Insulation & Multi-function Tester(LCD)Insulation & Multi-function Tester(LCD) 4101 IN 4102 MF...
Transcript of Insulation & Multi-function Tester(LCD)Insulation & Multi-function Tester(LCD) 4101 IN 4102 MF...
5F., NO.105, Jhongcheng Rd., Tucheng Dist., New Taipei City 23674, Taiwan (R.O.C.)
TEL: 886-2-22681528FAX: 886-2-22681529
e-mail: [email protected]
MEASURE WITH PRECISION
Insulation & Multi-function Tester(LCD)
4101 IN 4102 MFFEATURES Microprocessor-controlled. MeasuresInsulationResistance,voltage(AC-DC)measurements Automaticholdfacility. Continuitytestwithashortcircuitcurrentofminimum200mA. MOVandGasArresterTesting.(4102MF) Energyconservationisfeature.
EnerSave™limitsthetestdurationtoabout10Sec-ondstosaveenergy. Nomovingparts.Allcalibrationaresavedinternallyinanonvolatilememory. Easycalibrationatanyfacilityaroundtheworld. Lowcostmaintenance,calibration,andownership. Compliestoallthelatestregulations,includingUK.
FEATURES COMPARISON 4101 IN 4102 MFDigitalEECalibration(NoPotentiometers) KeypadOperation AutomaticVoltmeterAC/DCatStart/Reset ON-Reset/RestartKey OffPushButton(pressmorethan5Secon1kVkey) Auto-off TestON-OFF PolarizationIndex(PI)on250,500and1000V DielectricAbsorptionRatio(DAR)on250,500and1000V BatteryTest TestBatteryatStart TestBatteryatStartBatteryTestatSwitchON/Reset VoltmeteronrequestbyKeypad Automatic AutomaticSafetyVoltmeterbeforeeachTest Auto-DischargeonallTestandallRanges ContinuityShortCircuitCurrent>220mA(225mATypical) ContinuityOpenCircuitVoltageof5Vdc NominalVoltage@1mAonallInsulationRanges BuzzerON/OFF AlwaysON AlwaysONLeadsAuto-Nullkey TestAuto-Stop Re-programmableMicroprocessorforEasyUpdates CanbecalibratedinALLcalibrationlaboratories Insulationmeasurementfrom2kΩ(250Vrange)to8GΩ(1kVRange)
Continuityfrom0.01Ω(220mA)to1999Ω DCVoltmeterfrom±1Vdcto±950Vdc ACVoltmeterfrom1Vacto700Vac Accept8RechargeableBatteriesorAlkalineornormal SmartHold&StoponVoltmeterac/dc MOV/ProtectionDevicesTest GasArresterFunction EnerSave™
5F., NO.105, Jhongcheng Rd., Tucheng Dist., New Taipei City 23674, Taiwan (R.O.C.)
TEL: 886-2-22681528FAX: 886-2-22681529
e-mail: [email protected]
MEASURE WITH PRECISION
Insulation & Multi-function Tester(LCD)SPECIFICATIONS Insulation Test 4101 IN 4102 MFTestvoltage(DCV) 250V/500V/1000V 250V/500V/1000VOutputvoltage@1mA RatedtestVoltage+10%Max RatedtestVoltage+10%MaxMeasuringranges 0.2M~2G/0.2M-4G/0.2M-8GΩ 0.2M~2G/0.2M-4G/0.2M-8GΩ
Accuracy 0.2M~4GΩ:±3%rdg4GΩ~8GΩ:±5%rdg
0.2M~4GΩ:±3%rdg4GΩ~8GΩ:±5%rdg
Whenvoltageisconstant,Currentislimitedat 1.2mA 1.2mA
Shortcircuitcurrent 4mAMax. 4mAMax.
Continuity TestMeasuringranges 0.01-1999Ω 0.01-1999Ω
Accuracy0.01-100Ω:±1.0%rdg100-300Ω:±1.5%rdg300-1999Ω:±2.0%rdg
0.01-100Ω:±1.0%rdg100-300Ω:±1.5%rdg300-1999Ω:±2.0%rdg
Shortcircuitcurrent >220mA >220mAOpencircuitvoltage 5Vdc 5VdcResolution ±2counts ±2counts
VoltmeterACvoltage(Auto) 0-700V 0-700VDCvoltage(Auto) 0-950V 0-950VAccuracy ±1.5%rdg ±1.5%rdgResolution ±1V ±1V
MOV Test & GAS Arrester Test Testvoltage 5-1020VdcVoltageresultaccuracy ±3%rdgVoltageresultresolution ±2counts
ProtectionsOverload 700V(betweenallterminals)Overvoltage ClassIII-700VtowardsgroundFuse 500mA250V,(5×20mm),HBC,FastBlow
GeneralDisplay 2lines×16charactersLCDAuto-nullthreshold 5ΩBuzzerthreshold 3ΩFasttest 10SecLongtest 60SecWithPIandDARtestfunction 10MinLoadbatterytestcurrent About300mAOperatingtemperature 0°Cto40°CnotinfullsunStoragetemperature -10°Cto50°CDimensions 250(L)×190(W)×110(D)mmWeight(batteryincluded) Approx1460g.Powersource 1.5V(AA)×8
Safetystandard EN61010-1CATIII600VEN61326-1
AccessoriesInstructionmanualTestleadsShoulderbeltBatteries