International Spec Series 6 kVA - 830 kVA, 50 HzPOWER SYSTEMS CATALOG 8 kW - 750 kW, 60 Hz
15-03517_IntlSpecA4.indd 1 3/2/16 11:19 am
Critical power applications are part of every industry; protecting them starts with reliable KOHLER® generators, available in diesel, natural gas and LP gas configurations. Our diesel models deliver dependable power to a wide range of output requirements. From small-load residential and business to heavy industry, every KOHLER generator is engineered to provide maximum power, performance, flexibility and fuel efficiency.
Today, Kohler provides integrated solutions to streamline the specifying process. Our industrial generators are diesel-fueled models — ranging from 6 kVA to 3,300 kVA @ 50 Hz (8 kW to 3,250 kW @ 60 Hz) complete with electronic controls and automatic transfer switches. To help cater to unique installation environments, we also offer a range of accessories, including controls, silencers, enclosures, fuel tanks and block heaters.
Disclaimer: Information in this publication represents product data available at the time of print. Kohler reserves the right to change this publication and the products represented without notice and without any obligation or liability.
KOHLER POWER SYSTEMS Headquarters and Manufacturing – Kohler, WI
Headquarters EMEA
Headquarters Southeast Asia and Manufacturing – Singapore
Manufacturing Facility – India
Manufacturing Facility – China
Sales Offices, Dealers and Distributors
SDMO (Kohler-Owned) Headquarters and Three Manufacturing Facilities – France
Manufacturing Facility – Brazil
Sales Offices, Dealers, and Distributors
DEPENDABLE POWER AND PERFORMANCETESTED, TRIED AND PROVEN TO WORK.
2
15-03517_IntlSpecA4.indd 2 3/2/16 11:19 am
Anybody can claim to offer an unrivaled level of support, but it is another thing to deliver on that promise. Today, Kohler distribution network spans across multiple sales offices in countries throughout the Asia Pacific region.
Unlike other generator manufacturers, Kohler certified distributors and dealers specialize in power. This means our service network can be called on for anything related to your generator and its components.
With Kohler, you enjoy world-class service and support from a global service network.
SERVICE AND SUPPORTTHE HELP YOU NEED. ANY TIME, ANYWHERE.
SPEC YOUR JOB AT KOHLERPOWER.COM.SG 3
15-03517_IntlSpecA4.indd 3 3/2/16 11:19 am
TOTAL SYSTEM INTEGRATION.EVERYTHING WORKS TOGETHER.
Reliability of power systems is critical. Your business depends on it. At Kohler, we build industrial power systems that are proven to work because total system integration is engineered in from the start.
For more than 90 years, Kohler has earned a global reputation as a pure power expert — in large part to our strict quality standards. Our power systems are equipped with Kohler innovation, including generators, transfer switches, switchgear and controllers. Enduring the industry’s toughest testing process, including transient power testing, cooling sound and more, every part is built to work with the entire system and perform in the most demanding environments before they are shipped out.
Our power systems are built for nearly every application, powering everything from gas stations to hotels and hospitals, as well as military operations and airports. So you can be rest assured that our products will work when you need them most.
KOHLER® GENERATOR8-3,250 kW diesel and 20-400 kW gas
TRANSFER SWITCHOpen, closed, programmed transition, bypass and service entrance
REMOTE ANNUNCIATORMonitors and tests your generator set and ATS from a remote location
PD-SERIES SWITCHGEARParallels multiple generators to each other or to the utility
DECISION-MAKER® CONTROLLERSKOHLER controls and diagnostics ensure reliable on-site power
WIRELESS MONITORMonitors your system’s performance around the clock
KOHLER MONITOR SOFTWAREProvides monitoring and adjustment of generator and ATS equipment
4
15-03517_IntlSpecA4.indd 4 3/2/16 11:19 am
6-830 kVA 8-750 kW
COMPREHENSIVE AND RELIABLE RANGE FOR EVERY POWER REQUIREMENT
Reliable, compact, user-friendly and versatile, the International
Spec Series generators are built to offer dependable power for all
applications (simple to complex), including healthcare, data centres,
airports and more.
These diesel generators are available in a wide range of power
outputs, from 6 kVA to 830 kVA, and can be customized to your
specific needs.
They are compatible with a variety of additional options and
accessories that are offered to further enhance performance and
deliver the best user experience.
KOHLER DECISION-MAKER® CONTROLSAvailable with a variety of controls – basic, advanced and paralleling, dedicated to generator set applications for optimal performance
CIRCUIT BREAKEROffers protection and maintenance of generator set
INTEGRATED FUEL-TANKIntegrated with generator skid that provides plug-and-play mode for quick on-site set up
OPTIONS AND ACCESSORIESImproved alternators, heavy-duty air cleaners, enclosures, fuel tanks, block heaters, multiple circuit breakers, heat-hand protection (CE)^ and more (Refer to page 14 for more information)
^ For selected models only. Please check with your sales representative on availability
4
1
2
3
INTERNATIONAL SPEC SERIESINDUSTRIAL DIESEL GENERATORS
SPEC YOUR JOB AT KOHLERPOWER.COM.SG 5
15-03517_IntlSpecA4.indd 5 3/2/16 11:19 am
KK SERIES
THREE-PHASE SPECIFICATIONS - Open Version
Specifications, 50 Hz, 230-400 V Specifications, 60 Hz, 277-480 V General Specifications
Generator Set
Model(1)
kVA Fuel Consumption at 3/4 Load,
L/h
Generator Set
Model(2)
kWe Fuel Consumption at 3/4 Load,
L/h
Engine Open Version(5)
Prime Power(3)
Standby Power(4)
Prime Power(3)
Standby Power(4) Engine Type Cyl CC, L Dimensions,
L x W x H, mWeight,
kg(6)Fuel
Tank, L
KK16H - 16 3.6 - - - - KDW1003-H 3 1.0 1.41 x 0.72 x 1.02 310 50
KK21H - 21 4.9 - - - - KDW1404-H 4 1.4 1.41 x 0.72 x 1.02 350 50
KK28H 28 22.4 7.5 - - - - KDW1603-H 3 1.7 1.70 x 0.90 x 1.12 500 100
KK9 8.1 8.9 1.9 KK9U 7.6 8.4 2.3 KDW1003 3 1.0 1.22 x 0.70 x 0.92 290 50
KK12 10.9 12 2.5 KK12U 10.5 11.6 2.9 KDW1404 4 1.4 1.41 x 0.72 x 1.02 340 50
KK16 15 16.5 3.7 KK16U 14.5 16 4.5 KDW1603 3 1.7 1.41 x 0.72 x 1.02 410 50
KK22 19.5 21.5 3.5 KK20U 18.2 20 4.1 KDI1903M 3 1.9 1.41 x 0.72 x 1.08 490 50
KK27 24.1 26.5 4.7 KK25U 23 25 5.5 KDI2504M 4 2.5 1.41 x 0.72 x 1.08 540 50
KK33 30 33 5.9 - - - - KDI2504TM-30 4 2.5 1.70 x 0.90 x 1.26 629 100
KK44 40 44 7.5 - - - - KDI2504TM-40 4 2.5 1.70 x 0.90 x 1.26 690 100
SINGLE-PHASE SPECIFICATIONS - Open Version
Specifications, 50 Hz, 230 V Specifications, 60 Hz, 240 V General Specifications
Generator Set
Model(1)
kVA Fuel Consumption at 3/4 Load,
L/h
Generator Set
Model(2)
kWe Fuel Consumption at 3/4 Load,
L/h
Engine Open Version(5)
Prime Power(3)
Standby Power(4)
Prime Power(3)
Standby Power(4) Engine Type Cyl CC, L Dimensions,
L x W x H, mWeight,
kg(6)Fuel
Tank, L
- - - - KK9UM 8 8.8 2.3 KDW1003 3 1.0 1.41 x 0.72 x 1.02 330 50
KK10M 9 9.9 2.5 KK12UM 10.9 12 2.9 KDW1404 4 1.4 1.41 x 0.72 x 1.02 350 50
KK12M 10.7 11.8 3.7 KK16UM 14.5 16 4.5 KDW1603 3 1.7 1.41 x 0.72 x 1.02 440 50
KK17M 15.6 17.2 3.5 KK20UM 18.2 20 4.1 KDI1903M 3 1.9 1.41 x 0.72 x 1.08 530 50
(1) Also available in the following voltages: 240/415 V, 220/380 V, 127/220 V, 115/220 V. (2) Also available in the following voltages: 254/440 V, 127/220 V, 120/208 V.(3) Prime power in direct current for an unlimited number of annual operating hours in variable load applications, in accordance with IS08528-1, a 10% overload capacity is
available for a period of 1 hour every 12-hour period of operation, in accordance with IS03046-1.(4) Emergency standby power available for supplying emergency power in variable load applications in accordance with IS08528-1, no overload available for this service.(5) The dimensions and weights apply to an open generator set without options.(6) Dry weight, without fuel.
Open Version - KK16U Open Version - KK27
6
15-03517_IntlSpecA4.indd 6 3/2/16 11:19 am
THREE-PHASE SPECIFICATIONS - Soundproofed Version
Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz
50 Hz 60 Hz Type Fuel Tank, L
Dimensions, L x W x H, m
Weight, kg
Fuel Tank, L
50 Hz, h Maximum Run Time
60 Hz, h Maximum Run Time
dB(A) @ 1m
dB(A) @ 7m
dB(A) @ 1m
dB(A) @ 7m
KK16H - M126 50 1.75 x 0.78 x 1.23 480 93 25.6 - 79 66 - -
KK21H - M126 50 1.75 x 0.78 x 1.23 520 93 19.0 - 80 67 - -
KK28H - M127 100 2.08 x 0.96 x 0.75 750 230 30.7 - 83 71 - -
KK9 KK9U M125 50 1.48 x 0.76 x 1.03 390 - - - 67 54 74 64
KK12 KK12U M126 50 1.75 x 0.78 x 1.23 510 93 36.8 31.7 67 54 74 64
KK16 KK16U M126 50 1.75 x 0.78 x 1.23 580 93 25.1 20.7 74 61 79 69
KK22 KK20U M126 50 1.75 x 0.78 x 1.23 660 93 26.6 22.5 71 58 77 67
KK27 KK25U M126 50 1.75 x 0.78 x 1.23 710 93 19.8 16.7 76 64 78 68
KK33 - M127 100 2.08 x 0.96 x 0.75 883 230 39.0 - 75 63 - -
KK44 - M127 100 2.08 x 0.96 x 0.75 944 230 30.7 - 76 64 - -
SINGLE-PHASE SPECIFICATIONS - Soundproofed Version
Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz
50 Hz 60 Hz Type Fuel Tank, L
Dimensions, L x W x H, m
Weight, kg
Fuel Tank, L
50 Hz, h Maximum Run Time
60 Hz, h Maximum Run Time
dB(A) @ 1m
dB(A) @ 7m
dB(A) @ 1m
dB(A) @ 7m
- KK9UM M126 50 1.75 x 0.78 x 1.23 500 93 - 40.4 - - 74 64
KK10M KK12UM M126 50 1.75 x 0.78 x 1.23 520 93 36.8 31.7 67 54 74 64
KK12M KK16UM M126 50 1.75 x 0.78 x 1.23 610 93 25.1 20.7 74 61 79 69
KK17M KK20UM M126 50 1.75 x 0.78 x 1.23 700 93 26.6 22.7 71 58 77 67
COMPACT POWERThe performances offered by KOHLER Diesel KDI engines ensure our generator sets boost a remarkable ratio of power to size. This means they can be made more compact, thereby reducing transport and storage costs. With optimized combustion, both the fuel consumption and pollutant levels are particularly low.
Soundproofed Version - KK9Soundproofed Version - KK27
9-44 kVA 8-25 kW
SPEC YOUR JOB AT KOHLERPOWER.COM.SG 7
15-03517_IntlSpecA4.indd 7 3/2/16 11:19 am
KM SERIES
THREE-PHASE SPECIFICATIONS - Open Version
Specifications, 50 Hz, 230-400 V Specifications, 60 Hz, 277-480 V General Specifications
Generator Set
Model(1)
kVA Fuel Consumption at 3/4 Load,
L/h
Generator Set
Model(2)
kWe Fuel Consumption at 3/4 Load,
L/h
Engine Open Version(5)
Prime Power(3)
Standby Power(4)
Prime Power(3)
Standby Power(4) Engine Type Cyl CC, L Dimensions,
L x W x H, mWeight,
kg(6)Fuel
Tank, L
KM9H - 9 2.6 - - - - L2E-SDH 2 0.6 1.22 x 0.70 x 0.92 240 50
KM12H - 12 4.2 - - - - L3E-SDH 3 1.0 1.22 x 0.70 x 0.92 260 50
KM8 6.8 7.5 1.7 - - - - L3E-SD 3 1.0 1.22 x 0.70 x 0.92 280 50
KM12 10.5 11.5 2.5 KM11U 10.2 11.2 3.2 S3L2-SD 3 1.3 1.41 x 0.72 x 1.05 387 50
KM16 14.5 16 3.4 KM16U 14.5 16 4.2 S4L2-SD 4 1.8 1.41 x 0.72 x 1.05 406 50
KM22 20 22 4.7 KM20U 18.2 20 5.6 S4Q2-SD 4 2.5 1.70 x 0.90 x 1.12 549 100
KM33 30 33 6.0 KM30U 27 30 8.2 S4S-SD 4 3.3 1.70 x 0.90 x 1.14 670 100
KM44 40 44 7.3 KM40U 36 40 8.7 S4S-DT 4 3.3 1.70 x 0.90 x 1.22 680 100
SINGLE-PHASE SPECIFICATIONS - Open Version
Specifications, 50 Hz, 230 V Specifications, 60 Hz, 240 V General Specifications
Generator Set
Model(1)
kVA Fuel Consumption at 3/4 Load,
L/h
Generator Set
Model(2)
kWe Fuel Consumption at 3/4 Load,
L/h
Engine Open Version(5)
Prime Power(3)
Standby Power(4)
Prime Power(3)
Standby Power(4) Engine Type Cyl CC, L Dimensions,
L x W x H, mWeight,
kg(6)Fuel
Tank, L
KM8HM - 7.5 2.6 - - - - L2E-SDH 2 0.6 1.22 x 0.70 x 0.92 220 50
KM11HM - 10.5 4.2 - - - - L3E-SDH 3 1.0 1.22 x 0.70 x 0.92 280 50
KM6M 5 5.5 1.7 KM8UM 6.8 7.5 2.2 L3E-SD 3 1.0 1.22 x 0.70 x 0.92 280 50
KM9M 7.8 8.6 2.5 KM11UM 9.1 10 3.2 S3L2-SD 3 1.3 1.41 x 0.72 x 1.05 396/417 50
KM12M 10.9 12 3.4 KM16UM 13.6 15 4.2 S4L2-SD 4 1.8 1.41 x 0.72 x 1.05 406 50
KM17M 15.5 17 4.7 KM20UM 18.2 20 5.6 S4Q2-SD 4 2.5 1.70 x 0.90 x 1.12 590 100
KM25M 22.7 25 6.0 KM30UM 22 24 8.2 S4S-SD 4 3.3 1.70 x 0.90 x 1.14 710 100
- - - - KM40UM 36 40 8.7 S4S-DT 4 3.3 1.70 x 0.90 x 1.22 656 100
(1) Also available in the following voltages: 240/415 V, 220/380 V, 127/220 V, 115/220 V.(2) Also available in the following voltages: 254/440 V, 127/220 V, 120/208 V.(3) Prime power in direct current for an unlimited number of annual operating hours in variable load applications, in accordance with IS08528-1, a 10% overload capacity is
available for a period of 1 hour every 12-hour period of operation, in accordance with IS03046-1.(4) Emergency standby power available for supplying emergency power in variable load applications in accordance with IS08528-1, no overload available for this service.(5) The dimensions and weights apply to an open generator set without options.(6) Dry weight, without fuel.
Open Version - KM20 Open Version - KM44
8
15-03517_IntlSpecA4.indd 8 3/2/16 11:19 am
THREE-PHASE SPECIFICATIONS - Soundproofed Version
Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz
50 Hz 60 Hz Type Fuel Tank, L
Dimensions, L x W x H, m
Weight, kg
Fuel Tank, L
50 Hz, h Maximum Run Time
60 Hz, h Maximum Run Time
dB(A) @ 1m
dB(A) @ 7m
dB(A) @ 1m
dB(A) @ 7m
KM9H - M125 50 1.48 x 0.76 x 1.03 360 93 35.8 - 79 65 - -
KM12H - M125 50 1.48 x 0.76 x 1.03 380 93 22.1 - 80 66 - -
KM8 - M125 50 1.48 x 0.76 x 1.03 390 ConsultFactory
ConsultFactory - 71 57 - -
KM12 KM11U M126 50 1.75 x 0.78 x 1.23 530 93 37.2 29.1 71 58 73 63
KM16 KM16U M126 50 1.75 x 0.78 x 1.23 554 93 27.4 22.1 72 72 74 64
KM22 KM20U M127 100 2.08 x 0.96 x 1.42 780 230 48.9 41.1 70 58 75 65
KM33 KM30U M127 100 2.08 x 0.96 x 1.42 900 230 38.3 28.0 74 62 76 66
KM44 KM40U M127 100 2.08 x 0.96 x 1.42 920 230 31.5 26.4 74 62 79 69
SINGLE-PHASE SPECIFICATIONS - Soundproofed Version
Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz
50 Hz 60 Hz Type Fuel Tank, L
Dimensions, L x W x H, m
Weight, kg
Fuel Tank, L
50 Hz, h Maximum Run Time
60 Hz, h Maximum Run Time
dB(A) @ 1m
dB(A) @ 7m
dB(A) @ 1m
dB(A) @ 7m
KM8HM - M125 50 1.48 x 0.76 x 1.03 340 93 35.8 - 79 65 - -
KM11HM - M125 50 1.48 x 0.76 x 1.03 400 93 22.1 - 82 68 - -
KM6M KM8UM M125 50 1.48 x 0.76 x 1.03 390 ConsultFactory
ConsultFactory
ConsultFactory 70 57 78 68
KM9M KM11UM M126 50 1.75 x 0.78 x 1.23 544/565 93 37.2 29.1 71 58 73 63
KM12M KM16UM M126 50 1.75 x 0.78 x 1.23 630 93 27.4 22.1 72 59 75 65
KM17M KM20UM M127 100 2.08 x 0.96 x 1.42 820 230 48.9 41.1 70 58 75 65
KM25M KM30UM M127 100 2.08 x 0.96 x 1.42 940 230 38.3 28.0 74 62 76 66
- KM40UM M127 100 2.08 x 0.96 x 1.42 886 230 - 26.4 - - 79 69
6-44 kVA 10-40 kW
OPTION DETAILSKohler offers an optional double wall base frame that allows prolonged run time. With its double wall, the environment is protected against any possible fuel leak. It is the ideal option for use in isolated areas.
Soundproofed Version - KM33Soundproofed Version - KM9H
SPEC YOUR JOB AT KOHLERPOWER.COM.SG 9
15-03517_IntlSpecA4.indd 9 3/2/16 11:19 am
KD SERIES
THREE-PHASE SPECIFICATIONS - Open Version
Specifications, 50 Hz, 230-400 V Specifications, 60 Hz, 277-480 V General Specifications
Generator Set
Model(1)
kVA Fuel Consumption at 3/4 Load,
L/h
Generator Set
Model(2)
kWe Fuel Consumption at 3/4 Load,
L/h
Engine Open Version(5)
Prime Power(3)
Standby Power(4)
Prime Power(3)
Standby Power(4) Engine Type Cyl CC, L Dimensions,
L x W x H, mWeight,
kg(6)Fuel
Tank, L
KD22 20 22 5 KD20U 18.2 20 6.5 3029DFS29 3 2.9 1.70 x 0.90 x 1.22 750/709 100
KD33 30 33 5 KD30U 25 28 6.5 3029DFS29 3 2.9 1.70 x 0.90 x 1.22 750 100
KD44 40 44 7.5 KD40U 36 40 8.7 3029TFS29 3 2.9 1.70 x 0.90 x 1.22 820 100
KD66 60 66 12 KD60U 55 60 14.5 4045TF120 4 4.5 1.87 x 0.99 x 1.36 995 180
KD77 70 77 12 KD70U 64 70 14.5 4045TF120 4 4.5 1.87 x 0.99 x 1.36 1128/1070 180
KD88 80 88 14 KD80U 73 80 16 4045TF220 4 4.5 1.87 x 0.99 x 1.36 1088/1070 180
KD110 100 110 16.5 KD100U 91 100 19 4045HF120 4 4.5 1.95 x 1.08 x 1.33 1187 190
KD130 120 132 18.5 KD120U 106 117 24 6068TF220 6 6.7 2.37 x 1.11 x 1.48 1498 340
KD165 150 165 25 KD150U 137 150 29 6068HF120-153 6 6.7 2.37 x 1.11 x 1.48 1578 340
KD200 182 200 31.3 KD175U 159 175 36.1 6068HF120-183 6 6.7 2.37 x 1.11 x 1.48 1730 340
- - - - KD200U 182 200 36.9 6068HF475 6 6.7 2.40 x 1.11 x 1.48 1790 340
KD220C2 200 220 34 - - - - 6068HFS77 6 6.7 2.40 x 1.11 x 1.48 1790 340
KD250 227 250 35.9 - - - - 6068HFS55-228 6 6.7 2.40 x 1.11 x 1.54 1800 340
SINGLE-PHASE SPECIFICATIONS - Open Version
Specifications, 50 Hz, 230 V Specifications, 60 Hz, 240 V General Specifications
Generator Set
Model(1)
kVA Fuel Consumption at 3/4 Load,
L/h
Generator Set
Model(2)
kWe Fuel Consumption at 3/4 Load,
L/h
Engine Open Version(5)
Prime Power(3)
Standby Power(4)
Prime Power(3)
Standby Power(4) Engine Type Cyl CC, L Dimensions,
L x W x H, mWeight,
kg(6)Fuel
Tank, L
- - - - KD20UM 18.2 20 6.5 3029DFS29 3 2.9 1.70 x 0.90 x 1.22 750 100
- - - - KD30UM 20.4 22.4 6.5 3029DFS29 3 2.9 1.70 x 0.90 x 1.22 800 100
- - - - KD40UM 36 40 8.7 3029TFS29 3 2.9 1.70 x 0.90 x 1.22 786 100
- - - - KD60UM 55 60 14.5 4045TF120 4 4.5 1.87 x 0.99 x 1.36 1187 190
(1) Also available in the following voltages: 240/415 V, 220/380 V, 127/220 V, 115/220 V.(2) Also available in the following voltages: 254/440 V, 127/220 V, 120/208 V.(3) Prime power in direct current for an unlimited number of annual operating hours in variable load applications, in accordance with IS08528-1, a 10% overload capacity is
available for a period of 1 hour every 12-hour period of operation, in accordance with IS03046-1.(4) Emergency standby power available for supplying emergency power in variable load applications in accordance with IS08528-1, no overload available for this service.(5) The dimensions and weights apply to an open generator set without options.(6) Dry weight, without fuel.
Open Version - KD88 Open Version - KD110
10
15-03517_IntlSpecA4.indd 10 3/2/16 11:19 am
THREE-PHASE SPECIFICATIONS - Soundproofed Version
Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame
Enclosures with 48-hour
Tank
Sound Levels, 50 Hz
Sound Levels, 60 Hz
50 Hz 60 Hz Type Fuel Tank, L
Dimensions, L x W x H, m
Weight, kg
Fuel Tank, L
50 Hz, h Maximum Run Time
60 Hz, h Maximum Run Time
Tank, L dB(A) @ 1m
dB(A) @ 7m
dB(A) @ 1m
dB(A) @ 7m
KD22 KD20U M127 100 2.08 x 0.96 x 1.42 980/930 230 46.0 35.4 420 75 62 78 68
KD33 KD30U M127 100 2.08 x 0.96 x 1.42 980 230 46.0 35.4 420 74 62 78 68
KD44 KD40U M127 100 2.08 x 0.96 x 1.42 1040 230 30.7 26.4 420 74 62 77 67
KD66 KD60U M128 180 2.30 x 1.06 x 1.68 1405 390 32.5 26.9 700 73 61 77 67
KD77 KD70U M128 180 2.30 x 1.06 x 1.68 1548/1476 390 32.5 26.9 700 74 62 77 67
KD88 KD80U M128 180 2.30 x 1.06 x 1.68 1508/1476 390 27.9 24.4 700 76 64 83 73
KD110 KD100U M129 190 2.55 x 1.15 x 1.68 1587 505 30.6 26.6 825 78 66 80 70
KD130 KD120U M226 340 3.51 x 1.20 x 1.83 2088 868 46.9 36.2 1630 75 64 80 69
KD165 KD150U M226 340 3.51 x 1.20 x 1.83 2168 868 34.7 29.9 1630 75 64 80 69
KD200 KD175U M226 340 3.51 x 1.20 x 1.83 2320 868 27.7 24.0 1630 76 65 80 69
- KD200U M226 340 3.51 x 1.20 x 1.83 2390 868 - 23.5 1630 - - 80 70
KD220C2 - M226 340 3.51 x 1.20 x 1.83 2390 868 25.5 - 1630 77 66 - -
KD250 - M226 340 3.51 x 1.20 x 1.83 2400 868 24.2 - 1630 82 71 - -
SINGLE-PHASE SPECIFICATIONS - Soundproofed Version
Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz
50 Hz 60 Hz Type Fuel Tank, L
Dimensions, L x W x H, m
Weight, kg
Fuel Tank, L
50 Hz, h Maximum Run Time
60 Hz, h Maximum Run Time
dB(A) @ 1m
dB(A) @ 7m
dB(A) @ 1m
dB(A) @ 7m
- KD20UM M127 100 2.08 x 0.96 x 1.42 980 230 - 35.4 - - 78 68
- KD30UM M127 100 2.08 x 0.96 x 1.42 1020 230 - 35.4 - - 78 68
- KD40UM M127 100 2.08 x 0.96 x 1.42 1016 230 - 26.4 - - 77 67
- KD60UM M129 190 2.55 x 1.15 x 1.68 1577 390 - 26.9 - - 77 67
OPTION DETAILSKohler offers an optional base frame with 48-hour tank. For maximum run time, opt for the double wall base frame with a large capacity integrated fuel tank that is idea for isolated areas. This option combines the need for autonomy with security, making it possible for all of the generator set’s fluids to be held.
Soundproofed Version - KD200Soundproofed Version - KD100U
with optional 48-hour tank
20-250 kVA 18-200 kW
SPEC YOUR JOB AT KOHLERPOWER.COM.SG 11
15-03517_IntlSpecA4.indd 11 3/2/16 11:19 am
KV SERIES
THREE-PHASE SPECIFICATIONS - Open Version
Specifications, 50 Hz, 230-400 V Specifications, 60 Hz, 277-480 V General Specifications
Generator Set
Model(1)
kVA Fuel Consumption at 3/4 Load,
L/h
Generator Set
Model(2)
kWe Fuel Consumption at 3/4 Load,
L/h
Engine Open Version(5)
Prime Power(3)
Standby Power(4)
Prime Power(3)
Standby Power(4) Engine Type Cyl CC, L Dimensions,
L x W x H, mWeight,
kg(6)Fuel
Tank, L
- - - - KV250U 217 239 45.7 TAD734GE 6 7.2 2.90 x 1.30 x 1.59 2260 390
KV275C2 250 275 42.6 - - - - TAD734GE 6 7.2 2.90 x 1.30 x 1.59 2200 390
KV350C2 318 350 48 KV300U 273 300 54 TAD1341GE 6 12.8 3.16 x 1.34 x 1.76 3110 470
KV400C2 352 387 58 KV350U 319 350 69 TAD1342GE 6 12.8 3.16 x 1.34 x 1.76 3060 470
KV440C2 400 440 63.3 KV400U 364 400 72.4 TAD1344GE 6 12.8 3.16 x 1.34 x 1.81 3110 470
KV500C2 455 500 69.2 - - - - TAD1345GE 6 12.8 3.16 x 1.34 x 1.81 3250 470
KV550C2 500 550 75.4 KV500UC2 455 500 88.8 TAD1641GE 6 16.1 3.47 x 1.50 x 2.04 3620 500
- - - - KV550UC2 500 550 97.1 TAD1642GE 6 16.1 3.47 x 1.63 x 2.10 3650 610
KV650C2 591 650 85.2 - - - - TAD1642GE 6 16.1 3.47 x 1.63 x 2.10 3780 610
KV700C2 650 700 94.5 KV600UC2 545 600 105.7 TWD1643GE 6 12.8 3.47 x 1.63 x 2.05 4020 610
Open Version - KV500C2 Soundproofed Version - KV440C2
250-700 kVA 217-600 kW
THREE-PHASE SPECIFICATIONS - Soundproofed Version
Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz
50 Hz 60 Hz Type Fuel Tank, L
Dimensions, L x W x H, m
Weight, kg
Fuel Tank, L
50 Hz, h Maximum Run Time
60 Hz, h Maximum Run Time
dB(A) @ 1m
dB(A) @ 7m
dB(A) @ 1m
dB(A) @ 7m
- KV250U M227 390 4.00 x 1.38 x 2.15 3190 950 - 20.8 - - 84 74
KV275C2 - M227 390 4.00 x 1.38 x 2.15 3130 950 22.3 - 78 67 - -
KV350C2 KV300U M228 470 4.48 x 1.41 x 2.43 3670 1368 28.5 25.3 77 67 85 75
KV400C2 KV350U M228 470 4.48 x 1.41 x 2.43 4170 1368 23.6 19.8 77 67 86 76
KV440C2 KV400U M229 500 5.03 x 1.56 x 2.44 4080 1368 21.6 18.9 78 68 89 79
KV500C2 - M228 470 4.48 x 1.41 x 2.43 4360 1368 19.8 - 78 68 - -
KV550C2 KV500UC2 M229 500 5.03 x 1.56 x 2.44 4870 1770 23.5 19.9 76 66 85 75
- KV550UC2 M230 610 5.03 x 1.69 x 2.66 5146 1950 - 20.1 - - 92 82
KV650C2 - M230 610 5.03 x 1.69 x 2.66 5300 1950 22.9 - 80 70 - -
KV700C2 KV600UC2 M230 610 5.03 x 1.69 x 2.66 5550 1950 20.6 18.4 85 75 89 79
(1) Also available in the following voltages: 240/415 V, 220/380 V, 127/220 V, 115/220 V.(2) Also available in the following voltages: 254/440 V, 127/220 V, 120/208 V.(3) Prime power in direct current for an unlimited number of annual operating hours in variable load applications, in accordance with IS08528-1, a 10% overload capacity is
available for a period of 1 hour every 12-hour period of operation, in accordance with IS03046-1.(4) Emergency standby power available for supplying emergency power in variable load applications in accordance with IS08528-1, no overload available for this service.(5) The dimensions and weights apply to an open generator set without options.(6) Dry weight, without fuel.
12
15-03517_IntlSpecA4.indd 12 3/2/16 11:19 am
KH SERIES
THREE-PHASE SPECIFICATIONS - Open Version
Specifications, 50 Hz, 230-400 V Specifications, 60 Hz, 277-480 V General Specifications
Generator Set
Model(1)
kVA Fuel Consumption at 3/4 Load,
L/h
Generator Set
Model(2)
kWe Fuel Consumption at 3/4 Load,
L/h
Engine Open Version(5)
Prime Power(3)
Standby Power(4)
Prime Power(3)
Standby Power(4) Engine Type Cyl CC, L Dimensions,
L x W x H, mWeight,
kg(6)Fuel
Tank, L
KH275 250 275 43.6 - - - - P126TI 6 11.1 2.90 x 1.30 x 1.67 2340 390
KH300 273 300 43.6 KH250U 227 250 52.3 P126TI 6 11.1 2.90 x 1.30 x 1.67 2410 390
KH330 300 330 47.0 KH300U 273 300 56.0 P126TI-II 6 11.1 3.16 x 1.34 x 1.59 2570 470
KH440 400 440 65.1 KH400U 364 400 74.7 P158LE 8 14.6 3.47 x 1.50 x 1.83 2910 500
KH550 500 550 83.4 KH500U 449 494 92.9 DP158LDF 8 14.6 3.47 x 1.50 x 1.82 3220 500
KH630 573 630 94.2 KH550U 500 550 106.6 DP180LA 10 18.3 3.47 x 1.53 x 2.16/1.97 3700/3465 610
KH700 631 694 103.8 KH600U 542 596 114.2 DP180LB 10 18.3 3.47 x 1.53 x 2.16 3700 610
KH830 750 825 119.1 KH750U 682 750 134.4 DP222LC 12 21.9 3.47 x 1.53 x 2.85 4080 610
Soundproofed Version - KH600UOpen Version - KH440
250-830 kVA 227-750 kW
THREE-PHASE SPECIFICATIONS - Soundproofed Version
Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz
50 Hz 60 Hz Type Fuel Tank, L
Dimensions, L x W x H, m
Weight, kg
Fuel Tank, L
50 Hz, h Maximum Run Time
60 Hz, h Maximum Run Time
dB(A) @ 1m
dB(A) @ 7m
dB(A) @ 1m
dB(A) @ 7m
KH275 - M227 390 4.00 x 1.38 x 2.15 3190 950 21.8 - 83 73 - -
KH300 KH250U M227 390 4.00 x 1.38 x 2.15 3260 950 21.8 18.2 85 75 92 78
KH330 KH300U M228 470 4.48 x 1.41 x 2.43 3670 1368 29.1 24.4 81 71 85 75
KH440 KH400U M229 500 5.03 x 1.56 x 2.44 4090 1770 27.2 23.7 85 75 89 79
KH550 KH500U M229 500 5.03 x 1.56 x 2.44 4262 1770 21.2 19.0 84 74 90 80
KH630 KH550U M230 610 5.03 x 1.69 x 2.66 5381/5146 1950 20.7 18.3 88 78 92 82
KH700 KH600U M230 610 5.03 x 1.69 x 2.66 5381 1950 18.8 17.0 88 78 92 82
KH830 KH750U M230 610 5.03 x 1.69 x 2.66 5670 1950 16.4 14.5 88 78 88 78
(1) Also available in the following voltages: 240/415 V, 220/380 V, 127/220 V, 115/220 V.(2) Also available in the following voltages: 254/440 V, 127/220 V, 120/208 V.(3) Prime power in direct current for an unlimited number of annual operating hours in variable load applications, in accordance with IS08528-1, a 10% overload capacity isavailable for a period of 1 hour every 12-hour period of operation, in accordance with IS03046-1.(4) Emergency standby power available for supplying emergency power in variable load applications in accordance with IS08528-1, no overload available for this service.(5) The dimensions and weights apply to an open generator set without options.(6) Dry weight, without fuel.
SPEC YOUR JOB AT KOHLERPOWER.COM.SG 13
15-03517_IntlSpecA4.indd 13 3/2/16 11:19 am
GENERATOR SETS
MODULAR GENERATOR SETS, AN ADAPTED RESPONSE
For each of its generator sets, Kohler offers a large range of options to facilitate maintenance operations, enhance user
safety and provide solutions for specific requirements or unusual environments.
OPTION SPECIFICATIONS BY RANGE
KK Series KM Series KD Series KV Series KH Series
Protection of hot parts CEL02 CEL02 CEL02 CEL02 CEL02
Diesel separator pre-filter FD05 FD05 • • FD05
Battery isolating switch EN16 EN16 EN16 EN16 EN16
Automatic pack CA303/CM403 CA303/CM403 CA303/CM403 CM403/CM404 CM404
Electronic control EN01 EN01 EN01 • •
Automatic filling kit FD08(1) FD08(1) FD08(1) FD08(1) FD08(1)
Drainage pump EN04 EN04 EN04 • EN04
Analog measurements display CA307/CM407 CA307/CM407 CA307/CM407 • •
Oversized alternator X AO001B(2) AO001B(3) AO001B(4) AO001B(5)
Air discharge duct CN03 CN03 CN03 CN03 CN03
9dB(A) silencer in open version •(6) •(6) •(6) •(6) •(6)
High run time, double wall base frame FD02* FD02* FD02 FD02 FD02
Base frame with 48-hour tank X X FD03 X X
40dB(A) silencer EN09 EN09 EN09 EN09 EN09
• Standard X: Not available. CEL02: option code* for all generator sets except for M125 enclosures(1) Not possible on 48-hour and double wall base frame(2) Option not available for 3000 rpm and KM30UM, KM40U, KM40UM and KM44 generator sets(3) Option not available for KD20UM, KD30UM, KD40U, KD44, KD70U, KD80U and KD88 generator sets and on the soundproofed version of the KD220C2(4) Option not available on the soundproofed versions of KV600UC2 and KV700C2 sets(5) Option not available for the KH700 and on the soundproofed versions of the KH500U, KH550 and KH600U sets(6) 29 dB(A) and 40 dB(A) silencer available as an option
ANALOG MEASUREMENTS DISPLAY (CA307/CM407)This option enables the oil pressure and the water temperature to be displayed on the APM303 or DEC4000 screen. In some cases, this is on an additional display.
AIR DISCHARGE DUCT (EN12/EN08/EN09)Metal elbow-shaped box section which enables the air to be discharged from the top of the enclosure towards the front of the generator set.
BATTERY ISOLATING SWITCH (EN16)Battery isolator rotary handle for easy isolation of the battery during generator set storage.
1 2 3
2 31
14
15-03517_IntlSpecA4.indd 14 3/2/16 11:19 am
PROTECTION FOR HOT PARTS (CEL02)Protective grille for hot parts (exhaust manifold) on the diesel engine and rotating parts. This option ensures the user's safety during maintenance operations.Mandatory option within the European community (European directive).
OVERSIZED ALTERNATOR (AO001B)For use under heavy electrical or climate constraints, this option allows greater operating flexibility for a better guarantee of performance.
DRAINAGE PUMP (EN04-EN05)Manual oil drainage pump for easier servicing of the generator set during maintenance operations. Standard option on enclosed generator sets.
SILENCER ON OPEN VERSIONFor "open" version generator sets, a choice of 3 noise reduction levels is available (9dB(A), 29dB(A), 40dB(A)), to meet the constraints of various installations.
AUTOMATIC PACK (EN20)This includes a preheating resistor and a battery charger. It is an engine preheating device which uses an electrical resistor. Preheating is self-adjusting up to 200 KVA and thermostat-controlled for outputs above this. This option is ideal for generator sets used as back-up. It allows the coolant to be maintained at a temperature of 40°C to facilitate emergency start-up and save time when
commissioning the generator set.
DIESEL SEPARATOR PRE-FILTER (FD05)This is a pre-filter enabling water contained in diesel to be removed, thereby improving the engine's protection.
FILTER WITH INTERCHANGEABLE CARTRIDGE (EN02)Dry air filters with removable and interchangeable cartridges for dusty environments which can be removed and cleaned with blown air, if required.This option is required when the generator set is used in dusty environments.
AUTOMATIC FILLING KIT (FD08)This is an automatic kit for filling the tank from an external storage tank.It includes:- An electric pump with automatic control governed by a gauge with level
contacts- A manual back-up pump
Extended use is possible without having to top up the diesel. This is particularly well suited for use in isolated areas.
ELECTRONIC CONTROL (EN01)Electronic speed regulator with control unit enabling precise control of speed, and therefore the frequency, to +/- 1%. This regulator is factory fitted as standard on some engines. This option allows the quality of the signal to be improved for better operation of sensitive equipment.
4
4
5
5
6
6
7
7
8
89
9
STANDARD FEATURES AND OPTIONS
SPEC YOUR JOB AT KOHLERPOWER.COM.SG 15
15-03517_IntlSpecA4.indd 15 3/2/16 11:19 am
SOUND ENCLOSURESKEEPING THE NOISE IN.
Built for reliability with self-diagnostic features, Kohler generator sets
come equipped with sound enclosures and integrated fuel tanks.
GENERAL SPECIFICATIONS
• Assembled soundproofing enclosures
• Kohler cream beige standard colour
• Rust-resistance : Electro-galvanized steel panels coated with
heat-hardening powder based on polyester resin as a form of
rust protection.
• High corrosion resistance for enclosure parts and fixtures
• Acoustic sound treatment : Soundproofing and fire-retardant
foam between 20-50mm thickness
• Silent operation: High priority on noise reduction and conforms
to 2000/14/EC noise emission standards
• Modularity: Modular design without complex installation;
maintenance and re-ordering of components now made
simpler and hassle-free
• Integrated fuel tank in generator skid
• Power circuit break
PLUG-AND-PLAY − No need for complex installation and
messy cabling− Shipped ready-to-use, ensuring seamless
and efficient integration into your power system
MOBILITY − Availability of lifting and handling points
to facilitate easy transportation− Minimal effort in installation required− Rapid deployment when rendering
back-up power
SILENT OPERATION − Sound-attenuating enclosures that are
quiet and rigorously tested
OUTDOOR INSTALLATION − Allow for more productive use of space
with outdoor installation− Cost-savings
16
15-03517_IntlSpecA4.indd 16 3/2/16 11:19 am
STANDARD FEATURES AND OPTIONS
This chart shows option codes (examples: Sim, EN04, TR31, etc.). Feature codes refer to specific option descriptions
but are not part numbers for ordering purposes. Contact your authorized distributor for ordering options for a given
generator set.
Enclosures
M125 M126 M127, M128, M129 M226 M227, M228,
M229 M230
General Specifications
Assembled soundproofing enclosure Sim Sim Sim Sim Sim Sim
Non-assembled soundproofing enclosure (supplied as a kit)(1) N/A Sik Sik N/A N/A N/A
Kohler cream beige standard color Standard Standard Standard Standard Standard Standard
Special color (lead time 8 weeks) CN08 CN08 CN08 CN08 CN08 CN08
Electrogalvanized steel panels before paint application protected by a rust-resistant polyester powder coat Standard Standard Standard Standard Standard Standard
Dichromate galvanized hardware and stainless steel rivets, polyamide or anodized aluminum alloy hinges, seals provided by flexible joints between the body work components
Standard Standard Standard Standard Standard Standard
Soundproofing foam between 20-50 mm thick Standard Standard Standard Standard Standard Standard
Bulk tank on day service tank N/A N/A N/A FD04 FD04 FD04
Fluid recovery tank Standard Standard Standard N/A N/A N/A
High containment double wall chassis N/A FD02 FD02 FD02 FD02 FD02
Safety
Lockable doors with a unique key Standard Standard Standard Standard Standard Standard
Lockable control unit porthole Standard Standard Standard Standard Standard Standard
Emergency stop button installed on outside of enclosure Standard Standard Standard Standard Standard Standard
Access to diesel, oil and battery behind lockable doors Standard Standard Standard Standard Standard Standard
Protective guard for rotating parts Standard Standard Standard Standard Standard Standard
Exhaust integrated into the enclosure Standard Standard Standard Standard Standard Standard
Horizontal exhaust discharge hood CN03 CN03 CN03 CN03 CN03 CN03
Remote connection terminal block for armored cables N/A CN06 CN06 CN06 CN06 N/A
Socket kit, 400-volt, 3-phase, plus neutral(2) CN04 CN04 CN04 N/A N/A N/A
Handling
Lifting ring (number of points) 1 1 1 1 2 2
Single base panel N/A N/A N/A CN05 CN05 CN05
Maintenance
Access doors on each side (number) 2+1 2+1 2+1 2+2 2+2 2+2
Oil drain pump EN04 EN04 EN04 EN04 EN04 EN06
Electric control unit accessible via a door Standard Standard Standard Standard Standard Standard
Trailers(3)
Road trailer with fixed drawbar and ball attachment TR1 0 TR1 0 N/A N/A N/A N/A
Road trailer with hinged drawbar and ring attachment, 68 × 42 mm TR11 TR11 TR11 TR11 N/A N/A
Pintle ring, 40 mm (DIN German) TR21 TR21 TR21 TR21 N/A N/A
Pintle ring, 76 mm TR25 TR25 TR25 TR25 N/A N/A
Ball (universal), 50 mm TR26 TR26 TR26 TR26 N/A N/A
Spare wheel kit TR31 TR31 TR31 TR31 N/A N/A
TR21 Available at no additional cost(1) This option requires special handling and installation(2) Requires different protection(3) Contact your authorized distributor for availability.N/A Not available
SPEC YOUR JOB AT KOHLERPOWER.COM.SG 17
15-03517_IntlSpecA4.indd 17 3/2/16 11:19 am
GENERATOR SET CONTROLS
Kohler offers a unique range of specific control units: APM303, DEC4000 and APM802. These control units offer a wide
range of possibilities, from simplified running to the option of managing the most complex coupling operations, and can
be adapted to suit every need.
APM303 DEC4000 APM802
KK Series • O X
KM Series • O X
KD Series • O X
KV Series X • O
KH Series X • O
COMPARISON OF THE 3 GENERATOR SET CONTROLS
SPECIFICATIONS APM303 DEC4000 APM802DISPLAY
Frequency • • •Phase to neutral voltages • • •Phase to phase voltages • • •
Currents • • •Active/reactive/apparent power • • •
Power factor • • •Battery voltage • • •Battery current X O OStart-up delay • • •
Fuel level • • •Oil pressure • • •
Coolant temperature • • •Oil temperature X O O
Total working hours counter • • •Partial working hours counter X • •
Total active/reactive energy meter • • •Genset speed • • •
FAULT INFORMATION (FAULT OR ALARM)Min/max alternator voltage • • •
Min/max alternator frequency • • •Min/max battery voltage • • •
Overload and/or short circuit • • •Active/reactive power return X • •
Oil pressure • • •Coolant temperature • • •
Speed too high • • •Speed too low • • •Low fuel level • • •
Emergency stop fault • • •Non-starting fault • • •
Charging alternator fault • • •Differential relay activation fault O • •
General alarm • • •General fault • • •Sound alarm O • •
SPECIFICATIONS APM303 DEC4000 APM802OPERATION
Power ON O • XManual generator set starting • • •
Automatic generator set starting • • •Generator set shut down • • •
Emergency stop • • •Navigation in colour touch-screen menu X X •
Navigation in menu using wheel X • XNavigation in menu using button • X X
Speed adjustment O O •Voltage adjustment O O •
Dual frequency X O ODelayed start programming X • •
Multilingual using pictograms • • XMultilingual text X • •
CONNECTIVITYEthernet port (website) X • •
RS485 (JBUS protocol) • • •Engine CAN Bus (J1939) O • •
USB port (config and software downloading) • • •COUPLING
Under load X O •Shut down X X •
Droop distribution of active and reactive power X O •Parallel line distribution of active and reactive power X X •
CAN Bus distribution of active/reactive power X X •Power plant wattmeter control X X •
Temporary coupling of Out/Return grid X O •Power plant coupling to grid (temporary, permanent, etc.) X X •
GeneralDownloading of a customized
configuration via USB port • • •
• Standard O Option X Not available
• Standard O Option X Not available
18
15-03517_IntlSpecA4.indd 18 3/2/16 11:19 am
APM303THE ESSENTIALS MADE SIMPLE.
The APM303 is a versatile unit equipped with a particularly intuitive LCD screen. It offers high-quality basic functions,
allowing easy and reliable operation of your generator set. This unit is mounted on a console on all generator sets designed
for LV industrial applications with and without source transfer switch.
FUNCTIONS • Manual and automatic mode (with auto start input)• Generator set protection and management• Electrical measurements, including power• Mechanical value measurements• Automatic voltage and frequency detection• Secure configuration on the APM303 or on PC
CONNECTIVITY• 2 configurable reports• RTU RS485 Modbus
• USB port
OPERATION CONDITIONS• Front of IP54 controller• Protection against humidity and dust with tropicalized varnish
*Advanced Power Management
MEASUREMENTS
LCD DISPLAY EXAMPLES
overview display
output
meters
current and voltage
mechanical values
log and alerts
Ergonomic, universal LCD screen
Alarm/fault report indicator
STOP/START/AUTO buttons and AUTO mode indicator light
Generator set operating light
Screen scroll buttons
SPEC YOUR JOB AT KOHLERPOWER.COM.SG 19
15-03517_IntlSpecA4.indd 19 3/2/16 11:19 am
DEC4000ERGONOMIC AND INTUITIVE.
ZONE 1: Operation mode (auto/manual/GS output, etc.)
ZONE 2: Display of functions via pictograms
ZONE 3: Display of mechanical and electrical values
and the associated measurements
ZONE 4: Operating messages and parameter settings
menu
ZONE 1
ZONE 4
ZONE 2
SCREEN
Screen with contrast which adjusts to all types of light.
Viewing and remote control functions with option to send an
e-mail, text message or fax in the event of an alarm or a fault
(optional).
FUNCTIONS
Compliance with numerous legal and regulatory requirements
(EC) Integrated diagnostic tool to guide the user when alarms
or faults appear Integrated maintenance monitoring (screen
display of planned maintenance procedures).
CONNECTIVITY
2 USB ports under sealed cover.
OPERATION CONDITIONS
Tropicalization of the electronic board to withstand conditions
of extreme humidity.
Display Screen composed of 4 zones:
Scrolling andvalidation wheel
Menu accessbutton
Generator set stop button
Generator set start button
Escape buttonSystem power ON
Fuse
ON/OFF key switch
Emergency stop button
2 USB ports under a sealed cover
Alarms Faults
Display screen
The KOHLER® DEC4000 Control Unit is straightforward and user-friendly, emphasizing on communication
(USB connections, PC connections, control software and remote operation).
ZONE 3
20
15-03517_IntlSpecA4.indd 20 3/2/16 11:19 am
The APM802 command/control system is specifically designed for operating and monitoring power plants for markets
including hospitals, data centres, banks, the oil and gas sector, IPP, rental and mining.
The Human Machine Interface (HMI), designed in collaboration with a company specialising in interface design, facilitates
operations with a large 100% touch screen. The pre-configured system for power plant applications features a brand new
customisation function which complies with the international standard IEC 61131-3.
APM802PRECISION AT YOUR FINGERTIPS.
OPERATING SCREEN
Generator set display
Display of installation and mechanical values
Display of generator set electrical values
User access:• shortcuts• maintenance• alarms
Generator set control (operating modes)
Control and position of circuit breakers
Operator and Specialist access:• curves• settings• history• configuration
Display of mains electrical values
Firewall
Remote access via smartphone, tablet or laptop
The ring is created by several Ethernet segments and groups together regulation and PLC communications.
With the ring redundancy option, all
functions remain fully operational
in all circumstances.
Control room
Remote control HMI
ETHERNET COMMUNICATION: INNOVATIVE AND PATENTED
The APM802 Ethernet communication guarantees a high level of equipment availability and facilitates the remote control of
HMI for an enhanced user experience. Additionally, various connections can be made via the Ethernet using fibre optics or
combined with copper wire. System communications are separated from external communications to allow full control of
risk management.
Illustration may vary from actual product.
SPEC YOUR JOB AT KOHLERPOWER.COM.SG 21
15-03517_IntlSpecA4.indd 21 3/2/16 11:19 am
VERSO
From 35A to 160A, the VERSO is the KOHLER changeover switch. Available in three phase
and single phase versions, it integrates the power detection and allows automatic/manual
start-up of the generator set in the event of a mains power cut.
In industrial applications, the transfer of the main source to the replacement source is crucial
for the running of your installations. Verso is the perfect solution for this requirement: from 35
to 160A, the Verso 100, and from 200A to 3150A, the Verso 200
Verso 100 VERSO S Single phase VERSO S Three phase VERSO D
Ratings (A) 63 100 125 160 35 63 80 100 125 160 35 63 80 100 125 160
Type Single phase Three phase Three phase
Nominal voltage/frequency 230V / 50-60Hz 127 / 230 V / 50-60Hz _ 230 / 400 V / 50-60Hz 127 / 230 V / 50-60Hz _ 230 / 400 V / 50-60Hz
Display and setting Potentiometer Potentiometer Via LCD display
Voltage drop tolerated 20% of the nominal voltage @230V 20% of the nominal voltage @400V 30% of the nominal voltage @400V
Protects against a change in the phase rotation direction X O •
Protection in "0" position X X Rapid automatic protection available for D versions
Lightning arrester X X O
Confirmation of mains return • • •
For France Only • • •
Protection index IP54 IP31 IP54
Dimensions (l x w x h) in, mm 305 x 410 x 150 385 x 385 x 193 400 x 600 x 200
• Standard O Option X Not available
Verso 200
Ratings (A) 200, 250, 315, 400, 630 800, 1000, 1250, 1600 2000, 2500, 3150
Type Three phase
Nominal voltage/frequency 127 / 230 V / 50-60HZ _ 230 / 400 V / 50-60HZ
Configuration Auto-configuration of voltage/frequency min/max and configurable thresholds
Display and setting By LCD - Supplied with manually-operated key - Can be padlocked in manual mode.
Voltage drop tolerated 30% of the nominal voltage @400V
Protects against a change in the phase rotation direction O
Lightning arrester O
EJP pack (for France only) X O O
Confirmation of mains return O
Protection index IP30 (54 on request) IP30 (54 on request) IP54
Inputs/outputs 3 configurable dry contact inputs/2 configurable relay outputs Modbus RTU via isolated RS485 available as an option
Dimensions (l x w x h) in, mm 800 x 600 x 400 1000 x 800 x 500 2000* x 1000 x 800 ≥ 800A
AUTOMATIC TRANSFER SWITCHESFORGET THE FORECAST. WE HAVE YOU COVERED.
22
15-03517_IntlSpecA4.indd 22 3/2/16 11:19 am
AIPR 1
Standard Option
With manual control on the front panel
3-pole open circuit breaker ✓
4-pole open circuit breaker ✓
Motorized control option*
With 3-pole circuit breaker, open type ✓
Other specifications
Voltage 208V-440V ✓
Power connection bus bars ✓
Protection index IP 23
Dimensions
height × width × depth, mm 1020 × 560 × 238
* The motorized control includes: a closing electromagnet, a shunt trip coil and an AC motor
THE CONTROL CONSOLES
Up to 630A, the power modules are integrated into the consoles. The extra-flexible cables between the console and the
alternator are fitted in a corrugated insulating sleeve.
AIPR
Above 630A, power modules called AIPR are separated from the control/command. These control boxes are fitted on the
generator set chassis and connected to the alternator.
POWER OUTPUT 2 poles 3 poles 4 poles
Modular circuit breaker from 10A to 125A ●(1) X(2) ●
Fixed unit circuit breaker 160A to 630A X ● ❍
(1) Only for single phase generator sets (2) As standard for some neutral connections ● Standard ❍ Option X Not available
POWER MODULES
SPEC YOUR JOB AT KOHLERPOWER.COM.SG 23
15-03517_IntlSpecA4.indd 23 3/2/16 11:19 am
Printed in SingaporeGSF-748 02/16
© 2016 by Kohler Co.
KOHLER® is a registered trademark of Kohler Co. Use of this material for reproduction on the Internet and World Wide Web
is strictly prohibited without written permission from Kohler Co.
SPEC YOUR JOB AT KOHLERPOWER.COM.SG
For more information on the complete range of Kohler products,please contact us at +65 6264 6422or visit KohlerPower.com.sg/Industrial
Southeast Asia Headquarters
Kohler Power Systems - Singapore7 Jurong Pier RoadSingapore 619159 Tel : +65 6264 6422 Fax: +65 6264 6455 Sales inquiries: [email protected]
Regional Sales Offices
S.E. Asia, Taiwan, Hong Kong& Bangladesh
Kohler Power Systems - Singapore 7 Jurong Pier RoadSingapore 619159 Tel: +65 6264 6422 Fax: +65 6264 6455 Email: [email protected]
Australasia
Kohler Power Systems - Australia PO Box 1351, Macquarie Centre Macquarie Park Sydney, NSW 2113Tel: +61 0 428 274 480Email: [email protected]
North Asia
Kohler Power Systems - JapanSBS Hills-II, No. 534-10-3, Yoga, Setagaya-Ku Tokyo 158-0097 Japan Tel: +81 3 6807 1730 Fax: +81 3 3708 4377 Email: [email protected]
Kohler Power Systems - KoreaRoom 1809 LG Twintel 2157-3 Samsung–Dong Gangnam-guSeoul 135-090 South Korea Tel: +82 2 563 9266 Fax: +82 2 563 9730 Email: [email protected]
15-03517_IntlSpecA4.indd 24 3/2/16 11:19 am