Intro to Controller Area Networks (CAN) Part 2 of 2, E. Zivi, April 1, 2015 References: 1.A CAN...

23
Intro to Controller Area Networks (CAN) Part 2 of 2, E. Zivi, April 1, 2015 chip Application Note AN00228a entation Guide Analog Devices Application Note AN-1123 ersion 2.0 , Siemens Microelectronics, Inc., October 98 ut-can/the-can-protocol.html otocol-tutorial/ w.can-cia.org/index.php?id=systemdesign-can-physicallayer Requirements , TI SLLA270–January 2008 er-solutions.co.uk/download/Peak/CAN-Tutorial.pdf tions.com/english/about_canopen/about_canopen.shtml ANopen , by Pfeiffer, Ayre and Keydel s to Industrial Networks , by Farsi and Barbosa puter Networks, Alan Mislove, Northeastern University p:// electrosofts.com/can/index.html

Transcript of Intro to Controller Area Networks (CAN) Part 2 of 2, E. Zivi, April 1, 2015 References: 1.A CAN...

  • Slide 1
  • Intro to Controller Area Networks (CAN) Part 2 of 2, E. Zivi, April 1, 2015 References: 1.A CAN Physical Layer Discussion Microchip Application Note AN00228a 2.Controller Area Network (CAN) Implementation Guide Analog Devices Application Note AN-1123 3.Controller Area Network, CANPRES Version 2.0, Siemens Microelectronics, Inc., October 98 4.http://www.kvaser.com/en/about-can/the-can-protocol.htmlhttp://www.kvaser.com/en/about-can/the-can-protocol.html 5.http://www.kvaser.com/can-protocol-tutorial/http://www.kvaser.com/can-protocol-tutorial/ 6.CAN physical layer ref: http://www.can-cia.org/index.php?id=systemdesign-can-physicallayerhttp://www.can-cia.org/index.php?id=systemdesign-can-physicallayer 7.Controller Area Network Physical Layer Requirements, TI SLLA270January 2008 8.CAN Tutorial, http://www.computer-solutions.co.uk/download/Peak/CAN-Tutorial.pdfhttp://www.computer-solutions.co.uk/download/Peak/CAN-Tutorial.pdf 9.CANopen Introduction, ref: http://www.canopensolutions.com/english/about_canopen/about_canopen.shtmlhttp://www.canopensolutions.com/english/about_canopen/about_canopen.shtml 9.Embedded Networking with CAN and CANopen, by Pfeiffer, Ayre and Keydel 10.CAN open Implementation: Applications to Industrial Networks, by Farsi and Barbosa 11.CS4700/CS5700 Fundamentals of Computer Networks, Alan Mislove, Northeastern University 12.Controller Area Networks http://electrosofts.com/can/index.htmlhttp://electrosofts.com/can/index.html
  • Slide 2
  • Review: CAN is the Nervous System of Many Complex Systems New cars typically contain 50 to 100 microcontrollers
  • Slide 3
  • Review: CAN & International Standards Organization (ISO) Open Systems Interconnect (OSI) Reference Model 3 High level CAN Protocols implement Application layer and skip the four intervening layers
  • Slide 4
  • In Future Classes Well Introduce The CANopen Application 4 High level CAN Protocols implement Application layers and skip the four intervening layers ISO 11898 CAN Data Link Layer ISO 11898 CAN Physical Layer Application CiA 301 CANopen Application Layer & Communication Profile CiA 302 CANopen Framework for CANopen Managers & Programmable Devices CiA 4xx Device Profiles CiA 401 Generic I/O Profile CiA 402 Motion Control Profile IEC 61131-3 Programmable Devices Profile Not Implemented by CAN or CANopen
  • Slide 5
  • Review: CAN Differential Bus Interface Transceivers The CAN idle state presents a recessive state, signaled by a small differential voltage across CANH and CANL. With the indicated split termination, this idle voltage will be halfway between VDD (positive supply) and VSS (ground). The CAN dominant state occurs when one or more transceivers simultaneously close the indicated transistor switches driving CANH and CANL toward VDD and VSS, respectively. This open collector transistor switch configuration is referred to as a wired or since any node transmitting a dominant bit always overrides a recessive bit. Since a dominant bit represents a logic 0, this arrangement is sometimes referred to as wired and since bus a logic 1 state is achieved only if all nodes (node 1 AND node 2 AND node 3 ) signal logic 1 recessive bits). Micro- controller Transceiver Additional Transceivers Transistor Switches 60 Split Termination Example Capacitive coupling to ground 5
  • Slide 6
  • Review: CAN ISO11898 5V Nominal Bus Levels Assuming Split Termination Recessive voltage 2.5V 6
  • Slide 7
  • Example CAN Sample Signaling 7 Dominant bus state = logic 0 Recessive bus state = logic 1
  • Slide 8
  • Review: Wired OR Closing Node A switch OR closing Node B switch turns on the light. Conversely, the light is off unless Node A switch is open AND Node B switch is also open. 8
  • Slide 9
  • Review: CAN Arbitration Animation Mouse over graphic to control animated bus arbitration example 9
  • Slide 10
  • CAN Bit Synchronization, Timing & Propagation Delay 1.CAN signaling is bit synchronized across the entire network during the Sync portion which is the time required for each node to synchronize with the leading edge of a recessive to dominant edge transition. 2.The Signal Propagation is the time for the bit signal to propagate throughout the network. 3.Longer networks result in longer Signal Propagation delays which require longer bits resulting in slower data rates. 4.The Phase 1 portion delays sampling so that the bit signal can settle to a stable value Signal Propagation Propagation delay Settling time Sample Point 10 Faster bit rates require shorter propagation delays and therefore, smaller networks.
  • Slide 11
  • CAN Bit Rate Versus Bus Length 11 For a CAN bus, the signaling rate is determined from the total system delay down and back between the two most distant nodes of a system and the sum of the delays into and out of the nodes on a bus with the typical 5ns/m prop delay of a twisted-pair cable. A conservative rule of thumb for bus lengths over 100 m is: Signaling Rate (Mbps) Bus Length (m) 50 Bus Length (m) Signaling Rate (Kbps) 401,000 100500 200250 500100 100050
  • Slide 12
  • CAN Synchronization Via Bit Stuffing CAN nodes use Recessive to Dominant edges to maintain bit synchronization. Bit Stuffing ensures sufficient Recessive to Dominant edges to maintain bit synchronization A stuff Bit inserted after 5 consecutive bits at the same state A Stuff Bit is the inverse of previous bits and is discarded by the receiver
  • Slide 13
  • Slide 14
  • MicroMod TPDO 2 Transmit on Analog In Change of State Message (40 S / Division):
  • Slide 15
  • MicroMod Heartbeat, Note ACK bit transmitted by Receiving Node (40 S / Division):
  • Slide 16
  • TPDO 2 Analog Input Transited on change of state 4 Words, 2 Bytes each, little endian PCAN-Diag Hand Held Diagnostic Scope (40 S / Div.) 10-bit Analog Input Conversion Factor 5 V / 1023 counts = 0.0048876 V / count 0x023b 571 10 2.791 V 0x017a 378 10 1.847 V 0x0174 372 10 1.818 V 0x0169 361 10 1.764 V
  • Slide 17
  • MicroMod Heartbeat, with ACK bit (40 S / Div.) CANopen Heartbeat Messages 0: Boot-up 4: Stopped 5: Operational 127: Pre-operational Heartbeat 1 Byte Node Status
  • Slide 18
  • Five Types of CAN Error Checking 1.Bit error: Transmitting node compares transmitted & received bit value. 2.Stuff error: More than 5 successive recessive or dominant bits without a Stuff Bit. 3.CRC error: Sender CRC value in message does not match receiver CRC calculation. 4.Form error: Frame is not formatted properly. 5.Acknowledgement error: Transmitter sends recessive ACK bit. At least one receiver node must assert a dominant ACK reply into sender message.
  • Slide 19
  • The cyclic redundancy check (CRC) method is used for detection of bit errors. The binary polynomial used in CAN 2.0 is: gCAN (x) = x15 + x14 + x10 + x8 + x7 + x4 + x3 + 1 = 1100 0101 1001 10012 CAN Cyclic Redundancy Check Bit Bucket Error Frame is a superposition of 6 to 12 consecutive Bits asserted by nodes that detect an error. Note that Error Frame breaks bit stuffing rules
  • Slide 20
  • CAN Example Physical Network Layout 20
  • Slide 21
  • Typical Differential CAN Cabling Differential signaling minimizes common mode noise Twisting cables minimizes effects of electromagnetic interference Optional cable shielding protects against electrostatic interface 21
  • Slide 22
  • CAN Typical Physical Layer Connector CAN has a variety of connectors for various applications. The sub-D connector, shown above, is often used in laboratory setups. Only CAN_H and CAN_L are required, the other signals are optional. Note that CAN cables can distribute power to remote nodes. 22
  • Slide 23
  • Characteristic Impedance of CAN Twisted Cable Voltage charges capacitance, current charges inductance as wave travels down transmission line. Transmission line inductance & capacitance Equivalent Circuit