Pozidrive PZ2 4.5mm All product(s) must be installed by a suitably competent electrician giving consideration to their intended use and in accordance with the current edition of BS 7671 (IET Wiring Regulations). The Electricity at Work regulations and the Health and Safety at Work Act shall be complied with. Only equipment and arrangements specified in Hager’s technical documentation / catalogue shall be used Install in the vertical plane only. Notice: To prevent potential overheating from loose connections the installer shall check connections are tightened to the torque levels stated in these instructions prior to energising this board. This check should include factory made connections which may have loosened in transit. JKD1***PM Notice d’instructions User instructions Bedienungsanleitung Instrucciones de uso Instruções Bruksanvisning Gebruiksaanwijzing Pozidrive PZ2 2.5 Designation H W D JKD146PM 1100 465 165.5 JKD166PM 1100 465 165.5 JKD164PM 1100 465 165.5 JKD168PM 1250 465 165.5 JKD188PM 1250 465 165.5 JKD186PM 1250 465 165.5 JKD1416PM 1400 465 165.5 JKD1164PM 1400 465 165.5 JKD1812PM 1400 465 165.5 JKD1128PM 1400 465 165.5 JKD11212PM 1400 465 165.5 Fixing Centres A B C D JKD146PM 365 100 900 450 JKD166PM 365 100 900 450 JKD164PM 365 100 900 450 JKD168PM 365 100 1050 525 JKD188PM 365 100 1050 525 JKD186PM 365 100 1050 525 JKD1416PM 365 100 1200 600 JKD1164PM 365 100 1200 600 JKD1812PM 365 100 1200 600 JKD1128PM 365 100 1200 600 JKD11212PM 365 100 1200 600 Warranty This distribution board is offered with a 24 month warranty against defective material or manufacture. If a warranty claim is necessary, please call the technical support number given at the bottom of the page and we will be pleased to help. Interface Characteristics Rated & operational voltage (U n / U e ) 415V a.c. 50Hz Rated insulation voltage (U i ) 690V a.c. 50Hz Rated impulse withstand voltage (U imp ) 4kV Rated current of the Assembly (I nA ) JKD1xxPM 125A Rated current of an Outgoing circuit (I nC ) MCB 0.5A - 63A (marked rated current on device) RCBO 6A - 50A (marked rated current on device) Rated Current of Pan Assembly Upper Pan I n = 125A (RDF = 1) Lower Pan I n = 125A (RDF = 1) Rated conditional short-circuit current of the ASSEMBLY (I cc ) 10kA 1 with equipment and arrangements specified in Hager’s technical documentation / catalogue. MCB/RCBO 10kA rating applied as BS EN 61439-3 is intended for use by ordinary persons. 1 Current limitation characteristics specified in Hager’s technical documentation / catalogue Protection against electric shock DBO shall be installed in an electrical system conforming to IEC 60364 / BS 7671 Rated diversity factor (RDF) / Values of assumed loading 10 way - 24 way = 0.5 Note: RDF only applies to continuously and simultaneously loaded circuits. Rated frequency (fn) 50 Hz Pollution degree 2 Types of system earthing for which the ASSEMBLY is designed TNC-S, TN-S and TT when installed in an electrical system conforming to BS 7671 Intended locations Indoor use only Stationary ASSEMBLY Degree of protection IP3XD with Door Closed IP2XC with Door Open and compliment of outgoing devices and or blanks fitted. Intended use Distribution boards intended to be operated by ordinary persons (DBO) Electromagnetic compatibility (EMC) classification EMC Environment B External design Wall-mounted, surface type, enclosed assembly. Mechanical impact protection IK05 The type of construction Fixed parts DBO Type Type B DBO Accessories JK01B Single Pole Blank JK222PK JK1 / JK2 Door Lock Kit JK1PLATEM Gland Plate + Drill Markings JK107DL 7 Input Data Logger with TCP/IP Hager Technical Help Line: 01952 675 689 Hager Technical Fax: 01952 675 557 Website: www.hager.co.uk E-mail us: [email protected] Twitter: @hageruk GB ZD0787 Issue 2 ZD0787 Issue 2 1 4 ZD0787 Issue 2 ZD0787 Issue 2 Invicta 3

Transcript of Invicta 3 - ews.uk.com · PDF filePozidrive PZ2 4.5mm All product(s) must be installed by a...

Pozidrive PZ2 4.5mm

All product(s) must be installed by a suitably competent electrician giving consideration to their intended use and in accordance with the current edition of BS 7671 (IET Wiring Regulations).

The Electricity at Work regulations and the Health and Safety at Work Act shall be complied with.

Only equipment and arrangements specified in Hager’s technical documentation / catalogue shall be used

Install in the vertical plane only.

Notice:To prevent potential overheating from loose connections the installer shall check connections are tightened to the torque levels stated in these instructions prior to energising this board. This check should include factory made connections which may have loosened in transit.

JKD1***PM Notice d’instructionsUser instructionsBedienungsanleitungInstrucciones de usoInstruçõesBruksanvisningGebruiksaanwijzing

Pozidrive PZ2

2.5

Designation H W DJKD146PM 1100 465 165.5

JKD166PM 1100 465 165.5

JKD164PM 1100 465 165.5

JKD168PM 1250 465 165.5

JKD188PM 1250 465 165.5

JKD186PM 1250 465 165.5

JKD1416PM 1400 465 165.5

JKD1164PM 1400 465 165.5

JKD1812PM 1400 465 165.5

JKD1128PM 1400 465 165.5

JKD11212PM 1400 465 165.5

Fixing Centres A B C DJKD146PM 365 100 900 450

JKD166PM 365 100 900 450

JKD164PM 365 100 900 450

JKD168PM 365 100 1050 525

JKD188PM 365 100 1050 525

JKD186PM 365 100 1050 525

JKD1416PM 365 100 1200 600

JKD1164PM 365 100 1200 600

JKD1812PM 365 100 1200 600

JKD1128PM 365 100 1200 600

JKD11212PM 365 100 1200 600

WarrantyThis distribution board is offered with a 24 month warranty against defective material or manufacture. If a warranty claim is necessary, please call the technical support number given at the bottom of the page and we will be pleased to help.

Interface CharacteristicsRated & operational voltage (Un / Ue)415V a.c. 50Hz

Rated insulation voltage (Ui)690V a.c. 50Hz

Rated impulse withstand voltage (Uimp)4kV

Rated current of the Assembly (InA)JKD1xxPM 125A

Rated current of an Outgoing circuit (InC)MCB 0.5A - 63A (marked rated current on device)RCBO 6A - 50A (marked rated current on device)

Rated Current of Pan AssemblyUpper Pan In = 125A (RDF = 1)Lower Pan In = 125A (RDF = 1)

Rated conditional short-circuit current of the ASSEMBLY (Icc) 10kA1 with equipment and arrangements specified in Hager’s technical documentation / catalogue.

MCB/RCBO 10kA rating applied as BS EN 61439-3 is intended for use by ordinary persons.

1Current limitation characteristics specified in Hager’s technical documentation / catalogue

Protection against electric shockDBO shall be installed in an electrical system conforming to IEC 60364 / BS 7671

Rated diversity factor (RDF) / Values of assumed loading10 way - 24 way = 0.5

Note: RDF only applies to continuously and simultaneously loaded circuits.

Rated frequency (fn)50 Hz

Pollution degree2

Types of system earthing for which the ASSEMBLY is designedTNC-S, TN-S and TT when installed in an electrical system conforming to BS 7671

Intended locationsIndoor use only

Stationary ASSEMBLY

Degree of protectionIP3XD with Door ClosedIP2XC with Door Open and compliment of outgoing devices and or blanks fitted.

Intended useDistribution boards intended to be operated by ordinary persons (DBO)

Electromagnetic compatibility (EMC) classificationEMC Environment B

External design Wall-mounted, surface type, enclosed assembly.

Mechanical impact protectionIK05

The type of constructionFixed parts

DBO TypeType B DBO

AccessoriesJK01B Single Pole Blank

JK222PK JK1 / JK2 Door Lock Kit

JK1PLATEM Gland Plate + Drill Markings

JK107DL 7 Input Data Logger with TCP/IP

Hager Technical Help Line: 01952 675 689Hager Technical Fax: 01952 675 557

Website: www.hager.co.ukE-mail us: [email protected]: @hageruk

GB

ZD0787 Issue 2ZD0787 Issue 2 14

ZD

0787

Issu

e 2

ZD

0787

Issu

e 2

Invicta 3

T = Min. 2.8NmMax. 3.5Nm

L1

L2

L3

L1

L2

1

2

3

7

8

9

ISOLATE SUPPLYBEFORE REMOVING COVER

L1

L2

L3

L1

L2

1

2

3

7

8

9

ISOLATE SUPPLYBEFORE REMOVING COVER

LightingSupply

SocketsFirst Floor

L1

L2

L3

1

2

3

7

8

9

L1

L2

L3

4

5

6

10

11

12

Pozidrive PZ2

Pozidrive PZ2

Points with central ‘easy fit’ fixing point

Drill centre mark provided when fitting SWA or conduit

Use product carton / packaging to reduce the swarf when removing end plate section

Removal of gland plate

Pozidrive PZ24.5mm

Pozidrive PZ2 4.5mm

Cut tabs and remove insert when using gland larger than 32mm

Cable protection built into end plate for trunking entry

Protected cable whilst drawing into board without need for SRBP / Paxolin laminated sheet

Pozidrive PZ2

Fitting MCB / RCBO

Ability to number outgoing ways on busbar stack

Ability to write on with pencil when installing.

Dedicated label pack for front cover way labelling

When fitting to trunking, use the endplate cut-out lines as a template for the hole in the trunking

Pozid

rive PZ

24.5m

m

Pozidrive PZ2 4.5mm

32 ZD0787 Issue 2ZD0787 Issue 2