Integrating Profibus and Modbus devices in your Rockwell...

16
Copyright © 2007 Rockwell Automation, Inc. All rights reserved. Integrating Profibus and Modbus devices in your Rockwell Architecture Tony Milne Regional Development Manager, EMEA

Transcript of Integrating Profibus and Modbus devices in your Rockwell...

Page 1: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved.

Integrating Profibus and Modbus devices in your Rockwell Architecture

Tony MilneRegional Development Manager, EMEA

Page 2: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 2

Objectives

• To show integrators how easily Profibus and Modbus devices and networks can be integrated into Rockwell’s Integrated Architecture

• To discuss the meaning, and the benefits, of Integrated Architecture– To end-users– To system integrators

• To specify the issues facing integrators of legacy protocol devices

• And to list the ways in which Molex and Rockwell together can overcome any problems

Page 3: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 3

Integrated Architecture

• Integrated means that the end-user sees one system

– Operators are trained once– Maintenance is provided from a single

source– Engineering tools and operating

interfaces work together– Look & feel is maintainedCustomer

Satisfaction

IntegratedArchitecture One-stop-shop

One knowledge base

Page 4: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 4

Customer Requirements

• Potential buyers of Rockwell software, Automation and Control hardware, and Networks, also want to include other devices

– How do they install, communicate and manage the devices, and the data they produce ?

– How do they support the legacy protocols that often come with them ?

Customer Satisfaction

LegacyProtocols

Use bestor Specialist

Devices

MaintainExisting

Infrastructure

Page 5: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 5

Problems to resolve

• End-Users want to keep existing infrastructure

– To save costs• Avoid new CAPEX• Avoid labour to change

– To minimise risk• If it’s not broke, don’t change it

• System integrators want to use known, tested architectures

– Supplier relationships– Training of employees

• Some solutions are only available with a limited protocol range

• Some protocols are ‘mandated’ or adopted as standards by industry, trade groups, safety or advisory bodies

• Some protocols become de facto standards by their success

Wide range of manufacturers

Ubiquitous Rockwell Software

Installation

Support

Page 6: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 6

Meeting the Needs

• Molex is an expert in industrial protocols– Gateways, PC cards

• Rockwell asked Molex to provide Profibus and Modbus solutions

• Molex integrated the device networks into Rockwell Architecture

– Configuration and diagnostic through AB RSLinx™ (RLL) or local Serial port

– Possible to change the ControlLogixConfiguration while the PROFIBUS Scanner is online

– Possible to change the Profibus Configuration while CPU is RUN mode

• Use Molex tools or Rockwell toolsWide range of Legacy Protocols

RLL integration

Configuration

Diagnostics

Page 7: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 7

RLL mode advantage

Ex

DP

PA

EtherNet/IP ControlNet

Profibus DP-V1

RLL Feature

• Fully integrated into Rockwell Architecture

• Remotely configure and diagnose PROFIBUS devices

• Very important for Process Control: Maintenance don’t have to go into the plant or Ex zone

Page 8: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 8

Remote Access (RLL)

Modbus Serial Master

Modbus TCP&UDP Client and Server

Rockwell Networks(Ethernet, ControlNet, …)

Monitoring Station Maintenance Station

Rockwell RSLinx

• Full integrated into Rockwell Architecture• Remotely configure and diagnose devices

Modbus Serial Slave

RLL Feature

BradCommunications Software

Page 9: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 9

Rockwell PROFIBUS FDT Architecture in Process Industry

DP

PA

Profibus DP-V1Speed 93.5Kbps or 45.45Kbps

Profibus PASpeed 37.5Kbps

DP/PA Coupler

FDT Frame application + commDTM + DeviceDTM runs over TCP connection

Monitoring Station

Ex

EtherNet/IP

ControlLogix Backplane

RLL Feature

Rockwell RSLinx Pro to set up TCP connection

HART

Page 10: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 10

Roadmap

• Add existing protocol portfolio

Client/ServerSimatic S5, S7 and TI-505Industrial Ethernet TCP

TSX Micro, Premium

C, CV, CS

A and Q

GE90-30,GE90-70

Alspa C80-35, C80-75

AL2000 and webgate

PLC Series

Client/Server

Client/Server

Client/Server

Client/Server

Client/Server

Client/Server

Access

SIEMENS

Uni-TE TCPSCHNEIDER ELECTRIC

FINS TCPOMRON

MelsecMITSUBISHI ELECTRIC

SRTP GE FanucGE FANUC

SRTP CegelecCEGELEC

ALNET IIALTUS

ProtocolPLC Manufacturer

ET

HE

RN

ET

ET

HE

RN

ET

MasterSysmacSysmac WayOMRON

MasterPS32, PS316SucomaMOELLER

MasterGE90-xx, 80-xxSNPXGE FANUC

Master2000, 5000, Supervisor 2000Data LinkELSAG BAILEY

MasterSimatic S53964/3964R

MasterTI-505TI DirectTEXAS INSTRUMENTS

MasterPLC-5 and SLC 500DF1ALLEN BRADLEY

MasterSimatic TI-505TI-Dir

MasterSimatic S7-200PPI/PPI+

Simatic S5

TSX 7, Premium

PCD

Master

M/S, C/S

Master

AS511SIEMENS

UnitelwaySCHNEIDER ELECTRIC

S-BusSAIA BURGESS

SE

RIA

LS

ER

IAL

Page 11: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 11

SST Communication modules for Rockwell PLCs

SST Comm. Module for CompactLogix, 1* Profibus DP (available end 2009)tbaProfibus

PDFSST Comm. Module for SLC, 2 channel ASi MasterSST-ASI-SLCAS-iSLC500

PDFSST Comm. module for ControlLogix, 1*Eth. port, 2*RS232/485 serial ports, with Remote Link Library

NEWSST-ESR2-CLX-RLL

Ethernet+ Serial

PDFSST Comm. module for ControlLogix, 4* RS232/485 serial ports, with Remote Link Library

NEWSST-SR4-CLX-RLLSerial

SST Comm. Module for CompactLogix Modbus TCP and RTU/ASCII (start 2010)

SST Comm. Module for SLC, 1* Profibus DP

Update FDT/DTM sw license for Profibus DP SST Comm. Module for ControlLogix (firmw.+CommDTM)

SST Comm. Module for ControlLogix, 1* Profibus DP Mstr V0/V1 & slv +CommDTM + RLL

SST Comm. Module for ControlLogix, 1* Profibus DP Mstr V0/V1 & slv + Remote Link Library

Description

Modbus

Profibus

Profibus

Network

CompactLogix

ControlLogix

AB PLC family

PDFSST-PFB-SLC

PDFSST-PB3-CLX-DTM

PDFSST-PB3-CLX-DTS

PDF

PDF Link

tba

SST-PB3-CLX-RLL

Ordering Part Number

View Communication module on the web

Page 12: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 12

Cost Analysis

• Financial benefits – Less risk– Reduced capital investment – Ability to use common devices for all developments

• Leverage ease-of-use of Rockwell solutions to competitors’ installations• Improve ROI on training and tools investment• Better performance compared gateways

– Direct connection on backplane– Clear lines of support

• Encompass products always supported by Rockwell• Support from a single source – Rockwell engineers know the products• Software integrated• Advanced diagnostics

Page 13: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 13

Molex expertise

IntegratedIntegratedArchitectureArchitectureIntegrationIntegration

RLLRLLFD

TFD

T

RSLogix

RSLogix

TCP/

IPTC

P/IP

ConfigurationConfiguration& Diagnostics& Diagnostics

Devic

es

Devic

es

ScannerScanner

Acy

clic

Acy

clic

CyclicCyclic

Parameters

Parameters

ProtocolsProtocols

Profibus

Profibus

Mod

bus

Mod

bus

60 Others

60 Others

Page 14: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 14

Key Benefits

• End-user or integrator can choose the software solution and the PAC supplier independently of the IO/Fieldbus requirements– Legacy devices and cabling can be kept

• Maintain initial investment• Reduce risk of changing network or devices• Use of best-of-class, instead or best-available-with-DeviceNet

– Expertise is maintained• Investment in training of personnel• Suppliers• Maintenance process, quality

• Operations controlled seamlessly through Rockwell software– Legacy device network/fieldbus transparent to user

• Easy to set up, install, manage, diagnose

Page 15: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 15

Conclusive comments

• If you identify a legacy protocol installed or needed, and it does not appear to be on our list, let me know.

• Work with your Rockwell partners to integrate • If you have a competitive situation against Mitsubishi, Siemens, GE etc,

and you need price support – ask your Rockwell contacts to contact us through Sébastien Bonnes

Page 16: Integrating Profibus and Modbus devices in your Rockwell ...ucc.colorado.edu/allen-bradley/PPT_LW_LT5.pdf · networks can be integrated into Rockwell’s Integrated Architecture •

Copyright © 2007 Rockwell Automation, Inc. All rights reserved. 16

Q&A

• to – Tony Milne, Molex– +33 626 640 006– [email protected]

• Booth visit