If you can't read please download the document

Transcript of Introduction to ARIA IP - 60 Anton Hattingh. Content System overview Connection diagram System...

  • Slide 1
  • Introduction to ARIA IP - 60 Anton Hattingh
  • Slide 2
  • Content System overview Connection diagram System Recourses Connections Hardware Features
  • Slide 3
  • Hybrid telephone system with 12 analog PSTNs & 48 ext. Caller ID service for CO line & SLT Conference, SMDR, LCR, Call duration control Collect call barring, Mobile extension Other services for enterprise communications - Alarm detection - External door phone control - External paging interface, - External music source interface System overview
  • Slide 4
  • General connection diagram
  • Slide 5
  • System Resources 1/2 DESCRIPTIONCAPACITY/BOARDTOTAL Time Slots128 CO Line Ports3/MBU, 3/EMBU, 3/CHB308, 3/CSB316, 8/VOIB, 30/E1HB8 Max. 36 Max Direct Station (DKT, SLT, DSS) Connections 8/MBU, 8/EMBU, 8/CHB308, 16/CSB316, 8/VOIB, 8/E1HB8 Max. 48 Max. Door2/MBU, 2/EMBU4 LANMBU, VOIB, E1HB83 MODEM Channel1/MODU1 Attendant Positions5/System Intercom LinksNon-Blocking Paging - All Call - Internal 1 zone 5 zones Station Speed Dial100/station, 24 digits each500 System Speed Dial24 digits each500 Last Number Redial15 ~ 50(by admin programming)32 digits
  • Slide 6
  • System Resources 2/2 DESCRIPTIONCAPACITY/BOARDTOTAL CO Line Group88 Station Group10 Conference3~15 PartyAll ports are available Multi-Conference3~15 PartyMax. 3 groups Internal MOH (13 Music Sources) 1/MBU1 External MOH1/MBU1 External Paging port1/MBU1 External Relay Contact2/MBU, 2/EMBU4 Alarm Input1/MBU1 RS-232C Port1/MBU1 DTMF/CPT Receiver channels 16 chs/MBU16 chs FSK Receiver channels16 chs/MBU16 chs PFT Circuit1/MBU, 1/EMBU, 1/CHB308, 1/CSB3164
  • Slide 7
  • MBU connectors and LED Available Option: 1. CN2 : E1HB8, CHB308, CSB316 or SLIB8 2. CN4 : MODU 3. CN5 : VMIU or AAFU 4. CN14: VOIB 5. CN9 & CN10: CMU50PR or CMU12PR LD1 : System running indication LD2-4 : S/W task indication SW1 : Default ON Pole1 : reserved Pole2 : system trace on Pole3 : reserved Pole4 : system backup SW2 : Backup battery ON for protection Status LED
  • Slide 8
  • System Connections RJ-11 1: N/A 2: DKT-Tip 3: SLT-Tip or CO-Tip 4: SLT-Ring or CO-Ring 5: DKT-Ring 6: N/A CO# : Loop start CO Port STA# : Hybrid Port DKT# : DKTU Only Port SLT# : SLT Only Port BKSU EKSU BKSU Only
  • Slide 9
  • Connector Pin-out 1/3 NOTEWhen installing DKT or SLT on Hybrid Ports, (MJ2-2,3,4,5,6,7,8), keep the above pin assignment. Otherwise the DKT or SLT will not operate normally. MBU (CO) Connector PIN NumberNOSignal Name RJ111,2N/A 3,4CO-T, CO-R 5,6N/A MBU (Extension) DKT ONLY CONNECTORPIN NUMBERNOSIGNAL NAME RJ111N/A 2DKT-T 3,4ALARM_Detection 5DKT-R 6N/A MBU (Hybrid) CONNECTORPIN NUMBERNOSIGNAL NAME RJ111N/A 2DKT-T 3,4SLT-T, SLT-R 5DKT-R 6N/A
  • Slide 10
  • Connector Pin-out 2/3 TERMINAL DKT CONNECTORPIN NUMBERNOSIGNAL NAME RJ111N/A 2RING 3,4Reserved 5TIP 6N/A TERMINAL SLT CONNECTORPIN NUMBERNOSIGNAL NAME RJ111,2N/A 3,4TIP, RING 5,6N/A
  • Slide 11
  • Connector Pin-out 3/3 CN13 Pin Assignment (Relay Contact) CONNECTOR NOSIGNAL NAME 4 PIN1Relay 1-pin1 2Relay 1-pin2 3Relay 2-pin1 4Relay 2-pin2 MJ3 Pin Assignment (LAN) ConnectorPin NumberNOSIGNAL NAMEFUNCTION RJ454,5,7,8RESERVED 1TX+Transmit Data 2TX-Transmit Data 3RX-Receive Data 6RX+Receive Data
  • Slide 12
  • Terminal/SLT Cabling Distance
  • Slide 13
  • Expansion Card CHB308 External. Provides 3 circuits Loop start CO line interface. DTMF or pulse signaling to line Loop current detection FSK & DTMF CID detection. Call progress tone detections Internal. Provides 8 digital Stations or 8 SLT station circuits. FSK & DTMF CID detection and Generator. +36V Power Circuit for SLT feeding SLT feeding Current is 20mA at 900ohm loop impedance. CO Line and Hybrid Board (3 CO + 8 HYB)
  • Slide 14
  • Expansion Card CSB 316 CO Line and SLT Board (3 CO + 16 SLT) External. Provides 3 circuits Loop start CO line interface. DTMF or pulse signaling to line Loop current detection FSK & DTMF CID detection. Call progress tone detections. Internal. Provides 16 SLT station circuits. FSK & DTMF CID detection and Generator. +36V Power Circuit for SLT feeding SLT feeding Current is 20mA at 900ohm loop impedance.
  • Slide 15
  • Expansion Card SLIB 8 SLT Board (8 SLTs) Internal. Provides 8 SLT station circuits. FSK & DTMF CID detection and Generator. +36V Power Circuit for SLT feeding SLT feeding Current is 20mA at 900ohm loop impedance.
  • Slide 16
  • Expansion Card E1HB8 E1 Digital trunk & 8 Hybrid CN5 on the MBU, but not on the EMBU E1 digital trunk: maximum 30 CO lines at the same time 8 Hybrid ports that provide DKT or SLT connection 2.048Mbps E1 line as CAS(Channel Associated Signaling) HDB3 CODE DID, DOD, and TIE according to each countrys specifications Pulse dialing, DTMF dialing, and MFC-R2 signaling(30 channels at the same time) SLU8(Single Line Interface Unit: 8 ports CN6, CN7 on the E1HB8 +36V power circuit for SLT feeding Single Line Interface circuit: 8 EA
  • Slide 17
  • Add on board MODU MODEM function board MODU provides analogue modem connection. MODU should be installed on the CN4 Supports Bell, ITU-T, V.34, V.32BIS, V.90 Protocol 300bps up to 33Kbps speed rate Automatic rate negotiation Modem function board
  • Slide 18
  • Add on board VMIU VMIU provides 4 channel Record/Play VMIU provides Time & System prompt All message are saved in Flash memory Max record time - Prompt : 8 Min. - System greeting : 24 Min - User record time : 99 Min Max. Number of User Voice Message: 800ea Note : User Greeting does not lost by system power off or reset Note : User Greeting does not lost by system power off or reset because of this message is stored in FLASH memory because of this message is stored in FLASH memory Voice Mail Interface Unit
  • Slide 19
  • Add on board AAFU Auto Attendant Function Unit AAFU provides 4 channel Record/Play AAFU provides Time & System prompt All message are saved in Flash memory Max record time - Prompt : 8 Min. - System greeting : 24 Min - User record time : 9 Min Max. Number of User Voice Message: 800ea Note : User Greeting does not lost by system power off or reset Note : User Greeting does not lost by system power off or reset because of this message is stored in FLASH memory because of this message is stored in FLASH memory
  • Slide 20
  • Add on board VOIB & VOIU Voice over Internet Protocol Interface board ItemSpecification LAN Interface10 / 100 Base-T Ethernet(IEEE 802.3) Speed10 Mbps (Auto-Negotiation) DuplexHalf Duplex or Full Duplex(Auto-Negotiation) VoIP ProtocolH.323 Revision 2 Voice CompressionG.711/G.726/G729/G.723.1 Voice/Fax SwitchingT.38 Echo cancellationG.165 VOIB can be installed on the basic MBU Provides the Ethernet interface for S/W applications and VoIP features. Optional VoIP daughter board.(VOIU) Maximum Capacity: 8 channels -VOIB provides four(4) VoIP channels. -VOIU provides four(4) VoIP channels.
  • Slide 21
  • Add on board CMP50PR & CMU12PR Call Metering & Polarity Reversal Detection unit 50Hz and 12Hz CMU50PR (Call Metering-50 Hz & Polarity Reversal Detection unit) Provides 3 channels Call Metering detection for 50Hz Provides 3 channels of Polarity Reversal Detection It can be installed on the MBU, EMBU, CHB308 or CSB316 CMU12PR(Call Metering-12KHz & Polarity Reversal Detection unit) Provides 3 channels Call Metering detection for 12 KHz or 16Khz Provides 3 channels of Polarity Reversal It can be installed on the MBU, EMBU, CHB308 or CSB316
  • Slide 22
  • Proprietary Terminals MODELDESCRIPTION LDP-7224D3 Line LCD display, 24 Flexible Button,3 Soft keys, Navigation key LDP-7208D2 Line LCD Display, 8 Flexible Button LDP-7248DSS48 Button DSS Console LDP-DPBDoor Phone Box LDP-7248DSSLDP-Door phone LDP-7224D LDP-7208D Not Compatible with OptiCon IP and GDK Systems.
  • Slide 23
  • IP Terminals MODELDESCRIPTION LIP-7024LD3 Line LCD display, 24 Flexible Button,3 Soft keys, Navigation key, Dual LED,Calender,Scheduler LIP-7024D3 Line LCD display, 24 Flexible Button,3 Soft keys, Navigation key, Dual LED LIP-7016D3 Line LCD display, 16 Flexible Button,3 Soft keys, Navigation key, Dual LED LIP-7008D2 Line LCD Display, 8 Flexible Button LIP-7024DLIP-7016DLIP-7024LDLIP-7008D
  • Slide 24
  • Maintenance PSTN Dial-up Connection Off-site (Remote) Maintenance Data Network In-site maintenance Digital Terminal Admin Maintenance Console On-site & Off site maintenance through RS-232C, Ethernet, Modem On line PC Admin : DB up/download, Diagnostics, S/W upgrade, PC Admin Off line PC Admin (PC Admin Pro) Speed Editor for system speed dial User level admin program adjustable level program
  • Slide 25
  • Voice Mail / Auto Attendant Voice Mail SMS Notification to virtual extension (mobile extension) 4 ch. / Max. 100 min recording time/ 25 min greeting / 800 user message recording Max. 100 system greetings / Max. 25 min Optional Voice Mail and Auto-Attendant Auto-Attendant : 4 channels / 10 min recording / 25 min system greeting
  • Slide 26
  • Networking SIP / H.323 proxy registration Business models for SIP operator / Nortel IP platform ARIA IP 60 Voice Networking