Company Overview
Excellence in Providing Custom Solutions &
Achievement of Customer Satisfaction
IntelliPower Early History
• Founded in 1988 in California – Privately held
• First Single Phase UPS designed with the Intelligent Digital Control
• Influenced the company name - IntelliPower, Inc. for intelligent power
• Power Conversion Products - Double Conversion On Line Topology
• Started building private label On Line UPS for OEMs such as Deltec Corp.
• Early Military Applications - Rugged, Global Input & custom variations for: • F-22 Fighter ground support > 14 Years
• Predator UAV ground support > 12 Years • US Coast Guard > 18 Years
• Added military systems for Ft. Gordon & other bases
2
MILITARY & FEDERAL GOVT • Deployable Communications/Deployable Power
• UAV Programs • Navy Shipboard – Carriers, Destroyers, & Submarines
• C4 ISR • Missile Defense
INDUSTRIAL • Severe Environmental Requirements
• Oil and Gas Exploration • Satellite Communications Systems
• Industrial Controls • Alternative Energy
• Transportation - Traffic Signals, Toll Roads, etc. COMMERCIAL - Mission Critical
• Data Center/Server Rooms • Communications Systems
• Medical Measurement Instruments • Global & Mission Critical Applications
3
Market Segments/Strategic Focus
Typical Environments & Functional Requirements
Environmental Requirements • Extreme High and Low Temperatures (-40c to
+70c) • Mil-Std’s- 461, 810f, 901D, 464, 1399, 1275D,
167 • High Shock & Vibration • Dust and Dirt Environments • Outdoor Applications- Rain, Snow and Blowing
Sand/Dirt • Poor Power Quality from Generators or Power
Source
Functional Requirements • Sealed Weatherproof UPS • Galvanic Isolation • Global AC Inputs/Outputs • Multiple Voltages and Frequencies • Single and 3-Phase Inputs • DC Voltage Inputs/Outputs • Extended Battery Runtimes • Lithium Iron Phosphate Batteries
4
Products
• UPS • AC & DC Inputs and Outputs
• Power Conditioners • Inverters
• 12VDC-270VDC Input • 110, 115, 120, 220, 230 and 240VAC Output
• Frequency Converters • 45Hz-450Hz
• Power Converters • AC-DC/DC-AC
• PDU’s • Internal and External
• Transit Case Based Systems
5
• Double Conversion On Line, uProcessor & DSP Based Technology
• Internally Developed Technology - Can support any features needed
• Flexible structure, common boards, & programmable product mix
• Full range of functionality - ratings of 300VA to 6000VA
• Global AC Input, DC Input, AC & DC Output, Freq. Conv., Isolation
• Customized Configurations/Functions to meet exact customer requirements including controls, PDUs & communications features
• Optional Enclosures & special packaging to meet size & weight, as well as functionality for any requirements
Bright-UPS Characteristics
6
IntelliPower Power Solution Benefits
7
• Provides Peace of Mind Offering Optimum Solutions
• Internally Developed Advanced Technology (22 years)
• Not repackaged commercial UPS made in China
• Intelligent/Bright UPS digital controlled power conversion
• Unmatched flexibility to provide configurable solutions
• Proven Reliability with 22+ years in the field
• Track Record of customer satisfaction & loyalty
• Consistent Responsive Quality Service & Support
• Totally Made In USA – ISO 9001:2008 Certified
8
IntelliPower Configuration Worksheet & Website Configuration Form
9
Why IntelliPower vs. Others
IntelliPower • UPS circuitry & firmware designed fully by IntelliPower for over 23 years • For Military use & Industrial applications • Full control over all circuit design & embedded firmware technology in UPS • Can support any user customized requirements & support MIL-STDs via design
Others • Are using Commercial UPS boards not designed for military and Industrial use • Are repackaging commercial boards in rugged enclosure • Do not have access to technology of UPS boards made by other companies, UPS boards usually designed & made in China • No ability to modify circuitry or embedded firmware in UPS to meet many customer requirements
10
Typical Military Products
Military Customers
• All Branches of DoD, GD C4S, GD-AIS, GD Satcom, Rockwell Collins, Northrop Grumman, Lockheed Martin, SAIC, Telecom Systems, DRS, Raytheon, Dell Federal, L-3, Cubic, BAE, GTSI, ARINC, Boeing, ND Satcom, Marshall Com, Textron AAI, Segovia Systems, ITT , UK Royal Navy, German Navy, Dutch Navy, Italian Navy, Japanese Navy and Singapore Navy
• April 2010 received Industry Partner Award for Excellence from Army & General Dynamics
11
12
Army and Marine Programs
LMCO – Owego Power Converter/Conditioner • LAV 2 Amphibious Military Vehicle for Marines • 24VDC Input & 120VAC, 60Hz Output • MIL-STDs 1275D for military vehicles
LMCO - Virginia - Power & Frequency Converter • For Army Ft Eustis & Others • 2000VA, 1500W Rack Mount • Global 120/230VAC, 50/60Hz Input • 120VAC, 60Hz Output • No battery
Army and Marine Programs
13
SWAN and WPPL Program for Army and Marines • Global AutoSelect 120/240 VAC Input UPS • 3000VA, 2100W Power Rating • Internal Hot Swap Battery Drawer • 6 Inverter Outputs • 2 Isolated Non-Inverter Outputs • High Temp – 50c • EBP with two Hot Swap Battery Drawers
Raytheon – Ground Based Operational Surveillance System-(GBOSS) • 1100VA, 740W • 115VAC or 230VAC Input and 120VAC Output • Hot Swap Battery Drawer • High Temp – 50c • 2U, Rack 3.5”H x 17”W x 18”D
Army and Marine Corps Programs
14
US Marine Corps Tactical Data Network-Data Distribution System-Modular (TDN-DDS-M) • Global 120/230VAC, 50/60Hz Input UPS – • 120VAC, 60 Hz Output • Hot Swap batteries – 15 minute run time for 500W • Impressive Functionality in Compact (in 1U chassis) • Digital Technology – On Line Double Conversion • Isolated with Input Power Factor Correction • Rugged to meet 810F. Also 461E CE102, FCC Cl A • SNMP communications feature included • DDS-M Marines Program - GDC4S • Contract for Quantity 5000 units (so far) • After extensive field qualification testing
15
Army and Marine Corps Programs
GDC4S Warfighter Information Network-Tactical (WIN-T) UPS • 3000VA, 2100W Isolated UPS 1 • 20VAC, 45/45Hz Input & 120VAC, 60Hz Output • High Temp – 20F Rugged 110F • SNMP Communications • Hot Swap Battery • UPS: 3U- 5.25” x 17” W x 20” D • MIL-STDs
Army and Marine Corps Programs
16
GD SATCOM US Army Truck Mount • 5000VA, 4000W Isolated UPS • 230VAC, 50/60Hz Input & 230VAC, 60Hz Output • High Temp - 50C Rugged 810F • SNMP Communications • External Battery 15 minute for load of 4000W • UPS: 4U- 23”D EBP: 3U- 23”D • MIL-STDs
GDC4S ARMY TAC HUB • 3000VA, 2100W, Isolated • Global 120/230VAC Input – 120VAC, 60Hz Output • Cold Start, Remote Control, SNMP Communications • High Temp - 50C Rugged 810F • 3U-22”D Enclosure
17
Navy Projects NGC SYKESVILLE-NEWPORT NEWS UPS SYSTEMS
Common UPS For USS Gerald R. Ford Aircraft Carrier • 3000VA, 2100W Isolated for shipboard • Alt. A & B 115VAC, 50/60Hz Inputs-AutoSelect • 115VAC, 60Hz Output • Extreme Temp 60C • EBP with military batteries rated for 80C • Short Enclosures 17”D • UPS 3U & EBP 2U • SNMP Communications • Extensive testing protocol - Lab View
18
Navy Programs
LMCO-Fort Worth F35 JSF (UK Royal Navy) • Power Rating: 2KVA, 1.8KW Isolated Double Conversion On Line • Input: 220-230VAC, 45-450Hz…………..Output: 230VAC, 60Hz • Enclosure: 3U-17”D • MIL STDS: 461E, 1399, 810F
NSWC – SHIPBOARD UPS • 2000VA, 1500W Isolated for Shipboard • 115VAC Input & Output • High Temp - 50C • Modular UPS, Battery & Isolation Transformer • Free Standing Modular Enclosure
19
NGC Charlottesville Navy Shipboard UPS • 3000VA, 2100W Isolated • Global 115/230VAC, 50/60Hz Input • 115VAC, 60Hz Output • Hot Swap Battery Drawer • Navy MIL-STDs
Navy Projects
US Navy NAVAIR (NGC & BAE) • Fire Scout VTUAV • 2KVA, 1.5KW 2U Rack Enclosure • 120VAC Input/Output • Isolated - Shipboard Delta Source • Six Cir Mil output receptacles • 50C Temp Rated & MIL-STDs • Convertible for land-based racks
Navy Projects
20
Northrop Grumman Sperry Marine Guidance Control UPS for Littoral Combat Ship (LCS) • IPI Supplied complete wired 901D Rack System (2 Prototypes) • US Navy has released additional ships to be built
3KVA, 2.1KW Global 120/240VAC Input UPS 120VAC, 60Hz output
• Hot swap battery drawer in UPS enclosure • UPS Enclosure: 3U-25”D • Two more hot swap battery drawers in EBP • EBP Enclosure: 3U-25”D • Intelligent Global Isolated Input Maintenance Bypass (IGMB) • IGMB Enclosure: 3U-15”D • Cable management arms used • High Temperature Rugged Design • All Navy MIL-STDs-461E, 1399, 810F, 901D • Extensive documentation provided • Full Program Management by IntelliPower
21 21
Navy Projects
NAVY SEWIP Program (Surface Electronic Warfare Improvement Program) • 3KVA & 6KVA Navy Shipboard UPS’s • Built in PDU • 10 Computer Controlled Outlets • 400Hz & 60Hz Inputs • Multi Function Controls • Battle Short - Remote Controlled • FULL MIL-STDs Compliant
Shipboard UPS & Multi-Control System Replaceable LRU’s • 5.33KVA, 4KW, On-line Isolated • 115VAC, 60Hz Input UPS • 120VAC, 60Hz Output • Hot Swap Batteries • SNMP Ethernet Control
22
Navy Projects
Raytheon Photon Research Navy UPS • 2000VA, 1400W Isolated • 115VAC Input & Output • 15 minute battery run time with 1000W load • High Temp - 50C • 3U-24”D Enclosure • Terminal Strip Power Connections
DRS Power & Control Div – DDG-51 Destroyer • 1500VA, 1100W Isolated for Shipboard • 115VAC Input & Output • 2U External Battery Pack + Internal Battery • Approx 36 minute run time w/load of 950W • SNMP & Special controls included • Enclosure: 3U, 5.25”H x 16.89”W x 20”D Alum • Navy MIL-STDs
23
Navy NSWC Shipboard UPS For LCS • Sealed UPS to Meet IP 65+ for Rain & Dust • All Electronics are completely sealed • Air Flow across top - front to rear • Across externalized flow-through heat sinks • Sealed from internal electronics • 1100VA, 750W to 3000VA, 2100W Power Ratings • Input to Output Isolated • 115VAC, 50/60Hz Input • 120VAC, 60Hz Output or • 24VDC Output • Sealed UPS Module: 2U-23”D • EBP Battery Module: 2U- 23”D
Navy Projects
24
Italian Navy UPS Systems • 800VA, 560W Isolated • 115VAC Input & Output • 19 minute battery run time for 500W • High Temp - 50C • 2U-18”D Enclosure • Battle-short remote control
Navy Programs
Rockwell Collins Germany- Navy • Extreme Temp-65C • Global 115/230VAC In-115VAC out • Isolated for Delta Shipboard • 2U-15” Deep- Very Compact • Hot Swap Mil type batteries (80C) • Terminal strip power connections • RS232 data port • Relay control features
25
Singapore Navy UPS System • 3KVA, 2.1KW Rating in 3U Enclosure • 230VAC Input & Output, 50/60Hz • 8 Internal Large 12V10.AH Batteries • UPS: 3U, 5.25”Hx17”Wx26”D • EBP: 2U, 3.5”Hx17”Wx 24”D • 10 minute run time for 2100W • Navy MIL STDS • Environmental Testing by IntelliPower • Test Report attached
Navy Projects
26
Air Force and Special Forces Deployable UPS • Global AutoSelect 120/240 VAC Input • Outputs: Selectable 120, or 115 VAC, 50 or 60Hz • Galvanic Isolation • Rugged LCD Control/Display Panel • 4 Inverter Outputs • 2 Isolated Non-Inverter Outputs • High Temp-50C
US Air Force Programs
Air Force Programs
EC-130 Compass Call Aircraft
• 3-Phase 400Hz Input • 28Vdc output • 3kVA/2.5kW • LCD Display • Variable Speed Fans • Galvanic Isolation • Power Factor Correction • Mil Std’s 810f, 464, 461f
27
28
Industrial Applications
29
Industrial Customers
Oil Rig Field Truck Application
30
Ruggedized Global Input UPS • Rugged Uninterruptible Power System (UPS) • Hot Swap Batteries • Compact & Modular • On Line Double-Conversion Technology • Isolated with Input PFC • Global Input Voltage & Frequency • 120VAC & 24VDC Output Voltages • Military & NEMA Connectors
Oil field Applications
31
Extreme High Temperature UPS • IntelliPower Bright UPS 1500VA, 1150W • Input Voltage: 120Vac (-25% to +15%) • Input Frequency: 50/60Hz • Galvanic Isolation • Rated for an operating temp of -65C to +80C • Output Voltage: 120VAC+/- 2% • SNMP Ethernet port • UPS Operating: -22°F to 149°F (-30°C to 65°C)
Toll Road Outside Cabinet Application
32
Toll Roads • Rating: 1500VA, 1200W • Input AC Voltage: 120VAC, (-25% to +15%, without needing battery) • Input Frequency: 50/60Hz (47 to 63Hz) • PFC Feature: Input Power Factor Correction • Output Voltage: 120VAC, ±3% • Output Frequency: 50/60Hz • Temperature: -10C to +55C Operating
Schlumberger Oilfield AC & DC Output Application
AC & DC UPS System • 500VA, 350W • Input AC Voltage:120VAC • (-25% to +15%, without needing battery) • 50/60Hz (47 to 63Hz) • Input Power Factor Correction • Output Voltage: AC-120VAC, ±3% • DC- 13.5VDC with currents up to 11.8 A.(160W) • Regulation +/- 0.5%, ripple 100mV peak to peak • 50/60Hz, frequency follower • 0C to +50C Operating
33
34
Sandridge High Temp Rugged UPS
Sandridge Land Rig UPS System • 1500VA, 1250W • Input AC Voltage: 120VAC • 50/60Hz (47 to 63Hz) • Input Galvanic Isolation • 12 minutes with 1050W load • Operating Temp -10c – 60C (140F) • 3U, 5.25” D x 17”H x 20” W
Waste Water Treatment
35
City of Aurora-Pump Stations • 1500VA/1050W • Low Temp operation down to -20c • Outdoor Cabinet • Custom Ethernet Communications • 120VAC In/Out 60Hz.
36
NOV High Temp Rugged UPS
NOV Data Logging UPS System • 1100VA, 750W • Input AC Voltage: 120VAC • 45/450Hz (47 to 63Hz) • Galvanic Isolation • Operating Temp -0C – 55C • 3U, 5.25” D x 17”H x 17” W
37
Halliburton High Temp Rugged UPS
Halliburton Oil Field UPS System • 3000VA, 2100W • Input AC Voltage: 120VAC • 40/650Hz (47 to 63Hz) • Galvanic Isolation • 6 minutes with 1800W load • Front Panel Hot Swap Battery • Operating Temp -10c – 50C • 3U, 5.25” D x 19”H x 20” W
Thank You!
QUALITY POLICY
IntelliPower is committed to customer satisfaction by delivering power system
solutions and services that meet or exceed customer requirements through
design innovation and continuous improvement.
38