Invertor SIPF150
-
Upload
fallenangel006 -
Category
Documents
-
view
214 -
download
0
Transcript of Invertor SIPF150
-
8/13/2019 Invertor SIPF150
1/3
-
8/13/2019 Invertor SIPF150
2/3
SIPF150Mod e l
Lum inance Va r iance
I t e m C o n d it io n A p p lie d Vo lt a g e O u t p u t C u r r e n t
Lum inance @Max. Btw n. p in 5 & p in 6 0.0 Vdc 6.0 m A
Lum inance @Min. Btw n. p in 5 & p in 6 4.5 Vdc 2.5 m A
2.7
MIN.
(2)
2CD.3
7
5
+ 0.10.05
0.051 0.15
1 0.05
0.7+ 0.1
0.05
INPUT
22.7
0.3
(11.5
)
1PIN
+1.0(14.0) 67.50.3 (15.0)
2 3.52 7.5
1PIN
(1.2)
OUTPUT
7.3MAX
1.0
TYP
(4.0
)
(4.0
)
(8.
2) 1
4.7
0.3
96.50.5
No component and no patternon both sides
Lot Symbol
0
Cop yright 1999 Taiyo Yuden (USA), Inc. Sp ec ificat ions sub jec t t o c hang e w itho ut no tice.
T A I Y O Y U D E N ( U S A ) , IN C .1770 LaC osta Mead ow s Drive
San Marcos, CA 9206 9
(760) 471-40 01 / Fax: (760) 471-4 021
(8 0 0 ) 4 9 3 - 6 8 3 5
www.xentek.com [email protected]
-
8/13/2019 Invertor SIPF150
3/3
SIPF150Mod e l
Tec h No tes
C o n n e c t io n D ia g ra m
INVERTER
1
2
3
V(in)
V(in)
GND
5
4
3
2
CFL Low
NC
NC
NC
1CFL High
4
5
6
GND
On/Off
Bright
CN1Molex 52207-0517
CN2J ST SM02(8.0)B-BHS-1
SW
DC4.57.0V
DC04.5V
CCFT
SIPF-150
O ut p ut C ur r e nt O p t im iza t io n M e th o d
M aximum output current can be adjusted by applying bias
voltage between brightness control pins as shown below.
BrightnessControl DC Bias
(04.5 Vdc) 3
Gnd
2 V(in)
1 V(in)
4 Gnd
5
On/Off
6 Br ig ht ne ss
D C B ia s O u t p u t
Vo lt a g e C u r r e n t
L u m in a n c e M a x . 0 Vdc 6.0 mA
L u m in a n c e M i n . 4.5 Vdc 2.5 mA
The on/off control is achieved by using the on/off pin on the input
side of SIPF150. T he circuit for the remote on/off circuitry
consists of an active low TT L switch. When the circuit is open,
the IC Vcc is cut off. When the circuit is closed, IC Vcc is activated.
A mechanical switch or a TTL/C M O S gate needs to be placed
between the remote on/off pin and ground creating a condition
where the circuit is closed to activate the inverter. Either one of
the following will be required for the inverter to operate:
O ne recommended use of logic switch for remote on/off is
shown in the diagram below. Electrical specification for on/off
terminal is Low 0 to 0.4V, -0.4 mA or higher when switch is
closed.
O n/ O f f C o nt r o l
V(in)
On/Off Pin
To IC Vcc
0V Inverter Off
5V Inverter On
V(in)
On/Off Pin
To IC Vcc
SW (External)
1. T ie on/off pin to ground.
2. Add mechanical switch between on/off pin and ground, close switch.
3. Add T TL /C M O S switch between on/off and ground. Circuit must be closed for
unit to operate (as shown above right).