Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD,...

12
©2012 All rights reserved Rev. A / May 2012 Intelivalve® Solenoid Pinch Valve Installation and Operation Manual Manufacturer: Acro Associates, Inc. 1990A Olivera Road Concord, CA 94520 USA Phone: +1 (925) 6768828 Fax: +1 (925) 6808113 Email: [email protected] Internet: www.acroassociates.com Models Covered: 2100HAB*(or SS, WD, and BD)Vxxx (xxx means all numbers assigned) 2200HABVxxx 2300HABVxxx 2400HABVxxx *AB = Aluminum Body SS = Stainless Steel Body WD = White Delrin Body BD = Black Delrin Body

Transcript of Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD,...

Page 1: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

 

 

Intelivalve® Solenoid Pinch Valve  

Installation and Operation Manual 

 

 

Manufacturer:   Acro Associates, Inc. 

    1990‐A Olivera Road 

    Concord, CA 94520 

USA 

 

Phone:  +1 (925) 676‐8828 

Fax:   +1 (925) 680‐8113 

 

Email: [email protected] 

Internet: www.acroassociates.com 

 

 

Models Covered:  2100‐H‐AB*(or SS, WD, and BD)‐Vxxx  (xxx means all numbers assigned) 

2200‐H‐AB‐Vxxx 

      2300‐H‐AB‐Vxxx 

2400‐H‐AB‐Vxxx 

*AB = Aluminum Body 

  SS = Stainless Steel Body 

  WD = White Delrin Body 

  BD = Black Delrin Body 

 

Page 2: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

Contents 

 

1.1 General Overview ………………………………………………………………………………….  page 

1.2 Symbols …………………………………………………………………………………………………. page 

1.3 Safety …………………………………………………………………………………………………….. page 

1.4 Warranty ……………………………………………………………………………………………….. page 

1.5 Description of Components ……………………………………………………………………  page 

1.6 Intended Use …………………………………………………………………………………………. page 

1.7 Unpacking and Installation …………………………………………………………………….. page 

1.8 Operation ………………………………………………………………………………………………. page 

1.9 Cleaning and Maintenance …………………………………………………………………….. page 

1.10 Troubleshooting …………………………………………………………………………………….. page   

Page 3: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

1.1 General Overview 

Thank you for choosing Acro Associates, Inc. This installation and operation manual contains 

needed information to safely install, operate, maintain and troubleshoot the Intelivalve Solenoid 

Pinch Valve product line. Users should read and understand this manual in its entirety before 

beginning installation and operation. Please keep it available as a reference guide to ensure 

proper use. If lost, additional copies may be requested by contacting us through phone or email. 

 

1.2 Symbols 

The following symbols are used to alert, warn or provide notice of mechanical or electrical 

hazards associated with use of the Intelivalve Solenoid Pinch Valve product.  

 

 

Warning!  

This symbol warns of the potential for possible general injury or damage. 

 

Warning! Finger Crushing or Pinching Hazard!  

This symbol warns of the potential for possible finger injury. 

 

Warning! Electrical Shock! 

This symbol warns of the potential for possible electrical shock.  

 

Page 4: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

1.3 Safety and Compliances 

The Intelivalve Solenoid Pinch Valve product complies with applicable FCC, RoHS and CE safety 

regulations. Each unit and supporting components are assembled and tested to meet 

manufacturer specifications under a certified ISO 9001:2008 quality management system.  

 

Warning!  

Incorrect installation and operation of this product can result in injury to 

the user. User is responsible for legal compliance with following 

manufacturer installation and operation guidelines.  

 

Warning! Finger Crushing or Pinching Hazard!  

Improper operation of this product can result in finger injury to the user. 

User is responsible for legal compliance with following operation 

guidelines to avoid injury. 

 

Warning! Electrical Shock! 

Improper operation of this product can result in electical injury to the user. 

User is responsible for legal compliance with following operation 

guidelines to avoid injury. 

The Intelivalve Solenoid Pinch Valve, Acrosense FCP‐A controller and cable set comply with the 

following directives: 

RoHS 

US FCC Part 15B – Emissions 

EN 61326‐1 – Emissions and Immunity 

EN 61000‐4 ‐ Immunity 

CE 61010 ‐ Safety 

Upon initial inspection of received goods, if visible damage is seen the user is responsible for 

immediately alerting the manufacturer and not proceeding with installation.  

1.4 Warranty 

The Intelivalve Solenoid Pinch Valve product is warranted for a period of two (2) years or 2 

million total cycles, whichever comes first from the date of manufacture. Full legal warranty 

information is posted and can be found on Acro Associates website at www.acroassociates.com.  

1.5 Description of Components 

Page 5: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

The following components are shipped with each Intelivalve Solenoid Pinch Valve product. 

1‐Intelivalve Solenoid Pinch Valve 

 

 

1‐Set of Cables comprised of: 

1‐Power Cable – see diagram below 

1‐Valve to Board Cable – see diagram below 

1‐Data Communications Cable – see diagram below 

 

1‐Acrosense® FCP‐A  Controller Board 

Data Communications 

Power Cable

Valve to Board Cable

Page 6: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

 

 

1.6 Intended Use 

Use of the Intelivalve Solenoid Pinch Valve products other than the intended use stated below 

can result in protection impairment, injury to the user and is strictly prohibited.   

The Intelivalve Solenoid Pinch Valve product is used to pinch, or seal off flexible tubing within 

manufacturer conditions and specifications. The product is a set of components that are 

designed and embedded into systems or equipment where fluidic control and management is 

required. Each Intelivalve pinch valve model is specified for operation with different size tubing 

ranges. Each pinch valve is designed for 2‐way operation being fully open, or closed. In a closed 

state, power is not needed. To achieve an open state power is supplied to the pinch valve. Each 

pinch valve is designed for panel mounting where the top head portion is exposed for user 

interaction. Portions below the panel mount, along with cables and electronics are meant to be 

embedded within equipment or systems where physical user access is limited.  

The Acrosense FCP‐A electronic controller board is designed for powering and operation of up to 

two (2) Intelivalve Solenoid Pinch Valves. The cable set provided provides power and data 

communications between the electronic controller board and either one (1) or two (2) pinch 

valves.  

The combination of Intelivalve Pinch Valve with the Acrosense FCP‐A controller board and cable 

set enables several technological features to be performed including; adaptive pulse and hold 

power management (PWM), valve open and closed state sensing, presence or non‐presence of 

loaded tubing, electronic noise dampening, and life cycle usage and diagnostic failure feedback.    

Any use other than that described herein, or design modification of manufacturer’s product 

without expressed written authorization is strictly prohibited. User acknowledges and assumes 

all liabilities outside manufacturer’s intended use.  

Page 7: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

1.7 Unpacking and Installation 

Intelivalve Solenoid Pinch Valves are packaged in either foam fitting molds, or bubble wrap and 

placed inside appropriately sized cardboard boxes. Boxes are branded and labeled with 

company and packaged product information.  

Acrosense FCP‐A electronic controller boards and cable sets are packaged in electrostatic plastic 

bags, and then placed into foam fitted molds which are then enclosed in cardboard boxing. 

Boxes are branded and labeled with company information and packaged product information. 

Intelivalve Solenoid Pinch Valves may be carefully removed from their packaging and placed on 

a leveled surface for installation.  

Acrosense FCP‐A boards and cable sets should be removed and handled by the user using 

hooked up to an electrostatic grounding cable or station. It is recommended that the boards be 

securely mounted in an enclosure to protect from dust, moisture and physical contact. 

 

  FCP‐A mounted in an Enclosure     Use of Grounding Strap 

 

Installation of either the Intelivalve Solenoid Pinch Valve or the Acrosense FCP‐A board may be 

done in a horizontal or vertical axis plane. Pinch valves should be aligned and mounted into a 

electrically grounded panel. Panel mounting screws supplied by the user should then be used to 

secure the pinch valve and compress the mounting seal into a permanent fixed position for 

operation.   

Page 8: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

 

         Valves mounted – Front of Panel    Valves mounted – Rear of Panel 

 

Exposure to any direct fluids or vapors should be strictly avoided. At no point are any of the 

Intelivalve or its supporting components designed to be submerged into any fluid whatsoever.  

Tube loading must be done with caution.  The valve is to be actuated electronically to open.  

With hands at a safe distance apart hold tubing firmly and position in front and above tube slot.  

With valve open move tubing above tube entry slot and pull down into valve head making sure 

to keep fingers free of pinch area.  Once tubing is successfully loaded removed hands from 

tubing. 

 

    Ready to Load Tube            Tube Properly Loaded 

Refer to the following cable hook up guide and connection details below for installation of 

cables.  

Page 9: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

 

Page 10: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

 

1.8 Operation 

Manufacturer Operating Environment Requirements: 

Operating Temperature: 0C – 60C  Storage Temperature: ‐20C – 70C Relative Humidity: 5% – 95% non‐condensing 

Maximum Altitude: 10,000 feet 

 

 

 

 

 

 

 

Page 11: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

  

1.9 Cleaning and Maintenance 

Intelivalve Solenoid Pinch Valves are designed for normal spray down sterilization procedures 

and include internal splash seals that prevent fluid spray penetration. Normal biological 

sterilization procedures can be done to the exposed valve head surface areas that come in 

contact with the tubing (i.e. tube slot area).  

Some common sterilization solutions or methods that can be spray used at appropriate 

concentrations are: 

Ethanol (3‐5%) 

Methanol (3‐5%) 

Iso‐Propyl Alcohol (3‐5%) 

Hydrogen Peroxide (3‐5%) 

Ammonia (3‐5%) 

Bleach 

UV radiation exposure not exceeding 15 minutes 

 

With the authorization and training by Acro Associates, if routine maintenance outside of 

normal use is required for technical reasons, then an operator will be permitted to access 

certain areas of the product to perform limited maintenance in a safe, guided manner. This 

requires Acro Associates to train and certify that the user has been informed on how to access 

limited areas for safe maintenance.  

 

1.10 Troubleshooting 

Page 12: Intelivalve® Solenoid Pinch Valve - Acro Associates · Models Covered: 2100‐H‐AB*(or SS, WD, and BD)‐Vxxx (xxx means all numbers assigned) 2200‐H‐AB‐Vxxx 2300 ...

©2012 All rights reserved    Rev. A / May 2012 

 

In the event of pinch valve failure, the Acrosense FCP‐A controller board will provide a variety of 

flashing LED combinations that can provide the user with feedback.