introducing PATHWAY LIGHTING’S LED LUMINAIRESCost comparison above assumes labor cost is incurred...
Transcript of introducing PATHWAY LIGHTING’S LED LUMINAIRESCost comparison above assumes labor cost is incurred...
i n t r o d u c i n g
PATHWAYLIGHTING’S LED LUMINAIRES
t h e LED l i g h t i n g s o u r c e
Magner Sanborn Office, Spokane, WashingtonArchitect: Uptic StudiosPhotography: Shaun Cammack
p a t h w a y l i g h t i n g . c o mpage two
PATHWAY LIGHTING’S LED LUMINAIRES
S y n J e t
H e a t S i n k
F o r t i m o L E D D o w n l i g h t M o d u l e
X i t a n i u m D r i v e r
R e f l e c t o r / T r i m
1st in Class & Best in Class | As the first lighting manufacturer to integrate Philips’ Fortimo LED Downlight Module, Pathway has always been at the forefront of luminaire development, solving design and technical challenges associated with LED lighting application—thermal management, lamp life, color consistency, scalability, maintenance, and glare. Pathway is committed to eliminating design barriers and in working closely with lighting specifiers, to create functional, comfortable, memorable visual environments.
Thermal Management | in conjunction with a compact aluminum heat sink, all Fortimo LED Downlight Modules rated at 2000 initial lumens and higher are cooled by Nuventix’s SynJet active cooling module. The SynJet module—a low-power, effectively silent, advanced cooling technology—creates turbulent, pulsated air jets, which can be directed between the fins of the heat sink, resulting in high heat transfer coefficient air flows that provide optimum thermal operating environment for the Fortimo LED Downlight Module.
Color Consistency | remote phosphor technology, a color mixing chamber and tight LED binning work in concert to ensure color consistency from fixture to fixture, with no visible LEDs, and virtually no color shift over the life of the engine.
Scalability & Maintenance | all Pathway LED luminaires are engineered to accommodate future improvements in LED technology. As Philip’s Fortimo LED Downlight Modules continue to improve in performance, updating installed luminaires in the field will be as easy as replacing the Fortimo Module and/or its intelligent Xitanium driver—maintenance that is simple, familiar, and in all cases can be done from below the ceiling.
Include a complete line of recessed-, surface-, and pendant-mounted LED lighting solutions, engineered to provide lighting specifiers with reliable, high-performance, sustainable LED products.
DPR Construction Headquarters, Glenn Allen, VirginiaArchitect: Evolve ArchitecturePhotography: David Galen
T h e r m a l T r a n s f e r P a d
page four p a t h w a y l i g h t i n g . c o m
LED AS CFL DOWNLIGHT REPLACEMENT
… i t ’ s a b o u t t i m e
Light Output | when comparing CFL and LED downlights, it is important that the analysis is a true apples-to-apples comparison—one where lumen rating is discussed in terms of delivered lumens, not in terms of initial lumens, for both systems. Pathway Lighting’s design team uses today’s most advanced LED engines to deliver lumen output that exceeds the performance and equivalent efficacy of even the most efficient CFL downlight (approx. efficiency 70% or 45-50 lm/w) on the market today.
Life | superior thermal management leads to LED products that are rated at 50,000 hours to 70% light output (L70), which is four times the life of a typical CFL equivalent. Longer life means lower cost of ownership.
Dimmability | an intelligent LED driver that provides 0-10V dimming to 10% comes standard at no extra charge, making our LED systems cost competitive with CFL-based lighting fixtures running on expensive electronic dimming ballasts. Our products are compatible with major dimming control systems and protocols. Please contact factory for assistance and further information.
Sustainability | unlike CFL-based products, LEDs are mercury-free and consume less energy, creating a smaller ecological footprint.
Peace of Mind | all of our LED products are backed by an industry standard, 5-Year limited warranty.
Magner Sanborn Office, Spokane, WashingtonArchitect: Uptic Studios
Photography: Shaun Cammack
Solerio LED Pendant
P a t h w a y 6 V L E D 110 0 l m 3 2 W C F L 3 2 W C F L
lamp life 50,000 20,000 12,000
W/fixture 17 37 37
$/kWh $0.12 $0.12 $0.12
# hours/year @ 12 hr/Business Day
3132 3132 3132
kWh per year 53.24 115.88 115.88
energy cost per year $6.39 $13.91 $13.91
estimated lamp cost 80 15 15
driver or ballast cost 50 50 50
estimated labor cost 75 75 75
total cost of ownership – 5 years
$31.95 $69.53 $159.53
total cost of ownership – 10 years
$63.89 $229.06 $319.06
total cost of ownership – 15 years
$95.84 $513.59 $693.59
total cost of ownership – 20 years
$407.79 $673.12 $853.12
ope r a t i ng c o s t c ompa r i s on f o r e q u i va l en t C F L & L ED down l i gh t s
p r o d u c t a v e r a g e l i g h t l e v e l ( F C )
u n i f o r m i t y( m a x / m i n ) w / s q . f t .
Pathway 6VLED 1100 lm 17W
13.1 1.83:1 0.35
Pathway 6” 32W CFL Downlight
13.3 1.87:1 0.77
Brand A- 6” 32W CFL Downlight
13.0 1.91:1 0.73
Brand B- 6” 32W CFL Downlight
14.9 2.06:1 0.67
Brand C- 6” 32W CFL Downlight
11.6 2.01:1 0.75
c o r r i do r c a l c u l a t i on s
40’0”
8’0” o
.c. ty
p.
6’0”
p r o d u c t a v e r a g e l i g h t l e v e l ( F C )
u n i f o r m i t y( m a x / m i n ) w / s q . f t .
6” Round 34W LED Downlight 2000 lm (6VLED2000 Medium)
39.3 2.53:1 0.95
6” Round 42W CFL Downlight (6HF1 Open)
31.6 2.32:1 1.33
6” Round 42W CFL Downlight (6HF1 Lensed)
22.8 2.15:1 1.33
12’0”
6’0” o
.c. ty
p.
12’0”
sma l l c o n f e r en c e r oom c a l c u l a t i on
Cost comparison above assumes labor cost is incurred for each lamp, ballast or driver replacement. LED module and driver are replaced once during the 20-year period. CFL on 12 hour/start has a rated lamp life to 20,000 hours; lamp replaced in years 6, 12, 19. CFL on shorter on/off cycle has a rated life of 12,000 hours; lamp replaced in years 3, 7, 11, 15, 19. Ballast replaced once. All component and labor costs are based on market levels at the time of printing.
Ceiling height = 9’-0”. Room surface reflectances = 80/50/20. LLF = 0.85. Illuminance measurements taken at floor.
Ceiling height = 9’-0”. Room surface reflectances = 80/50/20. LLF = 0.85. Illuminance measurements taken at 30” AFF.
small conference room corridor
p a t h w a y l i g h t i n g . c o m p a t h w a y l i g h t i n g . c o m
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
4” SQUARERECESSED
DOWNLIGHT
4SQLED 1100 initial 4,000 k
914 delivered 3,500 k
3,000 k
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
4” SQUARERECESSED
WALLWASH
4SQLEDWW 1100 initial 4,000 k
523 delivered 3,500 k
3,000 k
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
6” ROUNDRECESSED
WALLWASH
6VLEDWW 1100 initial 4,000 k
960 delivered 3,500 k
3,000 k
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
4” ROUNDRECESSED
WALLWASH
4VLEDWW 1100 initial 4,000 k
903 delivered 3,500 k
3,000 k
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
6” SQUARERECESSED
WALLWASH
6SQLEDWW 1100 initial 4,000 k
679 delivered 3,500 k
3,000 k
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
6” SQUARERECESSED
DOWNLIGHT
6SQLED 1100 initial 4,000 k
1035 delivered 3,500 k
3,000 k
4 ” S Q U A R E A P E R T U R E , 110 0 L U M E N
c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g
c r i t e r i a
505
20151050 25 30
35
40
45
50
55
60
65
70
75
8085
90
442
378
315
252
189
126
63
0
4” square 1100 downlight
2015105 20 5 30
35
40
45
50
55
60
65
70
75
80
85
90
320
240
160
80
0
4” square 1100 wall wash
8.0' 13.7 14.8’
10.0' 7.4 18.5’
12.0' 4.6 22.2’
14.0' 3.1 25.9’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g
c r i t e r i a
6 ” S Q U A R E A P E R T U R E , 110 0 L U M E N
c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g
c r i t e r i a
8.0' 27.4 10.2’
10.0' 14.7 12.7’
12.0' 9.2 15.3’
14.0' 6.3 17.8’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g
c r i t e r i a
page six page seven
c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g
c r i t e r i a
8.0' 33 9.8’
10.0' 17.8 12.3’
12.0' 11.1 14.7’
14.0' 7.6 17.2’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
4” ROUNDRECESSED
DOWNLIGHT
4VLED 1100 initial 4,000 k
941 delivered 3,500 k
3,000 k
c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g
c r i t e r i a
c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g
c r i t e r i a
8.0' 58.2 6.0’
10.0' 31.3 7.5’
12.0' 19.5 9.0’
14.0' 13.3 10.5’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
6” ROUNDRECESSED
DOWNLIGHT
6VLED 1100 initial 4,000 k
971 delivered 3,500 k
3,000 k
c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g
c r i t e r i a
4 ” R O U N D A P E R T U R E , 110 0 L U M E N
6 ” R O U N D A P E R T U R E , 110 0 L U M E N
1.091.09
754
20151050
25
30
35
40
45
50
55
60657075808590
660
566
472
377
283
189
94
6” square 1100 downlight 6” square 1100 wall wash
40045
50
55
65
70
80
85
40
60
75
90
300
200
100
0
20151050 25 30 35
1.051.05
20151050 25
30
35
40
45
50
55
60657075808590
888
777
666
555
444
333
111
222
4” round 1100 downlight 4” round1100 wall wash
20151050 25 30
35
40
45
50
55
60
65
70
75
8085
90
973
730
487
243
0
.67.67
1565
1761
1369
1174
978
782
587
391
196
0
20
151050
25
30
35
4045505560657075808590
6” round 1100 downlight
312
469
625
781
937
1093
1250
156
0
20151050
45
50
55
65
70
80
85
40
35
30
25
60
75
90
6” round 1100 wall wash
54.754.7 27.5
27.5
62.062.037.137.1
56.356.3 54.1
54.1
58.258.257.557.5
DISTANCE FROM
CEILING
3’ O.C.; 3’ Set Back
Below Fixtures
Between Fixtures
1’ 5 4
2’ 8 8
3’ 7 8
4’ 7 8
5’ 6 7
6’ 4 5
7’ 3 3
8’ 2 3
9’ 2 2
10’ 1 1
DISTANCE FROM
CEILING
3’ O.C.; 3’ Set Back
Below Fixtures
Between Fixtures
1’ 5 4
2’ 10 7
3’ 9 11
4’ 9 10
5’ 7 8
6’ 5 6
7’ 4 4
8’ 3 3
9’ 2 2
10’ 2 2
DISTANCE FROM
CEILING
3’ O.C.; 3’ Set Back
Below Fixtures
Between Fixtures
1’ 6 6
2’ 8 9
3’ 7 8
4’ 6 6
5’ 6 7
6’ 5 7
7’ 5 6
8’ 4 5
9’ 3 4
10’ 3 3
DISTANCE FROM
CEILING
3’ O.C.; 3’ Set Back
Below Fixtures
Between Fixtures
1’ 4 4
2’ 9 10
3’ 8 8
4’ 9 10
5’ 8 9
6’ 7 7
7’ 5 6
8’ 5 5
9’ 4 4
10’ 3 3
0=1.110=1.11
90=1.0490=1.04
0=1.200=1.20
90=1.1190=1.11
0=0.830=0.83
90=1.0590=1.05
0=0.660=0.66
90=0.6990=0.69
vertical FC on wall vertical FC on wall
vertical FC on wall vertical FC on wall
p a t h w a y l i g h t i n g . c o m p a t h w a y l i g h t i n g . c o m page nine
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
6” ROUNDRECESSED
WALLWASH
6VLEDWW 2000 initial 4,000 k
1748 delivered 3,500 k
3,000 k
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
4” ROUNDRECESSED
WALLWASH
4VLEDWW 2000 initial 4,000 k
1497 delivered 3,500 k
3,000 k
c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g
c r i t e r i a
8.0' 60.6 9.6’
10.0' 32.6 12.0’
12.0' 20.3 14.4’
14.0' 13.9 16.8’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
4” ROUNDRECESSED
DOWNLIGHT
4VLED 2000 initial 4,000 k
1704 delivered 3,500 k
3,000 k
c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g
c r i t e r i a
c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g
c r i t e r i a
8.0' 104.8 6.0’
10.0' 56.4 7.5’
12.0' 35.1 9.0’
14.0' 24.0 10.5’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
6” ROUNDRECESSED
DOWNLIGHT
6VLED 2000 initial 4,000 k
1766 delivered 3,500 k
3,000 k
c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g
c r i t e r i a
4 ” R O U N D A P E R T U R E , 2 0 0 0 L U M E N
6 ” R O U N D A P E R T U R E , 2 0 0 0 L U M E N
1.041.04
.68.68
20151050 25
35
40
30
45
50
55
60657075808590
1629
1426
1222
1018
815
611
204
407
4” round 2000 downlight 4” round 2000 wall wash
40
60
75
90
1200
1500
900
600
300
20151050 25 30 35
45
50
55
65
70
80
85
2819
3171
2466
2114
1762
1409
1057
705
352
0
20
151050
25
30
35
4045505560657075808590
6” square 2000 downlight
640
480
320
160
0
20151050 25 30 35
45
50
55
65
70
80
85
40
60
75
90
6” square 2000 wall wash
49.749.7 41.5
41.5
51.551.548.048.0
DISTANCE FROM
CEILING
3’ O.C.; 3’ Set Back
Below Fixtures
Between Fixtures
1’ 10 9
2’ 14 15
3’ 11 13
4’ 10 10
5’ 9 11
6’ 9 10
7’ 8 9
8’ 7 7
9’ 6 6
10’ 4 5
DISTANCE FROM
CEILING
3’ O.C.; 3’ Set Back
Below Fixtures
Between Fixtures
1’ 7 7
2’ 16 17
3’ 14 15
4’ 16 17
5’ 14 17
6’ 12 13
7’ 10 11
8’ 8 9
9’ 7 7
10’ 6 6
0=0.810=0.81
90=1.0590=1.05
0=0.660=0.66
90=0.7090=0.70
vertical FC on wall
vertical FC on wall
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
4” SQUARERECESSED
WALLWASH
4SQLEDWW 2000 initial 4,000 k
955 delivered 3,500 k
3,000 k
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
4” SQUARERECESSED
DOWNLIGHT
4SQLED 2000 initial 4,000 k
1662 delivered 3,500 k
3,000 k
page eight
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
6” SQUARERECESSED
WALLWASH
6SQLEDWW 2000 initial 4,000 k
1129 delivered 3,500 k
3,000 k
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
6” SQUARERECESSED
DOWNLIGHT
6SQLED 2000 initial 4,000 k
1547 delivered 3,500 k
3,000 k
4 ” S Q U A R E A P E R T U R E , 2 0 0 0 L U M E N
c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g
c r i t e r i a
8.0' 24.2 14.8’
10.0' 13.0 18.5’
12.0' 8.1 22.2’
14.0' 5.5 25.9’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g
c r i t e r i a
6 ” S Q U A R E A P E R T U R E , 2 0 0 0 L U M E N
c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g
c r i t e r i a
8.0' 49.8 10.2’
10.0' 26.8 12.7’
12.0' 16.7 15.3’
14.0' 11.4 17.8’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g
c r i t e r i a
1.091.09
918
20151050 25 30
35
40
45
50
55
60
65
70
75
8085
90
803
688
574
459
344
229
115
0
4” square 2000 downlight
600
20151050 25 30
35
40
45
50
55
60
65
70
75
8085
90
450
300
150
0
4” square 2000 wallwash
1372
20151050
25
30
35
40
45
50
55
60657075808590
1200
1029
857
686
514
343
171
6” square 2000 downlight
640
480
320
160
0
20151050 25 30 35
45
50
55
65
70
80
85
40
60
75
90
6” square 2000 wall wash
48.548.5 26.2
26.2
43.943.932.232.2
DISTANCE FROM
CEILING
3’ O.C.; 3’ Set Back
Below Fixtures
Between Fixtures
1’ 8 7
2’ 14 13
3’ 14 14
4’ 13 15
5’ 11 13
6’ 8 9
7’ 6 6
8’ 4 5
9’ 3 4
10’ 3 3
DISTANCE FROM
CEILING
3’ O.C.; 3’ Set Back
Below Fixtures
Between Fixtures
1’ 7 6
2’ 11 11
3’ 14 15
4’ 14 17
5’ 12 13
6’ 9 10
7’ 7 7
8’ 5 5
9’ 4 4
10’ 3 3
0=1.170=1.17
90=1.0290=1.02
0=1.140=1.14
90=1.1490=1.14
vertical FC on wall
vertical FC on wall
p a t h w a y l i g h t i n g . c o m
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
PENDANT WITH
ACRYLIC REFRACTOR
SHADE
P2MLD2 2000 initial 4,000 k
1613 delivered 3,500 k
3,000 k
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
8” APERTURECYLINDER
surface:C2SLED
2000 initial 4,000 k
pendant:C2PLED
1774 delivered 3,500 k
wall:C2WLED
3,000 k
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
6” APERTURECYLINDER
surface: C65SLED
1100 initial 4,000 k
pendant:C65PLED
971 delivered 3,500 k
wall:C65WLED
3,000 k
d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )
c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )
8” APERTURECYLINDER
surface:C3SLED
2000 initial 4,000 k
pendant:C3PLED
1774 delivered 3,500 k
wall:C3WLED
3,000 k
page ten page eleven
S E R I E S C 6 5
c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g
c r i t e r i ac a n d e l a
d i s t r i b u t i o n c o n e o f l i g h t s p a c i n g c r i t e r i a
S E R I E S C 2 S
c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g
c r i t e r i a
8.0' 79.1 4.9’
10.0' 41.3 6.8’
12.0' 25.3 8.6’
14.0' 17.1 10.5’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g
c r i t e r i a
8.0' 58.9 4.1’
10.0' 30.9 5.6’
12.0' 19.0 7.2’
14.0' 12.8 8.9’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
S O L E R I O P E N D A N T
8.0' 79.1 4.9’
10.0' 41.3 6.8’
12.0' 25.3 8.6’
14.0' 17.1 10.5’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
20151050 25 30
35
40
45
50
55
60
65
70
75
8085
90
942
1177
1413
1648
1884
2119
235
471
706
0
C2 & C3
1200
1500
900
600
300
0
20151050 25 30 35
40
45
50
55
60
65
70
75
80
85
90
Solerio Pendant
42.242.4
.76.76
S E R I E S C 3 S
8.0' 58.2 6.0’
10.0' 31.3 7.5’
12.0' 19.5 9.0’
14.0' 13.3 10.5’
CEILING HEIGHT FC (NADIR) BEAM DIA.
Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.
58.258.2
.67.67
48.748.7
.93.93
48.748.7
.93.93
1565
1761
1369
1174
978
782
587
391
196
0
20
151050
25
30
35
4045505560657075808590
C65
k e y w o r ds e a r c h s e r i e s l u m e n s c o l o r
t e m p e r a t u r ei n p u t
v o l t a g e m o u n t i n g o p t i o n s o p t i o n a l f i n i s h e s f o r c y l i n d r i c a l h o u s i n g o p t i o n s / a c c e s s o r i e s
P2MLD2 P2M = pendant with acrylic
refractor shade
LD2 = 2000 lumens
4K (4000K)
35K (3500K)
3K (3000K)
blank = 120/277
volt standard
C = adjustable aviation cable & 10’
coiled cord
S = adjustable aviation cable & 10’ straight
cord
P = pendant, for use with separate
pendant kit
PH = power hook
F = fuse blank = satin anodized aluminum
W = matte white
B = matte black
Z = bronze
SA = satin aluminum
MA = glossy metallic aluminum
mounting kits for pendant hung cylinders:
PK24 = 24” pendant kit
PK36 = 36” pendant kit
PK48 = 48” pendant kit
PK60 = 60” pendant kit
k e y w o r d s e a r c h s e r i e s l u m e n s c o l o r
t e m p e r a t u r ei n p u t
v o l t a g e o p t i o n s / a c c e s s o r i e s r e f l e c t o r f i n i s h t r i m f l a n g e f i n i s h
d e c o r a t i v e a c c e s s o r i e s
4SQLED 4SQLED = 4” square aperture
downlight
1100
2000
4K (4000K)
35K (3500K)
3K (3000K)
blank = 120/277
volt standard
EM = emergency operation
hanger bars:
9127 = 27” c-channel
9152 = 52” c-channel
27BH = 27” solid bar
101782 = caddy #520
4SQLED = 4” square reflector
SCL = soft specular clear alzak
SWT = soft specular wheat
SST = soft specular straw
SPW = soft specular pewter
SBZ = soft specular bronze
SBL = soft specular black
see additional reflector finishes on next page.
PF = polished self flange
blank = matte white flange
IC4 = suspended 4” square ICE lens
4SQLEDWW 4SQLEDWW = 4” square aperture
wall wash
4SQLEDWW = 4” square wall wash reflector
6SQLED 6SQLED = 6” square aperture
downlight
6SQLED = 6” square reflector
IC6 = suspended 6” square ICE lens
6SQLEDWW 6SQLEDWW = 6” square aperture
wall wash
6SQLEDWW = 6” square wall wash reflector
4VLED 4VLED = 4” round aperture downlight
4VLED = 4” round downlight reflector
IC4 = suspended 4” round ICE lens
4VLEDWW 4VLEDWW = 4” round aperture
wall wash
4VLEDWW = 4” round wall wash reflector
6VLED 6VLED* = 6” round aperture downlight
6VLED = 6” round downlight reflector
IC6 = suspended 6” round ICE lens
6VLEDWW 6VLEDWW = 6” round aperture
wall wash
6VLEDWW = 6” round wall wash reflector
k e y w o r d s e a r c h s e r i e s m o u n t i n g o p e r a t i o n l u m e n s c o l o r
t e m p e r a t u r ei n p u t
v o l t a g e o p t i o n s / a c c e s s o r i e s o p t i o n a l c y l i n d e r f i n i s h e s r e f l e c t o r f i n i s h t r i m f l a n g e
f i n i s h
C65SLED C65* = 6” aperture cylinder,
8” diam. X 12.6” tall
S = surface mount
P = pendant,
for use with separate
pendant kit
W = wall mount
LED = led operation
1100
2000
4K (4000K)
35K (3500K)
3K (3000K)
blank = 120/277
volt standard
F = fuse
mounting kits for pendant hung cylinders:
PK24 = 24” pendant
PK36 = 36” pendant
PK48 = 48” pendant
PK60 = 60” pendant
blank = matte white
B = matte black
Z = bronze
SA = satin aluminum
MA = glossy metallic aluminum
GAL = textured galvanite
6VLED = 6” apert. downlight reflector
SCL = soft specular
clear alzak
SWT = soft specular wheat
SST = soft specular straw
SPW = soft specular pewter
SBZ = soft specular bronze
HAZ = matte haze
see additional reflector finishes
on next page.
PF = standard with polished
self flange
C2SLED C2 = 8” aperture cylinder, 10”
diam. X 12.5” tall
8VLED = 8” apert. downlight reflector
C3SLED C3 = 8” aperture cylinder, 10”
diam. X 16” tall
*C65 cylinder available in
1100 lumens only.
R e c e s s e d D o w n l i g h t s E x a m p l e : 4 S Q L E D 110 0 4 K E M / 9 12 7 / 4 S Q L E D S C L P F - I C 4to access specification sheets online, enter keyword search at www.pathwaylighting.com, example 4SQLED.
C y l i n d e r s E x a m p l e : C 6 5 S L E D 110 0 4 K - B / 6 V L E D S C L P Fto access specification sheets online, enter keyword search at www.pathwaylighting.com, example C65SLED.
P e n d a n t E x a m p l e : P 2 M L D 2 4 K E 1 Cto access specification sheets online, enter keyword search at www.pathwaylighting.com, example P2MLD2.
How to Specify Pathway Lighting’s LED Luminaires
*6VLED available in two beam distributions, 42° spot (SP) and 58° medium (MD).
20151050 25 30
35
40
45
50
55
60
65
70
75
8085
90
942
1177
1413
1648
1884
2119
235
471
706
0
C2 & C3
p a t h w a y l i g h t i n g . c o m
SBLPFSoft Specular Black
MWHMatte White Finish
HAZPFHaze
EWTPFDiffused Wheat
ESTPFDiffused Straw
EPWPFDiffused Pewter
SWTPFSoft Specular Wheat
SSTPFSoft Specular Straw
SPWPFSoft Specular Pewter
CRGCorrugated Clear Alzak
SCLPFSoft Specular Clear
SBZPFSoft Specular Bronze
EBZPFDiffused Bronze
REFLECTOR f i n i s h e s
c o n t a c t u sPathway Lighting Products, Inc.P.O. Box 591, Old Saybrook, CT 06475-0591voice: 800.342.0592 or 860.388.6881fax: 800.207.0090 or 860.388.5766email: [email protected]
GLASS o p t i o n s
ESSEX DECO LUNA PARK AVENUE MIRIAM CYLINDER
Magner Sanborn Office, Spokane, Washington
ICSquare Aperture ICE
ICE Round Aperture ICE
Art Gallery, Pensacola, FloridaArchitect: Sam Marshall ArchitectsPhotography: Karena Cawthon
round and square aperture