Magnum IEC Air Circuit Breakers Price ListAll Prices in US$ for Export Sale
Effective: May 2003
PL01301007E
Magnum IEC Air Circuit Breaker Product Family
The New Magnum Narrow Frame Drawout Breaker and Cassette
Magnum IEC Air Circuit BreakersPrice List (All prices in US$ for export sale)
Description Page
Description and Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Drawout Mounted Circuit Breakers – Up to 690 VacBasic Drawout Mounted Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . 3
Fixed Mounted Circuit Breakers – Up to 690 VacBasic Fixed Mounted Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Special Application – 1100 Vac Air Circuit BreakersBasic Drawout Mounted Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . 5Basic Fixed Mounted Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Fixed Mounting – Factory Fitted Terminal OptionsFixed Breaker Terminal Options (Factory Fitted) . . . . . . . . . . . . . . . . . . 5
Internal AccessoriesFactory Fitted Current Sensors and Rating Plugs . . . . . . . . . . . . . . . . . 6Trip Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Motor Operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Shunt Trip Attachment (STA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Spring Release Device (SRD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Undervoltage Release (UVR) or Second Shunt Trip Attachment (STA). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Auxiliary Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Bell Alarm/OTS Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Padlockable Pushbutton Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Operations Counter / Keylock Interlocking Provision . . . . . . . . . . . . . . 9Latch Check Switch/Metering Trip Unit Configuration . . . . . . . . . . . . . 9
Factory Fitted ACB Options – Breaker & Cassette Shipping Instructions
Fixed Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Drawout Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Drawout Cassette – Factory Fitted Cassette OptionsCassettes for Drawout Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . 11Cassette Arc Hood. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Cassette Door Escutcheon & Gasket Kit Option . . . . . . . . . . . . . . . . . . 11Cassette Shutters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Cassette Future Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Pre-wired Cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Cassette Shutter Field Option Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Cassette Cell Switch Field Option Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Cassette Cell Lock Provision Field Option Kit . . . . . . . . . . . . . . . . . . . . . 12
Description Page
Field Installable Option Kits for ACBsSecondary Contact Wiring Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Shunt Trip Attachment (STA) Field Option Kit . . . . . . . . . . . . . . . . . . . . . 13Spring Release Device (SRD) Field Option Kit . . . . . . . . . . . . . . . . . . . . 13Motor Operator Field Option Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Latch Check Switch Field Option Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Auxiliary Switch Field Option Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Undervoltage Release (UVR) Field Option Kit . . . . . . . . . . . . . . . . . . . . . 14Trip Indication Field Option Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Operation Counter Field Option Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Padlockable Pushbutton Cover Field Option Kit. . . . . . . . . . . . . . . . . . . 14Breaker Key Lock Provisions Field Option Kit . . . . . . . . . . . . . . . . . . . . 14
ACB Sensor Accessories & External Neutral Current SensorSensor/Rating Plug Field Change-out Kits . . . . . . . . . . . . . . . . . . . . . . . 15Neutral Current Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
External AccessoriesPrimary Terminal Adapter Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Mechanical Interlock Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Mechanical Interlock Assembly Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Rod or Cable Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Miscellaneous Accessories and Accessories for Breaker MaintenanceMiscellaneous Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Breaker Catalogue Number FormatSelection Ordering Form for Magnum IEC Breaker Product Family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Magnum IEC Cassettes for Draw-Out Circuit Breakers – Cassette Catalogue Number Format
Selection Ordering Form for Magnum IEC Breaker Product Family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Effective May 2003Prices subject to change without notice.Refer to SP 25-000X Dated March 1, 2002
Description and ApplicationCutler-Hammer Magnum Air Circuit Breakers are designed andengineered specifically for use in Metal Enclosed Switchgearassemblies applied at nominal voltages of 380/415, 440, and500/690 Vac. Ten continuous ratings – 800 through 6300 ampere,are covered by only two breaker sizes. A new Narrow Frame isalso available for even greater space savings through 2000A.
The breakers are 100% rated and are built and tested in an ISO9001 certified facility to applicable standards including EN60947-2.
Magnum air circuit breakers feature high interrupting and short-time ratings in small physical frame sizes. Interrupting ratings from40 kA to 100 kA are available.
The Magnum utilizes a true two-step stored energy mechanism formanually and electrically operated breakers. The potential energyis stored in the mechanism to close the breaker in 5 cycles or less.Sufficient energy to open the breaker remains available followingthe closing operation.
After closing, the charging spring can be recharged to providepotential energy for reclosing following a fault, providing highcontinuity of service. This feature allows for the followingsequence: charge-close-recharge-open-close-open.
On manually operated breakers, closing springs are charged byhand. For electrically operated breakers, springs are charged byan electric motor but can be manually charged if no power is available.
Power conductors are insulated and isolated in an engineeredcomposite resin frame that provides protection to personnel infront of the breaker. The levering-in device includes a safetyinterlock which prevents the door from being opened when thebreaker is in the closed position. The breaker cannot bewithdrawn when energized.
The advanced family of Digitrip RMS programmable trip unitswere designed exclusively for Magnum. It uses provenmicroprocessor trip unit technology to provide expandedprotection and information capabilities.
True RMS sensing trip units provide accurate coordination withthe conductors and equipment the breaker is designed to protect.Basic protection is offered in the Digitrip RMS 220, 520, 520M and520MC. Advanced protection is offered in the Digitrip RMS 1150which can be programmed at the faceplate or with a PC.
The Digitrip RMS 220 provides long time and instantaneousprotection only.
The Digitrip RMS 520 enables the user as many as nine phase andearth current protection settings for maximum flexibility in trip-curve shaping and multi-unit coordination, and adds earth currentprotection settings.
The Digitrip RMS 520M adds phase, neutral, and earth currentmetering in a four character LCD display window.
The Digitrip RMS 520MC includes all of the capabilities of the520M trip unit as well as communications capability.
The Digitrip RMS 1150 provides programmability for moresophisticated distribution systems. It incorporates systemsmonitoring information including power factor, voltage, current,harmonic distortion values, and waveform capture with a threeline (eight character) LED display. In addition, this trip unit has twoprogrammable contacts, time stamping of trip events, 1%accuracy on metered values and 2% on energy and power,systems diagnostics and IMPACC/PowerNet communications.
A common family of accessories are available to fit all breakerframe sizes. Magnum through-the-window accessories areinstalled near the right front of the breaker. The unique windows inthe breaker cover enable accessories to be quickly identified byname and rating. These accessories are plug-in, providing foreasy mounting and wiring to save both installation time and cost.Spring release, shunt trip and undervoltage release are offered asfactory installed options or they can be easily mounted in the fieldby user personnel. Internal accessories include auxiliary switches(up to 6 NO and 6 NC contacts), overcurrent trip switch (Bellalarm) and an electrical operator can also be mounted at thefactory or in the field.
Pricing InstructionsThis price list is to be used exclusively for pricing low voltagebreakers and accessories for use by a low voltage panelassembler in the completion of a total switchgear assembly.
All quotations from this price list will be per SP 25-000X datedMarch 1, 2002.
Price ListPage 2 Effective: May 2003
Magnum IEC Air Circuit Breakers
Magnum IEC Air Circuit Breakers have common heights and depths to facilitate
standardized designs in low voltage panel systems.
Price ListEffective: May 2003 Page 3
Magnum IEC Air Circuit Breakers
PL01301007E
(1) Magnum ACBs are 100% Thermal Rated (no de-rating necessary when properly applied in a specified enclosure).(2) Interrupting Ratings shown are also applicable at 380V / 415V / 440V / 500V / 690V unless otherwise indicated.(3) Phasing Left to Right when facing front of breaker. Neutral is rated 100% of continuous current.(4) Icu is 100kA at 440Vac and 85kA at 690 Vac. Ics is 85kA at 690 Vac and below.(5) Magnum ACBs carry an IT rating at 440 Vac per EN 60947-2 Annex H. Contact Cutler-Hammer for 690 Vac IT applications.
Drawout Mounted Circuit Breakers – Up to 690 VacBasic Drawout Mounted Circuit Breaker Tested to EN 60947-2 Cat B; witnessed and certified with a KEMA-KEUR Mark.
List prices for Basic Drawout Mounted Air Circuit Breakers include: Manually operated breaker frame (moving portion) only with primarydisconnecting contacts (finger clusters) and one current sensor per phase.
Breaker list prices do not include a trip unit, accessories, or cassette. Each must be priced separately.
3-Pole Air Circuit Breakers 4-Pole Air Circuit Breakers
ContinuousCurrent Rating
Amps at 40°C (1)
Magnum ACBFrame Type
InterruptingRatings (kA)Icu/Ics (2)
Icw WithstandRating (kA) 1-Sec/3-Sec
Catalogue NumbersPhasing (3)
(Left to Right)List Price in
US$Catalogue Numbers
Phasing (3)(Left to Right)
List Price inUS$
Narrow Frame Drawout ACB (5)
80010001250
8001000125016002000
8001000125016002000
NarrowNarrowNarrow
NarrowNarrowNarrowNarrowNarrow
NarrowNarrowNarrowNarrowNarrow
40/4040/4040/40
50/5050/5050/5050/5050/50
65/6565/6565/6565/6565/65
40/--40/--40/--
50/--50/--50/--50/--50/30
65/4065/4065/4065/4065/40
MWN4083LEAMWN4103LEAMWN4123LEA
MWN5083LEAMWN5103LEAMWN5123LEAMWN5163LEAMWN5203LEA
MWN6083LEAMWN6103LEAMWN6123LEAMWN6163LEAMWN6203LEA
ABCABCABC
ABCABCABCABCABC
ABCABCABCABCABC
$2,450 $2,550 $2,900
$2,550 $2,700 $3,050 $4,500 $5,600
$2,650 $2,750 $2,950 $4,850 $5,850
MWN4084LEAMWN4104LEAMWN4124LEA
MWN5084LEAMWN5104LEAMWN5124LEAMWN5164LEAMWN5204LEA
MWN6084LEAMWN6104LEAMWN6124LEAMWN6164LEAMWN6204LEA
NABCNABCNABC
NABCNABCNABCNABCNABC
NABCNABCNABCNABCNABC
$3,275 $3,450 $3,650
$3,550 $3,875 $4,275 $6,100 $7,300
$4,025 $4,300 $4,550 $6,175 $7,350
Double Frame Drawout ACB (5)
4000
400050006300
400050006300
Double
DoubleDoubleDouble
DoubleDoubleDouble
65/65
85/8585/8585/85
100/100100/100100/100
65/--
85/--85/--85/--
100/--100/--100/--
MWI64N3LEA
MWI84N3LEAMWI85N3LEAMWI86N3LEA
MWIC4N3LEAMWIC5N3LEAMWIC6N3LEA
AABBCC
AABBCCAABBCCAABBCC
AABBCCAABBCCAABBCC
$12,350
$12,900 $22,250 $28,460
$14,700 $24,250 $30,460
MWI64N4LEA
MWI84N4LEAMWI85N4LEAMWI86N4LEA
MWIC4N4LEAMWIC5N4LEAMWIC6N4LEA
NNAABBCC
NNAABBCCNNAABBCCNNAABBCC
NNAABBCCNNAABBCCNNAABBCC
$16,300
$17,800 $30,010 $38,288
$20,010 $31,900 $40,800
Standard Frame Drawout ACB (5)
800100012501600200025003200
800100012501600200025003200
800100012501600200025003200
StandardStandardStandardStandardStandardStandardStandard
StandardStandardStandardStandardStandardStandardStandard
StandardStandardStandardStandardStandardStandardStandard
65/6565/6565/6565/6565/6565/6565/65
85/8585/8585/8585/8585/8585/8585/85
100/85 (4)100/85 (4)100/85 (4)100/85 (4)100/85 (4)100/85 (4)100/85 (4)
65/--65/--65/--65/--65/5065/5065/50
85/6585/6585/6585/6585/6585/6585/65
85/6585/6585/6585/6585/6585/6585/65
MWI6083LEAMWI6103LEAMWI6123LEAMWI6163LEAMWI6203LEAMWI6253LEAMWI6323LEA
MWI8083LEAMWI8103LEAMWI8123LEAMWI8163LEAMWI8203LEAMWI8253LEAMWI8323LEA
MWIC083LEAMWIC103LEAMWIC123LEAMWIC163LEAMWIC203LEAMWIC253LEAMWIC323LEA
ABCABCABCABCABCABCABC
ABCABCABCABCABCABCABC
ABCABCABCABCABCABCABC
$2,800 $2,900 $3,100 $4,960 $6,000 $7,350 $8,400
$3,125 $3,375 $3,825 $5,075 $6,300 $7,950 $9,375
$3,500 $3,725 $4,225 $5,475 $6,575 $8,775 $9,975
MWI6084LEAMWI6104LEAMWI6124LEAMWI6164LEAMWI6204LEAMWI6254LEAMWI6324LEA
MWI8084LEAMWI8104LEAMWI8124LEAMWI8164LEAMWI8204LEAMWI8254LEAMWI8324LEA
MWIC084LEAMWIC104LEAMWIC124LEAMWIC164LEAMWIC204LEAMWIC254LEAMWIC324LEA
NABCNABCNABCNABCNABCNABCNABC
NABCNABCNABCNABCNABCNABCNABC
NABCNABCNABCNABCNABCNABCNABC
$4,200 $4,475 $4,725 $6,325 $7,475 $9,775 $11,400
$4,425 $4,700 $4,975 $6,625 $8,400 $10,400 $12,875
$4,875 $5,150 $5,400 $6,875 $8,775 $11,150 $12,950
Price ListPage 4 Effective: May 2003
Magnum IEC Air Circuit Breakers
3-Pole Air Circuit Breakers 4-Pole Air Circuit Breakers
ContinuousCurrent Rating
Amps at 40°C (1)
Magnum ACBFrame Type
InterruptingRatings (kA)Icu/Ics (2)
Icw WithstandRating (kA) 1-Sec/3-Sec
Catalogue Numbers(3)
Phasing (4)(Left to Right)
List Price inUS$
Catalogue Numbers(3)
Phasing (4)(Left to Right)
List Price inUS$
Narrow Frame Fixed ACB (6)
80010001250
8001000125016002000
8001000125016002000
NarrowNarrowNarrow
NarrowNarrowNarrowNarrowNarrow
NarrowNarrowNarrowNarrowNarrow
40/4040/4040/40
50/5050/5050/5050/5050/50
65/6565/6565/6565/6565/65
40/--40/--40/--
50/--50/--50/--50/--50/30
65/4065/4065/4065/4065/40
MWN4083HEAMWN4103HEAMWN4123HEA
MWN5083HEAMWN5103HEAMWN5123HEAMWN5163HEAMWN5203HEA
MWN6083HEAMWN6103HEAMWN6123HEAMWN6163HEAMWN6203HEA
ABCABCABC
ABCABCABCABCABC
ABCABCABCABCABC
$2,075 $2,195 $2,370
$2,225 $2,325 $2,525 $3,875 $4,925
$2,325 $2,425 $2,825 $4,375 $5,325
MWN4084HEAMWN4104HEAMWN4124HEA
MWN5084HEAMWN5104HEAMWN5124HEAMWN5164HEAMWN5204HEA
MWN6084HEAMWN6104HEAMWN6124HEAMWN6164HEAMWN6204HEA
NABCNABCNABC
NABCNABCNABCNABCNABC
NABCNABCNABCNABCNABC
$3,075 $3,250 $3,450
$3,200 $3,400 $3,725 $5,525 $6,625
$3,625 $3,975 $4,450 $5,725 $6,750
Double Frame Fixed ACB (6)
4000
400050006300
400050006300
Double
DoubleDoubleDouble
DoubleDoubleDouble
65/65
85/8585/8585/85
100/100100/100100/100
65/--
85/--85/--85/--
100/--100/--100/--
MWI64N3HEA
MWI84N3HEAMWI85N3HEAMWI86N3HEA
MWIC4N3HEAMWIC5N3HEAMWIC6N3HEA
AABBCC
AABBCCAABBCCAABBCC
AABBCCAABBCCAABBCC
$11,100
$11,750 $18,700 $24,100
$13,075 $19,700 $25,900
MWI64N4HEA
MWI84N4HEAMWI85N4HEAMWI86N4HEA
MWIC4N4HEAMWIC5N4HEAMWIC6N4HEA
NNAABBCC
NNAABBCCNNAABBCCNNAABBCC
NNAABBCCNNAABBCCNNAABBCC
$14,070
$15,200 $26,150 $34,150
$16,200 $27,600 $36,100
Standard Frame Fixed ACB (6)
800100012501600200025003200
800100012501600200025003200
800100012501600200025003200
StandardStandardStandardStandardStandardStandardStandard
StandardStandardStandardStandardStandardStandardStandard
StandardStandardStandardStandardStandardStandardStandard
65/6565/6565/6565/6565/6565/6565/65
85/8585/8585/8585/8585/8585/8585/85
100/85 (5)100/85 (5)100/85 (5)100/85 (5)100/85 (5)100/85 (5)100/85 (5)
65/--65/--65/--65/--65/5065/5065/50
85/6585/6585/6585/6585/6585/6585/65
85/6585/6585/6585/6585/6585/6585/65
MWI6083HEAMWI6103HEAMWI6123HEAMWI6163HEAMWI6203HEAMWI6253HEAMWI6323HEA
MWI8083HEAMWI8103HEAMWI8123HEAMWI8163HEAMWI8203HEAMWI8253HEAMWI8323HEA
MWIC083HEAMWIC103HEAMWIC123HEAMWIC163HEAMWIC203HEAMWIC253HEAMWIC323HEA
ABCABCABCABCABCABCABC
ABCABCABCABCABCABCABC
ABCABCABCABCABCABCABC
$2,325 $2,425 $2,875 $4,525 $5,400 $7,150 $8,050
$2,725 $2,975 $3,387 $4,440 $5,625 $7,425 $8,725
$2,925 $3,245 $3,700 $4,975 $6,100 $8,375 $9,575
MWI6084HEAMWI6104HEAMWI6124HEAMWI6164HEAMWI6204HEAMWI6254HEAMWI6324HEA
MWI8084HEAMWI8104HEAMWI8124HEAMWI8164HEAMWI8204HEAMWI8254HEAMWI8324HEA
MWIC084HEAMWIC104HEAMWIC124HEAMWIC164HEAMWIC204HEAMWIC254HEAMWIC324HEA
NABCNABCNABCNABCNABCNABCNABC
NABCNABCNABCNABCNABCNABCNABC
NABCNABCNABCNABCNABCNABCNABC
$4,042 $4,075 $4,625 $5,900 $6,800 $9,500 $10,825
$4,150 $4,500 $4,850 $6,250 $7,875 $10,100 $12,275
$4,075 $4,375 $4,675 $6,350 $8,230 $10,750 $12,550
(1) Magnum ACBs are 100% Thermal Rated (no de-rating necessary when properly applied in a specified enclosure).(2) Interrupting Ratings shown are also applicable at 380V / 415V / 440V / 500V / 690V unless otherwise indicated.(3) Fixed breakers have (H) horizontal terminals. Vertical adapters (V) are priced separately. (4) Phasing Left to Right when facing front of breaker. Neutral is rated 100% of continuous current.(5) Icu is 100kA at 440Vac and 85kA at 690 Vac. Ics is 85kA at 690 Vac and below.(6) Magnum ACBs carry an IT rating at 440 Vac per EN 60947-2 Annex H. Contact Cutler-Hammer for 690 Vac IT applications.
Fixed Mounted Circuit Breakers – Up to 690 VacBasic Fixed Mounted Circuit Breaker Tested to EN 60947-2 Cat B; witnessed and certified with a KEMA-KEUR Mark.
List prices for Basic Fixed Mounted Air Circuit Breakers include: Manually operated breaker frame only with horizontal rear terminals, onecurrent sensor per phase, and one secondary terminal block mounting bracket.
Breaker list prices do not include a trip unit or accessories, which are priced separately.
Price ListEffective: May 2003 Page 5
Magnum IEC Air Circuit Breakers
Special Application – 1100 Vac Air Circuit Breakers – Drawout & Fixed MountingBasic Drawout Mounted Circuit BreakerTested to EN 60947-2 Cat B; witnessed and certified with a KEMA-KEUR Mark.
List prices for Basic Drawout Mounted Air Circuit Breakers include: Manually operated breaker frame (moving portion) only with primarydisconnecting contacts (finger clusters) and one current sensor per phase.
Breaker list prices do not include a trip unit, accessories, or cassette. Each must be priced separately.
3-Pole Air Circuit Breakers 4-Pole Air Circuit Breakers
ContinuousCurrent Rating
Amps at 40°C (1)
Magnum ACBFrame Type
InterruptingRatings (kA) at1100V Icu/Ics
Icw WithstandRating (kA) 1-Sec/3-Sec
Catalogue NumbersPhasing (3)
(Left to Right)List Price in
US$Catalogue Numbers
Phasing (3)(Left to Right)
List Price inUS$
3200 Standard 25/25 ---- / ---- MWK2323LEA ABC $9,375 MWK2324LEA NABC $12,875
Basic Fixed Mounted Circuit BreakerTested to EN 60947-2 Cat B; witnessed and certified with a KEMA-KEUR Mark.
List prices for Basic Fixed Mounted Air Circuit Breakers include: Manually operated breaker frame only with horizontal rear terminals, onecurrent sensor per phase, and one secondary terminal block mounting bracket.
Breaker list prices do not include a trip unit or accessories, which are priced separately.
3-Pole Air Circuit Breakers 4-Pole Air Circuit Breakers
ContinuousCurrent Rating
Amps at 40°C (1)
Magnum ACBFrame Type
InterruptingRatings (kA) at1100V Icu/Ics
Icw WithstandRating (kA) 1-Sec/3-Sec
Catalogue NumbersPhasing (3)
(Left to Right)List Price in
US$Catalogue Numbers
Phasing (3)(Left to Right)
List Price inUS$
3200 Standard 25/25 ---- / ---- MWK2323HEA ABC $8,725 MWK2324HEA NABC $12,275
(1) Magnum ACBs are 100% Thermal Rated (no de-rating necessary when properly applied in a specified enclosure).(2) Fixed breakers have (H) horizontal terminals. Vertical adapters (V) are priced separately. (3) Phasing Left to Right when facing front of breaker. Neutral is rated 100% of continuous current.
Fixed Mounting – Factory Fitted Terminal OptionsFixed Breaker Terminal Options (Factory Fitted)Horizontal Terminals (H) are provided as standard on all fixed Magnum breakers.
Factory Fitted Vertical Adapters (V) are available on breaker upper and lower terminals.
Vertical Adapters and Front Connectors are also available in kit form. Refer to Field Installable Terminal Kits.
Catalogue Number Position 8
Factory FittedTerminal Description Breaker Terminals
Magnum FixedBreaker Frame
PolesContinuous
Current Rating (A)Short CircuitRating (kA)
List Price in US$
H
VVVVVV
VVVVVV
Horizontal Terminals
Vertical Adapters Vertical Adapters Vertical Adapters Vertical Adapters Vertical Adapters Vertical Adapters
Vertical Adapters Vertical Adapters Vertical Adapters Vertical Adapters Vertical Adapters Vertical Adapters
Upper and Lower Terminals
Upper and Lower TerminalsUpper and Lower TerminalsUpper and Lower TerminalsUpper and Lower TerminalsUpper and Lower TerminalsUpper and Lower Terminals
Upper and Lower TerminalsUpper and Lower TerminalsUpper and Lower TerminalsUpper and Lower TerminalsUpper and Lower TerminalsUpper and Lower Terminals
All Frames
NarrowStandardStandardStandardDoubleDouble
NarrowStandardStandardStandardDoubleDouble
3 or 4 Pole
333333
444444
All Ratings
800 - 2000 A800 - 1600 A800 - 2000 A2500 - 3200 A
4000 A5000 - 6300 A
800 - 2000 A800 - 1600 A800 - 2000 A2500 - 3200 A
4000 A5000 - 6300 A
All Ratings
65 kA65 kA100 kA100 kA100 kA100 kA
65 kA65 kA100 kA100 kA100 kA100 kA
$0
$285$285$375$475$750$950
$380$380$500$575
$1,000$1,150
Price ListPage 6 Effective: May 2003
Magnum IEC Air Circuit Breakers
Internal AccessoriesFactory Fitted Current Sensors and Rating PlugsBasic Breaker List Price includes one rating plug and one sensor per pole.
Select the Current Sensor and Rating Plug rating by ACB Frame.
Select NN if ACB is Non-Automatic (Switch Disconnector).
For 3 pole breaker earth fault applications on 3 phase, 4 wire circuits, external neutral mounted sensors must be ordered separately.
Magnum Narrow FrameAvailable Sensors & Rating Plugs
Catalogue NumberPosition 11,12Factory Fitted
2000 A 1600 A 1250 A 1000 A 800 A
NN - None201613121008070604030502
20001600125012001000800630600400300250200
1600125012001000800630600400300250200
125012001000800630600400300250200
1000800630600400300250200
800630600400300250200
Magnum Standard FrameAvailable Sensors & Rating Plugs
Catalogue NumberPosition 11,12Factory Fitted
3200 A 2500 2000 A 1600 A 1250 A 1000 A 800 A
NN - None3225201613121008070604030502
3200250020001600125012001000800630600400300250200
250020001600125012001000800630600400300250200
20001600125012001000800630600400300250200
1600125012001000800630600400300250200
125012001000800630600400300250200
1000800630600400300250200
800630600400300250200
Magnum Double FrameAvailable Sensors & Rating Plugs
Catalogue NumberPosition 11,12Factory Fitted
6300 A 5000 A 4000 A
NN - None635040322520
6300500040003200
5000400032002500
4000320025002000
Price ListEffective: May 2003 Page 7
Magnum IEC Air Circuit Breakers
Internal Accessories – Factory Fitted Trip UnitsTrip Unit - Add to Basic Breaker List PriceFactory fitted option for fixed or drawout breakers.
Basic Breaker List Price does not include trip unit.
Catalogue NumberPosition 13, 14Factory Fitted
Digitrip RMS TripUnit (1)
FunctionsTrip Unit PowerRelay Module
Supply Voltage (2)
Power RelayModule Alarm or
Trip Contact
Trip Unit Availabilityon Magnum Frame(s)
List Price in US$
NNNNNNNN
22
525W
M2MW
MTMUMVMJMKMLMEMCMF
CTCUCVCJCKCLCECCCF
1W1N1P1R1S1T
Non-Automatic (5)Non-Automatic
Non-Automatic (5)Non-Automatic
220
520520i
520M520Mi
520M520M520M520Mi520Mi520Mi520Mi520Mi520Mi
520MC520MC520MC520MCi520MCi520MCi520MCi520MCi520MCi
1150i1150i1150i1150i1150i1150i
3-Pole ACB3-Pole ACB4-Pole ACB4-Pole ACB
LI
LSI LSIG
LSILSIG
LSILSILSI
LSIGLSIGLSIGLSIALSIALSIA
LSILSILSI
LSIGLSIGLSIGLSIALSIALSIA
LSILSILSI
LSIG & LSIALSIG & LSIALSIG & LSIA
Not ApplicableNot ApplicableNot ApplicableNot Applicable
Not Applicable
Not ApplicableNot Applicable
None (3)None (3)
24/48 Vdc120 Vac240 Vac
24/48 Vdc120 Vac240 Vac
24/48 Vdc120 Vac240 Vac
24/48 Vdc120 Vac240 Vac
24/48 Vdc120 Vac240 Vac
24/48 Vdc120 Vac240 Vac
24/48 Vdc120 Vac240 Vac
24/48 Vdc120 Vac240 Vac
NoneNoneNoneNone
None
NoneNone
NoneNone
High Load AlarmHigh Load AlarmHigh Load Alarm
Ground TripGround TripGround Trip
Ground AlarmGround AlarmGround Alarm
High Load AlarmHigh Load AlarmHigh Load Alarm
Ground TripGround TripGround Trip
Ground AlarmGround AlarmGround Alarm
(4) Programmable(4) Programmable(4) Programmable(4) Programmable(4) Programmable(4) Programmable
Narrow/StandardDouble
Narrow/StandardDouble
Narrow/Standard
All FramesAll Frames
All FramesAll Frames
All FramesAll FramesAll FramesAll FramesAll FramesAll FramesAll FramesAll FramesAll Frames
All FramesAll FramesAll FramesAll FramesAll FramesAll FramesAll FramesAll FramesAll Frames
Standard/DoubleStandard/DoubleStandard/DoubleStandard/DoubleStandard/DoubleStandard/Double
DEDUCT $150DEDUCT $300DEDUCT $180DEDUCT $400
$735
$1,057$1,421
$1,339$1,702
$1,444$1,444$1,444$1,809$1,809$1,809$1,809$1,809$1,809
$1,689$1,689$1,689$2,052$2,052$2,052$2,052$2,052$2,052
$3,744$3,744$3,744$4,253$4,253$4,253
(1) Digitrip 520MC Trip Unit requires Pow-R-Net Software version 3.2 or higher if Pow-R-Net is used.(2) Power Relay Module mounted integral to ACB receives power from an external customer supplied source wired through the breaker secondary contacts.
The external source powers the trip unit digital display (520M, 520MC, & 1150), communications functions (520MC and 1150), and relays.(3) No Power Relay Module provided for the 520M trip unit when this catalogue code is selected. The Digital display powered from current sensors
and the ACB must carry 20% rated sensor current to power digital display. (4) Digitrip 1150 has programmable relay trip or alarm contacts for trip unit protective and high load functions. (5) The maximum available instantaneous interrupting rating for the Magnum Standard Frame Non-Automatic Air Circuit Breaker is 85kA when the breaker is used
with a suitable external overcurrent protective device with instantaneous protection.
Digitrip 220 Trip Unit Digitrip 520i Trip Unit Digitrip 520Mi Trip Unit Digitrip 520MCi Trip Unit Digitrip 1150i Trip Unit
Price ListPage 8 Effective: May 2003
Magnum IEC Air Circuit Breakers
Catalogue NumberPosition 15
Factory Fitted
Voltage (AC:50/60 Hz)
List Price in US$
NARCH
None110 - 127 Vac/dc208 - 250 Vac/dc
24Vdc48Vdc
$0 $196 $196 $196 $196
Spring Release Device (SRD)Factory fitted option for fixed or drawout breakers.
Catalogue NumberPosition 17
Factory Fitted
Voltage (AC:50/60 Hz)
List Price in US$
NARCH
None110 - 127 Vac/dc208 - 250 Vac/dc
24Vdc48Vdc
$0 $196 $196 $196 $196
Internal Accessories – Factory Fitted ACB OptionsShunt Trip Attachment (STA)Factory fitted option for fixed or drawout breakers.
Refer applications requiring capacitor trip devices to C-H.
Motor OperatorFactory fitted option for fixed or drawout breakers.
For Electrically Operated breakers, price and select a Motor Operator, and Spring Release Device and (if required) a Shunt Trip Attachment (STA).
Catalogue NumberPosition 16
Factory Fitted
Voltage (AC:50/60 Hz)
List Price in US$
MNPLKWT
Manual Operated110 - 125 Vac220 - 250 Vac
24 Vdc48 Vdc
110 - 125 Vdc220 - 250 Vdc
$0 $960 $960 $960 $960 $960 $960
Undervoltage Release (UVR) or Second Shunt Trip Attachment (STA)Factory fitted option for fixed or drawout breakers.
Catalogue NumberPosition 18 Factory
Fitted
Voltage (AC:50/60 Hz)
UVR Release Type(1) (2) (3) (4)
List Price in US$
NARC HEFGXJK1234
None110/127Vac208/240Vac
24Vdc48Vdc
110/125Vdc220/250Vdc
32Vdc380/415Vac
480Vac600Vac
110/127Vac208/250Vac
24Vdc48Vdc
NoneInstantaneousInstantaneousInstantaneousInstantaneousInstantaneousInstantaneousInstantaneousInstantaneousInstantaneousInstantaneous
Second Shunt TripSecond Shunt TripSecond Shunt TripSecond Shunt Trip
$0 $340 $340 $340 $340 $340 $340 $340 $340 $340 $340 $196 $196 $196 $196
(1) Refer requests for Time Delay UVRs to C-H.(2) Digitrip 1150 Trip Units have an integral adjustable time delay Undervoltage trip function from the line voltage. (3) An external customer supplied panel mounted Time Delay Undervoltage Relay can also be applied, wired through the breaker
secondary contacts to a Shunt Trip Attachment for Time Delay Undervoltage protection. (4) Each second Shunt Trip Attachment includes its own cut-off switch.
Price ListEffective: May 2003 Page 9
Magnum IEC Air Circuit Breakers
Catalogue NumberPosition 19 Factory Fitted
Contact Type List Price in US$ Comments
N246
None2a/2b4a/4b6a/6b
$0 $80 $160 $240
(1) 4a/4b Maximum contacts on Narrow Frame(2) 6a/6b Maximum on Double or Standard Frames
(1) Refer applications requiring 6a/6b contacts on the Narrow Frame Breaker to Cutler-Hammer.(2) Except when a second Shunt Trip Attachment is selected, which occupies a 2a/2b contact mounting position.
Bell Alarm/OTS SwitchFactory fitted option for fixed or drawout breakers.
For breakers with trip units only, not available on non-automatic breakers.
Catalogue NumberPosition 20
Factory Fitted
Mechanical TripIndicator
OTS Switch With 2Form C Contacts
List Price in US$
ENY
NoYesYes
NoNoYes
$0 $75 $118
Padlockable Pushbutton CoversFactory fitted option for fixed or drawout breakers.
Catalogue NumberPosition 21 Factory
FittedDescription List Price in US$
NMPC H
NoneMetal Frame (Open and Close)Plastic Frame (Open and Close)
Block Close PB Metal FrameBlock Close PB Plastic Frame
$0 $144 $144 $144 $144
Internal Accessories – Factory Fitted ACB OptionsAuxiliary SwitchFactory fitted option for fixed or drawout breakers.
Operations Counter / Keylock Interlocking ProvisionFactory fitted option for fixed or drawout breakers.
Catalogue NumberPosition 22
Factory FittedCounter Type Keylock Provision List Price in US$
NKCRAYLH
No CounterNo CounterNo CounterNo Counter
Operations Ctr Operations Ctr Operations Ctr Operations Ctr
No LockKirk lock
Castell LockRonis lockNo LockKirk lock
Castell LockRonis Lock
$0 $72 $72 $72 $133 $206 $206 $206
Latch Check Switch/Metering Trip Unit ConfigurationFactory fitted option for fixed or drawout breakers.
Catalogue NumberPosition 23
Factory FittedLatch Check Switch (LCS) Connection
Metering Trip Unit Voltage Connection (Applicable only when Digitrip RMS 1150 Trip Unit is selected)
List Price in US$
NMLYCD
NoneNone
Latch Check Switch Wired to Spring ReleaseSpring Release Latch Check Switch
(1) Latch Check Switch for External Wiring(1) Latch Check Switch for External Wiring
Upper Terminal Voltage ConnectionLower Terminal Voltage ConnectionUpper Terminal Voltage ConnectionLower Terminal Voltage ConnectionUpper Terminal Voltage ConnectionLower Terminal Voltage Connection
$0 $0
$110 $110 $110 $110
(1) Key interlock provision Includes a hole in the front cover with cap plus provisions hardware kit forcustomer installation of customer supplied cylinder lock.
(1) Form C contact wired through breaker secondary contacts for external customer use.
Price ListPage 10 Effective: May 2003
Magnum IEC Air Circuit Breakers
Factory Fitted ACB Options – Breaker & Cassette Shipping InstructionsFixed BreakersFor fixed circuit breakers, catalog position 24 is to specify the factory shipping instructions.
Breaker Catalogue NumberPosition 24
Factory InstalledShipment Description
Magnum ACB Frame Type
Door Escutcheon &Gasket Kit
AF
Fixed Breaker AloneFixed Breaker Alone
All FramesAll Frames
IncludedNot Included
Drawout BreakersMagnum Double Frame breakers are always shipped separately from the cassette.
For Drawout Circuit Breakers, catalog position 24 is only to specify the drawout breaker and cassette shipping instructions.
Cassettes and cassette options are not included in the Basic Breaker List Price and are priced separately.
Configure and price the cassette and cassette options using the cassette catalog number system.
Breaker Catalogue NumberPosition 24
Factory InstalledShipment Description
Magnum ACB Frame Type
ShuttersPre-Wired Cassette
Secondary Terminal Blocks
A
CC
PP
SS
WW
Drawout Breaker Alone
Drawout ACB in CassetteDrawout ACB in Cassette
Drawout ACB in CassetteDrawout ACB in Cassette
Drawout ACB in CassetteDrawout ACB in Cassette
Drawout ACB in CassetteDrawout ACB in Cassette
All Frames
NarrowStandard
NarrowStandard
NarrowStandard
NarrowStandard
Not Applicable
No ShuttersNo Shutters
No ShuttersNo Shutters
ShuttersShutters
ShuttersShutters
Not Applicable
NoNo
Pre-WiredPre-Wired
NoNo
Pre-WiredPre-Wired
Future Use by Cutler-HammerFuture factory option for fixed or drawout breakers.
Catalogue NumberPosition 25
(Future Option)Description List Price in US$
X Future use by Cutler-Hammer $0
Price ListEffective: May 2003 Page 11
Magnum IEC Air Circuit Breakers
Drawout Cassette – Factory Fitted Cassette OptionsCassettes for Drawout Circuit Breakers Cassette standard features include arc hood, provisions for secondary terminal blocks & wiring, a cell rejection kit.
Cassettes may be shipped with breaker by specifying breaker Catalogue position 24.
Cassette CatalogueNumber Positions 1 - 6
Magnum ACB Frame Type
PolesContinuous CurrentRating (A) at 40°C
List Price in US$
NN203HEN203HEN323HEN403HEN503H
NN204HEN204HEN324HEN404HEN504H
NarrowStandardStandardDoubleDouble
NarrowStandardStandardDoubleDouble
3 Pole3 Pole3 Pole3 Pole3 Pole
4 Pole4 Pole4 Pole4 Pole4 Pole
800-2000800-20002500-3200
40005000 - 6300
800-2000800-20002500-3200
40005000 - 6300
$847 $1,060 $1,590 $2,120 $3,180
$1,076 $1,350 $2,010 $2,700 $4,020
Cassette Arc HoodFactory fitted option for fixed or drawout breakers.
Cassette CatalogueNumber Position 7
Description List Price in US$
AK
600 Vac Breakers1100 Vac Breakers
$0 $250
Cassette Door Escutcheon & Gasket Kit OptionFactory fitted option for fixed or drawout breakers.
Cassette CatalogueNumber Positions 8 & 9
Door Escutcheon &Gasket Kit
List Price in US$
DNXN
IncludedNot Included
$0 Deduct $20
Cassette Future OptionFuture Factory Fitted option.
Cassette Catalogue Number Positions 11 - 13
Cassette Type List Price in US$
NNN All Cassettes $0
Cassette ShuttersFactory Fitted cassette shutters.
Shutters are also available as a field installable kit for customer installation.
Cassette CatalogueNumber Position 10
DescriptionMagnum ACB
Frame TypePoles Continuous Current
Rating (A) at 40°C List Price in US$
N
SSS
SSS
No Shutters
Shutters InstalledShutters InstalledShutters Installed
Shutters InstalledShutters InstalledShutters Installed
All Frames
NarrowStandardDouble
NarrowStandardDouble
3 and 4 Pole
3 Pole3 Pole3 Pole
4 Pole4 Pole4 Pole
All Ratings
800 to 2000800 to 32004000 to 6300
800 to 2000800 to 32004000 to 6300
$0
$140 $150 $295
$170 $195 $340
Narrow Frame Cassette - Rear View
Narrow Frame Cassette - Front View
Price ListPage 12 Effective: May 2003
Magnum IEC Air Circuit Breakers
Drawout Cassette – Factory Fitted Cassette OptionsPre-wired Cassettes Prices shown are adders for factory pre-wired cassettes.
Pre-wired cassettes Include wiring and terminal blocks mounted and wired to secondary contacts ready to receive ACB.
Cassette Catalogue Number Positions 14 - 15
Wiring DescriptionMagnum Breaker
FrameContinuous Rating (A) List Price in US$
NC
WCWCWC
Un-Wired
Pre-Wired for ACBPre-Wired for ACBPre-Wired for ACB
All
NarrowStandardDouble
All
800-2000800-3200
4000-6300
$0
$250$300$300
Cassette Shutter Field Option Kit Field Installable Option Kit for drawout cassette for installation by customer.
Magnum Breaker Frame
PolesContinuous Rating (A)
Shutter Kit Catalogue Numbers List Price in US$
NarrowStandardDouble
NarrowStandardDouble
3 Pole3 Pole3 Pole
4 Pole4 Pole4 Pole
800-2000800-32004000-6300
800-2000800-32004000-6300
MDNSHTR3PMISHTR332MISHTR363
MDNSHTR4PMISHTR432MISHTR463
$168$180$354
$204$234$408
Cassette Cell Switch Field Option Kit Field Installable Option Kit for drawout cassette for installation by customer.
Switch changes position when breaker is levered to “Connect” position.
Kit includes switch, mounting bracket, and hardware for customer installation.
Switch kits include pre-installed wiring for easy field installation to cassette cell secondary terminal blocks.
Magnum Breaker Frame& Cassette Types
Catalogue Number
Description Type List Price in US$
AllAllAllAll
MICELLSW1M4CSM8CSM12CS
4 Form C Contacts4 Form C Contacts8 Form C Contacts12 Form C Contacts
Switch OnlyKit With Mounting BracketKit With Mounting BracketKit With Mounting Bracket
$52 $62 $104 $156
Cassette Cell Lock Provision Field Option Kit Field Installable Option Kit for drawout cassette for installation by customer.
Kit includes mounting provisions for single or multi-cylinder Kirk or Castell
lock provided and fitted to cassette by customer.
Catalogue numbers Lock List Price in US$
MCASSPRLMCASSPRR
Left sideRight side
$83 $83
Price ListEffective: May 2003 Page 13
Magnum IEC Air Circuit Breakers
Field Installable Option Kits for ACBsSecondary Contact Wiring Kits Field installation kits for use in wiring fixed or drawout breaker cassette secondary contacts or adding option kits in field.Each kit can be used to complete up to 3 breakers, depending on the number of accessories required for the breaker.
Description Catalogue Number Kit Contents List Price in US$
Secondary Terminal Block KitSecondary Terminal Wire KitSecondary Terminal Wire Kit
Secondary Terminal Kit With Tool (1)
MSECBKMSECWRMWK40
MSECTOOL
Qty 15 6-Point Terminal Blocks With LabelsQty 90 Wires for Connecting Secondary Blocks
Qty 30 Wires 40 Inches Long for Fixed ACB Connecting Secondary BlocksQty 12 Wires, Qty 2 6-Point Terminal Bocks, & 1 Amp, Inc Removal Tool
$310 $172
Contact C-HContact C-H
Shunt Trip Attachment (STA) Field Option KitField Installable Option Kit for Fixed or Drawout Breakers.Includes STA with plug-in wires, Cut-off Switch, & Instructions.Refer applications requiring capacitor trip devices to C-H.
Voltage (AC:50/60 Hz) Catalogue Numbers List Price in US$
110/127Vac/dc208/250Vac/dc
24Vdc48Vdc
MST1MST2MST3MST4
$235 $235 $235 $235
Motor Operator Field Option KitField Installable Option Kit for Fixed or Drawout Breakers.Kit includes motor operator assembly, motor cut-off switch, & Instructions.
Voltage (AC:50/60 Hz) Catalogue Numbers List Price in US$
110/125Vac220/250Vac
24 Vdc48Vdc
110/125Vdc220/250Vdc
MMOTNMMOTPMMOTLMMOTKMMOTWMMOTT
$1,125 $1,125 $1,125 $1,125 $1,125 $1,125
Spring Release Device (SRD) Field Option KitField Installable Option Kit for Fixed or Drawout Breakers.Includes SRD assembly with plug-in wires, and instructions.
Voltage (AC:50/60 Hz) Catalogue Numbers List Price in US$
110/127Vac/dc208/250Vac/dc
24Vdc48Vdc
MSRAMSRRMSRCMSRH
$235 $235 $235 $235
Latch Check Switch Field Option KitField Installable Option Kit for Fixed or Drawout Breakers.Includes LCS assembly 1 Form C contact, plug-in wires, and instructions.
Catalogue Numbers Description List Price in US$
MLSC1MLSC2
Latch Check Switch for Wiring Internally to Spring ReleaseLatch Check Switch With 1 Form C Contact For Remote Indication
$210 $210
(1) Pin Removal Tool can be purchased directly from AMP Corporation under Part Number # 3205183
Auxiliary Switch Field Option Kit Field Installable Option Kit for Fixed or Drawout Breakers.Note: 6a/6b maximum contacts on Standard and Double Frames. If more than 4a/4b contacts are required on the Narrow Frame,contact Cutler-Hammer.
Type Catalogue Number List Price in US$
2a/2b Contacts MAUX2 $100
Price ListPage 14 Effective: May 2003
Magnum IEC Air Circuit Breakers
Field Installable Option Kits for ACBsUndervoltage Release (UVR) Field Option KitField Installable Option Kit for Fixed or Drawout Breakers.
(1) Refer requests for Time Delay UVRs to C-H.(2) Digitrip 1150 Trip Units have an integral adjustable time delay UnderVoltage trip function from the line voltage. (3) An external customer supplied panel mounted Time Delay Undervoltage Relay can also be applied, wired
through the breaker secondary contacts to a Shunt Trip Attachment for Time Delay Undervoltage protection. (4) Each second Shunt Trip Attachment includes its own cut-off switch.
Voltage (AC:50/60 Hz) Catalogue Numbers UVR Release Type (1) (2) (3) (4) List Price in US$
110 - 127 Vac208 - 240 Vac
24 Vdc48 Vdc
110 - 125 Vdc220 - 250 Vdc
32 Vdc380 - 415 Vac
480 Vac600 Vac
MUVRAMUVRRMUVRCMUVRHMUVREMUVRFMUVRGMUVRXMUVRJMUVRK
InstantaneousInstantaneousInstantaneousInstantaneousInstantaneousInstantaneousInstantaneousInstantaneousInstantaneousInstantaneous
$408 $408 $408 $408 $408 $408 $408 $408 $408 $408
(1) Manual reset only.(2) For use with breakers that have mechanical pop-out trip indicator option already installed.
(1) The cover can be configured to block the Open and Close Pushbuttons or just the Close Pushbutton.
Trip Indication Field Option KitsField Installable Option Kit for Fixed or Drawout Breakers.
For breakers with trip units only, not available on Non-Automatic Breakers.
Trip Indication Kit Description (1) Contacts Catalogue Number List Price in US$
Mechanical Pop-out Trip Indicator Option KitBell Alarm / OTS Kit With Mechanical Trip Indicator
Bell Alarm / OTS Contact Field Option Kit (2)
None2 Form C2 Form C
MDTRINDMDTRINDBA
MOTS
$90 $352 $142
Breaker Key Lock Provisions Field Option KitField Installable Option Kit for Fixed or Drawout Breakers.
Kit includes mounting hardware and brackets to mount single cylinder lock forlocking breaker in the “Open” position.
Cylinder lock and key not included (Provided by customer).
Lock Type Catalogue Numbers Use With Customer Supplied Lock & Key Number List Price in US$
CastellRonisKirk
MBRLCKCMBRLCKRMBRLCKK
Castell # FGCL4008Ronis # 1104A
Kirk Lock # KC40---10 & Lock KC4
$87 $87 $87
Operation Counter Field Option KitField Installable Option Kit for Fixed or Drawout Breakers.
Note: Requires mechanical pop-out indicator kit if existingbreaker does not have one.
Operation Counter Kit Type Catalogue Number List Price in US$
Mechanical Counter MCOUNT $160
Padlockable Pushbutton Cover Field Option KitField Installable Option Kit for Fixed or Drawout Breakers.
Padlocks are not included. (Provided by customer).
Padlockable Cover Type (1) Catalogue Number List Price in US$
PlasticMetal
MCOVHMCOVC
$173 $173
Price ListEffective: May 2003 Page 15
Magnum IEC Air Circuit Breakers
ACB Sensor Accessories & External Neutral Current SensorSensor/Rating Plug Field Change-out KitsField installation kit for changing the sensor/rating plug rating on fixed or drawout breakers.Narrow and Standard Frame kits include Rating Plug plus 3 sensors for 3-pole or 4 sensors for 4-pole breakers.Double Frame kits include 1 Rating Plug plus 6 sensors for 3-pole or 8 sensors for 4-pole breakers.Rating Plug rating and sensor rating in kit match. Sensor amp rating selected cannot exceed the breaker frame and ampere rating.Note: For 3 pole breaker ground fault applications on 3 phase, 4 wire circuits, external mounted sensors must be ordered separately.
Magnum Frame Sensor Rating (A)3-Pole Catalogue
NumbersList Price in US$
4-Pole CatalogueNumbers
List Price in US$
NarrowNarrowNarrowNarrowNarrowNarrowNarrowNarrowNarrowNarrowNarrowNarrow
StandardStandardStandardStandardStandardStandardStandardStandardStandardStandardStandardStandardStandardStandardStandard
DoubleDoubleDoubleDoubleDoubleDouble
200250300400600630 800100012001250 16002000
200250300400600630 800100012001250 16002000250030003200
200025003200400050006300
M3NRG0200M3NRG0250M3NRG0300M3NRG0400M3NRG0600M3NRG0630M3NRG0800M3NRG1000M3NRG1200M3NRG1250M3NRG1600M3NRG2000
M3SRG0200M3SRG0250M3SRG0300M3SRG0400M3SRG0600M3SRG0630M3SRG0800M3SRG1000M3SRG1200M3SRG1250M3SRG1600M3SRG2000M3SRG2500M3SRG3000M3SRG3200
M3RRG2000M3SRG2500M3RRG3200M3SRG4000M3SRG5000M3SRG6300
$660 $660 $660 $660 $660 $660 $760 $760 $760 $760 $900 $900
$660 $660 $660 $660 $660 $660 $760 $760 $760 $760 $900 $900 $900 $900 $900
$1,420 $1,420 $1,700 $1,700 $1,700 $1,700
M4NRG0200M4NRG0250M4NRG0300M4NRG0400M4NRG0600M4NRG0630M4NRG0800M4NRG1000M4NRG1200M4NRG1250M4NRG1600M4NRG2000
M4SRG0200M4SRG0250M4SRG0300M4SRG0400M4SRG0600M4SRG0630M4SRG0800M4SRG1000M4SRG1200M4SRG1250M4SRG1600M4SRG2000M4SRG2500M4SRG3000M4SRG3200
M4RRG2000M4RRG2500M4RRG3200M4SRG4000M4SRG5000M4SRG6300
$880 $880 $880 $880 $880 $880
$1,013 $1,013 $1,013 $1,013 $1,200 $1,200
$880 $880 $880 $880 $880 $880
$1,013 $1,013 $1,013 $1,013 $1,200 $1,200 $1,200 $1,200 $1,200
$1,893 $1,893 $2,267 $2,267 $2,267 $2,267
Neutral Current SensorField Installable External Accessory for Fixed or Drawout BreakersFourth current sensor for mounting on enclosure neutral in 3 Pole breaker earth fault applications on 3 phase, 4 wire systems.
Magnum Frame Sensor RatingSensor Qty Requiredper 3 Pole Breaker
Catalogue Number List Price in US$
Narrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or StandardNarrow or Standard
DoubleDoubleDouble
200250300400600630 800100012001250 160020002500300031503200400050006300
1111111111111111222
9253C03H019253C03H029253C03H039253C03H049253C03H059253C03H149253C03H069253C03H079253C03H089253C03H159253C03H099253C03H109253C03H119253C03H129253C03H169253C03H139253C03H109253C03H119253C03H13
$280 $280 $280 $280 $280 $280 $300 $300 $300 $350 $350 $350 $350 $350 $350 $350 $350 $350 $350
Price ListPage 16 Effective: May 2003
Magnum IEC Air Circuit Breakers
External Accessories – Primary Terminal Adapter KitsPrimary Terminal Adapter KitsField installation kit for changing fixed breakers or drawout cassettes from horizontal to desired configurations.
Terminal Adapter KitType
Magnum Frame Type Breaker PolesInterrupting Rating
(kA)Breaker Continuous
Amps (A)Catalogue Number List Price in US$
VerticalVerticalVerticalVerticalVerticalVertical
VerticalVerticalVerticalVerticalVerticalVertical
Front MountFront MountFront MountFront MountFront MountFront Mount
Front MountFront MountFront MountFront MountFront MountFront Mount
NarrowStandardStandardStandardDoubleDouble
NarrowStandardStandardStandardDoubleDouble
NarrowNarrow
StandardStandardDoubleDouble
NarrowNarrow
StandardStandardDoubleDouble
3 Pole3 Pole3 Pole3 Pole3 Pole3 Pole
4 Pole4 Pole4 Pole4 Pole4 Pole4 Pole
3 Pole3 Pole3 Pole3 Pole3 Pole3 Pole
4 Pole4 Pole4 Pole4 Pole4 Pole4 Pole
Up to 65 kAUp to 65 kAUp to 100 kA
AllAllAll
Up to 65 kAUp to 65 kAUp to 100 kA
AllAllAll
Up to 65 kAUp to 65 kAUp to 65 kA
85kA & 100kAAllAll
Up to 65 kAUp to 65 kAUp to 65 kA
85kA & 100kAAllAll
800 - 2000800 - 1600Up to 20002500 - 3200
40005000 - 6300
800 - 2000800 - 1600Up to 20002500 - 3200
40005000 - 6300
800 - 1250800 - 2000800 - 2500800 - 3200
40005000 - 6300
800 - 1250800 - 2000800 - 2500800 - 3200
40005000 - 6300
MVADP320NMVADP16MVADP20MVADP32MVADP40MVADP50
MVADP420NMVADP416MVADP420MVADP432MVADP440MVADP450
NFC312KTNFC320KTSFNTC325SFNTC332
Contact C-HContact C-H
NFC412KTNFC420KTSFNTC425SFNTC432
Contact C-HContact C-H
$285 $285 $375 $475 $750 $950
$380 $380 $500 $575
$1,000 $1,150
Contact C-HContact C-HContact C-HContact C-HContact C-HContact C-H
Contact C-HContact C-HContact C-HContact C-HContact C-HContact C-H
Price ListEffective: May 2003 Page 17
Magnum IEC Air Circuit Breakers
A B
Type 2 Across 2 Breakers One Normal Power Supply (A)One Emergency Power Supply (B)
0 01 00 1
A B C
Type 31 Across 3 Breakers Two Normal Power Supplies (A and C)One Emergency Power Supply (B)
Circuit breakers A and C can be closed if Bis open. B can only be closed if A and C are open.
0 0 01 0 00 1 00 0 11 0 1
A B C
Type 32 Across 3 Breakers Two Power Supplies (A and C)One Bus Tie Breaker (B)
One or two breakers out of 3 can beclosed at the same time.
0 0 01 0 00 1 00 0 11 1 00 1 11 0 1
A B C
Type 33 Across 3 Breakers Three power supplies (A, B, and C)normal or emergency. Only one of which
can be closed at a time.
0 0 01 0 00 1 00 0 1
External Accessories – Mechanical Interlock Assembly KitsMechanical Interlock ConfigurationsReference Chart for Mechanical Interlock Kits.
Type of InterlockNumber of Breakers
InterlockedDescription of Interlocks
Possible InterlockLogic
Mechanical Interlock Assembly KitsField Installable External Accessory Kit for Fixed or Drawout Breakers.
Select Mechanical Interlock Kit and Rod or Cable Kits for complete assembly as indicated.
Configuration ofInterlocked Breakers
Type of Breaker Interlock Kit Type Catalogue Number List Price in US$ Comments
2 Way2 Way3 Way3 Way3 Way
2 Way2 Way3 Way3 Way3 Way
FixedFixedFixedFixedFixed
DrawoutDrawoutDrawoutDrawoutDrawout
Rod Type 2Cable Type 2Cable Type 31Cable Type 32Cable Type 33
Rod Type 2Cable Type 2Cable Type 31Cable Type 32Cable Type 33
MI2FRMI2FCMI31FCMI32FCMI33FC
MI2DRMI2DCMI31DCMI32DCMI33DC
$755$755
$1,205$1,305$1,205
$705$705
$1,155$1,255$1,155
This Kit also requires 1 Rod KitThis Kit also requires 1 Cable KitThis Kit also requires 2 Cable KitsThis Kit also requires 3 Cable KitsThis Kit also requires 3 Cable Kits
This Kit also requires 1 Rod KitThis Kit also requires 1 Cable KitThis Kit also requires 2 Cable KitsThis Kit also requires 3 Cable KitsThis Kit also requires 3 Cable Kits
Rod or Cable KitsField Installable External Accessory Kit for Fixed or Drawout Breakers.
Required for assembly of Mechanical Interlock Assembly Kits.
Kit Type Catalogue Number List Price in US$ Comments
Rod Type KitCable Type KitCable Type KitCable Type KitCable Type Kit
MIRMIC5MIC6MIC8MIC10
$225$485$515$555$595
Includes 2 Rods 3 Foot Long (910 mm) eachIncludes 2 Cables 5 Feet Long (1520 mm) eachIncludes 2 Cables 6 Feet Long (1830 mm) eachIncludes 2 Cables 8 Feet Long (2440 mm) eachIncludes 2 Cables 10 Feet Long (3050 mm) each
2-Way Cable Interlock
Price ListPage 18 Effective: May 2003
Magnum IEC Air Circuit Breakers
Description Catalogue Number Kit Contents/Accessory Function List Price in US$
Breaker Maintenance & Handling
Levering DeviceLifting Yoke (3 Pole Narrow Frame)
Lifting Yoke (3 Pole Standard Frame)Lifting Yoke (3 Pole Double Frame)Lifting Yoke (4 Pole Narrow Frame)
Lifting Yoke (4 Pole Standard Frame)Lifting Yoke (4 Pole Double Frame)
Roll on Floor Lifting Device
None Required8651C91G098651C91G028651C91G058651C91G108651C91G078651C91G086727D63H20
Special levering device not required. Use 10 mm Socket & Drive Set Fits 3 Pole Narrow Frame ACB
Fits 3 Pole Standard Frame ACBFits 3 Pole Double Frame ACBFits 4 Pole Narrow Frame ACB
Fits 4 Pole Standard Frame ACBFits 4 Pole Double Frame ACB
Lifts breaker fitted with lifting yoke from above
Contact C-H$225 $375
Contact C-HContact C-HContact C-H
$5,250
Miscellaneous Breaker & Enclosure Accessories
Door Escutcheon KitIP54 Door Cover Kit
Non-Automatic ACB CoverCassette Rejection Bracket Kit
Capacitor Unit for ACB Capacitor Trip
MDESMDESC
MTUNACIMCELLREJBK
Contact CH
Escutcheon, Gasket & Mounting HardwareIP54 Cover, Gasket & Mounting Hardware
Covers Trip Unit Cavity on Non-Automatic BreakersABC Rejection Kit (Cassette Mounting)
Enclosure Mounted AC Capacitor Unit for ACB Capacitor Trip
$90 $320
Contact C-H$87
Contact C-H
Breaker & Trip Unit Test Devices
Magnum Trip Unit TesterTriplink Cable
MTST15720B59G01
Hand-Held Tester for Digitrip 220, 520, 520M, & 520MC Trip UnitsDownloads Trip Unit Settings From One Digitrip RMS 1150 Trip to Another
$2,605 $475
Peripheral Devices
Mmint MODBUS TranslatorDigital Relay Accessory Module
MMINTDRAM
Translates INCOM for up to 32 Communicating Trip Units to ModbusUsed with Accessory Bus on Digitrip 1150 Trip Unit
$1,695 Contact C-H
Miscellaneous Accessories and Accessories for Breaker MaintenanceMiscellaneous Accessories
Price ListEffective: May 2003 Page 19
Magnum IEC Air Circuit Breakers
Breaker Catalogue Number FormatSelection Ordering Form for Magnum IEC Breaker Product FamilyExclusionary rules apply. Refer to price list. Confirm all final part numbers with Cutler-Hammer. Format structure subject to modificationsand additions without notice.
3. Breaker Frame
I = Standard or DoubleN = NarrowK = Special 1100 Vac ACB
16. Motor Operator
M = Manual OperatedN = 110 - 125 VacW = 110 - 125 VdcT = 220 - 250 VdcP = 220 - 250 VacL = 24 VdcK = 48 Vdc
21. Padlock Provisions for BlockingClose and/or OpenACB Manual Push Buttons
N = NoneM = Metal (Block Close & Open)P = Plastic (Block Close & Open)C = Metal (Block Close Only)H = Plastic (Block Close Only)
24. ACB Shipping Instructions
A = Fixed ACB with Door KitF = Fixed ACB w/o Door KitA = D/O ACB only w/o Door KitC = D/O ACB in Cassette (Un-Wired)P = D/O ACB in Cassette (Pre-wired)S = D/O ACB in Cassette (Shutters)W = D/O ACB in Cassette
(Pre-wired & Shutters)
Double Frame D/O ACBs Ship Without Cassette
25. Future Use
X = All ACBs
17. Spring Release Device (SRD)
N = NoneA = 110 - 127 Vac/dcR = 208 - 240 Vac/dcC = 24 VdcH = 48 Vdc
19. Auxillary Switch
N = None2 = 2A/2B4 = 4A/4B6 = 6A/6B
20. Bell Alarm Switch (OTS) with 2a/2b Contacts and/or Mechnical Trip Indicator
OTS 2a/2b Trip Indicator
E =N = Y =
No OTSNo OTSWith OTS
No IndWith IndWith Ind
22. Operations Counterand/or Keylock Provisions
Counter Keylock Provisions
N = KCRATLH
No CounterNo CounterNo CounterNo CounterCounterCounterCounterCounter
No LockKirk LockCastell LockRonis LockNo LockKirk LockCastell LockRonis Lock
23. Latch Check Switch / Trip UnitMetering Voltage Connection forDigitrip 1150 Trip Unit
Latch Check Sw
1150 VoltageConnection
N = M =L =
Y =
C =
D =
NoneNoneLCS Wiredto SRDLCS Wiredto SRDLCS WiredExternalLCS WiredExternal
Upper TerminalsLower TerminalsUpper Terminals
Lower Terminals
Upper Terminals
Lower Terminals
18. UnderVoltage Release (UVR)or 2nd ShuntTrip Attachment (STA)
N = NoneA = 110 - 127 VacR = 208 - 240 VacC = 24 VdcH = 48 VdcE = 110 - 125 VdcF = 220 - 250 VdcG = 32 VdcX = 380 - 415 VacJ = 480 VacK = 600 Vac1 = 2nd STA, 110 - 127 Vac/dc2 = 2nd STA, 208 - 240 Vac/dc3 = 2nd STA, 24 Vdc 4 = 2nd STA, 48 Vdc
11 & 12. Sensor & RatingPlug Rating
NN = None02 = 20005 = 25003 = 30004 = 40006 = 60007 = 63008 = 80010 = 100012 = 1200
13 = 125016 = 160020 = 200025 = 250030 = 300032 = 320040 = 400050 = 500063 = 6300
9. Nameplate Language
E = EnglishA = Spanish
4. Interrupting Icu
4 = 40kA5 = 50kA6 = 65kA8 = 85kAC = 100kA2 = 25kA (1100 Vac MWK)
13 & 14. Trip Unit & Protection, (& External Control Voltage When Required)
NN = Non-Automatic (No Trip Unit)22 = 220 LI52 = 520 LSI5W = 520i LSIGM2 = 520M LSIMT = 520M LSI (24 - 48 Vdc)MU = 520M LSI (120 Vac)MV = 520M LSI (240 Vac)MW = 520Mi LSIGMJ = 520Mi LSIG (24 - 48 Vdc)MK = 520Mi LSIG (120 Vac)ML = 520Mi LSIG (240 Vac)ME = 520M LSIA (24 - 48 Vdc)MC = 520M LSIA (120 Vac)MF = 520M LSIA (240 Vac)CT = 520MC LSICU = 520MC LSICV = 520MC LSICE = 520MC LSIACC = 520MC LSIACF = 520MC LSIACJ = 520MCi LSIGCK = 520MCi LSIGCL = 520MCi LSIG1W = 1150i LSI (24 - 48 Vdc)1N = 1150i LSI (120 Vac)1P = 1150i LSI (240 Vac)1R = 1150i LSIG/A (24 - 48 Vdc)1S = 1150i LSIG/A (120 Vac)1T = 1150i LSIG/A (240 Vac)
15. Shunt Trip Attachment (STA)
N = NoneA = 110 - 127 VacR = 208 - 240 VacC = 24 VdcH = 48 Vdc
5 & 6. Continuous Amperes & Phasing(Facing Front of Breaker)
08 = 800 ABC10 = 1000 ABC12 = 1250 ABC16 = 1600 ABC20 = 2000 ABC25 = 2500 ABC32 = 3200 ABC4N = 4000 AABBCC5N = 5000 AABBCC6N = 6300 AABBCC40 = 4000 ABCABC50 = 5000 ABCABC60 = 6300 ABCABC
7. Poles & Neutral (Facing Front of Breaker)
3 = Three4 = Four (Neutral Left)R = Four (Reserved for
Neutral Right)
8. Mounting Configuration & Load Terminals
H = Fixed HorizontalV = Fixed VerticalL = Drawout Horizontal
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
M W A – X
Price ListPage 20 Effective: May 2003
Magnum IEC Air Circuit Breakers
1. Cassette Family
E = Standard or DoubleFrame IEC(690 & 1100 Vac)
N = Narrow Frame IEC
6. Rear Terminals
H = Hoizontal Stabs (Upper& Lower Terminals)
7. Arc Hood
A = Arc Hood FOR 690 VacK = Arc Hood for 1100 Vac
8. Future Use
N = All Cassettes
9. Future Use
N = All Cassettes
10. Shutters
N = No ShuttersS = Shutters Installed
2. Future Use
N = All Cassettes
3 & 4. Continuous Amperes
20 = Up to 2000 Amps32 = 2500 to 3000 Amps40 = 4000 amps63 = 5000 to 6300 Amps
5. Poles
3 = Three Pole4 = Four Pole
11. Future Use
N = All Cassettes
12. Future Use
N = All Cassettes
13. Door Frame & Gasket Kit
X = Door Frame & Gasket Kit IncludedD= Door Frame & Gasket Kit Not
Included
14. Cassette Wiring
N = Un-WiredW = Cassettes Wired
15. Cassette Shipping
C = Cassette Only
Magnum IEC Cassettes for Drawout Circuit Breakers – Cassette Catalogue Number FormatSelection Ordering Form for Magnum IEC Breaker Product FamilyExclusionary rules apply. Refer to price list. Confirm all final part numbers with Cutler-Hammer. Format structure subject to modificationsand additions without notice.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
N H N N N N N C
Back Cover