I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII...

43
PUBLIC Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 1 I/O Update 2018 Flex 5000 Compact 5000

Transcript of I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII...

Page 1: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC

Copyright © 2016 Rockwell Automation, Inc. All Rights Reserved. 1

I/O Update 2018

• Flex 5000

• Compact 5000

Page 2: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 2

FLEX 5000™ I/OShipping in 2018!

Performance

1 Gb EtherNet/IP™

1 Gb Backplane Speed

Easy snap-on installation

Removal and Insertion Under Power

(RIUP)

Network Media and Topology

2 Copper/2 Fiber Ports

Supports DLR, Star, Linear, PRP

Standard I/O

32 Channel Digital In/Out

8 Channel Analog In/Out

Consistent I/O Wiring

Direct Termination of 2, 3 & 4

wire devices

Safety I/O (SIL 3, PLe, Cat. 4)

16 Channel Digital In/Out

4 Channel Analog In/OutRugged Design

Operating

Temperature:

-40 °C…70 °C

Extreme

Environments:

Class G1, G2, and G3

Hazardous

Environments:

Class I, Div. 2

Zone 2 Groups

A, B, C, D, E, F

Page 3: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 3

FLEX 5000™ I/OFlexibility in Design and Maintenance

Simplified System Design and Maintenance

Mount up to 8 or 16

I/O Modules

Dual Color Light-emitting

Diodes (LEDs) for Status &

Diagnostics

Interconnect Cable

Bank Expansion

Adapter Power

Removal Terminal

Stair Step Design for

Ease of Wiring / Visibility

Consistent Power

Wiring with Jumpers

Maximum I/O

Follows Module

Density

Page 4: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 4

FLEX 5000™ I/OFlexibility in Design and Maintenance

Simplified System Design and Maintenance

Z-Axis RemovalRemovable

Terminal Block

On-Line Addition*

& RIUP

Easy Terminal

Base Selection

Simple Plug-in

Shielding TB

Current Sourcing -

Analog

One to One TB

Mapping

TB3, TB3I, TB3W,

TB3T, TB3AC, TB32

Per Channel CJC,

Remote CJC

support

Screw and

Spring/Push-in TB

Options

On-line Addition for Standard modules only

Page 5: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 5

FLEX 5000™ I/OFlexible Mounting Options

Mount the I/O to Meet Application Requirements

Certifications available at release

Horizontal or Vertical

XT for G3

-40 °C…70 °C Standard

-1000…2000 m Altitude

Page 6: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 6

FLEX 5000™ I/OComparison to FLEX™ I/O

Same DIN Rail

Footprint as FLEX I/O

Maximum Wiring

Consistency

Increased Capacity &

System Performance

FLE

X 5000™

I/OF

LEX

™ I/O

FLEX 5000™ I/O FLEX 5000™ I/OFLEX 5000™ I/O

Page 7: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 7

FLEX 5000™ I/OEverything is in the Channel

Control and Configure at the Channel Level

Configuration

Standard Data Structures

Per Channel selection

Scaling & Alarming on

Module

Protection &

Diagnostics

Electronic Fusing,

Overvoltage, Overload,

Reverse Polarity

Power, Temperature,

Open Wire, Short Circuit

Time Stamping

with PTP

I/O COS

Diagnostics

Events

Page 8: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 8

FLEX 5000™ I/OIntegrate Safety up to SIL 3

Designed for

Fail-safe Applications

CIP™ Safety Modules

Single channel

SIL 3 /PLe/Cat. 4

Integrated Control and Safety for the Process Industry

Simplify Safety

Implementation

Mix Standard and

Safety I/O on same I/O

bank

Full Range of

Modules

Digital, Analog, HART,

Temperature and

Frequency

*Available in Future Release

Page 9: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 9

FLEX 5000™ I/OFlexible Network Topologies

DLR | Star | Linear | PRP*

Copper or SFP Fiber

Ports*Scheduled for December 2018

Page 10: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 10

Digital I/O

≤ 100 µs screw to backplane

200us RPI Support

Counter Functionality

Input Events

Scheduled Output

≤ 1 ms S2S Response Time*

Analog I/O

≤ 2 ms screw to backplane

200us RPI Support

16 bits Resolution

Alarms and Scaling

Current Sourcing

≤ 5 ms S2S Response Time*

Universal Analog Input

FLEX 5000™ I/OHigher Performance – Standard I/O

*Under test conditions

Page 11: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 11

Safety Digital I/O

~4 ms Safety Reaction Time

2 ms RPI Support

Single Channel SIL 3/PLe/Cat. 4

Support Low, High, Continuous

Demand

Safety Analog I/O

~10 ms Safety Reaction Time

2 ms RPI Support

16 bits Resolution

Single Channel SIL 3/PLe/Cat. 4

Channel-to-Channel Isolation

HART V7 Support

Configurable Safety State

FLEX 5000™ I/OWide Range and Flexible – Safety I/O*

*Available in Future Release

Page 12: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 12

Smart.Automation system with

intelligence that just works.

Productive.Simple integrated development resulting in improved

real-time operations and expedited maintenance.

Secure.Respond to your process

faster with intelligent control.

Improve real-time operations with

enhanced device integration.Safeguard your assets

and protect your brand.

FLEX 5000™ I/ODesigned for The Connected Enterprise

Diagnostics

Premier HART Integration

Enhanced Asset Data

On-Line Maintenance

Device Health

System Topology

Birth Certificates

Secure Boot

Implicit Protection

Page 13: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 13

FLEX 5000™ I/ORelease Schedule

Standard

Catalog Description

5094-AENTR EtherNet/IP Adapter RJ45 8 I/O

5094-AEN2TR EtherNet/IP Adapter RJ45 16 I/O

5094-IB16 16 Point Digital Input

5094-OB16 16 Point Digital Output

5094-OW8I 8 Channel Relay Output Isolated

5094-IF8 8 Channel Analog Input

5094-IY8 8 Channel Universal Analog Input

5094-OF8 8 Channel Analog Output

5094-HSC 2 Channel High-Speed Counter

SIL 3 Safety

Catalog Description

5094-IB16S 16 Point Digital Input Safety

5094-OB16S 16 Point Digital Output Safety

5094-OW4IS 4 Channel Relay Output Isolated Safety

5094-IF4IHS4 Channel Analog Input Isolated HART

Safety

5094-OF4IHS4 Channel Analog Output Isolated HART

Safety

5094-IRT8S 8 Channel RTD/Thermocouple Safety

5094-IJ2IS 2 Channel Isolated Frequency Safety

All catalogs are available in Extreme Environment (XT) variant for G3 compliance

Standard

Catalog Description

5094-AENSFPRXT EtherNet/IP Adapter SFP w XT

5094-AEN2SFPRXT EtherNet/IP Adapter SFP w XT

5094-IB32 32 Point Digital Input

5094-OB32 32 Point Digital Output

5094-OB82A 8 Point Digital Output 2 Amp

5094-IA16 16 Channel AC Input

5094-OA16 16 Channel AC Output

5094-IF8IH8 Channel Analog Input

Isolated HART

5094-OF8IH8 Channel Analog Output

Isolated HART

5094-IJ2I 2 Channel Isolated Frequency

Future ReleaseCY18

Specific dates to be advised

Page 14: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 14

FLEX 5000™ I/OWhen to Consider FLEX 5000 I/O Versus FLEX I/O

Continue to attach FLEX™ I/O with ControlLogix® 5570 Architecture

FLEX I/O is ACTIVE and supports all generations of Logix5000™ controllers

Longevity letters are available, including description of lifecycle support

Attach FLEX 5000™ I/O with CompactLogix™ 5380/ControlLogix 5580 Standard or

Safety Architecture

Page 15: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 15

Flexible Network Media

and Topologies

Rugged I/O Designed for

Process Control

Wide Range of Standard

and Safety Modules

Page 16: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 16

Compact 5000TM I/O Modules

High performance

• Dual 1-Gb Embedded EtherNet/IP Ports

Power• Separate system power for better isolation

• Built-in power input with field power to I/O modules

Enhanced standard functions• Common data structures

• Change of State

• Immediate output

• Timestamping – 10 ms accuracy at 1 ns resolution

• Native simple counters

Local and distributed I/O for CompactLogix™ 5380Distributed I/O for ControlLogix® 5580

New in CY2017:• 120/240VAC Input and Output modules

• Additional density options for relay output (16-channel) and 24 VDC

output (8-channel)

• Small network adapter

New in Q1/Q2 CY2018:• Serial module

• Digital Safety I/O

Page 17: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 17

5069-AENTR Overview

56mm 22mm 22mm 22mm 22mm 36mm

5069-AENTR AC In Digital

Out

AC Out Serial Relay Out

AENTR vs. AEN2TR - Comparison

• Slimmer Design

• No USB Port

• No SD Card for Module Configuration

• No Diagnostic Display Screen

Page 18: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 18

Serial module : Release 1 features

5069-SERIAL : Generic ASCII/Modbus RTU & ASCII

Generic ASCII using tag base programming

Modbus Master communication

Up to 50 commands per port

Data mapped directly back to module tags

Reduce need to create complex programming

Modbus Slave communication

Up to 30 data per port

Quick configuration at AOP.

*Performance and features are preliminary, changes may happen

Page 19: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 19

Chassis & Distributed I/ORockwell Automation® Platform Positioning

ControlLogix®

Chassis-based I/O

• I/O diagnostics for

detection of both

system and field-

side failures

• Electronic keying to

help prevent

replacement errors

• Wide range of

modules from high

performance to

process control

ArmorBlock®

On-Machine™ I/O

• IP67 rated

modules

• Reduces wiring

and panel space

• Quick connect for

daisy chaining

modules

• Analog, Digital,

specialty, machine

safety and IO-Link

options available

1719 Ex,

1715 RedundantIntrinsic Safety and High

Availability I/O

• 1719 Ex I/O for

hazardous area

locations

• 1715 Redundant I/O

provides

high availability for

ControlLogix

controllers

Compact I/O™,

Compact 5000™

Discrete Machine I/O

• High-performance

Compact 5000™ I/O for

CompactLogix™ 5380

and ControlLogix 5580

• High-density Compact

I/O™ for

CompactLogix™ 5370

POINT I/O™

Smart Machine

Distributed I/O

• Low-cost platform

with lower density

inputs and outputs

• Compact design

makes installation

easier

• Machine safety,

specialty and IO-

Link options

available

Dynamix™

Condition Monitoring

• Integrates machine

protection with your

standard

control system

• Dual Ethernet ports

supporting both

Linear and Device

Level

Ring topologies

FLEX™,

FLEX 5000™

Process Distributed I/O• High-performance

FLEX 5000TM I/O for

CompactLogix™ 5380

and ControlLogix®

5580

• High-channel density

on a distributed

platform

Page 20: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC

Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 20

HMS Linking Devices

Page 21: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 21

HMS Anybus DLR Linking Devices

DLR to Profibus - HMS-EN2PB-R

DLR to Modbus - HMS-EN2MB-R

DLR to Serial - HMS-EN2SE-R

All have integration with Studio 5000 Logix Designer through custom AOPs

Offloads PLC from having to perform additional calculations for protocol

converter modules

More cost efficient than an in-chassis solution

Page 22: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 22

HMS Anybus DLR Linking Devices

Page 23: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC

Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 23

PanelView™ 5000 Family of Operator InterfacesFeaturing Studio 5000 View Designer® Software

Page 24: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 24

PanelView 5000 Major Releases through 2018*

Releases to Date

PanelView 5500 withView Designer

PanelView™ 5310 withv4 View Designer

July 2018

PanelView™ 5510

Dec 2018

v5 View Studio Designer

• All new EOI Platform

• For new applications

leveraging 5370 / 5480 /

5570 / 5580 controllers

• Advanced Development

Environment

• Enhanced levels of

productivity

• Addition to PanelView™

5000 family

• Targeted at mid-size and

smaller applications not

requiring a haz loc rating

• For new applications

leveraging 5370 / 5480 /

5570 / 5580 controllers

• New v4 features

• Replaces PanelView 5500

• Next Gen Hardware

featuring a dual core

processor

• Runs v4 and v5 + future

generation software

• For new applications

leveraging 5370 / 5480 /

5570 / 5580 controllers

• PanelView 5310 and

PanelView 5510 compatible

• Provides multi-controller

support for PanelView 5510

• Increased screen and alarm

count

• Logix tag-based alarms

• Recipe Management

* Future dates are tentative.

Page 25: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 25

MODERN DESIGN

For mid-size and smaller applications

6”*, 7”W, 9”W, 12”W

1.46 GHz Processor, 1 Gb RAM, 4 Gb Flash

Runs v4 and newer View Studio software

Touch screen only with aluminum bezel

Single port Ethernet

DC power

Not C1D1* 6” unit to be AFC mid 2018

Page 26: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 26

Specifications PanelView 5310 PanelView 5500* PanelView 5510*

Multi-Version Support(Ability to install and run multiple versions of

configuration software side by side)

Yes YesYes

Application Limits1 controller, 50 screens, 1000

alarms

1 controller, 100 screens, 1000

alarms

1 controller, 100 screens, 1000

alarms

Resize Application on

DownloadYes Yes

Yes

ControlLogix® Controller

CompatibilityControlLogix® 5570 (v27+) / 5580 (v29+)

CompactLogix™ Controller

CompatibilityCompactLogix™ 5370 (v27+) / 5380 (v29+) / 5480 (v31+)

PanelView 5000 Family Comparison

* Note: PanelView 5500 will receive a hardware upgrade and will be renamed PanelView 5510

Page 27: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

Project Explorer contains the structure

of the project

Properties Pane helps configure

elements

Searchable Toolbox of pre-built elements

Canvas area used for creating screens

VIEW DESIGNERGraphic Explorer displays graphic

elements

Page 28: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

10”

19”

+1000MORE

SCALABLE GRAPHICS

Page 29: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

29

Comprehensive library of graphics in Studio 5000 View Designer®: shapes, common controls, equipment, ISO

and ISA symbols

Embedded animation and behavior: color and movement animation and control actions built into many objects

SVGs allow reusable screen content - automatically scale screen content as appropriate for the target terminal

Graphical objects are linked to controller objects

Typ

ical

HM

IP

anel

Vie

w

5500

ENHANCED GRAPHICS

Page 30: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

DATA LOGGING Log data on the PanelView 5000 terminal and display that historical data on a trend

Up to 250 tags can be logged

Logs are stored in circular logs

Logs are stored on an SD card in the PanelView 5000

Logs can be exported in csv format to a USB flash drive using a

predefined Settings screen

Page 31: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

HISTORICAL TRENDING No trend configuration is required to display logged data

If a trend trace is bound to a tag that is also logged, the trend will

automatically show historical data (if the trend is panned to a time where

no real-time data exists for that tag)

Trends show historical data immediately when the screen is displayed

Page 32: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

EMULATOR CAPABILITY Emulator lets you test run a project without downloading to a physical

PanelView™ 5000 terminal

Page 33: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

VNC SUPPORT The PanelView 5000 terminals use a built-in VNC server to

support a remote VNC client for monitoring and

troubleshooting

Passwords can be configured to allow full read/write access

or read-only access to only VNC client users who enter the

correct password

A new settings screen can be used at runtime to lock down

the PanelView 5000 to disallow VNC access or limit it to

read-only access if desired

A new system tag indicates if a VNC client is connected

Page 34: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

LOAD FROM REMOVABLE MEDIA You can save a View Designer project as a runtime image .vpdr file

The runtime image file can be copied to a USB flash drive or an SD

card that can then be inserted into the PanelView 5000 terminal

A new settings screen on the PanelView 5000 can be used to select

the desired runtime image file and initiate a download to the terminal

Optionally, you can choose to use the “HMI to controller” path

configured as part of the runtime image file. Or, continue to use the

path configured in the existing project currently running on the

PanelView 5000

Makes it easier to send an updated project to a location where

you do not know the exact controller path

Page 35: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 35

LANGUAGE SWITCHING Use a language switch command to switch to any of the languages in the project

The language switch will also switch the language strings from the Logix controller including

extended tag properties and alarm messages

Page 36: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 36

HMI Button Control

HMIBC HMIButtonJog …

HMIBC

HMI Button Control

HMIBC HMIButtonJog …

HMIBC

HIGH-SPEED BUTTON CONTROL

Eliminate hardwired push buttons

Save the expense of the push buttons, wiring, I/O and labor

Page 37: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC

Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 37

Product Selection Toolbox (PST)

Page 38: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 38

Product Selection Applications/Capabilities

Selection/configuration assistance,

estimating, quoting, quote generation Design/validate IA systems, subsystems, networks

Product Selection and ConfigurationSystem Layout, Analyzing, & Sizing

Complete Rockwell Product Catalog and Configurators

IAB Mobile

MigrationsApp

Simplified mobile

version of IABMigrate from SLC to

CompactLogix/ControlLogix

Product Catalog App

RAISEConfigurator

Product configurator forRockwell & Encompass Products

Find replacements for non-RA/RA

Products

Configure modular control

system starters/load feeders on busbars

Automation BuilderSafety

(Could transition to our team

from Portfolio Marketing later in year)

Page 39: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 39

IAB download @http://raiseinstall.rockwellautomation.com/pst-lite.html

Page 40: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 40

IAB DVDs for install available from local Distributor

Page 41: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 41

Released in November, 2017:

iPhone iOS 8 through iOS 11

Android phones and tablets versions 4.2 & above

Available since 2013:

iPad with iOS 8 through iOS 11

41

Released

Catalog App

Page 42: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

PUBLIC Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 42

Migrations App

Quickly migrate:

• SLC™ 500 to a ControlLogix® or a CompactLogix™ controller-based configuration

• PLC-5® to a ControlLogix® controller-based configuration

1. Specify current configuration by placing modules into chassis

2. App selects equivalent ControlLogix or CompactLogix hardware

3. App provides migration details & BOM in CSV and share via email

Released

Page 43: I/O Update 2018 · 2018-05-02 · 5069-SERIAL : Generic ASCII/Modbus RTU & ASCII Generic ASCII using tag base programming Modbus Master communication Up to 50 commands per port Data

www.rockwellautomation.com

PUBLIC

Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. 43

Thank You!