 09 : 00Stop Settings : 17 : 00
Trigger Settings Start Source : LevelLevel Settings : CH1 , Mode : H , Level : 3 V
Stop Source: LevelLevel Settings : CH1 , Mode: L , Level : 2 V
Repeat : On
5V
0 V
: Data capture
: Timer is activated
Example 2 : When measure abnormal signal of equipment during working time
: Trigger point Measurement finishes by the priority for timer
setting
Start key On
Start key On
Wealth of trigger and timer function
00:00 01:00 02:00 03:00 04:00 05:00 06:00
5V
0V
: Data capture
: Timer is activated
Example 4 : When measure for 20 minutes in every hour
00:00 01:00 02:00 03:00 04:00 05:00 06:00
Start Trigger 3V
Stop Trigger 2V
5V
0V
Example 5 : When measure only abnormal signal within 20 minutes of every hour
Measurement stops by the priority for
timer setting
Start key On
Start key On
Timer Mode : Hourly Start Settings : 00 min 00 secStart Settings : 20 min 00 sec
Trigger Settings Start Source : OffStop Source : Off
: Data capture
: Timer is activated
: Trigger point
Timer Mode : Hourly Start Settings : 00 min 00 secStop Settings : 00 min 20 sec
Trigger Settings Start Source : LevelLevel Settings : CH1 , Mode : H , Level : 3 V
Stop Source: LevelLevel Settings : CH1 , Mode: L , Level : 2 V
Repeat : On
Possible to use as X-Y recorderPossible to use as X-Y recorder Duplicating the X-Y recorder’s action.Pen up/down action is duplicated, so it is possible to use like an analog X-Y recorder.Corresponding to Max. 4 pen X-Y recorder.Also, the data is digital format, so you can easily check the data and create the report after finish the measurement.
Point moves as if pen moves If capturing the screen copy then paste on the Excel, you can use it as report.
Pen moving can be checked with pen-up condition
Waveform is displayed by pen-down. Data capture starts
by measurement start.
After finish measurement, data can be check by digital
value using cursor.
NTP server Ethernet
The GL900’s time can be synchronized to the NTP server’s time at periodic intervals. ( NTP : Network Time Protocol )
Setting, control and data can be transferred without using the standard attached software
Ethernet
FTP client function
The data captured to the GL900’s internal memory or the USB memory stick can be automatically backed up to the FTP server at fixed intervals
USB drive mode
USB drive mode is a fast and easy way to transfer data from internal memory to an external computer
NTP client server function
WEB server function
Waveform display and GL900 settings can be made via a web browser such as Internet Explorer
Ethernet USB
USB DRIVEMODE
USB and Ethernet is provided as standard (dedicated PC software is attached)Using USB dive mode, WEB server and FTP server function, you can transfer the data to PC, and control and setting of GL900 from PC is possible.
Remote control and data transfer is possible
Ethernet / USB USB I/F
Ethernet I/F
Item Description
Number of input channels 8ch
Type of input terminal BNC and M3 Screw type terminal
Method All channels isolated, Simultaneous sampling
Measurement range
Voltage 20mV to 500V / F.S. (Between + and – terminals, 500 V p-p max.)
Temperature Thermocouple: K, J, E, T, R, S, B, N, W(WRe5-26)
Humidity 0 to 100% ( When using optional B-530 humidity sensor is used )
External input /
output
Input Trigger: 1ch, Selectable between pulse and Logic: 4ch
Output Alarm: 4ch
A / D converter 16bit(out of which 14 are internally acknowledged)
Maximum sampling interval 10 micro-second
Internal memory size RAM : 1 million data, 256MB Flash memory
External memory USB memory (1 file 2 GB)
Calculation function Statistics calculation, Searching function
Display 5.7 inch TFT color LCD
Interface to PC Ethernet ( 10BASE-T / 100BASE-TX ) , USB (Compatible with full speed)
Operating environmentTemperature : 0 to 40 (15 to 40 when operating by battery ) , Humidity : 5℃ ℃ ~ 85 % R.H.
Power supplyAC adapter ( 100 to 240V AC ,50 to 60Hz ) , DC input ( 8.5 to 24V DC)Battery pack : 2 batteries installable
External dimensions (approx.) 232W x 150H x 80D mm
Weight (approx.) 1.1kg ( Excluding the AC adapter and battery )
Vibration resistance Compatible with JIS Vibration testing methods for automobile Type 1 Class A-equivalent
GL900 Specifications
Accessories Accessories
Item Model Remark
Battery pack B-5172 batteries need to be installed when operate
Logic alarm cable B-513 2m
DC power cable B-514 2m
Humidity sensor B-530 3m
Safe probe RIC-141 1:1 , 42pF
BNC – BNC cable RIC-112 1.5m
BNC – Banana cable RIC-113 1.5m
BNC –Alligator Clip cable RIC-114 1.5m