Introduction to the 2018 International Existing Building Code in Southern Nevada

Transcript of Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in...

Page 1: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Introduction to the2018 International ExistingBuilding Code in Southern Nevada

Page 2: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Speaker Biographies - 2018 IEBC Group

Edward Kaminski, P.E.• Clark County Department of Building & Fire Prevention – Fire Protection Engineer

• 2018 & 2021 ICC National IEBC Committees

• 2018 Southern Nevada ICC Amendment Committee Member

• Registered Fire Protection Engineer (Multiple States)

Brian Woodward, P.E.• Fire Safety Engineers – Founder & President

• 2006 & 2008 ICC National IEBC Committee Member

• 2018 Southern Nevada ICC IEBC Committee Co-Chair

• Registered Fire Protection Engineer (Multiple States)

2

Page 3: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

DISCLAIMERS

The opinions expressed here are our own

and do not represent the International

Code Council, Clark County Nevada, SNICC

or SNBO.

The presentation covers non-structural

aspects of the 2018 IEBC only.

3

Page 4: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Why use the IEBC ?

• IBC Chapter 34 was deleted in the 2015 IBC

• All Southern Nevada jurisdictions have now adopted 2018 IEBC

• LV City has been using the 2012 IEBC since 2014.

• IEBC is the starting point for all existing buildings

4

Page 5: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

2018 Southern Nevada IEBC Amendments

101.6.1 Appendix A, B, C are adopted.

102.4.3 Where this code refers to other codes

not adopted by this jurisdiction, the applicable

code adopted by the jurisdiction shall govern.

103-117 Administration sections are deleted

301.6 Baby Changing Tables...Whenever

a new restroom is constructed for use by

the public, a baby changing table shall be

installed…..

Exception: A facility that has been issued

a permit or license which restricts the

admission of children on the basis of age

shall be exempt from this requirement.

5

Page 6: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Arrangement of IEBCChapters Subjects

1-2 Administrative Requirements & Definitions

3 Provisions for All Compliance Methods

4 Repairs

5 Prescriptive Compliance Method

6-12 Work Area Compliance Method

13 Performance Compliance Method

14 Relocated Buildings

15 Construction Safeguards

6

Page 7: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 3 - All Compliance Methods

301.2 - Repairs comply with Chapter 4

301.3 - Alterations, additions or change of occupancy

comply of all existing buildings shall comply with ONE

of the following methods.

• Prescriptive Compliance Method (Chapter 5)

• Work Area Compliance Method (Chapter 6-12)

• Performance Compliance Method (Chapter 13)

Exception: Subject to approval of the

code official, alterations complying with

the laws in existence at the time the

building or the affected portion of the

building was built shall be considered

in compliance with the provisions of

this code……

7

Page 8: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Code Analysis should show

• Original Code of Record

• Compliance Method

• Repair or Alteration Level

• Is there a Change of Occupancy?

• Are there Automatic Sprinklers Throughout?

8

Page 9: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 3 - All Compliance Methods301.4 Accessibility - Shall comply with 2009

ICC A117.1

305 Accessibility For Existing Buildings.

305.1 Scope. The provisions of Sections 305.1

through 305.9 apply to maintenance, change

of occupancy, additions, and alterations to

existing buildings including those identified as

historic buildings.

302 General Provisions

302.1 - Applicability - The provisions of Section 302 shall apply to all alterations, repairs, additions,relocations of structures and changes of occupancyregardless of compliance method.

302.4 Existing Materials. Materials already in use in a building in compliance with requirements or approvals in effect at the time of their erection or installation shall be permitted to remain in use unless determined by the building official to be unsafe.

9

Page 10: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 3 - All Compliance Methods302.5 New and replacement materials.

Except as otherwise required or permitted by this code, materials permitted by the applicable code for new construction shall be used.

Like materials shall be permitted for repairs and alterations, provided that unsafe conditions are not created.

Hazardous materials shall not be used where the code for new construction would not permit their use in buildings of similar occupancy, purpose and location.

302.6 Occupancy and use. Where determining

the appropriate application of the referenced

sections of this code, the occupancy and use of

a building shall be determined in accordance

with Chapter 3 of the IBC.

303 - Structural Design Loads - See code text

10

Page 11: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 4 - Repairs401.2 - Compliance. The work shall not make the building less complying than it was before the repair was undertaken.

402.1 Replacement Glazing...must meet current IBC requirements

403.1 Fire Protection. Repairs shall be done in a manner that maintain the level of fire protection provided.

404.1 Means of Egress. Repairs shall be done in a manner that maintains the level of protection provided for the means of egress.

405 Structural - see code text

11

Page 12: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 4 Repairs

406 Electrical. Existing electrical wiring and equipment undergoing repair shall be

allowed to be repaired or replaced with like material.

407 Mechanical. Existing mechanical systems undergoing repair shall not make

the building less complying than it was before the damage occurred.

408 Plumbing. Plumbing materials and supplies shall not be used for repairs that

are prohibited in the UPC.

12

Page 13: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 5 - Prescriptive Compliance Method502 - Additions - Additions to any building or structure shall comply with the requirements of the IBC for new construction.

Alterations to existing buildings or structure shall be made to ensure that the existing building or structure together with the addition are not less complying with the provisions of the IBC than the existing building or structure was prior to the addition.

An existing building together with it’s addition shall comply with the height and area provisions of Chapter 5 of the IBC.

502.2 - Disproportionate earthquake damage

502.3 Flood hazard areas

502.4 Existing structural elements carrying

gravity load.

13

Page 14: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 5 Prescriptive Compliance Method

503 Alterations. Except as provided by

302.4(existing materials) or 302.5 (new and

replacement materials), alterations to any

building or structure shall comply with the

requirements of IBC for new construction.

Alterations shall be such that the existing

building or structure is not less complying with

the IBC than the existing building or structure

was prior to the alteration.

Exceptions:

1. Existing stairways shall not be required to

comply with IBC Section 1011 where

existing space does not allow a reduction

in pitch or slope.

2. Handrails otherwise required to comply

with IBC Section 1011.11 shall not be

required to comply with IBC Section

1014.5

3. ….14

Page 15: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 5 - Prescriptive Compliance Method

Additions

● 503.2 - Flood hazard areas

● 503.3 - 503.13 - Structural stuff

● 503.14 Smoke alarms in Individual sleeping units in Group R & I-1

occupancies

● 503.15 Carbon monoxide alarms in sleeping units and dwelling units in I-1, I-

2, I-4 and R occupancies. Exception for exterior surface work and work

involving non fuel burning appliances.

● 503.16 Refuge Areas - See code text for specifics

15

Page 16: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 5 - Prescriptive Compliance Method

506 - Change of Occupancy

A change of occupancy shall not be made in any

building unless that building is made to comply with

the requirements of the IBC for the use or occupancy.

Changes of occupancy in a building or portion of a

building shall be such that the existing building is not

less complying with the provisions of this code than

the existing building or structure was prior to the

change.

Subject to the approval of the building official

changes of occupancy shall be permitted

without complying with all of the requirements

of this code for the new occupancy provided

that the new occupancy is less hazardous

based on life and fire risk than the existing

occupancy.

506.1.1 Change in character of use - (see code

text)

16

Page 17: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 6 - Work Area Method

Work Area - That portion or portions of a building consisting of all reconfigured

spaces as indicated on the construction documents.

Work area excludes other portions of the building where incidental work entailed

by the intended work must be performed and portions of the building where work

not initially intended by the owner is specifically required by the code.

17

Page 18: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 6 - Work Area Method

602.1 Level 1 alterations include the removal

and replacement or the covering of existing

materials, elements, quipment, or fixtures

using new materials, elements, equipment, or

fixtures that serve the same purpose.

602.2 - Level 1 Alterations shall comply with

the provisions of Chapter 7

603.1 Level 2 alterations include the

reconfiguration of space, the addition or

elimination of any door or window, the

reconfiguration or extension of any system, or

the installation of any additional equipment.

603.2 Level 2 alterations shall comply with the

provisions of Chapter 7 for Level 1 Alterations

as well as the provisions of Chapter 8

18

Page 19: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 6 Work Area Method

604.1 Level 3 alterations apply where the work

area exceeds 50 percent of the building area.

604.2. Level 3 alterations shall comply with

the provisions of Chapters 7 and 8 …..as well

as the provisions of Chapter 9

19

Page 20: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 6 Work Area Method

605 Change of Occupancy. Change of occupancy provisions apply where the activity is

classified as a change of occupancy as defined in Chapter 2.

Change of Occupancy. A change in the use of a building or portion of a building that results in

any of the following:

1. A change of occupancy classification2. A change from one group to another group within an occupancy classification.3. Any change in use within a group for which there is a change in application of

requirements of this code.

605.2 Application. Changes of occupancy shall comply with the provisions of Chapter 10.

20

Page 21: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 6 Work Area Method

606.1 Additions. Provisions for additions shall

apply where work is classified as an addition as

defined in Chapter 2

Addition. An extension or increase in floor

area, number of stores, or height of a building

or structure.

606.2 Additions to existing buildings shall

comply with the provisions of Chapter 11

607 Historic buildings

608 Relocated buildings.

21

Page 22: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 7 - Alterations Level 1

701.2 Conformance - An existing building or

portion thereof shall not be altered such that

the building becomes less safe than its existing

condition.

Exception: Where the current level of safety or

sanitation is proposed to be reduced, the

portion altered shall conform to the

requirements of the IBC.

702 - Building Elements and Materials

703 Fire Protection

704 Means of Egress

705 Reroofing

706 Structural

707 Energy Conservation

22

Page 23: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 8 - Alterations Level 2

801.1 Level 2 Alterations must comply with

Chapter 8

Exception: Buildings in which the

reconfiguration is exclusively the result of

compliance with accessibility requirement of

Section 305.7 shall be permitted to comply

with Chapter 7.

801.2 - All work shall comply with Chapter 7 in

addition to Chapter 8

801.3 New construction elements,

components, systems and spaces shall comply

with the requirements of the IBC.

Exceptions; - See Code text

23

Page 24: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 8 - Alterations Level 2

802 Building Elements and Materials

802.1 Vertical openings

802.3 Smoke Compartments

802.4 Interior Finish

802.5 Guards

802.6 Fire Resistance Ratings

803 Fire Protection

803.1 Scope. Requirements are limited to the

work area unless specifically required to apply

to the whole floor.

803.1.1 In fully sprinklered buildings, the

corridor ratings may be reduced in accordance

with the IBC.

24

Page 25: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 8 - Alterations Level 2

803 Fire Protection

803.2 Automatic Sprinklers

803.3 Standpipes

803.4 Fire Alarm and Detection

804 Carbon Monoxide Detection. Any work area in

Group I-1, I-2, I-4 and R occupancies shall be

equipped with carbon monoxide alarms in

accordance with 2018 IBC Section 1103.9.

Exceptions: 1. Work involving exterior surfaces. 2

Installation, alteration or repairs of plumbing or

mechanical systems other than fuel-burning

appliances.

25

Page 26: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 8 - Alterations Level 2

805 Means of Egress. The means of egress shall comply

with this section.

Exceptions:

1. Where the work area and the means of egress serving it complies with NFPA 101.

2. Means of egress complying with the requirements of the building code under which the building was constructed shall be considered to be compliant means of egress if, in the opinion of the code official, they do not constitute a distinct hazard to life.

● 805.3 Number of Exits

● 805.4 Egress doorways

● 805.5 Openings in Corridor Walls

● 805.6 Dead end corridors

● 805.7 Means of Egress lighting

● 805.8 Exit Signs

● 805.9 Handrails

● 805.10 Refuge Areas

● 805.11 Guards

26

Page 27: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 8 - Alterations Level 2806 Structural

807 Electrical. Newly installed electrical equipment and wiring related to work done in any work area shall comply with all applicable requirements of NFPA 70 except as provided in 807.3.

807.2 Existing wiring in all work areas in Group A-1, A-2, A-3, H and I occupancies shall be upgraded to meet the material and methods requirements of Chapter 7.

807.3 Residential occupancies

808 Mechanical

809 Plumbing. Where occupant load of the story is increased by more than 20 percent, plumbing fixtures shall be provided in quantities specified in the UPC based on the increased occupant load.

810 Energy Conservation. Level 2 alterations to existing buildings or structures are permitted without requiring the entire building or structure to comply with the energy requirements of the IECC or IRC… The alterations shall conform to the energy requirements of the IECC or IRC as they relate to new construction only.

27

Page 28: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 9 - Alterations Level 3901.2. Compliance. In addition to the provision of this chapter, work shall comply with all the requirements of Chapter 7 & 8.

The requirements of Section 802, 803 and 804 shall apply within all work areas whether or not they include exits and corridors shared by more than one tenant and regardless of the occupant load.

Exception: Buildings in which the reconfiguration of space affecting exits or shared egress access is exclusively the result of compliance with the accessibility requirements of Section 305.7 shall not be required to comply with Chapter 9.

902.1 Highrise buildings

902.2 Boiler and furnace equipment rooms

903.1 Existing shafts and vertical openings

903.2 Fire Partitions in Group R-3

903.3 Interior finish in exits serving the work area shall comply with Section 804.2 between the highest floor on which there is a work area to the floor of exit discharge.

28

Page 29: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 9 - Alterations Level 3

904 Fire Protection

904.1 Automatic Sprinklers shall be required in the

work area required by Section 802.2 or this section.

904.1.1 Highrise buildings

904.1.2 Rubbish & Linen chutes

904.1.3 Upholstered furniture or mattresses in Group F-1> 2500 sq.ft, Group M> 5000 sq.ft, Group S-1> 2500 sq.ft.

904.1.4 Other required automatic sprinklers. Work areas listed in IBC Table 903.2.11.6 having exits or corridors shared by more than one tenant or corridors serving occupant load greater than 30.

904.2 - Fire alarm and detection systems. Additional manual fire alarm, notification, and automatic fire detection when required in IBC.

905 Means of Egress. Additional exit lighting and exit signage to comply with IBC.

906 Structural

907 Energy Conservation - Alteration must comply

29

Page 30: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 10 - Change of Occupancy

1002 - Special Use & Occupancy - Compliance

with the Building Code

● Covered mall buildings● Atriums● Motor vehicle related occupancies● Aircraft related occupancies● Motion picture projection rooms● Stages and platforms● Special amusement buildings● Incidental use areas● Hazardous materials● Ambulatory care facilities● Group I-2 occupancies.

1003 Building Elements and Materials

1004 Fire Protection

1005 Means of Egress

1006 Structural - Seismic analysis required when building is assigned a higher risk category

1007 Electrical

1008 Mechanical

1009 Plumbing

1010 Other - Light & Ventilation30

Page 31: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 10 - Change of occupancy

1011.1.1 - Compliance with (IBC) Chapter 9

1011.1.1.1 - Change of occupancy

classification without separation

1011.1.1.2 Change of occupancy classification

with separation.

1011.1 General

1011.2 Fire Protection Systems

1011.3 Interior finish

1011.4 Means of Egress

1011.5 Heights and Area

1011.6 Exterior Wall Fire Resistance

1011.7 Enclosure of Vertical Shafts31

Page 32: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 11 - Additions

User Note - Very important. Says Chapter 11

gives exceptions where full compliance with

IBC is not required.

1102 Heights and Areas

1103 Structural

1104 Smoke Alarms in Occupancy Groups R

and I-1.

1105 Carbon Monoxide Alarms in Groups I-1, I-

2, I-4 and R

1106 Storm Shelters

1107 Energy Conservation. 32

Page 33: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 12 - Historic BuildingsAny building or structure that is one or more of the following:Listed or certified as eligible for listing, by the State Historic Preservation officer or the Keeper of the National Register of Historic Places, in the National Register of Historic Places.

Designated as historic under an applicable state or local law

Certified as a contributing resource within a National Register, state designated or locally designated historic district.

401.1 Repairs to Historic Buildings need only

comply with Chapter 12.

1201 General

1202 Repairs

1203 Fire Safety

1204 Change of Occupancy

1205 Structural

1206 Relocated Buildings33

Page 34: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Chapter 14 & 15

14 - Relocated or Moved Buildings

● 1401 General

● 1402.1 Location on the lot

● 1403.2 Foundation

● 1402.3 Wind Loads

● 1402.4 Seismic Loads

● 1402.5 Snow Loads

● 1402.6 Flood Hazard Areas

● 1402.7 Required Inspection and Repairs

15 Construction Safeguards

● 1501 General

● 1502 Protecting Adjacent Property

● 1503 Temporary Use of Streets/ Alleys

● 1504 Fire Extinguishers

● 1505 Means of Egress

● 1506 Standpipes

● 1507 Sprinkler System

● 1508 Accessibility

● 1509 Water Supply for Fire Protection34

Page 35: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Case Study - Remodel unsprinklered bar

The adjacent 1500 sq.ft. retail space next to an existing 2800 sq ft. bar has just become available in a 30 year old unsprinklered strip shopping center. The bar very much wants to take over this space.

Remodel consists of ……. Cosmetic remodel of existing space. Additional electrical around the bar for new bar equipment. New openings in the demising wall. Former retail space will be used for additional customer seating.

Original Code of Record? 1988 UBC

Alteration Level?

Existing 2800 sq.ft. - Level 1

New 1500 sq.ft. - Level 2

Change of Occupancy? Existing - No

Former retail space - Yes.

Addition? No. (building footprint is the same)

35

Page 36: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

IEBC - Performance Basis - Point System

Performance in three major criteria:

1. FIRE SAFETY

2. MEANS OF EGRESS

3. GENERAL SAFETY

Required minimum number of points based on

Table 1301.8

36

Page 37: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

CHAPTER 13 Performance Compliance Methods

37

Page 38: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Origins of Performance ComplianceNational Bureau of Standards / GSA /NIST

NFPA 101A

Fire Safety Evaluation

Compliance Alternatives

Performance Compliance Methods

38

Page 39: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Turning Back Time

NFPA 101A is widely used by the

us general services administration

same method as IEBC chapter 13

39

Page 40: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Converting Use Group M to A-3 Church

Example of using Chapter 13 for a change in

occupancy. Retail space is being converted to

assembly space.

40

Page 41: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

First Steps are Boots on the Ground

Going to A-3 Church

7,200 square feet

Type IIB

No internal fire resistance ratings

Meets allowable height and area

General Fire Alarm with Pull Stations

No detection system

Non-sprinklered

No standpipes

Good Means of Egress

41

Page 42: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Record the Data

Use the summary sheet:

Table 1301.7

42

Page 43: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Area Value

The Tabular Area for Type II = 9,200 sq ft

Open perimeter value was 0.75

Area Value =

9,200 + (9,200 x 0.75) / 1,200 = 13.4

43

Page 44: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Height and Height Points (single story)

Height value =

(3 -1) x 1 = 2

44

Page 45: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Various other values for more complicated buildings

Compartmentation

Tenant and Dwelling Units

Corridor Walls

Vertical Openings

45

Page 46: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

HVAC

Points are given for compliant HVAC

systems;

5 points

46

Page 47: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Fire Alarm and Detection System

Big deduction for no detection = - 10

Zero points for plain fire alarm with pull station.

47

Page 48: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Means of Egress PointsPoints based on:

Assumed:

No dead ends

Short Travel Distance

Good MOE lighting

48

Page 49: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

RESULTS Record the results on the “scoreboard.”

Determine what can be done to come into

compliance.

49

Page 50: Introduction to the 2018 International Existing Building ... · • IBC Chapter 34 was deleted in the 2015 IBC ... 408 Plumbing. Plumbing materials and suppl ies shall not be used

Why use the IEBC ?

• IBC Chapter 34 was deleted in the 2015 IBC

• LV City has been using the 2012 IEBC since 2014

• All Valley jurisdictions have now adopted 2018 IEBC

• IEBC should be the starting point for all existing buildings

50