Differential threads provide distraction, indirect decompression
Implant design resists shear force
Immediate rigid fixation
Soft tissue-sparing access to L5-S1 disc space
![Page 3: International Meeting of Advance Spine Techniques](https://reader033.fdocuments.us/reader033/viewer/2022061607/558684cad8b42a9d7d8b45b5/html5/thumbnails/3.jpg)
Ability to compress, distract and reduceIntegrated extender tabs provide a pathway for rod delivery
Staged locking cap transforms head from polyaxial to monoaxial
![Page 4: International Meeting of Advance Spine Techniques](https://reader033.fdocuments.us/reader033/viewer/2022061607/558684cad8b42a9d7d8b45b5/html5/thumbnails/4.jpg)
Washer and screw combination for solid fixationSafe, reproducible posterior fixation Threaded working cannula ensures stable access to facet
![Page 5: International Meeting of Advance Spine Techniques](https://reader033.fdocuments.us/reader033/viewer/2022061607/558684cad8b42a9d7d8b45b5/html5/thumbnails/5.jpg)
Threaded Dilator Sheath-Atraumatic Threads assist to hold the channel against the facet
Facet Screw Driver-
Positive screw retention to the
driver
Cannulated for ability to deliver wire immediately after docking
Ability to decorticate the
facet capsule
![Page 6: International Meeting of Advance Spine Techniques](https://reader033.fdocuments.us/reader033/viewer/2022061607/558684cad8b42a9d7d8b45b5/html5/thumbnails/6.jpg)
Modular design allows optimal anchor placement
Conical tip guards against subsidence
Internal distraction against static anchors
Two-level construct resists shear forces
![Page 7: International Meeting of Advance Spine Techniques](https://reader033.fdocuments.us/reader033/viewer/2022061607/558684cad8b42a9d7d8b45b5/html5/thumbnails/7.jpg)
![Page 8: International Meeting of Advance Spine Techniques](https://reader033.fdocuments.us/reader033/viewer/2022061607/558684cad8b42a9d7d8b45b5/html5/thumbnails/8.jpg)
![Page 9: International Meeting of Advance Spine Techniques](https://reader033.fdocuments.us/reader033/viewer/2022061607/558684cad8b42a9d7d8b45b5/html5/thumbnails/9.jpg)
Berkeley Bi-Ostetic ™ Bone Filler
Chemical Composition : HA-TCP granules in a collagen matrix: FDA Clearance: BVF with Posteriolateral fusion indication
Granular Porosity : 85% (Human Cancellous Bone = 83.6%)
Interconnected Strut Pores
Dowels— 5cc (7 dowels)— 10cc (14 dowels)Strips— 1cc — 5cc — 10cc
![Page 10: International Meeting of Advance Spine Techniques](https://reader033.fdocuments.us/reader033/viewer/2022061607/558684cad8b42a9d7d8b45b5/html5/thumbnails/10.jpg)
Bilateral fixation comparable to pedicle screw fixation
360° Stabilization, fusion with soft tissue preservation