Supplement A to Operating Manual EMI Test Receiver ESPI3 ...
Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3...
Transcript of Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3...
![Page 1: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/1.jpg)
RIGOL TECHNOLOGIES,INC.
Introduction to S1210 EMI Pre-Compliance
Test Software
Edward Pan
Rev.1.0
2017-OCT
![Page 2: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/2.jpg)
RIGOL TECHNOLOGIES, INC.
S1210 EMI Test Solution
S1210 EMI Pre-Compliance Test Software
![Page 3: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/3.jpg)
RIGOL TECHNOLOGIES, INC.
• Implement EMI Pre-Compliance testing to find root causes of circuitry problem.
• Simplify the Pre-Compliance testing procedure based on complicated testing
environment.
• Predict Pass/Fail result in front of different kinds of EMI testing standards before
sending to formal compliance testing.
• Save your constrained budget under highly competitive market.
Product Highlights
![Page 4: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/4.jpg)
RIGOL TECHNOLOGIES, INC.
• Amplitude Calibration Function
• Standard Limited Line Setting Function
• Sweep Function
• Peak Value Search Function
• Test Report Generation
• Graphic Type Operation
• Peak and Marker Table
• Multi-Display Mode
• Support Demo Mode
Product Features
![Page 5: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/5.jpg)
RIGOL TECHNOLOGIES, INC.
• Pre-define and preview the calibration data and curve
• Self-edit limited line and support two limited line simultaneously
• Support inconsecutive segment sweep function
• Support both conducted and radiated inspection
• Support peak table and marker table
• User-friendly testing report generation
• Support two traces graphical comparison
• Demo Mode offering
Exclusive Advantages
![Page 6: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/6.jpg)
RIGOL TECHNOLOGIES, INC.
• Easily observe the testing data via PC Laptop
• Intuitive testing and calibration concepts to implement different projects.
• Fit multiple EMI international standards via self-edited limit line
• Clear testing result and logical report
• Easily self-adjusted graphical environment to fit users observation
• Apparent and detailed analysis logistics and methodologies.
User Benefits
![Page 7: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/7.jpg)
RIGOL TECHNOLOGIES, INC.
Demo Procedure
![Page 8: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/8.jpg)
RIGOL TECHNOLOGIES, INC.
Required Equipment List
1. DSA875/832/832E/815/710/705 Spectrum Analyzer
2. EMI-DSA800 Option
3. Ultra Sigma Software
4. S1210 EMI Pre-Compliance Test Software
5. NFP-3 Near Field Probe ( For Radiated Test Only )
6. USB A Type to B Type Cable x 1
7. Personal Computer ( With WIN10/8/7/Vista System )
8. EMI DUT Source
![Page 9: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/9.jpg)
RIGOL TECHNOLOGIES, INC.
Use “A to B” Type USB cable to connect Spectrum Analyzer and
PC
Spectrum Analyzer Pre-Setup
A Type Connector
B Type Connector
![Page 10: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/10.jpg)
RIGOL TECHNOLOGIES, INC.
Use NFP-3 Near Field Probe and connect to DSA800 Spectrum
Analyzer
Spectrum Analyzer Pre-Setup
NFP-3 Near Field Probe Set
Connect to DSA800
![Page 11: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/11.jpg)
RIGOL TECHNOLOGIES, INC.
Spectrum Analyzer Setup
1. Press “Preset” on DSA800 firstly to original settings
![Page 12: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/12.jpg)
RIGOL TECHNOLOGIES, INC.
Spectrum Analyzer Setup
2. Press “ FREQ” and Setup “Start” (30MHz), “Stop”(1GHz) frequency on
DSA800
3. Press “BW/Det” and adjust the RBW value to 100KHz
![Page 13: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/13.jpg)
RIGOL TECHNOLOGIES, INC.
Spectrum Analyzer Setup
4. Press “AMPT” on DSA800, and Set the Vertical Axis
Units to “dBuV”
![Page 14: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/14.jpg)
RIGOL TECHNOLOGIES, INC.
5. Start the S1210 EMI Software
6. Press “File” and press ”New” to open a project “test_0”
Spectrum Analyzer Setup
![Page 15: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/15.jpg)
RIGOL TECHNOLOGIES, INC.
7. Select “test_0” and go to “Device” to connect PC to Spectrum, as you can see
the green USB Address will be shown on the bottom side of the screen
Spectrum Analyzer Setup
![Page 16: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/16.jpg)
RIGOL TECHNOLOGIES, INC.
8. Go to “Scan Config” and select the Limited Line 1 file
( EN55011_CAG1_Radiated_Qpeak_10m.lim )
9. Set the detector as “Peak”, RBW value to “100KHz”,
and select “Clear/Write” when complete
8
9
Spectrum Analyzer Setup
![Page 17: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/17.jpg)
RIGOL TECHNOLOGIES, INC.
10. Go to “Segment Config” and Setup the frequency sweeping segment
Start from 30MHz to 1GHz, RBW to 100KHz, Sweep time to 0 sec.
Spectrum Analyzer Setup
![Page 18: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/18.jpg)
RIGOL TECHNOLOGIES, INC.
11. Use NFP-3 Near Field Probe to approach the left side of DSA800 LCD
Display. ( To inspect the EMI source from CCFL Adaptor of LCD Back
light module)
Spectrum Analyzer Setup
![Page 19: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/19.jpg)
RIGOL TECHNOLOGIES, INC.
12. Go to “Measure” and implement the “Pre-Scan”
13. The EMI Spectral Lines are shown on the screen
Spectrum Analyzer Setup
![Page 20: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/20.jpg)
RIGOL TECHNOLOGIES, INC.
Back up
![Page 21: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/21.jpg)
RIGOL TECHNOLOGIES, INC.
S1210 EMI Test Solution
Double click the mouse on the graphic and the markers will
shown on the screen and the marker table as well.
![Page 22: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/22.jpg)
RIGOL TECHNOLOGIES, INC.
S1210 EMI Test Solution
Go to “Set Reference” and users can do two trace comparison
![Page 23: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/23.jpg)
RIGOL TECHNOLOGIES, INC.
S1210 EMI Test Solution
Users can “Zoom In” the dedicated peak and observe inside
![Page 24: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/24.jpg)
RIGOL TECHNOLOGIES, INC.
S1210 EMI Test Solution
The Zoom In Spectral Lines
![Page 25: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/25.jpg)
RIGOL TECHNOLOGIES, INC.
How to edit the
Limit Line?
![Page 26: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/26.jpg)
RIGOL TECHNOLOGIES, INC.
How to edit the limit line?
1. Press the “Data Manager” at the top of the display
![Page 27: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/27.jpg)
RIGOL TECHNOLOGIES, INC.
How to edit the limit line?
2. Select the “limit.lim” file
![Page 28: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/28.jpg)
RIGOL TECHNOLOGIES, INC.
How to edit the limit line?
3. Edit the limit line parameters at right side window.
![Page 29: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/29.jpg)
RIGOL TECHNOLOGIES, INC.
How to edit the limit line?
4. Export and save the file
![Page 30: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/30.jpg)
RIGOL TECHNOLOGIES, INC.
How to edit the limit line?
5. Select one folder to export and save file
![Page 31: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/31.jpg)
RIGOL TECHNOLOGIES, INC.
How to edit the limit line?
6. User can see the limit line file inside and folder and can
import to S1210 Software by “Scan Config” setup item.
![Page 32: Introduction to S1210 EMI Pre-Compliance Test …...S1210 EMI Pre-Compliance Test Software 5. NFP-3 Near Field Probe ( For Radiated Test Only ) 6. USB A Type to B Type Cable x 1 7.](https://reader035.fdocuments.us/reader035/viewer/2022062318/5fd2aef0b37347702d2c2f56/html5/thumbnails/32.jpg)
RIGOL TECHNOLOGIES, INC.
THANK YOU