Inter-RPO/FLM/EPA Fire and Smoke Meeting Austin, TX Feb 9-10, 2005

38
1 Inter-RPO/FLM/EPA Fire and Smoke Meeting Austin, TX Feb 9-10, 2005 VISTAS Presentation

description

Inter-RPO/FLM/EPA Fire and Smoke Meeting Austin, TX Feb 9-10, 2005. VISTAS Presentation. Meeting Objectives. Review scientific and technical approaches to develop fire emission inventories for RH and other SIPs Identify differences in approaches among RPOs and opportunities for collaboration - PowerPoint PPT Presentation

Transcript of Inter-RPO/FLM/EPA Fire and Smoke Meeting Austin, TX Feb 9-10, 2005

Page 1: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

1

Inter-RPO/FLM/EPA Fire and Smoke Meeting

Austin, TXFeb 9-10, 2005

VISTAS Presentation

Page 2: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

2

Meeting Objectives

• Review scientific and technical approaches to develop fire emission inventories for RH and other SIPs

• Identify differences in approaches among RPOs and opportunities for collaboration

• Promote sharing of inventories for multi-RPO modeling

• Facilitate coordination with Federal Agencies (tools, policy, guidance)

Page 3: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

3

Part I – Technical Approaches

• VISTAS has developed a protocol to use in CMAQ modeling for base and future year

• Want to share VISTAS approach

• Final modeling will be at end 2005 or beginning of 2006

Page 4: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

4

2002 Emissions Inventory Review for Ag Burning, Prescribed Fires, Wildfires, and

Land Clearing• Activity Data• Temporal and Spatial Quality• QA/QC• Fuel Assignments• Fuel Loading• Daily Emission Profile• Plume Rise Approach• EI Formats Available• Modeling Issues

Page 5: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

5

State Supplied 2002 Fire Activity Data

State Agriculture Prescribed/Silviculture

Land Clearing

Wildfires

AL FL GA KY MS NC SC TN VA WV

Page 6: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

6

Federal Agency Supplied 2002 Fire Activity Data

Agency Agriculture Prescribed/ Silviculture

Land Clearing

Wildfires

USFS

FWS

NPS

BLM

BIA

Page 7: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

7

2002 VISTAS PM2.5 Emissions from Fire Sources

0

10

20

30

40

50

60

70

AL FL GA KY MS NC SC TN VA WV

State

Th

ou

san

ds

of T

on

s

Land Clearing Agri. Wildfires Prescribed

S

SS

S

S

S

S

S

SS

S

S

S S S SS

SS S S

S

Page 8: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

8

Temporal and spatial quality

• Issues:– No centralized guidelines/requirements– For fires recorded as acres burned per county

on monthly basis, it is hard to track as “point source” because there’s no lat/lon data or date of incident

• Options:– Use satellite imagery or GIS to improve

temporal/spatial distribution

Page 9: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

9

Elevated Fire Emissions(Annual Temporal Plot of CO Emissions in VISTAS 12km)

Most Emissions from VISTAS Fires Occur in Spring

Page 10: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

10

Comparison of VISTAS Rx Fire to Previously Used Temporal Profile

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Month

Fra

cti

on

of

Ac

res

Bu

rne

d

VISTAS Data - 10 States VISTAS Data - 9 States Default Profile

Page 11: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

11

Elevated Fire Emissions(Daily Spatial Plots of CO Emissions)

Page 12: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

12

Elevated Fire Emissions(Daily Spatial Plots of CO Emissions)

Page 13: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

13

Elevated Fire Emissions(Daily Vertical Layer Plots of CO Emissions)

Indicates layer in which emissions are injected Example: 250 tpd CO injected into layer 9

Page 14: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

14

QA/QC

• All emission data sets reviewed for proper format and content– Ensured appropriate structure for conversion– Verified all categories represented when expected– Reviewed for outlying data points– Removed double counting of incidents

• In cases where errors found, verified original data source and corrected or revised with appropriate value

Page 15: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

15

QA/QC (cont.)

• Emission tables and charts developed for State-to-State comparisons

• County-level maps plotted to highlight “hot spots” and empty cells

Page 16: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

16

Fuels Hierarchy• State-supplied data

– if provided, these values were always used• Federal agency-supplied data

– if provided, values were used. If federal record is redundant of state fire record, state data used.

• National Fire Danger Rating System (NFDRS) Model– The default values for the NFDRS fuel models were provided by Bruce

Bayle, USFS Region 8

• Material burned type– a NFDRS value was assigned if the material burned could be

easily matched to a NFDRS fuel model• State specific defaults calculated

– where no material burned type was provided• AP-42 values

– for fires other than wildfires or prescribed burns

Page 17: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

17

Fire Plume Rise Algorithm

• Based on data generated from the Southern High-Resolution Modeling Consortium Coupled Prescribed Fire–Air Chemistry Modeling Framework [SHRMC-4S]

– Daysmoke module of Framework– Dr. Gary Achtemeier & Staff

• USDA Forest Service, Athens, GA• Presentation made to VISTAS on Sept. 1

Page 18: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

18

Daysmoke as a Smoke Injector for CMAQ

• Plume time scale – plume changes during course of burn

• Vertical distribution– how high smoke goes, – which levels emissions are distributed, – how much smoke distributed at each level and

when

Source: Achtemeier presentation to VISTAS; 1 September 2004

Page 19: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

19

Normalized vertical distribution of smoke particles estimated using Daysmoke (red) and Briggs scheme (green). (Average over all fires in FL on 3/6/2002)

Source: Achtemeier presentation to VISTAS; 1 September 2004

Page 20: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

20

Implementation of Profile

• “Average” profile developed based on single sounding in Florida during 2002 fire season

• Category 1 or 2 fires (<100 acres)– No change to plume rise calculation

• Category 3 fires “capped” at Daysmoke upper bound– Moved from 3,528 to 1,029 m (layer 16 to 11)

• Category 4 and 5 plumes reduced by same percentage from Briggs estimated height

– Cat 4 from 5,095 to 1,488 m (layer 16 to 13)– Cat 5 from 6,351 to 1,854 m (layer 17 to 14)

Page 21: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

21

EI Formats (Fires)

• Annual 2002 NIF 3.0 files– Includes agricultural, prescribed, land clearing and

wildfire data

• Modeling files generated using more specific raw data– Includes acres, dates, and locations of fire activity– Generated elevated fire file for sources with

appropriate data elements– Non-elevated sources retained in county-level area

source file

Page 22: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

22

Modeling Issues

• If fires did not meet requirement of elevated development (e.g., lat/lon, date)

– Aggregated into area source file for low level modeling

– Centroid and temporal profiles assigned

• Elevated fires converted to day specific inputs and processed as point sources

Page 23: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

23

Modeling Issues (cont.)

• Township/Range/District Data – T/R/S data or models not readily available for

VISTAS domain– Project sponsored to develop T/R/S centoids

for AL/FL for purposes of spatially distributing fire activity provided on T/R/S level

– Resulted in greatly improved fire siting

Page 24: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

24

Part II – Typical Year, Baseline and 2018 Projection

Page 25: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

25

VISTAS Fire Emissions

• 2018 fire emissions based on “typical year” fire acreage – Acreage estimates collected from States and federal agencies

for recent time periods representative of “typical” conditions or readily available

– “Typical” based on a minimum of five years of data where possible

– State or county level of aggregation for each fire type

• These data were then used to “normalize” the actual 2002 base year inventory to “typical” conditions– Wildfire acreage: 7 VISTAS States – Prescribed fire acreage: 6 VISTAS States– Average of State data used for non-reporting areas

• North and South State tiers

Page 26: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

26

VISTAS “Typical” Fire Emissions

• High/Low 5% dropped in normalization

• Only change in acres burned / emissions

• Spatial and temporal distribution retained– Prevented artificial change in haze/visibility

attributed to unknown fire (particularly wildfire) activity

Page 27: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

27

Prescribed and Wildfires Acres Burned (Actual vs. Typical)

0

200,000

400,000

600,000

800,000

1,000,000

1,200,000

1,400,000

AL FL GA KY MS NC SC TN WV AL FL GA KY MS NC SC TN VA WV

Prescribed Wildfi re

2002 Actual Acres

Typical AcresCalculation

Page 28: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

28

Part III – Mexican and Canadian Fire Activity

Page 29: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

29

Canadian/Mexican Emissions

• Modeled as low level only; no elevated fire

• Data Sources– Canadian Criteria Air Contaminants (CAC) – Big Bend National Park Regional Aerosol and

Visibility Observational (BRAVO)

Page 30: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

30

Part IV -- Preliminary Model Results and Haze Attribution

• Importance of fires vs SO2– SO2 is driving factor for extinction and poor

visibility– EC contribution is low compared to

anthropogenic SO2

• Fires don’t dominate 20% worst days

Page 31: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

31

CM

Soil

Organics

EC

NH4NO3

(NH4)2SO4

Rayleigh

Light Extinction on 20% Poorest Visibility Days - IMPROVE 2000 - 2002

0

50

100

150

200

250

Cad

iz, K

Y

Sain

t Mar

ks, F

L

Extin

ctio

n (M

m-1

)

Dol

ly S

ods,

WV

Shen

ando

ah, V

A

Jam

es R

vier

Fac

e, V

A

Mam

mot

h C

ave,

KY

Sips

ey, A

L

Gre

at S

mok

y M

tns,

TN

Linv

ille

Gor

ge, N

C

Swan

Qua

rter

, NC

Cap

e R

omai

n, S

C

Oke

feno

kee,

GA

Cha

ssah

owitz

ka, F

L

Ever

glad

es, F

L

Shin

ing

Roc

k, N

C

Page 32: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

32

0

10

20

30

40

50

60

Extin

ctio

n (M

m-1

)

Cad

iz, K

Y

Sain

t Mar

ks, F

L

Dol

ly S

ods,

WV

Shen

ando

ah, V

A

Jam

es R

vier

Fac

e, V

A

Mam

mot

h C

ave,

KY

Sips

ey, A

L

Gre

at S

mok

y M

tns,

TN

Linv

ille

Gor

ge, N

C

Swan

Qua

rter

, NC

Cap

e R

omai

n, S

C

Oke

feno

kee,

GA

Cha

ssah

owitz

ka, F

L

Ever

glad

es, F

L

Shin

ing

Roc

k, N

C

CM

Soil

Organics

EC

NH4NO3

(NH4)2SO4

Rayleigh

Light Extinction on 20% Best Visibility Days - IMPROVE 2000 - 2002

Page 33: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

33

0.00

4.00

8.00

12.00

Avg

. Con

c. (µ

g/m

3)

ECNO3OMSO4

Average PM2.5 Components for Key Visibility Bins - Great Smoky Mtns., TN

Class 1 Class 5Class 4 Class 2 Class 3

(Days ranked in bins and classes from clearest to haziest days)

(20% clearest days) (20% haziest days)(51-80%)(21-50%)

Page 34: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

34

0.00

4.00

8.00

12.00

Avg

. Con

c. (µ

g/m

3)

ECNO3OMSO4

0.00

4.00

8.00

12.00

Avg

. Con

c. (µ

g/m

3)

Class 1 Class 5Class 4 Class 2 Class 3 (20% clearest days) (20% haziest days)(51-80%)(21-50%)

Class 1 Class 5Class 4 Class 2 Class 3

Average PM2.5 Components for Key Visibility Bins - a) Shining Rock, NC b) Cape Romain, SC

b)

a)

Page 35: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

35

Okefenokee (GA) – 4 daysWeighted Bext Response at Site to Reductions in

OTB Emissions: Worst 20%

-50.0

-40.0

-30.0

-20.0

-10.0

0.0

10.0

OTB-TYP

OTW-O

TBASO2

ANOXANH3

ASO2NOXNH3

AMVOC

ABVOC

APRIC

B

ext (

m-1

)

CM

SOIL

EC

OC

NO3

NH4*

SO4

30% reduction from 2018 OTBChange

2002

Typ

to 2

018

OTB

Change

2018

OTB

to 2

018

OTW

Need 45 mM-1 by 2018; model predicts~40 from OTB and ~20 from OTW

Page 36: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

36

Part V – Federal Guidance

Page 37: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

37

Federal Guidance Needed• Existing Policies – Don’t have Smoke Mgt Plans in SE?• Fire Tracking• Smoke Management Programs Required – Need to coordinate with

FS on planned prescribed burning plan for future years (2018); VISTAS will model 2018 with and without prescribed assumptions and based on the results could make recommendations

• VISTAS might not benefit in the short term, but hope to shed some light based on modeling results on accelerated schedule

• EPA requirements?• Voluntary Smoke Management Programs – who has jurisdiction?

State Dept of Ag/Forestry?• Goals & Caps• Land Clearing Burns/Open Burns

Page 38: Inter-RPO/FLM/EPA  Fire and Smoke Meeting  Austin, TX Feb 9-10, 2005

38

Policy Issues and Needs

• Legislative Deadlines – End of 2005

• RPO Schedules for Control Options

• Criteria for Implementation

• State/Tribe Role

• Solutions