Interior Decoration & Furnishing

120
ONGC TRIPURA POWER COMPANY LIMITED TECHNICAL SPECIFICATIONS FOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS 2 X 363.3 MW GAS BASED COMBINED CYCLE POWER PLANT, PALATANA, UDAIPUR, TRIPURA (This document is meant for the exclusive purpose of bidding against this specification and shall not be transferred, reproduced or otherwise used for purposes other than that for which it is specifically issued).

description

Technical Specification for Interior Decoration & Furnishing

Transcript of Interior Decoration & Furnishing

Page 1: Interior Decoration & Furnishing

ONGC TRIPURA POWER COMPANY LIMITED

TECHNICAL SPECIFICATIONS

FOR

INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS

2 X 363.3 MW

GAS BASED COMBINED CYCLE POWER PLANT,

PALATANA, UDAIPUR, TRIPURA

(This document is meant for the exclusive purpose of bidding against this specification and shall not betransferred, reproduced or otherwise used for purposes other than that for which it is specifically issued).

Page 2: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATION FOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGSTABLE OF CONTENT

Clause No. Description Page No.A. TECHNICAL SPECIFICATIONS FOR INTERIOR WORKS – CIVIL1.0 SPECIFICATIONS FOR INTERIOR WORKS 062.0 HARDWARE 103.0 METAL WORK 114.0 MIRROR 125.0 P O P PUNNING 136.0 GLASS AND GLAZING 147.0 PAINTING, WHITE WASHING, COLOUR WASHING & DISTEMPERING 168.0 BLINDS 179.0 STANDARD WORKMANSHIP 1710.0 MATERIAL ORDER STATUS / RECEIPTS AT SITE 1711.0 MODE OF MEASUREMENT OF WORKS 1812.0 DESCRIPTION OF WORK: HOW MEASURED MULTIPLYING FACTOR 18B. TECHNICAL SPECIFICATION FOR INTERIOR WORKS – ELECTRICAL1.0 GENERAL TERMS 212.0 REGULATION & STANDARDS 213.0 SCOPE OF WORK 224.0 POINT WIRING 235.0 MEASUREMENTS OF POINT WIRING 246.0 CIRCUIT WIRING, SUB-MAIN WIRING AND ITS MEASUREMENT 257.0 6 & 16 AMP SWITCH SOCKET OUTLET – MODULAR RANGE 258.0 LIGHTING FIXTURE AND FANS 269.0 LAMP HOLDERS, CEILING ROSES & BALLASTS 2610.0 TESTING & INSTALLATION 2711.0 WIRING SPECIFICATION 2812.0 SWITCH-OUTLET BOXES AND JUNCTION BOXES 3213.0 CONDUCTORS 3314.0 EARTHING 3515.0 TESTING 3816.0 SAFETY REQUIREMENTS 3917.0 FIRE DETECTION AND ALARM SYSTEM 40C. TECHNICAL SPECIFICATION FOR FURNITURE1.0 SPECIFICATIONS FOR FURNITURE / INTERIOR WORKS 452.0 WOODEN STORAGES 473.0 STORAGES IN CONFERENCE ROOM 474.0 METAL STORAGES 475.0 CHAIR WITHOUT HEADREST 486.0 CHAIR WITH HEADREST 487.0 CHAIR WITH FIXED ARM 498.0 CHAIR WITH ADJUSTABLE ARM 509.0 READING CHAIR 5110.0 CHAIR FOR CAFETARIA 5111.0 3 SEATER SOFA IN OFFICE ROOM 5112.0 CHAIR WITH CHROME BASE 5113.0 CHAIR MESH TYPE WITH FIXED BASE 5214.0 CHIARS 53

Page 3: Interior Decoration & Furnishing

15.0 STOOL FOR PATIENT 5316.0 SOFA 5317.0 MANAGER TABLE LAMINATED 5418.0 MANAGER TABLE PRE-LAMINATED BOARD WITH SIDE STORAGE METAL

MODESTY55

19.0 MAIN TABLE 5620.0 CHAIRMAN TABLE IN VENEER FINISH 5721.0 CENTER TABLE AND CORNER TABLE IN MANAGER’S CABIN 5822.0 CENTER TABLE AND CORNER TABLE 5823.0 DISCUSSION TABLE 5824.0 LAB WORKING PLATFORM 5925.0 LOCKERS LAB 5926.0 BENCHES IN LOCKER ROOM 6027.0 DISPLAY BACK 6028.0 TABLE FOR PLANT SCALE 6029.0 READER’S TABLE 6130.0 WOODEN LIBRARY RACKS 6131.0 TABLES (MAIN TABLE) WITH PEDESTAL, KETBOAD TREY & CPU TROLLEY 6232.0 SINGLE BED IN HOSTEL 6333.0 DOUBLE BED IN HOSTEL 6334.0 BED FOR PATIENT 6335.0 SEMINAR HALLL AREA 6436.0 RECEPTION TABLE 6437.0 MODEL AND CHART TABLE 6438.0 CAFETARIA TABLE 6539.0 METAL RACK 6540.0 LECTURE ROOM TABLE 66D. GENERAL SPECIFICATION FOR CEILING & PARTITION1.0 GENERAL REQUIREMENTS 682.0 STANDARD WORKMANSHIP 693.0 CEILING WORK 694.0 POST CAP METAL CEILING SYSTEM 705.0 CANOPY METAL CEILING SYSTEM 726.0 CORRIDOR METAL CEILING SYSTEM 747.0 CLIP IN METAL CEILING SYSTEM 768.0 METAL BAFFLE CEILING SYSTEM 789.0 SINGLE GLAZING FULL HEIGHT PARTITION SYSTEM 7910.0 SINGLE GLAZING FULL HEIGHT PARTITION SYSTEM (WITH METAL PANEL) 8111.0 TIMBER WALL CLADDING 8212.0 DOUBLE GLAZING FULL HEIGHT PARTITION SYSTEM 8313.0 DOUBLE LAYER WOODEN PANEL PARTITION SYSTEM 84E. TECHNICAL SPECIFICATION FOR SYSTEM INTEGRATION WORK1.0 DISPLAY SYSTEM 882.0 SOURCE EQUIPMENTS 883.0 AUDIO RE-INFORCEMENT SYSTEM 884.0 CONTROL SYSTEM 895.0 CABLES AND CONNECTORS 896.0 OTHER MISCELLANEOUS ITEMS 897.0 AUDIO VIDEO SYSTEM FOR 100 SEATER AUDITORIUM 908.0 DISPLAY SYSTEM FOR LECTURE HALL SOLUTION 949.0 AUDIO RE-INFORCEMENT SYSTEM FOR EXECUTIVE TRAINING ROOM 9410.0 BACKGROUND MUSIC SYSTEM FOR CANTEEN 95

Annexture-I LIST OF INDIAN STANDARDS 96Annexure-II LIST OF APPROVED MAKES OF MATERIAL – INTERIOR & CIVIL WORKS 99

Page 4: Interior Decoration & Furnishing

LIST OF APPROVED MAKES OF MATERIAL – ELECTRICAL WORKS 101LIST OF APPROVED MAKES OF MATERIAL – CEILING 102LIST OF APPROVED MAKES OF MATERIAL – FURNITURES 102LIST OF APPROVED MAKES OF MATERIAL – SYSTEM INTEGRATION WORKS 103

Annexure-III TENDER DRAWINGS 117

Page 5: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 5

TECHNICAL SPECIFICATION FOR INTERIOR WORK - CIVIL

Page 6: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 6

1. SPECIFICATIONS FOR INTERIOR WORKS

1.1. GENERAL REQUIREMENTS.

1.1.1. The section of the specification shall be read in conjunction with the Drawings,other Contract Documents and other sections of these specifications which shallbe deemed to be complementary to one another. The Contractor carrying ourthis work shall be responsible for providing all plant, tools, materials and allthings necessary for the proper execution, completion and maintenance of theseworks.

1.2. DIMENSIONS

1.2.1. Figured dimensions shall be taken in preference to scaled dimensions in allcases. Before commencing any work the Contractor shall verify all requirementson the Site.

1.3. SAMPLES

1.3.1. A Sample of every item of furniture / paneling / cladding / flooring /false ceilingall other components, including their parts shall be submitted for approval beforean order is placed or manufacture commences. Approved samples shall be usedas standards of finish and workmanship.

1.4. JOINTS AND ADHESIVES

1.4.1. All joints shall be standard Mortise and tennon / dowel / dovetail / cross-halved /mitred / tongue & groove / rebated. Nailed butt joints will not be permittedexcept where shown in the drawings. Where mortise and tennon joints areshown in the drawings, tennon shall fit the mortises exactly. Adhesives shall beresin based for all carpentry work and as per approval of the Project Manager /Architect. Lap joints with glue shall be permitted in wood skirting.

1.5. FASTENINGS

1.5.1. Screws, nails etc, shall be of standard iron / wire unless otherwise shown ondrawings. Screws and nails for outdoor furniture shall be of brass or other non-corrosive metal. Exposed fastenings shall match the finish of hardware. Wherescrews show on a finished surface, they shall, unless otherwise detailed, be sunkand the hole plugged with wood plug of the same wood and grain of the finishedsurface. Nails on finished surfaces shall be neatly punched and the hole filledwith wood filter to match. Filling putty over screw or nail holes shall not bepermitted.

1.6. HARDWARE

1.6.1. Hinges, locks, latches, door tracks, nail hides etc shall be as specified or anapproved substitute equal to or better than the specified.

1.7. METAL

1.7.1. Where metal legs, frames and the like are used, these shall be welded, brazed,bolted or as required, and on finished surfaces, welding, brazing, and rivetingshall be ground so that no evidence of this is apparent on the final finish of the

Page 7: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 7

metal. All legs of case or cabinet furniture whether of wood or metal, shall beequipped with nylon glides or castors unless otherwise shown on the drawings.

1.8. FINISH

1.8.1. Finishes shall be fully in accordance with the drawings and schedules. Wheretimber is in natural finish, pieces shall be matched for colour and grain beforeassembly. Where timber is stained the stain shall be matched throughout.Backs of wall-hung case of cabinet furniture shall be treated with an approvedbrand of wood preservative.

1.9. CUSHION VENTS

1.9.1. Cushion vents shall be made in the back or underside of all seat cushions insufficient number to allow air to escape easily and prevent torn seams.

1.10. MOISTURE CONTENT OF CARPENTRY

1.10.1. The moisture content of timber during manufacture, delivery to the Site,Storage, Site Working, Assembly and Installation shall have moisture content of12% nominal.

1.11. SUPERIOR QUALITY TEAK/PADAUK

1.11.1. It shall be of good quality and well-seasoned. It shall have uniform colour,reasonably straight grains and shall be free from large, loose, dead knots,cracks, warps, twists, bends, borer holes, shakes, sapwood or defects or anykind. No individual hard and sound knot shall be more than 1 cm. In diameterand aggregate area of all knots shall not exceed ½% of the area of the piece. Itshall be close grained and there shall not be less than six growth rings per 2.5cm. width.

1.12. WOOD WORK

1.12.1. Timber used shall confirm to specifications described under materials, shall be inaccordance with the Architects drawing in every details and all joiner’s work shallaccurately set out, framed and finished in a proper workmanlike manner. Framesof partitions and opening, etc., shall be of accurately planned smooth andrebates, roundings and mouldings shall be made as shown on the drawings.Patching or plugging of any kind shall not be allowed. Joints shall be simple,neat and strong.

1.12.2. Framed joints shall be coated with suitable adhesive like glue or synthetic resinbefore the frames put together. All mortice and tenon joints shall fit in fully andaccurately without wedging or filling. The joints shall be pinned with hardwoodor bamboo pins of 10mm to 12mm dia, or rust resisting star shaped metal pintsof 8mm dia, after the frames are put together and pressed in position by meansof a press. The frames shall be protected during the progress of work byproviding suitable boxing. All portions of timber abutting against or embedded inmasonry or concrete shall be treated against termites by giving a coat of anyapproved wood preservative. All T.W. work should be painted with a cost ofapproved wood primer.

1.12.3. No extra measurements will be given for the shape, joints of the partitionscounter, tables work etc.

Page 8: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 8

1.12.4. All work shall be measured net as fixed. No extra measurement will be given forshape, joints, played meeting styles of doors and windows and shall bemeasured in unit of square feet.

1.12.5. Areas over one face inclusive of exposed frame thickness (excluding width ofcover mould) shall be measure in case of T.W. Doors, windows, and ventilators,Louvers, Portions in masonry or flooring shall not be measured.

1.12.6. Frames and shutters shall not be painted or erected before being approved bythe Client/Architects.

1.13. Upholstery

1.13.1. Where the upholstery fabric is patterned no upholstery fabrication is tocommence until the Contractor has received clear instructions concerning thedirection of the pattern and the method of its joining. Upholstery will be of firstclass workmanship with webbing, no-sag springs, coiled springs, padding andfilling as specified. Covering fabrics will be sewn, tufted and corded as shown onthe drawings or schedules.

1.14. PROTECTION, DELIVERY AND STORAGE

1.14.1. While remaining in proper wrappers the timber shall be protected from extremesof temperatures and direct sunlight.

1.14.2. Internal joinery and joinery timber shall be kept in its original wrappers beforeworking, fixing and installing on Site.

1.14.3. All joinery to be painted shall be approximately sealed with the specified primerto all faces before leaving its place of manufacture. All joinery to be varnished /spirit polished shall be sealed with at least one coat of specified varnish polish atall faces before leaving its place of manufacture. All joinery and joinery timbershall be wrapped in proper cover before and during transport and delivery toSite.

1.14.4. Proper warping to external joinery and timber shall be removed on delivery toSite or as previously specified.

1.14.5. All timber used shall be kiln seasoned. Fire Retardant paint shall be used on allhidden timber wherever indicated / specified anywhere in the drawings,specifications and the various parts of this Document. All woodwork exposed orunexposed done by the Contractor shall be coated in a colourless fire retardingpaint of brand approved by CBRI and Fire authorities. The painting work shallbe done by soft brushes, and by pencil brushes in corners etc. The rate wouldinclude providing all material brushes etc. No extra payment would be made forthe same.

1.15. BUILDERS HARDWARE

1.15.1. All hardware fittings and fixtures shall be made with structural properties tosustain safety and withstand strains and stresses to which they are normallysubjected to such as opening and closing, wind pressure etc. The fittings shallgenerally conform to relevant specifications.

Page 9: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 9

1.15.2. They shall be made true, clear straight with sharply defined profiles and unlessotherwise shown or specified with true smooth surfaces and edges, free fromdefects. Screw holes shall be counter sunk to suit the head of wood screws.

1.16. MELAMINE FINISH - GLOSSY/ NATURAL : TECHNICAL DATA

1.16.1. Thinner recommended : Brushing – Thinner 1061.16.2. Spraying – Thinner 1241.16.3. Mixing ratio : Base to hardener in 10:1 by volume1.16.4. Drying Time : 8 Hours1.16.5. Surface dry-less than 30 minutes1.16.6. Hard Dry 16-20 hours1.16.7. Re-coating period-overnight1.16.8. Finish : 25 microns film thickness smooth and glossy

1.16.9. Flash point: Above 14 degree C (57 degree F) Sand the surface along the grainswith Emery paper No: 180 or with a suitable grade sand paper. Brush thesurface free of loose dust. Fill the wood using wood filler. Remove excess fillerimmediately after applications. Allow 2-3 hours of drying before sanding withEmery paper no: 240-280. If desired, apply Apcolite wood stains by raggingafter filling step or mix it in Natural Wood Finish upto 20% by volume and applyby spraying after Sealer Coat. In application by ragging allow a drying time of 5-10 minutes in between coats and 30-60 minutes before over coating with finishcoats. Apply a coat of Natural Wood finish Clear Sealer. After overnight drying,smooth sand with Emery Paper No: 320 and wipe the surface free of loose dust.Apply Apcolite Natural Wood Finish Clear Glossy as follows. Ensure that thesurface to be coated is free from loose matter. Natural Wood Finish clear Glossyis a two component system consisting of base and hardener. These should bemixed in a glass, plastic or enameled container. Allow the mixture to stand for30 minutes and then apply by brushing or spraying using the recommendedthinner for consistency adjustment. The mixture of base and hardener should beused within 8 hours. To enhance gloss and decorative value Natural Wood FinishClear Glossy can be buffed using suitable buffing mops but only after 48 hoursof application.

1.17. KAILWOOD / MARANDI

1.17.1. Wherever kailwood is specified it shall mean First Class Kailwood / Marandi/equivalent as per approval of the Project Manager / Architect / ACE.

1.18. PLASTIC LAMINATE VENEER

1.18.1. Plastic decorative laminated veneer sheeting shall be ISI marked or the brand,catalogue number and colour indicated and approved. The laminated veneershall be 1.5 mm thick on flat surfaces and 1 mm thick on curved surfaces unlessotherwise approved.

1.18.2. Plastic laminate veneer shall be fire retardant to Class 1 of BS: 476 or ISI Codewhere specified.

1.18.3. Lengthwise on horizontal surfaces

1.18.4. Vertical on vertical surfaces

Page 10: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 10

1.18.5. Horizontal on edges of top surfaces and shelves.

1.18.6. No surface sanding of laminated plastics will be allowed.

1.18.7. Unless otherwise specified, all laminated plastics shall have a standard matt orsuede finish unless where mentioned.

1.18.8. Samples of laminated plastics showing the surface texture and pattern shall besubmitted for approval before fixing.

1.19. Particle Board / Graded Particle Board

1.19.1. The Particle board shall comply with ISI specifications and shall be one madefrom wood particles and flat pressed with synthetic resin and/or organic binder.Thickness shall vary as shown on drawings.

1.19.2. Particle board shall not be used externally or internally in any essentially dampsurroundings.

1.19.3. Manufacturer and reference for Particle Board shall be subject to approval.

1.20. SAMPLES OF VENEER

1.20.1. The Contractor shall submit a sample of each type of veneer for approval beforegeneral fabrication is started.

1.20.2. Interior Designing and Fabrication of Foam Panels : Panels shall be InteriorDesigned of fabric on foam on new timber framing with insulation quilt in-fill.

1.20.3. Framing shall be Interior Designed of approved sections as per drawing andadequately braced to ensure rigidity. All outer exposed edges and corners shallbe pencil rounded. Joints shall be subject to approval. Screws and nails shall becounter sunk and punched below the surface.

1.20.4. The fabric shall be back faced with synthetic foam. The foam shall cover allouter edges and corners of the framing and securely fixed in place to the back ofthe framing with approved marking cloth.

1.20.5. The fabric shall be evenly stretched over the foam covered framing to obtain atight flat and evenly finished surface. The fabric sha8ll be returned over theframing edges and lapped 50mm over the back face of the framing and securelyfixed.

1.21. PROTECTION OF PANELS

1.21.1. Panels shall leave the factory in perfect condition and in protective wrappers andbe properly protected from damage.

1.21.2. Panels shall be stacked in dry well-ventilated conditions off the ground. Theoriginal protective wrappers shall be removed immediately prior to installation ofthe panels.

1.21.3. The Contractor shall be responsible for protecting all items of work in thissection in these areas of work forming part of his own expense any damagedwork caused through lack of adequate protection or care in installation orhandling.

1.21.4. The Contractor shall make his own investigation to guard against local sources ofattack and damage and take all necessary precautions of protection.

2. HARDWARE

Page 11: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 11

2.1. Hinges, locks, latches, door tracks etc shall be in SS brushed steel finish or asspecified and as far as possible of specified manufacture. In case of anyvariation in quality, the substitute shall be equal to or better than the originallyspecified and the sample should be submitted to the Architect for prior approval.

3. METAL WORK

3.1. The Contractor shall furnish all materials, labour, operations, equipment, tools,plant and incidentals necessary and required for the completion of all metal workas called for in the Drawings. The Drawings and Specification cover the majorrequirements only. The supplying of additional fastenings, accessories, featuresand other items not mentioned specifically herein but which are necessary tomake a complete installation shall be part of this Contract.

3.2. All metal work shall be free from defects importing strength, durability andappearance and shall be of the best commercial quality for purposes specified,made with structural properties to withstand safety strains, stresses to whichthey shall be normally subjected.

3.3. SAMPLES OF METAL WORK

3.3.1. Samples of all typical metal work shall be fabricated assembled and erected orsub mitted to the Architect as directed by him for approval.

3.3.2. Where metal legs/frames/sheets etc are used, these shall be welded, brazed,bolted or riveted as required. On finished surfaces welding, brazing and rivetingshall be neatly smoothed so that no evidence of this is apparent on the finalfinish of the metal which will be specified in the drawing.

3.3.3. On all legs, wood or metal, nylon glides or castors as indicated are to beinstalled.

3.3.4. BUTT HINGES : These shall be of the heavy duty S.S. (14 gauge) of powdercoated of size required with powder coated screws. M.S. hinges shall bemanufactured by casting, unless it is specifically mentioned that the same shallbe extruded type in which case these shall be manufacturer from extrudedsections. Hinges shall be finished as specified in the respective items. The size ofbutt hinges shall be taken as length of the hinge.

3.3.5. FLOOR SPRING AND PIVOT: Hydraulically regulated floor spring and pivot shallbe conforming to IS for heavy duty performance. Suitable adjustments shall bemade such that the closing time can be raised five seconds to twenty-fiveseconds. The oil filling shall work well in all seasons and shall not show anysigns of leakage of oil under working conditions. The supplier shall supply alongwith the closer a wrench and spanner for carrying out adjustments. Paymentsshall be made per number and includes supply of all accessories, fixing the doorpivot/ floor spring, anodizing / painting etc complete as per directions of ProjectManager.

3.4. PAINTING-OIL/ENAMEL/PLASTIC EMULSION ETC.

3.4.1. Ready mixed oil paint, plastic, emulsion paint, ready mixed synthetic enamelpaint, Aluminium paint, etc. shall be brought in original containers and in sealedtins. If or any reason thinner is necessary the brand and quantity of thinnerrecommended by the manufacturers or as instructed by the Architects shall beused.

Page 12: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 12

3.4.2. The surface shall be prepared as specified above and cost of approved primershall be applied. After 24 hours drying, approved if specified quality paint shallbe applied evenly and smoothly. If required a filler putty coating may be given togive smooth finish. Each coat shall allowed to dry out thoroughly and then lightlyrubbed down with sand paper and cleaned of dust before, the next coat isapplied. Number of coats shall be as specified in the item and if however thefinish of the surface is not uniform additional coats as required shall be appliedto get good and uniform finish at no extra cost. After completion no hair marksfrom the brush or clogging of paint puddles in the corners of panel angles ofmouldings shall be left on the work. The glass panes floor etc. shall be cleanedof strains.

3.4.3. When the final coat is applied, if directed, the surface shall be rolled with a rolledor if directed it shall be stippled with a stippling brush.

4. MIRROR

4.1. GENERAL REQUIREMENTS OF MIRROR

4.1.1. This section of the Specification shall be read in conjunction with the Drawingsand Schedules and other section of the Specification which shall be deemed tobe complimentary to one another. The Contractor carrying out this work shallbe responsible for providing all plants, tools, materials and all things necessaryfor the proper execution, completion and maintenance of these works.

4.2. SAMPLES OF MIRROR

4.2.1. The Contractor shall submit samples of all glass and mirror types for approval./these shall be obtained from an approved source.

4.3. DELIVERY AND STORAGE OF MIRRORS

4.3.1. Delivered materials, shall match the approved samples, packaged materials shallbe delivered in the original, unopened, labeled containers of the manufacturerclearly marked with their name and brand.

4.3.2. Mirror shall be stored while awaiting installation in a dry, well-ventilated locationat a constant temperature maintained above dew point.

4.3.3. Handling of mirrors shall be kept to a minimum. Mirrors shall be protectedagainst soiling, condensation, etching and the like.

4.4. MARKING MIRROR

4.4.1. Manufacturer’s or job marking on mirror and adhesive for manufacturer’s labelsshall not be alkaline but shall be either neutral or slightly acidic so that it isremoved after its installation.

4.5. CUTTING MIRROR

4.5.1. Cutting of mirrors shall be in accordance with site measurements or dimensions.Mirror shall be fabricated from clear plate or float glass of the quality and finishshown in the Drawings and Schedules unless otherwise required.

4.6. THICKNESS OF MIRRORS

Page 13: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 13

4.6.1. All fixed panel mirrors shall be as per specification given by Architect unlessotherwise stated having plus/minus 0.30mm tolerance.

4.7. EDGES OF MIRRORS

4.7.1. All edges of mirrors shall be polished, beveled, corner mitered to ISISpecifications or as indicated in the drawing.

4.8. DRILLING OF MIRRORS

4.8.1. All drilling of holes shall be carried out at the stage of fabrication. No chipping,starring and other visible imperfections around holes will be accepted.

4.9. FIXING OF MIRORS

4.9.1. Panels shall be securely fixed with screw on “Z” clips at minimum 600mmcenters horizontally and 1200 mm centers vertically.

4.9.2. Mirrors shall be fixed to backings by adhesive or special fixings as shown on thedrawings or as otherwise specified using CP cap screws.

4.9.3. Screws shall be of brass with collars and screw-on domes unless otherwisespecified.

4.10. FINISHING OF FIXINGS

4.10.1. All visible metal fixings shall be of approved finish to match mirror finish andcolour.

4.11. ADHESIVES FOR MIRRORS

4.11.1. Adhesives shall be as recommended by the silvering manufacturer and used inaccordance with the manufacturer’s recommendations.

4.12. JOINTS OF MIRRORS

4.12.1. Paper thin joints shall separate all adjoining sections of mirrors.

4.13. PROTECTION OF MIRRORS

4.13.1. Mirror shall be protected from paint, plaster, welding splatter, Interior Designingscum and the like. Should any such soiling occur, the mirror shall be promptlyand completely washed off as specified below.

4.13.2. Mirror generally shall be protected with temporary wooden barricades or otherwarning devices as a deterrent against passing objects through glazed openings.

4.14. CLEANING OF MIRRORS

4.14.1. When directed by the Architect, the Contractor shall remove all markings andlabels from mirror and wash the mirror with mild neutral or slightly acidicsolution as recommended by the mirror manufacturer. Alkaline or abrasivesolutions should not be used.

5. P O P PUNNING

5.1. GENERAL

Page 14: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 14

5.1.1. Plaster of Paris punning (Plaster) is generally applied on already cementplastered surface to give it a smooth and even surface.

5.2. PREPARATION OF SURFACE

5.2.1. Projecting burrs of mortar existing on cement plaster shall be removed. Thesurface shall be scrubbed clean with wire brushes. In addition the plasteredsurface shall be pock marked with pointed tool, at spacing of nor more than 4cms c/c and depth of pock to be approx. 3 mm. This is to ensure a proper keyfor the plaster. The surface shall be cleaned of all grease marks etc.

5.3. PLASTER OF PARIS

5.3.1. The Plaster of Paris shall be of semi-hydrate variety Calcium Sulphate. Itsfineness shall be such that when sieved through a sieve of ISI sieve designation3.35 mm for 5 minutes after drying the residue left on it shall be not more than1% by weight. It shall not be too quick setting. Initial setting time should notbe less than 13 minutes.

5.4. APPLICATION OF PLASTER OF PARIS

5.4.1. The material will be mixed with water to a workable consistency. Plaster of Parisshall be applied directly on the wall plaster in suitable size panels and finished toa smooth surface by steel trowels. The plaster shall be applied in such a mannerthat it fully fills the gaps, and the thickness over the plastered surface is asspecified in the description of the item.

5.4.2. The finished surface shall be smooth and true to plane, slopes or curves asrequired.

6. GLASS AND GLAZING

6.1. EXTENT AND INTENT

6.1.1. The Contractor shall furnish all materials, labour, tools, appliances, equipmentand INCIDENTALS REQUIRED TO COMPLETE THE INSTALLATION OF ALL GLASSAND RELATED ITEMS.

6.1.2. All glass shall be of the type, quality and substance specified. All glass shall befirst class in every respect and conform to ISI: 1761-1960. The glass shall be100% free from blisters, stains, scratches and bubbles so as not to distortvisibility.

6.2. GLASS SIZES

6.2.1. The Contractor shall cut glass sizes by field measurements or dimensionallyapproved shop drawings. The responsibility for correct glass sizes shall rest withthe Contractor. No cracked, chipped or disfigured glass shall be accepted.

6.3. GLASS BREAKAGE

6.3.1. The Contractor shall replace all broken, damaged and disfigured glass caused inexecuting the work or by faulty installation before hand-over, at his own cost.

6.4. MELAMINE FINISH

Page 15: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 15

6.4.1. Timber works shall be finished by the application of two coats of an acidcatalyzed clear lacquer (melamine) wherever it is indicated in the drawing. Thefinish shall be a satin, semi-gloss finish and shall be carried out as follows:

6.4.2. The base shall be sand papered to the desired finish and coated with a colourtinge to give it shade. The shade shall be sealed with a coat of spirit finish.

6.4.3. After the base, first coat of lacquer shall be applied evenly by a soft cloth or byspray to give an even coat to the veneer surface.

6.4.4. After the first coat has fully dried, the lacquered surface shall be rubbed down inthe direction of the veneer grain with very fine glass paper and left completelysmooth and clean before the second coat is applied.

6.4.5. When the second coat of lacquer is fully dry, the surface shall be rubbed down inthe direction of veneer grain with very fine wire wool dipped in a petroleumbased wax to give lubrication.

6.4.6. Twenty-four hours after completion of this process the lacquered veneer surfaceshall be finished by burnishing with a soft cloth to an approved finish.

6.5. MATERIALS FOR GLASS

6.5.1. Glass for all glazing work shall be plain flat glass as called for in the Drawingsand schedules. Flat glass for glazing shall be 6 mm / 8 mm thick special selectedquality glass as called for, manufactured by Saint Gobain / Modifloat or otherequivalent as approved by the Architect.

6.6. TOUGHENED GLASS

6.6.1. The toughening of glass, where called for shall be carried out by M/s. HindustanSafety Glass Works or M/s. Atul Glass Works or any approved vendor to the beststandards available standards.

6.7. GLAZING COMPOUND

6.7.1. Glazing putty for setting glass shall be approved quality (Shalimar or approvedequivalent) suitable for use on metal windows and conforming to ISI 420-1953.Gasket and Glazing shall be of Neoprene or EPDM of approved quality and make.

6.8. PREPARATION OF FRAMES AND GLASS

Before installation the Contractor shall ensure that

All glazing rebates are square, plumb and true in plane, clear, dry and dustfree.

All frame adjustments are made prior to glazing.

All glass edges are clean, cut to exact sizes and grout properly allowing forexpansion tolerance as recommended by the glass manufacturer.

All sashes shall be glazed in the closed position and shall not be opened untilthe compound is set.

All materials are used in strict accordance with the manufacturer’sinstructions.

Glass shall not be forced into place.

Page 16: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 16

All rebates / beadings etc to be pre-polished.

6.9. GLAZING

6.9.1. All glass is to be of approved manufacturer of approved quality and shall be freefrom bubbles, smokes, waves, air holes and other defects. The kind of glass tobe used shall be as mentioned in the item or specification or in the specialprovisions or as shown in detailed drawings. Thickness of glass panel shall beuniform. All glass to be approved manufacture complying with IS: 3548 – 196 oras per approved quality and sample.

6.9.2. The compound for glazing to metal is to be special non-hardening compoundmanufacture for the purpose and of 9 brand and quality approved the EIC.

6.9.3. While cutting glass, proper allowance by made for expansion. Each square ofglazing to be in one whole sheet. On completion of work, all glass shall becleaned inside and outside and all cracked scratched and broken panes shall bereplaced and left in a good condition.

6.9.4. All exposed edges of glass shall be lead polished.

6.10. INSTALLATION & COMPLETION OF GLASS

6.10.1. The glass shall be set on Neoprene or EDPM blocks on all sides. Glass shall bebedded back and face and so installed as to achieve a completely water tightand rattle free installation. The odd glass where called for shall be set withsmooth surface outside.

6.10.2. Upon the completion of the work all glass shall be thoroughly cleaned, paint orother marks removed. Any cracked, scratched, chipped or other defective glassshall be removed and replaced without cost of Owner. Any loose glass shall beset to the satisfaction of the Architect.

7. PAINTING, WHITE WASHING, COLOUR WASHING & DISTEMPERING

7.1. PAINT AND POLISHING

7.1.1. All materials required for the works shall be of a specified and approvedmanufacturer, delivered to the site in the manufacturer’s containers with theseals etc unbroken and clearly marked with the manufacturer’s name ortrademark with a description of contents and colour. All material to be stored onthe Site of works.

7.1.2. Spray painting with approved machines will be permitted only if prior writtenapproval has been obtained from the Architect. No spraying will be permitted inthe case of priming coats or where soiling of adjacent surface is likely to occur.The nozzle and pressure to be so operated as to give an even coatingthroughout to the satisfaction of Architect. Thinning of paint made for brushingwill not be allowed.

7.1.3. Wood preservation shall be Soligam or any other equal / approved impregnatingwood preservative and all concealed woodwork shall be so treated.

7.1.4. All brushes, tools, pots, kettles etc used in carrying out the work shall be cleanand free from foreign matter and are to be thoroughly cleaned out before beingused with a different type or classes of material.

Page 17: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 17

7.1.5. All iron or steel surfaces shall be thoroughly scrapped and rubbed down withwire brushes and shall be entirely free from rust, mill scale etc before applyingthe priming coat.

7.1.6. Surface of previous painted metal which are to be repainted shall be cleaned andflattened down as described in surfaces of previously painted woodwork. Minorareas of defective paint and any rust / loose scales shall be removed completelyby chipping, scraping and wire brushing back to the bare metal and touched upwith primer as described.

7.1.7. Surfaces of new wood-work which are to be painted are to be rubbed down forapproval of the Architect prior to application of paint.

7.1.8. Surfaces of previously painted woodwork which are to be repainted shall becleaned down with soap and water, detergent solution or approved solvent toremove dirt, grease etc whilst wet the surface shall be flatted down with asuitable abrasive and then rinsed down and allowed to dry. Minor areas ofdefective paint shall be removed by scraping back to a firm edge and theexposed surface touched up with primer as described and topped with putty.Where woodwork has been previously painted or polished and is to be newlypolished, the same shall be prepared with scraping, burring off or rubbing down.

8. BLINDS

8.1. Providing and fixing roller blinds with 38mm OD roll formed and lock seamedsteel of 0.5mm thickness suitably protected against corrosion.

8.2. Chain drive unit shall be of high engineering grade moulded plastic with steelsupport pin enclosed in a plastic housing and inserted into the control tubeend.it shall be driven by a ball chain pulley attached to a specially designedclutch mechanism, forming a continuous loop.

8.3. Control Ball chain shall be composed of braided nylon cord (2mm dia.) with highengineering grade plastic beads of 4.5mm diameter mounted co-axially on thecord with a pitch of 6.2 mm (C-T-C). It is used for raising or lowering the shade.

8.4. Bottom rail shall be aluminium tube, anodized with a diameter of 20mm andthickness of 0.5mm. The return end cap bracket shall incorporate a snap springdesign to facilitate easy installation and removal for maintenance activities. Thebracket shall be finished with a flush mounting cover on each side providing anaesthetic finish. The clutch should mount flush to the face of the bracket, whichminimizes the light gap between the shade and the window frame.

9. STANDARD WORKMANSHIP

9.1. To determine the acceptable standard of workmanship, the Contractor shallexecute a portion of the items of work as sample, for approval of the Architect,before taking up the actual execution of the particular item of work.

9.2. These samples, on approval of the Owner / Architect, shall be the guidingsample for execution of the particular item of work. Work not conforming to theapproved sample shall be rejected. Rates quoted for the items shall include forsuch preliminary work and shall not be paid for separately.

10. MATERIAL ORDER STATUS / RECEIPTS AT SITE

Page 18: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 18

10.1. The Contractor shall inform the Project Manager as regards the quantity &quality of the material received / available on site. The Project Manager shallcheck the material stock for quantity as well as quality. He may or may not giveany prior notice to the Contractor before such a check. The Contractor shallensure that the Project Manager has full access to his stores at all times.

11. MODE OF MEASUREMENT OF WORKS

11.1. The measurement of works carried out by the Contractor shall be taken inaccordance with procedure set forth in the Priced Schedule of Quantities /Specifications, notwithstanding any provision in the relevant standard Method ofMeasurement. In case of items not covered by the Schedule of Quantities /Specifications, measurements shall be taken in accordance with the relevant BISMode of Measurement.

11.2. Pre-measurements to the recorded for all dismantling items before starting ofthe works.

11.3. The Project Manager may from time to time advise the Contractor to measurethe work done and the Contractor shall forthwith attend or send a qualifiedrepresentative to assist the Project Manager in taking such measurements andcalculations and shall furnish all particulars or give all assistance required.

11.4. Should the Contractor not attend or neglect or omit to send such representativethen the measurements taken by the Project Manager shall be taken to becorrect measurements of the work.

11.5. The Contractor’s representative may note joint measurements along with theProject Manager.

11.6. All authorized extra work, omissions and all variations made without the ProjectManager knowledge, if subsequently sanctioned by him in writing shall beincluded in such measurements.

11.7. On completion of measurements of certain work up to a particular stage, theseshall be signed and dated by both the Project Manager and the Contractor as atoken of their acceptance. If the Contractor objects to any of the measurementrecorded by the Project Manager, a note to that effect shall be made in theMeasurement Book against the item objected to and such note shall be signedand dated by both parties.

12. DESCRIPTION OF WORK: HOW MEASURED MULTIPLYING FACTOR

12.1. Panelled, framed, ledged, braced Measured flat shall be measured as 1/3rd andshall not be measured as 1. Battened girthed) including Frames, edges, checksCleats, etc., shall be deemed to be including in the item.

12.2. Flush, part panelled and part Glazed or gaused – do -- 1 (for each side)

12.3. THE RATES QUOTED SHALL BE INCLUDING ALL WASTAGES. THEMEASUREMENT WILL BE TAKEN ON THE LAID AREA AND FOR THE FINISHEDPRODUCT ONLY.

SCOPE OF WORK IS DETAILED IN BILL OF QUANTITY (BOQ) & TENDERDRAWINGS (REFER FORM 1-D OF SCHEDULE OF PRICES). IN CASE OF ANY

Page 19: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 19

CONFLICT WITH THE GENERAL SPECIFICATION SPECIFIED ABOVE AND THE BILLOF QUANTITY(BOQ) AS PER FORM-1D, THE TECHNICAL SPECIFICATIONMENTIONED IN BILL OF QUANTITY ( FORM 1 D) SHALL PREVAIL.

Page 20: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 20

TECHNICAL SPECIFICATION FOR INTERIOR WORK -ELECTRICAL

Page 21: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 21

GENERAL SPECIFICATION FOR ELECTRICAL WORK- MEDIUM VOLTAGEDISTRIBUTION SYSTEM (Internal Lighting , Power wiring, Data &Voice Cabling)

1.0 GENERAL TERMS

1.1 The entire electrification work shall be carried out by licensed ElectricalContractors in accordance with these specifications without any extra cost.

1.2 For site supervision the contractor must depute an qualified electrical engineer.The contractor shall employ only experienced and licensed wiremen to do theelectrification work.

1.3 The work shall conform to relevant Indian Standard Specifications the I.E. Actsand Rules and the requirements of Local Electrical Authority.

1.4 When the installation is complete, the same shall be tested with the 500 /1000volts Megger in the presence of the Architect / Consultant and the results shallbe entered into the test certificate as per the format available with LocalElectrical Authority.

1.5 Contractor shall submit to the client 3 sets of test certificates for the installation.

1.6 The contractor shall carry out all civil works connected with the electrical job.The contractor shall repair and make good the damages caused by him to thecivil structure, HVAC and Fire protection System or other specified work whileexecuting the electrification work. The foundations for the panel board and forthe poles, grouting of frames in the wall, erection of D.B./switchboards in thewall/chasing the walls for embedding the conduits and boxes etc. are all to becarried out by the contractor including making good the damaged civil work.

1.7 The Contractor has to submit shop drawings for the Electrical Distribution Boardsand the conduit layout to the Architect/Consultants for their approval beforestarting the work. Also one set of approved sample of the materials have tobe kept at site.

1.8 The Architect/Consultant will issue the drawings to the Contractor for carryingout the work.

1.9 The Electrical Contractor ,his wiremen and supervisors shall be qualified andhave a valid licence while quoting as well as during the course of work.

2.0 REGULATION & STANDARDS

2.1 The system shall be governed by the requirements of IS: 732 and I.E. Rules andNEC. IS Standards and Codes applicable for medium voltage distribution is alsolisted in specification.

2.2 The definitions of terms shall be in accordance with IS: 732-1989 (IndianStandards Cods of Practice for Electrical Wiring), except for the definitions ofpoint, circuit, & sub-main wiring, which are defined in clauses hereunder.

2.3 The conventional signs & symbols for technical work shall be as shown indrawing.

Page 22: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 22

3.0 SCOPE OF WORKThe scope of work shall be generally as given in the Bill of Quantities of itemsand as mentioned below :-

A. Supply, Installation, Testing and Commissioning of the following :

i. Conduiting and wiring for lighting fixtures, Ceiling fans and Exhaustfans ,Computer & Telephone System in False Ceiling/woodenpartition walls/floor/columns/brick or concrete walls/M.S. Channel.

ii. All types of lighting fixtures, Ceiling fans and Exhaust fans.iii. Providing floor channels and Junction Boxes for drawing data cabling

and power wiring for work stations.

B. Testing and commissioning of the entire Electrical Installation includingTelephone system.

The contractor shall carry out and complete the work under this contractin every respect in confirming with the current rules and regulations of theNBC(NATIONAL BUILDING CODES), stipulations of the Indian StandardInstitution, and with the directions of and to the satisfaction of the owner. Thecontractor shall furnish all labour, material, appliances, equipment,transportation and incidentals necessary for providing, installing, testing andcommissioning of the whole electrical installation as specified herein and shownon drawings.

This also includes any materials, appliances, equipment and incidentalwork not specifically mentioned herein or noted on the drawings/documents asbeing furnished or installed but which are customary to make the installation inworking order. The work shall include all incidentals and jobs connected withElectrical installation such as earthing work and cutting chases/holes and makinggood the same and grouting etc.

NOTES:

i. All items of work under the contract shall be executed strictly in accordance with thedescription of the item in the Bill of Quantities, relevant drawings and Specificationsread in conjunction with the appropriate Indian Standard Specifications, IndianElectricity rules as amended up to date and Conditions of Contract.

ii. The rate for each item of work included in the Schedule of Quantities shall unlessexpressly stated otherwise, include cost of:

a. All materials, fixing materials, accessories, operations, appliances, tools, plant,equipment, transport, labour and incidentals required in preparation for, in thefull and entire execution and completion of the work called for in the item and asper specifications and drawings completely.

b. Wastage on materials and labour.

c. Loading, transporting, unloading, handling/double handling, hoisting to all levels,setting, fitting and fixing in position, protecting, disposal of debris and all otherlabour necessary in and for the full and entire execution and to fully complete thejob in accordance with contract documents, good practice and recognisedprinciples.

d. Liabilities, obligations and risks arising out of conditions of contract.

Page 23: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 23

e. In the event of conflict between schedule of quantities and other documentsincluding the specifications, the most stringent shall apply and the interpretationof the Chief Architect shall be final and binding.

iii. The Contractor shall be paid for the actual quantity of work executed by him inaccordance with the drawings at the contract rates.

iv. All errors in totaling the amount column and in carrying forward totals shall becorrected.

v. Unless otherwise stated all measurements shall be taken in accordance with IndianStandard Electrical Installation in building Method of Measurement IS 5908 latestrevisions/ additions.

vi. On the completion of the work the Contractor shall submit to the Owner layoutDrawings indicating the complete Electrical Installation as installed . These Drawingsshall in particular give the following information.

i. Run and size of conduit, location of inspection/outlet boxes.ii. Number and size of wires in each conduit.iii. Location of switches, outlets, DBs, Telephone, Call Bell & Music outlets etc.iv. Layout and particulars of mains and sub-mains and cable route etc.v. Schematic diagrams for the complete Electrical System.vi. Complete Earthing System with size of Earthing conductors.vii. Layout and particulars of the Telephone and Computer system.viii. Substation Equipments Layout.

4.0 POINT WIRING

4.1 A point (other than socket outlet point) shall include all work necessary incomplete wiring to the following outlets from the controlling switch or MCB. Thescope of wiring for a point shall however, include the wiring work necessary intapping from another point in the same distribution circuit.

4.2 Ceiling rose or connector (in the case of points for ceiling/ exhaust fan points,prewired light and call bells)

4.3 Ceiling rose (in case of pendants except stiff pendants).

4.4 Back plate (in case of stiff pendants).

4.5 Lamp holder (in case of goose neck type wall brackets, batten holders andfittings which are not prewired).

4.6 In case of call bell points, the words “controlling switch or MCB” shall be read as“from the ceiling rose meant for connection to bell push”.

4.7 Supplying and fixing/ drawing of cables in conduits including connections.

4.8 Supplying and fixing wood battens, bends, corners, fillers, tee-pieces etc.required for wiring on battens.

4.9 Metal switch boxes for control switches, regulators, sockets etc. recessed orsurface type, and

Page 24: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 24

4.9.1 Phenolic laminated sheet covers over the same for piano type switches.

4.9.2 Modular covers over the same for modular type switches and MCBs.

4.10 Supplying and fixing all accessories such as screws, clips, plugs, clamps etc. asspecified for securing, cables, battens, conduits etc. to walls, steel joists etc.

4.11 Supplying and fixing of bushed conduit or porcelain tubing for wiring to passthrough walls, floors, etc.

4.12 Supplying and fixing of joint and junction boxes.

4.13 Control switch piano type, modular type, MCB as specified in the BOQ.

4.14 Cutting holes in or through walls, taking up and re-fixing floor boards, notchingor drilling holes thorough joists and making good all disturbed work to match theexisting.

4.15 Shellac varnishing as specified to wood battens, wood blocks and other woodfittings and fixtures.

4.16 Pointing of battens and cables or surface conduits along with painting of walls.

4.17 Testing as specified.

5.0 MEASUREMENTS OF POINT WIRING

5.1 POINT WIRING (OTHER THAN SOCKET OUTLET POINT)

5.1.1 The measurement would be as specified in the Bill of Quantity i.e RMt or as perCPWD works manual.

5.1.2 No separate measurement shall be made for interconnections between points inthe same distribution circuits & for the circuit protective (loop earthing)conductors between metallic switch boxes.

5.2 POINT WIRING FOR SOCKET OUTLET POINTS.

5.2.1 The light plug 5A/ 6A & power plug 15A/ 16A points wiring shall be measured asspecified in the Bill of Quantity i.e RMt, from the respective tapping point of livecable viz switch box, another socket outlet points, or the sub distribution boardas the case may be upto the socket outlet.

5.2.2 The metal box with cover, switch/ MCB, socket outlet & other accessories shallbe measured shall be measured as specified in the Bill of Quantity.

5.2.3 The power point outlet may be 15A/ 15A or 16A/ 16A six/ three pin socketoutlet, where so specified in the tender documents.

5.3 GROUP CONTROL/ LOOP POINTS WIRING

5.3.1 In the case of points with more than one point controlled by the same switch,the same point shall be measured in parts i.e.

5.3.2 From the switch to the first point outlet as one point and

Page 25: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 25

5.3.3 For the subsequent points, shall be treated as separate point(s).

5.3.4 No recovery shall be made for non-provision of more than one switch/ MCB. Insuch cases.

5.4 TWIN CONTROL LIGHT POINTS WIRING

5.4.1 A light point controlled by 2 Nos. of two way switches shall be measured as twoseparate points from the fitting to switches on either side.

5.4.2 No recovery shall be made for non-provision of more than one ceiling rose orconnector is such cases.

6.0 CIRCUIT WIRING , SUB–MAIN WIRING AND ITS MEASUREMENT

6.1 Circuit wiring shall mean the wiring from the distribution board upto the tappingto the nearest first point of the distribution circuit viz upto the nearest switchbox.

6.2 Sub-main wiring shall mean wiring form one main/ distribution switch board toanother.

6.3 MEASUREMENT OF CIRCUIT & SUB-MAIN WIRING.

6.3.1 Circuit & Sub-Main wiring shall be measured on linear basis along the run of thewiring or as mentioned in BOQ. The measurement shall include all lengths fromend to end of conduit or PVC casting capping as the case may be, exclusive ofinterconnection inside switch board etc. The increase on account of diversion orslackness shall not be included in the measurement.

6.3.2 The length of circuit wiring with two wires shall be measured from thedistribution board to the first nearest switch box in the circuit irrespective ofwhether the neutral conductor is taken to the switch box or not.

6.3.3 When wires of different circuits are grouped in a single conduit, the same shallbe measured to the nearest switch box in the circuit irrespective of whether theneutral conductor is taken to the switch box or not.

6.3.4 When circuit wires and wires of point wiring are run in the same conduit, circuitwiring shall be measured on linear basis depending on the actual number ofsizes of wires run in the existing conduit.

6.3.5 Protective (loop earthing) conductors which are run along the circuit wiring andthe sub-main wiring shall be measured on linear basis and paid for separately.

7.0 6 & 16 AMP SWITCH SOCKET OUTLET - MODULAR RANGE

7.1 Switch socket outlet on lighting circuit shall be of 5 pin 6 Amp outlet and shallhave safety shutters. The switch shall be of rocker mechanism type with silver

Page 26: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 26

safety contact. Switch and socket outlet shall be separate unit in modular rangeand shall be plate type and of white finish. Switch shall be indicator type.

8.0 LIGHTING FIXTURES & FANS

8.1 Luminaire shall be supplied as per the design specified in the Schedule ofQuantities. Luminaire shall be complete in all respects with basic mountingchannel, lamp holders, starter with holder, copper/ electronic ballast, connectorblock, internal wiring and decorative attachments, if any.

8.2 The light fixtures and fans shall be assembled and installed in position (both forsurface mounted and recessed version) complete and ready for service inaccordance with the detailed drawings, manufacturer’s instructions and to thesatisfaction of the Engineer-In-Charge.

8.3 Light fixtures in general shall be recessed type in false ceiling or surfacemounted on soffit of slab or wall with rawl plugs. Luminaries shall be installed asspecified on the drawings. Wherever luminaires are fixed on the false ceiling,suitable supporting and fixture arrangements independent of the frame, work offalse ceiling shall be provided.

8.4 Suspended type fluorescent light fixture shall be fixed to circular junction boxwith a metallic ball and socket arrangement and comprising of suspension pipesetc., for installing the luminaries.

8.5 Fixtures shall be suspended true to alignment plumb level and capable ofresisting all lateral and vertical forces and shall be fixed as required. It is theduty of the Contractor to make these provisions at the appropriate stage &locations shown on the drawings.

8.6 All the materials used in the construction of luminaries shall be of such quality,design and construction that will provide adequate protection in normal use,against mechanical, electric failure/ faults and exposure to the risk of injury orelectric shock & shall withstand the effect of exposure to atmosphere.

8.7 Erection of fixtures shall include assembling of all components of the fixturessuch as chokes, condensers, starters, ignitor, decorative attachments, etc.

8.8 Bulkhead fittings shall be of cast iron/cast aluminum body suitably painted whiteinside and grey outside complete with heat resistant glass cover, lamp holderand wire guard suitable for 100 watts incandescent lamp.

9.0 LAMPS, LAMP HOLDERS, CEILING ROSES & BALLASTS

9.1 Fluorescent lamps shall conform to IS in all respects. Fluorescent lamps shall beof bi-pin pattern. The colour of the light shall be white or cool day light, asrequired. Unless otherwise specified. The lamps shall be of required wattage asper approved lighting scheme.

Page 27: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 27

9.2 Accessories for light outlets such as lamp holders, ceiling roses etc. shall be inconformity with requirements of relevant IS Specifications. Only approved makeof accessories shall be supplied.

9.3 All ballast in general shall be copper wound, electronic and shall be silent inoperation. Ballast shall have a long life and shall be highly reliable.

9.4 For fluorescent lamp fixtures low loss ballasts shall be used unless otherwisestated.

9.5 Ballasts shall be suitable for 240V, 50 Hz AC supply

10.0 TESTING & INSTALLATION

10.1 Testing & Installation shall be as per IS: 732-1963.

10.2 The insulation resistance measured as above shall not be less than 50 divided bythe number of points on the circuits provided that the whole installation shall berequired to have an insulation resistance greater than one mega-ohm.

10.3 Control rheostate, heating and power appliance and electrical signs may, ifrequired, be disconnected from the circuit during the test, but in event theinsulation resistance between the case or frame work and all live parts of eachrheostat appliance and sign shall not be less than that specified in the relevantIndian Standard.

10.4 Specification or where there are no such specifications shall not be less than halfmeg-ohm.

10.5 The insulation resistance shall also be measured between all conductorsconnected to one pole or phase conductor of the supply and all the conductorsconnected to the middle wire or the neutral or to the other pole or phaseconductors of the supply and its value shall not be less than as specified in thistender document.

10.6 On completion of an electrical installation (or an extension to an installation) acertificate shall be furnished by the contractor, counter signed by the supervisorunder whose direct supervision the work has been carried out.

10.7 TESTING OF EARTH CONTINUITY PATH

10.7.1 The earth continuity conductor including metal conduits and metallic enclosuresor in all cases shall be tested for electric continuity and the electrical resistanceof the same along with the earthing lead but excluding any added resistance orearth leakage circuit breaker measured from the connection with the earthelectrodes to any points in the earth continuity conductor in the completeinstallation shall not exceed on mega-ohm.

Page 28: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 28

10.7.2 Before a completed installation or an extension to an existing installation is putinto service it shall be tested as per IS-732. The following tests shall bespecifically carried out for all lighting installations:

10.7.2.1 Insulation Resistance.

10.7.2.2 Testing of earth continuity path.

10.7.2.3 Testing of polarity of single pole switches.

10.8 LIGHTING CIRCUITS

10.8.1 All switches ‘on’ and consuming devices in circuit, both polls connected together,to obtain resistance to earth.

10.8.2 Between polls with lamps and other consuming devices remove and switches ‘on’

10.8.3 With lamps and other consuming devices in position but switches ‘off’.

10.9 RESISTANCE OF EARTH

10.9.1 The resistance of earthing system shall not exceed one ohm. Earth testingresults to be got approved by the Inspecting Authority.

11.0 WIRING SPECIFICATION :

11.1 SYSTEM OF WIRING: The system of wiring shall consist of single/multi core PVCinsulated FRLS copper conductor wires in non-metallic PVC conduits/ metallicM.S. conduits as called for in the BOQ. All conduits shall be on thesurface,(supported from the Ceiling), in the False Ceiling and concealed in otherareas where RCC slab is provided unless otherwise called for in the drawings. AllDown conduits shall be concealed unless otherwise called for.

11.2 Prior to laying of conduits, the Contractor shall get approved the conduit layoutindicating the route of conduit, number and size of conduits, location ofjunction/ inspection/pull boxes, size and location of switch boxes, point outletboxes and other details. These conduit layouts shall be got approved by theConsultant and then only conduit layout should be started. Any modification orsuggestions shall be approved by the Consultant before the laying of conduits.

11.3 MATERIALS:M.S. conduits shall conform to Indian Standards IS : 1653 - 1964 -Specification for Rigid Steel conduits for Electrical wiring with the latestamendments.

11.4 M.S. CONDUITS: M.S. conduits shall be solid drawn or lap welded conduits.Stove enameled inside and outside with minimum wall thickness of 1.6 mm for

Page 29: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 29

conduits upto 25 mm diameter and 2.0 mm wall thickness for conduits 32 mmdiameter and above.

11.5 PVC conduits to be used for concealed work for all systems except Fire Alarm &Computer system where M.S. conduits shall be used. PVC conduits shall conformto Indian Standards IS : 9537(Part-3)-1983 -Specification for conduits forElectrical Installation (Part-I) General Requirements.

11.6 PVC conduits shall be rigid, unplasticised, heavy gauge having 1.8 mm wallthickness upto 20 mm diameter and 2.0 mm wall thickness for all sizes above 20mm diameter. Minimum size of conduit shall be 20 mm dia. Minimum size ofconduit for Power point wiring shall be 25 mm dia. The conduits shall bedelivered to the site of construction in original bundles and each length ofconduit shall bear the label of the manufacturer. The number of insulatedcopper wires that may be drawn into the conduits of various sizes are givenbelow and the fill shall not exceed 40% the maximum permissible number of650/1100 volts grade single/multi core PVC insulated copper conductor wires ofdifferent sizes, that may be drawn into rigid metallic or non-metallic conduits.

SIZE OF WIRE SIZE OF CONDUITS (MM)————————————————————————————————-Nominal cross- 20 25 32 40 50 nominal dia in mmSectional areaof wires in sq. mm ( Maximum number of wires )————————————————————————————————-

1.5 5 6 18 - -2.5 3 4 10 - -4.0 2 3 5 10 -6.0 - 4 6 8 -10.0 - - 3 4 -16.0 - - - 3 525.0 - - - 2 3

————————————————————————————————-

11.7 PVC CONDUIT ACCESSORIES & CONNECTIONS: The accessories used for PVCconduits shall conform to Indian Standards IS : 3419-1988-(Specification forfittings for non-metallic conduits).PVC conduits shall be joined by means ofscrewed or plain couplers. Where there are long runs of straight conduits,inspection boxes shall be provided at intervals as approved by the consultant.The threads of the pipe and sockets shall be free from grease and oil. It shall bethoroughly cleaned before making the screwed/plain joints. Proper jointingmaterials as recommended by manufacturers shall be used for jointing of PVCpipes. Use PVC couplers and connectors for PVC pipe connections and termina-tions in boxes. All the joints shall be fully water tight. Junction boxes andrunning joints shall be provided at suitable places to allow for subsequentextensions if any, without undue dismantling of conduit system. As far aspossible diagonal run of conduits shall be avoided. Junction between conduit and

Page 30: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 30

adapter boxes, back outlet boxes, switch boxes and the like must be providedwith entry spouts and smooth PVC bushes. Joints between conduit and iron cladDistribution Boards or control gear shall be effected by means of conduitcouplers into each of which will be coupled smooth PVC bush from the inside ofbox or case. Conduit system shall be erect and straight as far as possible. Alljointing methods shall be subject to the approval of the consultant.

11.8 BENDS IN CONDUITS: Where necessary bends or diversions may be achievedby means of bends and or circular inspection boxes with adequate and suitableinlet and outlet screwed joints. In case of recessed system each junction boxshall be provided with a cover properly secured and flush with the finished wallsurface, so that the conductors inside the conduits are easily accessible. No bendshall have a radius of less than 2.5 times the outside diameter of the conduit.Conduits shall be cold bend by means of a Bending spring available with themanufacturers. In case it is not available then Heat may be used to soften thePVC conduits, by filling sand in the pipe. Use of PVC conduit in places whereambient temperature is 60 degrees or above is prohibited. PVC Solvent shall beused for joints between conduits, conduits & Junction box etc. PVC checknutsand bushes shall be used for joining conduit with outlet boxes. PVC Closuresshall be provided on unused mouths of Junction boxes.

Separate conduits shall be provided for the following system.

i) Lights, Ceiling fans, Exhaust fans & 5A Light sockets.ii) Power sockets & A/C outletsiii) Telephone Systemiv) Television, Computer & Music systemv) Emergency System.vi) Public Address Systemvii) Fire Alarm System.

Separate switchboards/outlets shall be provided for the following system.

i) Lights, Ceiling fans, Exhaust fans & 5A Light sockets.ii) Power sockets & A/C outletsiii) Telephone Systemiv) Television, Computer & Music systemv) Emergency System.vi) Public Address Systemvii) Fire Alarm system .

11.9 FIXING CONDUITS: Conduits and junction boxes shall be kept in position andproper holdfasts shall be provided. Conduits shall be so arranged as to facilitateeasy drawing of wires through them. Adequate junction boxes of approvedshape and size shall be provided. All conduits shall be installed so as to avoidsteam and hot water pipes. After the conduits, junction boxes, outlet boxes &switch boxes are installed in position their outlets shall be properly plugged sothat water, mortar, insects or any other foreign matter does not enter into theconduit system. Exposed conduits shall be fixed by means of spacer bar/ saddles

Page 31: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 31

at intervals of not more than 600 mm in normal run and 500 mm from bothsides of fitting or accessories. The saddles shall be of 3 mm x 19 mm mild steelflat, properly treated with primer and painted, securely fixed to support bymeans of nuts and bolts/rawl bolts and MS screws as required.

Conduits shall be laid in a neat and organised manner as directed and approvedby the Consultant. Conduit runs shall be planned so as not to conflict with anyother service pipe lines/ducts. Where exposed conduits are suspended from thestructure they shall be clamped firmly and rigidly to hangers of design to beapproved by the Architect. Where hangers are to be anchored to reinforcedconcrete appropriate inserts and necessary devices for their fixing shall beprovided at the time of fixing.

Making holes or openings in the concrete will generally not be allowed. In case itis unavoidable prior permission of the Consultant shall be obtained. Conduitsshall be fixed in the chase by means of staples not more than 600 mm apart andthe chase filled with cement mortar 1 : 4 . Cutting of horizontal chases in walls isprohibited.

11.10 PROTECTION OF CONDUITS : To minimize condensation or sweating inside theconduit pipes all outlets of conduit system shall be adequately ventilated asdirected and approved by the Consultant. All screwed and socketed connectionsshall be adequately made fully water tight by the use of proper jointing materialsi.e. Tropolin for PVC conduits & white lead for metal conduits.

11.11 M.S.CONDUIT ACCESSORIES & CONNECTIONS:

11.11.1 The accessories used for M.S. conduits shall conform to Indian Standards IS :3837-1966-(Specification for fittings for Rigid steel conduits with the latestamendments. M.S. conduits shall be joined by means of screwed or plaincouplers. Where there are long runs of straight conduits, inspection boxes shallbe provided at intervals as approved by the Consultant. The threads of the pipeand sockets shall be free from grease and oil. It shall be thoroughly cleanedbefore making the screwed/plain joints.

11.11.2 Proper jointing and Cleaning materials as recommended by manufacturers shallbe used for jointing and cleaning of M.S. pipes. Use M.S. couplers andconnectors for M.S.pipe connections and terminations in boxes. All the jointsshall be fully water tight. Junction boxes and running joints shall be provided atsuitable places to allow for subsequent extensions if any, without unduedismantling of conduit system. As far as possible diagonal run of conduits shallbe avoided. Junction between conduit and adapter boxes, back outlet boxes,switch boxes and the like must be provided with entry spouts and smooth M.S.bushes and M.S. Checknuts. Joints between conduit and iron clad DistributionBoards or control gear shall be effected by means of conduit couplers into eachof which will be coupled smooth M.S. bush from the inside of box or case.Conduit system shall be erect and straight as far as possible. All jointingmethods shall be subject to the approval of the Consultant.

Page 32: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 32

11.11.3 M.S. CONDUIT CONNECTIONS:

11.11.3.1 Conduit connections for MS conduits shall be screwed metal to metal and bepainted with one coat of self etching zinc chromate primer and two coats ofenamel paint. The threads and sockets shall be free from grease and oil.Connections between screwed conduit and sheet metal boxes shall be by meansof a brass hexagon smooth bore bush, fixed inside the box. Checknuts to beprovided on inside and outside of box and connected through a coupler to theconduit or as directed by the Consultant. The joints in the conduits shall be freeof burrs to avoid damage to insulation of conductors while pulling them throughthe conduits. Connections between PVC and MS conduits shall be through ajunction box. Direct connection between PVC and MS conduits is not allowed.

11.11.4 FAN BOX DETAILS

11.11.5 The Fan Box shall be 100 mm x 100 mm x 75 mm deep, M.S. box made of 2mmthick M.S. sheet, having 12 mm dia M.S. rod, bend at centre to support the fan,top screwed cover etc. as per the approval of the Architect/Consultants.

12.0 SWITCH-OUTLET BOXES AND JUNCTION BOXES

12.1 All Boxes shall conform to Indian Standards IS : 5133(Part-1)-1969 (Specificationfor boxes for enclosure of Electrical accessories) with the latest amendments. Alloutlet boxes for switches, sockets & other receptacles shall be fabricated from1.6mm thick mild steel sheets duly painted with rust proof paint (zincpassivated) as called for, having smooth external & internal surfaces to truefinish. Junction boxes and outlet boxes in contact with earth or installed in areasexposed to the weather shall be of 2mm thick mild steel and painted. Wherecalled for, outlet boxes for receiving switches, telephone outlets T.V. outlets,power plugs etc. shall be fabricated to proved shape and size to suit the coverplates of approved make for different utilities. The cover plates shall be of bestquality Hylam sheets or ISI grade Urea Formaldehyde Thermosetting insulatingmaterial which shall be both mechanically strong and fire retardant, as approvedby the Consultant. Proper supports shall be provided in the outlet boxes to fixthe cover plates of switches as required. Separate screwed earth terminal shallbe provided inside the box for earthing purpose.

12.2 All boxes shall have adequate number of knockout holes of required diameter forconduit entry. Where called for outlet boxes for receiving switches and fanregulators in one box, shall be fabricated to approved shape and size to accom-modate fan regulators and switches to be fixed on grid plates. These boxesshall be covered with Hylam sheets or ISI grade Urea FormaldehydeThermosetting insulating material which shall be both mechanically strong andfire retardant. All junction boxes, pull boxes and outlet boxes shall be providedwith sheet cover Urea Formaldehyde Thermosetting insulating material. The boxcover shall be secured to the box with adequate number of round head brassscrews of approved make.

Page 33: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 33

12.3 Outlets exposed to the weather shall be fully weather tight, complete withrubber gasketed covers, glass where used shall be fully heat resistant for theduty. The outlet boxes shall be painted with two coats of bitumastic paintbefore they are fixed in position. All Outlet boxes fixed in concrete/recessed inwall shall be of a minimum depth of 55mm.

12.4 INSPECTION BOXES: Rust proof (Zinc passivated) inspection boxes of 1.6mmthick mild steel sheet and of required size, having smooth external and internalfinish shall be provided to permit periodical inspection and to facilitate removaland replacement of wires when required. Inspection boxes shall be mountedflush with ceiling/walls finished surface and shall be provided with screwedcovers of Urea Formaldehyde Thermosetting insulating material sheet coversecured to the box with brass screws. Adequate holes shall be provided forventilation in the inspection box covers.

12.5 TELEPHONE SYSTEM: Conduits, junction boxes, draw boxes, outlet boxes andcovers to boxes for telephone system shall be as described under relevantclauses elsewhere in these specifications. Conduits for telephone system shallbe at least 150 mm away from the electrical conduits. The conduits fortelephone wiring shall be of specified size and shall be terminated at outlets asindicated on the drawings. Telephone system conduits shall have 2 mmdiameter galvanized steel pull wires installed. Necessary Junction boxes to beprovided for easy drawing of the Telephone wires from each unit to theTelephone Tag Box and from the Tag Box to the open ground.

12.6 T.V. & COMPUTER SYSTEM: Conduits junction boxes, draw boxes, outlet boxesand covers to boxes for T.V. & Computer system shall be as described underrelevant clauses elsewhere in these specifications. Conduits for T.V. & Computersystem shall be at least 150mm away from the electrical conduits. The conduitsfor T.V. & Computer wiring shall be of specified size and shall be terminated atoutlets as indicated on the drawings. T.V. & Computer system conduits shallhave 2mm diameter galvanized steel pull wires installed. Necessary Junctionboxes to be provided for easy drawing of the Television & Computer wires fromeach unit to the Junction Box and from the Junction Box to the open ground.

13.0 CONDUCTORS

13.1 PVC insulated multistrand copper conductor wires of 1100 Volts grade shall beused for three phase distribution and PVC insulated multistrand copperconductor wires of 1100 V grade shall also be used for Single phase distributionand shall conform to IS : 694 -1964 with the latest amendments and shall beISI marked.

13.2 BUNCHING OF WIRES

13.2.1 Wires carrying current shall be so bunched in the conduit that the outgoing andreturn wires are drawn into the same conduit. Wires originating from twodifferent phases shall not be run in the same conduit.

Page 34: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 34

13.3 DRAWING OF CONDUCTORS

13.3.1 The drawing and jointing of copper conductor wires shall be executed with dueregard to the following precautions, while drawing insulated wires into theconduits. Care shall be taken to avoid scratches and kinks which causebreakage of conductors. There shall be no sharp bends. Insulation shall beshaved off for a length of 15mm at the end of wire like sharpening of a penciland it shall not be removed by cutting it square or ringing.

13.3.2 PVC insulated copper conductor wire ends before connection shall be properlysoldered (at least 15mm length) with special Cu solder for copper conductor orshall be properly crimped with copper lugs/sockets as the case may be. Strandsof wires shall not be out for connecting to the terminals. All strands of wiresshall be soldered at the end before connection. The connecting brass-screwsshall have flat ends. All looped joints shall be soldered and connected throughterminal block/connectors. The pressure applied to tighten terminal screws shallbe just adequate, neither too much nor too less. Conductors having nominalcross sectional area exceeding 6 Sq mm shall always be provided with cablesockets.

13.3.3 At all bolted terminals, brass flat washer of large area and approved steel springwashers shall be used. Brass nuts and bolts shall be used for all connections.

13.3.4 Only certified wiremen and cable jointers shall be employed to do jointing work.All wire shall bear the manufacturer’s label and the voltage grade at one meterintervals for the full length of coil, and shall be brought to site in new andoriginal packages.

13.3.5 The sub-circuit wiring for points shall be carried out in looping system and nojoint shall be allowed in the length of the conductors. No wire shall be drawninto any conduit, until all work of any nature, that may cause injury to wire iscompleted. Care shall be taken in pulling the wires so that no damage occurs tothe insulation of the wire. Before the wires are drawn into the conduits theconduits shall be thoroughly cleared of moisture, dust, and dirt or any otherobstruction by Drawing dry cloth through the conduits. The minimum size ofPVC insulated stranded copper conductor wire for all sub circuit wiring for lights,exhaust fans, ceiling fan and 5A Light sockets points shall be 1.5 Sq mm. Incase of power circuit not more than two 15 Amp power outlets shall be groupedin one circuit, wiring for the first power outlet shall be carried out with PVCinsulated 6.0 sq mm copper conductor wires. Wiring for the second power out-let shall be carried with PVC insulated 4.0 sq mm copper conductor wires. Allpower outlets shall be connected with 4.0 sq mm PVC insulated copperconductor wires to the earth terminal of outlet. Separate circuit shall run withPVC insulated 4.0 sq mm copper conductor wires for water heaters, kitchenequipment, window Air conditioners and similar outlets at locations as shown ondrawings.

Page 35: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 35

13.3.6 The minimum size of wire from final distribution board to first tapping point inthe circuit shall be 2.5 Sq mm. PVC insulated stranded copper conductor wires.Circuit shall not have more than a total of 8 points of fans, 5A Light sockets andLight points and its load shall not exceed 800 watts. Not more than two powercircuits shall be drawn through the same conduit. Separate earth wire shall runfor each circuit. In case two circuits of the same phase are running in the sameconduit then a common earth wire is permissible. The size of earth wire for allthe light points, ceiling fans, exhaust fans , light sockets, outlet boxes etc. shallbe 1.5 sq mm PVC insulated copper conductor wires.

13.4 JOINTS

13.4.1 All joints shall be made at main switches, distribution boards, socket outlets,lighting outlets and switch boxes only. No joints shall be made inside conduitsand junction boxes. Conductors shall be continuous from outlet to outlet. Jointswhere unavoidable, due to any specified reasons, prior permission in writingshall be obtained from the Consultant before making such connections.

13.5 LOAD BALANCING

13.5.1 Balancing of circuits in three phase installation shall be planned before thecommencement of wiring, shall be got approved by the Consultant and shall bestrictly adhered to.

13.6 COLOUR CODE OF CONDUCTORS

13.6.1 Colour code shall be maintained for the entire wiring installation; red, yellow,blue for three phases and “off” circuit black for neutral and green for earth (orbare earth wire)

13.6.2 Telephone Multicore cables shall be of approved make and shall conform tofollowing specifications:

i) Type of conductor ….. Electrolytic Annealed Tinned Cu conductor (ATC)ii) Diameter of Conductor ... 0.61 mm dia uniform (minimum size)ii) Weight of conductor .... 2.52 Kg/Km minimum.iii) Resistance of conductor at 20 degree... 60 Ohms/Km,iv) Radial Thickness of PVC insulation...0.3mm + 0.05mm uniformvi) Radious Thickness of PVC sheathing ... 1.2mm uniform + 0.2mmvii) Overall diameter of insulated conductor.. 1.2mm uniformviii)High voltage Test. Able to withstand upto 500 volts D.C. up to 12

hours immersion in water.

14.0 EARTHING

14.1 All the non-current metal parts of electrical installation shall be earthed properly.All metal conduits, trunking, cable sheaths, switchgear, outlet boxes, distributionboards, light fittings, fans and all other parts made of metal or conductive

Page 36: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 36

material shall be bonded together and connected by means of specified earthingsystem.

14.2 All earthing will be in conformity with the relevant provision of Rules 33 and 61of the Indian Electricity Rules 1956 and Indian Standard Specifications IS:3043-1987 with latest amendments.

14.3 EARTHING CONDUCTORS

14.3.1 All earthing conductors shall be of high conductivity electrolytic copper of 99 %purity and shall be protected against mechanical injury or corrosion.

14.4 SIZING OF EARTHING CONDUCTORS

14.4.1 The cross sectional area of copper earthing conductor shall be same as theactive conductor for sizes of active copper conductor upto 4.0 sqmm and shallbe half the size for 16 sq mm active copper conductor and above. All fixtures,fans, outlet boxes and junction boxes shall be earthed with 1.5 sqmm PVCInsulated copper conductor wires. All power sockets and single phase A/C unitsshall be earthed with 4.0 PVC Insulated copper conductor wires. All Three phaseFinal Distribution Boards shall be earthed with 2 nos 4 mm dia bare copperconductor wires. The sizes of the earth continuity conductors should not be lessthan half of the largest current carrying conductors.

14.4.2 The Sub-Distribution Board shall be earthed to 2 nos 600mm x 600mm x 3mmcopper plate earthing stations through 25m x 3 mm copper strips.

14.5 CONNECTION OF EARTHING CONDUCTORS

14.5.1 Main earthing conductors shall be taken from the earth connections at the mainswitchboards to an earth electrode with which the connection is to be made.Submain earthing conductors shall run from the main switchboard to the sub-distribution boards. Final distribution boards earthing conductors shall run fromsub-distribution boards.

14.6 PROHIBITED CONNECTIONS

14.6.1 Neutral conductor, sprinkler pipes, or pipes conveying gas, water, orinflammable liquid, structural steel work, metallic enclosures or cables andconductors, metallic conduits and lightning protection system conductors shallnot be used as a means of earthing an installation or even as a link in anearthing system. The electrical resistance of metallic enclosures for cables andconductors measured between earth connections at the main switchboard andany other point on the completed installation shall be low enough to permit thepassage of current necessary to operate fuse or circuit breakers and shall notexceed 1 ohm.

14.7 PROTECTION FROM CORROSION

Page 37: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 37

14.7.1 Connections between copper and galvanised equipment shall be made onvertical face and protected with paint and grease. Galvanised fixing clamps shallnot be used for fixing earth conductors. Only copper fixing clamps shall be usedfor fixing earth conductors. When there is evidence that the soil is aggressive tocopper, buried earthing conductors shall be protected by suitable serving andsheathing.

14.8 EARTHING STATION

14.8.1 Plate Electrode Earthing : Earthing electrode shall consist of a tinned copperplate not less than 300mm x 300mm x 3mm thick as called for in the Schedule.The plate electrode shall be buried as far as practicable below permanentmoisture level but in any case not less than 4.2 meters below ground level.Wherever possible earth electrodes shall be located as near the water tap, waterdrain or a down take pipe as possible. Earth electrodes shall not be installed inproximity to a metal fence. It shall be kept clear of the buildings foundationsand in no case shall it be nearer than 2 meters from the outer face of the wall.The earth plate shall be set vertically and surrounded with 150mm thick layer ofcharcoal, dust and salt mixture. 20mm GI pipe shall run from the top edge ofthe plate to the ground level. The top of the pipe shall be provided with afunnel and a mesh for watering the earth through a pipe. The funnel over theGI Pipe shall be housed in a masonry chamber, approximately 300mm x 300mmx 300mm deep. The masonry chamber shall be provided with a cast iron coverresting over a GI frame embedded in masonry. Refer Sketch for additionaldetails.

14.9 EARTH CONNECTION

14.9.1 All metal clad switches and other equipment carrying single phase current, shallbe connected to earth by a single connection. All metal clad switches carryingmedium voltage and high voltage shall be connected with earth by two separateand distinct connections. The earthing conductors inside the building whereverexposed shall be properly protected from mechanical injury by running the samein GI Pipe of adequate size.

14.9.2 Earthing conductors outside the building shall be laid 600mm below the finishedground level. The over lapping in copper strips at joints where required, shall beminimum 75mm. The joints shall be riveted and brazed with copper rivets andgreased in approved manner. Sweated lugs of adequate capacity and size shallbe used for all termination of wires above 1 Sqmm size and bare copper wireabove 2.0mm dia. Lugs shall be bolted to the equipment body after the metalbody is cleaned of paint and other oily substance and properly tinned. The earthwires entering the Final Distribution Boards shall be terminated with coppersockets crimped to its ends and tightened to the terminal with the help of flatend brass screws.

14.10 EARTH RESISTANCE

Page 38: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 38

14.10.1 The earth resistivity of the soil where the earthing stations are located shall besubmitted to the Consultant before the earthing work starts and get the approvalof the Consultant/Owner. If the earth resistance is too high and multipleelectrode earthing does/not give adequate low resistance to earth, than the soilresistivity immediately surrounding the earth electrodes shall be reduced byadding sodium chloride, calcium chloride, sodium carbonate, copper sulphate,salt and soft coke or charcoal in suitable proportions as directed by theconsultants.

14.11 RESISTANCE TO EARTH

14.11.1 The resistance of each earth system shall not exceed 1.0 ohm in the case ofMedium Voltage system and 0.5 ohm in the case of High Voltage system.

15.0 TESTING

15.1 On completion of the work the entire installation shall be subject to followingtests:a) Wiring Continuity Testb) Insulation Resistance Testc) Earth Continuity Testd) Earth Resistivity Test

15.2 Besides the above any other test specified by the local Authority shall also becarried out.

15.3 All tested and calibrated instruments for testing, labour, materials andincidentals necessary to conduct the above tests shall be provided by theContractor at his own cost.

15.4 TESTING OF WIRING

15.4.1 All wiring systems shall be tested for continuity of circuits, short circuits andearthing after wiring is complete and before energising. The Test Certificates forthe complete wiring shall be submitted in the Format and the Total ElectricalInstallation shall be got approved by the Electrical Inspector.

15.5 INSULATION RESISTANCE TEST

15.5.1 The insulation resistance shall be measured by applying between earth and thewhole system of conductors, or any section thereof with all fuses in place and allswitches closed (except in concentric wiring) all lamps in position of both polesof the installation , otherwise electrically connected together, a direct currentpressure of not less than twice the working pressure(provided that it does notexceed 660 volts for medium voltage circuits) be applied. Where the supply isderived from A.C. three phase system, the neutral pole of which is connected toearth, either direct or through added resistance, pressure shall be deemed to bethat which is maintained between the phase conductor and the neutral. Theinsulation resistance measured as above shall not be less than 50 divided by the

Page 39: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 39

number of points on the circuit provided that the whole installation shall not berequired to have an insulation resistance greater than one mega ohm. Theinsulation resistance shall not be measured between all conductors connected toone phase conductor of the supply and all the conductors connected to themiddle wire or to the neutral or to the other phase conductors of the supply.Such a test shall be carried out after removing all metallic connections betweenthe two poles of the installation and in these circumstances the insulationresistance between conductors of installation shall not be less than that specifiedabove.

15.5.2 The insulation resistance between the case of frame work of housing and powerappliances, and all live parts of each appliance shall not be less than thatspecified in the relevant Indian Standard Specifications or where there is no suchspecification shall not be less than half a mega ohm.

15.6 TESTING OF POLARITY OF NON-LINKED SINGLE POLE SWITCHES

15.6.1 In a two wire installation a test shall be made to verify that all non-linked singlepole switches have been fitted in the same conductor through out, and suchconductor shall be labeled or marked for connection to an outer or phaseconductor or to the non-earthed conductor of the supply. In the three or fourwire installation a test shall be made to verify that every non-linked single Poleswitch is fitted in a conductor to one of the outer or phase conductor of thesupply. The entire electrical installation shall be subject to the final acceptanceof the Consultant as well as the local authorities.

15.7 EARTH RESISTIVITY TEST

15.7.1 Earth resistivity test shall be carried out in accordance with Indian Standard codeof practice for earthing IS:3043:1987. All tests shall be carried out in thepresence of the Consultant/Owner.

15.8 TEST CERTIFICATES

15.8.1 The Electrical Installation shall be tested as per relevant Indian Standards andTest Certificate to this effect shall be submitted to the Owner. The Contractorhas to get the Total Electrical Installation approved by the Electrical Inspectorand the permission to energise the same shall be submitted to the Owner.

16.0 SAFETY REQUIREMENTS

16.1 Safety provisions shall be generally in conformity with the relevant IndianStandards and I.E. Rules and Regulations. In particular the following items shallbe provided.

(a) Insulation Mats

Insulation Mats conforming to IS : 5424-1969 shall be provided in front of mainswitch boards and other control equipment as specified.

Page 40: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 40

(b) First Aid Charts and First Aid Box

Charts (one in English, one in Hindi, one in Regional language), displayingmethods of giving artificial respiration to a recipient of electrical shock shall beprominently provided at appropriate place. Standard First Aid Boxes containingmaterials as prescribed by St. John Ambulance brigade or Indian Red Cross2should be provided in each sub-station.

2(c) Danger Plate

Danger plates shall be provided on HV and MV equipments. MV danger noticeplate shall be 200mm x 150mm made of mild steel atleast 2mm thick vitreousenameled white on both sides and with inscriptions in signal red colour onfront side as required.

(d) Caution Board

Necessary number of caution boards as “Man on Line” “Don’t switch on’ etc.shall be available in the sub-station.

(h) Key BoardA key board of required size shall be provided at a proper place containingcastel key, and all other keys of sub-station and allied areas.

17.0 FIRE DETECTION AND ALARM SYSTEM

17.1 The contractor’s scope shall be removal and re-installation of smoke detectors,sprinklers, response indicators and temperature heat detectors ( Fire sensors)connecting, testing and commissioning to the existing conventional type fire detectionand alarm system.

17.2 In case of any damage to the existing sensors and detectors , contractor shall supplythe sensors & detectors as per the approved make.

SCOPE OF WORK IS DETAILED IN BILL OF QUANTITY (BOQ) & TENDERDRAWINGS (REFER FORM 1-D OF SCHEDULE OF PRICES). IN CASE OF ANYCONFLICT WITH THE GENERAL SPECIFICATION SPECIFIED ABOVE AND THE BILLOF QUANTITY(BOQ) AS PER FORM-1D, THE TECHNICAL SPECIFICATIONMENTIONED IN BILL OF QUANTITY ( FORM 1 D) SHALL PREVAIL.ALSO REFERANNEXURE – AA FOR PRICE BASIS OF ELECTRICAL WORKS.

Page 41: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 41

ANNEXURE-AA

POINT WIRING

The rates for all point wiring items shall include :1. Conduits, Conduit specials, bushes and other fittings concealed or exposed as called

for.2. Embedding conduit and allied fittings including the outlet boxes in walls, floors etc.,

during construction and/or in chases including cutting chases and making good withcement mortar as necessary in the case of concealed conduit work.

3. Providing and fixing approved fixing devices, saddles and grouting the same asrequired for exposed conduits.

4. Fabrication and Supply of G.I .boxes for switches, ceiling fan hooks, Exhaust fansoutlet and lighting fixtures with 1.6 mm thick sheet steel.

5. Providing and fixing junction boxes with 3mm Hylam or 3mm/5mm thick Perspexsheet cover duly painted from inside to match the colour of the walls. All Junctionboxes shall be MS only.

6. All fixing accessories such as clips, brass screws/brass washers rawl plugs etc.7. All work & material necessary (including circuit wiring from DB to first tapping point

of each circuit with 2.5 sq. mm wires) in complete wiring of a switch circuit of anylength from the distribution board to the following via the switch:a) Ceiling rose b) Connector c) Back plate d) Socket outlet e) Lamps Holderf) Any other terminal outlet boxes g) Ceiling fan and Exhaust fan

8. Switch, socket outlet as called for.9. Cable/wire as required upto lamp holder.10. All metal boxes and boards concealed or surface mounted including those required

for housing fan regulators.11. All accessories necessary to complete wiring as specified.12. FRLS PVC Insulated stranded Copper conductor earth wire for fixtures, switch outlet

boxes and third pin of 5/15 Amps. socket to common earth.13. Painting all exposed M.S. conduits, outlet boxes and junction boxes.14. M.S. conduit for concealed and exposed wiring.15. 2 mm dia G.I. pull wires in conduit work, wherever necessary.16. The switch plate shall be made of I.S.I. grade Urea Formaldehyde Moulding powder.

The base of the switches shall be made from high heat resistant phenolformaldehyde powder. The cost of switches shall include the cost of cover plates,cadmium fixing screws etc.The switches/sockets shall be rocker operated.

17. Separate Earth wire shall run along with each circuit both for power and light circuits.18. Cutting of floor and making good for carrying conduits also.19. Numbering of Circuits with ferrules for all circuits at both ends.20. Providing 15 Amps capacity Bakelite terminal Blocks for terminating the phase,

neutral and earth wire at each fixture location.21. PVC insulated copper conductor wire ends before connection shall be properly

soldered (at least 15 mm length) with special Cu solder for copper conductor or shallbe properly crimped with copper lugs/sockets as the case may be. Strands of wiresshall not be out for connecting to the terminals. All stands of wires shall be solderedat the end before connection. The connecting brass-screws shall have flat ends. Alllooped joints shall be soldered and connected through terminal block/connectors.

22. Provide embossing on the sockets engraving “UPS” and “RAW”

CONDUITING & WIRING FOR TELEPHONE & COMPUTER SYSTEM

The rates for conduit work shall include :

1. All necessary specials and fittings.

Page 42: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 42

2. M. S. inspection, junction and outlet boxes as required.3. 3/5 mm thick perspex sheet covers for inspection & junction boxes.4. All fixing accessories such as clips, nails, brass screws/brass washers, etc.5. 2 mm dia G.I. pull wires in conduit work, wherever necessary.6. Providing and fixing approved saddle, hooks and grouting the same as required in the

case of all exposed conduit work.7. Embedding conduit and allied fittings including the outlet boxes in walls, floors etc.,

during construction and/or in chases including cutting chases and making good withcement mortar as necessary in the case of concealed conduit work.

8. Painting all inspection, junction and outlet boxes.9. PVC conduit for concealed conduit wiring .10. Painting of Hylam/perspex sheet cover from inside to suit the colour of the surrounding

wall with two coats of paint.11. Supply and fabrication of G.I. outlet boxes .12. The outlet cover plate for Telephone outlets shall be made of I.S.I. grade Urea

Formaldehyde Moulding powder. The cost of outlets shall include the cost of coverplates, cadmium fixing screws etc. also.

13. Numbering of wires on both ends of the wires for easy identification with PVC ferrules.

EARTHING

The rates for earthing items include :

1. All fixing accessories such as brass saddles, brass screws, rawl plugs etc.2. Jointing by riveting in case of copper earth strips ( 2 per joint) and by welding in case

of GI strips.3. Cutting chase, making holes and making good the same wherever required.4. All masonry work including earth work for earthing stations, earthing tapes and wires.5. Effecting adequate and proper interconnections.6. Use of copper thimbles for all wire terminations in the Distribution Boards , switches

and sockets.

SUPPLY & FIXING OF LIGHTING FIXTURES AND FANS

The rate for fixing of lighting fixtures and fans shall include:1. Receiving the fixtures from the Owners’s stores and assemble the same at site and

testing the fixture before fixing.2. All components that may be required to make the installation complete in all respects

such as:

a. Suitable length of down rod, hanger and connecting wires, where called for.b. Wires for connecting the fixtures to the point through connector blocks.c. All wood and metal blocks to serve as base of fixtures.d. Bonding with common earth wires.

3. Drilling holes in supports where required.4. Fixing clamps, GI bolts and nuts, clips, brass screws, dash fasteners and other fixing

accessories as required, including leaving necessary provision for fixing at time ofconcreting.

5. Approved enamel painting for hanger rods, clamps and other components and fixingaccessories as called for.

6. Testing and commissioning of all fixtures and fans after installation.7. The lighting fixtures shall be suitable for 230 Volts, single phase 50 cycles A.C. supply

system.8. Incandescent lamps shall be 100 Watts (maximum) and fluorescent lamps shall be 18

watts and 36 watts.

Page 43: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 43

9. Use G.I. suspenders and clamping to the slab with dash fasteners( 4 per fitting) ,including turn buckle arrangements for adjustable heights for hanging. They shouldbe the same suspenders as used for hanging the False Ceiling grid ceiling.

10. The contractor to mark the size of light fittings, speaker and fire alarm componentson the false ceiling for the interior contractor to cut holes.

Page 44: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 44

TECHNICAL SPECIFICATION FOR FURNITUTRE

Page 45: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 45

1.0 SPECIFICATIONS FOR FURNITURE /INTERIOR WORKS

MODULAR CURVILINEAR WORKSTATION with dimension 1500 x 1500 x 1200having 75mm thick tile based partition and following specifications. Completefurniture partition should be in extruded aluminum and not in CRCA steel.

1.1 FRAME WORK

1.1.1 Extruded aluminum vertical and horizontal members, 75mm wide that can belinked vertically & horizontally to any desired configuration. Frames shall be in 6widths-450mm, 600mm, 750mm, 900 mm, 1050mm and 1200mm.

1.2 JOINERY

1.2.1 All connections shall be made with M6 screws.

1.2.2 TOPRUNNERS AND BOTTOM SKIRTING

1.2.3 The bottom skirting shall be 95 mm high. These plates are aluminum plates withpowder coat finish and are supplied pre fitted with each frame.

1.3 END TRIMS

1.3.1 Exposed round vertical & horizontal ends shall be covered by an aluminumpowder coated finish, which is fixed accurately at these ends.

1.4 Corner Posts

1.4.1 Module frames shall be joined by means of heavy aluminum connectors, whichaccept the standard M6 screws.

1.5 Height Adjusters

1.5.1 Modular partition frames shall be supplied with heavy-duty levelers in the bottomto adjust the unevenness of the floor. They shall be accessible without removingthe skirting. The leveling bolt allows up to 50-mm adjustment.

1.6 Stability1.71.7.1 Stability of Module partition does not depends on the worktop cantilevers to it.

The only requirement is a stable layout in T, L and U configurations. Thepartitions configurations are free standing and do not require any indentation tobe done in the floor.

1.7.2 The 75 mm thick extruded frame shall be sufficiently rigid such that worktopsand other accessories can be cantilevered at any desired point without affectingthe overall stability.

1.8 Powder Coating

1.8.1 Powder Coating of aluminum components shall be 40-50 microns in thickness.

1.9 FASCIA TILES

Page 46: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 46

1.9.1 Module Fascia Tiles is 9 mm thick particleboard / MDF panels fitted with nylonclips.

1.9.2 These tiles can be unlatched with a flat tool for the removal.

1.9.3 Module fascia tiles are normally available in a wide variety of surface finishes –FABRIC, LAMINATE & MARKER BOARD.

1.10 SOFTBOARD TILES

1.10.1 Made from 9-mm thick soft board with GI frame backing to give strength andcovered with fabric.

1.11 GLASS PANELS

1.11.1 4mm Double glazed glass can be fitted to any module frame & are completelyinterchangeable with regular tiles at any time.

1.12 WIRE MANAGEMENT

1.12.1 Inlet: Entry of wires shall be from corner posts or sides or frames. Wires fromceiling are taken through a down pole, which is fitted on top of the post.

1.12.2 Outlet: electrical delivery ducts shall be fitted on the frames – bellow or abovethe worktop. The similar duct can be provided at the skirting also.

1.13 TRANSMISSION

1.13.1 Within a partition: Partition are hollow and allow free horizontal and verticalmovement of wires from inlet, outlet or to the next partition.

1.14 WORKTOP

1.14.1 Curvilinear Worktops are 25mm thick pre-laminated particle board with suedefinish lamination. All edges should be treated with 2mm PVC edges banded.

1.15 GABLE ENDS

1.15.1 Worktop shall be supported at one end by side panels (Gable Ends) rather thancantilevers bracket if desired. Gable ends are 25 mm thick and attached to theModule frames.

1.16 KEY BOARD TRAY

1.16.1 All worktops can be supplied with a pull out keyboard tray made of METALmounted below the surface.

1.17 FREE STANDING STORAGE

1.17.1 Module pedestals are constructed from pre-laminated board consisting of 2utility drawer and 1 filing box drawer. The exterior is made of 18-mm prelaminated board, while the drawers are of 12 mm board. All telescopic slidesshould have soft close provision.

1.18 The product should have ISO 9001:2000, OHSAS 18001:2007 and ISO 14001-2004 certifications.

Page 47: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 47

2.0 WOODEN STORAGES free standing wooden storages with following featuresproduct SIZE 900 W X 450 D X 1200 H

2.1 CONSTRUCTION

2.1.1 Rigid knock down construction. Open-able shutters shall be made of 18 mmthick pre laminated particle board, verticals and bottom shall be made of 18mmthick pre laminated particle board and back also made of 18mm thick prelaminated particle board. The top shall be of 25mm thickness.

2.2 SHUTTERS

2.2.1 Open-able shutters having 2 adjustable shelves making 3 compartments.

2.2.2 With PVC edge bending on all the exposed edges. Having all necessary fittings ofhettich/ebco make soft close hinges, locks and any miscellaneous items.

3.0 STORAGES IN CONFERENCE ROOM free standing wooden storages withfollowing features Product Size 900 W X 450 D X 750 H

3.1 CONSTRUCTION

3.1.1 Rigid knock down construction. Open-able shutters shall be made of 18 mmthick pre laminated particle board, verticals and bottom shall be made of 18mmthick pre laminated particle board and back made of 18mm thick pre laminatedparticle board. The top shall be of 25mm thickness.

3.2 SHUTTERS

3.2.1 Having swing doors with glass shutters with 1 adjustable shelves making 2compartments.

3.2.2 With PVC edge bending on all the exposed edges. Having all necessary fittings ofhettich/ebco make soft close hinges, locks and any miscellaneous items.

4.0 METAL STORAGES SIZE W-910 X D-455 X H-1980. the allowable dimensionaltolerance for overall size of the storage will be (+ / - 5mm). Similarly in theangle bending (+ / - 3mm) in degree. free standing CRCA almirah

4.1 CONSTRUCTION

4.1.1 The Storage shelves shall be fabricated with integrated welded construction.Body shall be made of 0.8mm CRCA sheets. Complete structure should bePowder Coated. All the components should have finished 40 to 50 microns thickepoxy polyester powder coating oven baked at 180 to 200 deg. C. The coldrolled cold annealed (CRCA) sheets of 0.8mm thickness and strips and having sixfolds as per design.

4.2 SHELVES

4.2.1 Each standard storage having loading shelves and the shelves can be adjustableas per requirement with suitable systems such as clips, nuts and bolts.

4.2.2 Adjustable Shelves making 5 Compartments. Knock down Structure. The Storageangle is precision punches slotted strips bended at sides to support the shelves

Page 48: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 48

to ensure flexibility in adjusting the height of the shelves. Shelves are able tocarry maximum 40kgs. UDL (Uniformly Distributed Load).

4.3 FITTINGS

4.3.1 Having all necessary fittings like hettich/ebco make soft close hinges, multi pointlocks and any miscellaneous items.

5.0 CHAIR WITHOUT HEADRESTHIGH BACK CHAIR WITHOUT HEADREST, VENTILATING MESH BACK,ADJUSTABLE LUMBAR PAD & SYNCHRONIZED TILT MECHANISM.

5.1 ARMREST

5.1.1 2 way armrest adjust for 6 cm in height and swivel into 3 angular positions.

5.2 BACKREST

5.2.1 A breathable polyester mesh suspension allows improve ventilation andtranspiration to provide exceptional thermal comfort. Back frame is moulded ofresilient black poly polypropylene.

5.3 LUMBER SUPPORT PAD

5.3.1 Lumber support shall be conveniently adjusted by side knobs without getting upfrom chair to customize the exact support for various panel shapes.

5.4 CHAIR MECHANISM

5.4.1 Syncro- tilt chairs employs a synchronized mechanism with tilt tension controlmulti position tilt lock, and pneumatic seat height control. Advanced swivel tiltchair provide tilt tension control multi position tilt lock, and pneumatic seatheight control.

5.5 BASE

5.5.1 This standard base is aluminum with black powder coating. Hooded dual wheelcastors in black nylon

5.6 Tilt Tension Control to obtain a balanced relining resistance.

5.7 Multi-position tilt Lock allows the back to be engaged to the preferred reclineangle.

5.8 As per manufacturer's specifications, drawings & direction of Engineer in charge.The above chair should be as per specification and sample approved by client.

6.0 CHAIR WITH HEADRESTHIGH BACK CHAIR, HEADREST, VENTILATING MESH BACK, LUMBAR PAD &SYNCHRONIZED TILT MECHANISM.

6.1 HEADREST

Page 49: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 49

6.1.1 Headrest should be adjustable for 5 cm in height. Headrest constructed bystretching mesh fabric or leather over a springy poly polypropylene frame. Isadjustable for 5cm in height and for 40 degree of tilt.

6.2 ARMREST

6.2.1 Two way armrest adjust for 6 cm in height and swivel into 3 angular positions.

6.3 BACKREST

6.3.1 A breathable polyester mesh suspension allows improve ventilation andtranspiration to provide exceptional thermal comfort. Back frame is moulded ofresilent black poly polypropylene.

6.4 LUMBER SUPPORT PAD

6.4.1 Lumber support shall be conveniently adjusted by side knobs without getting upfrom chair to customize the exact support for various panel shapes.

6.5 CHAIR MECHANISM syncro- tilt chairs, synchronized mechanism, tilt tensioncontrol multi position tilt lock, pneumatic seat height control, advanced swivel tiltchair, tilt tension control multi position tilt lock & pneumatic seat height control.

6.6 BASE

6.6.1 This standard base is aluminum with black powder coated. Hooded dual wheelcastors in black nylon as per manufacturer's specifications, drawings & directionof Engineer in charge.

7.0 CHAIR WITH FIXED ARMLOW BACK CHAIR, PP FIXED ARM, BASE PP, TILT MECHANISM, NET BACK &FABRIC TAPESTRY.

7.1 SEAT/BACK

7.1.1 The seat shall be made up of heat pressed plywood, upholestry with fabric andmolded poly urethane foam, together with moulded seat of 50 density. The backis made of mesh type. Seat overall shall be 22'' wide and 18'' deep with waterfalldesign. Seat height adjustable shall be 16'' to 18''. Back shall be 18'' with makingtotal chair height of 35’’.

7.2 POLYURETHANE FOAM

7.2.1 The foam shall be moulded with density 50-55 and hardness=20.

7.3 SEAT COVERS

7.3.1 The seat cover shall be injection moulded in black co polymer polypropylene.

7.4 ARMREST FIXED TYPE

7.4.1 The one piece armrest are made of black integral skin polyurethane with 50-70hardness and reinforced with M.S. insert. The arm-rest are fitted onto the seatwith powder coated armrest brackets.

7.5 PNEUMATIC HEIGHT ADJUSTMENT

Page 50: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 50

7.5.1 Has an adjustment stroke of 5cm.

7.6 PEDESTAL ASSEMBLY

7.6.1 The pedestal is injection moulded in black 30% glass filled nylon and fitted with5 nos twin wheel castors.

7.7 TWIN WHEEL CASTORS

7.7.1 The twin wheel castors are injection moulded in 30% glass filled black nylon.

7.8 All are as per manufacturer's specifications, drawings & direction of Engineer incharge.

8.0 CHAIR WITH ADJUSTABLE ARM

8.1 Providing and supplying medium Back Chair with PP adjustable arm. Base ismade of PP, having push back mechanism, net back, Fabric Tapestry.

8.2 SEAT/BACK

8.2.1 The seat shall be made up of heat pressed plywood, upholestry with fabric andmolded poly urethane foam of 50 density, together with moulded seat covers.The back is made of mesh type. Seat overall shall be 22'' wide and 18'' deepwith waterfall design. Seat height adjustable shall be 16'' to 18''. Back shall be18'' with making total chair height of 35’’.

8.3 POLYURETHANE FOAM

8.3.1 The foam is moulded with density 50-55 and hardness=20.

8.4 SEAT COVERS

8.4.1 The seat cover shall be injection moulded in black co polymer polypropylene.

8.5 ARMREST ADJUSTABLE TYPE

8.5.1 The armrest are made of black integral skin polyurethane with 50-70 hardnessand reinforced with M.S. insert. The arm-rest are fitted onto the seat withpowder coated armrest brackets. Arms height should be adjust upto 6-7 cms.

8.6 PNEUMATIC HEIGHT ADJUSTMENT

8.6.1 Has an adjustment stroke of 10cm.

8.7 PEDESTAL ASSEMBLY

8.7.1 The pedestal is injection moulded in black 30% glass filled nylon and fitted with5 no twin wheel castors.

8.8 TWIN WHEEL CASTORS

8.8.1 The twin wheel castors are injection moulded in 30% glass filled black nylon.

Page 51: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 51

9.0 READING CHAIRPU ARM, MS POWDER COATED BASE & FABRIC TAPESTRY.

9.1 Providing and supplying low Back Chair with PP arm. Seat fixed on MS tubularframe.

9.2 SEAT/BACK

9.2.1 The seat and back shall be made up of heat pressed plywood, upholestry withfabric and molded poly urethane foam, together with moulded seat covers. Seatoverall shall be 20'' wide and 18'' deep with waterfall design. Back shall be 15''with making total chair height of 29’’.

9.3 POLYURETHANE FOAM

9.3.1 The foam is moulded with density 50-55 and hardness=20.

9.4 SEAT COVERS

9.4.1 The seat cover shall be injection moulded in black co polymer polypropylene.

9.5 ARMREST FIXED TYPE

9.5.1 The one piece armrest are made of black integral skin polyurethane with 50-70hardness and reinforced with M.S. insert. The arm-rest are fitted onto the seatwith powder coated armrest brackets.

9.6 BASE

9.6.1 The Base is made of welded structure made of MS tubular frame.

9.6.2 All are as per manufacturer's specifications, drawings & direction of Engineer incharge.

10.0 CHAIR FOR CAFETARIA

10.1 Providing and supplying cafeteria Chair with Plastic seat and back. Base shall bemade of pipe stand, as per manufacturer's specifications, drawings & direction ofEngineer in charge.

11.0 3 SEATER SOFA IN OFFICE ROOM

11.1 Sofa with Chrome Plated frame having cushion Tapestry. The base structureshall be made of Pipe Stand in Chrome Finish. The above furniture should be asper specification and sample approved by client.

12.0 CHAIR WITH CHROME BASE

12.1 Providing and supplying medium Back Chair with MS chrome arm. Base shall bemade of MS chrome, having centre tilt mechanism, PU upholstery.

12.2 SEAT/BACK

12.2.1 Seat overall shall be 22'' wide and 18'' deep. Seat height adjustable shall be 16''to 18''. Back shall be 22'' with making total chair height of 39’’.

Page 52: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 52

12.3 ARMREST FIXED TYPE

12.3.1 The armrest shall be made of black integral skin polyurethane with 50-70hardness and reinforced with M.S. insert. The arm-rest should be fitted onto theseat with powder coated armrest brackets.

12.4 PNEUMATIC HEIGHT ADJUSTMENT

12.4.1 Has an adjustment stroke of 5cm.

12.5 PEDESTAL ASSEMBLY

12.5.1 The pedestal should be injection molded in chrome base and fitted with 5 notwin wheel nylon castors.

12.6 TWIN WHEEL CASTORS

12.7 The twin wheel castors should be injection molded in 30% glass filled blacknylon.

12.8 All are as per manufacturer's specifications, drawings & direction of Engineer incharge.

13.0 CHAIR MESH TYPE WITH FIXED BASE medium Back Chair with PPadjustable arm. Base shall be made of MS tubular frame, having push backmechanism, net back, Fabric Tapestry.

13.1 SEAT/BACK

13.1.1 The seat shall be made up of heat pressed plywood, upholstery with fabric andmolded poly urethane foam, together with moulded seat covers. The backshould be made of mesh type. Seat overall shall be 22'' wide and 18'' deep withwaterfall design. Seat height adjustable shall be 16'' to 18''. Back shall be 18''with making total chair height of 35’’.

13.2 POLYURETHANE FOAM

13.2.1 The foam should be molded with density 50-55 and hardness=20.

13.3 SEAT COVERS

13.3.1 The seat cover shall be injection moulded in black co polymer polypropylene.

13.4 ARMREST ADJUSTABLE TYPE

13.4.1 The armrest shall be made of black integral skin polyurethane with 50-70hardness and reinforced with M.S. insert. The arm-rest should be fitted onto theseat with powder coated armrest brackets. Arms height should be adjust upto 6-7 cms.

13.5 PEDESTAL ASSEMBLY

13.5.1 The fixed type pedestal should be made of chrome finish tubular frame.

Page 53: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 53

13.5.2 All are as per manufacturer's specifications, drawings & direction of Engineer incharge. The above furniture should be as per specification and sample approvedby client.

14.0 CHAIRS

14.1 Providing and supplying low Back Chair with chrome finish arm. Base should bemade of tubular pipe chrome plated, having plastic back

14.2 Wooden writing table of size 300 X 250 and Tapestry as per manufacturer'sspecifications, drawings & direction of Engineer in charge.

15.0 STOOL FOR PATIENT DIMENSIONS: 12 X 12 X 20

15.1 Visitor Stools shall have ERW frame that makes it extremely durable. Moreover,the legs of the stools are fitted with rubber feet. . To achieve long lastingperformance, these stools shall be pretreated and powder coated with 40-50microns thick epoxy polyester powder coating oven baked at 180-200 degreecentralized temperature. The above furniture should be as per specification andsample approved by client.

15.2 CRC or steel sheet duly double press bent

15.3 Pre-treated and epoxy powder coated

15.4 M.S. tubular frame fitted with PVC stump

16.0 SOFA

16.1 SOFA NORMAL IN FULLY LEATHER 3 SEATER Dimension L 2005 X D 760 X H860

16.1.1 Base made of ply, moulded cushion 4'' high maple solids with double dowelconstruction, corner blocked legs and rails.

16.1.2 Seat multi-density polyurethane foam, Catalyzed lacquer finish in all Cumberlandmapple finishes

16.1.3 Seat spring 6cm wide reinforced elastic straps fixed 4.5cm apart forming a thickand extremely resistant base.

16.2 SOFA IN FULL LEATHERITE 1 SEATER, 2 SEATER AND 3 SEATER MODEL

16.2.1 Base ply with moulded cushion 4'' high

16.2.2 LEFT & RIGHT SIDE FRAME

16.2.2.1 Frames M.S. ERW tubes and chrome plated fitted at the extreme ends to formleg assembly

16.2.3 MOUNTING FRAMES

16.2.3.1 Mounting frames made of M.S. ERW tubes assy. to hold the two side frametogether.

Page 54: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 54

16.2.4 ASSEMBLY

16.2.4.1 The complete frame shall be covered with replaceable leatherite. All externalsurfaces have chrome finish.

16.3 SOFA FULL LEATHER IN 1 SEATER, 2 SEATER AND 3 SEATER MODEL

16.3.1 Base ply with moulded cushion 4'' high

16.3.2 LEFT & RIGHT SIDE FRAME

16.3.2.1 Frames M.S. ERW tubes and chrome plated fitted at the extreme ends to formleg assembly.

16.3.3 MOUNTING FRAMES

16.3.3.1 Mounting frames made of M.S. ERW tubes assy. to hold the two side frametogether. Mounting frames assy. holds the two side frame together.

16.3.4 ASSEMBLY

16.3.4.1 The complete frame chrome finish covered with replaceable leather.

17.0 MANAGER TABLE LAMINATED SIZE 2000mm W X 800mm D X 750mm H

17.1 MANAGER TABLE PRE-LAMINATED BOARD WITH SIDE STORAGE

17.1.1 CREDENZA (SIDE UNIT) SIZE

17.1.1.1 1200mm x 450mm x 750mm

17.1.2 FULL HEIGHT BACK UNIT SIZE

17.1.2.1 1200mm x 450mm x 1800mm

17.1.3 PEDESTAL UNIT SIZE

17.1.3.1 400mm x 450mm x 670mm (Mobile type)

17.1.4 TABLE -TOP

17.1.4.1 25 to 40mm thick should be made of pre-laminated particle board

17.1.5 SHUTTERS

17.1.5.1 Should be made of 18mm thick pre-laminated particle board

17.1.5.2 The details of each unit are given as under

17.1.6 TABLE TOP D2000mm W X 800mm D X 750mm H

17.1.6.1 The table top consisting the top should be made out of 25-40mm thick pre-laminated particle board. The edges of the top shall be covered with edgebending tapes as per selection and approved design. The top shall be joinedwith guide pin and dowels. Two number of strengthening support (vertical)having rectangular shape and made out of 18mm thick pre-laminated particle

Page 55: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 55

board of approved colour/design and PVC edge banding on over all visibleedges will be provided.

17.1.7 SIDE SUPPORT WITH WOODEN LEGS

17.1.7.1 Two decorative wooden pillar legs (of any colour) with two supporting side &one front supporting leg made out of 18mm thick pre-laminated particle board ofapproved colour /design and decorative wooden beading at floor level (i.e. threesides) . Having all necessary fittings of hettich/ebco make soft close hinges,locks and any miscellaneous items.

17.1.8 SIDE CREDENZA UNIT DIMENSION 1200mm x 450mm x 750mm

17.1.8.1 The top of this unit should be made out of 25-40mm thick pre-laminated particleboard on the upper side. The edges of top shall be covered with edge bendingtapes as per selection and approved design and line with main table. Top rest ontwo side supporting legs of size 450mm x 725 made out of 18mm thick pre-laminated particle board. Flat edges duly sealed with PVC edges beadingmodesty panel of size 1150 X 600 made out of 18mm particle board laminated.Having all necessary fittings of hettich/ebco make soft close hinges, locks andany miscellaneous items.

17.1.9 PEDESTAL UNIT DIMENSION 400MM X 450MM X 670MM

17.1.9.1 This unit shall be made out of 18mm thick pre-laminated board with havingthree sliding drawer mounted on steel soft close telescopic channels havingcentralized locking. Having all necessary fittings of hettich/ebco make soft closehinges, locks and any miscellaneous items.

17.1.10 FULL HEIGHT BACK UNIT DIMENSION 1200mm x 450mm x 1800mm

17.1.10.1 The whole back unit should be made out of 18mm thick pre laminated particleboard of approved colour / design. The complete unit jointed with guide pins &donels. Having all necessary fittings of hettich/ebco make soft close hinges,locks and any miscellaneous items.

17.1.11 HANDLES17.1.11.1 Handle shall be aesthetically designed handles in SS finish. All the exposed

edges are sealed with machine pressed 2mm thick PVC edge band. It shall haverigid knock down construction.

17.1.12 The product should have ISO 9001:2000, OHSAS 18001:2007 and ISO 14001-2004 certifications.

18.0 MANAGER TABLE PRE-LAMINATED BOARD WITH SIDE STORAGEMETAL MODESTY

18.1 providing and supplying main table of dimension

18.2 MAIN TABLE TOP SIZE

18.2.1 1500mm W X 750mm D X 750mm H

18.3 CREDENZA (SIDE UNIT) SIZE

Page 56: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 56

18.3.1 1200mm x 450mm x 750mm

18.4 PEDESTAL UNIT SIZE

18.4.1 400mm x 450mm x 670mm (Mobile type)

18.5 TABLE –TOP

18.5.1 25 mm thick made of pre-laminated particle board

18.6 SHUTTERS

18.6.1 Shall be made of 18mm thick pre-laminated particle board

18.7 THE DETAILS OF EACH UNIT ARE GIVEN AS UNDER

18.7.1 Table Top

18.7.1.1 The table top size 1500mm W X 750mm D X 750mm H consisting the top shouldbe made out of 25mm thick pre-laminated particle board . The edges of the topshall be covered with edge bending tapes as per selection and approved design.The top shall be joined with guide pin and dowels. Top will be supported onmetal legs and should have metal modesty.

18.8 SIDE CREDENZA UNIT DIMENSION 1200mm x 450mm x 750mm

18.9 The top of this unit should be made out of 25mm thick pre-laminated particleboard on the upper side. The edges of the top shall be covered with edgebending tapes as per selection and approved design and line with main table.Top rest on two side supporting legs. The whole back unit would be made out of18mm thick pre laminated particle board of approved colour / design. Thecomplete unit jointed with guide pins & donels.

18.10 Pedestal Unit DIMENSION 400mm X 450mm X 670mm

18.10.1.1 This unit should be made out of 18mm thick pre-laminated board with havingthree sliding drawer mounted on steel telescopic channels having centralizedlocking. Having all necessary fittings of hettich/ebco make soft close hinges,locks and any miscellaneous items.

18.11 HANDLES

18.11.1 Handle shall be aesthetically designed handles in SS finish. All the exposededges are sealed with machine pressed 2mm thick PVC edge band. It shall haverigid knock down construction.

18.12 The product should have ISO 9001:2000, OHSAS 18001:2007 and ISO 14001-2004 certifications.

19.0 MAIN TABLE

19.1 MAIN TABLE TOP SIZE

19.1.1 2100mm W X 900mm D X 750mm H

Page 57: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 57

19.1.2 CREDENZA (SIDE UNIT) SIZE

19.1.3 1200mm x 450mm x 750mm

19.2 FULL HEIGHT BACK UNIT SIZE

19.2.1 2400mm x 450mm x 1800mm

19.3 PEDESTAL UNIT SIZE

19.3.1 400mm x 450mm x 670mm (Mobile type)

19.4 TABLE -TOP

19.4.1 25 to 40mm thick should be made of MDF board having veneer finish

19.5 SHUTTERS

19.5.1 Should be made of MDF board with veneer finish

19.6 The details of each unit are given as under

19.6.1 TABLE TOP

19.6.1.1 The table top size 2100mm W X 900mm D X 750mm H consisting the top shouldbe made out of 25-40mm thick MDF board having veneer finish . The edge ofthe top should have reverse bull nose edge. The edges of the top shall beproperly finished as per selection and approved design. The top will be joinedwith guide pin and dowels. Two number of strengthening support (vertical)having rectangular shape and made out of 18mm thick MDF board with veneerfinish of approved colour/design shall be provided.

20.0 CHAIRMAN TABLE IN VENEER FINISH

20.1 SIDE SUPPORT WITH WOODEN LEGS

20.1.1 Two decorative wooden pillar legs (of any colour) with two supporting side &one front supporting leg made out of 18mm thick MDF board with veneer finishof approved colour /design and decorative wooden beading at floor level (i.e.three sides).

20.2 SIDE CREDENZA UNIT

20.2.1 1200mm x 450mm x 750mm20.2.1.1 The top of this unit should be made out of 25-40mm thick MDF board with

veneer finish. The edge of the top should have reverse bull nose edge matchingwith the main table top. The edges of top shall be properly finished as perapproved design and line with main table. Top rest on two side supporting legsof size 450mm x 725 made out of 18mm thick MDF board with veneer finish.Having all necessary fittings of hettich/ebco make soft close hinges, locks andany miscellaneous items.

20.3 PEDESTAL UNIT

20.3.1 400mm X 450mm X 670mm

Page 58: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 58

20.3.1.1 This unit shall be made out of 18mm thick MDF board with veneer finish havingthree sliding drawer mounted on steel telescopic channels having centralizedlocking. Having all necessary fittings of hettich/ebco make soft close hinges,locks and any miscellaneous items.

20.4 FULL HEIGHT BACK UNIT SIZE DIMENSION 2400MM X 450MM X 1800MM

20.4.1.1 The whole back unit would be made out of 18mm thick MDF board with veneerfinish of approved colour / design. The complete unit jointed with guide pins &donels. Having all necessary fittings of hettich/ebco make soft close hinges,locks and any miscellaneous items.

20.5 HANDLES

20.5.1 Handle shall be aesthetically designed handles in SS finish. All the exposededges are sealed with machine pressed 2mm thick PVC edge band. It shall haverigid knock down construction.

20.6 The product should have ISO 9001:2000, OHSAS 18001:2007 and ISO 14001-2004 certifications. The above furniture should be as per specification andsample approved by client.

21.0 CENTER TABLE AND CORNER TABLES IN MANAGER'S CABIN DIMENSION1100 MM L X 750MM D X 450MM H.

21.1 Table in shape of rectangle/oval/mushroom type/square.

21.2 Made with teak wood having open grain wenge stain and white lacquered glasson the top.

22.0 CENTRE TABLE AND CORNER TABLE DIMENSION 550 MM L X 550MM D X450MM H.

22.1 Table in shape of rectangle/oval/mushroom type/square.

22.2 Table with top made of 10mm thick toughened glass fixed using the studs. Withbase legs made of metal of 16 gauge. The above furniture should be as perspecification and sample approved by client.

23.0 DISCUSSION TABLE

23.1 DISCUSSION TABLE/ CONFERENCE TABLE VENEER FINISH DIMENSION 7200MMW X 1800MM D X 750MM H.

23.1.1 Work surface (Oval shape) shall be made of 40MM thk MDF Board Top havingveneer finish with all the exposed edges been proper finish. The glass shall befixed in between for designer look.

23.1.2 The legs shall be made of 25mm MDF board with veneer finish and havingstraight profile.

23.1.3 Modesty panel shall be made of 25mm MDF board with veneer finish and havingstraight profile.

Page 59: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 59

23.1.4 Along with 2 No’s motorized wire manager with brush flap of dimension(W374mm*D110mm*H103mm) for provision of three power, one data, oneVGA, one audio, one microphone.

23.2 DISCUSSION TABLE /CONFERENCE TABLE LAMINATE FINISH DIMENSION2700MM W X 900MM D X 750MM H

23.2.1 Work surface shall be made of 25MM thk pre-laminated particle Board Top withall the exposed edges been proper finish with PVC edge bending.

23.2.2 The legs shall be made of 25mm thick pre-laminated particle board havingstraight profile.

23.2.3 Modesty panel shall be made of 25mm thick pre-laminated particle board havingstraight profile.

23.2.4 Along with 1 No motorized wire manager with brush flap of dimension(W374mm*D110mm*H103mm) for provision of three power, one data, oneVGA, one audio, one microphone.

23.3 DISCUSISON TABLE ROUND TOP DISCUSSION TABLE DIMENSION DIA 900MMW X 750MM H

23.3.1 Work surface shall be made of 25MM thk pre-laminated particle Board Top withall the exposed edges been proper finish with PVC edge bending.

23.3.2 The legs shall be made of unique die casted legs with chrome finish

23.3.3 Having all necessary fittings of hettich/ebco make hindges . All the worktopsshould have metal inserts on the underside of worktops for coupling with metalscrews for complete modularity

24.0 LAB WORKING PLATFORM

24.1 Providing and supplying lab tables shall fulfill following specifications ,

24.2 Table top should made of (18 to 20mm) thick JET BLACK GRANITE TOP.Supported by ply of 6mm.

24.3 Table frame should of E.R.W.M.S. square Tubes 25x25mm thick and finishedwith epoxy powder coating.

24.4 Under bench should have storage modules made of 21 G C.R.C.A. Sheets.

24.5 The shutters are mounted to the modules by hinges which are open-able to 95degree & self-closing on return.

24.6 Telescopic channels shall be used for the slick telescopic drawer slides which arevery sturdy & can take load upto 30kg. Modules completely finished with epoxypowder coating. With minimum coating layer 40-50 micron.

25.0 LOCKERS LAB

Page 60: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 60

25.1 LOCKERS DIMENSION W-380XD-458XH-1800.

25.2 The personal locker with in-built locks and without in-built locks i.e, pad locktype having configuration depending on site conditions and the body size are380 wide, 458 deep ,1800 high for 6 lockable doors, The allowable dimensionaltolerance for overall size of the Locker is (+ / - 5mm). Similarly in the anglebending (+ / - 3) in degree. All the components are finished 40 to 50 micronsthick epoxy polyester powder coating oven baked at 180 to 200 deg. C. Bodyshall be made of 0.8mm CRCA sheets and complete structure is Powder Coated.The shutters of lockers shall be fixed with hinges having removable pins.

25.3 LOCKING ARRANGEMENT - Shall have 4 dial combination lock with ABS housinghaving green & Red indicator. With override Emergency master key & decodefunction. It should have provision of resetting combination after unlock.

25.4 Door Locker with each locker of dimension 380 W X 458mm D. Shall haveprovision for Index card holder and Ventilation holes.

26.0 BENCHES IN LOCKER ROOM

26.1 Providing and supplying benches in locker room of length 1200mm, height400mm and 300mm depth and Frames shall be constructed from strong38x38mm RHS steel which have a tough powder coat finish. Benches aresupplied with a choice of solid Ash or Sapele hardwood timber slats which arefinished with a tough satin lacquer.

27.0 DISPLAY RACK

27.1 Providing and fixing of DISPLAY RACKS DIMENSION 6000MM W X 450MM D X2100MM H

27.2 CONSTRUCTION

27.2.1 Rigid knock down construction.

27.3 MATERIAL

27.3.1 Structure shall be made with combination of powder coated aluminium andCRCA of approx 50-60 micron. Front shall have the Glass shutters. All necessaryfittings of hettich/ebco make hinges.

27.4 STACKABILITY

27.4.1 The add on units can be stacked width wise to form a bank of racks havingcommon side panel.

27.5 ACCESSIBILITY from front sides.

27.6 NUMBER OF RACKS

27.6.1 Bottom plus 4 fixed racks on each side

28.0 TABLE FOR PLANT SCALE MODEL DIMENSION 2000MM W X 2000MM DX 750MM

Page 61: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 61

28.1 Table top made of 12mm thick toughened glass. Supported on designer basemade of powder coated legs.

28.2 WORKSURFACE

28.2.1 With table top made of 10-12mm thick toughened glass. The height of Table topis 750mm.

28.3 LEGS

28.3.1 Top Supported on M.S. powder coated legs and structure size is 40 X 40.

28.4 Powder coating of approx 50-60 micron is done. Structure shall be completeknock down.

28.5 The product should have ISO 9001:2000 and ISO 14001-2004 certifications.

29.0 READER'S TABLE DIMENSION 1800MM W X 900MM D X 750MM H.

29.1 WORKSURFACE

29.1.1 With table top shall be made of 25mm thick pre-laminated particle board. All theexposed edges are sealed with machine pressed 2mm thick PVC edge band. Theheight of Table top is 750mm.

29.2 LEGS

29.2.1 Top Supported on powder coated legs and structure .powder coating of approx50-60 micron is done.

29.3 The product should have ISO 9001:2000, OHSAS 18001:2007 and ISO 14001-2004 certifications.

30.0 WOODEN LIBRARY RACKS

30.1 Providing and fixing of wooden library racks

30.2 PRODUCT SIZE DIMENSION 900MM W X 450MM D X 1800MM H

30.3 CONSTRUCTION

30.3.1 Rigid knock down construction.

30.4 MATERIAL

30.4.1 BACK PANEL shall be made of 18mm thick pre laminated particle board.SKIRTING & SIDE PANELS shall be made of 18 mm thick pre laminated particleboard.

30.5 With PVC edge bending on all the exposed edges. Having all necessary fittingslike hettich/ebco make hinges.

30.6 STACKABILITY

30.6.1 The add on units can be stacked width wise to form a bank of racks havingcommon side panel.

Page 62: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 62

30.7 ACCESSIBILITY from front and back as the racks are available on both the sides.

30.8 NUMBER OF RACKS

30.8.1 Bottom plus 4 fixed racks on each side

30.9 Label holder in each main unit to apply label for indication.

31.0 TABLES DIMENSION 1200X600 (MAIN TABLE). With pedestal,keyboard trey & CPU Trolley

31.1.1 providing and supplying main table of dimension 1200 X 600 X 750

31.1.2 WORKSURFACE

31.1.2.1 With table top shall be made of 25mm thick pre-laminated particle board. All theexposed edges are sealed with machine pressed 2mm thick PVC edge band. Theheight of Table top is 750mm.

31.1.3 WIRING

31.1.3.1 The metal raceway has been provided to fix the data and power cable sockets intable.

31.1.4 LEGS

31.1.4.1 Top Supported on 2 powder coated module legs. Legs shall be made of legframe, fascia & caps and tubes. Leg frame shall be made up of mild steel. Legfascia shall be made of CRCA and all are powder coating of approx. 50-60micron.

31.1.5 MODESTY

31.1.5.1 Modesty panel shall be made of 18mm thick pre-laminated particle board.

31.1.6 PEDESTAL

31.1.6.1 Module pedestals shall be constructed from pre-laminated particle boardconsisting of 2 utility drawer and 1 filing box drawer.

The product should have ISO 9001:2000, OHSAS 18001:2007 and ISO 14001-2004certifications.

31.2 STUDY TABLE IN HOSTEL DIMENSION 750MM WX450MM DX750MM H.

31.2.1 WORKSURFACE

31.2.1.1 The top shall be made of 25mm thick pre-laminated particle board with all thevisible edges covered with PVC edge bending.

31.2.2 LEGS

31.2.2.1 Made of 18mm thick pre-laminated particle board. With all the exposed edgesshall be covered with 2mm thick edge bending.

31.2.3 MODESTY PANEL

Page 63: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 63

31.2.3.1 Made of 18mm thick pre-laminated particle board. With all the exposed edgesshall be covered with 2mm thick edge bending.

31.2.3.2 Shall be provided with combination of storages and overhead storages havingclosed shutters fixed with hinges. The table shall have one drawer having lockingarrangement.

32.0 SINGLE BED IN HOSTEL QUEEN SIZE BED BASICALLY DIMENSION1981mm X 1524mm X 360mm

32.1 STRUCTURE

32.1.1 M.S. welded frame. And having pre-laminated gladding.

32.2 The bed base shall be made of 16 gauge mild steel. The structure shall begalvanized and powder coated.

32.3 The top should be made of 12mm thick blackboard or PLPB finished with polishto resist with moisture.

33.0 DOUBLE BED IN HOSTEL DIMENSION 1500MM X 1800MM X 360MM

33.1 Queen size bed made of wood bed without storage.

33.2 STRUCTURE

33.3 M.S. welded frame. And having pre-laminated gladding.

33.4 HEADBOARD

33.5 It shall have head board made of pre-laminated particle board.33.6 The bed base shall be made of 16 gauge mild steel. The structure shall be

galvanized and powder coated.33.7 The top should be made of plywood finished with polish to resist with moisture.

34.0 BED FOR PATIENT OVERALL DIMENSION: 203 (L) X 90 (W) X 60 (H)CM

34.1 Hospital Bed that is manufactured using high grade mild steel. These bedsshould have precise steel tubular frame work.

34.2 Frame work made of rectangular/ square M.S. tube

34.3 Top made of welded wire mesh

34.4 Tubular head & foot bows of unequal height

34.5 Location for Four I. V Rod

34.6 Finish: Epoxy powder coated.

35.0 SEMINAR HALL AREA

Page 64: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 64

35.1 AUDITORIUM CHAIR FLOOR GROUTED

35.1.1 Seat shall have Self Tip – Up Cushion. The Centre distance ( Arm – rest to Armrest ) 22” as required for different sizes mentioned for different locations, SheetMetal Components Side Stand 70mm X 30mm heavy gage pipe. 7mm HR Plateiron sheet deep drawn footrest.

35.1.2 Tip-up System shall have seat supporting tray of dimension 40 X 3 mm and BackClamps is of 14G HR sheet x 2 Nos.

35.1.3 Seat& Back Frame shall be made of 15mm thick Ply wood and Back frame ismade of Iron Frame MS Flat Patti.

35.1.4 Polyurethane Foams I Seat & Back cushioned with molded non-saggingpolyurethane molded foam of 50 density. Density is about : 50 +/- 5 Kg / M3as Per JIS K 6401

35.1.5 Hardness of cushion is about 120 (+30 / - 20) Newton and of Back rest is 80(+30 / - 10) Newton.

35.1.6 Constant Compression Set: (Max – 13%) JIS K 6401.

35.1.7 Fabric shall exactly be as per the sample approved by and the Color / Shade.

35.1.8 Spring For Auto-Tip-Torsion

35.1.9 Arm rest Wooden arm rest with PPCP Writing Pad

35.1.10 Back Cover PPCP

35.1.11 Seat Cover PPCP

36.0 RECEPTION TABLE

36.1 RECEPTION TABLE DIMENSION 2000 X 750 X 750 (worktop height) with followingelements.

36.2 WORKSURFACE

36.2.1 Table top shall be made of 36mm thick Acrylic solid surface (corian top only ofDU-POINT). Supported on designer base either made of corian or of veneerfinish.

36.2.2 GLASS

36.2.2.1 Frosted glass of 10mm thick is fixed with studs for designer's look.

36.2.2.2 It includes fixed type 3 drawer pedestal of veneer finish.

36.2.2.3 The product should have ISO 9001:2000, OHSAS 18001:2007 and ISO 14001-2004 certifications.

37.0 MODEL AND CHART TABLE DIMENSION 2400 X 1200 X 750

Page 65: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 65

37.1 Table top made of 12mm thick toughened glass. Supported on designer baseeither made of chrome finish or of veneer finish.

37.2 Providing and fixing of reading table of dimension 12400 X 1200 X 750

37.3 WORKSURFACE

37.3.1 With table top made of 10-12mm thick toughened glass. The height of Table topis 750mm.

37.4 LEGS

37.4.1 Top Supported on powder coated 40 X 40 metal legs and structure .powdercoating of approx 50-60 micron is done.

37.4.2 The product should have ISO 9001:2000, OHSAS 18001:2007 and ISO 14001-2004 certifications.

38.0 CAFETARIA TABLE DIMENSION 900MM X 750MM H. X 600 D.

38.1 WORKSURFACE

38.1.1 The top shall be made of 25mm thick pre-laminated particle board with all thevisible edges covered with PVC edge bending.

38.2 LEGS

38.2.1 Made of chrome finish. Having all necessary fittings like hettich/ebco makehinges.

39.0 METAL RACK

39.1.1 Providing and supplying metal racks of dimension W-900xD-450xH-2100.

39.1.2 Free standing CRCA rack with following features

39.2 PRODUCT SIZE DIMENSION W-900xD-450xH-2100.

39.2.1 CONSTRUCTION

39.2.1.1 Body is made of 0.8mm CRCA sheets. Complete structure is Powder Coated. Allthe components are finished 40 to 50 microns thick epoxy polyester powdercoating oven baked at 180 to 200 deg. C. The Rack angle is precision punchesslotted strips bended at sides to support the shelves to ensure flexibility inadjusting the height of the shelves.

39.2.2 LOAD CAPACITY

39.2.2.1 Shelves shall be able to carry maximum 40kgs. UDL (Uniformly Distributed Load.

39.2.2.2 The Rack shelves are fabricated with integrated welded construction.

39.2.2.3 Adjustable Shelves making 5 Compartments. Knock down Structure.

Page 66: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 66

39.2.2.4 Having all necessary fittings like hettich/ebco make hindges, locks and anymiscellaneous items.

40.0 LECTURE ROOM TABLE OF DIMENSION 1200X600 X 750 (Main Table).including pedestal, keyboard trey & CPU Trolley

40.1 WORKSURFACE

40.1.1 With table top shall be made of 25mm thick MDF board with veneer finish. Allthe exposed edges are sealed with proper finish. The height of Table top is750mm.

40.2 WIRING

40.2.1 The metal raceway has been provided to fix the data and power cable sockets intable. Along with 1 No motorized wire manager with brush flap ofdimension(W374mm*D110mm*H103mm) for provision of three power, onedata, one VGA, one audio, one microphone.

40.3 LEGS

40.3.1 Top Supported on 2 powder coated module legs. Legs shall be made of legframe, facia & caps and tubes. Leg frame shall be made up of mild steel. Legfascia shall be made of CRCA and all are powder coating of approx. 50-60micron.

40.4 MODESTY

40.4.1 Modesty panel made of CRCA sheet. Metal modesty shall be made of 0.8mmthick CRCA sheet and shall have square holes of 7mmx7mm in 50mm pitch alongvertically and horizontally.

SCOPE OF WORK IS DETAILED IN BILL OF QUANTITY (BOQ) & TENDER DRAWINGS (REFERFORM 1-D OF SCHEDULE OF PRICES). IN CASE OF ANY CONFLICT WITH THE GENERALSPECIFICATION SPECIFIED ABOVE AND THE BILL OF QUANTITY(BOQ) AS PER FORM-1D,THE TECHNICAL SPECIFICATION MENTIONED IN BILL OF QUANTITY ( FORM 1 D) SHALLPREVAIL.

Page 67: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 67

GENERAL SPECIFICATION FOR CEILING & PARTITION

Page 68: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 68

1.0 GENERAL SPECIFICATIONS FOR CEILING & PARTITION

1.1 General Requirements.

1.1.1 The section of the specification shall be read in conjunction with the Drawings, otherContract Documents and other sections of these specifications which shall be deemedto be complementary to one another. The Contractor carrying our this work shall beresponsible for providing all plant, tools, materials and all things necessary for theproper execution, completion and maintenance of these works.

1.2 Dimensions

1.2.1 Figured dimensions shall be taken in preference to scaled dimensions in all cases.Before commencing any work the Contractor shall verify all requirements on the Site.

1.3 Samples

1.3.1 A Sample of every item of furniture / paneling / cladding / flooring / all othercomponents, including their parts shall be submitted for approval before an order isplaced or manufacture commences. Approved samples shall be used as standards offinish and workmanship.

1.4 Joints and Adhesives

1.4.1 All joints shall be standard Mortise and tennon / dowel / dovetail / cross-halved /itred / tongue & groove / rebated. False Ceiling/Partition and wall cladding work andas per approval of the Project Manager / Architect.

1.5 Fastenings

1.5.1 Screws, nails etc, shall be of standard iron / wire unless otherwise shown ondrawings.

1.6 Hardware

1.6.1 Hinges, locks, latches, door tracks, nail hides etc shall be as specified or an approvedsubstitute equal to or better than the specified.

1.7 Metal

1.7.1 Where metal frames like are used, these shall be welded, brazed, bolted or asrequired, and on finished surfaces, welding, brazing, and riveting shall be ground sothat no evidence of this is apparent on the final finish of the metal.

1.8 Finish

1.8.1 Finishes shall be fully in accordance with the drawings and schedules. Where timberis in natural finish, pieces shall be matched for colour and grain before assembly.Where timber is stained the stain shall be matched throughout. Backs of wall-hungcase of ceiling and wall cladding shall be treated with an approved brand of woodpreservative.

1.9 THE RATES QUOTED SHALL BE INCLUDING ALL WASTAGES. THEMEASUREMENT WILL BE TAKEN ON THE LAID AREA AND FOR THE FINISHEDPRODUCT ONLY.

Page 69: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 69

1.10 MATERIAL ORDER STATUS / RECEIPTS AT SITE :The Contractor shall inform theProject Manager as regards the quantity & quality of the material received / availableon site. The Project Manager shall check the material stock for quantity as well asquality. He may or may not give any prior notice to the Contractor before such acheck. The Contractor shall ensure that the Project Manager has full access to hisstores at all times.

2.0 STANDARD WORKMANSHIP

2.1 To determine the acceptable standard of workmanship, the Contractor shall execute aportion of the items of work as sample, for approval of the Architect, before taking upthe actual execution of the particular item of work.

2.2 These samples, on approval of the Owner / Architect, shall be the guiding sample forexecution of the particular item of work. Work not conforming to the approvedsample shall be rejected. Rates quoted for the items shall include for suchpreliminary work and shall not be paid for separately.

3.0 CEILING WORK

3.1 GYPSUM BOARD (SUSPENDED CEILING REGULAR)

3.1.1 Suspended ceiling, which includes GI perimeter channels of size 0.55 thick along withperimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleevesand screws, at 610mm centres.

3.2 JOINTING & FINISHING

3.2.1 Finally square and tapered edges of the boards are to be jointed and finished so as tohave a flush look which includes filling and finishing with jointing compound, jointpaper tape and two coats of drywall top coat suitable for Gypboard (as perrecommended practices of BPB India Gypsum).

3.2.2 Alternatively all square & tapered edge joints to be filled with Universal Board finishplaster & joint paper tape is embedded to complete the first application. Finally 2mmthick Board finish plaster is applied on the entire surface of Gypboard to achievesmooth & seamless finish. The plaster application shall be carried out with BPB T & T,as per the recommended specification of BPB IGL.

3.2.3 For lighting fittings, grills, diffusers & cut-outs etc. have to be made with the frame ofperimeter channels, supported suitably & should be considered.

3.2.4 All steel sections shall be marked with ‘Gypsteel TM (registered trademark of BPBIGL) & Holograms

3.3 GYPSUM GRID CEILING

3.3.1 BPB Suspended grid system with galvanized steel ‘T’ section frame work of hotdipped galvanized steel pre-coated (exposed portion only), which includes flush fitting900mm long cross tees to be interlocked between main runners at 600mm centres toform 900 x 600mm modules. Cut cross tees longer that 600mm to be supported

Page 70: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 70

independently .600 x 600mm modules to be formed by fitting 600mm long flushfitting cross tees centrally between the 900mm cross tees.

3.4 DESCRIPTION

3.4.1 Suspension system: The BPB suspension system shall be of hot dipped pre-coatedgalvanized steel sections which includes the following members:

3.4.1.1 Main Runner: ‘T’ Section of size 38 x 24 x 0.35mm & 3.6mtr long3.4.1.2 Cross Runner: ‘T’ Section of size 25 x 24 x 0.30mm & 1.2mtr long3.4.1.3 Cross Runner: ‘T’ Section of size 25 x 24 x 0.30mm & 0.6mtr long3.4.1.4 Wall Angle: 24 x 24 x 0.45mm & 3.05mtr long

3.4.2 The ‘T’ section shall be suspended from the soffit with the help of soffit cleat, Rawlplug, and GI wire rod of 4mm dia with galvanized spring level clips at 900mmcenters.

3.5 BOARDING

3.5.1 8mm/9.5mm/12.5mm thick Gypboard ceiling panel of size 595mm x 595mm shall beplaced into the grid size of 600 x 600mm.

3.6 GLAZING

3.6.1 All glass is to be of approved manufacturer of approved quality and shall be free frombubbles, smokes, waves, air holes and other defects. The kind of glass to be usedshall be as mentioned in the item or specification or in the special provisions or asshown in detailed drawings. Thickness of glass panel shall be uniform. All glass to beapproved manufacture complying with IS: 3548 – 196 or as per approved quality andsample.

3.6.2 The compound for glazing to metal is to be special non-hardening compoundmanufacture for the purpose and of 9 brand and quality approved the EIC.

3.6.3 While cutting glass, proper allowance by made for expansion. Each square of glazingto be in one whole sheet. On completion of work, all glass shall be cleaned inside andoutside and all cracked scratched and broken panes shall be replaced and left in agood condition.

3.6.4 All exposed edges of glass shall be lead polished.

4.0 POST CAP METAL CEILING SYSTEM

4.1 METAL CEILING SYSTEM

4.1.1 Providing & fixing of Lindner LMD B 117 Post cap ceiling system Lindner-Germany/Bardiss make according to EN 13964 TAIM Quality standard made up of0.6 mm thick galvanized steel with swing down function, of size 1800X600 mm incombination with standard 100 mm wide Post cap 11/30/100/30/11 mm, 1.00 mmpre-galvanized steel, polyester powder coated RAL 9010 (white) , length: 3425 mmalong with end caps of post cap panels as per site requirement, square edge,perforated to Rv 1,8-20, electro statically applied powder coating of color RAL 9010with a Gloss rate of 20% with RAL 9010 and manufactured as per applicable EN13964/10152/10346. Substructure Components to be manufactured with cold rolledzinc galvanized steel in accordance with EN 13964/10152/10346 and EN ISO 12944.at position 10/15/65 Threaded rod DIN 976-1 M6 X length with hexagonal nut M6

Page 71: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 71

and zinc galvanized fender washer and fastening of threaded to rod suspension toconcrete slab by Hilti Anchor Fastener. Position no. 111 screwed to post cap crossingbox by means of self drilling screw, suspension by means of threaded rod and thepost cap size is 100 mm , The system should be in accordance with Material class A2-s1,d0 according to EN 13501-1 "non-combustible”, per the Direction of Arch-in-Charge

4.2 MATERIAL

4.2.1 Metal suspended corridor ceiling panel shall be manufactured from polyester powdercoated electro galvanized steel with perforated and plain surfaces supported by postcap profiles. The suspended ceiling shall comprise of suspension made up of/30/100/30/11 mm, 1.00 mm pre-galvanized steel, polyester powder coated RAL9010 (white), length: 3425 mm along with end caps of post cap panels, supported bysuspension allowing the panels to swing and slide providing maximum accessibility tothe void and all the perforated panels to be fitted with black acoustic tissue.

4.3 PANEL

4.3.1 The panel size is 1800X600-625 mm, panel with 0.6 mm thickness nominal.Manufactured from electro galvanized steel with square edges to all four sides withdrop down and slide function, Perforation patter Rv 1,8.20( 1.8 mm dia hole and 20%open area), polyester powder coated in RAL 9010 with minimum 60 micronsthickness shall be electro statically applied complete with factory fitted black acoustictissue along with the fixed panel of /30/100/30/11 mm, 1.00 mm pre-galvanizedsteel, polyester powder coated RAL 9010 (white) , length: 3425 mm along with endcaps of post cap panels manufactured from electro galvanized steel , polyesterpowder coated in RAL 9010 with minimum 60 microns thickness.

4.4 ACCESS

4.4.1 All the middle panels must be able to drop & slide and provide full and easy access tothe ceiling void

4.5 LEVEL

4.5.1 All the panels should be fitted to ensure accurate positioning & level of the ceilingsystem as per the site/architectural requirements.

4.6 GENERAL SUSUPENSION SYSTEM

4.6.1 The panels shall be supported by the suspension system Post cap 11/30/100/30/11mm, 1.00 mm pre-galvanized steel, polyester powder coated RAL 9010 (white) ,length: 3425 mm along with end caps of post cap panels as per site requirement,square edge, perforated to Rv 1,8-20, electro statically applied powder coating ofcolor RAL 9010 with a Gloss rate of 20% with RAL 9010 and manufactured as perapplicable EN 13964/10152/10346. Substructure Components to be manufacturedwith cold rolled zinc galvanized steel in accordance with EN 13964/10152/10346 andEN ISO 12944. at position 10/15/65 Threaded rod DIN 976-1 M6 X length withhexagonal nut M6 and zinc galvanized fender washer and fastening of threaded torod suspension to concrete slab by Hilti Anchor Fastener. Position no. 111 screwed topost cap crossing box by means of self drilling screw, suspension by means ofthreaded rod and the post cap size is 100 MM.

4.7 FINISH

Page 72: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 72

4.7.1 Finish of the ceiling tiles should be electro statically applied polyester powder coatedof minimum 60 microns with 20% gloss. Pre painted products will not be permitted.

4.8 FIRE PERFORMANCE

4.8.1 The system should be in accordance with Material class A2-s1, d0 according to EN13501-1 "non-combustible.

4.9 PROVISIONS FOR LIGHT AND OTHER FITTINGS

4.9.1 The panels will be cut on site for the provision of light fixtures and other fittings asper the directions of the Engineer In charge

4.10 MANUFACTURING TOLENRANCES

4.10.1 All the metal ceiling elements and the corresponding substructure should bemanufactured in accordance with ceiling standards accessed by EN 13964 & TAIM(Federation of Industrial Metal Ceiling Manufacturers).

4.11 GREEN BUILDING

4.11.1 The metal ceiling systems should be applicable for certifications in accordance toLEED & DGNB, Environmental product decelerations (EPD) to be submitted whenever asked.

4.12 WARRANTY CERTIFICATE

4.12.1 Manufacturer should submit the warranty certificate for the minimum 15 years.

4.13 MEASUREMENT

4.13.1 Length & breadth of the finished ceiling shall be measured correct to a centimeter.The area shall be calculated in square meter correct to two decimal places. Nodeduction shall be made for making openings for electrical, air conditioning, firefighting fixtures nor shall extra payment be made either for extra materials or labor inmaking such openings.

4.14 RATES

4.14.1 The rate shall include the cost of all the materials, machinery, manpower involved inall the operations described above including cartage, loading , unloading , all taxeslike VAT, service tax, custom duty etc except the scaffolding material and the erectionlabor cost

5.0 CANOPY METAL CEILING SYSTEM

5.1 METAL CEILING SYSTEM

5.1.1 Providing & fixing of canopy ceiling system made up of 0.7 mm thick galvanized steelof custom size as per site requirement, perforated to 1.8 mm and 20% open area(Rv1,8,20) Entire ceiling construction is to be carried out according to EN 13964, asper manufacturer specifications.

5.2 MATERIAL

Page 73: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 73

5.2.1 Metal suspended Canopy ceiling panel shall be manufactured from polyester powdercoated electro galvanized steel with perforated and plain surfaces., supported bysuspension allowing the panels to swing and slide providing maximum accessibility tothe void and all the perforated panels to be fitted with black acoustic tissue.

5.3 APPROVED SYSTEM

5.3.1 The panel size is custom shape panel with 0.7 mm thickness nominal. Manufacturedfrom electro galvanized steel with square edges to all four sides with drop down andslide function, Perforation patter Rv 1,8.20( 1.8 mm dia hole and 20% open area),polyester powder coated in RAL 9010 with minimum 60 microns thickness shall beelectro statically applied complete with factory fitted black acoustic tissue, polyesterpowder coated RAL 9010 (white) panels manufactured from electro galvanized steel ,polyester powder coated in RAL 9010 with minimum 60 microns thickness.

5.4 ACCESS

5.4.1 All the middle panels must be able to drop & slide and provide full and easy access tothe ceiling void

5.5 LEVEL

5.5.1 All the panels should be fitted to ensure accurate positioning & level of the ceilingsystem as per the site/architectural requirements.

5.6 GENERAL SUSUPENSION SYSTEM

5.6.1 The panels shall be supported by the suspension system of hook on system made upof galvanized steel.

5.7 FINISH

5.7.1 Finish of the ceiling tiles should be electro statically applied polyester powder coatedof minimum 60 microns with 20% gloss. Pre painted products will not be permitted.

5.8 FIRE PERFORMANCE

5.8.1 The system should be in accordance with Material class A2-s1, d0 according to EN13501-1 "non-combustible.

5.9 PROVISIONS FOR LIGHT AND OTHER FITTINGS

5.9.1 The panels will be cut on site for the provision of light fixtures and other fittings asper the directions of the Engineer In charge

5.10 MANUFACTURING TOLENRANCES

5.10.1 All the metal ceiling elements and the corresponding substructure should bemanufactured in accordance with ceiling standards accessed by EN 13964 & TAIM(Federation of Industrial Metal Ceiling Manufacturers).

5.11 GREEN BUILDING

Page 74: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 74

5.11.1 The metal ceiling systems should be applicable for certifications in accordance toLEED & DGNB, Environmental product decelerations (EPD) to be submitted whenever asked.

5.12 WARRANTY CERTIFICATE

5.12.1 Manufacturer should submit the warranty certificate for the minimum 15 years

5.13 MEASUREMENT

5.13.1 Length & breadth of the finished ceiling shall be measured correct to a centimeter.The area shall be calculated in square meter correct to two decimal places. Nodeduction shall be made for making openings for electrical, air conditioning, firefighting fixtures nor shall extra payment be made either for extra materials or labor inmaking such openings.

5.14 RATES

5.14.1 The rate shall include the cost of all the materials, machinery, manpower involved inall the operations described above including cartage, loading , unloading , all taxeslike VAT, service tax, custom duty etc except the scaffolding material and theerrection labor cost

6.0 CORRIDOR METAL CEILING SYSTEM

6.1 METAL CEILING SYSTEM

6.1.1 Providing and Fixing of Corridor Ceiling system (Drop & Slide System) The panelsshall be supported by the suspension system made from extruded drop & slide hookon profile, wall connection, 15 mm, aluminium, polyester powder coated RAL 9010 oflength 5000 mm along with perimeter trim 43/65/2mm, made up of steel polyesterpowder coated according to RAL 9010( of Lindner) of length 2500 mm in accordancewith EN 13964 /10152 and the length will be continued by using connector forextruded drop-slide hook on profile made up of 2.0 mm thick pre galvanized steel,supported by Hanger bracing , L angle of 2.0 mm thick GS( Electro-GalvanizedSteel) perforated angle of size 22/28 mm and length 6000 mm, Longitudinalconnector for hook on profile made up of 1.0 mm thick GMS( Electro-GalvanizedSteel)of size15X40X1 fixed to ceiling with dash fastener using 6mm thick threadedrods made up of galvanized steel attached to hook on profile carrier at 1200mmcentre to centre as required at site all complete The functional hook-on turn-upguarantees the drop-and-slide function of the metal ceiling panels. Riveted orscrewed parts are not permitted. By lifting, slight shifting and subsequent dropping,the metal ceiling panel can be locked into the lowest hook-on turn-up and movedhorizontally in both directions. Each metal ceiling panel can be dropped and movedindependently without the use of any tools. The system should be in accordance withMaterial class A2-s1, d0 according to EN 13501-1 "non-combustible” per the Directionof Arch-in-Charge

6.2 MATERIAL

6.2.1 Metal suspended corridor ceiling panel shall be manufactured from polyester powdercoated electro galvanized steel with perforated and plain surfaces supported inDouble and single hook on profiles. The suspended ceiling shall comprise ofsuspension made up of Extruded Aluminum & galvanized steel of 1.0 mm thickness,supported by suspension allowing the panels to drop and slide providing maximum

Page 75: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 75

accessibility to the void and all the perforated panels to be fitted with black acoustictissue

6.3 APPROVED SYSTEM

6.3.1 The middle panel size is 1800X300 mm, 2100X300mm, 2400X300mm for the dropand slide panel with 0.7 mm thickness nominal. Manufactured from electro galvanizedsteel with square edges to all four sides with drop down and slide function,Perforation patter Rv 1,8.20( 1.8 mm dia hole and 20% open area), polyester powdercoated in RAL 9010 with minimum 60 microns thickness shall be electro staticallyapplied complete with factory fitted black acoustic tissue along with the fixed panel ofsize 450X300 mm of 0,7 mm thickness manufactured from electro galvanized steel ,polyester powder coated in RAL 9010 with minimum 60 microns thickness.

6.4 ACCESS

6.4.1 All the middle panels must be able to drop & slide and provide full and easy access tothe ceiling void

6.5 LEVEL

6.5.1 All the panels should be fitted to ensure accurate positioning & level of the ceilingsystem as per the site/architectural requirements.

6.6 GENERAL SUSUPENSION SYSTEM

6.6.1 The panels shall be supported by the suspension system made from extruded drop &slide hook on profile, wall connection, 15 mm, aluminum, polyester powder coatedRAL 9010 of length 5000 mm along with perimeter trim 43/65/2mm, made up ofsteel polyester powder coated according to RAL 9010( of Lindner) of length 2500 mmin accordance with EN 13964 /10152 and the length will be continued by usingconnector for extruded drop-slide hook on profile made up of 2.0 mm thick pregalvanized steel, supported by Hanger bracing , L angle of 2.0 mm thick GS(Electro-Galvanized Steel) perforated angle of size 22/28 mm and length 6000 mm,Longitudinal connector for hook on profile made up of 1.0 mm thick GMS( Electro-Galvanized Steel)of size15X40X1 fixed to ceiling with dash fastener using 6mm thickthreaded rods made up of galvanized steel attached to hook on profile carrier at1200mm centre to centre as required at site all complete

6.7 FINISH

6.7.1 Finish of the ceiling tiles should be electro statically applied polyester powder coatedof minimum 60 microns with 20% gloss. Pre painted products will not be permitted.

6.8 FIRE PERFORMANCE

6.8.1 The system should be in accordance with Material class A2-s1, d0 according to EN13501-1 "non-combustible.

6.9 PROVISIONS FOR LIGHT AND OTHER FITTINGS

6.9.1 The panels will be cut on site for the provision of light fixtures and other fittings asper the directions of the Engineer In charge

6.10 MANUFACTURING TOLENRANCES

Page 76: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 76

6.10.1 All the metal ceiling elements and the corresponding substructure should bemanufactured in accordance with ceiling standards accessed by EN 13964 & TAIM(Federation of Industrial Metal Ceiling Manufacturers).

6.11 GREEN BUILDING

6.11.1 The metal ceiling systems should be applicable for certifications in accordance toLEED & DGNB, Environmental product decelerations (EPD) to be submitted whenever asked.

6.12 WARRANTY CERTIFICATE

6.12.1 Manufacturer should submit the warranty certificate for the minimum 15 years

6.13 MEASUREMENT

6.13.1 Length & breadth of the finished ceiling shall be measured correct to a centimeter.The area shall be calculated in square meter correct to two decimal places. Nodeduction shall be made for making openings for electrical, air conditioning, firefighting fixtures nor shall extra payment be made either for extra materials or labor inmaking such openings.

6.14 RATES

6.14.1 The rate shall include the cost of all the materials, machinery, manpower involved inall the operations described above including cartage, loading , unloading , all taxeslike VAT, service tax, custom duty etc except the scaffolding material and theerrection labor cost.

7.0 CLIP IN METAL CEILING SYSTEM

7.1 METAL CEILING SYSTEM

7.1.1 Providing and fixing perforated metal ceiling system of size 600X 1200 mm , clip insystem with swing down, 0.6 mm pre-galvanized steel. Finish of ceiling tiles shouldbe of special polyester powder coated RAL 9010 color of minimum 60 micronspowder coating thickness, perforations with hole diameter 2.5 mm and open area16%, with plain border and black tissue at back of the panel, supported by clip inprofile made of galvanized steel 0.60 mm and the suspension channel connectormade of galvanized 0.60 mm steel , length 100 mm along with hanger lower sectionfor suspension channel, hanger upper section for a ceiling void less than 500 mm,including safety pin self tapping screws etc. as approved by the Engineering- Charge

7.2 MATERIAL

7.2.1 Metal suspended corridor ceiling panel shall be manufactured from polyester powdercoated electro galvanized steel with perforated and plain surfaces supported inDouble and single hook on profiles., supported by suspension allowing the panels todrop and slide providing maximum accessibility to the void and all the perforatedpanels to be fitted with black acoustic tissue

7.3 APPROVED SYSTEM

7.3.1 The panel size is 600x1200 mm with 0.6 mm thickness nominal. Manufactured fromelectro galvanized steel with square edges to all four sides with drop down and slide

Page 77: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 77

function, Perforation patter Rv 1, 8.20(1.8 mm dia hole and 20% open area),polyester powder coated in RAL 9010 with minimum 60 microns thickness shall beelectro statically applied complete with factory fitted black acoustic tissue polyesterpowder coated in RAL 9010 with minimum 60 microns thickness.

7.4 ACCESS

7.4.1 All the middle panels must be able to drop & slide and provide full and easy access tothe ceiling void

7.5 LEVEL

7.5.1 All the panels should be fitted to ensure accurate positioning & level of the ceilingsystem as per the site/architectural requirements.

7.6 GENERAL SUSUPENSION SYSTEM

7.6.1 Clip in profile made of galvanized steel 0.60 mm and the suspension channelconnector made of galvanized 0.60 mm steel , length 100 mm along with hangerlower section for suspension channel, hanger upper section for a ceiling void lessthan 500 mm, including safety pin self tapping screws etc. as approved by theEngineering- Charge

7.7 FINISH

7.7.1 Finish of the ceiling tiles should be electro statically applied polyester powder coatedof minimum 60 microns with 20% gloss. Pre painted products will not be permitted.

7.8 FIRE PERFORMANCE

7.8.1 The system should be in accordance with Material class A2-s1, d0 according to EN13501-1 "non-combustible.

7.9 PROVISIONS FOR LIGHT AND OTHER FITTINGS

7.9.1 The panels will be cut on site for the provision of light fixtures and other fittings asper the directions of the Engineer In charge

7.10 MANUFACTURING TOLENRANCES

7.10.1 All the metal ceiling elements and the corresponding substructure should bemanufactured in accordance with ceiling standards accessed by EN 13964 & TAIM(Federation of Industrial Metal Ceiling Manufacturers).

7.11 GREEN BUILDING

7.11.1 The metal ceiling systems should be applicable for certifications in accordance toLEED & DGNB, Environmental product decelerations (EPD) to be submitted whenever asked.

7.12 WARRANTY CERTIFICATE

7.12.1 Manufacturer should submit the warranty certificate for the minimum 15 years

7.13 MEASUREMENT

Page 78: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 78

7.13.1 Length & breadth of the finished ceiling shall be measured correct to a centimeter.The area shall be calculated in square meter correct to two decimal places. Nodeduction shall be made for making openings for electrical, air conditioning, firefighting fixtures nor shall extra payment be made either for extra materials or labor inmaking such openings.

7.14 RATES

7.14.1 The rate shall include the cost of all the materials, machinery, manpower involved inall the operations described above including cartage, loading , unloading , all taxeslike VAT, service tax, custom duty etc except the scaffolding material and theerrection labor cost

8.0 METAL BAFFLE CEILING SYSTEM

8.1 METAL CEILING SYSTEM

8.1.1 Providing and fixing perforated open metal baffle ceiling system Polylam of Durlum,Linear Grid Lindner-Germany, Baffle panel 250mm X 30mmX1800mm X 0.6mm GMS.Perforated to Rg 2,5,16 pattern with 2.5mm dia hole providing 16% open area withsoundtex or equivalent tissue bonded at the back providing NRC not less than 0.7.The ceiling baffle units shall be installed at distance of 300 mm c/c in one direction.The baffle units are than attached to C Channel carrier made up of 0.6 mmgalvanized steel at 1200mm c/c. The C channel carrier are than cross connected toperforated L angle primarily Grid and suspended with M 6 threaded rod hangersspaced 1 200mm c/c, polyester post powder coated to RAL Color Black or white withminimum 60 micron paint thickness

8.2 MATERIAL

8.2.1 Metal suspended corridor ceiling panel shall be manufactured from polyester powdercoated electro galvanized steel with perforated and plain surfaces supported inDouble and single hook on profiles., supported by suspension allowing the panels todrop and slide providing maximum accessibility to the void and all the perforatedpanels to be fitted with black acoustic tissue

8.3 APPROVED SYSTEM

8.3.1 Providing and fixing perforated open metal baffle ceiling system Polylam of Durlum,Linear Grid Lindner-Germany, Baffle panel 250mm X 30mmX1800mm X 0.6mm GMS.Perforated to Rg 2,5,16 pattern with 2.5mm dia hole providing 16% open area withsoundtex or equivalent tissue bonded at the back providing NRC not less than 0.7.The ceiling baffle units shall be installed at distance of 300 mm c/c in one direction.

8.4 ACCESS

8.4.1 All the middle panels must be able to drop & slide and provide full and easy access tothe ceiling void

8.5 LEVEL

8.5.1 All the panels should be fitted to ensure accurate positioning & level of the ceilingsystem as per the site/architectural requirements.

Page 79: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 79

8.6 GENERAL SUSUPENSION SYSTEM

8.6.1 The baffle units are than attached to C Channel carrier made up of 0.6 mmgalvanized steel at 1200mm c/c. The C channel carrier are than cross connected toperforated L angle primarily Grid and suspended with M 6 threaded rod hangersspaced 1 200mm c/c, polyester post powder coated to RAL Color Black or white withminimum 60 micron paint thickness

8.7 FINISH

8.7.1 Finish of the ceiling tiles should be electro statically applied polyester powder coatedof minimum 60 microns with 20% gloss. Pre painted products will not be permitted.

8.8 FIRE PERFORMANCE

8.8.1 The system should be in accordance with Material class A2-s1, d0 according to EN13501-1 "non-combustible.

8.9 PROVISIONS FOR LIGHT AND OTHER FITTINGS

8.9.1 The panels will be cut on site for the provision of light fixtures and other fittings asper the directions of the Engineer In charge

8.10 MANUFACTURING TOLENRANCES

8.10.1 All the metal ceiling elements and the corresponding substructure should bemanufactured in accordance with ceiling standards accessed by EN 13964 & TAIM(Federation of Industrial Metal Ceiling Manufacturers)

8.11 GREEN BUILDING

8.11.1 The metal ceiling systems should be applicable for certifications in accordance toLEED & DGNB, Environmental product decelerations (EPD) to be submitted whenever asked.

8.12 WARRANTY CERTIFICATE

8.12.1 Manufacturer should submit the warranty certificate for the minimum 15 years

8.13 MEASUREMENT

8.13.1 Length & breadth of the finished ceiling shall be measured correct to a centimeter.The area shall be calculated in square meter correct to two decimal places. Nodeduction shall be made for making openings for electrical, air conditioning, firefighting fixtures nor shall extra payment be made either for extra materials or labor inmaking such openings.

8.14 RATES

8.14.1 The rate shall include the cost of all the materials, machinery, manpower involved inall the operations described above including cartage, loading , unloading , all taxeslike VAT, service tax, custom duty etc except the scaffolding material and theerrection labor cost

9.0 SINGLE GLAZING FULL HEIGHT PARTITION SYSTEM

Page 80: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 80

9.1 PARTITION SYSTEM

9.1.1 Providing & fixing of Single glazing full height partition frameless up to ceiling level(approx 2700 mm) of the applicable Standard DIN 18202, DIN 1249 DIN EN ISO12543. Framing shall be consist of Aluminum profile 40 mm( H) X wall thickness 28mm( Thickness) , Wall , Ceiling & Floor Connection made up of Anodized Aluminum.Above false ceiling, vertical sections to be extended up to main ceiling and to be fixedwith suitable accessories. Sound Insulation of 35 db to be achieved using 12 mmthick VSG toughened clear glasses of make Saint Gobain or equivalent according toDIN EN ISO 140-03, Joint width 3 mm. Complete in all respect with all suitableaccessories as per manufacturer standards. The item is to be finished complete in allrespects. (Tendered should visit the site and check the actual floor height – Partitionto be measured up to false ceiling height excluding door opening for Billing purpose)per the Direction of Arch-in-Charge

9.2 MATERIAL

9.2.1 Framing shall be consist of Aluminum profile 40 mm( H) X wall thickness 28 mm(Thickness) , Wall , Ceiling & Floor Connection made up of Anodized Aluminum. Abovefalse ceiling, vertical sections to be extended up to main ceiling and to be fixed withsuitable accessories. Sound Insulation of 35 db to be achieved using 12 mm thickVSG toughened clear glasses of make Saint Gobain or equivalent according to DIN ENISO 140-03, Joint width 3 mm

9.3 APPROVED SYSTEM

9.3.1 Single glazing full height partition frameless up to ceiling level (approx 2700 mm) ofthe applicable Standard DIN 18202, DIN 1249 DIN EN ISO 12543. Framing shall beconsist of Aluminum profile 40 mm( H) X wall thickness 28 mm( Thickness) , Wall ,Ceiling & Floor Connection made up of Anodized Aluminum. Above false ceiling,vertical sections to be extended up to main ceiling and to be fixed with suitableaccessories. Sound Insulation of 35 db to be achieved using 12 mm thick VSGtoughened clear glasses of make Saint Gobain or equivalent according to DIN EN ISO140-03, Joint width 3 mm. Complete in all respect with all suitable accessories as permanufacturer standards.

9.4 LEVEL

9.4.1 All the partition walls should be fitted to ensure accurate positioning & level of theceiling, flooring and wall system as per the site/architectural requirements.

9.5 GENERAL SUSUPENSION SYSTEM

9.5.1 Framing shall be consist of Aluminum profile 40 mm( H) X wall thickness 28 mm(Thickness) , Wall , Ceiling & Floor Connection made up of Anodized Aluminum.

9.6 FINISH

9.6.1 Finish of the frame should be anodized aluminum.

9.7 GREEN BUILDING

9.7.1 The metal ceiling systems should be applicable for certifications in accordance toLEED & DGNB, Environmental product decelerations (EPD) to be submitted whenever asked.

Page 81: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 81

9.8 WARRANTY CERTIFICATE

9.8.1 Manufacturer should submit the warranty certificate for the minimum 15 years

9.9 RATES

9.9.1 The rate shall include the cost of all the materials, machinery, manpower involved inall the operations described above including cartage, loading , unloading , all taxeslike VAT, service tax, custom duty etc except the scaffolding material and theerrection labor cost

10.0 SINGLE GLAZING FULL HEIGHT PARTITION SYSTEM( with metal panel)

10.1 PARTITION SYSTEM

10.1.1 Providing & fixing of Single glazing full height partition frameless with Solidperforated metal panels in Artline wood finish up to ceiling level (approx 2700 mm) ofthe applicable Standard DIN 18202, DIN 1249 DIN EN ISO 12543. Framing shall beconsist of Aluminum profile 40 mm( H) X wall thickness 28 mm( Thickness) , Wall ,Ceiling & Floor Connection made up of Anodized Aluminum. Above false ceiling,vertical sections to be extended up to main ceiling and to be fixed with suitableaccessories. Sound Insulation of 35 db to be achieved using 12 mm thick VSGtoughened glasses of make Saint Gobain or equivalent according to DIN EN ISO 140-03, Joint width 3 mm. Complete in all respect with all suitable accessories as permanufacturer standards. The item is to be finished complete in all respects.(Tendered should visit the site and check the actual floor height – Partition to bemeasured up to false ceiling height excluding door opening for Billing purpose) perthe Direction of Arch-in-Charge

10.2 MATERIAL

10.2.1 Framing shall be consist of Aluminum profile 40 mm( H) X wall thickness 28 mm(Thickness) , Wall , Ceiling & Floor Connection made up of Anodized Aluminum. Abovefalse ceiling, vertical sections to be extended up to main ceiling and to be fixed withsuitable accessories. Sound Insulation of 35 db to be achieved using 12 mm thickVSG toughened clear glasses of make Saint Gobain or equivalent according to DIN ENISO 140-03, Joint width 3 mm

10.3 APPROVED SYSTEM

10.3.1 Single glazing full height partition frameless up to ceiling level (approx 2700 mm) ofthe applicable Standard DIN 18202, DIN 1249 DIN EN ISO 12543. Framing shall beconsist of Aluminum profile 40 mm( H) X wall thickness 28 mm( Thickness) , Wall ,Ceiling & Floor Connection made up of Anodized Aluminum. Above false ceiling,vertical sections to be extended up to main ceiling and to be fixed with suitableaccessories. Sound Insulation of 35 db to be achieved using 12 mm thick VSGtoughened clear glasses of make Saint Gobain or equivalent according to DIN EN ISO140-03, Joint width 3 mm. Complete in all respect with all suitable accessories as permanufacturer standards.

10.4 LEVEL

10.4.1 All the partition walls should be fitted to ensure accurate positioning & level of theceiling, flooring and wall system as per the site/architectural requirements.

Page 82: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 82

10.5 GENERAL SUSUPENSION SYSTEM

10.5.1 Framing shall be consist of Aluminum profile 40 mm( H) X wall thickness 28 mm(Thickness) , Wall , Ceiling & Floor Connection made up of Anodized Aluminum.

10.6 FINISH

10.6.1 Finish of the frame should be anodized aluminum.

10.7 GREEN BUILDING

10.7.1 The metal ceiling systems should be applicable for certifications in accordance toLEED & DGNB, Environmental product decelerations (EPD) to be submitted whenever asked.

10.8 WARRANTY CERTIFICATE

10.8.1 Manufacturer should submit the warranty certificate for the minimum 15 years

10.9 RATES

10.9.1 The rate shall include the cost of all the materials, machinery, manpower involved inall the operations described above including cartage, loading , unloading , all taxeslike VAT, service tax, custom duty etc except the scaffolding material and theerrection labor cost

11.0 TIMBER WALL CLADDING

11.1 WALL CLADDING

11.1.1 Providing & fixing of Timber Wall Cladding made of frame of Galvanized Steelmaintaining minimum 40mm gap from the brick wall by using L angle, J profile,gasket strip, Hook in bracket & self tappings screw substructure with a gap of 600-1200mm c/c as per site requirement, which is to be fixed/ anchored as permanufactures specifications and cladded with 19mm thick Timber wood as per theDirection of Arch-in-Charge.

11.2 MATERIAL

11.2.1 Providing & fixing of Timber Wall Cladding made of frame of Galvanized Steelmaintaining minimum 40mm gap from the brick wall by using L angle, J profile,gasket strip, Hook in bracket & self tappings screw substructure with a gap of 600-1200mm c/c as per site requirement.

11.3 APPROVED SYSTEM

11.3.1 Timber Wall Cladding made of frame of Galvanized Steel maintaining minimum 40mmgap from the brick wall by using L angle, J profile, gasket strip, Hook in bracket & selftappings screw substructure with a gap of 600-1200mm c/c as per site requirement,which is to be fixed/ anchored as per manufactures specifications and cladded with19mm thick Timber wood as per the Direction of Arch-in-Charge.

11.4 LEVEL

Page 83: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 83

11.4.1 All the partition walls should be fitted to ensure accurate positioning & level of theceiling, flooring and wall system as per the site/architectural requirements.

11.5 GENERAL SUSUPENSION SYSTEM

11.5.1 Frame of Galvanized Steel maintaining minimum 40mm gap from the brick wall byusing L angle, J profile, gasket strip, Hook in bracket & self tappings screwsubstructure with a gap of 600-1200mm c/c as per site requirement, which is to befixed/ anchored

11.6 FINISH

11.6.1 Finish of the frame should be anodized aluminum.

11.7 GREEN BUILDING

11.7.1 The metal ceiling systems should be applicable for certifications in accordance toLEED & DGNB, Environmental product decelerations (EPD) to be submitted whenever asked.

11.8 WARRANTY CERTIFICATE

11.8.1 Manufacturer should submit the warranty certificate for the minimum 15 years

11.9 RATES

11.9.1 The rate shall include the cost of all the materials, machinery, manpower involved inall the operations described above including cartage, loading , unloading , all taxeslike VAT, service tax, custom duty etc except the scaffolding material and theerrection labor cost

12.0 DOUBLE GLAZING FULL HEIGHT PARTITION SYSTEM

12.1 PARTITION SYSTEM

12.1.1 Providing & fixing of double glazing full height partition frameless up to ceiling level(approx 2700 mm) of the applicable Standard DIN 18202, DIN 1249 DIN EN ISO12543. Framing shall be consist of Aluminium profile 35mm( H) X wall thickness 100mm( Thickness) , Wall , Ceiling & Floor Connection made up of Anodized Aluminium.Above false ceiling, vertical sections to be extended up to main ceiling and to be fixedwith suitable accessories. Sound Insulation of 47 db to be achieved using 12 mmthick VSG toughened clear glass of make Saint Gobain or equivalent according to DINEN ISO 140-03, Joint width 3 mm. Complete in all respect with all suitableaccessories as per manufacturer standards. The item is to be finished complete in allrespects. (Tendered should visit the site and check the actual floor height – Partitionto be measured up to false ceiling height excluding door opening for Billing purpose)per the Direction of Arch-in-Charge.

12.2 MATERIAL

12.2.1 Double glazing full height partition frameless up to ceiling level (approx 2700 mm) ofthe applicable Standard DIN 18202, DIN 1249 DIN EN ISO 12543. Framing shall beconsist of Aluminium profile 35mm( H) X wall thickness 100 mm( Thickness) , Wall ,Ceiling & Floor Connection made up of Anodized Aluminium. Above false ceiling,vertical sections to be extended up to main ceiling and to be fixed with suitableaccessories. Sound Insulation of 47 db to be achieved using 12 mm thick VSG

Page 84: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 84

toughened clear glass of make Saint Gobain or equivalent according to DIN EN ISO140-03, Joint width 3 mm.

12.3 APPROVED SYSTE

12.3.1 Double glazing full height partition frameless up to ceiling level (approx 2700 mm) ofthe applicable Standard DIN 18202, DIN 1249 DIN EN ISO 12543. Framing shall beconsist of Aluminium profile 35mm( H) X wall thickness 100 mm( Thickness) , Wall ,Ceiling & Floor Connection made up of Anodized Aluminium. Above false ceiling,vertical sections to be extended up to main ceiling and to be fixed with suitableaccessories. Sound Insulation of 47 db to be achieved using 12 mm thick VSGtoughened clear glass of make Saint Gobain or equivalent according to DIN EN ISO140-03, Joint width 3 mm. Complete in all respect with all suitable accessories as permanufacturer standards. The item is to be finished complete in all respects

12.4 LEVEL

12.4.1 All the partition walls should be fitted to ensure accurate positioning & level of theceiling, flooring and wall system as per the site/architectural requirements.

12.5 GENERAL SUSUPENSION SYSTEM

12.5.1 Framing shall be consist of Aluminium profile 35mm( H) X wall thickness 100 mm(Thickness) , Wall , Ceiling & Floor Connection made up of Anodized Aluminium.Above false ceiling, vertical sections to be extended up to main ceiling and to be fixedwith suitable accessories.

12.6 FINISH

12.6.1 Finish of the frame should be anodized aluminum.

12.7 GREEN BUILDING

12.7.1 The metal ceiling systems should be applicable for certifications in accordance toLEED & DGNB, Environmental product decelerations (EPD) to be submitted whenever asked.

12.8 WARRANTY CERTIFICATE

12.8.1 Manufacturer should submit the warranty certificate for the minimum 15 years

12.9 RATES

12.9.1 The rate shall include the cost of all the materials, machinery, manpower involved inall the operations described above including cartage, loading , unloading , all taxeslike VAT, service tax, custom duty etc except the scaffolding material and theerrection labor cost

13.0 DOUBLE LAYER WOODEN PANEL PARTITION SYSTEM

13.1 PARTITION SYSTEM

13.1.1 Providing & fixing of Double layer of Wooden panel in combination of Glass panel /fullwooden panel framing up to ceiling level( approx 2700 mm ) of the applicablestandard DIN 18202 , DIN 68100.Framing shall be consist of 35 mm X 100 mm, Wall, Ceiling , Floor connections made up of 1.5 thick roll deformed, galvanized steel.

Page 85: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 85

Above false ceiling, vertical sections to be extended up to main ceiling and to be fixedwith suitable accessories. 25-50 mm thick & with 48Kg cubic meter density glass woolto be filled in between the two 19 mm thick timber wood panels to achieve the 50 dbsound insulation according to DIN EN ISO 140-03. Complete in all respect with allsuitable accessories as per manufacturer standards. The item is to be finishedcomplete in all respects. The above item should be as per specification and sampleapproved by client.

13.2 MATERIAL

13.2.1 Double layer of Wooden panel in combination of Glass panel /full wooden panelframing up to ceiling level( approx 2700 mm ) of the applicable standard DIN 18202 ,DIN 68100.Framing shall be consist of 35 mm X 100 mm, Wall , Ceiling , Floorconnections made up of 1.5 thick roll deformed, galvanized steel. Above false ceiling,vertical sections to be extended up to main ceiling and to be fixed with suitableaccessories. 25-50 mm thick & with 48Kg cubic meter density glass wool to be filledin between the two 19 mm thick timber wood panels to achieve the 50 db soundinsulation according to DIN EN ISO 140-03.

13.3 APPROVED SYSTEM

13.3.1 Double layer of Wooden panel in combination of Glass panel /full wooden panelframing up to ceiling level( approx 2700 mm ) of the applicable standard DIN 18202 ,DIN 68100.Framing shall be consist of 35 mm X 100 mm, Wall , Ceiling , Floorconnections made up of 1.5 thick roll deformed, galvanized steel. Above false ceiling,vertical sections to be extended up to main ceiling and to be fixed with suitableaccessories. 25-50 mm thick & with 48Kg cubic meter density glasswool to be filled inbetween the two 19 mm thick timber wood panels to achieve the 50 db soundinsulation according to DIN EN ISO 140-03. Complete in all respect with all suitableaccessories as per manufacturer standards

13.4 LEVEL

13.4.1 All the partition walls should be fitted to ensure accurate positioning & level of theceiling, flooring and wall system as per the site/architectural requirements.

13.5 GENERAL SUSUPENSION SYSTEM

13.5.1 Framing shall be consist of 35 mm X 100 mm, Wall, Ceiling, Floor connections madeup of 1.5 thick roll deformed, galvanized steel. Above false ceiling, vertical sections tobe extended up to main ceiling and to be fixed with suitable accessories. 25-50 mmthick & with 48Kg cubic meter density glasswool to be filled in between the two 19mm thick timber wood panels.

13.6 FINISH

13.6.1 Finish of the frame should be anodized aluminum.

13.7 GREEN BUILDING

13.7.1 The metal ceiling systems should be applicable for certifications in accordance toLEED & DGNB, Environmental product decelerations (EPD) to be submitted whenever asked.

13.8 WARRANTY CERTIFICATE

Page 86: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 86

13.8.1 Manufacturer should submit the warranty certificate for the minimum 15 years

13.9 RATES

13.9.1 The rate shall include the cost of all the materials, machinery, manpower involved inall the operations described above including cartage, loading , unloading , all taxeslike VAT, service tax, custom duty etc except the scaffolding material and the erectionlabor cost.

SCOPE OF WORK IS DETAILED IN BILL OF QUANTITY (BOQ) & TENDERDRAWINGS (REFER FORM 1-D OF SCHEDULE OF PRICES). IN CASE OF ANYCONFLICT WITH THE GENERAL SPECIFICATION SPECIFIED ABOVE AND THE BILLOF QUANTITY(BOQ) AS PER FORM-1D, THE TECHNICAL SPECIFICATIONMENTIONED IN BILL OF QUANTITY ( FORM 1 D) SHALL PREVAIL.

Page 87: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 87

TECHNICAL SPECIFICATION FOR SYSTEM INTEGRATION WORK

Page 88: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 88

TECHNICAL SPECIFICATION FOR SYSTEM INTEGRATION WORK FOR VARIOUSBUILDINGS AT OTPC, PALATANA

1. DISPLAY SYSTEM

i. Full HD LED Display of 55"with Wall mount / Table mount or Full HD LED Display of 42"with Wall mount / Table mount

ii. DLP HD Projection system of 4500 Lumens, 350W, 3000:1, Standard Lens, Color Wheel,Horizontal Frequency: 15,30 - 90kHz; Vertical Scan Rate: 43 - 85 Hz; Keystone Correction:±15° Vertical.

iii. Motorized Lift for above projector

iv. Motorized-electrically operated Matte White finished projection screen of 65” x 116" [133"Diagonal] size, flame retardant and mildew with minimum viewing angle 60 degrees, Gain1.0. Shall have specially designed motor mounted inside the roller with noise silencer,three wire quick reversal type, oiled for life, with automatic thermal overload cut-out, pre-set but adjustable limit switches, with black masking borders standard. Bottom of fabricshall be formed into a pocket holding metal rod. Case to be 21-gauge powder coated steel,hexagon in shape with flat back, complete with three position control switch in box withcover plateRelay Interface for Up-Down movement of Motorized Projection Screen

2. SOURCE EQUIPMENTS

i. 1+ 5 party HD Point to Multipoint Video Conferencing System consisting of--Omni Directional Microphone--10X optical zoom Full HD Camera--PC for Presentation sharing--Inbuilt recording on Memory stick feature

ii. 16 port 10/100/1000 Mbps Layer2 Giga Network Switch

iii. DVD and HDD recorder features a HD Digital Tuner, 320GB HDD, 1080p up scaling viaHDMI and MP3 Juke Box

3. AUDIO RE-INFORCEMENT SYSTEM

i. Embedded Boundary Microphones on conference table

ii. Digital Signal Processor with echo canceller for minimum 16 audio inputs

iii. Feedback suppressor with built-in automatic mixer for the two microphone inputs shouldautomatically adapts up to 12 dB additional gain before feedback occurs in the acousticalsituation,

iv. Multi-Channel Amplifier

v. Speaker System

vi. Volume and audio source selector panel

Page 89: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 89

4. CONTROL SYSTEM

i. Integrated Control System for presentation and co-ordination between various audio-videoand lighting control services through 5.2" Active Matrix Display featuring VoIP Intercom,256 MB Flash / 128MB Standard SDRAM Memory, integrated battery, integrated kickstand& (1) PS3.0 Power Supply and Integrated NetLinx Controller with 404 MIPS Processor,64MB RAM, 128 MB of FLASH. 8 IR Ports, 8 I/O Ports, 8 Relays, and 7 RS-232 / 422 / 485Ports

ii. Dimmer / Light Control system for Presentations

iii. Multiformat Transmitter with receiver for 2 x Laptop and 1 x VC Connectivities.

iv. HDMI Matrix switcher of minimum 6 in and 6 out or more with Max. Data Rate 2.25Gbpsper graphic channel, HDCP Compatible, HDTV Compatible, HDMI Support HDMI (V.1.4with 3D, Deep Color, x.v.Color), 3D Pass-Through, reclocks and equalizes the signal andcan route any input to any or all outputs simultaneously.

v. HDMI Transmitter with Receiver for Display System (55" LED Display and Projector)

vi. HDMI Audio De−Embedder with 1xHDMI, 1xS/PDIF, 1xTOSLINK and 1xStereo (U) outputsfor Multi-media output of laptop presentation

5. CABLES AND CONNECTORS

i. High−performance 1.5M HDMI (M) to HDMI (M) patch cord with molded HDMI connectorsat both ends and with Ethernet Support :• High Data Transfer Rate Up to 10.2Gbps.•Supported Resolutions 720p/1080i/1080p Ideal for connecting HD devices to HD/full HDplasma/LCD, PSP3, Blu−ray and HD DVD.• Deep Color Supports 24−bit, 30−bit, 36−bitand 48−bit (RGB or YCbCr) color depths.• Multi-Channel Audio Support - Supports audiostream for external decoding by AV receivers and automatic audio syncing capabilities.•High Quality Connectors Gold−plated connectors resist corrosion.

ii. 1.5M VGA+A molded Patch cord complete with connectors

iii. 1.5M molded Audio Cable complete with connectors

iv. Audio / Speaker cable, Twisted pair stranded 26/30 (16 AWG) copper, designed forconnecting speakers and amplifiers

v. Four pair individually aluminum−foil shielded twisted pair, cabled with a drain conductorand overall braid−shielded -23AWG Control Cable

vi. Four pair individually aluminum−foil shielded twisted pair (S/FTP), cabled with a drainconductor and overall braid−shielded -23AWG Data Cable designed for twisted pair digitaltransmitter − receiver sets to provide optimum range and performance for 10GBase−Tapplications as defined in IEEE 802.3an and for PoE+ suitable for terminated with shieldedRJ−45 connectors

vii. Shielded RJ-45 Crimp Connector for 23 AWG Cable

viii. 1.5M power molded Cable complete with connectors

6. OTHER MISCELLANEOUS ITEMS

Page 90: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 90

i. 19" Equipment Rack of 24U

ii. Online UPS of 3 KVA with 30 minutes back-up

7. AUDIO VIDEO SYSTEM FOR 100 SEATER AUDITORIUM

7.1 DIGITAL PODIUM CONSISTING OF: -

i. 1/3" CCD imaging camera for digital podium with 1280 x 960 resolution, 720p format,12X optical zoom, capable to view as small as 10mm and 260mm large objects, LED lightsource, USB & LAN connectivities, capable to switch between Camera display and PCimages, complete in all respect & as per specifications.

7.2 PROFESSIONAL AUDIO SYSTEM CONSISTING OF: -

i. wall mount main FOH speakers loudspeaker with permanent install single 15" LF, single1.25" or more HF driver with Frequency Response (-10 dB) 45 Hz - 20 kHz and theSensitivity of 98 dB or more ( 1W/1m) delivering a Max SPL 131 dB or more. Theloudspeaker should have a horizontal coverage angle of 90 degree or better. It shouldhave Power handling continuous.600-800Watt.The loudspeaker should have integratedbracket or min 10 suspension points for permanent installation complete in all respect & asper specifications.

ii. Wall mount main Delay speakers with Permanent install, flying, single 12" Full Range 2Way loudspeaker. The loudspeaker should have frequency range (-10dB) of 55Hz-20kHz.Itshould have sensitivity (1W/1m) of 99 dB delivering Max SPL of 129dB or more. Theloudspeaker should a nominal impedance of 8 ohms and it should have with powerhandling pk of 1200W or more. The speaker must be a permanent install loudspeaker witha min of 4 or more integrated suspension points complete in all respect & as perspecifications.

iii. Subwoofer speaker with permanent installed, single 18" LF .It should have a Freq. Range(-10 dB) of 50 Hz - 600Hz Hz. It should have a sensitivity of (1W/1m) 99 dB or moredelivering max calculated SPL of 131 dB or more. The loudspeaker should have a nominalimpedance of 8ohm and Power Handling pk. of 4000W or more complete in all respect &as per specifications.

iv. Stage Monitor speaker with in-built amplifier having 12" LF ,1" or more HF with frequencyrange of 55Hz - 20kHz (-10dB) or better delivering a max SPL 131dB SPL .It should havehorizontal and vertical coverage angle of 90 degree and 50 degree or better. Theloudspeaker should have inbuilt amplifier of class D delivering a power of 1000W or more.It should have integrated monitor angle on the enclosure for use floor monitor complete inall respect & as per specifications.

v. Wall mount loudspeaker with dual 3.5" LF or more, single 0.75"HF driver with Built-in LMT.It should have Frequency Response (-10 dB) of 90 Hz - 20 kHz. The loudspeaker shouldhave a sensitivity( 1W/1m) of 85 dB or more delivering a Max SPL 106 dB or more withHorizontal and Vertical coverage angle of 90 -120 degree and 60-90 degree respectively.The loudspeaker should have power handling pk of 300 Watt. The loudspeaker shouldhave in-built LMT with power tap settings of 70V/100V:10W or more .It should haveintegrated mounting bracket for permanent installation complete in all respect & as perspecifications.

vi. Class H Dual channel power amplifier with specification as below or BETTER to suit thepower requirement of proposed speakers;Max Midband Output Power:1150W @ 4 ohms,1750W @ 2 ohms, Max Bridged Output

Page 91: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 91

Power:3600W @ 4 ohms, Frequency Response:20Hz - 20 KHz, THD:<0.03%,Max inputlevel:+21dBu,Crosstalk<80dB,input impedence:20kohm,signal to noise ratio : >110dB,with built in protection such as Audio Limiters, Temperature, DC, HF Short Circuit, PeakCurrent protections complete in all respect & as per specifications.

vii. Dual channel power amplifier with specification as below or BETTER to suit the powerrequirement of proposed speakers;Max Midband Output Power:550W @ 4 ohms,600W @ 2 ohms, Max Bridged OutputPower:1250W @ 4 ohms, Frequency Response:20Hz - 20 KHz, THD:<0.03%,Max inputlevel:+20dBu,Crosstalk<80dB,input impedence:20kohm,signal to noise ratio : >108dB,with built in protection such as Audio Limiters, Temperature, DC, HF Short Circuit, PeakCurrent protection complete in all respect & as per specifications.

viii. Single channel power amplifier for Control Room Speakers with specification as below orBETTER to suit the power requirement of proposed speakers;Rated Output Power:250W@70V/100V ,Frequency Response:70Hz -20KHz,THD:<0.5%,Max input level:+21dBu,input impedence:20kohm,,with built inprotection such as Audio Limiters, Temperature protection, Peak Current protectionscomplete in all respect & as per specifications.

ix. 100 W volume control for Speakers at Green room and control complete in all respect &as per specifications.

x. Digital Signal Processor with 2 x XLR IN, electronically balanced audio input,6 x XLR OUT,electronically balanced audio output with 2 x XLR Thru out ,and 1x XLR AES/EBU IN digitalinput, with Nominal Input Voltage:1.23V / +4 dBu, maximum input voltage:8.7V / +21dBu, input impedance :10k Ohm, CMR:-80dB@1kHz,A/D &D/A conversion :24 bit sigmadelta,THD+N <0.01% complete in all respect & as per specifications.

xi. 10 channel Mixer with Digital Audio interface with 4 input channel & 4 output channelswith AD/DA conversion 24-bit and; USB 2.0 PC Interface, MIDI interface, OLEDdisplay;100 Digital effects presets with at least 20 user preset available. 6 mono & 4 stereochannels, 6 auxiliary outputs, 11 band stereo equalizer; THD (at 1kHz) <0.005%,frequency response (-3dB):20Hz to 65kHz; crosstalk >85dB, CMRR (at 1kHz)>80dB,Equivalent input noise:-130dBu A, maximum level Mic inputs: +21dBu complete in allrespect & as per specifications.

xii. Handheld Wireless Mic system that has a min of 14-hour battery life from two AA alkalinebatteries. Cardiod polar pattern, Dynamic microphone ,frequency response 83Hz-18kHz,RFsensitivity < 1.0 Uv, Image rejection>55dB,Dyanmic range >95dB and receiver having 30channels possible, S/N ratio >100dB A, dynamic range >95db B, distortion <1%,frequency band:618-634MHz,modulation:+/-40kHz complete in all respect & as perspecifications.

xiii. Wireless Lapel Mic system that has a min of 14-hour battery life from two AA alkalinebatteries. Cardiod polar pattern, Dynamic microphone , frequency response 83Hz-18kHz,RF sensitivity < 1.0 Uv, Image rejection >55dB, Dynamic range >95dB and receiverhaving 30 channels possible, S/N ratio >100dB A, dynamic range >95db B, distortion <1%,frequency band: 618-634MHz,modulation:+/-40kHz complete in all respect & as perspecifications.

xiv. Gooseneck Mic with XLR base for podium having back electret condenser microphoneelement ,Hyper Cardioid polar pattern, programmable switch, frequency response 55Hz-20kHz ,sensitivity 5.5mV/Pa, clipping level >130dB SPL, output impendence 200 ohmcomplete in all respect & as per specifications.

Page 92: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 92

xv. feedback suppressor with built-in automatic mixer for the two microphone inputs shouldautomatically adapts up to 12 dB additional gain before feedback occurs in the acousticalsituation, complete in all respect & as per specifications.

7.3 PRESENTATION SWITCHER WITH SCALER & TOUCH CONTROL SYSTEM: -

i. Integrated Control System for presentation and co-ordination between various audio-videoand lighting control services through 5.2" Active Matrix Display featuring VoIP Intercom,256 MB Flash / 128MB Standard SDRAM Memory, integrated battery, integrated kickstand& (1) PS3.0 Power Supply andIntegrated NetLinx Controller with 404 MIPS Processor, 64MB RAM, 128 MB of FLASH. 8 IRPorts, 8 I/O Ports, 8 Relays, and 7 RS-232/422/485 Ports complete in all respect & as perspecifications.

ii. Furniture-Mountable durable, metal enclosure for Cables, AAPs, and AC Power Outletswith dimension of 6.96" W x 6.96" D (17.68 cm W x 17.68 cm D) that can be mountedinto a tabletop or other flat surface with a Blank anodize finish and a single Universal typepower outlet complete in all respect & as per specifications

iii. Cable Cubby AC Universal Power Module complete in all respect & as per specifications.

iv. Two-input automatic switcher HDCP compliant transmitter wall plate for sending HDMI orRGBHV video, audio, and Ethernet up to 330 feet (100 m) over a single CAT 5-type cable.The unit offered can be remotely powered. It should be able to support signal withresolutions of 1920 x 1200 including 1080p/60 with the data rates up to 6.75 Gbps, DeepColor up to 12-bit, 3D, HD lossless audio formats, and CEC complete in all respect & as perspecifications.

v. Long Distance XTP Receiver for HDMI; HDCP compliant; able to support 1080p / 60 DeepColor and 1920x1200 video signals, HDMI data rates up to 6.75 Gbps with deep color, 3Dand HD Audio; HDMI audio de-embedding with analog stereo and digital S/PDIF audiooutputs; local Analog audio also; bidirectional RS-232 and IR up to 330 feet (100 m) overa single CAT 5-type cable; capable of remote powering complete in all respect & as perspecifications.

vi. HDMI Matrix Switcher, should support computer-video to 1920x1200, including HDTV1080p / 60; HDMI; data rates up to 6.75 Gbps, Deep Color up to 12-bit, 3D, and HD audioformats, automatic cable equalization for each input to 100 feet (30 meters) at 1920 x1200 / 8-bit color; Speed Switching for HDCP-encrypted content; Key Minder forcontinuously verifying HDCP compliance; EDID Minder should automatically manage EDIDcommunication between connected devices; Automatic output re-clocking to Reshape andrestore timing of HDMI signals at each output, enabling transmission over long HDMIcables; Interface Format Correction; capability to separate an embedded audio signal fromits corresponding video signal within the matrix switcher, allowing the audio and videosignals from one source to be switched to different destinations; should provide +5 VDC,250 mA power on the HDMI outputs for external peripheral devices complete in all respect& as per specifications.

vii. HDMI Audio De-Embedder, Supports HDCP, HDMI audio de-embedding with analog stereoand digital S/PDIF audio outputs; data rates up to 6.75 Gbps, Deep Color up to 12-bit, and3D, Cable equalization at input; EDID Minder automatically manages EDID communicationbetween connected devices; LED indicators for HDCP confirmation, signal, Link status andPower Complete in all respect & as per specifications.

Page 93: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 93

viii. Long Distance XTP Transmitter for HDMI; It should be HDCP compliant and able tosupport 1080p/60 Deep Color and 1920x1200 video signals, HDMI audio embeddingwith analog stereo audio, local Analog audio also. Ethernet, remote power, bidirectionalRS-232 and IR up to 330 feet (100 m) over a single CAT 5-type cable; HDMI data rates upto 6.75 Gbps with deep color, 3D and HD Audio; capable of remote powering complete inall respect & as per specifications.

ix. Long Distance XTP Scaling Receiver, Twisted pair HDCP compliant receiver unit that scalesHDMI, DVI, RGB, HD component video, and standard definition video to the optimaloutput resolution for the display. It should accept video, audio, bidirectional RS-232 andIR, and Ethernet up to 330 feet (100 m) over a single CAT 5-type cable with selectableoutput rates from 640 x 480 to 1920 x 1200, including HDTV 1080p / 60; should supportdata rates up to 6.75 Gbps, Deep Color up to 12-bit, HD lossless audio formats, and CECalso to support various HDMI audio formats and is capable to de-embed them from HDMIin form of Analog Stereo or S/pdif digital format with audio adjustments and muting. Theunit should be controllable via USB or Rs-232 complete in all respect & as perspecifications.

x. 9.7‑inch (diagonal) color touch screen or bigger LED-backlit glossy widescreenMulti‑Touch display with 1024-by-768 resolution at 132 pixels per inch (ppi), support Wi-Fi(802.11a/b/g/n) and Bluetooth 2.1 + EDR technology, should have at least 16GB ofstorage memory; Built in speakers for video preview complete in all respect & as perspecifications.

xi. Touch Panel Control Device License.

7.4 PROJECTION SYSTEM CONSISTING OF: -

i. LCD / DLP Multimedia Projector with minimum of 6500 ANSI Lumens, HorizontalFrequency 30-90 KHz, Vertical scan rate 50-85Hz, image size 40" - 500"; Keystonecorrection of Vertical: ±40° , Horizontal: ±35°degree and complete in all respect withwired and wireless between PC and Projector complete in all respect & as perspecifications.

ii. Ceiling stand for Projection System complete in all respect etc as required complete in allrespect & as per specifications.

iii. Motorized-electrically operated Matte White finished projection screen of 57.5” x 92" [109"Diagonal] size, flame retardant and mildew with minimum viewing angle 60 degrees, Gain1.0. Shall have specially designed motor mounted inside the roller with noise silencer,three wire quick reversal type, oiled for life, with automatic thermal overload cut-out, pre-set but adjustable limit switches, with black masking borders standard. Bottom of fabricshall be formed into a pocket holding metal rod. Case to be 21-gauge powder coated steel,hexagon in shape with flat back, complete with three position control switch in box withcover plate complete in all respect & as per specifications.Relay Interface for Up-Down movement of Motorized Projection Screen

7.5 CABLES & CONNECTORS: -

i. Cat6 Cable in existing media complete in all respect & as per specifications.

ii. Control Cable in existing media complete in all respect & as per specifications.

iii. Speaker Cable in existing media complete in all respect & as per specifications.

iv. Microphone Cable in existing media complete in all respect & as per specifications.

Page 94: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 94

v. RGBHV Cable in existing media complete in all respect & as per specifications.

vi. RG59 Video Cable in existing media complete in all respect & as per specifications.

vii. 3 core 2.5 Sq. mm copper conductor power cables in existing media complete in allrespect & as per specifications.

viii. XLR Socket / Connector with Suitable Accessories

ix. Speaker Socket / Connector with Suitable Accessories

x. Phono Socket / Connector with Suitable Accessories

8.0 DISPLAY SYSTEM FOR LECTURE HALL SOLUTION

i. Interactive Ultra-short-throw DLP Projection System for classroom usage, 3000 lumens ofbrightness with 2,500:1 contrast ratio, Native resolution 1280 x 800, Throw ratio 0.19:1,16:10 Native, 4:3, 16:9 Compatible, manually adjustable for Image Size (Diagonal) 87" to97"

ii. Wall mount Kit for Short throw Projection system

iii. Interactive White-board of 103” active diagonal size suitable for above projection systemwith Aspect Ratio of 16:9

iv. Multiformat Transmitter with receiver for 1 x Laptop and 1 x White Board Connectivity.

v. Cables and Connectors

9.0 AUDIO RE-INFORCEMENT SYSTEM FOR EXECUTIVE TRAINING ROOM

i. Hand-held wireless microphone system

ii. Gooseneck Mic with XLR base for podium having back electret condenser microphoneelement ,Hyper Cardioid polar pattern, programmable switch, frequency response 55Hz-20kHz ,sensitivity 5.5mV/Pa, clipping level >130dB SPL, output impendence 200 ohm

iii. HDMI Audio De−Embedder with 1xHDMI, 1xS/PDIF, 1xTOSLINK and 1xStereo (U) outputsfor Multi-media output of laptop presentation

iv. Feedback suppressor with built-in automatic mixer for the two microphone inputs shouldautomatically adapts up to 12 dB additional gain before feedback occurs in the acousticalsituation,

v. Dual channel (Stereo) Audio Amplifier & Switcher (40 Watts per Channel) 1 Stereo (B) 1Stereo (U)

vi. Volume controller for two channels of balanced stereo audio signals on XLR connectors

vii. 2−way co−axial Closed−Back Ceiling Speakers (4Ω) Closed Back Can with Woofer − 4",Tweeter − 1", Freq − 20Hz to 20kHz, Crossover Frequency 10kHz, Sensitivity 85dB.,Frequency Response 85Hz to 20kHz., Power Rating 20W nominal, 40W Max

viii. Cables and Connectors

Page 95: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 95

10.0 BACKGROUND MUSIC SYSTEM FOR CANTEEN

i. Mixer Amplifier, minimum 60 W 100/70V Speaker out.

ii. Booster Amplifier, minimum 240 W 100/70V Speaker out.

iii. Handheld Wireless microphone

iv. economic flush-mounting ceiling full range loudspeaker for speech and music reproduction,Complies to Safety acc. to EN 60065 Emergency acc. to BS 5839-8 / EN 60849,,Ratedpower 6 / 3 / 1.5 / 0.75 W, Sound pressure level at 6 W / 1 W (4 kHz, 1 m)102 dB / 94 dB(SPL),Effective frequency range (-10dB) 80 Hz to 18 kHz, Opening angle at 1 kHz / 4 kHz(-6 dB) 160° / 65°

v. 100W volume control used to adjust the level locally, Built-in 24 VDC override relay,complies to Safety acc. to EN 60065 Self-extinguishing acc. to UL 94 V0 std, Frequencyresponse 50 Hz to 20 kHz (-1 dB)

vi. Housing for Volume control

vii. CD player, able to play MP3, WMA audio files with USB input.

viii. Equipment Rack with lockable and front perforated doors.

ix. 2 Core speaker cum control wire in existing media

x. 3 core 1.5M molded power cable

xi. 3 core power cable in existing media

SCOPE OF WORK IS DETAILED IN BILL OF QUANTITY (BOQ) & TENDERDRAWINGS (REFER FORM 1-D OF SCHEDULE OF PRICES). IN CASE OF ANYCONFLICT WITH THE GENERAL SPECIFICATION SPECIFIED ABOVE AND THE BILLOF QUANTITY(BOQ) AS PER FORM-1D, THE TECHNICAL SPECIFICATIONMENTIONED IN BILL OF QUANTITY ( FORM 1 D) SHALL PREVAIL. THE SYSTEMINTEGRATION WORK SHALL BE EXECUTED BY THE SYSTEM INTEGRATORSAPPROVED BY OTPC.

Page 96: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 96

ANNEXTURE-ILIST OF INDIAN STANDARDS

I.S. No. 900 – Latest measurement of building and civil engineering work.I.S. No. 287 – 1973.

Recommendation for maximum permissible moisture content of Tiber used fordifferent purposes in different climatic zones.

I. S. No. 1141 – 1973 code of practice for seasoning of timber.I. S. No. 6534 – 1971 guiding principles for grading and inspection of timber.I. S. No. 900 (Part XXI) 1973

Method of measurement of building and civil engineering works. Part XXI wood workand joinery.

I. S. No. 3845 – 1966. Code of practice for joints used in wooden furniture.I. S. No. 4000 – 1967. Wooden flush doors. Type to method of test for.I. S. No. 4970 – 1973. Key for identification of commercial timbers.I. S. No. 3364 (Part II) – 1975, Method of measurement and evaluation of defects intimber, part II converted timber.I. S. No. 1708 – 1969. Method of testing small clear specimens of timber.I. S. No. 6342 – 1971. Rose wood logs for production of sliced veneers.I. S. No. 5248 – 1969. Teak logs for production of sliced veneers.I. S. No. 2202 (Part I) 1973. Specification for wooden flush door shutters (solid core typepart I plywood)I. S. No. 2338 (Part I) – 1967. Code of practice for finishing of wood and wood basedmaterials part I operations and workmanship.I. S. No. 7630 – 1975. Methods of sampling of plywood.I. S. No. 303 – 1975. Specification for plywood for general purposes.I. S. No. 3129 – 1965. Specification for article board for insulation purposes.I. S. No. 3513 – 1966. (Part I. S. No. & part IV). High and medium density wood basedlaminates part I. S. No. general purposes. Part IV sampling test.I. S. No. 1659 – 1979 block boards.I. S. No. 7316 – 1974. Decorative plywood using plurality or veneers for decorative faces.I. S. No. 3478 – 1966. High density wood particle boards.I. S. No. 1734 (part I to XX). Plywood method of test for

Part I... GeneralPart II... PlywoodPart III… Battens

I. S. No. 1328 – 1970. Veneer decorative plywood.I. S. No. 710 – Marine ply.I. S. No. 3087 – 1965. Wood particle boards (Medium density)I. S. No. 848 – 1974. Specification for synthetic resin adhesives for plywood (Phenolic &Amino plastic)I. S. No. 2046 – 1969. Specification for decorative laminate.I. S. No. 8273 – 1976. Fibrous gypsum plaster boards.I. S. No. 2095 – 1964. Gypsum plaster boards.I. S. No. 2542 (part I) – 1978. Gypsum plaster concrete and products, methods of test forpart I – plaster and concrete.

Page 97: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 97

I. S. No. 8272 – 1976. Gypsum plaster for use in the manufacture of fibrous plasterboards.I. S. No. 2441 – 1963. Fixing coiling coverings code of practice for.I. S. No. 2835 – 1977. Specification for flat transparent sheet glass.I. S. No. 2395 (Part I) – 1966 2395 (Part II) – 1967Painting to concretes, masonry, plaster surfaces code of practice for part – I operation andworkmanship part II schedule.I. S. No. 3548 – 1966. Glazing in building code of practice for.I. S. No. 6278 – 1971. White washing and colour washing, code for practice for.I. S. No. 137 – 1965. Specification for ready mixed paint brushing, matt or egg shall flatfinishing, interior to Indian standards colours as required.I. S. No. 133 – 1975. Specification for ready mixed paint brushing, wooden coating, interiorto Indian standard colours.I. S. No. 129 – 1950. Specification for enamel interior (a) under coating (b) finishingI. S. No. 90 – 1950. Specification for ready mixed paint brushing gray filler for enamel foruse over primer.I. S. No. 129 – 1950. Specification for ready mixed paint brushing, finishing, interior, oilgloss, for general purposes to Indian standard colours.I. S. No. 533 – 1973. Specification for gum sprit of turpentine (oil of turpentine)I. S. No. 101 – 1964. Methods of test for ready mixed paints and enamel.I. S. No. 75 – 1973. Specification for linseed oil, and refined.I. S. No. 77 – 1976. Specification for linseed oil, boiled for paint.I. S. No. 124 (part I) – 1976. Specification for ready mixed paint brushing, finishing, semiglosses, for general purpose.I. S. No. 5884 – Specification for woolen carpets.I. S. No. 104 – 1979. Specification for ready mixed paint brushing, finishing, zinc chromeprimer.I. S. No. 5391 – 1969. Adjustable metal chairs for use of typist and operators in telephoneexchanges.I. S. No. 8756 – 1978. Ball catches for use in wooden almirahs.I. S. No. 3499 – 1976 (part II) chairs for office purposes metal revolving and ti in.I. S. No. 5416 – 1969. General purpose wooden chairs methods of test for.I. S. No. 6185 – 1971. High chairs specification and safety requirements for.I. S. No. 4116 – 1976. Joints used in wooden furniture code of practice for.I. S. No. 3845 – 1966. Joints used in wooden furniture code of practice for.I. S. No. 7070 – 1973. Shelving racks wooden (adjustable and nonadjustable type).I. S. No. 4414 – 1977. Table tops (wooden)I. S. No. 5967 – 1969. Tables, wooden, methods of test for.I. S. No. 799 – 1979. Drawer locks, cupboards and box locks.I. S. No. 7981 – (part I) – 1975. Glossary of terms relating to builders hardware – part Ilocks.I. S. No. 204 – (part I II) 1978. Tower bos ferrous metals and nonferrous metals.The various items to be used in the interior decoration work shall be of BRANDEDmanufactures of market leaders above clause is only for specifying ISI standards.

Page 98: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 98

LIST OF ISO STANDARDS (FURNITURE)

ISO 9001:2008

ISO 14001-2004 Certified.

ISO 18001-2007 Certified.

LIST OF QUALITY ASSURANCE STANDARDS (CEILING)

1. DIN 18202 for general quality management system

2. LEED & DGNB for green building product.

3. DIN EN ISO 12543

4. DIN 1249

5. EN 13964 for ceiling standard as per EN

6. EN 13501-1 building material class A2-s1, d0

Page 99: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 99

ANNEXTURE-II

LIST OF APPROVED MAKES OF MATERIALS

INTERIOR & CIVIL WORKS

S No Material Approved Brand / Make

1 Plastic Emulsion Paint a) ICI Dulux

b) Berger

c) Nerolac

d) Asian Paints

2 Float Glass a) St. Gobain

b) Modifloat

3 Chemical to be used for anti-termite a) Wood Care

4 Commercial Board, Ply, Teak Ply,Commercial Ply, Flush Doors

a) Century Sainik

b) Merino

c) Durian

d) Alpro panels

5 Gypsum Board a) LAGYP (Lafarge), India Gypsum

6 Mineral Fibre Board False Ceiling /Modular Tiles

a) Armstrong/ AMF/ Aerostone

7 Expansion Bolts / Dash Fasteners a) Hilti

8 Glazing Sealant a) GE Sealant

9 MDF a) Nuwood , Bajaj,Greenlam

10 Floor Springs / Door Closers (Normal &Concealed types)

a) Ozone / Ingersoll (Briton)/Geze

11 Resin Based Adhesive a) Fevicol/Vamicol

12 Vinyl Flooring Armstrong , LG,Gerfloor

13 Raised Access Floor Unifloor, Cani, Hyundai or Equivalent

14 White Board a) Alkon Systems / Whitemark

15 Pin-up Board a) Sitatex , Cellotaex

16 Fire Retardant Paint a) Navair

b) Viper

17 Textured Paint a) Spectrum

b) Coral

18 Feature Paint a) Asian

b) Oikos

19 Vertical/ Roller Blinds a) MAC

b) Winfab , Vista

20 SS coated Hardware a) Hettich

b) FGV

c) Dorset

Page 100: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 100

21 Laminate a) Merino

b) Greenlam

c) Century Mica

22 Vitrified Tiles a) Nitco or Kajaria

b) Somany oy Asian or Equivalent

23 Wooden Flooring a) Power Floor

b) Kronotek

c) Span

d) Floor Master

24 Aluminium Alloy Extruded Section a) Hindalco

b) Indalco

c) Nalco

d) Jindal

25 Natural Veneers a) Century

b) Greenply

c) Durian

26 Post-formed shutter storage a) Merino

b) Century

27 Plaster of Paris Shriram, JK, Aerostone

27 Ceramic Tiles 12”x12” / 16”x16” a) Nitco

b) Asian

c) Somany

28 Locks Dorset with separate keyhole ring / Golden / Kitch

29 Pivots, Handle Bars etc Dorset / Golden / Kitch

30 Fabric Protection Fabguard / Scotchguard

31 GlassWool Insulation Twiga , Lloyod

32 Cement , White Birla White, JK White

33 Piped / Ducted Services Leo, Orient. Parko, Emson, Duralite,

34 Toilet Accessories, CP Jaquar/Euronics/Gebrit/

35 Toilet Fixtures (Washbasins, WC etc) Kohler /

36 Toilet Faucets Jaquar /

37 Flush Doors Kitply/ Alpro Panels /

38 Carpet Tiles Shaw / Interface / Roya

39 PRELAMINATED PARTICLE BOARD-EXTERIOR GRADE

ASSOCIATED DÉCOR/ ACTION TESA/ SHIRDIINDUSTRIES

40 CRCA/STEEL TATA STEEL/ BHUSHAN STEEL/ ESSAR STEEL

41 HARDWARE EBCO/ HETTICH/ HAFFELE

42 FABRIC RESPONSE/ COMRADE/ COLORAYS/ COMMRAD

Page 101: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 101

APPROVED MAKES FOR ELECTRICAL WORKS

S No Material Approved Brand / Make

1 M V CABLES SKYLINE/ HAVELLS/ POLYCAB

2 M V SWITCHGEAR L&T GROUP/ SCHNEIDER /ABB

3 PVC insulated copper conductorstranded control wires of 1100 v grade

FINOLEX/ SKEYLINE/ ESC/PPPROFLEX/POLYCAB

4 CABLE GLANDS COMET/POWER ENGG

5 COPPER LUGS HEAVY DUTY DOWELLS

6 RELAYS ALSTOM/ABB/L&T

7 MEASURING METERS AUTOMATIC ELECTRIC/KAPPA/ENERCON

8 INDICATING LAMPS VAISHNO/CONCORD/SIEMENS/GE POWER

9 BREAKER CONTROL SWITCH ALSTOM/L&T/ABB/SIEMENS

10 SELECTOR SWITCH KAYCEE/L &T /SIEMENS

11 CAST RESIN CT'S & PT'S AE/AVK SCGC/KAPPA/GILBERTS& MAXWELL/

12 OVERLEAD RELAYS & CONTACTORS L & T/ SIEMENS/ABB

13 MCCB'S L & T/GROUP SCHNEIDER/ABB/SIEMENS

14 DIGITAL METERS & KWH METERS SECURE/L&T/ENERCON

15 PUSH BUTTONS L & T/SIEMENS/ABB

16 MCB’S MDS/L&T HAGGAR/SCHNEIDER-MG/SIEMENS/HAVELL

17 CABLE TRAY SLOTCO/VENUS/ NEEDO/ AMAZONE

18 TERMINAL BLOCKS ELMEX

19 RACEWAY – WITH SHEET STEEL MM ENTERPRISES/ MEM/ AMAZONE

20 M.S. CONDUITS AND ACCESSORIES BEC

21 P.V.C. CONDUITS AND ACCESSORIES BEC/ POLYPACK/ESC/KALINGA/AKG

22 SWITCHES,PLUGS,TELEPHONE/CLIPSAL

M.K. INDIA/LEGRAND/CRABTREE/NORTH WEST

23 OUTLETS ( MODULAR TYPE (MODULAR CLIP ON TYPE)

24 G.I. PIPE TATA/JINDAL

25 CFL LIGHT FIXTURES WIPRO/ PHILIPS/KESELEC/LOUISE

26 GLS LAMPS/CFL LAMPS/ TUBE LIGHT OSRAM/ PHILIPS

27 FLUORESCENT LIGHT FIXTURES WIPRO/ PHILIPS/KESELEC/THORN

28 EARTH LEAKAGE CIRCUIT HAGER/ MDS/ ABB/MERLIN GERIN

29 PANELS INDIA TECH/ ERA CONTROL /EVA ENGINERRS

30 FIRE ALARM SYSTEM MORLEY/NOVAR/EDWARDS/APPOLO

Page 102: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 102

31 ACCESS CONTROL SYSTEM ANDCOMPONENTS &CCTV CAMERA

HONEYWELL/LENEL/TYCO/SYRISHONEYWELL/ PELCO/SONY /SAMSUNG

32 DVR SAMSUNG, NEOSYST, NOVAR, EUROPLEX, AVERS

33 MONITOR SAMSUNG/ LG

LIST OF APPROVED MAKES (CEILING)

S.NO ITEM APPROVED MAKE1 Metal False Ceiling Lindner, Goldbach, Virag2 Gypsum False Ceiling India Gypsum, Lafarge, USG3 Illuminated Ceiling Lindner, Goldbach, Virag4 Glass Partition System Lindner, Goldbach, Virag5 Timber Partition System Lindner, Goldbach, Virag6 Timber Wall Cladding Lindner, Goldbach, Virag7 Glass Door( Single & Double Leaf) Lindner, Goldbach, Virag

8 Acoustic Soft Fiber Ceiling Ecophon, Permaphon, Rockphon, Virag

(All materials shall be ISI mark)

LIST OF APPROVED MAKES FOR FURNITURES

S.NO ITEM APPROVED MAKE1 Workstation Godrej, BP Ergo, Harmony Systems, Haworth2 Storage System – Compactor Godrej, BP Ergo, Harmony Systems, Haworth3 Chairs & Tables Godrej, BP Ergo, Harmony Systems, Haworth4 Sofa – 2 seater & 3 seater Godrej, BP Ergo, Harmony Systems, Haworth5 Auditorium Chairs Godrej, BP Ergo, Harmony Systems, Haworth6 Discussion tables, Center & Corner

Tables, Reception Table, CafeteriaTable

Godrej, BP Ergo, Harmony Systems, Haworth

7 Display Rack Godrej, BP Ergo, Harmony Systems, Haworth

8 Library Racks Godrej, BP Ergo, Harmony Systems, Haworth

9 Overhead storage racks Godrej, BP Ergo, Harmony Systems, Haworth

10 Casualty Room table Godrej, BP Ergo, Harmony Systems, Haworth

11 Podium Godrej, BP Ergo, Harmony Systems, Haworth

Page 103: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 103

LIST OF APPROVED MAKES OF SYSTEM INTEGRATION WORKS

S. No. Description of Work Approved Makes

I CONFERFENCE ROOM SOLUTION- Control & facilityBuilding

A DISPLAY SYSTEM

1 Full HD LED Display of 55"with Wall mount / Table mount Panasonic / Sharp/ Hitachi

2 DLP HD Projection system of 4500 Lumens, 350W, 3000:1,Standard Lens, Color Wheel, Horizontal Frequency: 15,30 - 90kHz;Vertical Scan Rate: 43 - 85 Hz; Keystone Correction: ±15°Vertical.

Delta(Vivitek) / Barco /Digital Projection

3 Motorized Lift for above projector Custom4 Motorized-electrically operated Matte White finished projection

screen of 65” x 116" [133" Diagonal] size, flame retardant andmildew with minimum viewing angle 60 degrees, Gain 1.0. Shallhave specially designed motor mounted inside the roller with noisesilencer, three wire quick reversal type, oiled for life, withautomatic thermal overload cut-out, pre-set but adjustable limitswitches, with black masking borders standard. Bottom of fabricshall be formed into a pocket holding metal rod. Case to be 21-gauge powder coated steel, hexagon in shape with flat back,complete with three position control switch in box with cover plate

Da-lite / Draper /Remaco

Relay Interface for Up-Down movement of Motorized ProjectionScreen Reputed

B SOURCE EQUIPMENTS

5 1+ 5 party HD Point to Multipoint Video Conferencing Systemconsisting of--Omni Directional Microphone--10X optical zoom Full HD Camera--PC for Presentation sharing--Inbuilt recording on Memory stick feature

Sony / Cisco

6 16 port 10/100/1000 Mbps Layer2 Giga Network Switch HP / Netgear /Cisco

7 DVD and HDD recorder features a HD Digital Tuner, 320GB HDD,1080p up scaling via HDMI and MP3 Juke Box Reputed

C AUDIO RE-INFORCEMENT SYSTEM

8 Embedded Boundary Microphones on conference table Beyerdynamic9 Digital Signal Processor with echo canceller for minimum 16 audio

inputsBi-amp

10 Feedback suppressor with built-in automatic mixer for the twomicrophone inputs should automatically adapts up to 12 dBadditional gain before feedback occurs in the acoustical situation,

Bosch (EV) /Martin Audio /Cerwin Vega

11 Multi-Channel Amplifier Bi-amp12 Speaker System Kramer / Extron /

Bosch (EV)13 Volume and audio source selector panel Biamp

Page 104: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 104

D CONTROL SYSTEM

14 Integrated Control System for presentation and co-ordinationbetween various audio-video and lighting control services through5.2" Active Matrix Display featuring VoIP Intercom, 256 MB Flash /128MB Standard SDRAM Memory, integrated battery, integratedkickstand & (1) PS3.0 Power Supply and Integrated NetLinxController with 404 MIPS Processor, 64MB RAM, 128 MB of FLASH.8 IR Ports, 8 I/O Ports, 8 Relays, and 7 RS-232 / 422 / 485 Ports

AMX / Crestron /Extron

15 Dimmer / Light Control system for Presentations Raylogic / AMX /Crestron

16 Multiformat Transmitter with receiver for 2 x Laptop and 1 x VCConnectivities. Kramer / Extron

17 HDMI Matrix switcher of minimum 6 in and 6 out or more withMax. Data Rate 2.25Gbps per graphic channel, HDCP Compatible,HDTV Compatible, HDMI Support HDMI (V.1.4 with 3D, DeepColor, x.v.Color), 3D Pass-Through, reclocks and equalizes thesignal and can route any input to any or all outputssimultaneously.

Kramer/ Extron

18 HDMI Transmitter with Receiver for Display System (55" LEDDisplay and Projector) Kramer / Extron

19 HDMI Audio De−Embedder with 1xHDMI, 1xS/PDIF, 1xTOSLINKand 1xStereo (U) outputs for Multi-media output of laptoppresentation

Kramer / Extron

E CABLES AND CONNECTORS

20 High−performance 1.5M HDMI (M) to HDMI (M) patch cord withmolded HDMI connectors at both ends and with Ethernet Support:• High Data Transfer Rate Up to 10.2Gbps.• SupportedResolutions 720p/1080i/1080p Ideal for connecting HD devices toHD/full HD plasma/LCD, PSP3, Blu−ray and HD DVD.• Deep ColorSupports 24−bit, 30−bit, 36−bit and 48−bit (RGB or YCbCr) colordepths.• Multi-Channel Audio Support - Supports audio stream forexternal decoding by AV receivers and automatic audio syncingcapabilities.• High Quality Connectors Gold−plated connectorsresist corrosion.

Kramer / Extron /Belden

21 1.5M VGA+A molded Patch cord complete with connectors Kramer / Extron /Belden

22 1.5M molded Audio Cable complete with connectors Kramer / Extron /Belden

23 Audio / Speaker cable, Twisted pair stranded 26/30 (16 AWG)copper, designed for connecting speakers and amplifiers

Kramer / Extron /Belden

24 Four pair individually aluminum−foil shielded twisted pair, cabledwith a drain conductor and overall braid−shielded -23AWG ControlCable

Kramer / Extron /Belden

25 Four pair individually aluminum−foil shielded twisted pair (S/FTP),cabled with a drain conductor and overall braid−shielded -23AWGData Cable designed for twisted pair digital transmitter − receiversets to provide optimum range and performance for 10GBase−Tapplications as defined in IEEE 802.3an and for PoE+ suitable forterminated with shielded RJ−45 connectors

Kramer / Extron /Belden

26 Shielded RJ-45 Crimp Connector for 23 AWG Cable Kramer / Extron /Belden

Page 105: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 105

27 1.5M power molded Cable complete with connectors Reputed Make

F OTHER MISCELLANEOUS ITEMS

28 19" Equipment Rack of 24U Rittal / President /Valrack / MTS /

Intellerack29 Online UPS of 3 KVA with 30 minutes back-up Libert / APC

II Admin Building

Full HD LED Display of 42" with Wall mount / Table mount for [2 xwaiting lobby + 3 x Officer's rooms}

Panasonic / Sharp/ Hitachi

III Admin - CONFERFENCE ROOM SOLUTIONA DISPLAY SYSTEM

1 Full HD LED Display of 55"with Wall mount / Table mount Panasonic / Sharp/ Hitachi

2 DLP HD Projection system of 4500 Lumens, 350W, 3000:1,Standard Lens, Color Wheel, Horizontal Frequency: 15,30 - 90kHz;Vertical Scan Rate: 43 - 85 Hz; Keystone Correction: ±15°Vertical.

Delta(Vivitek) / Barco /Digital Projection

3 Motorized Lift for above projector Custom4 Motorized-electrically operated Matte White finished projection

screen of 65" x 116" [133" Diagonal] size, flame retardant andmildew with minimum viewing angle 60 degrees, Gain 1.0. Shallhave specially designed motor mounted inside the roller with noisesilencer, three wire quick reversal type, oiled for life, withautomatic thermal overload cut-out, pre-set but adjustable limitswitches, with black masking borders standard. Bottom of fabricshall be formed into a pocket holding metal rod. Case to be 21-gauge powder coated steel, hexagon in shape with flat back,complete with three position control switch in box with cover plate

Da-lite / Draper /Remaco

Relay Interface for Up-Down movement of Motorized ProjectionScreen Reputed

B SOURCE EQUIPMENTS

5 1+ 5 party HD Point to Multipoint Video Conferencing Systemconsisting of:--Omni Directional Microphone--10X optical zoom FullHD Camera--PC for Presentation sharing--Inbuilt recording onMemory stick feature

Sony / Cisco

6 16 port 10/100/1000 Mbps Layer2 Giga Network Switch HP / Netgear /Cisco

7 DVD and HDD recorder features a HD Digital Tuner, 320GB HDD,1080p up scaling via HDMI and MP3 Juke Box Reputed

C AUDIO RE-INFORCEMENT SYSTEM

8 Embedded Boundary Microphones on conference table Beyerdynamic9 Digital Signal Processor with echo canceller for minimum 16 audio

inputsBi-amp

Page 106: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 106

10 Feedback suppressor with built-in automatic mixer for the twomicrophone inputs should automatically adapts up to 12 dBadditional gain before feedback occurs in the acoustical situation,

Bosch (EV) /Martin Audio /Cerwin Vega

11 Multi-Channel Amplifier Bi-amp12 Speaker System Kramer / Extron /

Bosch (EV)13 Volume and audio source selector panel Biamp

D CONTROL SYSTEM

14 Integrated Control System for presentation and co-ordinationbetween various audio-video and lighting control services through5.2" Active Matrix Display featuring VoIP Intercom, 256 MB Flash /128MB Standard SDRAM Memory, integrated battery, integratedkickstand & (1) PS3.0 Power Supply and Integrated NetLinxController with 404 MIPS Processor, 64MB RAM, 128 MB of FLASH.8 IR Ports, 8 I/O Ports, 8 Relays, and 7 RS-232 / 422 / 485 Ports

AMX / Crestron /Extron

15 Dimmer / Light Control system for Presentations Raylogic / AMX /Crestron

16 Multiformat Transmitter with receiver for 2 x Laptop and 1 x VCConnectivities. Kramer / Extron

17 HDMI Matrix switcher of minimum 6 in and 6 out or more withMax. Data Rate 2.25Gbps per graphic channel, HDCP Compatible,HDTV Compatible, HDMI Support HDMI (V.1.4 with 3D, DeepColor, x.v.Color), 3D Pass-Through, reclocks and equalizes thesignal and can route any input to any or all outputssimultaneously.

Kramer/ Extron

18 HDMI Transmitter with Receiver for Display System (55" LEDDisplay and Projector) Kramer / Extron

19 HDMI Audio De−Embedder with 1xHDMI, 1xS/PDIF, 1xTOSLINKand 1xStereo (U) outputs for Multi-media output of laptoppresentation

Kramer / Extron

E CABLES AND CONNECTORS

20 High−performance 1.5M HDMI (M) to HDMI (M) patch cord withmolded HDMI connectors at both ends and with Ethernet Support:• High Data Transfer Rate Up to 10.2Gbps.• SupportedResolutions 720p/1080i/1080p Ideal for connecting HD devices toHD/full HD plasma/LCD, PSP3, Blu−ray and HD DVD.• Deep ColorSupports 24−bit, 30−bit, 36−bit and 48−bit (RGB or YCbCr) colordepths.• Multi-Channel Audio Support - Supports audio stream forexternal decoding by AV receivers and automatic audio syncingcapabilities.• High Quality Connectors Gold−plated connectorsresist corrosion.

Kramer / Extron /Belden

21 1.5M VGA+A molded Patch cord complete with connectors Kramer / Extron /Belden

22 1.5M molded Audio Cable complete with connectors Kramer / Extron /Belden

23 Audio / Speaker cable, Twisted pair stranded 26/30 (16 AWG)copper, designed for connecting speakers and amplifiers

Kramer / Extron /Belden

24 Four pair individually aluminum−foil shielded twisted pair, cabledwith a drain conductor and overall braid−shielded -23AWG ControlCable

Kramer / Extron /Belden

25 Four pair individually aluminum−foil shielded twisted pair (S/FTP), Kramer / Extron /

Page 107: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 107

cabled with a drain conductor and overall braid−shielded -23AWGData Cable designed for twisted pair digital transmitter − receiversets to provide optimum range and performance for 10GBase−Tapplications as defined in IEEE 802.3an and for PoE+ suitable forterminated with shielded RJ−45 connectors

Belden

26 Shielded RJ-45 Crimp Connector for 23 AWG Cable Kramer / Extron /Belden

27 1.5M power molded Cable complete with connectors Reputed Make

F OTHER MISCELLANEOUS ITEMS

28 19" Equipment Rack of 24U Rittal / President /Valrack / MTS /

Intellerack29 Online UPS of 3 KVA with 30 minutes back-up Libert

IV Audio-Video System for 100 Seater Auditorium

A DIGITAL PODIUM CONSISTING OF: -

1 1/3" CCD imaging camera for digital podium with 1280 x 960resolution, 720p format, 12X optical zoom, capable to view assmall as 10mm and 260mm large objects, LED light source, USB &LAN connectivities, capable to switch between Camera display andPC images, complete in all respect & as per specifications.

Wolf Vision /Bosch

B PROFESSIONAL AUDIO SYSTEM CONSISTING OF: -

2 wall mount main FOH speakers loudspeaker with permanent installsingle 15" LF, single 1.25" or more HF driver with FrequencyResponse (-10 dB) 45 Hz - 20 kHz and the Sensitivity of 98 dB ormore ( 1W/1m) delivering a Max SPL 131 dB or more. Theloudspeaker should have a horizontal coverage angle of 90 degreeor better. It should have Power handling continuous.600-800Watt.The loudspeaker should have integrated bracket or min10 suspension points for permanent installation complete in allrespect & as per specifications.

Bosch (EV) /Martin Audio /Cerwin Vega

3 Wall mount main Delay speakers with Permanent install, flying,single 12" Full Range 2 Way loudspeaker. The loudspeaker shouldhave frequency range (-10dB) of 55Hz-20kHz.It should havesensitivity (1W/1m) of 99 dB delivering Max SPL of 129dB ormore. The loudspeaker should a nominal impedance of 8 ohmsand it should have with power handling pk of 1200W or more. Thespeaker must be a permanent install loudspeaker with a min of 4or more integrated suspension points complete in all respect & asper specifications.

Bosch (EV) /Martin Audio /Cerwin Vega

4 Subwoofer speaker with permanent installed, single 18" LF .Itshould have a Freq. Range (-10 dB) of 50 Hz - 600Hz Hz. It shouldhave a sensitivity of (1W/1m) 99 dB or more delivering maxcalculated SPL of 131 dB or more. The loudspeaker should have anominal impedance of 8ohm and Power Handling pk. of 4000W ormore complete in all respect & as per specifications.

Bosch (EV) /Martin Audio /Cerwin Vega

Page 108: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 108

5 Stage Monitor speaker with in-built amplifier having 12" LF ,1" ormore HF with frequency range of 55Hz - 20kHz (-10dB) or betterdelivering a max SPL 131dB SPL .It should have horizontal andvertical coverage angle of 90 degree and 50 degree or better.The loudspeaker should have inbuilt amplifier of class D deliveringa power of 1000W or more. It should have integrated monitorangle on the enclosure for use floor monitor complete in allrespect & as per specifications.

Bosch (EV) /Martin Audio /Cerwin Vega

6 Wall mount loudspeaker with dual 3.5" LF or more, single 0.75"HFdriver with Built-in LMT. It should have Frequency Response (-10dB) of 90 Hz - 20 kHz. The loudspeaker should have a sensitivity(1W/1m) of 85 dB or more delivering a Max SPL 106 dB or morewith Horizontal and Vertical coverage angle of 90 -120 degreeand 60-90 degree respectively .The loudspeaker should havepower handling pk of 300 Watt. The loudspeaker should have in-built LMT with power tap settings of 70V/100V:10W or more .Itshould have integrated mounting bracket for permanentinstallation complete in all respect & as per specifications.

Bosch (EV) /Martin Audio /Cerwin Vega

7 Class H Dual channel power amplifier with specification as belowor BETTER to suit the power requirement of proposed speakers;Max Midband Output Power:1150W @ 4 ohms,1750W @ 2 ohms,Max Bridged Output Power:3600W @ 4 ohms, FrequencyResponse:20Hz - 20 KHz, THD:<0.03%,Max inputlevel:+21dBu,Crosstalk<80dB,input impedence:20kohm,signal tonoise ratio : >110dB ,with built in protection such as AudioLimiters, Temperature, DC, HF Short Circuit, Peak Currentprotections complete in all respect & as per specifications.

Bosch (EV) /Martin Audio /Cerwin Vega

8 Dual channel power amplifier with specification as below orBETTER to suit the power requirement of proposed speakers;Max Midband Output Power:550W @ 4 ohms,600W @ 2 ohms,Max Bridged Output Power:1250W @ 4 ohms, FrequencyResponse:20Hz - 20 KHz, THD:<0.03%,Max inputlevel:+20dBu,Crosstalk<80dB,input impedence:20kohm,signal tonoise ratio : >108dB ,with built in protection such as AudioLimiters, Temperature, DC, HF Short Circuit, Peak Currentprotection complete in all respect & as per specifications.

Bosch (EV) /Martin Audio /Cerwin Vega

9 Single channel power amplifier for Control Room Speakers withspecification as below or BETTER to suit the power requirement ofproposed speakers;Rated Output Power:250W@70V/100V ,Frequency Response:70Hz- 20KHz,THD:<0.5%,Max input level:+21dBu,inputimpedence:20kohm,,with built in protection such as AudioLimiters, Temperature protection, Peak Current protectionscomplete in all respect & as per specifications.

Bosch (EV) /Martin Audio /Cerwin Vega

10 100 W volume control for Speakers at Green room and controlcomplete in all respect & as per specifications.

Bosch / Atlas /Kramer / Extron

Page 109: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 109

11 Digital Signal Processor with 2 x XLR IN, electronically balancedaudio input,6 x XLR OUT, electronically balanced audio outputwith 2 x XLR Thru out ,and 1x XLR AES/EBU IN digital input, withNominal Input Voltage:1.23V / +4 dBu, maximum inputvoltage:8.7V / +21 dBu, input impedance :10k Ohm, CMR:-80dB@1kHz,A/D &D/A conversion :24 bit sigma delta,THD+N<0.01% complete in all respect & as per specifications.

Bosch (EV) /Martin Audio /Cerwin Vega

12 10 channel Mixer with Digital Audio interface with 4 inputchannel & 4 output channels with AD/DA conversion 24-bit and;USB 2.0 PC Interface, MIDI interface, OLED display;100 Digitaleffects presets with at least 20 user preset available. 6 mono & 4stereo channels, 6 auxiliary outputs, 11 band stereo equalizer;THD (at 1kHz) <0.005%, frequency response (-3dB):20Hz to65kHz; crosstalk >85dB, CMRR (at 1kHz)>80dB, Equivalent inputnoise:-130dBu A, maximum level Mic inputs: +21dBu complete inall respect & as per specifications.

MIDAS / Dynacord

13 Handheld Wireless Mic system that has a min of 14-hour batterylife from two AA alkaline batteries. Cardiod polar pattern, Dynamicmicrophone ,frequency response 83Hz-18kHz,RF sensitivity < 1.0Uv, Image rejection>55dB,Dyanmic range >95dB and receiverhaving 30 channels possible, S/N ratio >100dB A, dynamic range>95db B, distortion <1 %,frequency band:618-634MHz,modulation:+/-40kHz complete in all respect & as perspecifications.

Bosch (EV) /Sennheiser

14 Wireless Lapel Mic system that has a min of 14-hour battery lifefrom two AA alkaline batteries. Cardiod polar pattern, Dynamicmicrophone , frequency response 83Hz-18kHz, RF sensitivity < 1.0Uv, Image rejection >55dB, Dynamic range >95dB and receiverhaving 30 channels possible, S/N ratio >100dB A, dynamic range>95db B, distortion <1 %,frequency band: 618-634MHz,modulation:+/-40kHz complete in all respect & as perspecifications.

Bosch (EV) /Sennheiser

15 Gooseneck Mic with XLR base for podium having back electretcondenser microphone element ,Hyper Cardioid polar pattern,programmable switch, frequency response 55Hz-20kHz ,sensitivity5.5mV/Pa, clipping level >130dB SPL, output impendence 200ohm complete in all respect & as per specifications.

Bosch (EV) /Sennheiser

16 feedback suppressor with built-in automatic mixer for the twomicrophone inputs should automatically adapts up to 12 dBadditional gain before feedback occurs in the acoustical situation,complete in all respect & as per specifications.

Bosch/ MartinAudio / Cerwin

Vega

C PRESENTATION SWITCHER WITH SCALER & TOUCHCONTROL SYSTEM: -

Page 110: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 110

17 Integrated Control System for presentation and co-ordinationbetween various audio-video and lighting control services through5.2" Active Matrix Display featuring VoIP Intercom, 256 MB Flash /128MB Standard SDRAM Memory, integrated battery, integratedkickstand & (1) PS3.0 Power Supply andIntegrated NetLinx Controller with 404 MIPS Processor, 64MBRAM, 128 MB of FLASH. 8 IR Ports, 8 I/O Ports, 8 Relays, and 7RS-232/422/485 Ports complete in all respect & as perspecifications.

AMX / Crestron /Extron

18 Furniture-Mountable durable, metal enclosure for Cables, AAPs,and AC Power Outlets with dimension of 6.96" W x 6.96" D (17.68cm W x 17.68 cm D) that can be mounted into a tabletop or otherflat surface with a Blank anodize finish and a single Universal typepower outlet complete in all respect & as per specifications

Extron / Kramer

19 Cable Cubby AC Universal Power Module complete in all respect &as per specifications. Extron / Kramer

20 Two-input automatic switcher HDCP compliant transmitter wallplate for sending HDMI or RGBHV video, audio, and Ethernet upto 330 feet (100 m) over a single CAT 5-type cable. The unitoffered can be remotely powered. It should be able to supportsignal with resolutions of 1920 x 1200 including 1080p/60 with thedata rates up to 6.75 Gbps, Deep Color up to 12-bit, 3D, HDlossless audio formats, and CEC complete in all respect & as perspecifications.

Extron / Kramer

21 Long Distance XTP Receiver for HDMI; HDCP compliant; able tosupport 1080p / 60 Deep Color and 1920x1200 video signals,HDMI data rates up to 6.75 Gbps with deep color, 3D and HDAudio; HDMI audio de-embedding with analog stereo and digitalS/PDIF audio outputs; local Analog audio also; bidirectional RS-232 and IR up to 330 feet (100 m) over a single CAT 5-type cable;capable of remote powering complete in all respect & as perspecifications.

Extron / Kramer

22 HDMI Matrix Switcher, should support computer-video to1920x1200, including HDTV 1080p / 60; HDMI; data rates up to6.75 Gbps, Deep Color up to 12-bit, 3D, and HD audio formats,automatic cable equalization for each input to 100 feet (30meters) at 1920 x 1200 / 8-bit color; Speed Switching for HDCP-encrypted content; Key Minder for continuously verifying HDCPcompliance; EDID Minder should automatically manage EDIDcommunication between connected devices; Automatic output re-clocking to Reshape and restore timing of HDMI signals at eachoutput, enabling transmission over long HDMI cables; InterfaceFormat Correction; capability to separate an embedded audiosignal from its corresponding video signal within the matrixswitcher, allowing the audio and video signals from one source tobe switched to different destinations; should provide +5 VDC, 250mA power on the HDMI outputs for external peripheral devicescomplete in all respect & as per specifications.

Extron / Kramer

Page 111: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 111

23 HDMI Audio De-Embedder, Supports HDCP, HDMI audio de-embedding with analog stereo and digital S/PDIF audio outputs;data rates up to 6.75 Gbps, Deep Color up to 12-bit, and 3D,Cable equalization at input; EDID Minder automatically managesEDID communication between connected devices; LED indicatorsfor HDCP confirmation, signal, Link status and Power Complete inall respect & as per specifications.

Extron / Kramer

24 Long Distance XTP Transmitter for HDMI; It should be HDCPcompliant and able to support 1080p/60 Deep Color and1920x1200 video signals, HDMI audio embedding with analogstereo audio, local Analog audio also. Ethernet, remote power,bidirectional RS-232 and IR up to 330 feet (100 m) over a singleCAT 5-type cable; HDMI data rates up to 6.75 Gbps with deepcolor, 3D and HD Audio; capable of remote powering complete inall respect & as per specifications.

Extron / Kramer

25 Long Distance XTP Scaling Receiver, Twisted pair HDCP compliantreceiver unit that scales HDMI, DVI, RGB, HD component video,and standard definition video to the optimal output resolution forthe display. It should accept video, audio, bidirectional RS-232and IR, and Ethernet up to 330 feet (100 m) over a single CAT 5-type cable with selectable output rates from 640 x 480 to 1920 x1200, including HDTV 1080p / 60; should support data rates up to6.75 Gbps, Deep Color up to 12-bit, HD lossless audio formats,and CEC also to support various HDMI audio formats and iscapable to de-embed them from HDMI in form of Analog Stereo orS/pdif digital format with audio adjustments and muting. The unitshould be controllable via USB or Rs-232 complete in all respect &as per specifications.

Extron / Kramer

26 9.7‑inch (diagonal) color touch screen or bigger LED-backlit glossywidescreen Multi‑Touch display with 1024-by-768 resolution at132 pixels per inch (ppi), support Wi-Fi (802.11a/b/g/n) andBluetooth 2.1 + EDR technology, should have at least 16GB ofstorage memory; Built in speakers for video preview complete inall respect & as per specifications.

Reputed / asrecommended by

OEM

27 Touch Panel Control Device License. OEMRecommended

D PROJECTION SYSTEM CONSISTING OF: -

28 LCD / DLP Multimedia Projector with minimum of 6500 ANSILumens, Horizontal Frequency 30-90 KHz, Vertical scan rate 50-85Hz, image size 40" - 500"; Keystone correction of Vertical:±40° , Horizontal: ±35°degree and complete in all respect withwired and wireless between PC and Projector complete in allrespect & as per specifications.

Vivitek / Barco /Digital Projection

29 Ceiling stand for Projection System complete in all respect etc asrequired complete in all respect & as per specifications. Custom Design

Page 112: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 112

30 Motorized-electrically operated Matte White finished projectionscreen of 57.5” x 92" [109" Diagonal] size, flame retardant andmildew with minimum viewing angle 60 degrees, Gain 1.0. Shallhave specially designed motor mounted inside the roller with noisesilencer, three wire quick reversal type, oiled for life, withautomatic thermal overload cut-out, pre-set but adjustable limitswitches, with black masking borders standard. Bottom of fabricshall be formed into a pocket holding metal rod. Case to be 21-gauge powder coated steel, hexagon in shape with flat back,complete with three position control switch in box with cover platecomplete in all respect & as per specifications.

Da-lite / Draper /Remaco

Relay Interface for Up-Down movement of Motorized ProjectionScreen Reputed

E CABLES & CONNECTORS: -

31 Cat6 Cable in existing media complete in all respect & as perspecifications.

Finolex / AMP /Delton

32 Control Cable in existing media complete in all respect & as perspecifications.

Finolex / Skytone /Delton

33 Speaker Cable in existing media complete in all respect & as perspecifications.

Finolex / Skytone /Delton

34 Microphone Cable in existing media complete in all respect & asper specifications.

Finolex / Skytone /Delton

35 RGBHV Cable in existing media complete in all respect & as perspecifications. Extron / Kramer

36 RG59 Video Cable in existing media complete in all respect & asper specifications.

Finolex / Skytone /Delton

37 3 core 2.5 Sq. mm copper conductor power cables in existingmedia complete in all respect & as per specifications.

Finolex / Skytone /Delton

38 XLR Socket / Connector with Suitable Accessories Neutrik39 Speaker Socket / Connector with Suitable Accessories Neutrik

40 Phono Socket / Connector with Suitable Accessories Neutrik

V Training Centre Building

1 Full HD LED Display of 42" with Wall mount / Table mount for [4 xVIP suits + 1 x Common Room + 1 x Dinning area}

Panasonic / Sharp/ Hitachi

VI CONFERFENCE ROOM SOLUTIONA DISPLAY SYSTEM

1 Full HD LED Display of 55"with Wall mount / Table mount Panasonic / Sharp/ Hitachi

2 DLP HD Projection system of 4500 Lumens, 350W, 3000:1,Standard Lens, Color Wheel, Horizontal Frequency: 15,30 - 90kHz;Vertical Scan Rate: 43 - 85 Hz; Keystone Correction: ±15°Vertical.

Delta(Vivitek) / Barco /Digital Projection

3 Motorized Lift for above projector Custom

Page 113: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 113

4 Motorized-electrically operated Matte White finished projectionscreen of 65” x 116" [133" Diagonal] size, flame retardant andmildew with minimum viewing angle 60 degrees, Gain 1.0. Shallhave specially designed motor mounted inside the roller with noisesilencer, three wire quick reversal type, oiled for life, withautomatic thermal overload cut-out, pre-set but adjustable limitswitches, with black masking borders standard. Bottom of fabricshall be formed into a pocket holding metal rod. Case to be 21-gauge powder coated steel, hexagon in shape with flat back,complete with three position control switch in box with cover plate

Da-lite / Draper /Remaco

Relay Interface for Up-Down movement of Motorized ProjectionScreen Reputed

B SOURCE EQUIPMENTS

5 1+ 5 party HD Point to Multipoint Video Conferencing Systemconsisting of:--Omni Directional Microphone--10X optical zoom Full HD Camera--PC for Presentation sharing--Inbuilt recording on Memory stick feature

Sony / Cisco

6 16 port 10/100/1000 Mbps Layer2 Giga Network Switch HP / Netgear /Cisco

7 DVD and HDD recorder features a HD Digital Tuner, 320GB HDD,1080p up scaling via HDMI and MP3 Juke Box Reputed

C AUDIO RE-INFORCEMENT SYSTEM

8 Embedded Boundary Microphones on conference table Beyerdynamic9 Digital Signal Processor with echo canceller for minimum 16 audio

inputsBi-amp

10 Feedback suppressor with built-in automatic mixer for the twomicrophone inputs should automatically adapts up to 12 dBadditional gain before feedback occurs in the acoustical situation,

Bosch (EV) /Martin Audio /Crewin Vega

11 Multi-Channel Amplifier Bi-amp12 Speaker System Kramer / Extron /

Bosch (EV)13 Volume and audio source selector panel Biamp

D CONTROL SYSTEM

14 Integrated Control System for presentation and co-ordinationbetween various audio-video and lighting control services through5.2" Active Matrix Display featuring VoIP Intercom, 256 MB Flash /128MB Standard SDRAM Memory, integrated battery, integratedkickstand & (1) PS3.0 Power Supply and Integrated NetLinxController with 404 MIPS Processor, 64MB RAM, 128 MB of FLASH.8 IR Ports, 8 I/O Ports, 8 Relays, and 7 RS-232 / 422 / 485 Ports

AMX / Crestron /Extron

15 Dimmer / Light Control system for Presentations Raylogic / AMX /Crestron

16 Multiformat Transmitter with receiver for 2 x Laptop and 1 x VCConnectivities. Kramer / Extron

Page 114: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 114

17 HDMI Matrix switcher of minimum 6 in and 6 out or more withMax. Data Rate 2.25Gbps per graphic channel, HDCP Compatible,HDTV Compatible, HDMI Support HDMI (V.1.4 with 3D, DeepColor, x.v.Color), 3D Pass-Through, reclocks and equalizes thesignal and can route any input to any or all outputssimultaneously.

Kramer/ Extron

18 HDMI Transmitter with Receiver for Display System (55" LEDDisplay and Projector) Kramer / Extron

19 HDMI Audio De−Embedder with 1xHDMI, 1xS/PDIF, 1xTOSLINKand 1xStereo (U) outputs for Multi-media output of laptoppresentation

Kramer / Extron

E CABLES AND CONNECTORS

20 High−performance 1.5M HDMI (M) to HDMI (M) patch cord withmolded HDMI connectors at both ends and with Ethernet Support:• High Data Transfer Rate Up to 10.2Gbps.• SupportedResolutions 720p/1080i/1080p Ideal for connecting HD devices toHD/full HD plasma/LCD, PSP3, Blu−ray and HD DVD.• Deep ColorSupports 24−bit, 30−bit, 36−bit and 48−bit (RGB or YCbCr) colordepths.• Multi-Channel Audio Support - Supports audio stream forexternal decoding by AV receivers and automatic audio syncingcapabilities.• High Quality Connectors Gold−plated connectorsresist corrosion.

Kramer / Extron /Belden

21 1.5M VGA+A molded Patch cord complete with connectors Kramer / Extron /Belden

22 1.5M molded Audio Cable complete with connectors Kramer / Extron /Belden

23 Audio / Speaker cable, Twisted pair stranded 26/30 (16 AWG)copper, designed for connecting speakers and amplifiers

Kramer / Extron /Belden

24 Four pair individually aluminum−foil shielded twisted pair, cabledwith a drain conductor and overall braid−shielded -23AWG ControlCable

Kramer / Extron /Belden

25 Four pair individually aluminum−foil shielded twisted pair (S/FTP),cabled with a drain conductor and overall braid−shielded -23AWGData Cable designed for twisted pair digital transmitter − receiversets to provide optimum range and performance for 10GBase−Tapplications as defined in IEEE 802.3an and for PoE+ suitable forterminated with shielded RJ−45 connectors

Kramer / Extron /Belden

26 Shielded RJ-45 Crimp Connector for 23 AWG Cable Kramer / Extron /Belden

27 1.5M power molded Cable complete with connectors Reputed Make

F OTHER MISCELLANEOUS ITEMS

28 19" Equipment Rack of 24U Rittal / President /Valrack / MTS /

Intellerack29 Online UPS of 3 KVA with 30 minutes back-up Libert / APC

VII LECTURE HALL SOLUTIONA DISPLAY SYSTEM

Page 115: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 115

1 Interactive Ultra-short-throw DLP Projection System for classroomusage, 3000 lumens of brightness with 2,500:1 contrast ratio,Native resolution 1280 x 800, Throw ratio 0.19:1, 16:10 Native,4:3, 16:9 Compatible, manually adjustable for Image Size(Diagonal) 87" to 97"

Delta(Vivitek) / Barco /Digital Projection

2 Wall mount Kit for Short throw Projection system Custom3 Interactive White-board of 103” active diagonal size suitable for

above projection system with Aspect Ratio of 16:9 Intelle-Board

4 Multiformat Transmitter with receiver for 1 x Laptop and 1 x WhiteBoard Connectivity. Extron / Kramer

5 Cables and Connectors

B AUDIO RE-INFORCEMENT SYSTEM FOR EXECUTIVETRAINING ROOM

6 Hand-held wireless microphone system Bosch (EV) /Sennheiser

7 Gooseneck Mic with XLR base for podium having back electretcondenser microphone element ,Hyper Cardioid polar pattern,programmable switch, frequency response 55Hz-20kHz ,sensitivity5.5mV/Pa, clipping level >130dB SPL, output impendence 200ohm

Bosch (EV) /Sennheiser

8 HDMI Audio De−Embedder with 1xHDMI, 1xS/PDIF, 1xTOSLINKand 1xStereo (U) outputs for Multi-media output of laptoppresentation

Kramer / Extron

9 Feedback suppressor with built-in automatic mixer for the twomicrophone inputs should automatically adapts up to 12 dBadditional gain before feedback occurs in the acoustical situation,

Bosch (EV) /Martin Audio /Cerwin Vega

10 Dual channel (Stereo) Audio Amplifier & Switcher (40 Watts perChannel) 1 Stereo (B) 1 Stereo (U)

Kramer / Extron /Bosch

11 Volume controller for two channels of balanced stereo audiosignals on XLR connectors

Kramer / Extron /Bosch

12 2−way co−axial Closed−Back Ceiling Speakers (4Ω) Closed BackCan with Woofer − 4", Tweeter − 1", Freq − 20Hz to 20kHz,Crossover Frequency 10kHz, Sensitivity 85dB., FrequencyResponse 85Hz to 20kHz., Power Rating 20W nominal, 40W Max

Kramer / Extron /Bosch

13 Cables and Connectors Kramer / Extron /Belden

VII Canteen

A DISPLAY SYSTEM

1 Full HD LED Display of 42" with Wall mount / Table mount for Panasonic / Sharp/ Hitachi

B BACKGROUND MUSIC SYSTEM FOR CANTEEN

2 Mixer Amplifier, minimum 60 W 100/70V Speaker out. Bosch3 Booster Amplifier, minimum 240 W 100/70V Speaker out. Bosch4 Handheld Wireless microphone Bosch (EV) /

Sennheiser

Page 116: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 116

5 economic flush-mounting ceiling full range loudspeaker for speechand music reproduction, Complies to Safety acc. to EN 60065Emergency acc. to BS 5839-8 / EN 60849,,Rated power 6 / 3 / 1.5/ 0.75 W, Sound pressure level at 6 W / 1 W (4 kHz, 1 m)102 dB /94 dB (SPL),Effective frequency range (-10dB) 80 Hz to 18 kHz,Opening angle at 1 kHz / 4 kHz (-6 dB) 160° / 65°

Kramer / Extron /Bosch

6 100W volume control used to adjust the level locally, Built-in 24VDC override relay, complies to Safety acc. to EN 60065 Self-extinguishing acc. to UL 94 V0 std, Frequency response 50 Hz to20 kHz (-1 dB)

Kramer / Extron /Bosch

7 Housing for Volume control Custom8 CD player, able to play MP3, WMA audio files with USB input. Philips or

equivalent9 Equipment Rack with lockable and front perforated doors. Rittal / President /

Valrack / MTS /Intellerack

10 2 Core speaker cum control wire in existing media Finolex / Skytone /Delton

11 3 core 1.5M molded power cable Finolex / Skytone /Delton

12 3 core power cable in existing media Finolex / Skytone /Delton

SYSTEM INTEGRATORS CEECO TECHNOLOGIES PVT. LTD., NEW DELHIBHARAT RADIO CENTRE, LUCKNOWPAN INTELLECOM, NEW DELHI

Page 117: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 117

ANNEXURE-III : LIST OF TENDER DRAWINGS

Page 118: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 118

CONTROL & FACILITY BUILDING

TRAINEE HOSTEL

SWITCHYARD CONTROL ROOM BUILDING

S.No. DRAWING TITLE JOB NO. DRAWING NO.

1 GROUND FLOOR(Existing Plan)

MUA-OTPC-A-01 AR/C&F/EX-01

2 FIRST FLOOR(Existing Plan)

MUA-OTPC-A-02 AR/C&F/EX-02

3 SECOND FLOOR(Existing Plan)

MUA-OTPC-A-03 AR/C&F/EX-03

4 GROUND FLOOR(Proposed Plan)

MUA-OTPC-A-04 AR/C&F/PL-01

5 FIRST FLOOR(Proposed Plan)

MUA-OTPC-A-05 AR/C&F/PL-02

6 SECOND FLOOR(Proposed Plan)

MUA-OTPC-A-06 AR/C&F/PL-03

S.No. DRAWING TITLE JOB NO. DRAWING NO.

7 GROUND FLOOR(Existing Plan)

MUA-OTPC-A-19 AR/TH/EX-01

8 FIRST FLOOR(Existing Plan)

MUA-OTPC-A-20 AR/TH/EX-02

9 GROUND FLOOR(Proposed Plan)

MUA-OTPC-A-21 AR/TH/PL-01

10 FIRST FLOOR(Proposed Plan)

MUA-OTPC-A-22 AR/TH/PL-02

S.No. DRAWING TITLE JOB NO. DRAWING NO.

11 GROUND FLOOR(Existing Plan)

MUA-OTPC-A-31 AR/SY/EX-01

12 FIRST FLOOR(Existing Plan)

MUA-OTPC-A-32 AR/SY/EX-02

13 GROUND FLOOR(Proposed Plan)

MUA-OTPC-A-33 AR/SY/PL-01

14 FIRST FLOOR(Proposed Plan)

MUA-OTPC-A-34 AR/SY/PL-02

Page 119: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 119

ADMIN BUILDING

MEDICAL CENTRE BUILDING

TRAINING CENTER BUILDING

CANTEEN BUILDING

FIRE STATION BUILDING

S.No. DRAWING TITLE JOB NO. DRAWING NO.

15 GROUND FLOOR(Existing Plan)

MUA-OTPC-A-43 AR/AD/EX-01

16 FIRST FLOOR(Existing Plan)

MUA-OTPC-A-44 AR/AD/EX-02

17 GROUND FLOOR(Proposed Plan)

MUA-OTPC-A-45 AR/AD/PL-01

18 FIRST FLOOR(Proposed Plan)

MUA-OTPC-A-46 AR/AD/PL-02

S.No. DRAWING TITLE JOB NO. DRAWING NO.

19 GROUND FLOOR(Existing Plan)

MUA-OTPC-A-55 AR/MED/EX-01

20 GROUND FLOOR(Proposed Plan)

MUA-OTPC-A-56 AR/MED/PL-01

S.No. DRAWING TITLE JOB NO. DRAWING NO.

21 GROUND FLOOR(Existing Plan)

MUA-OTPC-A-61 AR/TC/EX-01

22 FIRST FLOOR(Existing Plan)

MUA-OTPC-A-62 AR/TC/EX-02

23 GROUND FLOOR(Proposed Plan)

MUA-OTPC-A-63 AR/TC/PL-01

24 FIRST FLOOR(Proposed Plan)

MUA-OTPC-A-64 AR/TC/PL-02

S.No. DRAWING TITLE JOB NO. DRAWING NO.

25 GROUND FLOOR(Existing Plan)

MUA-OTPC-A-73 AR/CAN/EX-01

26 GROUND FLOOR(Proposed Plan)

MUA-OTPC-A-74 AR/CAN/PL-01

S.No. DRAWING TITLE JOB NO. DRAWING NO.

27 GROUND FLOOR(Existing Plan)

MUA-OTPC-A-79 AR/FS/EX-01

28 GROUND FLOOR(Proposed Plan)

MUA-OTPC-A-80 AR/FS/PL-01

Page 120: Interior Decoration & Furnishing

PLANT: 2X363.3 MW GAS BASED COMBINED CYCLE POWER PLANT

TECHNICAL SPECIFICATIONSFOR INTERIOR DECORATION & FURNISHING OF PLANT BUILDINGS Page | 120

SECURITY HOSTEL

S.No. DRAWING TITLE JOB NO. DRAWING NO.

29 GROUND FLOOR(Existing Plan)

MUA-OTPC-A-85 AR/SH/EX-01

30 FIRST FLOOR(Existing Plan)

MUA-OTPC-A-86 AR/SH/EX-02

31 SECOND FLOOR(Existing Plan)

MUA-OTPC-A-87 AR/SH/EX-03

32 SECOND FLOOR(Proposed Plan)

MUA-OTPC-A-88 AR/SH/PL-03