Internal use only Slide 1 ME7834 LTE Test System Training.

18
Internal use only Slide 1 ME7834 LTE Test System Training

description

Internal use only Slide 3 System Introduction What is ME7834 LTE Test System ? The ME7834 is a scalable system that is used primarily for supporting Carrier Acceptance Test Packages and Protocol Conformance Test Packages The ME7834 is a configurable system which supports the following Radio Access Technologies

Transcript of Internal use only Slide 1 ME7834 LTE Test System Training.

Page 1: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 1

ME7834 LTE Test System Training

Page 2: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 2

Agenda• System Introduction

• System Setup- Test Equipment- System IP Addresses- Boot up Sequence

• Support Information

• RTD Overview

• Tools & Debugging

• PCT Overview

Page 3: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 3

System IntroductionWhat is ME7834 LTE Test System ?The ME7834 is a scalable system that is used primarily for supporting Carrier Acceptance Test Packages and Protocol Conformance Test PackagesThe ME7834 is a configurable system which supports the following Radio Access Technologies

Page 4: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 4

ME7834L Device Test Platform• Flexible Protocol and Carrier Acceptance Test Solution for LTE FDD/TDD,WCDMA,CDMA2000• Conformance testing for wireless terminal

- World’s first test equipment supplier to meet the GCF - Protocol LTE device certification- Fast & reliable test execution- Unique parallel test capability- Automatically parameterise test cases according to the - UE capabilities

• Acceptance Testing for Carriers- Carrier validation & Acceptance Test- (AT&T, T-Mobile(USA), Verizon wireless)- Automation of test execution - Reports & Results (Pass/Fail)

• Support automated VoLTE tests for Carrier acceptance includes

- VoIP & VT Functional (IMS/SIP) tests- Audio Quality & Performance- Video Quality & Performance

Page 5: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 5

Page 6: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 6

MD 8430A• LTE Signaling Tester• 1 – 2 MD8430As in the system• Each MD8430A can have up to five firmware versions• Each MD8430A supports up to 6

cells ( 2- Communication , 4 – Neighbor)

Page 7: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 7

MD 8470A• CDMA Signaling tester• Upto 3 MD8470As in the system• Multiple MD8470As increases

maximum cells available• Used for Inter-RAT LTE 1X /

EVDO Test cases • Each MD 8470A supports 6 CDMA

sectors and 3 EVDO sectors on up to 2 RFs

Page 8: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 8

MD 8480C• HSPA /UMTS / GSM / GPRS /

EGPRS Signaling Tester• Upto 3 MD8480C in the system• Used for Inter-RAT LTE UTRAN-

GERAN Test cases &• Used also for UTRAN-GERAN only

Test cases• Each MD 8480C supports upto 4

WCDMA cells and 2 TDMA cells

Page 9: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 9

MF6900 Fading Simulator• Used for Throughput test cases

and SON-ANR test cases• Software Version 1.05.01 is used

Page 10: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 10

MN8141A Combiner• RF Combiner Unit• Combines RF feeds from

- MD8430A- MD8480C- MD8470A

• Used for all Inter-RAT test cases• Used for all PCT test cases

Page 11: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 11

Z1452A Linux Server• Dell R210 II Rack-Mount PC

running Red Hat Enterprise Linux 5.5

• IPV4 and IPV6 Supported• Software includes

- Automated Performance Measurement

- Anritsu IMS server- Router Advertisement Daemon- Iperf- FTP Server- HTTP Server

Page 12: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 12

System IP Addresses(1)• Data Server

- IPV4 Addresses- Ethernet 0 1.1.1.10 with

net mask 255.0.0.0

- Ethernet 1 192.168.1.2/24- Ethernet 1:1 192.168.2.2/24- Ethernet 1:2 192.168.2.3/24- Ethernet 1:3 192.168.3.1/24- Ethernet 1:4 192.168.4.2/24

- IPV6 Addresses

- Primary Address 1112::1113/64

- Secondary Addresses 2222::2222/64 , 2222::2223/64 3332::3332/64 , 4442::4442/64 aaa1::aaa1/64 , bbb1::bbb1/64 ccc1::ccc1/64 , aaa2::aaa2/64 1112::1114/64 ,1112::1112/64”

• MD8470A (Master)- Ethernet 0 (data)

192.168.254.2/24- Ethernet 1 (control) 1.1.1.2/8

• MD8470A (Slave#1)- Ethernet 0 (data)

192.168.254.3/24- Ethernet 1 (control) 1.1.1.3/8

• MD8470A (Slave#2)- Ethernet 0 (data)

192.168.254.4/24- Ethernet 1 (control) 1.1.1.4/8

• MF6900- 1.1.1.9/8

• RTD Control PC- 1.1.1.1/8

• PCT Control PC- 1.1.0.1/8

Page 13: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 13

System IP Addresses(2)• MD8430A

IP address is derived from the serial number and is of the form: 1.1ab.1cd.1ef, where a, b, c,d, e and f are the last 6 digits of the serial number labeled on the instrument.

• MD8480CIP address is derived from its serial number and is of the form: 1.1.1wx.1yz where w, x, y, z are the 4 digits of the serial number labeled on the instrument.

Page 14: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 14

Boot Up Sequence(1)Turn on all equipment except MD8470A(s), MD8430A and Data Server PC. Then follow the boot sequence in section Boot up Sequence for a Single MD8470A or section Boot up Sequence for Multiple MD8470As to avoid the conditions mentioned below.• Boot up Sequence for a Single MD8470A

- Boot the MD8470A.- Ensure the IP addresses on the MD8470A are as follows:- Ethernet 0 (data) 192.168.254.2/24- Ethernet 1 (control) 1.1.1.2/8- Start the MX847030A and MX847031A Remote Interface applications

on MD8470A.- Boot the MD8430A.- Boot the Server PC.

Note: Do not change the MD8470A IP addresses after the system has been initialized.

Page 15: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 15

Boot Up Sequence (2)• Boot up Sequence for Multiple MD8470As

- Boot both Master and Slave MD8470A.- Ensure the IP addresses on both MD8470As are as follows:

MD8470A (Master)Ethernet 0 (data): 192.168.254.2/24Ethernet 1 (control): 1.1.1.2/8

MD8470A (First Slave)Ethernet 0 (data): 192.168.254.3/24Ethernet 1 (control): 1.1.1.3/8

- On the MD8470A (Slave), set the Reference Signal to External on the Session Daemon.

- On the MD8470A (Slave), start the MX847030A (Slave) application.- Wait for the Command prompt message: Wait for Response #1.- On MD8470A (Master), start the MX847030A (Master) application.- Wait for the message: Synchronizing.

Page 16: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 16

Boot Up Sequence (3)- Wait for the message: Success.- On both MD8470A (Master) and MD8470A (Slave), start the

MX847031A Remote Interface applications.- Boot the MD8430A.- Boot the Server PC.

Note: Do not change the MD8470A IP addresses after the system has been initialized.

• MD8430A Address ResolutionThe MD8430A replies to all ARP requests received on the MD8480C 10/100Base-T port. This behavior can cause problems with MD8470A network communications, which may result in loss of CDMA2000® logging support or data path stability. This condition can be avoided by booting the system in a specific order.

Page 17: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 17

Control PC’s• System can contain up to three Dell PC’s• RTD control• PCT control• AAP

Page 18: Internal use only Slide 1 ME7834 LTE Test System Training.

Internal use only Slide 18

System Support• For any queries regarding the ME7834 system please send an

email to

[email protected]