Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents...
-
Upload
byron-mitchell -
Category
Documents
-
view
217 -
download
0
Transcript of Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents...
![Page 1: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/1.jpg)
Integrated Approaches
Orientation
Shading: vertical & extended
Natural ventilation: roof vents
Forced ventilation
Evaporative cooling
Pad and fan system
Multi-layer nets with fan system
![Page 2: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/2.jpg)
E
W
S
N
sun rise
sun set
Solar noon
Track of Sun
E-W orientation to minimize direct sunlight
![Page 3: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/3.jpg)
Most of the Diary barns in Taiwan are the open structure type with 4 ends open.
Before shading
![Page 4: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/4.jpg)
Known FactsTaiwan is at Northern Hemisphere in between 20 – 25 deg. Latitude.
N S N
E
W
6/21
9/2112/219/21
3/21, 6/21
12/21
3/21
![Page 5: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/5.jpg)
West end extended shading
South end extended shading
North end vertical shading
![Page 6: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/6.jpg)
After shading: almost no direct sunlight into the dairy barn
![Page 7: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/7.jpg)
Tall buildings need side shading the most
9/219/21
![Page 8: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/8.jpg)
Two types of side shading
![Page 9: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/9.jpg)
With proper design
Tall building with eve height > 3.5 m is not necessary.
![Page 10: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/10.jpg)
Natural Ventilation : roof_1
![Page 11: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/11.jpg)
T, h and ratio of opening area are critical factors in natural
ventilation
Large opening area / small opening area
% o
f in
crea
se a
ir f
low
rat
e
![Page 12: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/12.jpg)
< 3 m
Natural Ventilation :roof_2
Wind , T and h (Chimney effect) are governing factors
Wind driven rotator/roof vent small h
increasing h
![Page 13: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/13.jpg)
Propeller inside to enhance up-flow air movement
Some without propeller and some install it in wrong orientation
![Page 14: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/14.jpg)
Wrong color
Painted black, Absorbing heat as much as possible to enhance the chimney effect by increasing T.
![Page 15: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/15.jpg)
Natural Ventilation :roof_3
•Double skins porous roof
Roof with many small holes is superior than roof with some big holes even when the total opening
area are the same.
![Page 16: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/16.jpg)
Patented double skins porous roof
Can be recycle, environmental friendly.Non-flammableUniform openings throughout entire roof.Air within double skins become thermal barrier.Heated air within double skins enhance natural convection. No odd looking appearance compare with
![Page 17: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/17.jpg)
Comparison of 3 types of roof materials
Can be recycle. Non-flammable
More expensive. Can not recycle. Flammable.
Porous roofRegular
PU added
![Page 18: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/18.jpg)
Forced Ventilation
Titled Fan will draw down the hot air from the upper portion under roof
![Page 19: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/19.jpg)
High pressure fogging with movable fans
![Page 20: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/20.jpg)
Design criteria
Intermittent high pressure foggingTo reduce air temperature at the top portion under roofReducing downward radiationPrevent the fan from drawing hot airEnhance air movementShould not increase the RH around cattle
Movable fansReduce # of fans requiredProvide varying air velocityBlow to the necks of the cattle and the feeds
![Page 21: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/21.jpg)
Fogging directly to the cows
![Page 22: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/22.jpg)
![Page 23: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/23.jpg)
Intermittent spraying/forced ventilation has better cooling
effect compare with fogging fan
![Page 24: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/24.jpg)
Intermittent spraying/forced ventilationBerman Bucklin This study
Spraying 1 min 30 sec 1 min
Forced vent. 5 min 4.5 min 9 min
S/F Time ratio 1: 5 1: 9 1: 9
Replication 5 times 3 times 5 times
Duration 30 min 15 min 50 min
Interval 1-2 hrs 45 min 1-2 hr
Location Inside barn Inside barn & holding area
Holding area
![Page 25: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/25.jpg)
Intermittent spraying/forced ventilation
Strategies
Spray & vent5/10min3times
Spr+vent
5/10min3times
Spr+vent
3/12min3times
Spr+vent0.5/4.5mi
n
10 times
Spr+vent1/9min5times
Total Spray 15 min 15 min 12 min 5 min 5 min
Total Vent. 30 min 30 min 36 min 45 min 45 min
Spray/Vent 1 : 2 1 : 2 1 : 4 1 : 9 1 : 9
Duration per
treatment30 min 45 min 45 min 50 min 50 min
![Page 26: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/26.jpg)
Intermittent spraying/forced ventilation (cont.)
&: concurrent
+: alternating5&10
x3
5+10
x3
3+12
x3
0.5+4.5
x10
1+/ 9
x5Rectal Temp. reduction in 80 min
0.4 oC 0.4 oC 0.4 oC 1.2 oC 1.2 oC
Rectal Temperature recovery after treatment
0.4 oCper 30 min
0.4 oCper 50 min
Cooling effect
Rel.water consumption
Rel.Power consumption
Worst
3
1
poor
3
1
Good
2.4
1.2
best
1
1.5
best
1
1.5
![Page 27: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/27.jpg)
Before spraying
Average body Temperature:36.8 oC
![Page 28: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/28.jpg)
After Spraying + Venting
Should spray from both top and down
![Page 29: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/29.jpg)
Pad and Fan system
![Page 30: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/30.jpg)
Drawbacks of the pads
Rely on import, expensivealgae and Dirt
![Page 31: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/31.jpg)
Solution to prevent algae:
Coated Pad
![Page 32: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/32.jpg)
Search for the substitution of the traditional pads
Palm tree fibers
Stack of plastic cages
Stack of hollow bricks
![Page 33: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/33.jpg)
Patented Muti-Net to replace traditional pads
![Page 34: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/34.jpg)
Negative pressure type used in Greenhouses
![Page 35: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/35.jpg)
Positive pressure type used in Dairy barn
Fogging is better than misting
![Page 36: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/36.jpg)
Positive pressure type for non-air-tight dairy barns
![Page 37: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/37.jpg)
Nozzles in function
![Page 38: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/38.jpg)
Multi-Net fogging and fan vs. Pad and fan
Tdb: 32 oC
RH : 55 %
After_Pad
Tdb
Wind Velocity
m/s
Eff.
10cm Pads 26.37 oC 1.5-2.5 75 %
28.25 oC 8 - 10 50 %
6 layer Nets 25.0 oC 8-10(3 AC/min)
92.5%
![Page 39: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/39.jpg)
Conclusions
Genetic breeding, Nutrition and management were not mentioned. But are important as well.Cost Effective Integrated approaches:
Means with no energy consumption: 1st choiceOrientation, roof vent, shading
Means with high cooling effect but low cost:2nd choice
Intermittent spraying/vent, multi-net spraying and fan systemmulti-net fogging and fan system
![Page 40: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/40.jpg)
Cost effective Integrated Approaches
Approaches Installation Cost
East-West orientationDouble skin porous roofNorth side vertical shadingWest/South sides extended shadingIntermittent spray/ forced ventilationMulti-Net spraying and fansIntermittent fogging with tilted fixed fansMulti-Net fogging and fansPad and fanTilted Movable fans
low
![Page 41: Integrated Approaches Orientation Shading: vertical & extended Natural ventilation: roof vents Forced ventilation Evaporative cooling Pad and fan system.](https://reader033.fdocuments.us/reader033/viewer/2022051619/56649d9e5503460f94a8929b/html5/thumbnails/41.jpg)