Integrity All Ultrex Series Windows INSERT APPLICATION Measuring Instructions

2
1 2012-01-12 19972219 Integrity All Ultrex Series Windows Replacement Measuring Instruction Integrity All Ultrex Series Windows Replacement Measuring Instruction Before You Begin z These measuring instructions cover the following product types: All Ultrex Casement (IFCA), All Ultrex Single Hung and Double Hung (IFSH and IFDH). z Before beginning installation be sure to inspect the existing opening for any signs of rot, decay, or other deterioration. It is essential that all substrates and sheathing be solid and free from defects to ensure proper installation. If the above conditions are not met, please take corrective action and repair and/or replace components as necessary. z Products are manufactured 1/2"(13) narrower in width and height than rough opening (R.O.). z It may be necessary to cover the resulting gap with trim after installation. NOTE: Numbers listed in parentheses () are metric equivalents in millimeters to the nearest whole number. Required Measurements NOTE: Integrity All Ultrex units are built 1/2"(13) narrower and 1/2"(13) shorter than Rough Opening dimensions which are used for ordering in Order Management System (OMS). Add 1/8"(3) to inside opening width and 1/4"(6) to inside opening height to obtain the proper dimension to enter into OMS rough opening fields. 1. Inside Opening Width (A): Measure inside of frame at three locations: the sill, center of jambs, and head jamb. Record the narrowest measurement. NOTE: Do not measure width from parting stops, blind stops, hardware, or weather strip. 2. Inside Opening Height (B): Measure inside of frame at three locations: left side, center, and right side. Record the shortest measurement. 3. Stool Height (C): (For use on Casement Installations only) Measure the stool height and record. If the stool height is over 1 7/16” modification to the existing sill may be necessary. Recommended Measurements 4. Measure the width of the blind stops from the inside opening to the edge of the blind stop (D). If width exceeds 1/2"(13), modification to the blind stop or an exterior installation may be necessary. 5. Measure Jamb pocket depth (E). If depth is less than 3 1/4"(83), modification to the pocket may be necessary. (Exterior installation is recommended for pocket depths less than 3 1/4".) 14 Degree Existing Sill Flat Existing Sill

description

 

Transcript of Integrity All Ultrex Series Windows INSERT APPLICATION Measuring Instructions

Page 1: Integrity All Ultrex Series Windows INSERT APPLICATION Measuring Instructions

Integrity All Ultrex Series WindowsReplacement Measuring Instruction

Before You BeginThese measuring instructions cover the followingproduct types: All Ultrex Casement (IFCA), AllUltrex Single Hung and Double Hung (IFSH andIFDH).

Before beginning installation be sure to inspect theexisting opening for any signs of rot, decay, orother deterioration. It is essential that all substratesand sheathing be solid and free from defects toensure proper installation. If the above conditions

are not met, please take corrective action andrepair and/or replace components as necessary.

Products are manufactured 1/2"(13) narrower inwidth and height than rough opening (R.O.).

It may be necessary to cover the resulting gap withtrim after installation.

NOTE: Numbers listed in parentheses () are metricequivalents in millimeters to the nearest whole number.

Required MeasurementsNOTE: Integrity All Ultrex units are built 1/2"(13) narrower and 1/2"(13) shorter than Rough Opening dimensionswhich are used for ordering in Order Management System (OMS). Add 1/8"(3) to inside opening width and 1/4"(6)to inside opening height to obtain the proper dimension to enter into OMS rough opening fields.

1. Inside Opening Width (A): Measure inside of frame at three locations: the sill, center of jambs, and headjamb. Record the narrowest measurement.

NOTE: Do not measure width from parting stops, blind stops, hardware, or weather strip.2. Inside Opening Height (B): Measure inside of frame at three locations: left side, center, and right side. Record

the shortest measurement.

3. Stool Height (C): (For use on Casement Installations only) Measure the stool height and record. If the stoolheight is over 1 7/16” modification to the existing sill may be necessary.

Recommended Measurements4. Measure the width of the blind stops from the inside opening to the edge of the blind stop (D). If width exceeds

1/2"(13), modification to the blind stop or an exterior installation may be necessary.

5. Measure Jamb pocket depth (E). If depth is less than 3 1/4"(83), modification to the pocket may be necessary.(Exterior installation is recommended for pocket depths less than 3 1/4".)

14 Degree Existing Sill Flat Existing Sill

12012-01-1219972219

Integrity All Ultrex Series WindowsReplacement Measuring Instruction

Page 2: Integrity All Ultrex Series Windows INSERT APPLICATION Measuring Instructions

* If blind stop width exceeds 1/2" (13), modifications may be necessary.

** If less than 3 1/4" (83) or greater than 3 1/2" (89), modifications may be necessary.

Required Measurement Recommended Measurement

Window Number /Location

Product Description

A B C

Calculated R.O. for OMS

D ERO Width =A + 1/8”

RO Height = B + 1/4”

Site Map

Follow the steps on the previous page to fill inthis worksheet.

(A) Inside opening Width (narrowest width)

(B) Inside Opening Height

(C) Stool Height

(D) Blind Stop Width*

(E) Jamb Pocket Depth**

PROJECT

MEASURED BY:

DATE: