Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

18
Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto
  • date post

    20-Dec-2015
  • Category

    Documents

  • view

    216
  • download

    1

Transcript of Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Page 1: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Irradiation Sample Transfer Line Snubbing Section BehaviorGreg Padilla and Keane Nishimoto

Page 2: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Introduction

BackgroundThe MIT reactor and Transfer Line

MotivationSafety measure in case of Transfer

Line failure Desired Findings

Model to help design snubbing section

Page 3: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Procedure

Apparatus Experimental Procedure Data Processing

Page 4: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

ApparatusSmoothSectionW/ Bend

First Sensor

Snubbing Section

PressureSensor

SecondSensor

TransferCylinder

Transfer line

Page 5: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Experimental Procedure

Calibration of pressure sensor Drops at 4 heights for each of 3

different masses Data Recorded

Page 6: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Data Processing

Calibration data Capsule velocity calculated Pressure calculations

Page 7: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Typical Data from Drop Test

Data taken form container mass = 0.7kg

Height = 42” inches

Page 8: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Data

Trigger Trace from first sensor

Trace from second sensor Trace from Pressure

sensor

Page 9: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Theoretical Analysis

Model of the falling capsuleTransfer LineSnubbing Section

MATLAB Simulation

Page 10: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Transfer Line Model

The capsule is a falling object

Page 11: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Snubbing Section Model

Force due to gravity Force due to pressure

Ideal Gas Law – PV=mRTNavier Stokes

Used to determine the mass of air left

2h

hdxdP

12μ1

ρAm 3

cair

Page 12: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.
Page 13: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

MATLAB simulation

ODE 23 solver State Variables

Position and velocity of capsuleMass of air in snubbing section

Page 14: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Results

Page 15: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Smooth Section Model

Velocity is independent of Mass Velocity is a Function of Height Velocity = 1.46*Height + 2.18 Ave. Error of 16%

Velocity as a Function of Mass

3

3.5

4

4.5

5

5.5

300 500 700 900

Mass [g]

Vel

ocity

[m/s

ec]

height=1.07 m

height=0.72 m

height=1.73 m

Exp. Data and Therical models

2

2.5

3

3.5

4

4.5

5

0.5 1 1.5 2

Height [m]

Vel

ocity

[m/s

ec]

Exp. data

Gravity Model

Page 16: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Snubbing Section Model

Initial Conditions: Mass = 0.7kg Velocity = 4.0m/s Temperature = 298K

Page 17: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Recommendations

Temp = 574K Velocity = 5.0m/s Snubbing Length

=1.5m Max P=1.81kPa Snubbing Length

=1.0m Max P=1.86kPa

Page 18: Irradiation Sample Transfer Line Snubbing Section Behavior Greg Padilla and Keane Nishimoto.

Final

Temp = 574K Velocity = 5.0m/s Snubbing Length

=1.3m Max P=1.83kPa