IPEmotion 2017 R3 – General changes

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 2/ 26

Table of contents

1 IPEmotion 2017 R3 – General changes .................................................................................................. 3

1.1 PlugIns included in the Setup ............................................................................................................ 3

1.2 Supported Languages in the Setup ................................................................................................... 3

1.3 TEDS Editor to define new sensors ................................................................................................... 3

2 New functions in OPTIONS ..................................................................................................................... 6

2.1 Clipboard function for license dialog .................................................................................................. 6

2.2 Unit frame rate ................................................................................................................................... 6

3 New functions in SIGNALS ...................................................................................................................... 7

3.1 Synchronization of description file on name level only ...................................................................... 7

3.2 DBC files supporting initial values for CAN send............................................................................... 9

3.3 Event controlled signal selection for DBC import ............................................................................ 10

3.4 FlexRay signals with Multiplexer ..................................................................................................... 12

3.5 Address extension parameter for CCP measurement ..................................................................... 13

4 New functions in VIEW .......................................................................................................................... 14

4.1 Reset of time axis in Yt-chart for storage events ............................................................................. 14

4.2 Alphanumerical instrument with settings for individual font size ..................................................... 16

4.3 Edit min/max scaling for joint Y-axis ................................................................................................ 17

4.4 Table instrument with responsive minimum font size ...................................................................... 18

5 New functions in DATA MANAGER ...................................................................................................... 19

5.1 PlugIn for user specific postprocessing operations ......................................................................... 19

5.2 BLF traffic data import format .......................................................................................................... 21

5.3 Correction factor settings for FFT and Campbell operation ............................................................ 22

5.4 Relative results for sample count classifications ............................................................................. 22

6 New functions in ANALYSIS ................................................................................................................. 23

6.1 Offline traffic filter operation ............................................................................................................. 23

6.2 Yt-chart with graph style display mode ............................................................................................ 24

IPEmotion 2017 R3 – General changes

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 3/ 26

1 IPEmotion 2017 R3 – General changes

1.1 PlugIns included in the Setup

IPEmotion PlugIn IPETRONIK CAN V01.16.00

IPEmotion PlugIn IPETRONIK LOG V03.59.01

IPEmotion PlugIn IPETRONIK X V02.05.02

IPEmotion PlugIn Protocols V02.00.00

IPEmotionPlugin Video V01.01.01

IPEmotionPlugin GPS V01.05.00

1.2 Supported Languages in the Setup

English

German

1.3 TEDS Editor to define new sensors

With the TEDS Editor Tool you can update and create new TEDS parameters of your sensors. The following drawing shows the system architecture.

IPETRONIK is offering TEDS interfaces suitable for the different LEMO 10-pole, 7-pole und 6-pole sensor input cables.

IPEmotion 2017 R3 – General changes

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 4/ 26

The new function of the TEDS Editor tool is that sensor can be created from scratch.

When you create a new sensor, you can select from the following 3 templates. The drop dow list of the physical measurement ranges are related to selected template types above.

High Level Voltage Outout Sensor

Accelerometer and Force Transducer

Current Loop Output Sensor

The screenshot blow shows a new created sensor. IPETRONIK is registered officially as a TEDS sensor manufacturer.

IPEmotion 2017 R3 – General changes

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 5/ 26

When you create a new sensor, detect the data of a sensor, or load a TEDS binary configuration file most of the data fields are editable as indicated below via the red dots. Some field are not editable for all sensor. Some of the fields are not editable depending on the selected template type.

New functions in OPTIONS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 6/ 26

2 New functions in OPTIONS

2.1 Clipboard function for license dialog

Th license dialog is supporting the function to past license from the clipboard directly into the licenses dialog. The button “read from clipboard” is only visible when a license code is stored in the clipboard.

2.2 Unit frame rate

The unit frame rate was introduced to adapt the settings and unit conversion to different frame rates per seconds, minutes or hours.

New functions in SIGNALS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 7/ 26

3 New functions in SIGNALS

3.1 Synchronization of description file on name level only

You can use the description file synchronization function to compare your existing measurement configuration against a new description file. The description file synchronization is useful to get a direct view about the differences between a new ECU description file and your current measurement configuration. In the standard setup the description file is compared on Message ID and channel name.

New functions in SIGNALS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 8/ 26

When one of the two parameters is different, the synchronization will not take place and you will get a notification in the message window. The standard synchronization behavior can cause an additional workload when e.g. a channel is switched to a different message because then the synchronization does not take place and the related links to the VIEW instruments and formulas or storage in ACQUISITION work space etc. is removed as well.

With the new EXPERT setting “Synchronize signals by name” the synchronization mechanism is focusing only on the channel name and not any more on the message ID. The benefit for the user is that the synchronization will take place and the links to the VIEW instruments etc. remain intact to display online data. The screenshot below in indicating on the right-hand side, that the channel “Exhaust_1” was successfully synchronized even so that it is included on a different CAN message ID.

Information The EXPERT settings are may stored in the IWF file if you activate the check box

in FREQUENTLY USED > Include Options in configuration”.

New functions in SIGNALS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 9/ 26

3.2 DBC files supporting initial values for CAN send

When a DBC file includes initial values for CAN message sending, the start values can be imported and displayed.

The initial value becomes only active and visible when the data format is configured in the format tab sheet to output.

New functions in SIGNALS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 10/ 26

3.3 Event controlled signal selection for DBC import

The description file import dialog offers in the channel grid a new configuration function. In the signal grid you can use the column chooser to add a new channel property to the grid which is called Cyclic.

Within the Cyclic column you can switch the measurement mode of all signals included in a CAN message to event controlled or to cyclic operation.

New functions in SIGNALS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 11/ 26

The settings from the import dialog regarding measurement mode is also reflected in the column sample rate in the channel grid as indicated below.

New functions in SIGNALS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 12/ 26

3.4 FlexRay signals with Multiplexer

The import of FIBEX files is supporting multiplex signals.

New functions in SIGNALS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 13/ 26

3.5 Address extension parameter for CCP measurement

The A2L import for CCP measurement is supporting additional information to indicate the address extension type.

New functions in VIEW

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 14/ 26

4 New functions in VIEW

4.1 Reset of time axis in Yt-chart for storage events

In the VIEW section of the options dialog you can configure an automatic reset of the relative time axis in an Yt-chart. In the default behavior you may start your data display and execute the storage operation some time later. In this case the Yt-chart keeps plotting the relative time and it is not visible at what point in time the data storage activated.

When you activate the function “Reset relative time on each start of storage” in the VIEW options the display behavior of a storage event will change.

New functions in VIEW

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 15/ 26

In this case if you run the display of data for some time and you execute the storage button from the ribbon, the diagrams sets the relative time axis for the storage event to zero.

Information

The reset of the time axis is only functional when you operate the storage button

from the ribbon. When you execute the data storage from trigger events the

Yt-chat time axis is not affected.

New functions in VIEW

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 16/ 26

4.2 Alphanumerical instrument with settings for individual font size

The alphanumerical display is supporting a new font size configuration setting. In the per-channel mode the font size of each channel will be individually set to the available space in the instrument container. The setting is considering the number of decimal places configured in the display tab sheet in the SIGNALS workspace. Text channels are considered in the size calculation with the decimal format “Automatic”. All numeric or text channels with automatic decimal place configuration will get the same font size.

New functions in VIEW

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 17/ 26

4.3 Edit min/max scaling for joint Y-axis

For diagrams with joint Y-channel axis the min and max display range is commonly configured for all channels associated to the Y-axis in the head-up display.

VIEW instruments Yt-chart, xy-chart & FFT, Oscilloscope

ANALYSIS instruments: Yt-chart, xy-chart & FFT, Polar diagram

New functions in VIEW

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 18/ 26

4.4 Table instrument with responsive minimum font size

The table instrument in the VIEW and ANALYSIS work space is respecting a minimum font size for small application windows to ensure good readability for the user.

In the past the font size was scaled down accordingly to the application window size, the channel names and data in the table instrument was getting unreadable in the case of very small applications windows.

New functions in DATA MANAGER

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 19/ 26

5 New functions in DATA MANAGER

5.1 PlugIn for user specific postprocessing operations

The PlugIn concept is also available for post processing operations. The PlugIn interfaces allows every developer to include his individual post processing operations in the DATA MANAGR work spaces. In order to install the user Operation PlugIn documentation you have to include the SDK package during installation.

The manual is installed in the following directory:

C:\Program Files (x86)\IPETRONIK\IPEmotion 2017 R3\UOP

Information In order to develop a user operation PlugIn you need to obtain an official

manufacturer code for your PlugIn.

New functions in DATA MANAGER

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 20/ 26

When you have installed the demo user operation PlugIn you will get additional analysis operations function in the DATA MANAGER as indicated below.

New functions in DATA MANAGER

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 21/ 26

5.2 BLF traffic data import format

The data import formats are extended. BLF traffic files for CAN, CAN FD und FlexRay traffic are supported. The import of IPEmotionRT data files is coving the new format from new LINUX based data loggers.

BLF traffic (CAN, CAN FD und FlexRay)

IPEmotionRT

New functions in DATA MANAGER

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 22/ 26

5.3 Correction factor settings for FFT and Campbell operation

The FFT and Campbell operation is supporting for the different window function predefined correction actors.

5.4 Relative results for sample count classifications

The sample count and sample count compound classification can display the results also in percent based on all samples counted. In the case that some samples are outside your defined boundaries the calculated percentage will not add up to 100%.

New functions in ANALYSIS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 23/ 26

6 New functions in ANALYSIS

6.1 Offline traffic filter operation

The offline traffic analyzer is supporting extended filter functions

For the traffic filter configuration, the same functions are available as for online traffic filter measurement.

Create filers from DBC file by selecting specific messages

Define filter manually

New functions in ANALYSIS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 24/ 26

6.2 Yt-chart with graph style display mode

In the head up display of the Yt-chart you can select different graph styles. With the graph style you have an impact on how the graph line will be plotted between the connecting data points.

New functions in ANALYSIS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 25/ 26

The impact of the different graph styles will be presented below.

Automatic In this line style mode the default behavior is reflected. When you zoom into the data, at a certain high zoom level the data points appear and the and the data points are connected in a step line type.

Linear In this mode the graph will show on all high and low zoom levels only a line and no data points.

New functions in ANALYSIS

IPEmotion Release News 2017 R3 IPETRONIK GmbH & Co. KG ipetronik.com 26/ 26

Steps In this mode you get at all zoom levels a step type line presentation between the data points.