IOF Nanosense
-
Upload
ronald-thoelen -
Category
Documents
-
view
40 -
download
2
Transcript of IOF Nanosense
![Page 1: IOF Nanosense](https://reader030.fdocuments.us/reader030/viewer/2022032700/55d59ff2bb61ebff158b458b/html5/thumbnails/1.jpg)
NanosenseProf. dr. ir. Ronald Thoelen
02/12/2014
![Page 2: IOF Nanosense](https://reader030.fdocuments.us/reader030/viewer/2022032700/55d59ff2bb61ebff158b458b/html5/thumbnails/2.jpg)
The project ‘Nanosense’
NANO - SENSOR
READ-OUT TECHNIQUERECEPTOR
![Page 3: IOF Nanosense](https://reader030.fdocuments.us/reader030/viewer/2022032700/55d59ff2bb61ebff158b458b/html5/thumbnails/3.jpg)
Heat Transfer Resistance (HTM)
![Page 4: IOF Nanosense](https://reader030.fdocuments.us/reader030/viewer/2022032700/55d59ff2bb61ebff158b458b/html5/thumbnails/4.jpg)
MIP
Target-molecule
monomer
MAA
cross-linker
EGDM
CHCl3porogene
initiator
AIBN
+
+
Synthetic receptors (MIPs)
![Page 5: IOF Nanosense](https://reader030.fdocuments.us/reader030/viewer/2022032700/55d59ff2bb61ebff158b458b/html5/thumbnails/5.jpg)
Nanosense
1. Heat-Transfer Resistance Based Analysis of Bioparticles (US2014011198)▪ Applicants: IMEC and UHasselt
▪ Status: granted in EP, close to granting in US
▪ Scope: biosensing device for detection and/or characterization of target DNA and/or RNA bioparticles
▪ Current application not covered by this patent
2. Heat-Transfer Resistance Based Analysis of Bioparticles (US2014242605) ▪ Applicants: IMEC and UHasselt
▪ Status: EP-search report available, office action March 2015
▪ Scope: biosensing device for detection and/or characterization of target bioparticles, a.o. cells or small molecules
▪ Current application covered by this patent application
IP
![Page 6: IOF Nanosense](https://reader030.fdocuments.us/reader030/viewer/2022032700/55d59ff2bb61ebff158b458b/html5/thumbnails/6.jpg)
Literature @ UHasselt
![Page 7: IOF Nanosense](https://reader030.fdocuments.us/reader030/viewer/2022032700/55d59ff2bb61ebff158b458b/html5/thumbnails/7.jpg)
Proof-of-concept
The technique has been proven for:
TARGETs: nicotine, serotonin, histamine, caffeïne, malachite green, biogenic amines, …
ANALYTEs: buffer solutions, water, saliva, urine, blood plasma, wholeblood, …
Dose-response curve of
nicotine in PBS
=> LOD ~ 30 nM
HTM-determination
of serotonin in non-diluted blood plasma
Marloes Peeters et al., Analytical and Bioanalytical Chemistry 405, 6479 – 6487 (2013)
Bram Geerets et al., Sensors 13, 9148 – 9159 (2013).
![Page 8: IOF Nanosense](https://reader030.fdocuments.us/reader030/viewer/2022032700/55d59ff2bb61ebff158b458b/html5/thumbnails/8.jpg)
State-of-the-art
- Use of bulk-MIPs
- Stamping technique / spraycaoting
- Flow-cell and drop-cell
- Home-made setup
![Page 9: IOF Nanosense](https://reader030.fdocuments.us/reader030/viewer/2022032700/55d59ff2bb61ebff158b458b/html5/thumbnails/9.jpg)
Valorisation
• What are the most interesting TARGETs? (market potential, emerging technologies, FTO, etc.)
• Detection limits and dynamic range?
• Complexity of the analytes (preparation necessary?)
• Single testing or multi-parameter testing?
ENVIRONMENTAL FOOD SAFETY HEALTH