ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on...

22
2 1 7 3 6 5 4 8 10 9 ISO CLIP Jan 2015 DET-00 STANDARD VERTICAL DETAILS

Transcript of ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on...

Page 1: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

2

1

7

3

6

5

4

8

10

9

ISO CLIP

Jan 2015

DET-00STANDARD VERTICAL DETAILS

Page 2: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

#14 -14 x 2"HWH SD #3(AS REQUIRED)

FIXING & ADJUSTINGFASTENERS

#10 x 5 8" HWH SD #2(AS REQUIRED)

ISO CLIP

INTERGRALTHERMALISOLATOR

GALVANIZEDANGLE

PANEL DEPTH VARIABLE INSULATION DEPTH

4" - 6"

TYPICAL PANELSYSTEM

ISO CLIP

Jan 2015

DET-01SECTIONAL DETAIL

W/ VERTICAL BARS ON SHEATHING

Page 3: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

FIXING & ADJUSTINGFASTENERS#10 x 5 8" HWH SD #2(AS REQUIRED)

GALVANIZED ANGLE

#14 -14 x 2" HWH SD #3(AS REQUIRED)

ISO CLIP

SHEATHING ONMETAL STUDS

INTERGRAL THERMAL ISOLATOR

PAN

EL D

EPTH

VA

RIA

BLE

INSU

LATIO

N D

EPTH

4" -

6"

TYPICAL PANEL SYSTEM

AIR / VAPOUR BARRIER

ISO CLIP

Jan 2015

DET-02PLAN DETAIL

W/ VERTICAL BARS ON SHEATHING

Page 4: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

GALVANIZEDANGLE

FIXING & ADJUSTINGFASTENERS

#10 x 5 8" HWH SD #2(AS REQUIRED)

ISO CLIP

INTERGRALTHERMALISOLATOR

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

#14 -14 x 2"HWH SD #3(AS REQUIRED)

PANEL DEPTH VARIABLE INSULATION DEPTH

4" - 6"

TYPICAL PANELSYSTEM

ISO CLIP

Jan 2015

DET-03HEAD DETAIL

W/ VERTICAL BARS ON SHEATHING

Page 5: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

GALVANIZEDANGLE

ISO CLIP

INTERGRALTHERMALISOLATOR

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

FIXING & ADJUSTINGFASTENERS

#10 x 5 8" HWH SD #2(AS REQUIRED)

#14 -14 x 2"HWH SD #3(AS REQUIRED)

PANEL DEPTH VARIABLE INSULATION DEPTH

4" - 6"

TYPICAL PANELSYSTEM

ISO CLIP

Jan 2015

DET-04SILL DETAIL

W/ VERTICAL BARS ON SHEATHING

Page 6: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

INTERGRAL THERMALISOLATOR

ISO CLIP

FIXING & ADJUSTINGFASTENERS

#10 x 5 8" HWH SD #2(AS REQUIRED)

PAN

EL D

EPTH

VA

RIA

BLE

INSU

LATIO

N D

EPTH

4" -

6"

#14 -14 x 2" HWH SD #3(AS REQUIRED)

TYPICAL PANELSYSTEM

GALVANIZED ANGLE

ISO CLIP

Jan 2015

DET-05JAMB DETAIL

W/ VERTICAL BARS ON SHEATHING

Page 7: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

GALVANIZEDANGLE

FIXING & ADJUSTINGFASTENERS

#10 x 5 8" HWH SD #2(AS REQUIRED)

ISO CLIP

INTERGRALTHERMAL ISOLATOR

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

#14 -14 x 2"HWH SD #3(AS REQUIRED)

PANEL DEPTH VARIABLE INSULATION DEPTH

4" - 6"

TYPICAL PANELSYSTEM

ISO CLIP

Jan 2015

DET-06BASE DETAIL

W/ VERTICAL BARS ON SHEATHING

Page 8: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

ISO CLIP

INTERGRALTHERMAL ISOLATOR

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

FIXING & ADJUSTINGFASTENERS

#10 x 5 8" HWH SD #2(AS REQUIRED)

#14 -14 x 2"HWH SD #3(AS REQUIRED)

PANEL DEPTH VARIABLE INSULATION DEPTH

4" - 6"

TYPICAL PANELSYSTEM

GALVANIZEDANGLE

ISO CLIP

Jan 2015

DET-07PARAPET DETAIL

W/ VERTICAL BARS ON SHEATHING

Page 9: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

INTERGRAL THERMALISOLATOR

#14 -14 x 2" HWH SD #3(AS REQUIRED)

ISO CLIP

GALVANIZED ANGLE

FIXING & ADJUSTINGFASTENERS

#10 x 5 8" HWH SD #2(AS REQUIRED)

PAN

EL D

EPTH

VA

RIA

BLE

INSU

LATIO

N D

EPTH

4" -

6"

TYPICAL PANELSYSTEM

ISO CLIP

Jan 2015

DET-08END DETAIL

W/ VERTICAL BARS ON SHEATHING

Page 10: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

#14 -14 x 2" HWH SD #3(AS REQUIRED)

GALVANIZED ANGLE

INTERGRAL THERMAL ISOLATOR

FIXING & ADJUSTINGFASTENERS

#10 x 5 8" HWH SD #2(AS REQUIRED)

PAN

EL D

EPTH

VA

RIA

BLE

INSU

LATIO

N D

EPTH

4" -

6"

TYPICAL PANEL SYSTEM

ISO CLIP

ISO CLIP

Jan 2015

DET-09INSIDE CORNER

W/ VERTICAL BARS ON SHEATHING

Page 11: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

(2) #14 -14 x 2"HWH SD #3

(AS REQUIRED)

INTERGRALTHERMAL ISOLATOR

ISO CLIP

FIXING & ADJUSTINGFASTENERS#10 x 5 8" HWH SD #2(AS REQUIRED)

GALVANIZEDANGLE

SHEATHING ONMETAL STUDS

AIR / VAPOURBARRIER

PANEL DEPTHVARIABLE INSULATION DEPTH

4" - 6"

TYPICAL PANELSYSTEM

ISO CLIP

Jan 2015

DET-10OUTSIDE CORNER

W/ VERTICAL BARS ON SHEATHING

Page 12: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

2

1

7

3

6

5

4

8

10

9

ISO CLIP

Jan 2015

DET-00STANDARD HORIZONTAL DETAILS

Page 13: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

TYPICAL PANELSYSTEM

#14 -14 x 2"HWH SD #3(AS REQUIRED)

ISO CLIP

GALVANIZED ANGLE

AIR / VAPOURBARRIER

INTERGRALTHERMALISOLATOR

SHEATHING ONMETAL STUDS

PANEL SUPPORTCLIP

FIXING & ADJUSTINGFASTENERS

#10 x 5 8" HWH SD #2(AS REQUIRED)

PANEL DEPTH VARIABLE INSULATION DEPTH

4" - 6"

ISO CLIP

Jan 2015

DET-01SECTIONAL DETAIL

W/ HORIZONTAL BARS ON SHEATHING

Page 14: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

GALVANIZEDANGLEFIXING & ADJUSTING

FASTENERS#10 x 5 8" HWH SD #2

(AS REQUIRED)TYPICAL PANELSYSTEM

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

INTERGRALTHERMAL ISOLATOR

ISO CLIP

#14 -14 x 2" HWH SD #3(AS REQUIRED)

PAN

EL D

EPTH

VA

RIA

BLE

INSU

LATIO

N D

EPTH

4" -

6"

ISO CLIP

Jan 2015

DET-02PLAN DETAIL

W/ HORIZONTAL BARS ON SHEATHING

Page 15: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

GALVANIZED ANGLE

FIXING FASTENER#10 x 5 8" HWH SD #2

(AS REQUIRED)

ISO CLIP

INTERGRALTHERMALISOLATOR

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

TYPICAL PANEL SYSTEM

PANEL DEPTH VARIABLE INSULATION DEPTH

4" - 6"

#14 -14 x 2" HWH SD #3(AS REQUIRED)

ISO CLIP

Jan 2015

DET-03HEAD DETAIL

W/ HORIZONTAL BARS ON SHEATHING

Page 16: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

GALVANIZED ANGLE

ISO CLIP

#14 -14 x 2"HWH SD #3(AS REQUIRED)

INTERGRALTHERMALISOLATOR

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

TYPICAL PANELSYSTEM

FIXING FASTENER#10 x 5 8" HWH SD #2

(AS REQUIRED)

PANEL DEPTH VARIABLE INSULATION DEPTH

4" - 6"

ISO CLIP

Jan 2015

DET-04SILL DETAIL

W/ HORIZONTAL BARS ON SHEATHING

Page 17: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

INTERGRAL THERMALISOLATOR

ISO CLIP

FIXING & ADJUSTINGFASTENERS

#10 x 5 8" HWH SD #2(AS REQUIRED)

#14 -14 x 2"HWH SD #3

(AS REQUIRED)

GALVANIZEDANGLE

PAN

EL D

EPTH

VA

RIA

BLE

INSU

LATIO

N D

EPTH

4" -

6"

TYPICAL PANEL SYSTEM

ISO CLIP

Jan 2015

DET-05JAMB DETAIL

W/ HORIZONTAL BARS ON SHEATHING

Page 18: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

GALVANIZEDANGLE

FIXING FASTENER#10 x 5 8" HWH SD #2

(AS REQUIRED)

ISO CLIP

#14 -14 x 2"HWH SD #3

(AS REQUIRED)

INTERGRALTHERMALISOLATOR

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

PANEL DEPTH VARIABLE INSULATION DEPTH

4" - 6"

TYPICAL PANELSYSTEM

ISO CLIP

Jan 2015

DET-06BASE DETAIL

W/ HORIZONTAL BARS ON SHEATHING

Page 19: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

GALVANIZED ANGLE

ISO CLIP

#14 -14 x 2"HWH SD #3(AS REQUIRED)

INTERGRALTHERMALISOLATOR

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

TYPICAL PANELSYSTEM

FIXING FASTENER#10 x 5 8" HWH SD #2

(AS REQUIRED)

PANEL DEPTH VARIABLE INSULATION DEPTH

4" - 6"

ISO CLIP

Jan 2015

DET-07PARAPET DETAIL

W/ HORIZONTAL BARS ON SHEATHING

Page 20: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

GALVANIZED ANGLE

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

FIXING & ADJUSTINGFASTENERS#10 x 5 8" HWH SD #2(AS REQUIRED)

INTERGRAL THERMAL ISOLATOR

#14 -14 x 2" HWH SD #3(AS REQUIRED)

ISO CLIP

PAN

EL D

EPTH

VA

RIA

BLE

INSU

LATIO

N D

EPTH

4" -

6"

TYPICAL PANEL SYSTEM

ISO CLIP

Jan 2015

DET-08END DETAIL

W/ HORIZONTAL BARS ON SHEATHING

Page 21: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

TYPICAL PANELSYSTEM

AIR / VAPOURBARRIER

SHEATHING ONMETAL STUDS

FIXING & ADJUSTINGFASTENERS#10 x 5 8" HWH SD #2(AS REQUIRED)

INTERGRALTHERMAL ISOLATOR

ISO CLIP

#14 -14 x 2"HWH SD #3

(AS REQUIRED)

GALVANIZED ANGLE

PAN

EL D

EPTH

VA

RIA

BLE

INSU

LATIO

N D

EPTH

4" -

6"

ISO CLIP

Jan 2015

DET-09INSIDE CORNER

W/ HORIZONTAL BARS ON SHEATHING

Page 22: ISO CLIP DET-00 · 2016. 8. 30. · iso clip jan 2015 det-07 parapet detail w/ vertical bars on sheathing. air / vapour barrier sheathing on metal studs intergral thermal isolator

#14 -14 x 2" HWH SD #3(AS REQUIRED)

INTERGRAL THERMALISOLATOR

ISO CLIP

FIXING & ADJUSTINGFASTENERS

#10 x 5 8" HWH SD #2(AS REQUIRED)

TYPICALPANEL SYSTEM

GALVANIZEDANGLE

PAN

EL D

EPTH

VA

RIA

BLE

INSU

LATIO

N D

EPTH

4" -

6"PANEL DEPTHVARIABLE INSULATION DEPTH

4" - 6"

AIR / VAPOURBARRIER

ISO CLIP

Jan 2015

DET-10OUTSIDE CORNER