 ASME 831 3 INTERPRETATIONS SME 831.3 I NTERPRET TIONS VOLUME 24 Replies to Technical Inquiries April 30  2012 through December 16 2013 GENER L INFORM TION t ha s been agreed to publish interpretations issu ed by the B31 Committee concerning B31.3 as part of the update service t o th e Code. The interpretations have been assigned numbers in chronological order. Each interpretation applies to the Edition stated in the interpretation, or if none is stated, to the Edition in effect on the date of issuance of the interpretation. Subsequent revis i ons to the Code may have superseded the r ep l y These replies are taken verbatim from the original letters, except for a few typographical and editorial corr ecti ons made for the purpose of improved clarity. In some instances, a review of the interpretation revealed a need for corrections of a technical nature. ln the se cases, a revised reply bearing the original interpretation number with the suffix R is presented. ln the case where an interpretation is corrected by errata, the original interpretation number with the suffix Eis used. ASME procedures pr o vide for reconsideration of these interpretations when or if addit i onal infom1ation is available which the inquirer believes might affec t th e interpretation. Further, persons aggrieved by an interpretati on may appeal to the cognizant ASME committee or subcom- mittee . As st a ted in the Statement of Policy in the Code documents, ASME does not approve, certify, rate, or e nd orse an y item, constructi on, proprietary devic e, or activity. For detailed instructio n s on preparation of technical inquiries to the 831 Committee, refer to Appendix Z NUMERIC L ND SUBJECT IND E XES Numerical and Subject Indexes have been prep ar ed to assist the user in locatin g interpretations by location or by subject matter in the Code. They cove r interpretations issued from Volume 1 up to and including the present volume, and wiU be updated with each volume. 1 1 Co p yr i g ht © 2015 by the American Soc iety of Mechani cal Engineers. No reproduction may be made of this material without writien co nsent of ASME.

description

Interpretations B31.3

Transcript of Interpretations 24 B31.3

  • ASME 831.3 INTERPRETATIONS

    ASME 831.3 INTERPRETATIONS VOLUME 24

    Replies to Technical Inquiries April 30, 2012 through December 16, 2013

    GENERAL INFORMATION

    It has been agreed to publish interpretations issued by the B31 Committee concerning B31.3 as part of the update service to the Code. The interpretations have been assigned numbers in chronological order. Each interpretation applies to the Edition stated in the interpretation, or if none is stated, to the Edition in effect on the date of issuance of the interpretation. Subsequent revisions to the Code may have superseded the reply.

    These replies are taken verbatim from the original letters, except for a few typographical and editorial corrections made for the purpose of improved clarity. In some instances, a review of the interpretation revealed a need for corrections of a technical nature. ln these cases, a revised reply bearing the original interpretation number with the suffix R is presented. ln the case where an interpretation is corrected by errata, the original interpretation number with the suffix Eis used.

    ASME procedures provide for reconsideration of these interpretations when or if additional infom1ation is available which the inquirer believes might affect the interpretation. Further, persons aggrieved by an interpretation may appeal to the cognizant ASME committee or subcom-mittee. As stated in the Statement of Policy in the Code documents, ASME does not "approve," "certify," "rate," or "endorse" any item, construction, proprietary device, or activity.

    For detailed instructions on preparation of technical inquiries to the 831 Committee, refer to Appendix Z.

    NUMERICAL AND SUBJECT INDEXES

    Numerical and Subject Indexes have been prepared to assist the user in locating interpretations by location or by subject matter in the Code. They cover interpretations issued from Volume 1 up to and including the present volume, and wiU be updated with each volume.

    1-1

    Copyright 2015 by the American Society of Mechanical Engineers. ~ No reproduction may be made of this material without writien consent of ASME. ~

  • ASME 831.3 INTERPRETATIONS

    831.3 Subject

    Chapter IX, I ligh Pressure Piping (1331.3-2012) ..................... .... .... Fig. 323.2.28, Design Minimum Temperature According to ASME 631T

    (631.3-2010) ... ........ . .. . ... ...... . . .. ... . ... .. .. .. .... . ... .. ... . .. Para. 302.3.6(a), Limits of Calculated Stresses Due to Occasional Loads

    (831.3-2012) . . . . . . . . . . . . . . . . . . . . .................................. .. Para. 304.7.2, Pressure Design (1331.3-2010) ...... ...... .... ..... ..... ...... . . Para. 307.1.2, Qualification of Valve Pressure Design (831.3-2010) ... .... .. . Para. 322.6.3, Rclicl Devices (631.3-2012) . . ... .... .... ....... . . ....... . ..... Para. 323.3.5, Acceptance Criteria (631.3-2012) ...... . ................. . ..... . Para. 328.5.4 and Fig. 328.5.40, Welded Branch Connection (631.3-2010) . ..... . Para. 328.5.4, Welded Bra nch Connections (631.3-2010) . .. .. . . . ........ . . Paras. 328.5.4(d) and (e), Use of a Branch Connection Where the

    Abutting Branch Pipe Is Not Welded to the Run (1331.3-2012) .............. . Para. 340.4(a), Owner's Inspectors (631.3-2010) ........ .. ..... . . ... .. .... . .. . Para. 341.3.l (a), NOE After PWHT for P-Nos. 3, 4, and 5 Materials

    (631.3-2010) ..... .. ........ . .. ...... . ................................. . Para. 341.3.3, Defective Components and Workmanship (631.3-1996

    Ed it ion Through 831.3-2012) .. ...... . .. . ... .... . .. ... .... . ........ . Para. 341.4.l(b), Sample Ex:1minat ions (631.3-2010) .. . .... . . ...... .. ........ . Para. 341.4.l(b)(l), Prequalification of Welds by Random Examination

    (631.3-2012) ...... . .. .................. .. ... .... ................. .. ... . Paras. 344.2.1 and 342.1, Visual Examinaticm (631.3-2012) . ... ... .. .. ... . . .... . Para. 345, Pneumatic Leak Testing (631.3-2010) .... ..... .... ..... .... . . Para. 345.2.2(a), Examination During Leak Testing (631.3-1996 Edition Through

    631.3-2010) ..... ..... .... ...... ..... .. . ....... .. . . ... ..... ..... . . .. ... . Para. 345.2.3(b), Flanged joints (631.3-2010) . .. ... . .. .. .. ... . .. . .. ... . .. .. . Para. 345.2.3(c), Closure Welds (631.3-2012) ...... . . .. ............ ... ...... Para. 1

  • ASME 831.3 INTERPRETATIONS

    Interpretation 24-01

    Subject: Table 323.2.2, Notes (3) and (5), Impact Testing (831 .3-2010)

    Date Issued: April 30, 2012

    File: 12-57

    Question: Jn accordance with ASME 831.3-2010, if a material meets the requirements of Table 323.2.2, Note (3) exception to impact testing requirements, does it matter what size specimen is obtainable as described in Note (5)?

    Reply: No.

    Interpretation 24-02

    Subject: Table 341.3.2 and Paras. 341.4.1, 341.4.2, and M341.4, Radiography for Fillet Welds (831.3-2010)

    Date Issued: April 30, 2012

    File: 12-102

    Question: ln accordance with ASME 831.3-2010, is it a requirement to perform radiography on fillet welds?

    Reply: No.

    Interpretation 24-03

    Subject: Table 341.3.2, Acceptance Criteria (831.3-2010)

    Date Issued: April 30, 2012

    File: 12-241

    Question: In accordance with ASME 831.3, if indications are detected in the base metal or a weld not required to be examined, are the indications required to be evaluated?

    Reply: The Code does not specifically address this issue. However, the Introduction states that the owner is responsible for imposing requirements supplementary to those of the Code if necessary to assure safe piping for the proposed installation. Also see para. 300(c)(4).

    1-3

    Copyrigh1 20 15 by the American Society of Mechanical Engineers. lfil1 No reproduction may be made of this material wilhoul wrillen consent of ASM E. ~

  • ASME 831.3 INTERPRETATIONS

    Interpretation 24-04

    Subject: Fig. 323.2.26, Design Minimum Temperature According to ASME B31T (631.3-2010)

    Date Issued: Apri I 30, 2012

    File: 12-243

    Question (1): In accordance with ASME 831.3-2010, may Fig. 323.2.28 be used for impact-tested materials in the same manner as described in the ASME 8PV Code rules?

    Reply (1): No. See interpretation 20-13R.

    Question (2): [n accordance with ASME 831.3-2010, is the use of ASME 831 T, Standa rd Toughness Requirements for Piping, mandatory?

    Reply (2): No.

    Question (3): In accordance with ASME 831.3-2010, does Fig. 323.2.28 apply to UNS 531803 (22Cr duplex)?

    Reply (3): No.

    Interpretation 24-05

    Subject: Para. 340.4(a), Owner's Inspectors (631.3-2010)

    Date Issued: April 30, 2012

    File: 12--199

    Background: An EPC (Engineering, Procu rement, and Construction) contractor has been awarded a contract to engineer, procure, construct, and install a pressure piping system.

    Question (1): Does ASME 831.3 allow an EPC contractor to act as the owner's inspector until the piping system is complete and ready to be turned over to the owner?

    Reply (1): No.

    Question (2): Does J\SME 831.3 allow the owner to designate in writing an employee of the EPC contractor to act as the owner's inspector until the piping system is complete and ready to be turned over to the owner?

    Reply (2): No.

    1-4

    Copyright 2015 by the American Society of Mechanical Engineers. ~. No reproduction may be made oflhis material without written consent of ASME. W.

  • ASME 831.3 INTERPRETATIONS

    Interpretation 24-06

    Subject: Para. K328.2.1{b), Welding Qualifications (B31.3-2010)

    Date Issued: April 30, 2012

    File: 12-623

    Question (1): In accordance with ASME 831.3-2010, is a separate qualification of the welding procedure required for each combination of base material specification(s) forming a joint in Chapter IX, 1-:!igh Pressure Piping, even if the material type or grade remains the same?

    Reply (1): Yes; see para. K328.2.l(b).

    Question (2): In accordance with ASME 831.3-2010, if a welded joint comprised of two different material spec ifications with the same type or grade in Chapter lX, High Pressure Piping, is qualified, does the welding procedure also qualify welding of each individual base material to itself?

    Reply (2): No; see para. K328.2.1(b).

    I-5

    Copyright 20 15 by the American Society of Mechanical Engineers. ~ No reproduction may be made of this material without written consent of ASME. ~

  • ASME 831.J INTERPRETATIONS

    Interpretation 24-07

    Subject: Pa ra. 345.2.2(a), Exam ination During Leak Testing (631.3-1996 Edition Through 631 .3-2010)

    Date Issued: October 5, 2012

    File: 12-56, 12-666

    Question (1): In accordance with ASME 631.3-1996 Edition through ASME 631.3-2010, para. 345.2.2(a), must examination for leaks be performed in accordance with the visual examination method in para. 344.2?

    Reply {l): No.

    Question (2): Other than sensitive lea k testing, do ASME 8 31.3-1996 Edition through ASME 831.3-2010, define leak testing examination requirements?

    Reply (2): No.

    Question (3): ln accordance with ASME 631.3-1996 Edition through ASME 831.3-2010, para. 345.2.2(a), must personnel performing the examination for leaks be qualified for visual examina-tion per paras. 342.1 or 344.2?

    Reply (3): No.

    Question (4): In accordance with ASME 831.3-1996 Edition through ASME 631.3-2010, para. 345.2.2(a), must leak testing be performed in accordance with a written procedure for visual examination?

    Reply (4): No.

    Question (5): Other than sensitive leak testing, do ASME 631.3-1996 Edition through ASME 831.3-2010 require compliance with the requirements of ASME BPV Code Section V, Articles 9 or 10 for leak testing?

    Reply (5): No.

    Question (6): In accordance with ASME 631.3-1996 Edition through ASME 831.3-2010, during a hydrostatic lea k test, if the examiner is satisfi ed that the requirements of para. 345.2.2(a) are met, is a 100% visual examination (i.e., a visual examination of 360 deg of the pipe or joint surface) of each joint or connection required?

    Reply (6): No.

    Interpretation 24-08

    Subject: Para. 341.4.l{b), Sample Examinations (831.3-2010)

    Date lssued: October 5, 2012

    File: 12-1071

    Question: If one welder makes the tack welds in a circumferential butt weld and another welder welds the root pass and remainder of the weld, is it required that the welder who made the tack welds be represented in the sample examinations required by para. 341.4.1 (b) or the progressive sampling of para. 341.3.4?

    Reply: No.

    I-6

    Copyright 20 I 5 by the American Society of Mechanical Engineers. ~ e No reproduction may be made of this material without written consent of ASME.

  • ASME B31.3 IN'TfRPRETATIONS

    Interpretation 24-09

    Subject: Para . 304.7.2, Pressure Design (631.3-2010)

    Date Issued: October 5, 2012

    File: 12-1504

    Question: In accordance with ASME 631.3-2010, para. 307.1.2, Unlisted Valves, if valve pressure-temperature ratings are established by the method set forth in ASME 616.34, Appendix B, is it necessary to qualify the pressure design in accordance with ASME 831.3, para. 304.7.2?

    Reply: No.

    Interpretation 24-10

    Subject: Para. 328.5.4, Welded Branch Connections (831.3-2010)

    Date Issued: October 5, 2012

    File: 12-1584

    Question: In ASME 831.3-2010, for the installation of instrument tap type branch connections, do the weld types specified in ASME Section VIII, Division 1, UW-15(b) (i.e., welds that require no strength calculations) and corresponding acceptable welding types shown in UW-16, which include not-fully-penetrated branch connection groove welds, comply with the acceptable welding details shown in ASME 631.3, para. 328.5.4?

    Reply: No; however, see para. 300(c)(3).

    Interpretation 24-11

    Subject: Para. 345, Pneumatic Leak Testing (831.3-2010)

    Date Issued: October 5, 2012

    File: 12-1610

    Question: Jn accordance with ASME 831.3-2010, para. 345.5.4(a), with or without the owner's approval, does the Code permit pneumatic testing in excess of 1.33 times the design pressure?

    Reply: No; however, see para. 300(c)(3).

    1-7

    Copyright 20 15 by lhe /\mcrican Society of Mechanical Engineers. ~ No reproduction may be made of this material without written consent of ASME. ~

  • ASME 831.3 INTERPRETATIONS

    Interpretation 24-1 2

    Subject: Table 302.3.5, Weld Joint Strength Reduction Factor, W (631.3-2010)

    Date Issued: October 5, 2012

    File: 12-1728

    Question (1): ln accordance with ASME 831.3-2010, Table 302.3.5, is the weld strength reduction factor, W, for P91 alloy steel material (CSEF subcritical) at 950F equal to 0.5?

    Reply (1): Yes.

    Question (2): In accordance with ASME 831.3-2010, Table 302.3.5, should the weld strength reduction factor, W, for P91 alloy steel material be the same value as in ASME 831.1-2010?

    Reply (2): The ASME 831.3 Committee is unable to provide the information you have requested. The Committee does not respond to requests for rationaJe. Code rules reflect not only technical data and safety criteria, but also the collective experience of the Committee members. interdepen-dence of rules in various Chapters also plays a part in any given requirement.

    If you believe, however, that a particular Code rule or rules may benefit from consideration of new or additional data and approaches, the Committee welcomes your desire to contribute. We invite you to submit pertinent material for transmittaJ to the Code Section Committee involved.

    If you desire, an invi tation can be extended for you to attend a meeting of the Committee at which the material will be discussed. We appreciate your interest.

    1-8

    Copyright 2015 by the American Society of Mechanical Engineers. & No reproduction may be made of this material without written consent of ASME.

  • ASME 831.3 INTERPRETATIONS

    Interpretation 24-13

    Subject: Chapter IX, High Pressure Piping (831.3-2012)

    Date Issued: April 15, 2013

    File: 12-1782

    Question (1 ): Does ASME 831.3-2012 require compliance with Chapter IX, High Pressure Piping, under any circumstance other than when such compliance is specified by the owner?

    Reply (1): No; see para. K300(a).

    Question (2): Does ASME 631.3-2012 require that piping designed for a pressure in excess of that allowed by ASME 616.5, Class 2500 rating for the specified design temperature and material group be designed in accordance with Chapter IX if the piping system is not designated by the owner as being in High Pressure Fluid Service?

    Reply (2): No; see para. K300(a).

    Interpretation 24-14

    Subject: Table 323.3.1, Impact Testing for Metals (831.3-2010)

    Date Issued: April 15, 2013

    File: 12-2057

    Question (1 ): Do rows 4 through 7 of Table 323.3.l of ASME 831.3-2010 apply to welds used in the manufacture of piping components?

    Reply (1): No.

    Question (2): Do rows 1 through 3 of Table 323.3.1 of ASME 831.3-2010 apply to welds used in the manufacture of piping components?

    Reply (2): Yes.

    Interpretation 24-15

    Subject: Para. 328.5.4 and Fig. 328.5.40, Welded Branch Connection (831.3-2010)

    Date Issued: April 15, 2013

    File: 13-76

    Question: Does ASME 831.3-2010 permit the use of a complete (full) encirclement split-tee as a branch connection, where a branch pipe is butt welded to the branch opening of the split-tee, if the requirements of paras. 303 and 304.7.2 are met?

    Reply: Yes. Sec also paras. 300(c)(3) and 300(c)(4).

    Interpretation 24-16

    Subject: Para. 322.6.3, Relief Devices (831.3-2012)

    Date Issued: April 15, 2013

    File: 13-266

    Question: Does ASME 831.3 require that all relief devices that meet para. 322.6.3 but not A Pl 526 be evaluated as unlisted components?

    Reply: Yes; see para. 302.2.3.

    I-9

    Copyright 2015 by the American Society of Mechanical Engineers. ~ e No reproduction may be made of this material without wri tten consent of ASME.

  • ASME 831.3 INTERPRETATIONS

    Interpretation 24-17

    Subject: Para. K328.2.1(d), Welding Qualifications (831.3-2010)

    Date Issued: April 15, 2013

    File: 13-474

    Question (1): In accordance with ASME 831.3-2010, para. K328.2.1(d), if transverse tensile testing is required for a full penetration groove weld test coupon for Welding Procedure Qualification in accordance with the ASME BPV Code, Section IX, shall yield strength be determined on the transverse tensile test coupon?

    Reply (1): Yes.

    Question (2): In accordance with ASME 831.3-2010, para. K328.2.1(d), shall all-weld-metal tensile testing be conducted and the yield strength of the weld be determined if transverse tensile testing is required for a full penetration groove weld test coupon for Welding Procedure Qualification in accordance with the ASME BPV Code, Section fX?

    Reply (2): No, unless the filler metal is not yet incorporated into Section IX (see para. K328.3.1).

    Interpretation 24-18

    Subject: P;.ua. 307.1.2, Qualification of Valve Pressure Design (631.3-2010)

    Date Issued: April 15, 2013

    File: 13-509

    Question: Does para. 307.1.2 of ASME 831.3-2010 permit a valve manufactured from a material not listed in ASME 816.34 to have the pressure-temperature rating established i.n accordance with the method set forth in ASME 816.34?

    Reply: Yes.

    Interpretation 24-19

    Subject: Para. 345.2.3(b), Flanged Joints (831.3-2010)

    Date Issued: April 15, 2013

    File: 13-620

    Question (1): In accordance with ASME 631.3-2010, do components listed in Table 326.1 need to be leak tested in accordance with para. 345?

    Reply (1): We believe your question can be answered by previous interpretation 23-14.

    Question (2): Does the phrase "previously been tested" in para. 345.2.3(b) refer to leak testing in accordance with the requirements of ASME 631.3?

    Reply (2): Yes.

    Interpretation 24-20

    Subject: Random Examination (831.3-2012)

    Date Issued: April 15, 2013

    File: 13-704

    Question: Does ASME 831.3-2012 prohibit commencement of random examination prior to completion of all welds in a designated lot?

    Reply: No.

    I-10

    Copyright 20 15 by the American Society of Mechanical Engineers. ~ e No reproduction may be made of this material without written consent of ASME.

  • ASME 831.3 INTERPRETATIONS

    Interpretation 24-21

    Subject: Paras. 344.2.l and 342.1, Visual Exam ination (B31 .3-2012)

    Date Issued: October 3, 2013

    File: 13-710

    Question (1 ): Does ASME B31.3-2012 have any qualification requirements for visual examiners performing Code-required examinations?

    Reply (1): Yes. See paras. 342.1 and 344.2.

    Question (2): Does ASME B31.3-2012 require individuals that check the fit and alignment of weld joints during fabrication to be qualified for visual examination as described in paras. 342.1 and 344.2?

    Reply (2): No.

    Interpretation 24-22

    Subject: Para. 341.4.l(b)(l), Prequalification of Welds by Random Examination (831.3-2012)

    Date Issued: October 3, 2013

    File: 13-786

    Question: When ASME 831.3-2012, para . 341.4.l(b)(l) requires random exam ination of 5% of circumferential girth or miter groove welds by radiography or ultrasonk examination for Normal Fluid Service, must all welds in the lot be completed prior to the completion of the required examinations on the selected welds?

    Reply: The Code does not address this issue. See previous interpretations 2-12 and 24-20.

    Interpretation 24-23

    Subject: Paras. 328.5.4(d) and (e), Use of a Branch Connection Where the Abutting Branch Pipe Is Not Welded to the Run (B31.3-2012)

    Date Issued: October 3, 2013

    File: 13-789

    Question: Under the rules of ASME B3l.3-2012, may a branch connection be added to a piping run using branch attachment details other than specified by para. 328.5.4(d), which require fully penetrated groove welds to the run pipe, or para. 328.5.4(e)?

    Reply: No, unless qualified in accordance with paras. 300(c)(3), 300(c)(4), and 304.7.2.

    1-11

    Copyright 2015 by the American Society of Mechanical Engineers. ~ e U> s

    No reproduction may be made of this material without written consent of ASME.

  • ASME 831.3 INTERPRETATIONS

    Interpretation 24-24

    Subject: Para. 302.3.6(a), Limits of Calculated Stresses Due to Occasional Loads (831.3-2012)

    Date Issued: October 3, 2013

    Pile: 13-1331

    Question (1): Is the final paragraph in para. 302.3.6(a) applicable to castings only?

    Reply (1): Yes.

    Question (2): Does ASME 831.3 permit the occasional stress of austenitic steel piping to rise above yield?

    Reply (2): Yes; however, see para. 302.3.2(e).

    Interpretation 24-25

    Subject: Para. 345.2.3{c), Closure Welds (831.3-2012)

    Date Issued: October 3, 2013

    File: 13-1499

    Question: lf a pipe is bent in accordance with para. 306.2, can it be installed using closure welds without being leak tested in accordance with para. 345?

    Reply: No.

    Interpretation 24-26

    Subject: Para. 323.3.5, Acceptance Criteria (831.3-2012)

    Date Issued: October 3, 2013

    File: 13-1508

    Question (1): In accordance with ASME 831.3-2012, para. 323.3.S(a), do the acceptance criteria for minimum energy requirements apply to carbon and low alloy steels having specified minimum tensile strengths equal to or greater than 656 MPa (95 ksi) or for high alloy steels (P-Nos. 6, 7, and 8)?

    Reply {l): No. Sec para. 323.3.S(b) for acceptance criteria for these materials.

    Question (2): In accordance with ASME 831.3-2012, para. 323.3.5(c), are the acceptance criteria for weld impact test requirements applicable for clad-pipe to clad-pipe welds?

    Reply (2): No. See paras. 323.3.S{a) and 323.3.5{b).

    Question (3): In accordance with ASME 831.3-2012, para. 323.3.S{c), when dissimilar base metals (e.g., Pl and P8) are joined by welding and the weld metal has a tensile strength most closely matching that of the P8 base material, shall the acceptance criteria for impact tests conform to the lateral expansion requirements of para. 323.3.S(b)?

    Reply (3): Yes.

    1-12

    Copyright 20 I 5 by the American Society of Mechanical Engineers.

  • ASME 831.3 INTERPRETATIONS

    Interpretation 24-27

    Subject: Table 323.2.2, Low Temperature Toughness Tests for Metals (B31.3-2008)

    Date Issued: October 3, 2013

    File: 13-1548

    Question: In accordance with ASME 631.3-2008, when ASTM 8423 N08825 base metal is welded by SFA-5.14 ERNiCrMo-3 N06625 filler metal, do the rules of Table 323.2.2, Box A-6(b) require that testing in accordance with Box B-6 be performed?

    Reply: Yes.

    Interpretation 24-28

    Subject: Table 323.3.1, Impact Testing Requirements for Metals (631.3-2008)

    Date Issued: October 3, 2013

    File: 13-1549

    Question: In accordance with ASME 831.3-2008, Table 323.3.1, box A-5, is the qualified thickness range T / 2 to T + 6 mm (!'4 in.)?

    Reply: Yes. Also see previous Interpretation 4-17.

    Interpretation 24-29

    Subject: Para. 341.3.3, Defective Components and Workmanship (831.3-1996 Edition Through 831 .3-2012)

    Date Issued: December 12, 2013

    File: 13-709

    Question: ls it the intent of ASME 631.3-1996 Edition through ASME 831.3-2012, para. 341.3.3 to allow replacement welds for rejected welds to be examined by any nondestructive (NOE) method that is allowed for the original welds, as it is for high pressure piping system welds in K341.3.3, rather than requiring the same NDE method as used on the original defective welds?

    Reply: Yes.

    Interpretation 24-30

    Subject: Para. 341.3.l(a), NOE After PWHT for P-Nos. 3, 4, and 5 Materials (831.3-2010)

    Date Issued: December 16, 2013

    File: 11-1769

    Question: A piping assembly made of P-No. 5 material consisting of severa l welds is furnace heat treated and radiographed. One of those welds is defective and repaired. The assembly is then heat treated again. ls it the intent of para. 341.3.l(a) that all of the welds in that piping assembly be radiographcd again?

    Reply: No.

    1-13

    Copyright 20 15 by lhe American Society of Mechanical Engineers. ~ No reproduction may be made oflhis material without wri tten consent of ASME. ~