Integrity All Ultrex Series Windows INSERT APPLICATION Measuring Instructions
-
Upload
patrick-white -
Category
Education
-
view
95 -
download
1
description
Transcript of Integrity All Ultrex Series Windows INSERT APPLICATION Measuring Instructions
![Page 1: Integrity All Ultrex Series Windows INSERT APPLICATION Measuring Instructions](https://reader035.fdocuments.us/reader035/viewer/2022081816/54bc92bc4a795913128b459d/html5/thumbnails/1.jpg)
Integrity All Ultrex Series WindowsReplacement Measuring Instruction
Before You BeginThese measuring instructions cover the followingproduct types: All Ultrex Casement (IFCA), AllUltrex Single Hung and Double Hung (IFSH andIFDH).
Before beginning installation be sure to inspect theexisting opening for any signs of rot, decay, orother deterioration. It is essential that all substratesand sheathing be solid and free from defects toensure proper installation. If the above conditions
are not met, please take corrective action andrepair and/or replace components as necessary.
Products are manufactured 1/2"(13) narrower inwidth and height than rough opening (R.O.).
It may be necessary to cover the resulting gap withtrim after installation.
NOTE: Numbers listed in parentheses () are metricequivalents in millimeters to the nearest whole number.
Required MeasurementsNOTE: Integrity All Ultrex units are built 1/2"(13) narrower and 1/2"(13) shorter than Rough Opening dimensionswhich are used for ordering in Order Management System (OMS). Add 1/8"(3) to inside opening width and 1/4"(6)to inside opening height to obtain the proper dimension to enter into OMS rough opening fields.
1. Inside Opening Width (A): Measure inside of frame at three locations: the sill, center of jambs, and headjamb. Record the narrowest measurement.
NOTE: Do not measure width from parting stops, blind stops, hardware, or weather strip.2. Inside Opening Height (B): Measure inside of frame at three locations: left side, center, and right side. Record
the shortest measurement.
3. Stool Height (C): (For use on Casement Installations only) Measure the stool height and record. If the stoolheight is over 1 7/16” modification to the existing sill may be necessary.
Recommended Measurements4. Measure the width of the blind stops from the inside opening to the edge of the blind stop (D). If width exceeds
1/2"(13), modification to the blind stop or an exterior installation may be necessary.
5. Measure Jamb pocket depth (E). If depth is less than 3 1/4"(83), modification to the pocket may be necessary.(Exterior installation is recommended for pocket depths less than 3 1/4".)
14 Degree Existing Sill Flat Existing Sill
12012-01-1219972219
Integrity All Ultrex Series WindowsReplacement Measuring Instruction
![Page 2: Integrity All Ultrex Series Windows INSERT APPLICATION Measuring Instructions](https://reader035.fdocuments.us/reader035/viewer/2022081816/54bc92bc4a795913128b459d/html5/thumbnails/2.jpg)
* If blind stop width exceeds 1/2" (13), modifications may be necessary.
** If less than 3 1/4" (83) or greater than 3 1/2" (89), modifications may be necessary.
Required Measurement Recommended Measurement
Window Number /Location
Product Description
A B C
Calculated R.O. for OMS
D ERO Width =A + 1/8”
RO Height = B + 1/4”
Site Map
Follow the steps on the previous page to fill inthis worksheet.
(A) Inside opening Width (narrowest width)
(B) Inside Opening Height
(C) Stool Height
(D) Blind Stop Width*
(E) Jamb Pocket Depth**
PROJECT
MEASURED BY:
DATE:
22012-01-1219972219
Integrity All Ultrex Series WindowsReplacement Measuring Instruction