Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of...
Transcript of Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of...
![Page 1: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/1.jpg)
Click to edit Master title style
SOLUTIONS FOR THE BUILT WORLD
Fall 2015 Iowa DOT Vibration Seminar
Pre‐Construction Surveying: Techniques and Examples
Nathaniel S. [email protected]
![Page 2: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/2.jpg)
Iowa DOT Specifications
![Page 3: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/3.jpg)
Special Provisions for Pre‐Blast Crack and Damage Survey Visually inspect and recording all existing defects in the identified structures
Special Provisions for Vibration Monitoring (to Protect Historic Structures) Develop a plan which minimizes the potential for vibration damage due to construction and demolition activities
Monitor vibrations and crack behavior at the identified structures to protect them from vibration induced damage
Iowa DOT Specifications
![Page 4: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/4.jpg)
Special Provisions
Identified Structures
![Page 5: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/5.jpg)
Pre‐Construction Condition Survey Professional Engineer (State of Iowa) experienced in evaluating structural vulnerabilities and vibration monitoring
List of prequalified firms– Exponent (Wood Dale, IL)– Klienfelder East (Omaha, NE)– WJE (Northbrook, IL)– Terracon Consultants (Des Moines, IA)
The Contractor is responsible for arranging with the property owner the rights‐of‐entry to their property in order to engage in condition surveys, vibration monitoring, and crack monitoring
Special Provisions
![Page 6: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/6.jpg)
Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches, photographs, and any other data the preparer may deem appropriate.
Evaluation of the risk from construction vibrations
Photos and plan sketches indicating existing vulnerabilities
Special Provisions
![Page 7: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/7.jpg)
Monitoring Plan Description of monitoring/communications equipment, alarm notification system
Description of post‐alarm survey in the event of a PPV threshold exceedence
Requires daily activity log of vibration activity and crack monitors
Daily testing and logging of entire seismograph/communications network
Construction methods and equipment chosen to achieve low project vibration levels Contractor
Special Provisions
![Page 8: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/8.jpg)
Equipment Installation and Monitoring Program Crack monitoring Vibration monitoring Elevation or positional surveying Building tilt monitoring Subsurface inclinometer
Special Provisions
![Page 9: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/9.jpg)
Vibration Limits PPV level shall be determined by a qualified expert in the field of vibration monitoring
In no case shall the PPV level exceed 0.2 inches/second [ips] as measured at or in very close proximity to the monitored structure
Alarmed monitoring system shall signal any vibration event that equals or exceeds a thresholdof 80% of the PPV Limit
Immediately cease work if the alarm at the structure indicates the threshold is exceeded
Alternative construction methods will be used if the PPV Limit is exceeded
Special Provisions
![Page 10: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/10.jpg)
Post‐Construction Survey and Report Determine if any structural changes are the result of the construction activity
Basis For Payment Lump sum cost
Special Provisions
![Page 11: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/11.jpg)
Condition Surveying
![Page 12: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/12.jpg)
Notify building owners/occupants Contractor or Iowa DOT representative Iowa DOT letter of explanation
“In order to make this successful, we ask for your participation by allowing the specialized firm access to your building to complete the necessary condition surveys and vibration monitoring. As an owner, you do have the right to deny access to the Contractor, but we do not feel denial would benefit any party.”
Schedule inspection Time needed varies widely
General Procedures
![Page 13: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/13.jpg)
Perform Preconstruction Survey Assess vulnerabilities of subject property
– Building system and materials
– Distance to construction work Assess and document condition
– Visual inspection
– Document observed distress (vibration sensitive)– High resolution photographs, video
– Measure select conditions (crack widths, offset, existing settlement)
Secondary Purposes– Answering homeowner questions
– Correcting sensitive conditions prior to start of construction
General Procedures
![Page 14: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/14.jpg)
Develop survey report and monitoring plan Submitted to Contractor
Solicit review by Contractor and IowaDOT
General Procedures
![Page 15: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/15.jpg)
Data Presentation Methods
![Page 16: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/16.jpg)
Photograph/Video Logs
![Page 17: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/17.jpg)
Photograph/Video Logs
![Page 18: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/18.jpg)
Photograph/Video Logs
![Page 19: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/19.jpg)
Condition Documentation ‐ Drawings
![Page 20: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/20.jpg)
Condition Documentation ‐ Drawings
![Page 21: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/21.jpg)
Condition Documentation ‐ Sketches
![Page 22: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/22.jpg)
Condition Documentation ‐ Sketches
![Page 23: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/23.jpg)
Condition Documentation ‐ Sketches
![Page 24: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/24.jpg)
Condition Documentation ‐ Sketches
![Page 25: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/25.jpg)
Condition Documentation ‐ Sketches
![Page 26: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/26.jpg)
Condition Documentation ‐ Sketches
![Page 27: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/27.jpg)
Condition Documentation ‐ Sketches
![Page 28: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/28.jpg)
Condition Documentation ‐ Sketches
![Page 29: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/29.jpg)
IA‐3 Resurfacing ‐
Pocahontas County, Iowa
Basilica‐style cathedral,
constructed in 1901
Stone masonry
foundation
Multi‐wythe exterior
walls/pilasters
Condition Documentation ‐ Sketches
![Page 30: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/30.jpg)
IA‐3 Resurfacing ‐
Pocahontas County, Iowa
Basilica‐style cathedral,
constructed in 1901
Stone masonry
foundation
Multi‐wythe exterior
walls/pilasters
Condition Documentation ‐ Sketches
![Page 31: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/31.jpg)
IA‐3 Resurfacing ‐
Pocahontas County, Iowa
Basilica‐style cathedral,
constructed in 1901
Stone masonry
foundation
Multi‐wythe exterior
walls/pilasters
Wood‐framed primary
floor
Plaster interior finishes
Condition Documentation ‐ Sketches
![Page 32: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/32.jpg)
IA‐3 Resurfacing ‐
Pocahontas County, Iowa
Basilica‐style cathedral,
constructed in 1901
Stone masonry
foundation
Multi‐wythe exterior
walls/pilasters
Wood‐framed primary
floor
Plaster interior finishes
Masonry bell tower
Condition Documentation ‐ Sketches
![Page 33: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/33.jpg)
IA‐3 Resurfacing ‐
Pocahontas County, Iowa
Interior plan view
sketches
Condition Documentation ‐ Sketches
![Page 34: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/34.jpg)
IA‐3 Resurfacing ‐
Pocahontas County, Iowa
Interior plan view
sketches
Condition Documentation
![Page 35: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/35.jpg)
IA‐3 Resurfacing ‐
Pocahontas County, Iowa
Interior plan view
sketches
Exterior elevation view
sketches
Condition Documentation
![Page 36: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/36.jpg)
IA‐3 Resurfacing ‐
Pocahontas County, Iowa
Interior plan view
sketches
Exterior elevation view
sketches
Survey Photographs
Condition Documentation
![Page 37: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/37.jpg)
IA‐3 Resurfacing ‐
Pocahontas County, Iowa
Interior plan view
sketches
Exterior elevation view
sketches
Survey Photographs
Drone Video Inspection
Condition Documentation
DRONE VIDEO
![Page 38: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/38.jpg)
Detailed Vibration Analysis
![Page 39: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/39.jpg)
Sensitive Structures Structures of historic significance Structures with sensitive finishes Structures with sensitive instruments
–Hospitals–Research Facilities–Manufacturing
Large number of affected buildings Dense Residential/Commercial Areas
Need for Detailed Analysis
![Page 40: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/40.jpg)
People Primary perceptible/disturbing Secondary effects
Structures Structural Damage Architectural Damage (Finishes)
Equipment Vibration‐sensitive research, advanced technology
Vibration Receivers
![Page 41: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/41.jpg)
Survey Existing Background Vibrations Analyze Anticipated Vibration Levels
Analyze vibration propagation characteristics Assess specific construction methods Analyze response of subject building
Assess impact of vibrations Assess proposed construction methods Develop mitigation measures
Detailed Analysis Procedures
![Page 42: Iowa DOT Seminar Preconstruction 2B · Pre‐construction condition survey Document all aspects of the structural condition through observations, actual measurements, plan sketches,](https://reader033.fdocuments.us/reader033/viewer/2022050103/5f4238965764180d8b3891a3/html5/thumbnails/42.jpg)
Questions?